Loading...
RCRT-17-2057BUILDING PERMIT APPLICATION Miami Shores Village Building Department AUG 15 Z017 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 ' Tel: (305) 795-2204 Fax: (305) 756-8972 t Y _ INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 200' Master Permit No. � �� ��— W5 I Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: CP S O KIE 09 i C r ra oe Cite: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11- ,37-W - b 11— 0I90 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: _ Flood Zone: BFE: FFE: OWNER: Name (Fee SimpleTitleholder)- i96 Jb fSO/G 11C 140nG�',-fn(7 Ott Phone#: �� - q55 -ZZ51 Address: f IC'120 &f ++ MAIL -A nc t'(f- (60-4Cl� v // Su i` 01 City: F a �IGcI�Ctf"l C �e.r-e h State: f-Lo ► i tl Tenant/Lessee Name: Email: CONTRACTOR: Company Name: Address: City: Qualifier Name: State Certification or Registration #: DESIGNER: Architect/Engineer: Address: Value of Work for this Permit: $ Phone#: Zip: Phone#: Certificate of Competency #: Phone#: City: State Square/Linear Footage of Work: Type of Work: ❑ Addiction ❑ Alteration New ❑ Repair/Replace Description of Work: -f [ e o r kit Lel� I caCLQri Specify color of color thru tile: /�, .sue Submittal Fee $ Zs V Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (RevisedO2/24/2014) CCF $_ DBPR $ 0 " -63do'q Zip: ❑ Demolition CO/CC $ _ Notary $ Double Fee $ _ Bond $ TOTAL FEE NOW DUE $ � / I Morandien AGmail.com FOLIO: 11-3206-011-0190 Date: 8-8-17 Ref; 650 NE 88 TER Miami Shores, FL 33138-3363 To: Miami -Dade County Building Official Miami -Dade County Department of Regulatory and Economic Resources Attention: Billing & Collection Unit Supervisor 11805 S.W. 26th Street, Room 149 Miami, Florida 33175-2474 Dear Building Official: A ccordance with Section §841(f) of the Code of Miami -Dade County, I have performed an =tion ofthe above referenced building, and determined that the building is structurally and trically safe for continued use under present occupancy. The findings of my inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification. This report does not preclude the building from subsequent inspections as deemed necessary by the Building Official. To avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of my knowledge and ability, this report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent reasonably possible. If you have q.ny questions, please do not hesitate to contact the undersigned. Respectfu , Enrique Morandi, P.E., G.C. President P.E. 36129, MEC COA 4728 Date: 8-8-17 i _4 APPR0VEc - BUILfANG f<`VIEW AF�FFc`?�,1❑ TI~ �� MIAMI• INSPECTION COMMENCED Date: 8-7-17 INSPECTION COMPLETED Date: 8-8-17 REGULATORY AND ECONOMIC RESOURCES DEPARTMENT INSPECTION MADE By: ENRIIQ�JE MPRANOI SIGNATURE• PRINT NAME: ENRIQUE MORANDI, P.E. 36129; MEC COA4728 TITLE: PRESIDENT: MORANDi FNGINEERING AND CONSTRUCTION, INC. ADDRESS: 930 SW 16 ST., BOCA RATON, FL 33486 TEL 954-461-9785 OR 5824 1. DESCRIPTION OF STRUCTURE a. Name on Title: 88 BISCAYNE MANAGEMENT LLC C/O CJ LAW b. Street Address: 650 NE 88 TER Miami Shores, FL 33138-3363 c. Legal Description:ASBURY PARK PB 4-110 LOT 19 LESS FED HWY d. Owner's Name: 88 BISCAYNE MANAGEMENT LLC C/O CJ LAW e. Owner's Mailing Address:1395 BRICKELL AVE 800 MIAMI, FL 33131 f. Folio Number of Property on which Building is Located: 1 1-3206-01 1-0190 g. Building Code Occupancy Classification: B h. Present Use: SHOPPING CENTER, RETAIL OUTLET i. General Description: 1-STORY CMU WITH CONCRETE COLUMNS, BEAMS, WOOD RAFTERS/SHEATHING ROOF ASSEMBLY. AREA= 9,537 Sq. Ft PER TAX RECORDS, CONSTRUCTION TYPE IS V. Addition Comments: NONE 2. PRESENT CONDITION OF STRUCTURE a. General alignment (Note: good, fair, poor, explain if significant) NONE VISIBLE 1. Bulging NONE VISIBLE 2. Settlement NONE VISIBLE 3. Deflections NONE VISIBLE 4. Expansion NONE VISIBLE 5. Contraction NONE VISIBLE b. Portion showing distress (Note, beams, columns, structural walls, floor, roofs, other) NONE VISIBLE c. Surface conditions — describe general conditions of finishes, noting cracking, spalling, peeling, signs of moisture penetration and stains. GOOD d. Cracks — note location in significant members. Identify crack size as HAIRLINE if barely discernible; FINE if less than 1 mm in width; MEDIUM if between 1 and 2 mm width; WIDE if over 2 mm, NONE VISIBLE ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8-8-17 e. General extent of deterioration — cracking or spalling of concrete or masonry, oxidation of metals; rot or borer attack in wood. NONE VISIBLE f. Previous patching or repairs SOME, HOLDING OK I g. Nature of present loading indicate residential, commercial, other estimate magnitude. SHOPPING CENTER, RETAIL OUTLET 3. INSPECTIONS a. Date of notice of required inspection MARCH, '17 b. Date(s) of actual inspection 8-7-17 8-8-17 c. Name and qualifications of individual submitting report: ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 d. Description of laboratory or other formal testing, if required, rather than manual or visual procedures NONE NEEDED e. Structural repair -note appropriate line: 1. None required 2. Required (describe and indicate acceptance) 4. SUPPORTING DATA a. ❑ sheet written data b. y photographs C. ❑ drawings or sketches ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8-8-17 S. MASONRY BEARING WALL = Indicate good, fair, poor on appropriate lines: a. Concrete masonry units GOOD b. Clay tile or terra cota units N-A C. Reinforced concrete tie columns GOOD d. Reinforced concrete tie beams GOOD e. Lintel GOOD f. Other type bond beams N-A g. Masonry finishes -exterior 1. Stucco 2. Veneer Ll 3. Paint only 4. Other (describe) h. Masonry finishes - interior 1. Vapor barrier 2. Furring and plaster 3. Paneling 4. Paint only s. Other (describe) GYPSUM WALL BOARDS BUISINESS INTERIORS i. Cracks NONE VISIBLE 1. Location — note beams, columns, other 2. Description j. Spalling NONE VISIBLE 1. Location — note beams, columns, other 2. Description k. Rebar corrosion -check appropriate line 1. None visible z 2. Minor -patching will suffice 3. Significant -but patching will suffice ENRIQUE MORANDI, P.F. 36129; MEC COA 4720 8-8-17 4. Significant -structural repairs required I. Samples chipped out for examination in spall areas: N-A 1. No El 2. Yes —describe color, texture, aggregate, general quality 6. FLOOR AND ROOF SYSTEM a. Roof 1. Describe (flat, slope, type roofing, type roof deck, condition) MIN. SLOPE WOOD RAFTERS/SHEATHING ROOF ASSY, IN GOOD CONDITION 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment and condition of ci innnrt- NONE 1 3. Note types of drains and scuppers and condition: FULLY OPEN ON LOW SIDE OF SLOPE b. Floor system(s) 1. Describe (type of system framing, material, spans, condition) SLAB ON GRADE, IN GOOD CONDITION. c. Inspection — note exposed areas available for inspection, and where it was found necessary to open ceilings, etc. for inspection of typical framing members. MEMBERS EXPOSED THROUGH ACCESS. 7. STEEL FRAMING SYSTEM a. Description ONLY PIPE STL COLS. SUPPORTING FRONT OVH. ENRIQUE MORANDI, P.E. 36129; MEC COA.4726 8-8-17 b. Exposed Steel- describe condition of paint and degree of corrosion GOOD c. Concrete or other fireproofing — note any cracking or spalling and note where any covering was removed for inspection N-A d. Elevator sheave beams and connections, and machine floor beams — note condition: N-A S. CONCRETE FRAMING SYSTEM a. Full description of structural system 1-STORY REINFORCED CMU WITH COLS. & TBMS. b. Cracking 1. Not significant ®^ 2. Location and description of members affected and type cracking c. General condition GOOD d. Rebar corrosion — check appropriate line 1. None visible 2. Location and description of members affected and type cracking 3. Significant but patching will suffice 4. Significant —structural repairs required (describe) e. Samples chipped out in spall areas: N-A 1. No 2. Yes, describe color, texture, aggregate, general quality: r� ENRIQUE MORANDI, P.E. 36129`9E'C )A 4728 B-8-17 9. WINDOWS a. Type (Wood, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted, fixed, other) i AL., STORE FRONT, F.G. b. Anchorage- type and condition of fasteners and latches GOOD c. Sealant —type of condition of perimeter sealant and at mullions: GOOD d. Interiors seals —type and condition at operable vents GOOD e. General condition: GOOD 10. WOOD FRAMING a. Type — fully describe if mill construction, light construction, major spans, trusses: ROOF RAFTERS/SHEATHING ONLY b. Note metal fitting i.e., angles, plates, bolts, split pintles, other, and note condition: GOOD c. Joints — note if well fitted and still closed: GOOD d. Drainage — note accumulations of moisture NONE e. Ventilation — note any concealed spaces not ventilated: NONE f. Note any concealed spaces opened for inspection: NONE js:Im:jg:rtc:10/13/2015:40yea rrecertificationsystem BORA Approved — Revised September 17, 2015/RER-10/13/2015 ENRIQUE MORANDI, P.E. 36129; .SEC COA 4728 8-8-17 MIAMI•Du4DE INSPECTION COMMENCED Date: 8-7-17 INSPECTION COMPLETED Date: 8-8-17 DESCRIPTION OF STRUCTURE DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES INSPECTION MADE BY: ENRI ' MO DI SIGNATURE: PRINT NAME: ENRIQUE MORANDI, P.E. 36129; MEO COA4728 TITLE: PRESIDENT: MORANDI ENGINEERING AND CONSTRUCTION, INC. ADDRESS: 930 SW 16 ST., BOCA RATON, FL 33486 TEL 954-461-9785 OR 5824 a. Name on Title: 88 BISCAYNE MANAGEMENT LLC C/O CJ LAW ;b. Street address: 650 NE 88 TER Miami Shores, FL 33138-3363 Imo. Legal Description: AS_BURY PARK PB 4-110 LOT 19 LESS FED HWY d. Owner's Name: 88 BISCAYNE MANAGEMENT LLC C/O CJ LAW e. Owner's Mailing Address:1395 BRICKELL AVE 800 MIAMI, FL 33131 P. Folio Number of Property on which Building is Located: 1 1-3206-01 1-0190 !g. Building Code Occupancy Classification: B Ih. Present Use: SHOPPING CENTER, RETAIL OUTLET li. General Description, Type of Construction, Size, Number of Stories, and Special Features Additional Comments: 1-STORY CMU WITH CONCRETE COLUMNS, BEAMS, WOOD RAFTERS/SHEATHING ROOF ASSEMBLY. AREA= 9,537 Sq. Ft PER TAX RECORDS, CONSTRUCTION TYPE IS V. NONE ELECTRIC/,' i-Vi- El. le -ter, t, -� , MINIMUM GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 1. ELECTRIC SERVICE 1. Size: Amperage 2. Phase: Three Phase 3. Condition: Good Comments: NONE 2. METER AND ELECTRIC ROOM 1. Clearances: Comments: NONE 3. GUTTERS ( 685 Fuses { ❑ ] Single Phase ( j Fair Good ( 7 ) Fair ( ❑ } Location: Go Good Taps and Fill: Good Comments: NONE ( ❑ ) Breakers { ® ] ( W } ( ❑ ) Needs Repair ( } Requires Correction ( ❑ ) ( } Requires Repair { } ( } Requires Repair ( y r C i ENRIQUE MORANDI, P.E. 129; MEC COA 4728 8-8-17 4. ELECTRICAL PANELS Location: Good 1. Panel #( 1 ) 2. Panel #( 2 ) Good 3. Panel #( 3 ( ) Needs Repair ( ) ( ) Needs Repair ( } ( ) Needs Repair ( ) Good ( ® ) Needs Repair ( ) .4. Panel #( 4 ) Good ( ) Needs Repair ( } 115. Panel #( 5+ ) Good ( ) Needs Repair ( } Comments: NONE 5. BRANCH CIRCUITS: 1. Identified: Yes ( ❑v ) Must be identified ( ) 2. Conductors: Good ( ® ) Deteriorated ( ) Must be replaced (El ) Comments: NONE ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8-8-17 6. GROUNDING SERVICE: Good ( ) Repairs Required ( ) Comments: NONE 7. GROUNDING OF EQUIPMENT: Good ( } Repairs Required (Fl ) Comments: NONE 8. SERVICE CONDUITS/RACEWAYS: Good F, (I ) Repairs Required ( ) Comments: NONE 9. SERVICE CONDUCTOR AND CABLES: Comments: NONE Good t ) Repairs Required ( ) t� ENRIQUE MORANDI, P.E. 36129; MEG COA 4728 8-8-17 10. TYPES OF WIRING METHODS: Conduit Raceways: Good ( j Repairs Required [ ) Conduit PVC: Good ( } Repairs Required [ ) NM Cable: N-A Good { } Repairs Required ( ) BX Cable: Good Repairs Required ( ) 11. FEEDER CONDUCTORS: Good ( ) Repairs Required ( } Comments: NONE 12. EMERGENCY LIGHTING: Good ( ® } Repairs Required ( 1J } Comments: NONE 13. BUILDING EGRESS ILLUMINATION: Good ( ® } Repairs Required [ } Comments: NONE ENRIQUE MORANAP.E.29; MEC COA 4728 8-8-17 14. FIRE ALARM SYSTEM: Good ( ® ) Repairs Required I r-1 ) Comments: NONE 15. SMOKE DETECTORS: Good Comments: NONE 16. EXIT LIGHTS: Good Comments: NONE 17. EMERGENCY GENERATOR: Good Comments: N-A ( ® 7 Repairs Required ( ) ( [;�] ) Repairs Required (. ) ( ❑ ) Repairs Required ( ❑ ) ENRIQUE MORANDI, P.E. 3E12.ci; MEC COA 4728 8-8-17 18. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS: Require Additional Good ( } Repairs Required Comments: ALL LIGHTS ON BLDG. WALLS 19. OPEN OR UNDERCOVER PARKING GARAGE AREAS AND EGRESS ILLUMINATION: Require Additional Comments: NONE 20. SWIMMING POOL WIRING: Comments: N-A � � 1 Good ( ) Repairs Required { } Good ( ) Repairs Required ( ❑ ) 21. WIRING TO MECHANICAL EQUIPMENT: Good Comments: NON E { ® j Repairs Required (❑ ) ENRIQUE MORANDI, R.E. 36129; MEC COA 4728 8-8-17 22. ADDITIONAL COMMENTS: S D: rs: vc:m b:js:j g: rtc1:10/12/2015:40yrtracki ng system ENRIQUE MORANDI, P.E. 26129; Il9EC COA 4728 8-8-17 CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTY Date: 8-8-17 RE: Case No.: FOLIO: 11-3206-011-0190 Property Address: 660 NE 88 TER Miami Shores, FL 33138-3363 Building Description: 1-STORY CMU WITH CONCRETE COLUMNS, BEAMS, 1. 1 am a Florida registered professional engineer or architect with an active license. 2. On 8-6 . 2017 , at 9:20 pm, I measured the level of illumination in the parking lot (s) serving the above referenced building. 3. Maximum 3.1 foot candle per SF, Minimum 1_0 Minimum to Maximum ratio 3,1 : , foot candle 2 foot candle per SF, average per SF. 4. The level of illumination provided in the parking lot (s) meets / doeQt meet the minimum standards for the occupancy classification of the building as established in Section 8C-3 of the Code of Miami -Dade County. EQUIPMENT USED: LG17010 Hydrofarm Digital Light Meter Signature and Sea! of Architect or Engineer ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 (Print Name) ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8.8-17 CERTIFICATION OF COMPLIANCE WITH PARKING LOT GUARDRAILS REQUIREMENTS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTY DATE: a-8-17 FOLIO: 11-3206-011-0190 Re: Case No. Property Address: Bldg. No.: , Sq. Ft.: 650 NE 88 TER Miami Shores, FL 33138-3363 Building Description: 1-STORY CMU WITH CONCRETE COLUMNS, BEAMS, The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. On 8-6 , 2017 , I inspected the parking lots servicing the above referenced building for compliance with Section 8C-6 and determined the following (check only one): ® The parking lot(s) is not adjacent to or abutting a canal, lake or other body of water. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are not protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. I have advised the property owner that he/she must obtain a permit for the installation of the guardrail and obtain al! required inspection approvals to avoid enforcement action. Signature and Seal of Architect or Engineer ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 (Print Name) ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8-8-17'- - -