RF-05-19-1130 UPLIFTederal Phone:954-784-2941 E-Fax: 954-784-7875 131ngineering admin@fed-eng.com www.fed-eng.com poes#i ng, Inc. Dated: Thursday, June 27, 2019 Order Number 19R442 KMR Roofing, LLC 10424 West State Road 84, Suite #10 Davie, FL 33324 RE: TAS-106 Tile Uplift Test Propos oo : u chins Perm �F-05-19-1130 1225 NE 93rd-Str Miami Shores, FL 33138 In accordance with your authorization, Federal Engineering & Testing, Inc. has performed Tile Uplift Testing in compliance with Testing Application Standards TAS-106 and the FloridaBuilding Code High Velocity Hurricane Zone on June 26, 2019 at the above referenced project. The purpose of our inspection was to determine the uplift capacity of the roof tiles for the residence at the above referenced project. The subject roof consisted of Flat Concrete Tile Foam Set. The pitch of the subject roof is 4/12. Our field engineer visited the site and conducted 71 uplift tests on the roof tiles. All tests were performed according to the Florida Building Code High Velocity Hurricane Zone and protocol TAS-106 using an Intercomp Scale Model CS200. The following is a summary of results: Field Test Results Test Number Test Location Field Uplift Pull Test Test Results 1 - 18 Corner See Attached Diagram 35 ± 5 Pounds Passed 19 - 48 Perimeter See Attached Diagram 35 ± 5 Pounds Passed 49 - 63 Field See Attached Diagram 35 ± 5 Pounds Passed 64 - 71 Hip/ Ride See Attached Diagram 35 ± 5 Pounds Passed All test results were found to be in compliance with TAS-106 and the Florida Buddin.9 Code The test results are limited to the tested areas. If other roof areas exhibit different conditions, it should be brought to our attention for remedial work. This uplift test is not a roof top inspection. A final roof inspection must be conducted by the building official for approval. The test results presented reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing due to exposure to the elements. Federal Engineering & Testing, Inc. is an independent third party providing un-biased testing information and results and is not affiliated with our client nor do we have any financial interest in the project or determination of the test resuits. As -mutual protection I., ulmhts, the pub!-.*--- ail-repeii6 property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. We appreciate the opportunity to be of service to you at this phase of your project. If you have any questions or commer,is, please- give us a call. It has been a pleasure working with you and look forward to doing so again in the near future. '3!'rcerely, w KziiFZeBlanc, P.E. Federal Engineering a Testing, Inc. F16ride Reg. No, 59,494 Certificate of-Authoriz'atie.. # 5471 Miami -'Cade Counby Certification # 18-1105.02 ,, 60 , HIAM FDOTT -®�n f. a= 0. 1 (w) = 0. 1 ( 74 ') = 7.4' a= 0.4 (h)= 0.4( 20 ') = 8 ' - Perimeter Dimensions = 4 ' Figure R301.2(7) Component & Cladding Pressure Zones Corner Area: 288 S.F. = 18 tests Perimeter Area: 748 S.F. = 30 tests ,Field Area: 1964 S.F. = 15 tests Ridge Caps: 153 = 8 tests Total Tests Performed: = 71 ,J [Y ederal ngineering & "esting, Inc. v N *All dimensions are approximate* Test Location Sketch Federal Engineering $ Testing Inc. 3370 NE 5th Avenue, Oakland Park, FL 33334 Client: KMR Roofing, LLC Project: Proposed Roof: Hutchinson Test: TAS-106 Tile Uplift Test Project Address: 1225 NE 93rd Street (Test location sketch is not to scale) Miami Shores, FL 33138