RC-04-19-802 Comp testGEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES EG DYNATECH ENGINEERING CORP. WWW.ICY NATECliENGINEERING.COM Miami, July 1, 2021 Mr. Nicolas Brocherie THE OLIVINE GROUP HOME, INC. 293 NE 61" Street Miami, FL 33137 Re: Proposed Residence @ 123 NE 991h Street Miami Shores, FL Dear Mr. Brocherie: Pursuant to your request, Dynatech Engineering Corp. (DEC) performed a Compaction Test on July 1, 2021 at the above referenced project. DEC was authorized to perform a compaction test only. The purpose of our test was to determine the degree of compaction of the tested layer of material only. In no way shall a compaction test replace a demucking inspection, soil bearing capacity determination, or a pad certification. A soil boring test must be performed by client if not yet done, prior to construction to verify subsoil conditions. Underlying soils below test levels must be verified to prevent future settlements. (DEC) was not authorized to perform supervision and certification of the building pad preparation. This is not a pad certification. Our reports must be provided to all involved parties for their approval. Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on other areas or dates. Any subsequent site disturbances due to water erosion, rain, storm gutters discharging at footings, construction activities, excavations, overgrown, vegetation, traffic and other disturbances will void this test and the site must be re - compacted and re -tested prior to construction. Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils is required, we can provide a proposal for performing an environmental analysis of the soil materials. No other analysis is implied or warranted. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Enclosed find copies of the compaction test results. It has been a pleasure working with you and look forward to do so in the near future. ,��►"""'"''., Sincerely yours, Wissam Naamani. P. E. DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector No. 757 Certificate of Authorization No.: CA 5491 F' ` No. 39584 -o'-. STATE OF Qz. ,,,SIONALE�,,.. �"S11"I 1111100�� GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES �0EC DYNATECH ENGINEERING CORP. / WWW.DYNATECHENGINEERING.COM �48 MOISTURE -DENSITY RELATIONS OF SOILS PROCTOR COMPACTION TEST DATE: July 1 2021 CLIENT: THE OLIVINE GROUP HOME. LLC. PROJECT: Proposed Residence a., ADDRESS: 123 NE 99 h Street Miami Shores. FL CONTRACTOR: Latour Desien MATERIAL DESCRIPTION: Tan sand SAMPLED BY: WD TESTED BY: WD TEST RESULTS Sample Number 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop ASTM D-1557. % MOISTURE 4.9 6.7 7.9 12.0 DRY DENSITY 100 -1 102.8 105.2 104.6 Optimum Moisture 9.2 Percent 100% Maximum Dry Density 106.8 lbs./cu.ft. % Passing'/4" Sieve 96 Percent 108 106 104 102 100 98 Sampled By: WD 1 OS Led Fay: tiA�17 Checked By: ItIV lti'tSA+rkr� �•/��Ai '� h S 10 ' 12 14 C tl' ••.� E $•- q,� �.� Respectively subm ed. As a mutual prulcction to ctirnts, lire puhIic and ourselves. all reports ��;' �' �•••'• q t! {� arc submitted as the con fidcntial property ofelicnts, and authorisation _� �; a. 95g * --- !•nr u A. publication of sintements. eonclusions orcxtracis from or regark t _ ►'issam aamani, P.I.. our reports is reserved pending our written appmvai- — * �)YNATECH ENGINEERING CORP. STATE OF ; �� :171prida Reg. No. 39584 "� • F : �� : Certificate of Authorization No-: CA 5491 �4�rrin Is+t�t��� GEOTECHNICAL I ENVIRONMENTAL I 14ATERML.9 TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES oEG DYNATECH ENGINEERING CORP. 1NWW.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: July 1.2021 CLIENT: THE OLIVINE GROUP HOME. LLC. PROJECT: Proposed Residence na ADDRESS: 123 NE 991h Street Miami Shores FL CONTRACTOR: Latour Design Test No. I Location: East side of residence underslab Test No. 2 Location: West side of residence underslab Test No. 3 Location: Center of residence underslab Test No. 4 Location: North side of residence underslab Test No. 5 Location: South side of residence underslab Description of Material: Tan sand TEST NO. 1 2 3 4 5 DEPTH 12" 12" 12" 12" 12" FIELD DENSITY 105.2 105.6 105.3 105.8 105.1 MOISTURE CONTENT % 8.0 8.4 8.2 8.7 7.9 MAX. DENSITY IN THE FIELD % 98.5 98.9 98.6 99.1 98.4 COMPACTION REQUIREMENTS OF MAXIMUM 98% 98% 98% 98% 98% _ 100% MAXIMUM DENSITY (LAB) 106.8 106.8 106.8 106.8 106.8 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION RE QUIREMEN-1-S * Please note this is not a pad certification. A soil boring must be performed to determine subsoil conditions below the tested compaction layer prior to construction. �,,tttltllttlr�,r', >��' SAAD `rrrrrr Respectfully submitted, Tested By: WD %.4ti Checked By: AN yt ; No. 39584 * _Wissam N amani, P.E. -DYNATECH ENGINEERING CORP. STATE OF = Florida Reg. No. 39584 Certificate of Authorization No.: CA 5491 fONAION - *A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination. A soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves. all reports are submitted as the confidential property of clients. and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval.