Loading...
RCRT-17-2056Miami Shores Tillage auG0�7 Building Department .,,J__,�,;� 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 t INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION dBUILDING dELECTRIC ❑ ROOFING ❑PLUMBING ❑ MECHANICAL ❑PUBLICWORKS JOB ADDRESS: W!�. l FBC 2011 sVI Master Permit No. (C P�T 0 — 2-0s6 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS City: Miami Shores J County'. Miami Dade Zip: �3139 Folio/Parcel#: 1 I '— Q[.0- D 1 Z — O020 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: __ Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder : 1 3L Address: I� F f l�►��� - 0�L� City: E10ande4kc -Regck State: Tenant/Lessee Name: Email: CONTRACTOR: Company Name: Phone#: Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State:. Zip: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration I --]New ❑ Repair/Replace ❑ Demolition Description of Work: 40 Aoy kt-e IibcOA ion Specify color of color thru tile: Submittal Fee $ �� Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) CCF $_ DBPR $ CO/CC $ Notary $ Double Fee $ _ Bond $ TOTAL FEE NOW DUE $ I. &j Morandieric AGmail.com FOLIO: 11-3206-012-0020 Date: 8/8/17 Ref; 8851 BISCAYNE BLVD Miami Shores, FL 33138-0000 To: Miami -Dade County Building Official Miami -Dade County Department of Regulatory and Economic Resources Attention: Billing & Collection Unit Supervisor 11805 S.W. 26th Street, Room 149 Miami, Florida 33175-2474 Dear Building Official: Jaccordance with Section §8-11(f) of the Code of Miami -Dade County, I have performed an / n 'tion of the above referenced building, and determined that the building is structurally and electrically safe for continued use under present occupancy. The findings of my inspection are summarized in this written report that follows the Minimum Inspection Procedural Guidelines for Building Recertification. This report does not preclude the building from subsequent inspections as deemed necessary by the Building Official. To avoid possible misunderstanding, nothing in this report should be construed directly or indirectly as a guarantee for any portion of the structure. To the best of my knowledge and ability, this report represents an accurate appraisal of the present condition of the building based upon careful evaluation of observed conditions, to the extent reasonably possible. If you have any questions, please do not hesitate to contact the undersigned. Respectfully, Enrique Morandi, P.E., G.C. President P.E. 36i29, MEC COA 4728 Date: 8/8/17 r F :�iLDING REVIEW ;APPROVED - MIAMF ,a INSPECTION COMMENCED Date: 8-7-17 INSPECTION COMPLETED Date: 8/8/17 1. DESCRIPTION OF STRUCTURE REGULATORY AND ECONOMIC RESOURCES DEPARTMENT INSPECTION MADE BY: ENRIQUE MORANDI SIGNATURE: PRINT NAME: ENRIQUE MORANDI, P.E. 36129; MEC COA4728 TITLE: PRESIDENT: MCRANDI ENGINEERING AND CONSTRUCTION, INC. ADDRESS: 930 SW 16 ST., BOCA RP.TON, FL 33486 TEL 954-461-9785 OR 5824 f a. Name on Title:88 BISCAYNE MANAGEMENT LLC C/O CJ LAW b. Street Address:8851 BISCAYNE BLVD Miami Shores, FL 33138-0000 c. Legal Description: FARMINGTON SUB PB 48-17 LOT 4 d. Owner's Name: 88 BISCAYNE MANAGEMENT LLC C/O CJ LAW e. Owner's Mailing Address:1395 BRICKELL AVE 800 MIAMI, FL 33131 f. Folio Number of Property on which Building is Located: 1 1-3206-012-0020 g. Building Code Occupancy Classification: B h. Present Use: RETAIL OUTLET i. General Description: 1-STORY CMU WITH CONCRETE COLUMNS, BEAMS, WOOD RAFTERS/SHEATHING ROOF ASSEMBLY. AREA= 6,084 Sq. Ft PER TAX RECORDS, CONSTRUCTION TYPE IS III. J Addition Comments: NONE j. Additions to original structure: NONE 2. PRESENT CONDITION OF STRUCTURE a. General alignment (Note: good, fair, poor, explain if significant) NONE VISIBLE 1. Bulging NONE VISIBLE 2. Settlement NONE VISIBLE 3. Deflections NONE VISIBLE 4. Expansion NONE VISIBLE s. Contraction NONE VISIBLE b. Portion showing distress (Note, beams, columns, structural walls, floor, roofs, other) NONE VISIBLE c. Surface conditions — describe general conditions of finishes, noting cracking, spalling, peeling, signs of moisture penetration and stains. GOOD d. Cracks — note location in significant members. Identify crack size as HAIRL.MF. if barely discernible; FINE if less than 1 mm in width; MEDIUM if between 1 and 2 mm width; WIDE if over 2 mm. NONE VISIBLE ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8/8/17 e. General extent of deterioration — cracking or spalling of concrete or masonry, oxidation of metals; rot or borer attack In wood. NONE VISIBLE f. Previous patching or repairs SOME, HOLDING OK g. Nature of present loading indicate residential, commercial, other estimate magnitude. RETAIL OUTLET 3. INSPECTIONS a. Date of notice of required inspection MARCH, '17 b. Date(s) of actual inspection 8-7-17 8/8/17 c. Name and qualifications of individual submitting report: ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 d. Description of laboratory or other formal testing, if required, rather than manual or visual procedures NONE NEEDED e. Structural repair -note appropriate line: 1. None required 2. Required (describe and indicate acceptance) 4. SUPPORTING DATA a• 1:1 sheet written data b• ® photographs C. drawings or sketches r ENRIQUE MORANDI, P.E. 8 9; MEC COA 4728 8/8/17 S. MASONRY BEARING WALL = Indicate good, fair, poor on appropriate lines: a. Concrete masonry units GOOD b. Clay tile or terra cota units N-A c. Reinforced concrete tie columns GOOD d. Reinforced concrete tie beams GOOD e. Lintel GOOD f. Other type bond beams N-A g. Masonry finishes -exterior 1. Stucco 2. Veneer 3. Paint only 4. Other (describe) h. Masonry finishes - interior 1. Vapor barrier 2. Furring and plaster El 3. Paneling El 4. Paint only 5. Other (describe) Ff GYPSUM WALL BOARDS BUISINESS INTERIORS i. Cracks NONE VISIBLE 1. Location — note beams, columns, other 2. Description j. Spalling NONE VISIBLE 1. 2. Location — note beams, columns, other Description k. Rebar corrosion -check appropriate line 1. 2. None visible Minor -patching will suffice ❑ 3. Significant -but patching will suffice ❑ ENRIQUE MORAN71, P. 36125, MEC COA 4728 8/8/17 4. Significant -structural repairs required I. Samples chipped out for examination in spall areas: N-A 1. No 2. Yes —describe color, texture, aggregate, general quality 6. FLOOR AND ROOF SYSTEM a. Roof 1. Describe (flat, slope, type roofing, type roof deck, condition) MIN. SLOPE WOOD RAFTERS/SHEATHING ROOF ASSY, IN GOOD CONDITION 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment and condition of support: NONE 3. Note types of drains and scuppers and condition: FULLY OPEN ON LOW SIDE OF SLOPE b. Floor system(s) 1. Describe (type of system framing, material, spans, condition) SLAB ON GRADE, IN GOOD CONDITION. c. Inspection — note exposed areas available for inspection, and where it was found necessary to open ceilings, etc. for inspection of typical framing members. MEMBERS EXPOSED THROUGH ACCESS. 7. STEEL FRAMING SYSTEM a. Description N-A ENRIQUE MORANM, P.E: 335129, MEC COA 4728 8/8/17 b. Exposed Steel- describe condition of paint and degree of corrosion GOOD c. Concrete or other fireproofing — note any cracking or spalling and note where any covering was removed for inspection N-A d. Elevator sheave beams and connections, and machine floor beams — note condition: N-A S. CONCRETE FRAMING SYSTEM a. Full description of structural system 1-STORY REINFORCED CMU WITH COLS. & TBMS. b. Cracking 1. Not significant 2. Location and description of members affected and type cracking c. General condition GOOD d. Rebar corrosion — check appropriate line 1. None visible 2. Location and description of members affected and type cracking 3. Significant but patching will suffice 4. Significant —structural repairs required (describe) e. Samples chipped out in spall areas: N-A 1. No 2. Yes, describe color, texture, aggregate, general quality: ENRIQUE MORANDI, P: .�;K:_9.7RgrCC�A 4728 8/8/17 9. WINDOWS a. Type (Wood, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted, fixed, other) AL., STORE FRONT, F.G. b. Anchorage- type and condition of fasteners and latches GOOD c. Sealant — type of condition of perimeter sealant and at mullions: GOOD d. Interiors seals —type and condition at operable vents GOOD e. General condition: GOOD 10. WOOD FRAMING a. Type — fully describe if mill construction, light construction, major spans, trusses: ROOF RAFTERS/SHEATHING ONLY b. Note metal fitting i.e., angles, plates, bolts, split pintles, other, and note condition: GOOD c. Joints — note if well fitted and still closed: GOOD d. Drainage — note accumulations of moisture NONE e. Ventilation — note any concealed spaces not ventilated: NONE f. Note any concealed spaces opened for inspection: NONE js:ImJg:rtc:10/13/2015:40yearrecertificationsystem BORA Approved — Revised September 17, 2015/RER-10/13/2015 ENRIQUE MORANDI, P.E. 36129-7 MEC COA 4728 8/8/17 M IAM ,a INSPECTION COMMENCED Date: 8-7-17 INSPECTION COMPLETED Date: 8/8/17 DESCRIPTION OF STRUCTURE DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES INSPECTION MADE BY: ENR Nf]I SIGNATURE: PRINT NAME: ENRIQUE MORANDI, P.E. 36129; NEG COA 4728 TITLE: PRESIDENT: MORANDI ENGINEERING AND CONSTRUCTION, INC. ADDRESS: 930 SW 16 ST., BOCA RATON, FL 33486 TEL 954-461-9785 OR 5824 a. Name on Title: 88 BISCAYNE MANAGEMENT LLC C_/O CJ LAW ,b. Street address: 8851 BISCAYNE BLVD Miami Shores, FL 33138-0000 c. Legal Description: FARMINGTON SUB PB 48-17 LOT 4 d. owner's Name: 88 BISCAYNE MANAGEMENT LLC C/O CJ LAW le. Owner's Mailing Address:1395 BRICKELL AVE 800 MIAMI, FL 33131 f. Folio Number of Property on which Building is Located: 1 1-3206-012-0020 g. Building Code Occupancy Classification: B Ih. Present Use: RETAIL OUTLET i'. General Description, Type of Construction, Size, Number of Stories, and Special Features Additional Comments: 1-STORY CMU WITH CONCRETE COLUMNS, BEAMS, WOOD RAFTERS/SHEATHING ROOF ASSEMBLY. AREA= 6,084 S . Ft PER TAX RECORDS, CONSTRUCTION TYPE IS III. NONE LLF—CTR1UALREV1EzVV APPROVED s' DATE MINIMUM GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY (40) YEAR STRUCTURES 1. ELECTRIC SERVICE 1. Size: Amperage 2. Phase: Three Phase 3. Condition: Goo ( 700 Fuses { ® } Single Phase { } Fair Comments: 3-200A 1 PH & 1-100A 3PH, ALL GOOD. 2. METER AND ELECTRIC ROOM 1. Clearances: Good ( ® ) Comments: NONE 3. GUTTERS { ❑ ) Breakers l ® } [ ) Needs Repair ( ❑ ] Fair ( ❑ ) Requires Correction ( ) Location: Go Good ( ) Requires Repair { } Taps and Fill Good { f Requires Repair [ Comments: N-A ENRIQUE MORANDI, P.E. 36129; MEC CC A 4728 8/8/17 4. ELECTRICAL PANELS Location: Good 11. Panel #( 1 ) Good Panel #( 2 ) Good 3. Panel #( 3 4 Panel #( 4 ) 5. Panel #( ) Comments: NONE ( ® ) Needs Repair ( ) ( [;�] ) Needs Repair ( ) ( F,� r] ) Needs Repair ( ❑ ) Good ( F,—�, ] ) Needs Repair ( ) Good ( ® ) Needs Repair Good ( ❑ ) Needs Repair ( ) 5. BRANCH CIRCUITS: 1. Identified: Yes 2. Conductors. Good Comments: Mrw= ( ® ) Must be identified ( ) ( ® ) Deteriorated ( ) Must be replaced ( ) ENRIQUE MORANDI, F.E. 36129; M-EC COA 4728 818/17 J 6. GROUNDING SERVICE: Good Comments: NONE 7. GROUNDING OF EQUIPMENT: Good Comments: NONE 8. SERVICE CONDUITS/RACEWAYS: Comments: NONE 9. SERVICE CONDUCTOR AND CABLES: Good Comments: NONE ( Fv 7] ) Repairs Required ( ❑ ) ( ® ) Repairs Required ( ) { ® } Repairs Required ( ) ( F,71 ) Repairs Required ( ❑ ) ENRIQUE MORANDI, P.E. 06129; MEC COA 4728 8/8/17 10. TYPES OF WIRING METHODS: Conduit Raceways: Good ( v❑ ) Repairs Required ( ) Conduit PVC: Good ( ) Repairs Required ( ) NM Cable: N-A Good ( ) Repairs Required ( ) BX Cable: N-A Good ( ) Repairs Required ( ) 11. FEEDER CONDUCTORS: Good [ ® } Repairs Required ( ) Comments: NONE 12. EMERGENCY LIGHTING: Good [ ® ) Repairs Required ( j Comments: NONE i 13. BUILDING EGRESS ILLUMINATION: Good { ® } Repairs Required ( } Comments: NONE i ENRIQUE MORANDI, P.E. 36 � 29; MEC COA 4728 8/8/17 14. FIRE ALARM SYSTEM: Good [ } Repairs Required ( ) Comments: NONE 15. SMOKE DETECTORS: Good ( ® ) Repairs Required ( ) Comments: NONE 16. EXIT LIGHTS: Good ( ® ) Repairs Required ( 7 Comments: NONE 17. EMERGENCY GENERATOR: Good Comments: N-A ( ) Repairs Required ( ) ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8/8/17 18. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS: Require Additional Good j Repairs Required ❑ J Comments: ALL LIGHTS ON BLDG. WALLS 19.OPEN OR UNDERCOVER PARKING GARAGE AREAS AND EGRESS ILLUMINATION: Require Additional Good Comments: NONE 20. SWIMMING POOL WIRING: J Repairs Required ❑ J Good ( ) Comments: N-A 21. WIRING TO MECHANICAL EQUIPMENT: Good Comments: NONE 9-00 Repairs Required ( ❑ ) Repairs Required ( Ej ) ENRIQUE MORANDI, P.E. 36 ,29; MEC COA 4728 8/8/17 22. ADDITIONAL COMMENTS: S D: rs:vc: mb:js:jg: rtc1:10/12/2015:40yrtrackingsystem ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8/8/17 CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTY Date: 8-8-17 RE: Case No.: FOLIO: 11-3206-012-0020 Property Address: 8851 BISCAYNE BLVD Mlaml Shores, FL 33138-0000 Building Description: 1-STORY CMU WITH CONCRETE COLUMNS, BEAMS, 1. 1 am a Florida registered professional engineer or architect with an active license. 2. On 8-6 _ 2017 , at 9:35 pm, I measured the level of illumination in the parking lot (s) serving the above referenced building. 3. Maximum 3.8 foot candle per SF, Minimum 1 0 foot candle per SF, Minimum to Maximum ratio s-s foot candle 2.4 average per SF- 4. The level of illumination provided in the parking lot (s) meets / doeQt meet the minimum standards for the occupancy classification of the building as established in Section 8C-3 of the Code of Miami -Dade County. EQUIPMENT USED: LG17010 Hydrofarm Digital Light Meter i Signature and Seal of Architect or Engineer ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 (Print Name) ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 8/8/17` CERTIFICATION OF COMPLIANCE WITH PARKING LOT GUARDRAILS REQUIREMENTS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTY DATE: 8-8-17 FOLIO: 11-3206-012-0020 Re: Case No. Property Address: Bldg. No.: , Sq. Ft.: 8851 BISCAYNE BLVD Miami Shores, FL 33138-0000 Building Description: 1-STORY CMU WITH CONCRETE COLUMNS, BEAMS, The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. On 8-6 .2017 , 1 inspected the parking lots servicing the above referenced building for compliance with Section 8C-6 and determined the following (check only one): The parking lot(s) is not adjacent to or abutting a canal, lake or other body of water. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are not protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. I have advised the property owner, that he/she must obtain a permit for the installation of the guardrail and obtain all required inspection approvals to avoid enforcement action. AV - Signature and Seal of Architect or Engineer ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 (Print Name) ENRIQUE MORANDI, P.E. 36129; MEC COA 4728 818117