Loading...
RCRT-16-492Miami Shores Village RECEIVED Building Department JUN 07 2018 1c 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 F BUILDING Master Permit No. V— C 2-T t(P ` Q 2 PERMIT APPLICATION Sub Permit No. f JBUILDING ❑ ELECTRIC 1 ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP / CONTRACTOR DRAWINGS JOB ADDRESS: City: Miami Shores Count Miami Dade Zi ; Folio/Parcel#: Is the Building Historically Designated: Yes NO OccupancyT aa04 Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Address: 3 City: `1' State: Zip: Tenant/Lessee Name: 44 Phone#: Email: CONTRACTOR: Company Name: 9ALLIL Phone#:m Address: City: State: Zip_ Qualifier Name: _ Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: ` Address. City: State: Zip: Value of Work for this Permit: $_ Square/Linear Footage of Work: Type of Work: ❑ Additio ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: 4±1,P)l /I Specify color of color thru tile: Submittal Fee $ Permit Fee $ 3� CCF $_ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ _ Bond $ 20 1-4 - 400, a Z01C9 : 3CpO�3 TOTAL FEE NOW DUE $ (Revised02/24/2014) c �� J 0 7 $ w I rlj I w I » I N o c o c c e _ e w o « v c Ln v < 2 w , L \ f \ c g / \ R P k \ �, 0 :n z r LO 0) to M11 0 N 0 N 0 T.7 O IV 0 h' 06 I--• V F" a) +- Q7 0 Ul C m V: N O N Q u G-ti 7[7 :0 -0 N � Q+ LM � tD alp -S N C] Q In 0 � o O o O o a v C CD Ci. TLa13R_IDA t3iTa W C31;. 4WE "IV G I ti G+ >Cr at 5 da I �i PJ >P 1C G '�' �O ri C I Ty � G V C.��I"CD "Sel.\fincg' Fj.=,rici� Coast to Cost.• 8 i i- S 9 4 -- $ 0 Q 1 2019 12555 Biscayne Blvd. # 934 JUN 0 7t � Mayr rtMiami. FL 33181 ��� \CPY O 1. RE: Folio # 11-3206-014-1561 OWNER NAME: LESTER EUGENE DONALDSON GRACE DONALDSON PROPERTY ADDRESS: 705 NE 92 ST MIAMI SHORES, FL 33138 DATE OF INSPECTION: June 1, 2018 TO: MIAMI SHORES BUILDING DEPARTMENT OFFICIAL On behalf of the above -mentioned property owner I would like to respeZ,ful,y requ--a. that Recertification per Miami -Dade county Ordinance NO. 75-34 (amended by Ordinance 92-1) be granted to the above -mentioned structure. have inspected the above -mentioned property and find the building "jtracturally rr-d electrically" safe for its intended use and occupancy". As routine matter, in order to avoid possible misunderstanding, nothing in the reoorL attached should be construed directly, or indirectly as a guarantee for any portion of the structure. Future function is not guaranteed in any way. To the best of my ability Li.d knowledge this report represents an accurate appraisal of the present conditions of the building(s) based upon careful evaluation of the observed conditions, to the extent reasonably possible. Thank you for your attention to this matter. Sincere, Gordon W. Myers PE 6852��"'� Florida Builders, Engineers & Inspectors, Inc. A Professional Engineering Firm CA 31260 6-1-2018 _�.2-TICp-�q2 ._fir; iT _ `f _ M:E.mi Shr_,�; Vill,-_j(,e r APB ROBED 8Y DATE 7.ONING pP�� DLDG E~EPT 6% o ccklpl.vf )) wl rl-i Al_L �, l `TATEAN,_,(_( iN,(,ltj__5ANDRFGIJLAfICi'iS s� Although this Letter of Recertification allows continued occupancy ofthe building, issuance of this letter should not be construed directly or indirectly as a guarantee of the safety/ code compliance of any portion of the structure. . W F'LQR.I1s I r I3.PU- 7E1Z S 4W IF, ?V G i ._V .E Jr- Ws S 5� \ S G' 'i' O R S "Siarving FIc7r'ic a CrZ�etst tc) C-C�aSt•. 8 7 7- 8 9 4- S O O 1 12555 13iscayne Blvd- #t 934 North Miami, FL 33181 BUILDING DEPARTMENT MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING'S ELECTRICAL RECERTIFICATION BUILDING DEPARTMENT INSPECTION COMMENCED INSPECTION MADE BY: DATE: 6-1-2018 Florida Builders Engineers & Inspectors Gordon W Myers PE 36552 /CA 31260 INSPECTION COMPLETED 12555 Biscayne Blvd #934 DATE: 6-1-2018 North Miami, Florida 33131 Tel: (305) 895-8001/ Fax: (�jbS) 895-7001 Name of Title: LESTER EUGENE DONALDSON GRACE DONALDSON Street Address: 705 NE 92 ST MIAMI SHORES, FL 33138 Legal Description: 5 6 53 42 MIAMI SHORES SEC 3 PB 10-37 PARTS OF LOTS 22-23 BEG 25FTE OF SW COR LOT 22 E75FT NW135FT W57F T SEI31.23FT TO POB BLK 63 LOT SIZE 66.000 X 130 OR 19740-2237 06 2001 1 COC 25316-0590 06 2006 5 Owner's Name: LESTER EUGENE DONALDSON GRACE DONALDSON Owner's Mailing Address: 705 NE 92 ST 2 MIAMI SHORES, FL 33138 Folio Number of Building: 11-3206-014-1561 Building Code Occupancy Classification: 0803 MULTIFAMILY 2-9 UNITS: MULTIFAMILY 3 OR MORE UNITS Present Use: 4 RESIDENTIAL UNITS General Description, Type of Construction, Size, Number of Stories, Features: CBS (2) STORY TOTAL ADJ. AREA 4,789 SQ FT ACCORDING TO P. REC r 6-1-2018 Wj GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY(44 YEAR STRUCTURES 1. ELECTRIC SERVICE 1. Size: Amperage 4 (100) Fuses ( ) Breakers (X) 2. Phase: Three Phase ( ) Single ( X ) 3. Condition: Good ( X ) Fair ( ) Needs Repair ( ) 4. Comments: MAIN DISCONNECT LOCATED AT METER ROOM ELECTRICAL PANELS/ ELEMENTS HAVE WEAR DUE TO AGE AND USE; HOWEVER THEY ARE OPERABLE AT THIS TIME AND IN FAIR CONDITION. CONTINUED MAINTENANCE IS SUGGESTED TO ENSURE PROPER AND CONTINUED OPERATIONS. UN -EXPOSED ELECTRICAL ELEMENTS WERE NOT INSPECTED; ONLY THOSE ELEMENTS THAT WERE VISBLE AT THE TIME OF THE INSPECTION WERE INSPECTED 2. METER AND ELECTRICAL ROOM: 1. Clearance: Good (X) Fair ( ) Requires Correction ( ) 2. Comments: METER ROOM PRESENT AT THIS BUILDING 3. GUTTERS 1. Location: Good (X) Requires Repair ( 1 2. Taps and fill: Good (X) Requires Repair ) 4. ELECTRICAL PANELS--, .. . 1. Panel # (1-4 ) Location: INSIDE EACH UNIT 2. Panel # ( ) Location: 3. Panel # ( ) Location: 4. Panel # ( ) Location: 5. Panel # ( ) Location: 6. Panel # ( ) Location: 7. Panel # ( ) Location: 8. Panel # ( ) Location: Conditions: Good (X ) Comments: 6-1-2018 Requires Repairs ( ) 3 5. BRANCH CIRCUITS 1. Identified: Yes (X) Must be identified ( ) 2. Conductor: Good ( X ) Deteriorated ( ) Must be Replaced ( ) 3. Comments: 6. GROUNDING OF SERVICE Condition: Good (X ) Repairs Required ( ) Comments: 7. GROUNDING OF EQUIPMENT Condition: Good (X ) Repairs Required ( ) Comments: 8. SERVICE CONDUITS/RACEWAYS Condition: Good ( X ) Repairs Required ( ) Comments: 9. SERVICE CONDUCTORS AND CABLES Condition: -----Good ( X ) Repairs Required ( ) Comments: 10. TYPES OF WIRING METHODS Condition: Conduit Raceways: Good (X) Repairs Required ( ) Conduit PVC: Good (X) Repairs Required ( ) NM Cables: Good ( ) Repairs Required ( ) BX Cables: Good ( ) Repairs Required ( ) 11. FEEDER CONDUCTORS Condition: Good ( X ) Comments: 12. EMERGENCY LIGHTING Condition: Good ( ) Comments: N/A Repairs Required ( ) Repairs Required ( ) 13. BUILDING EGRESS ILLUMINATION Condition: Good ( X) Repairs Required ( ) Comments: - 14. FIRE ALARM SYSTEM Condition: Good ( ) Repairs Required ( ) Comments: N/A 6-1-2018 / AV �� 4 15. SMOKE DETECTORS Condition: Good ( X) Repairs Required ( ) Comments 16. EXIT LIGHTS Condition: Good ( ) Repairs Required ( ) Comments: N/A 17. EMERGENCY GENERATOR Condition: Good ( ) Repairs Required ( ) Comments: N/A 18. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS Condition: Good (X) Repairs Required ( ) Comments: 19. OPEN OR UNDERCOVER PARKING SURFACE AND SECURITY LIGHTING Condition: Good (X) Repairs Required ( ) Comments: 20. SWIMMING POOL WIRING Condition: Good ( ) Repairs Required ( ) Comments: N/A 21. WIRING OF MECHANICAL EQUIPMENT Condition: Good (X ) Repairs Required ( ) Comments: GENERAL ADDITIONAL COMMENTS: Continued maintenance is suggested to maintain proper function. Inspection is made to what is readily visible and accessible only. AS A ROUTINE MATTER, AND IN ORDER TO AVOID POSSIBLE MUSUNDERSTANDING NOTHING IN THIS INSPECTION REPORT FORM ATTACHED MINIM•UMJNSPECTION GUIDELINES AND OUR NON-DESTRUCTIVE OBSERVATION SHOULD BE CONSTRUED DIRECTLY OR INDIRECTLY, AS A GUARANTEE OR WARRANTEE OF ANY PORTION OF THE STRUCTURE. TO THE BEST OF MY KNOWLEDGE AND ABILITY THIS REPORT REPRESENTS AN ACCURATE APPRAISAL OF THE PRESENT CONDITION OF THE STRUCTURE BASED UPON CAREFUL EVALUATION OF THE OBSERVED CONDITIONS TO THE EXTENT REASONABLY POSSIBLE. 6-1-2018 5 E\ G II -NZ E E 1 S I' E G T O R S "Serving Florida Coast to Coast" 8 7 7- 8 9 4- 8 O O 1I 125SS Biscayne Blvd_ 4 934 North Miami, FL 33181 BUILDING DEPARTMENT MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING'S STRUCTURAL RECERTIFICATION BUILDING DEPARTMENT INSPECTION COMMENCED INSPECTION MADE BY: DATE: 6-1-2018 Florida Builders Engineers & Inspectors Gordon W Myers PE 36R52 /C'A 31260 INSPECTION COMPLETED 12555 Biscayne Blvd #934 DATE: 6-1-2018 North Miami, Florida 33191 Tel: (305) 895-8001/ Fax: (305) 895-7001 Name of Title: LESTER EUGENE DONALDSON GRACE DONALDSON Street Address: 705 NE 92 ST MIAMI SHORES, FL 33138 Legal Description: 5 6 53 42 MIAMI SHORES SEC 3 PB 10-37 PARTS OF LOTS 22-23 BEG 25FTE OF SW COR LOT 22 E75FT NWI3`FT W57FT SEI31.23FT TO POB BLK 63 LOT SIZE 66.000 X 130 OR 19740-2237 06 2001 1 COC 25316-0590 06 2006 5 Owner's Name: LESTER EUGENE DONALDSON GRACE DONALDSON Owner's Mailing Address: 705 NE 92 ST 2 MIAMI SHORES, FL 33138 Folio Number of Building: 11-3206-014-1561 Building Code Occupancy Classification: 0803 MULTIFAMILY 2-9 UNITS: MULTIFAMILY 3 OR MORE UNITS Present Use: 4 RESIDENTIAL UNITS General Description, Type of Construction, Size, Number of Stories, Features: CBS (2) STORY TOTAL ADJ. AREA 4,789 SQ FT ACCORDING TO P. REC 6-1-2018 el AV 9 ADDITIONS TO ORIGINAL STRUCTURE: No visible additions noted to original structure at this time. This determination is made on what is visible and accessible at the site with no inquiry to construction plans and or microfilms. 2. PRESENT CONDITION OF STRUCTURE a. General alignment (not good, fair, poor, explain if significant) FAIR 1. Bulging NONE 2. Settlement NONE 3. Defections NONE 4. Expansion NONE 5. Contraction NONE b. Portions showing distress (note beams, columns, structural walls, floors, roofs) NONE VISIBLE C. Surface conditions- describe general conditions of finishes, cracking, spalling, peeling signs of moisture penetration & stains: FAIR d. Cracks- note location in significant members. Identify crack size as HAIRLINE if barely dissemble; FINE if less than 1 trim in width; MEDIUM ifbetween 1 and 2 mm in width; WIDE ifover 2 mm. FINE e. General extent of deterioration —cracking or spall ing of concrete or masonry; oxidation of metals; rotor borer attack in wood. N/A f. Previous patching or repairs: YES g. Nature of present loading; indicate Residential, Commercial, other magnitude. 3. INSPECTIONS a. Date ofnotice ofrequired inspection: 2018 b. Date(s) ofactual inspection: 6-1-2018 c. Name and qualification of individual submitting report: Gordon W. Myers PE 36852 d. Description of any laboratory or other formal testing, if required, rather than manual or visual procedures: N/A e. Structural repair note appropriate line: 1. None Required XXXXXXX 2, Required (describe and indicate acceptance) 4. SUPPORTING DATA a. NIA Sheet written data b. N/A Photographs C. NIA Drawings or sketches 5. MASONRY BEARING WALL = Indicate good, fair, poor on appropriate lines: a. Concrete masonry units: FAIR b. Clay tile or terracotta units: NONE c. Reinforced concrete tile columns: FAIR d. Reinforced concrete tile beams: FAIR e. Lintel: FAIR f. Other type bond beams FAIR g. Masonry finishes — exterior FAIR 1. Stucco FAIR 2. Veneer N/A 3. Paint Only FAIR 4. Other(describe) 6-1-2018 5. MASONRY BEARING WALL (con't) h. Masonry finishes— interior- FAIR 1. Vapor barrier NONE 2. Furring and Plaster FAIR 3. Paneling FAIR 4. Paint Only FAIR 5. Other (describe) i. Cracks: TYPICAL CONTRACTING & EXPANDING CRACKING NOTED 1- Location - note beams, columns, other 2. Description: NOT WARRANTED TO JUSTIFY REPAIRS AT THIS TIME j. Spalling: NONE VISIBLE 1. Location - note beams, columns, other 2. Description N/A k. Rebar corrosion- check appropriate line: 1. None visible XXXX 2. Minor —patching will suffice 3. Significant — but patching will suffice 4. Significant — structural repairs required 1. Samples chipped out for examination in spall areas 1. NO XXXX 2. YES — describe color texture, aggregate, and general quality 6. FLOOR AND ROOF SYSTEM a. Roof: l . Describe (flat, slope, type roofing, type roof deck, conditions ROOF IS WATER TIGHT AT THIS TINE 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment and conditions fit support: FAIR 3. Note types of drains and scupper and condition of cooling towers, air conditioners: DRAINAGE TO PFRTMETER OF ROOF b. Floor system (s): 1. Describe (type of system framing, material, spans, condition) SLAB/ FAIR c. Inspection— note exposed areas available for inspection, and where it was found necessary to open ceilings, ctu. For inspection of typical framing members: ALL ACCESSIBLE AREAS WERE INSPECTED. 7. STEEL FRAMING SYSTEM a. Description NO STEEL FRAMING CBS b. Exposed Steel — describe condition of paint & degree of corrosion: SATISFACTORY AT THIS TIME c. Concrete or other fireproofing— note any cracking or spalling, and note where any covering was removed for inspection NONE d. Elevator sheave beams & connections and machine floor beams — note condition: N/A 6-1-2018 8. CONCRETE FRAMING SYSTEM a. Full description of structural system CBS STRUCTURE b. Cracking 1. Not Significant XXXX 2. Location and description ofinembers affected and type cracking c. General condition FAIR d. Rebar corrosion - check appropriate line: 1. Non visible XXX 2, Location and description of members affected and type cracking 3. Significant— but patching will suffice 4. Significant— structural repairs required (describe) e. Samples chipped out in spall areas: 1. No XXXX 2. Yes, describe color, texture, aggregate, general quality: 9. WINDOWS a. Type (Window, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted, fixed, other) ALUMINUM/ AWNING b. Anchorage — type & condition of fasteners and latches. SCREWED INTO WINDOW BUCKS c. Sealant —type of condition of perimeter sealant & at mullions: TYPICAL CHAULKING AT FRAMES AND GASKETING AT GLAZING d. Interior seals— type & condition at operable vents: GASKETING AT GLAZING 10. WOOD FRAMING a. Type— fully describe if mill construction, light construction, major spans, trusses, PARTITIONS FRAMED WITH TRUSSES DECKED WITH LUMBER / PLYWOOD / BOARDS NOTED MEMBERS IN FUNCTIONAL CONDITIONS AT THIS TIME b. Note metal fitting i.e., angles, plates, bolts, split pintles, other, and note condition: METAL FITTING IY FUCTIONAL CONDITIONS LIMri ED ACCESS c. Joints — note ifwell fitted and still closed: FAIR CONDITIONS d Drainage — note accumulations of moisture: FAIR ROOF DRAINS TO PERIMETER e. Ventilation —note any concealed spaces not ventilated: ATTIC TYPICALLY VENTED WITH PERIMETER SOFFIT VENTS f. Note any concealed spaces opened for inspection: NONE/ ALL AREAS AVAILABLE WERE ACCESSED 11. GENERAL ADDITIONAL COMMENTS: THIS REPORT DOES NOT REFLECT ANY POTENTIAL VIOLATIONS THAT MAY BE PRESENT ON THE BUILDING. THIS IS ONLY AN INSPECTION OF THE VISUAL CONDITIONS FOUND DURING OUR INSPECTION. Continued maintenance is suggested to maintain proper function. Inspection is made to what is readily accessible and visible only. AS A ROUTINE MATTER, AND IN ORDER TO AVOID POSSIBLE MUSUNDERSTANDING NOTHING IN THIS INSPECTION REPORT FORM ATTACHED MINIMUM INSPECTION GUIDELINES AND OUR NON-DESTRUCTIVE OBSERVATION SHOULD BE CONSTRUED DIRECTLY OR INDIRECTLY, AS A GUARANTEE OR WARRANTEE OF ANY PORTION OF THE STRUCTURE. TO THE BEST OF MY KNOWLEDGE AND ABILITY THIS REPORT REPRESENTS AN ACCURATE APPRAISAL OF THE PRESENT CONDITION OF THE STRUCTURE BASED UPON CAREFUL EVALUATION OF THE OBSERVED CONDITIONS TO THE EXTENT REASONABLY POSSIBLE. THIS REPORT DOES NOT REFLECT ANY POTENTIAL VIOLATIONS THAT MAY BE PRESENT ON THE BUILDING. THIS IS ONLY AN INSPECTION OF THE VISUAL CONDITIONS FOUND DURING OUR INSPECTION. IF A VIOLATION EXISTS THEN THIS REPORT IS INVALID. 6-1-2018 9 4WE\ G I '_\ E E I: S I\ S P E C WO ]a S "S�rving Floricla Co,3st to Coast•• 8 7 7- 8 9 4- 8 0 0 1 12SSS Biscayne Blvd- # 934 North Miami,, FL 33161 CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTYAND OUTDOOR LIGHTING OVERSPILLING SECTION 33-4.1 OF THE CODE OF MIAMI DADE COUNTY INSPECTION COMMENCED INSPECTION MADE BY: DATE: 6-1-2018 Florida Builders Engineers & Inspectors Gordon W Myers PE 36852 /CA 31260 INSPECTION COMPLETED 12555 Biscayne Blvd #934 DATE: 6-1-2018 North Miami, Florida 33181 Tel: (305) 895-8001/ Far: (305) 895-7001'_ Name of Title: LESTER EUGENE DONALDSON GRACE DONALDSON Street Address: 705 NE 92 ST MIAMI SHORES, FL 33138 Legal Description: 5 6 53 42 MIAMI SHORES SEC 3 PB 10-37 PARTS OF LOTS 22-23 BEG 25FTE OF SW COR LOT 22 E75FT NW135FT W57FT SE131.23FT TO POB BLK 63 LOT SIZE 66.000 X 130 OR 19740-2237 06 2001 1 COC 25316-0590 06 2006 5 Owner's Name: LESTER EUGENE DONALDSON GRACE DONALDSON Owner's Mailing Address: 705 NE 92 ST 2 MIAMI SHORES, FL 33138 Folio Number of Building: 11-3206-014-1561 Building Code Occupancy Classification: 0803 MULTIFAMILY 2-9 UNITS: MULTIFAMILY 3 OR MORE UNITS Present Use: 4 RESIDENTIAL UNITS General Description, Type of Construction, Size, Number of Stories, Features: CBS (2) STORY TOTAL ADJ. AREA 4,789 SQ FT ACCORDING TO P. REC The undersigned states the following: 1. I am a Florida registered professional engineer with an active license. 2. On June 1, 2018, at 8PM I measured the level of illumination in the parking lot(s) serving the above referenced building. 3. Maximum 4.2 foot candle per SF, Minimum 3.0 foot candle per SF, Minimum to Maximum ratio 1.2, foot candle, 3.6 average per SF. 2. The level of illumination provided in the parking lot(s) meet the minimum standards for the occupancy classification of the building as established in Section 8C-3 of the Code of Miami -Dade County. 3. The level of outdoor lighting overspill meets the limitations established in Section 33-4.1 of the Code of Miami Dade County. Gordon W. Myers PE 36852 Florida Builders, Engineers & Inspectors, Inc. A Professional Engineering Firm CA 31260 6-1-20 t' 10 ,���� FLaR.II72%, gi.%ILDElt S 4Wr� r rvr_rrss s. »sr � cz•oKs S darVi nit t-icl2a (C c�a st tea C<:�,nS t'" 8 7 7- S 9 4— S O O 1 125SS Biscayne Blvd- 4 934 North Miami, FL 33181 CERTIFICATION OF COMPLIANCE WITH PARKING LOT GUARDRAILS RE UIREMENTS IN CHAPTER SC OF, THE CODE OF MIAMI-DADE COUNTY INSPECTION COMMENCED INSPECTION MADE BY: DATE: 6-1-2018 Florida Builders Engineers & Inspectors Gordon W Myers PE 36852 /CA 31260 INSPECTION COMPLETED 12555 Biscayne Blvd #934 DATE: 6-1-2018 North Miami, Florida 33181 Tel: (305) 895-8001/ Far: (305) 895-70A' Name of Title: LESTER EUGENE DONALDSON GRACE DONALDSON Street Address: 705 NE 92 ST MIAMI SHORES, FL 33138 Legal Description: 5 6 53 42 MIAMI SHORES SEC 3 PB 10-37 PARTS OF LOTS 22-23 BEG 25FTE OF SW COR LOT 22 E75FT NW 135FT W57FT SE 131.23FT TO POB BLK 63 LOT SIZE 66.000 X 130 OR 19740-2237 06 2001 1 COC 25316-0590 06 2006 5 Owner's Name: LESTER EUGENE DONALDSON GRACE DONALDSON Owner's Mailing Address: 705 NE 92 ST 2 MIAMI SHORES, FL 33138 Folio Number of Building: 11-3206-014-1561 Building Code Occupancy Classification: 0803 MULTIFAMILY 2-9 UNITS: MULTIFAMILY 3 OR MORE UNITS Present Use: 4 RESIDENTIAL UNITS General Description, Type of Construction, Size, Number of Stories, Features: CBS (2) STORY TOTAL ADJ. AREA 4,789 SQ FT ACCORDING TO P. REC The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. On June 1, 2018 I inspected the parking lots servicing the above referenced building for compliance with Section 8C-6 and determined the following (check only one): The psi rkIna lot(s) is nal adiaeeal to arabut tine a canal. Inke or rattier hodti• of hater. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are protected by a guardrail that complies with Section 8C-6 ofthe Miami -Dade County Code. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are not protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. I have advised the property owner that he/she must obtain a permit for the installation of the guardrail and obtain all required inspection approvals to avoid enforcement action. Gordon W. Myers PE 36852 Florida Builders, Engineers & Inspectors, Inc. A Professional Engineering Firm CA 31260 6-1-2018