RF-11-18-3552 MITIGATION RETROFITRemberto Contreras PE 8306 Mills DR, Suite 369 Miami FL 33183 PI-1: 305-256-2416 AFFIDAVIT OF COMPLIANCE TO WALL CONNECTIONS HURRICANE, MITIGATION RETROFIT February 13.2019 Village of Miami Shores r Building Department 10050 NE 2" d Avenue Miami Shores FL 33138 RE: Roof to Wall Connection Contractor: HIGH & DRY ROOFING CONTRACTORS. INC 150 NW 108 ST Miami Shores. FL l'o Whom it may concern. We have inspected the roof' framing and roof framing anchors at the above referenced property as required by adopted by the Florida Building Commission by Rule 913-3.047 F.A.C. We, hereby certify that the roof framing has wood trusses that are spaced at 24" in O.C. and they are in good condition. Each truss is anchored to the concrete tie beam with metal straps that wraps over the wood joist with one '''A" TAPCON 2 '/" on each side of the strap. For this roof frame the number of nails per strap complies with the requirements to resist the uplift load. The above is in accordance as specified in the FBC 2017 edition Section 908.8 for Existing Building. This report is based on limited visual review of existing structural components. Please do not hesitate to contact our office i f you have any questions. Sincerely. I 11111���i C 522 � Raheito an - �r s 11. E * =_ P.GI . U 5225CA J ttr W~ �.,��5/ O N Ali,,.