RCRT-7-15-1948Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Project Address
1280 NE 105 Street
Miami Shores, FL 33138-
Owner Information
COUNTRY CLUB VILLAS OF MIAMI
Permit No. RCRT-7-15-1948
Permit Type: 40 Yr ReCertification
Permit
Work Classification: ReCertification
Permit Status: APPROVED
Issue Date: 5/10/2018 1 Expiration: 1 ° 06/2018
Parcel Number
1122320270120
Block: Lot:
Address
1280 NE 105 Street
MIAMI SHORES FL 33138-
2135 ARCH CREEK Drive
MIAMI FL 33181-
Contractor(s) Phone Cell Phone
HOME OWNER
Fees Due
Amount
40 Yr Recertification Fee
$250 00
40 Yr ReCertification Fee
$900 00
Miscellaneous Fee
$80 00
Total:
$1,230.00
Applicant
COUNTRY CLUB VILLAS OF MIS
Phone Cell
(305)219-3762
Valuation: $ 0.00
Total Sq Feet: 0
Pay Date Pay Type Amt Paid Amt Due
Invoice # RCRT-12-15-58086
05/10/2018 Credit Card $ 980.00 $ 0.00
Invoice # RCRT-7-15-56568
12/11/2015 Check #: 4226998� $ 250.00 $ 0.00
HvauaDie inspections:
Inspection Type:
Final PE Certification
40 notification sent
PE Certification Letter
Review Electrical
Review Electrical
Review Electrical
Review Electrical
Review Building
Review Building
Review Structural
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zonln ermore, I authorize the above -named contractor to do the work stated.
ce)t2 7c�� May 10, 2018
Authorized Signature: Owner / Applicant / Contractor / Agent Dare
Building Department Copy
May 10, 2018
1
BUILDING
PERMIT APPLICATION
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
FBC 20 C
Master Permit No.y C (ZT 1 1 J— I g
Sub Permit No.
❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: !� ► " L S S A-
Folio/Parcels?►: Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder):�ne
Address:
City:
Tenant/Lessee Name:
Email: r, eev LLB
CONTRACTOR: Company Name:
Address:
City:
Qualifier Name:
State Certification or Registration #:
DESIGNER: Architect/Engineer:
Address:
Value of Work for this Permit: $
Type of Work: ❑ Addition
Description of Work:
❑ Alteration
Specify color of color thru tile:
Submittal Fee $
Scanning Fee $
Technology Fee $`
Structural Reviews $
(Revised02/24/2014)
State: Zip: �7 (
Phone#: l [, o
hone#:
Phone#:
Certificate of Competency #:
Phone#:
City: State: Zip:
Square/Linear Footage of Work:
❑ New ❑ Repair/Replace ❑ Demolition
a
Permit Fee $ _ CCF $_
Radon Fee $ DBPR $
Training/Education Fee $
CO/CC $
Notary $
Double Fee $
Bond $
TOTAL FEE NOW DUE $
�� OFFICE OF THE PROPERTY APPRAISER
Summary Report
Property Information
Folio:
11-2232-027-0120
1280 NE 105 ST
Miami Shores, FL 33138-2146
MIAMI SHORES VILLAS LLC
Property Address:
Owner
Mailing Address
PA Primary Zone
724 NE 79 ST
MIAMI, FL 33138 USA
3000 MULTI -FAMILY - GENERAL
0303 MULTIFAMILY 10 UNITS PLUS
MULTIFAMILY 3 OR MORE UNITS
Primary Land Use
Beds / Baths / Half
16 / 16 / 0
Floors
2
Living Units
16
Actual Area
Sq.Ft
Living Area
Sq.Ft
9,817 Sq.Ft
Adjusted Area
Lot Size
27,200 Sq.Ft
1955
Year Built
Assessment Information
Year
2017
2016
2015
Land Value
$537,200
$537,200
$537,200
Building Value
$622,800
$612,800
$532,800
XF Value
$0
$0
$0
Market Value
$1,160,000
$1,150,000
$1,070,000
Assessed Value
$1,160,000
$1,150,000
$1,065,557
Benefits Information
Benefit Type
2017
2016
2015
Non -Homestead Cap Assessment Reduction
$4,443
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
IShort Legal Description I
ANCO SUB PB 53-54
LOTS 1-B & 2-B
LOT SIZE 27200 SQUARE FEET
OR 15856-2309 0393 1
COC 22315-3981 02 2004 6
Generated On : 5/3/2018
Taxable Value Information
20171
2016� 2015
County
Exemption Value
$0
$0
$0
Taxable Value
1 $1,160,000
$1,150,000
$1,065,557
School Board
Exemption Value
$0
$0
$0
Taxable Value
$1,160,000
$1,150,000
$1.070,000
City
Exemption Value $0 $0
$0
Taxable Value 1 $1,160,000 $1,150,000
$1,065,557
Regional
Exemption Value $0
$0
$0
Taxable Value $1,160,000
$1,150,000
$1,065,557
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
01/24/2018
$1,850,000
30847-1498
Qual by exam of deed
09/19/2011
$1,100,000
27833-1191
Qual by exam of deed
02/01/2004
$343,000
22315-3981
Other disqualified
03/01/1993
$445,000
15856-2309
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property
Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamid ade.gov/info/disclaimer.asp
Version:
Dori:;:c:r: ,... C,: �ir•;:r;;:-•au:;
1r�
Sorg
�r/'M J �'.'is
�r_f ��?s oaF�a� 1�af .��cti'. F�f �1=rrr�?c� ;,,,•f,•�,t.�
DetwMerk of State / Division of Cornnrations / $eBrGh RecafK-k / De!_sll BkQncun�enl Numb,- /
Detail by Entity Name
Florida Limited Liability Company
MIAMI SHORES VILLAS, LLC
Filing Information
Document Number
L18000009411
FEI/EIN Number
NONE
Date Filed
01/10/2018
State
FL
Status
ACTIVE
Principal Address
724 N.E. 79 STREET
MIAMI, FL 33138
Mailing Address
724 N.E. 79 STREET
MIAMI, FL 33138
Registered Ag€nt Natme_& Address
REITER, CORY
724 N.E. 79 STREET
MIAMI, FL 33138
Authorized Persons Detail
Name & Address
Title MGR
REITER, CORY
724 N.E. 79 STREET
MIAMI, FL 33138
Annual Reports
No Annual Reports Filed
11110( 1 Florida United iability Vicw image in PDF tonnat
http://search.sunbiz.org/Inquiry/CorporationSearchISearchResultDetail?inqui rytype=EntityName&directionType=lnitial&searchNameOrder=M IAM ISHORESVI.. 1/2
1280 NE 105th Street
A.IEDF„ INSPE
November 30, 2015
Building Official
City of Miami Shores
10050 NE 2 Avenue
Miami Shores Village FL 33138
Allied Building Ins ection Services
Inspections . Testing. Engineering
RE: 40-Year Building Re -Certification Inspection Reports
SUBJ: 1280 NE 105th Street, Miami Shores, FL 33138 r ;, WI � � T ,
Folio: 11-2232-027-0120 —Bldg. 1
Dear Building Official,
Enclosed, ase find the structural and electrical reports iL
office. The building is structurally safe for its intended us�
compliance with section 8-11(F) of the Miami Dade Coun-t
building is also electrically safe for its use and present occup
Code & Miami Dade County Chapter 8C-3. (Parking illumily
attached hereto.) Please allow this letter to serve as out i
MIAMI SHORES VILLAGE
APPROVED BY DATE
he_fDma�dIlag fired bar J
3,% es Itative
nt occupancy, inAdminisCode h
IRT&F r Florid 'ding j
Lion is ce iffed bt others. !
noted subject property.
As a routine matter, in order to avoid possible misunders�aM"1,Nl
should be construed directly or indirectly as a guarantee for any poi
To the best of my knowledge and ability, this report repre'��H+i
.
9
the present condition of the building.
P,LDG.
Sincerely, r
OF FQ)
Allied Building Inspection Services, Inc. ,.ice ;d.!�rE
e '
AR0017521
AA
y
Mark Reardon, RA 0017521
11A
g in this
appraisal of
3 COMPL;ANC:E WITH ALL FEDERAL
� OUN1Y RULES AND REGULATIONS
8203 SW 1241h Sfreel. Miami, Florida 33156 * Tel: (305; 23=4-7 377 * Fa:.: (305) 234-7664
990
1280 NE 105th Street
Allied Buildin Iris ection Services
Inspections .Testing. Engineering
Minimum Inspection Procedural Guidelines for
Building Structural Re -Certification
1. Description of Structure
a. Name of Title: HMT Country Club Villas
b. Street Address: 1280 NE 105th Street, Miami Shores, FL 33138
c. Legal Description: Anco Sub PB 53-54 Lots 1-B & 2-B
d. Owner's Name: HMT Country Club Villas c/o David Hall
e. Owner's Mailing Address: 2135 Arch Creek Dr., Miami, FL 33181
f. Building Official Folio Number: 11-2232-027-0120 (Bldg. 1)
g. Building Code Occupancy Classification: R2
h. Present Use: Multifamily Residential
i. General Description, Type of Construction, Size, Number of Stories, Special Features: 2-Story
CBS & Reinforced Concrete Structure. Approximately 9,817 S.F.
j. Additions to original structure: None noted (no plans available on site).
2. Present Condition of Structure of F� oR�Oq
a. General alignment (note good, fair, poor, explain if significant) S ra Rearao
1. Bulging: Good y,, ez ,,,1
2. Settlement: Good
3. Defections: Good
4. Expansion: Good
5. Contraction: Good
b. Portions showing distress (note beams, columns, structural walls, floors, roofs, othe
Noted.
c. Surface conditions - describe general conditions of finishes, noting cracking, spalling, peeling,
signs of moisture penetration & stains: No spalling or significant cracks noted. No moisture
penetration noted.
d. Cracks - note location in significant members. Identify crack size as "Hairline" if barely
discernible; "Fine" if less than 1 mm in width; "Medium" if between 1 - 2 mm in width; "Wide" if
over 2 mm: Hairline and fine cracks in CBS walls, not significant.
e. General extent of deterioration - cracking or spLI:ing of corcre`_e or masonry; oxidation of metals;
rot or borer attack in wood: No spalling or signiffcant tucks natid.
f. Previous patching or repairs: Some minor stucco anu plaster patches noted, satisfactory.
g. Nature of present loading - indicate residential, commercial, other estimate magnitude:
- 7 -
8203 SW 1241h Street, Miami, Florida 3315t, * Tel • (305) 234-7377 * Far: (303) 234-7664
1280 NE 105th Street
A_llied_Buildin_g Inspection Services
Inspections. Testing. Engineering
3. Inspections
a. Date of notice of required inspection: Unknown
b. Date(s) of actual inspection: 11/24/15
c. Name and qualification of individual submitting inspection report:
Mark Reardon, RA 0017521
d. Description of any laboratory or other formal testing, if required, rather than manual or visual
procedures: Only manual hammer sounding of concrete.
e. Structural Repair (note appropriate line):
1. None required: None Required.
2. Required (describe and indicate acceptance): None Required.
4. Supporting Data
a. sheets written data 0
b. photographs (see attached)
c. drawings or sketches 0
5. Masonry Bearing Walls (indicate good, fair or poor)
a.
Concrete masonry units:
Good
b.
Clay tile or terra cotta units:
NIA
c.
Reinforced concrete tie columns:
Good
d.
Reinforced concrete tie beams:
Good
e.
Lintels:
NIA
f.
Other type bond beams:
NIA
g.
Masonry finishes - exterior:
1. Stucco:
Good
2. Veneer:
Good
3. Paint only:
NIA
4. Other (describe):
NIA
h.
Masonry finishes — interior:
1. Vapor barrier:
NIA
2. Furring and plaster:
Good
3. Paneling:
NIA
4. Paint only:
NIA
5. Other (describe): Good, Gypsum Board
-3-
8203 SIF 12-11h Shreel. Miami, Florida 33156 * Tel: (3,)5; 23-l-377 * Fax: (305) 23-1-766-4
1280 NE 105th Street
A 1 ED
INSPECTIONSEE2'0CES
Allied Building Inspection Services
Inspections . Testing. Engineering
i. Cracks:
1. Location (note beams, columns, other): CBS Walls.
2. Description: Hairline and fine cracks, not significant
j. Spalling:
1. Location (note beams, columns, other): None Noted.
2. Description: N/A
k. Rebar corrosion (check appropriate line):
1. None visible: None Visible.
2. Minor -patching will suffice: N/A
3. Significant -but patching will suffice: N/A
4. Significant -structural repairs required (describe): N/A
I. Samples chipped out for examination in spalled areas:
1. No: N/A
2. Yes (describe color texture, aggregate, general quality): NIA
6. Floor and Roof Systems
���+Cr,
Ltd Rpara
<
,
41
po
s
a. Roof: 11 1
1. Describe (flat, slope, type roofing, type roof deck, condition):2:12 sloped roof w/ clay tiles
over wood deck; in good condition.
2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment
& condition of supports: None
3. Note types of drains & scuppers: None.
b. Floor system(s):
1. Describe (type of system framing, material, spans, condition): Concrete floor slabs on -
grade and above grade; in good condition.
c. Inspection - note exposed areas available for inspection, and where it was found necessary to
open ceilings, etc. for inspection of typical framing members: Limited view of framing through
scuttle.
7. Steel Framing Systems
a. Description: Columns at exterior walkways
b. Exposed steel: describe condition of paint & degree of ^orrosion: Palpt is good; corrosion is
insignificant.
c. Concrete or other fireproofing - note any cracking or spallir,g, i iota where any covering was
removed for inspection: NIA.
d. Elevator sheave beams & connections, anJ machine `loor oeams (note condition): NIA
-4-
S203 SW 124lh Slreel, Miami, Florida 33156 * 7 !: (305) 221-7377 * Fcr_•:: (305) 234-7664
1280 NE 105th Street
Allied Building Inspection Services
Inspections .Testing. Engineering
8. Concrete Framing Systems
a. Full description of structural system: Continuous pad footings, slab -on -grade, tie -columns,
tie -beams, stairs.
b. Cracking:
1. Not significant: Not significant.
2. Location & description of members affected & type cracking: Fine & hairline, CBS walls
only
c. General condition: Good Condition.
d. Rebar corrosion (check appropriate line):
1. None visible: None Visible.
2. Location/description of members affected & type cracking: NIA
3. Significant but patching will suffice: NIA
4. Significant - structural repairs required (describe): NIA
e. Samples chipped out in spalled areas:
1. No: N/A
2. Yes (describe color, texture, aggregate, & general quality): N/A
9. Windows
a. Type (wood, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted,
fixed, other): Metal jalousie, awning.
b. Anchorage - type & condition of fasteners and latches: Screws; Fair.
c. Sealants -type & condition of perimeter sealants & at mullions: Caulking; Fair.
d. Interior seals -type & condition at operable vents: Vinyl strips; Fair.
e. General condition: Fair.
10. Wood Framing
a. Type - fully describe if mill construction, light construction, major spans, trusses: Roof is of
conventional framing — 2x rafters/joists, 16" O.C. -12' to 14' spans, in fair condition; Walls
are load -bearing and non -load -bearing partitions — 2x studs, 16" O.C.
b. Note metal fittings (i.e. angles, plates, bolts, split pintles, pintles, other) and note condition: _
None.
�DFF �;
c. Joints - note if well fitted and still closed: Good &�- ' " `
d. Drainage -note accumulations of moisture: None J�' � Edward Re,,,,ao .
e. Ventilation - note any concealed spaces not ventilated: Good
f. Note any concealed spaces opened for inspection: Nude
AR0017521
al
i \''LL77 VV-' YiJ f_J
N203 SW 1 41h Slreel. Miami. Florida 33156 * 7-,/: (305; '_'4-7377 * Frr_:: (305) 234-7664 �
1280 NE 105th Street
Allied Buildinq Inspection Services
Inspections . Testing. Engineering
Minimum Inspection Procedural Guidelines for
Building Electrical Re -Certification
Inspection Commenced Inspection Made By:
Date: November 24, 2015
Signature: AF�Lopq,�
Print Name: Mark Reardon �• ` �,�acd Reardo•,
Inspection Completed
Date: November 30, 2015 Title: RA 0017521
'P�pp1�5�1 v
Address: 8203 SW 124 Street'.
Miami, Florida 33158 _ s � �gG
1. Description of Structure
a. Name of Title: HMT Country Club Villas
b. Street Address: 1280 NE 105th Street, Miami Shores, FL 33138
c. Legal Description: Anco Sub PB 53-54 Lots 1-B & 2-B
d. Owner's Name: HMT Country Club Villas c/o David Hall
e. Owner's Mailing Address: 2135 Arch Creek Dr., Miami, FL 33181
f. Building Official Folio Number: 11-2232-027-0120 (Bldg.1)
g. Building Code Occupancy Classification: R2
h. Present Use: Multifamily Residential
i. General Description, Type of Construction, Size, Number of Stories, Special Features: 2-Story
CBS & Reinforced Concrete Structure. Approximately 9,817 S.F.
j. Additions to original structure: None noted (no plans available on site).
-6-
8203 SW 1241h Slrccl, Miami, Florida 33156 * 71,1: (3,J3; ' 4-7377 * Fa_:: (303) 234-7664
1280 NE 105th Street
Allied Building Inspection Services
Inspections .Testing. Engineering
Guidelines and Information for Re -Certification of
Electrical Systems of Forty (40) Year Structures
1. Electric Service
West
1. Size: Amperage ( 400 ) Fuses (X) Breakers ( X )
2. Phase: Three Phase ( ) Single Phase ( X )
3. Condition: Good (X) Fair ( ) Needs Repair ( )
4. Comments: 1 weatherhead, 10 meters, 1 main disconnect, 10 panels
East
1. Size: Amperage ( 400 ) Fuses (X) Breakers ( X )
2. Phase: Three Phase ( ) Single Phase ( X )
3. Condition: Good (X) Fair ( ) Needs Repair ( )
4. Comments: 1 weatherhead, 8 meters, 1 main disconnect, 8 panels
2. Meter and Electric Room
1. Clearances: Good ( X ) Fair ( ) Requires Correction ( )
2. Comments: All equipment is satisfactory.
3. Gutters
1. Location: Good ( X) Repairs Required ( )
2. Taps & Fill: Good ( X) Repairs Required ( )
3. Comments: Satisfactory.
4. Electrical Panels
1. East 1-7:
60 Amps ea, indoor
2. House East:
60 Amps, indoor
3. West 8-16:
60 Amps ea, indoor
4. House West:
100 Amps, indoor
5. Comments:
Satisfactory.
Good ( X) Repairs Required
Gocd ( X F epairs Require(, J p • ��ra�d
Goud (X Repai; s Requi `
r
Good ( X) Repairs Requir . �
AR0017521
7
8203 SVV 1241h Slreel, Miami, Florida 33156 ' Ti--.'.- (3C5) 231-7_'77 Fay- (305) 234-7664
1
1280 NE 105th Street
ALUED
INSPECTION SF. RViCE.S
5. Branch Circuits
1. Identified: Yes ( X )
2. Conductors: Good ( X )
3. Comments: Satisfactory.
6. Grounding of Service
. Condition: Good ( X )
• Comments: Satisfactory.
7. Grounding of Equipment
• Condition: Good ( X )
Comments: Satisfactory.
8. Service Conduits/Raceways
• Condition: Good ( X )
• Comments: Satisfactory.
9. Service Conductors and Cables
■ Condition: Good ( X )
• Comments: Satisfactory.
10. Types of Wiring Methods
■ Condition:
a. Conduit Raceways:
b. Conduit PVC:
c. NM Cable:
d. BX Cable:
11. Feeder Conductors
Allied Building Inspection Services
Inspections .Testing. Engineering
Must Be Identified ( )
Deteriorated ( ) Must Be Replaced ( )
Repairs Required ( )
Repairs Required ( )
Repairs Required ( )
Repairs Required ( )
Good ( X) Repairs Required ( )
Good ( X) Repairs Required ( }
Good ( ) Repairs Required ( )
Good ( X) Repairs Required ( )
■ Condition:
Good ( X )
• Comments:
Satisfactory.
12. Emergency Lighting
• Condition:
Good ( X )
■ Comments:
Satisfactoryj.
R,3p3irs Required ( )
Repairs Required ( )
c., . ;�a,vacd Reara01,.
_8-
8203 SW 124th Sireei, Miami, Flo.•ida �3150 * T-4: (305) 234-7377 * Fax: (305) 234-7664
�� �: ( -1A- ) , j '
)) f�6i� -,
AE Dr,INSPEcnONSEKV!CES
1280 NE 105th Street
Allied Building Inspection Services
Inspections .Testing. Engineering
13.
Building Egress Illumination
• Condition: Good ( X)
Repairs Required ( )
• Comments: Satisfactory.
14.
Fire Alarm System
• Condition: Good ( )
Repairs Required ( )
• Comments: N/A
15.
Smoke Detectors
• Condition: Good ( X )
Repairs Required ( )
• Comments: Satisfactory.
16.
Exit Lights
• Condition: Good ( X )
Repairs Required ( )
• Comments: Satisfactory.
17.
Emergency Generator
• Condition : Good ( )
Repairs Required ( )
• Comments: N/A.
18.
Wiring in Open or Undercover Parking Garage Areas
Condition: Good ( X)
Repairs Required ( )
■ Comments: Satisfactory.
19.
Open or Undercover Parking Surface and Security Lighting
• Condition: Good ( X)
Requires Additional Illumination (
}
• Comments: Satisfactory.
20.
Swimming Pool Wiring
jpF Ff--Op
• Condition: Good ( )
Repairs Required ( )
��' �rd Rearo,,
• Comments: N/A.
21.
Wiring of Mechanical Equipment
' '�" V
• Condition: Good (A )
Repci;s Required ( )
•
• Comments: Satisfactory.-
9 � J
8203 SPV 1241h Street, Miami, Florida Tel: (305) 234-7377 * Fax: (305) 234-7664 � J
1280 NE 105th Street
ALUED
B�GINSPECTION Sf_sa11" S.
22. General Additional Comments
• Comments: Satisfactory
Allied Building Inspection Services
Inspections .Testing. Engineering
. • �a.14 Reardon',
,o
PRo0��521 •f•cam
ti� ' f, itiI
-10- f�
8203 SW 1241h Slreel, Miami, Florida .;3; fC * T21: (305) 234-7377 * Fax: (305) 234-7664 ,,n �
1280 NE 105th Street
Allied Building inspection Services
9ma
Inspections .Testing. Engineering
Certification of Compliance with Parking Lot Guardrails Requirements
in Chapter 8C of the Code of Miami -Dade County
Date: November 30, 2015
Re: Case Number: Folio: 11-2232-027-0120
Property Address: 1280 NE 105th Street, Miami Shores, FL 33138
Approximately 9,817 S.F.
Building Description: Multifamily Residential —16 Units
The undersigned states the following:
I am a Florida registered professional engineer or architect with an active license.
On 11/24/15, 1 inspected the parking lot(s) servicing the above referenced building for
compliance with Section 8C-6 and determined the following:
( X ) The parking lot(s) is not adjacent to or abutting a canal, lake or other body of
water.
( ) The parking lot(s) is adjacent to or abutting a canal, lake or other body of water
and parked vehicles are protected by a guardrail that complies with Section 8C-6
of the Miami -Dade County Code.
The parking lot(s) is adjacent to or abutting a canal, lake or other body of water
and parked vehicles are not protected by a guardrail that complies with Section
8C-6 of the Miami -Dade County Code. I have advised the property owner that
he/she must obtain a permit for the installation of the guardrail and obtain all
required inspection approvals no latarthan April 10, 2014. O
� e ';'E(� Re�rd01)
}It -
II �� ; k �
Mark Reardon, RA 0017621
8203 SYV 1241h Slreel, Miami, 33155 Tcl: (_'05) : 31-awf3:3-1-76G4
1280 NE 1O5th Street
_;+"ram- 4A
rtlM0m-r- .
Allied Building Ins ection Services
Inspections .Testing. Engineering
8203 SIV 1241h Slh•eel, Miami, Flwlela 33:. ( * Tel: ; 305) 23 /-7377 * Fax: (303) 23 J-7664
1280 NE 105th Street
A.EDENGINSPECTIONSEHVI"CES
hm.
_ 73-
Allied Building Inspection Services
Inspections .Testing. Engineering
4-
8203 SW 12-llh Sireel, Miami, Florida 3'156 * Te (305) 234-/377 >,_ Fax: (305) 234-7661
c
o n of
co
3
c
i p (D NJ
{G
7
�p n
n 3
O fD
Ln
(�
m
o
MIAMI SHORES
COUNTRY CLUB VILLAS
c °o � �vz v
3 G p fD N o N {C
cn o n
z2 Ln =�
n
o rm
v
MIAMI SHO
COUNTRY CLUB
C
N .-
cL
P
WESTGATE
THE FUTURE IS HERE ... AND IT'S QUITE BRIGHT.
TH UNDERJSERI E 5
Available with optional
yoke with 1/2" hub
adapter for mounting to
weatherproof boxes
y LF series are
prewiced withth 1838" cord
LF. (1813 51TW) and
compression fitting
LF-30CW
LF-30WW
LF-30RGB
LED Flood Lights
Ideal for general site lighting, alleys, loading docks, doorways,
pathway and parking areas. Replace existing HID flood lights.
Great for use with motion sensors or other instant on/off controls.
ELECTRICAL SPECIFICATIONS:
• Voltage:100-277VAC 50/60Hz
• Input current: 0.3A
• Wattage: 30W
■ Other wattages available:
1OW, 20W, 50W, 80W, 10OW, 150W
Power factor: >0.95
. Driver voltage: 8-24VDC
• Output current: 1250mA
• Driver efficiency: 86%
LIGHTING SPECIFICATIONS:
• LED type/brand: Epistar COB
• LED chips quantity:lpc
. Total lumens: CW 2700/ WW 2650/ RGB 2400
• Color temperature: CW 5000K/ WW 350OK/ RGB
■ Color rendering index: >68
• Beam angle: 120`
JOB NAME:
DATE:
TYPE:
L D
r o
H
o 0
8-3/4"(L) x 7-1/2"(H) x 5"(D)
MODEL
WATTS
VOLTAGE
LUMENS
COLOR TEMP
LF-30CW
30W
120/277V AC
2700
5000K
LF-30WW
30W
120/277V AC
2650
3500K
LF-30-RGB
L30W
120/277V AC
2400
RGB
HOUSING SPECIFICATIONS:
. Die-cast aluminum with powder coat with finishing color
of dark bronze
Door frame made of die-cast aluminum with four stainless
steel retention screws
e Lens: Tempered glass with seamless silicone gasket
Wet Locations: Suitable for wet locations, IP65
MOUNTING:
• Fully adjustable trunnion with option 1/2" hub
mounting option
WhRRANTY: 7 years
• Upekatin� tecnpera:ure: -30°C + 40°C
• Storage temperature: Humidity -40°C to +80'C, 10 to 90% RH
CER`i IFICATIONG. u,,, Cul
CL
C"'T
�r
Q •
WESTGATE MFG., INC. 2041 Davie Avenue, Commerce, CA 90040 0 Phone (877) 805-2252 • Fax (877) 809-2252
WESTGATE
THE FUTURE IS HERE ... AND IT'S QUITE BRIGHT!
THUNDE FRIES
LF-3BCW
LF-30WW
LF-3BRGB
MODEL
WATTS
VOLTAGE
LUMENS
COLOR TEMP
LF-30CW
30W
120/277V AC
2700
5000K
LF-30WW
30W
120/277V AC
2650
3500K
LF-30-RGB
30W
120/277V AC
2400
RGB
PHOTOMETRIC&
Test for LF-30CW
Spectral Power Distribution
JOB NAME:
DATE:
TYPE:
CI
LISTED ����� @8#*6TAR
J
Illuminance Plots
Ilex oet11950 in
ft
5 903E-002 3.2e11
L
5.247E-002
4.591E-002
3.935E-00Z 6.562ft
3.279E-002
LL
2.623E-002
1.96BE•002
-002 9.e43ft
1.312E
3■
6.550E-0ai I
0.000E+000
350 400 450 500 550 600 650 700 750 B00 B50 900 950 1000 105C 13.12ft
W&eleno 6.
16. 6ft
5.
salght ■ev9, ds9 Angle:106.99deg Diameter
Note:The Curves indieaea the illWnetad Brea and the overage
illumination when the lumlnaire is at different distance.
Luminous Intensity Distribution Plots
-/+180
-150 150
-120 j`jr 120
C V OM:ad
—CO/100,107.8°
-30 30 — C30/210,108.5-
—C60/260,110.6'
0 /270 112 3°
AVBRAG/ REAM ANGLE(506):109.5 dw '
o ,o
WESTGATE MFG., INC. 2041 Davie Avenue, Commerce, CA 90040 9 Phone (877) 805-2252 a Fax (877) 809-2252 o .'
Certification of Compliance with Parking Lot Illumination
Standards in Chapter 80-3 of the Code of Miami -Dade County
Date: November 30, 2015
Re: Case Number: Folio: 11-2232-027-0120
Property Address: 1280 NE 105th St, Miami Shores FL 33138 — 9817 SF +/-
Building Description: Multifamily Residential —16 Units
The undersigned states the following:
1. 1 am a Florida registered professional engineer or architect with an active license.
1. On the evening of November 6, 2015, we measured the level of illumination in the
parking lot(s) serving the above referenced building.
2. Maximum 9.0 foot candle per SF, Minimum 1.0 foot candle per SF;
Minimum to Maximum ratio 1 : 9.0 , foot candle 1.4 average per SF.
3. The level of illumination provided in the parking lot(s) meets the minimum standards
for the occupancy classification of the building as established in Section 8C-3 of
the Code of Miami -Dade County.
4,e)j, (License)
1-
FEB 0 5 r U 16
I
1280 NE 105th St
Allied Building Inspection Services
Inspections. Testing. Engineering
Certification of Compliance with Parking Lot Illumination
Standards in Chapter 8C-3 of the Code of Miami -Dade County
Date: January 22, 2016
Re: Case Number: Folio: 11-2232-027-0120
Property Address: 1280 NE 105th St, Miami Shores FL 33138 — 9817 SF +/-
Building Description: Multifamily Residential —16 Units
The undersigned states the following,
1. 1 am a Florida registered professional engineer or architect with an active license.
2. On the evening of January 21, 2016, we measured the level of illumination in the
parking lot(s) serving the above referenced building.
3. Maximum 3.1 foot candle per SF, Minimum 1.3 foot candle per SF;
Minimum to Maximum ratio 1 : 2.4 , foot candle 2.0 average per SF.
4. The level of illumination provided in the parking lot(s) meets the minimum standards
for the occupancy classification of the building as established in Section 8C-3 of
the Code of Miami -Dade County. lt;_
LE
Mark Reardon, RA 0017521
t 6,s3rd Reara'%%
��€-E-o_
-I-
8203 SW 12-11h Slreel, Miami, Florida 33156 * Tel: (305) 234-7377 * Fax: (303) 234-7664