Loading...
RF-03-19-654 UPLIFTek I [MGIMEER0G 4225 SW 71 Ave, Miami- FI 33155 Tel: 786-398-9179 Fax: 786-800-2627 a 1 roofiinsoectionCa)arnail. corn LAB CERTIFICATION #16-0510.15 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 07/26/2019 Roofing Contractor HEROES ROOFING Permit IZF-03-19-654 Job Address 10520 NE 6 AVE MIAMI SHORES Owner's Name ALEJANDRO M .MENENDEZ Type of Tile FLAT 13" Approximate Roof Height 12 feet Roof Pitch 4/12 Approximate Square Footage of Roof 27 ftz Date Tested 07/25/2019 Number of Tests 75 Contact Name RAUL Date Installed Type of Access to Roof LADDER Required Testing Force 35 Lbs Testing Equipment F.G.E.100 Phone # 786-489-9838 LOCATION # OF TEST PASS # OF TEST FAIL Corner 10 Tests 10 Pass Test Fail Perimeter 18 Tests 18 Pass Test Fail Field 27 Tests 27 Pass Test Fail Ridge 20 Tests 20 Pass Test Fail TOTAL 75 Tests 75 Pass 0 Test 0 Fail IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF AS5EMRLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS ("' ' _ WITI4 NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL DISASTERS. THIS REPORT IT IS NOT VALID FOR INSURANCE CLAIMS. YENAN T:.-LEY'VA PE 67416 -job Address 10520 NE 6 AVE MIAMI SHORES Permit Number tZF03-19-654 Roof Drawing