Loading...
RCRT-7-15-1948Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address 1280 NE 105 Street Miami Shores, FL 33138- Owner Information COUNTRY CLUB VILLAS OF MIAMI Permit No. RCRT-7-15-1948 Permit Type: 40 Yr ReCertification Permit Work Classification: ReCertification Permit Status: APPROVED Issue Date: 5/10/2018 1 Expiration: 1 ° 06/2018 Parcel Number 1122320270120 Block: Lot: Address 1280 NE 105 Street MIAMI SHORES FL 33138- 2135 ARCH CREEK Drive MIAMI FL 33181- Contractor(s) Phone Cell Phone HOME OWNER Fees Due Amount 40 Yr Recertification Fee $250 00 40 Yr ReCertification Fee $900 00 Miscellaneous Fee $80 00 Total: $1,230.00 Applicant COUNTRY CLUB VILLAS OF MIS Phone Cell (305)219-3762 Valuation: $ 0.00 Total Sq Feet: 0 Pay Date Pay Type Amt Paid Amt Due Invoice # RCRT-12-15-58086 05/10/2018 Credit Card $ 980.00 $ 0.00 Invoice # RCRT-7-15-56568 12/11/2015 Check #: 4226998� $ 250.00 $ 0.00 HvauaDie inspections: Inspection Type: Final PE Certification 40 notification sent PE Certification Letter Review Electrical Review Electrical Review Electrical Review Electrical Review Building Review Building Review Structural In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zonln ermore, I authorize the above -named contractor to do the work stated. ce)t2 7c�� May 10, 2018 Authorized Signature: Owner / Applicant / Contractor / Agent Dare Building Department Copy May 10, 2018 1 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 C Master Permit No.y C (ZT 1 1 J— I g Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: !� ► " L S S A- Folio/Parcels?►: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder):�ne Address: City: Tenant/Lessee Name: Email: r, eev LLB CONTRACTOR: Company Name: Address: City: Qualifier Name: State Certification or Registration #: DESIGNER: Architect/Engineer: Address: Value of Work for this Permit: $ Type of Work: ❑ Addition Description of Work: ❑ Alteration Specify color of color thru tile: Submittal Fee $ Scanning Fee $ Technology Fee $` Structural Reviews $ (Revised02/24/2014) State: Zip: �7 ( Phone#: l [, o hone#: Phone#: Certificate of Competency #: Phone#: City: State: Zip: Square/Linear Footage of Work: ❑ New ❑ Repair/Replace ❑ Demolition a Permit Fee $ _ CCF $_ Radon Fee $ DBPR $ Training/Education Fee $ CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ �� OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-2232-027-0120 1280 NE 105 ST Miami Shores, FL 33138-2146 MIAMI SHORES VILLAS LLC Property Address: Owner Mailing Address PA Primary Zone 724 NE 79 ST MIAMI, FL 33138 USA 3000 MULTI -FAMILY - GENERAL 0303 MULTIFAMILY 10 UNITS PLUS MULTIFAMILY 3 OR MORE UNITS Primary Land Use Beds / Baths / Half 16 / 16 / 0 Floors 2 Living Units 16 Actual Area Sq.Ft Living Area Sq.Ft 9,817 Sq.Ft Adjusted Area Lot Size 27,200 Sq.Ft 1955 Year Built Assessment Information Year 2017 2016 2015 Land Value $537,200 $537,200 $537,200 Building Value $622,800 $612,800 $532,800 XF Value $0 $0 $0 Market Value $1,160,000 $1,150,000 $1,070,000 Assessed Value $1,160,000 $1,150,000 $1,065,557 Benefits Information Benefit Type 2017 2016 2015 Non -Homestead Cap Assessment Reduction $4,443 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). IShort Legal Description I ANCO SUB PB 53-54 LOTS 1-B & 2-B LOT SIZE 27200 SQUARE FEET OR 15856-2309 0393 1 COC 22315-3981 02 2004 6 Generated On : 5/3/2018 Taxable Value Information 20171 2016� 2015 County Exemption Value $0 $0 $0 Taxable Value 1 $1,160,000 $1,150,000 $1,065,557 School Board Exemption Value $0 $0 $0 Taxable Value $1,160,000 $1,150,000 $1.070,000 City Exemption Value $0 $0 $0 Taxable Value 1 $1,160,000 $1,150,000 $1,065,557 Regional Exemption Value $0 $0 $0 Taxable Value $1,160,000 $1,150,000 $1,065,557 Sales Information Previous Sale Price OR Book -Page Qualification Description 01/24/2018 $1,850,000 30847-1498 Qual by exam of deed 09/19/2011 $1,100,000 27833-1191 Qual by exam of deed 02/01/2004 $343,000 22315-3981 Other disqualified 03/01/1993 $445,000 15856-2309 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamid ade.gov/info/disclaimer.asp Version: Dori:;:c:r: ,... C,: �ir•;:r;;:-•au:; 1r� Sorg �r/'M J �'.'is �r_f ��?s oaF�a� 1�af .��cti'. F�f �1=rrr�?c� ;,,,•f,•�,t.� DetwMerk of State / Division of Cornnrations / $eBrGh RecafK-k / De!_sll BkQncun�enl Numb,- / Detail by Entity Name Florida Limited Liability Company MIAMI SHORES VILLAS, LLC Filing Information Document Number L18000009411 FEI/EIN Number NONE Date Filed 01/10/2018 State FL Status ACTIVE Principal Address 724 N.E. 79 STREET MIAMI, FL 33138 Mailing Address 724 N.E. 79 STREET MIAMI, FL 33138 Registered Ag€nt Natme_& Address REITER, CORY 724 N.E. 79 STREET MIAMI, FL 33138 Authorized Persons Detail Name & Address Title MGR REITER, CORY 724 N.E. 79 STREET MIAMI, FL 33138 Annual Reports No Annual Reports Filed 11110( 1 Florida United iability Vicw image in PDF tonnat http://search.sunbiz.org/Inquiry/CorporationSearchISearchResultDetail?inqui rytype=EntityName&directionType=lnitial&searchNameOrder=M IAM ISHORESVI.. 1/2 1280 NE 105th Street A.IEDF„ INSPE November 30, 2015 Building Official City of Miami Shores 10050 NE 2 Avenue Miami Shores Village FL 33138 Allied Building Ins ection Services Inspections . Testing. Engineering RE: 40-Year Building Re -Certification Inspection Reports SUBJ: 1280 NE 105th Street, Miami Shores, FL 33138 r ;, WI � � T , Folio: 11-2232-027-0120 —Bldg. 1 Dear Building Official, Enclosed, ase find the structural and electrical reports iL office. The building is structurally safe for its intended us� compliance with section 8-11(F) of the Miami Dade Coun-t building is also electrically safe for its use and present occup Code & Miami Dade County Chapter 8C-3. (Parking illumily attached hereto.) Please allow this letter to serve as out i MIAMI SHORES VILLAGE APPROVED BY DATE he_fDma�dIlag fired bar J 3,% es Itative nt occupancy, inAdminisCode h IRT&F r Florid 'ding j Lion is ce iffed bt others. ! noted subject property. As a routine matter, in order to avoid possible misunders�aM"1,Nl should be construed directly or indirectly as a guarantee for any poi To the best of my knowledge and ability, this report repre'��H+i . 9 the present condition of the building. P,LDG. Sincerely, r OF FQ) Allied Building Inspection Services, Inc. ,.ice ;d.!�rE e ' AR0017521 AA y Mark Reardon, RA 0017521 11A g in this appraisal of 3 COMPL;ANC:E WITH ALL FEDERAL � OUN1Y RULES AND REGULATIONS 8203 SW 1241h Sfreel. Miami, Florida 33156 * Tel: (305; 23=4-7 377 * Fa:.: (305) 234-7664 990 1280 NE 105th Street Allied Buildin Iris ection Services Inspections .Testing. Engineering Minimum Inspection Procedural Guidelines for Building Structural Re -Certification 1. Description of Structure a. Name of Title: HMT Country Club Villas b. Street Address: 1280 NE 105th Street, Miami Shores, FL 33138 c. Legal Description: Anco Sub PB 53-54 Lots 1-B & 2-B d. Owner's Name: HMT Country Club Villas c/o David Hall e. Owner's Mailing Address: 2135 Arch Creek Dr., Miami, FL 33181 f. Building Official Folio Number: 11-2232-027-0120 (Bldg. 1) g. Building Code Occupancy Classification: R2 h. Present Use: Multifamily Residential i. General Description, Type of Construction, Size, Number of Stories, Special Features: 2-Story CBS & Reinforced Concrete Structure. Approximately 9,817 S.F. j. Additions to original structure: None noted (no plans available on site). 2. Present Condition of Structure of F� oR�Oq a. General alignment (note good, fair, poor, explain if significant) S ra Rearao 1. Bulging: Good y,, ez ,,,1 2. Settlement: Good 3. Defections: Good 4. Expansion: Good 5. Contraction: Good b. Portions showing distress (note beams, columns, structural walls, floors, roofs, othe Noted. c. Surface conditions - describe general conditions of finishes, noting cracking, spalling, peeling, signs of moisture penetration & stains: No spalling or significant cracks noted. No moisture penetration noted. d. Cracks - note location in significant members. Identify crack size as "Hairline" if barely discernible; "Fine" if less than 1 mm in width; "Medium" if between 1 - 2 mm in width; "Wide" if over 2 mm: Hairline and fine cracks in CBS walls, not significant. e. General extent of deterioration - cracking or spLI:ing of corcre`_e or masonry; oxidation of metals; rot or borer attack in wood: No spalling or signiffcant tucks natid. f. Previous patching or repairs: Some minor stucco anu plaster patches noted, satisfactory. g. Nature of present loading - indicate residential, commercial, other estimate magnitude: - 7 - 8203 SW 1241h Street, Miami, Florida 3315t, * Tel • (305) 234-7377 * Far: (303) 234-7664 1280 NE 105th Street A_llied_Buildin_g Inspection Services Inspections. Testing. Engineering 3. Inspections a. Date of notice of required inspection: Unknown b. Date(s) of actual inspection: 11/24/15 c. Name and qualification of individual submitting inspection report: Mark Reardon, RA 0017521 d. Description of any laboratory or other formal testing, if required, rather than manual or visual procedures: Only manual hammer sounding of concrete. e. Structural Repair (note appropriate line): 1. None required: None Required. 2. Required (describe and indicate acceptance): None Required. 4. Supporting Data a. sheets written data 0 b. photographs (see attached) c. drawings or sketches 0 5. Masonry Bearing Walls (indicate good, fair or poor) a. Concrete masonry units: Good b. Clay tile or terra cotta units: NIA c. Reinforced concrete tie columns: Good d. Reinforced concrete tie beams: Good e. Lintels: NIA f. Other type bond beams: NIA g. Masonry finishes - exterior: 1. Stucco: Good 2. Veneer: Good 3. Paint only: NIA 4. Other (describe): NIA h. Masonry finishes — interior: 1. Vapor barrier: NIA 2. Furring and plaster: Good 3. Paneling: NIA 4. Paint only: NIA 5. Other (describe): Good, Gypsum Board -3- 8203 SIF 12-11h Shreel. Miami, Florida 33156 * Tel: (3,)5; 23-l-377 * Fax: (305) 23-1-766-4 1280 NE 105th Street A 1 ED INSPECTIONSEE2'0CES Allied Building Inspection Services Inspections . Testing. Engineering i. Cracks: 1. Location (note beams, columns, other): CBS Walls. 2. Description: Hairline and fine cracks, not significant j. Spalling: 1. Location (note beams, columns, other): None Noted. 2. Description: N/A k. Rebar corrosion (check appropriate line): 1. None visible: None Visible. 2. Minor -patching will suffice: N/A 3. Significant -but patching will suffice: N/A 4. Significant -structural repairs required (describe): N/A I. Samples chipped out for examination in spalled areas: 1. No: N/A 2. Yes (describe color texture, aggregate, general quality): NIA 6. Floor and Roof Systems ���+Cr, Ltd Rpara < , 41 po s a. Roof: 11 1 1. Describe (flat, slope, type roofing, type roof deck, condition):2:12 sloped roof w/ clay tiles over wood deck; in good condition. 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment & condition of supports: None 3. Note types of drains & scuppers: None. b. Floor system(s): 1. Describe (type of system framing, material, spans, condition): Concrete floor slabs on - grade and above grade; in good condition. c. Inspection - note exposed areas available for inspection, and where it was found necessary to open ceilings, etc. for inspection of typical framing members: Limited view of framing through scuttle. 7. Steel Framing Systems a. Description: Columns at exterior walkways b. Exposed steel: describe condition of paint & degree of ^orrosion: Palpt is good; corrosion is insignificant. c. Concrete or other fireproofing - note any cracking or spallir,g, i iota where any covering was removed for inspection: NIA. d. Elevator sheave beams & connections, anJ machine `loor oeams (note condition): NIA -4- S203 SW 124lh Slreel, Miami, Florida 33156 * 7 !: (305) 221-7377 * Fcr_•:: (305) 234-7664 1280 NE 105th Street Allied Building Inspection Services Inspections .Testing. Engineering 8. Concrete Framing Systems a. Full description of structural system: Continuous pad footings, slab -on -grade, tie -columns, tie -beams, stairs. b. Cracking: 1. Not significant: Not significant. 2. Location & description of members affected & type cracking: Fine & hairline, CBS walls only c. General condition: Good Condition. d. Rebar corrosion (check appropriate line): 1. None visible: None Visible. 2. Location/description of members affected & type cracking: NIA 3. Significant but patching will suffice: NIA 4. Significant - structural repairs required (describe): NIA e. Samples chipped out in spalled areas: 1. No: N/A 2. Yes (describe color, texture, aggregate, & general quality): N/A 9. Windows a. Type (wood, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted, fixed, other): Metal jalousie, awning. b. Anchorage - type & condition of fasteners and latches: Screws; Fair. c. Sealants -type & condition of perimeter sealants & at mullions: Caulking; Fair. d. Interior seals -type & condition at operable vents: Vinyl strips; Fair. e. General condition: Fair. 10. Wood Framing a. Type - fully describe if mill construction, light construction, major spans, trusses: Roof is of conventional framing — 2x rafters/joists, 16" O.C. -12' to 14' spans, in fair condition; Walls are load -bearing and non -load -bearing partitions — 2x studs, 16" O.C. b. Note metal fittings (i.e. angles, plates, bolts, split pintles, pintles, other) and note condition: _ None. �DFF �; c. Joints - note if well fitted and still closed: Good &�- ' " ` d. Drainage -note accumulations of moisture: None J�' � Edward Re,,,,ao . e. Ventilation - note any concealed spaces not ventilated: Good f. Note any concealed spaces opened for inspection: Nude AR0017521 al i \''LL77 VV-' YiJ f_J N203 SW 1 41h Slreel. Miami. Florida 33156 * 7-,/: (305; '_'4-7377 * Frr_:: (305) 234-7664 � 1280 NE 105th Street Allied Buildinq Inspection Services Inspections . Testing. Engineering Minimum Inspection Procedural Guidelines for Building Electrical Re -Certification Inspection Commenced Inspection Made By: Date: November 24, 2015 Signature: AF�Lopq,� Print Name: Mark Reardon �• ` �,�acd Reardo•, Inspection Completed Date: November 30, 2015 Title: RA 0017521 'P�pp1�5�1 v Address: 8203 SW 124 Street'. Miami, Florida 33158 _ s � �gG 1. Description of Structure a. Name of Title: HMT Country Club Villas b. Street Address: 1280 NE 105th Street, Miami Shores, FL 33138 c. Legal Description: Anco Sub PB 53-54 Lots 1-B & 2-B d. Owner's Name: HMT Country Club Villas c/o David Hall e. Owner's Mailing Address: 2135 Arch Creek Dr., Miami, FL 33181 f. Building Official Folio Number: 11-2232-027-0120 (Bldg.1) g. Building Code Occupancy Classification: R2 h. Present Use: Multifamily Residential i. General Description, Type of Construction, Size, Number of Stories, Special Features: 2-Story CBS & Reinforced Concrete Structure. Approximately 9,817 S.F. j. Additions to original structure: None noted (no plans available on site). -6- 8203 SW 1241h Slrccl, Miami, Florida 33156 * 71,1: (3,J3; ' 4-7377 * Fa_:: (303) 234-7664 1280 NE 105th Street Allied Building Inspection Services Inspections .Testing. Engineering Guidelines and Information for Re -Certification of Electrical Systems of Forty (40) Year Structures 1. Electric Service West 1. Size: Amperage ( 400 ) Fuses (X) Breakers ( X ) 2. Phase: Three Phase ( ) Single Phase ( X ) 3. Condition: Good (X) Fair ( ) Needs Repair ( ) 4. Comments: 1 weatherhead, 10 meters, 1 main disconnect, 10 panels East 1. Size: Amperage ( 400 ) Fuses (X) Breakers ( X ) 2. Phase: Three Phase ( ) Single Phase ( X ) 3. Condition: Good (X) Fair ( ) Needs Repair ( ) 4. Comments: 1 weatherhead, 8 meters, 1 main disconnect, 8 panels 2. Meter and Electric Room 1. Clearances: Good ( X ) Fair ( ) Requires Correction ( ) 2. Comments: All equipment is satisfactory. 3. Gutters 1. Location: Good ( X) Repairs Required ( ) 2. Taps & Fill: Good ( X) Repairs Required ( ) 3. Comments: Satisfactory. 4. Electrical Panels 1. East 1-7: 60 Amps ea, indoor 2. House East: 60 Amps, indoor 3. West 8-16: 60 Amps ea, indoor 4. House West: 100 Amps, indoor 5. Comments: Satisfactory. Good ( X) Repairs Required Gocd ( X F epairs Require(, J p • ��ra�d Goud (X Repai; s Requi ` r Good ( X) Repairs Requir . � AR0017521 7 8203 SVV 1241h Slreel, Miami, Florida 33156 ' Ti--.'.- (3C5) 231-7_'77 Fay- (305) 234-7664 1 1280 NE 105th Street ALUED INSPECTION SF. RViCE.S 5. Branch Circuits 1. Identified: Yes ( X ) 2. Conductors: Good ( X ) 3. Comments: Satisfactory. 6. Grounding of Service . Condition: Good ( X ) • Comments: Satisfactory. 7. Grounding of Equipment • Condition: Good ( X ) Comments: Satisfactory. 8. Service Conduits/Raceways • Condition: Good ( X ) • Comments: Satisfactory. 9. Service Conductors and Cables ■ Condition: Good ( X ) • Comments: Satisfactory. 10. Types of Wiring Methods ■ Condition: a. Conduit Raceways: b. Conduit PVC: c. NM Cable: d. BX Cable: 11. Feeder Conductors Allied Building Inspection Services Inspections .Testing. Engineering Must Be Identified ( ) Deteriorated ( ) Must Be Replaced ( ) Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) Good ( X) Repairs Required ( ) Good ( X) Repairs Required ( } Good ( ) Repairs Required ( ) Good ( X) Repairs Required ( ) ■ Condition: Good ( X ) • Comments: Satisfactory. 12. Emergency Lighting • Condition: Good ( X ) ■ Comments: Satisfactoryj. R,3p3irs Required ( ) Repairs Required ( ) c., . ;�a,vacd Reara01,. _8- 8203 SW 124th Sireei, Miami, Flo.•ida �3150 * T-4: (305) 234-7377 * Fax: (305) 234-7664 �� �: ( -1A- ) , j ' )) f�6i� -, AE Dr,INSPEcnONSEKV!CES 1280 NE 105th Street Allied Building Inspection Services Inspections .Testing. Engineering 13. Building Egress Illumination • Condition: Good ( X) Repairs Required ( ) • Comments: Satisfactory. 14. Fire Alarm System • Condition: Good ( ) Repairs Required ( ) • Comments: N/A 15. Smoke Detectors • Condition: Good ( X ) Repairs Required ( ) • Comments: Satisfactory. 16. Exit Lights • Condition: Good ( X ) Repairs Required ( ) • Comments: Satisfactory. 17. Emergency Generator • Condition : Good ( ) Repairs Required ( ) • Comments: N/A. 18. Wiring in Open or Undercover Parking Garage Areas Condition: Good ( X) Repairs Required ( ) ■ Comments: Satisfactory. 19. Open or Undercover Parking Surface and Security Lighting • Condition: Good ( X) Requires Additional Illumination ( } • Comments: Satisfactory. 20. Swimming Pool Wiring jpF Ff--Op • Condition: Good ( ) Repairs Required ( ) ��' �rd Rearo,, • Comments: N/A. 21. Wiring of Mechanical Equipment ' '�" V • Condition: Good (A ) Repci;s Required ( ) • • Comments: Satisfactory.- 9 � J 8203 SPV 1241h Street, Miami, Florida Tel: (305) 234-7377 * Fax: (305) 234-7664 � J 1280 NE 105th Street ALUED B�GINSPECTION Sf_sa11" S. 22. General Additional Comments • Comments: Satisfactory Allied Building Inspection Services Inspections .Testing. Engineering . • �a.14 Reardon', ,o PRo0��521 •f•cam ti� ' f, itiI -10- f� 8203 SW 1241h Slreel, Miami, Florida .;3; fC * T21: (305) 234-7377 * Fax: (305) 234-7664 ,,n � 1280 NE 105th Street Allied Building inspection Services 9ma Inspections .Testing. Engineering Certification of Compliance with Parking Lot Guardrails Requirements in Chapter 8C of the Code of Miami -Dade County Date: November 30, 2015 Re: Case Number: Folio: 11-2232-027-0120 Property Address: 1280 NE 105th Street, Miami Shores, FL 33138 Approximately 9,817 S.F. Building Description: Multifamily Residential —16 Units The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. On 11/24/15, 1 inspected the parking lot(s) servicing the above referenced building for compliance with Section 8C-6 and determined the following: ( X ) The parking lot(s) is not adjacent to or abutting a canal, lake or other body of water. ( ) The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are not protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. I have advised the property owner that he/she must obtain a permit for the installation of the guardrail and obtain all required inspection approvals no latarthan April 10, 2014. O � e ';'E(� Re�rd01) }It - II �� ; k � Mark Reardon, RA 0017621 8203 SYV 1241h Slreel, Miami, 33155 Tcl: (_'05) : 31-awf3:3-1-76G4 1280 NE 1O5th Street _;+"ram- 4A rtlM0m-r- . Allied Building Ins ection Services Inspections .Testing. Engineering 8203 SIV 1241h Slh•eel, Miami, Flwlela 33:. ( * Tel: ; 305) 23 /-7377 * Fax: (303) 23 J-7664 1280 NE 105th Street A.EDENGINSPECTIONSEHVI"CES hm. _ 73- Allied Building Inspection Services Inspections .Testing. Engineering 4- 8203 SW 12-llh Sireel, Miami, Florida 3'156 * Te (305) 234-/377 >,_ Fax: (305) 234-7661 c o n of co 3 c i p (D NJ {G 7 �p n n 3 O fD Ln (� m o MIAMI SHORES COUNTRY CLUB VILLAS c °o � �vz v 3 G p fD N o N {C cn o n z2 Ln =� n o rm v MIAMI SHO COUNTRY CLUB C N .- cL P WESTGATE THE FUTURE IS HERE ... AND IT'S QUITE BRIGHT. TH UNDERJSERI E 5 Available with optional yoke with 1/2" hub adapter for mounting to weatherproof boxes y LF series are prewiced withth 1838" cord LF. (1813 51TW) and compression fitting LF-30CW LF-30WW LF-30RGB LED Flood Lights Ideal for general site lighting, alleys, loading docks, doorways, pathway and parking areas. Replace existing HID flood lights. Great for use with motion sensors or other instant on/off controls. ELECTRICAL SPECIFICATIONS: • Voltage:100-277VAC 50/60Hz • Input current: 0.3A • Wattage: 30W ■ Other wattages available: 1OW, 20W, 50W, 80W, 10OW, 150W Power factor: >0.95 . Driver voltage: 8-24VDC • Output current: 1250mA • Driver efficiency: 86% LIGHTING SPECIFICATIONS: • LED type/brand: Epistar COB • LED chips quantity:lpc . Total lumens: CW 2700/ WW 2650/ RGB 2400 • Color temperature: CW 5000K/ WW 350OK/ RGB ■ Color rendering index: >68 • Beam angle: 120` JOB NAME: DATE: TYPE: L D r o H o 0 8-3/4"(L) x 7-1/2"(H) x 5"(D) MODEL WATTS VOLTAGE LUMENS COLOR TEMP LF-30CW 30W 120/277V AC 2700 5000K LF-30WW 30W 120/277V AC 2650 3500K LF-30-RGB L30W 120/277V AC 2400 RGB HOUSING SPECIFICATIONS: . Die-cast aluminum with powder coat with finishing color of dark bronze Door frame made of die-cast aluminum with four stainless steel retention screws e Lens: Tempered glass with seamless silicone gasket Wet Locations: Suitable for wet locations, IP65 MOUNTING: • Fully adjustable trunnion with option 1/2" hub mounting option WhRRANTY: 7 years • Upekatin� tecnpera:ure: -30°C + 40°C • Storage temperature: Humidity -40°C to +80'C, 10 to 90% RH CER`i IFICATIONG. u,,, Cul CL C"'T �r Q • WESTGATE MFG., INC. 2041 Davie Avenue, Commerce, CA 90040 0 Phone (877) 805-2252 • Fax (877) 809-2252 WESTGATE THE FUTURE IS HERE ... AND IT'S QUITE BRIGHT! THUNDE FRIES LF-3BCW LF-30WW LF-3BRGB MODEL WATTS VOLTAGE LUMENS COLOR TEMP LF-30CW 30W 120/277V AC 2700 5000K LF-30WW 30W 120/277V AC 2650 3500K LF-30-RGB 30W 120/277V AC 2400 RGB PHOTOMETRIC& Test for LF-30CW Spectral Power Distribution JOB NAME: DATE: TYPE: CI LISTED ����� @8#*6TAR J Illuminance Plots Ilex oet11950 in ft 5 903E-002 3.2e11 L 5.247E-002 4.591E-002 3.935E-00Z 6.562ft 3.279E-002 LL 2.623E-002 1.96BE•002 -002 9.e43ft 1.312E 3■ 6.550E-0ai I 0.000E+000 350 400 450 500 550 600 650 700 750 B00 B50 900 950 1000 105C 13.12ft W&eleno 6. 16. 6ft 5. salght ■ev9, ds9 Angle:106.99deg Diameter Note:The Curves indieaea the illWnetad Brea and the overage illumination when the lumlnaire is at different distance. Luminous Intensity Distribution Plots -/+180 -150 150 -120 j`jr 120 C V OM:ad —CO/100,107.8° -30 30 — C30/210,108.5- —C60/260,110.6' 0 /270 112 3° AVBRAG/ REAM ANGLE(506):109.5 dw ' o ,o WESTGATE MFG., INC. 2041 Davie Avenue, Commerce, CA 90040 9 Phone (877) 805-2252 a Fax (877) 809-2252 o .' Certification of Compliance with Parking Lot Illumination Standards in Chapter 80-3 of the Code of Miami -Dade County Date: November 30, 2015 Re: Case Number: Folio: 11-2232-027-0120 Property Address: 1280 NE 105th St, Miami Shores FL 33138 — 9817 SF +/- Building Description: Multifamily Residential —16 Units The undersigned states the following: 1. 1 am a Florida registered professional engineer or architect with an active license. 1. On the evening of November 6, 2015, we measured the level of illumination in the parking lot(s) serving the above referenced building. 2. Maximum 9.0 foot candle per SF, Minimum 1.0 foot candle per SF; Minimum to Maximum ratio 1 : 9.0 , foot candle 1.4 average per SF. 3. The level of illumination provided in the parking lot(s) meets the minimum standards for the occupancy classification of the building as established in Section 8C-3 of the Code of Miami -Dade County. 4,e)j, (License) 1- FEB 0 5 r U 16 I 1280 NE 105th St Allied Building Inspection Services Inspections. Testing. Engineering Certification of Compliance with Parking Lot Illumination Standards in Chapter 8C-3 of the Code of Miami -Dade County Date: January 22, 2016 Re: Case Number: Folio: 11-2232-027-0120 Property Address: 1280 NE 105th St, Miami Shores FL 33138 — 9817 SF +/- Building Description: Multifamily Residential —16 Units The undersigned states the following, 1. 1 am a Florida registered professional engineer or architect with an active license. 2. On the evening of January 21, 2016, we measured the level of illumination in the parking lot(s) serving the above referenced building. 3. Maximum 3.1 foot candle per SF, Minimum 1.3 foot candle per SF; Minimum to Maximum ratio 1 : 2.4 , foot candle 2.0 average per SF. 4. The level of illumination provided in the parking lot(s) meets the minimum standards for the occupancy classification of the building as established in Section 8C-3 of the Code of Miami -Dade County. lt;_ LE Mark Reardon, RA 0017521 t 6,s3rd Reara'%% ��€-E-o_ -I- 8203 SW 12-11h Slreel, Miami, Florida 33156 * Tel: (305) 234-7377 * Fax: (303) 234-7664