Loading...
RF-05-21-1121 uplift testDederal � Zl , j 1 b Phone: 954-784-2941 �1 E-Fax: 954-784-7875 adm.ngineering www.fed-eng.com www.fed-eng.com p& nesting, Inc. Dated: Thursday, September 9, 2021 David Bange Roofing 6900 SW 21 st Court Suite #13 Davie, Florida 33317 RE: TAS-106 Tile Uplift Test Proposed Roof: Oleksandr Roman Permit* RF05211121 225 NE 96th Street Miami Shores, Florda 33138 Order Number 21 R0730 In accordance with your authorization, Federal Engineering & Testing, Inc. has performed Tile Uplift Testing in compliance with Testing Application Standards TAS-106 and the Florida Building Code High Velocity Hurricane Zone on September 8, 2021 at the above referenced project. The purpose of our inspection was to determine the uplift capacity of the roof tiles for the residence at the above referenced project. The subject roof consisted of Flat Concrete Tile Foam Set. The pitch of the subject roof is 4/12. Our field engineer visited the site and conducted 65 uplift tests on the roof tiles. All tests were performed according to the Florida Building Code High Velocity Hurricane Zone and protocol TAS-106 using an Intercomp Scale Model CS200. The following is a summary of results: Field Test Results Test Number Test Location Field Uplift Pull Test Test Results 1 - 8 Corner See Attached Diagram 35 ± 5 Pounds Passed 9 - 39 Perimeter See Attached Diagram 35 ± 5 Pounds Passed 40 - 55 Field See Attached Diagram 35 ± 5 Pounds Passed 56 - 65 Hip/ Ride See Attached Diagram 35 ± 5 Pounds Passed All test results were found to be in compliance with TAS-106 and the Florida Building Code The test results are limited to the tested areas. If other roof areas exhibit different conditions, it should be brought to our attention for remedial work. This uplift test is not a roof top inspection. A final roof inspection must be conducted by the building official for approval. The test results presented reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing due to exposure to the elements. Federal Engineering & Testing, Inc. is an independent third party providing un-biased testing information and results and is not affiliated with our client nor do we have any financial interest in the project or determination of the test results. As mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. We appreciate the opportunity to be of service to you at this phase of your project. If you have any questions or comments, please give us a call. It has been a pleasure working with you and look forward to doing so again in the near future. Sincerely, JejW'Tanon; P.E. Federal Engineering & Testing, Inc. Florida Reg. No. 70946 Certificate of Authorization # 5471 Miami -Dade County Certification # 21-0201.02 -� - - 3370 NE Sth Avenue gakland Park Florida 3333A -- - CMEC ■MIAMIM • n Ct7UNTY 741 eSJ 146 44 3.1 �$ f< 4 -x �L4 5i 3�i a= 0.1 (w) = 0.1( 70 ') = 7.0 ' a= 0.4 (h)= 0.4( 20 ') = 8 ' Perimeter Dimensions = 4 ' Figure R301.2(7) Component & Cladding Pressure Zones Corner Area: 128 S.F. = 8 tests Perimeter Area: 976 S.F. = 31 tests Field Area: 1996 S.F. = 16 tests Ridge Caps: 204 = 10 tests Total Tests Performed: = 65 Aegineering ederal Molesting, Inc. V N *All dimensions are approximate* Test Location Sketch Federal Engineering & Testing Inc. 3370 NE 5th Avenue, Oakland Park, FL 33334 Client: David Bange Roofing Project: Proposed Roof: Oleksandr Roman Test: TAS-106 Tile Uplift Test Project Address: 225 NE 96th Street (Test location sketch is not to scale) Miami Shores, Florda 33138