RC-19-1246WINGERTER LABORATORIES, INC. Engineering Testing -Inspection Services 1820 NE 144th Street, North Miami, FL 33181 - TELEPHONE: 305-944-3401 CLIENT: GFE, Inc. PROJECT: Whimer Residence CONTRACTOR: PROJECT LOCATION: 960 NE 95th St., Miami Shores, FL FIELD DENSITY TEST fi�C-vs-I�-1Z�� FACSIMILE: 305-949-8698 REPORT NO: I ORDER NO.: 19-1333 TEST DATE: 8/14/2019 TIME IN: 09:30 AM INSPECTOR: Darnell Richard PAGE NO.: 1 of 1 P.O. #: PERMIT #: TIME OUT. 10:30 AM Description of 19688- Grey Sand with some Rock PROCTOR SUMMARY OF Material: DENSITY TEST INFORMATION RESULTS Retest Dry Probe Optimum Max. Dry Percent Percent Lab Field Fill Field Test Location: of Moisture Density Depth Proctor Moisture Density Field Compaction Test No. Test # Lift Lab No %) (PCF) (In. Lab No. % CF Com actio Re uirement Status Wooden beam footers: 1121 I F Footer right of staircase 9.6 110.3 6 19688 1 10.0 1 111.5 98.9 95.0 PASSED Remarks: Field density test was performed in accordance with ASTM D 2922. This report is submitted as the confidential property of the client. The original of this report was signed and sealed by the herein referenced Registered Engineer in accordance with Rule 61G15 - 18.011 of Florida Administrative Code. ,���t/tliiUli��, 3 G E.N's `Q�• , ;OQ �0 4484kespp — � C ;-ATE O 14 , C. t.ali '01VAtEI;; to a 111 . 100 Ily submitted, 2TER LABORATORIEP, O0A01 0 T. Flood, Jr., FiE. License No. 44847 9 WINGERTER LABORATORIES, INC. Engineering Testing .Jnspection Services 1820 NE 144th Street, North Miami, FL 33181 TELEPHONE:305-944-3401 FACSIMILE:305-949-8698 SOILS LABORATORY TEST REPORT PROCTOR TEST CLIENT: GFE, Inc. REPORT NO.: 1 PROJECT: Whimer Residence ORDER NO: 19-1333 CONTRACTOR: PERMIT NO.: LOCATION: 960 NE 95th St., Miami Shores, FL P.O. NO.: Sampled By: Darnell Richard Date Sampled: 08-14-19 Tested By: Michael Major Date Tested: 08-19-19 Visual Soil Description: GrLy Sand with some Rock Sample Location: Inplace Materials MOISTURE DENSITY RELATIONSHIP (PROCTOR) Lab No.: Test Specification Optimum Moisture %) Maximum Dry Density CF 19688 "MODIFIED" PROCTOR, ASTM D 1557-A 10.0 111.5 MOISTURE DENSITY RELATIONSHIP TEST RESULTS AND GRAPH jai; 110 105- 104 - 103- 9 10 11 12 MOISTURE CONTENT (PERCENT OF DRY WEIGHT) PARTICLE SIZE ANALYSIS Sieve Size: 3" 2 1/2" 2" 1 1/2" 1" 1 3/4" 1/2" 3/8" #4 % Passing 100.00 93.40 88.60 67.80 61.6(, Sieve Size: #10 #20 #40 #60 #80 #140 #200 Washed Dry % Passing 55.80 45.40 40.30 20.80 13.60 3.80 2.00 Remarks: ' 1 + Using the Unified Soil Classification System, the following terminology and definitiocsh��y� a 1ieg48 determine the percentages of A) GRAVEL B) SAND C) SILT or CLAY `�`� �P�.0 .. F<�Re'Spectfully submitted, 1) COARSE SAND: Passing No. 4 sieve minus that passing the No. 10.� Q ••'�O E lv J • 2) MEDIUM SAND: Passing No. 10 Sieve minus that passing No. 40..Z �: • �- F 'Vr �' GERTER LABORATORIES, INC. 3) FINE SAND: Passing No. 40 Sieve minus that passing No. 200. NO 44847 C) SILT OR CLAY: % of soil passing the No. 200 sieve. CL ) Donlild J. Flood, Jr., .E. S1 ' "flE OF Florida,License No. 44847 The original of this report was signed and sealed by the above Registered Profe�gonal.En6ineer in accordance with Rule 61G15-18.011 of the Florida Administration Code. As a mutual protection to clients, the public and ourselves, all reports are subMitted'as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports Is reserved pending our written approval.