Loading...
EL-19-1882Permittti0.: EL-08-19-1892 Miami Shores Village n Permit Type: Elecraeal - ResiderAW 10050 NE 2 AveNMiami Shores FL 33138 Work Cir ssiftca ort. SOtar 9 305-795-2204 Permit Stotasr Approved Issue .09/,26/201-9Expiration: 03/24/2020 Location Address Parcel Number 570 NW 112TH ST, Miami Shores, FL 33168 1121360210620 Contacts DAVID SMITHERMAN Owner TITAN SOLAR POWER FL INC Contractor 570112 ST, MIAMI SHORES, FL 33168 KENNETH WILLIAMS 12221 N US HWY 301, THONOTOSASSA, FL 33592 Business: 3057760650 jjeune@titansolarpower.com Description: ROOFTOP SOLAR Valuation: $ 31,200.00 Inspection Requests: »�62-4949 Total Sq Feet: 0.00 Fees Amount Payments Date Paid Amt Paid Application Fee - Other $50.00 Total Fees $50.00 Credit Card 08/15/2019 $50.00 Total: $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regglating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Owner / Applicant / Contractor / Agent Date September 26, 2019 Page 2 of 2 rr l Miami Shores Village I ED ` �iQ,r►ct � ��� I ��6��� U Building Department UG 1 5 19 �' tip g p 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 co7(� Tel: (305) 795-2204 Fax: (305) 756-8972 BY INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 11 BUILDING Master Permit No. PE IT PLICAT Sub Permit No. QBUILDING 0 ELECTRIC ❑ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 570 NW 112th St, Miami, FL 33168, City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11 -2136-021 -0620 Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): David Smitherman Phone#: 305-970-5376 Address:570 NW 112 ST City: Miami State: FL Zip: 33168 Tenant/Lessee Name: Phone#: Email: dsmlth3rm4n@gmail.com CONTRACTOR: Company Name: Titan Solar Power FL Inc Phone#: 813-982-9001 Address: 525 W Baseline Rd City: Mesa State: AZ Zip: 85210 Qualifier Name: Kenneth Williams Phone#: 813-982-9001 State Certification or Registration #: EC13008093 Certificate of Competency #: DESIGNER: Architect/Engineer: Add Value of Work for this Permit: $ 26,000 one#: City: State: Zip: Square/Linear Footage of Work: Type of. Work: ❑ Addition N Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Rooftop Solar Specify color of color thru tile: Submittal Fee $ 1 Permit Fee $"�}A� ` CCF $ \5. WO CO/CC $ Scanning Fee $ 1• �" — Radon Fee $ " I . to DBPR $ II). W5 Notary $ Technology Fee $ �1 Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ lU TOTAL FEE NOW DUE $ q M • 3 0 (Revised02/24/2014) 3g.-3s Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature 61TIN.1a 1079wa►rI The foregoing instrument was acknowledged before me this day of 1-1UV C 20 (G by `no�vlc� li�P�cl�A who is personally known to me or who has produced yL Ui _ as and who did take an oath. NOTARY PUBLIC: Signatu CONTRACTOR The foregoing instrument was acknowledged before me this day of 7CAU 20t0 by wl �� W`A\g S , who is personally known to me or who has produced �) L as identification and who did take an oath. NOTARY PUBLIC: Sign: Sign: C RI DEE PORASIK Print: G _q�BZ Prin f"Jt"�$� ) ?'�� ��% f Florida _• *? Commission # GG 310262 Seal: Seal: �,� My Commission Expires March 11, 2023 ��Y1pY PUb CHRIS ABRAHAM GONZALEZ �•/���'•°��"'� �fo Notary Public -State of Florida Commission# GG 310255 0F�Marco 11, 2023 k APPROVED BY IkO6 Plans Examiner a3 Zoning Structural Review Clerk (Revised02/24/2014) PROJECT DESCRIPTION LOCATION MAP SCALE: NONE IRRADIANCE MAP SCALE: NONE 3D RENDERING SCALE: NONE DATE z 67 Z cn G 0 M m 0 X 1zw ;amz 0G) m r m n n K m m irmaNi ROOF OBSTRUCTIONS I I I I I I �- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I /I / I A2.4 A1.2 A2.3 � A1.3 I L A1.4 I A2.2 ' A1.5 A2.1 I ; A1.9 A1.6 A1.7 A1.8 �I P GONZ4,C ARRAY LAY OUT,�4k,� ``� '�►GENSF . 0% SCALE: 3/16" = 1'-0" 4:7:•' ;A DESIGNER CONTACT INFORMATION ENGINEERING STAMP COMPANY CONTACT INFO ENGIPARTNERS, LLC Y •••. P� TITAN SOLAR POWER FL, INC. C.A. 32661 I// '• 12221 N US HIGHWAY 301 i 111 �k. 330 SW 27 AVE STE 508 MIAMI, FL 33135 / / •, STATE OF •• �IOR Q� \ THONOTASASSA, FL 33592 \ RGONZALEZ(�ENGIPARTNERS.COM / ►Dp!.. �_l1 '•. ol ��� S�o • • • • • •�� � (813)982 -9001 786 - 393 - 4740 1`EC 13008093 r9im _ ARRAY -A TILT=16.46° AZIMUTH= 88° (E) C 7tty I_ NUG 1 5�,,f, i 1l1aiIC R:J I tELECITryi C.".L RCr_—.ViE V, Y OARRAY-B B2.6 TILT=16.46° _ AZIMUTH= 88° (E) B2� 62.8 COMPAhYLOGO °U TITAN S O L A R P O W E R CUSTOMER DAVID SMITHERMAN PROJECT PV GRID -TIED 5.1 KW DC 17.6 KW AC STRING INVERTER SYSTEM ADDRESS 57D NW 112TH ST, MIAMI, FL 33168, USA PARCEL NUMBER FOLIO: 11-2136-021-0620 SHEET NAME PROJECTIO TSP25939 INSTALL DETAILS SHINGLE INSTALLATION OF GRID -TIED PHOTOVOLTAIC STRING INVERTER SYSTEM ON SHINGLE ROOF OF EXISTING FAMILY RESIDENCE. SYSTEM CAPACITY: 5.1 KW DC / 7.6 KW AC PV PANELS: (17) SLA-M 300 30OW 60 CELLS OPTIMIZERS: (17) OPTIMIZERS P320 INVERTER: (1) SE760OA-US 240V INVERTER FROM STORE EDGE RACKING SYSTEM: IRONRIDGE XR RAIL FAMILY MODEL XR100 ARRAY -A: 13 PANELS ON PORTRAIT SETUP FACING EAST, RAILS NORTH TO SOUTH ON PITCHED ROOF ARRAY-B: 4 PANELS ON PORTRAIT SETUP FACING EAST, RAILS NORTH TO SOUTH ON PITCHED ROOF GENERAL NOW • • PER FL. STATUTE 377.78?(RE\MSED 7/1(W61.1 FAEL A. GORZALEZ SOTO, P.E. 83104 AN E►1610116 2 LICENSG)&PLJ28UANT T"MVR 471, CERTIFY THAT TV,p ECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESI D AND APPROVED IN 1HE STANDARDS CONTAINE"IINOTHE MOST RECENT VERSt)•dFP=HE FLORIDA BUILDING C • • • • • • • APPLICABLE CODES:2"GFEMRIDA BUILCO40000DE 6TIr,•ADC:3-10 MINIMUM DESIGN LO41;? EQtBUILDI9I�.jI'b QTHER STRUCTURES, NEC 2014 ELECTRICAL CODE • • • • • • • •••••• ALL WIND DESIGN 41TEISIA IND PAPAMETF•RS ARE FOg HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERIYG Gl-- A 7° T- A �iI"AIUM 27• (2/12 TO A MA:IMUW%12 PITH ROOF IN SCINEDULE.*4LL RESIDENTIAL ROOFS SHALL N40T EXCEjD 3%% MEAN R(VI` MrT. ROOF SEALANTS SHALL CONFORM TO A®TM 6920 AND ASTM 6511, AND owes IS RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA BUILDING CODE OR LOCAL GOVERNING CODE. ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (NEC) 2014, LOCAL STATE CODES, AND OTHER APPLICABLE LOCAL CODES. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING CONDUCTORS OF THE PHOTOVOLTAIC POWER SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING. CONNECTORS TO BE TORQUED PER DEVICE LISTING, OR MANUFACTURERS RECOMMENDATIONS. NON -CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING. REQUIRED SAFETY SIGNS AND LABELS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE, OR OTHER MECHANICAL MEANS, LABELS SHALL COMPLY WITH ARTICLE 690 VI OF THE NEC 2014 OR OTHER APPLICABLE STATE AND LOCAL CODES. SEE LABELS AND MARKING PAGE FOR MORE INFORMATION. SHEET SUMMARY C-1 COVER SHEET E-1 SINGLE LINE E-2 LABELS S-1 STRUCTURAL PLAN S-2 RACKING PLAN D-1 DATA SHEET D-2 DATA SHEET D-3 DATA SHEET PROJECT INFORMATION PROJECT LATITUDE 25.8772D6 MIN AMBIENT TEMP 5° C PROJECT LONGITUDE -80.207653 MAX AMBIENT TEMP 34- C UTILITY NAME FPL NAND EXPOSURE C AHJ I MIAMI SHORES MAX NAND SPEED 168 mp COVER SHEET DESIGNED BY I SHEET TITLE /•� ENG. RAFAEL A. GONZALEZ SOTO, PE C-1 DATE SHEETS 1 OF 8 07/01/2019 WIRE SIZES, QUANTITY & TYPE RACEWAY SIZE, TYPE, LOCATION & INFO. WIRE AMPACITY CALCULATIONS ADDITIONAL INFORMATION WIRE TAG CONDUCTOR OTY. SIZE & TYPE DCA (BEFORE JB) (6) #10 AWG PV WIRE DC.2 (AFTER JB) VvlR (6) #10 AWG PV WIRE ACA(FROM INVERTER TO (#6 AWG TV SERVICE) PV MODULE MANUFACTURER: SILFAB SOLAR MODEL: SLA-M300 30OW 60 CELLS QUANTITY ................................................. (17) POWER AT STC........................................ 300" POWER AT PTC........................................ 227" V-OC (OPEN -CIRCUIT VOLTAGE)........... 39.85 V-MP (MAX -POWER VOLTAGE) ............. 32.8V -SC (SHORT-CIRCUIT CURRENT).......... 9.71A I -MP (MAX -POWER CURRENT) ............... 9.16A MNFR V.00 TEMP COEFFICIENT: -0.3001 PV OPTIMIZER MANUFACTURER:SOLAREDGE MODEL. P320 QUANTITY........................................17 MAXIMUM 1-SC INPUT....................11A MAXIMUM V-OC INPUT...................48V MAXIMUM POWER PER STRING ... 570OW INVERTER SOLAREDGE_TECHNOLOGIES SE-7600A-US(240V) MODEL: SE-760OA-US MAX.OUTPUT CURRENT ......................... 32A MINIMUM OCPD.......................................40A MAX NUMBER OF STRINGS .................... 2 NUMBER OF MPPT'S................................1 MAXIMUM INPUT VOLTAGE .................... 480V TRANSFORMERLESS (Y/N)..................... YES OPERATING CURRENT ............................15A OPERATING VOLTAGE.............................380V MAXIMUM SYSTEM VOLTAGE.................500V SHORT CIRCUIT CURRENT .....................12.8A NEUTRAL GROUND RACEWAY RACEWAY RACEWAY HEIGHT OUTPUT 125% OF MIN WIRE DE -RATED CALCULATION QTY. SIZE & TYPE QTY. SIZE & TYPE SIZE & TYPE LOCATION ABOVE ROOF I CURRENT OUTPUT OCPD WIRE AMBIENT # OF FINAL CURRRENT RATING TEMP COND. AMPACITY (1) #6 AWG (1) #8 AWG BARE COPPER NOT APPLICABLE UNDER ARRAY 1/2" TO 3-1/2" 15A 18.8A 20A 40A X 0.76 X 1 = 30.4 A THWN-2 (1) #8 AWG THWN-2 3/4" EMT CONDUIT ABOVE ROOF 1/2" TO 3-1/2" 15A 18.8A 20A 40A X 0.76 X 0.8 = 24.3 A (1) #8 AWG THWN-2 3/4" EMT CONDUIT EXTERIOR WALL "N/A" 32A 40A 40A 55A X 0.76 X 1 = 41.8 A SINGLE LINE DIAGRAM SCALE: NONE DATE GONZ4,(F �\ \,\CENSF' `rO i <cQ' A .. = 4r No. 83104 G s DESIGNER CONTACT INFORMATION -- ENGINEER I STAMP — COMPANY CONTACT INFO ENGIPARTNERS, LLC � � ` I�/� ( UI /y •� TITAN SOLAR POWER FL, INC. C.A. 32661 Oy •. STATE ®F 12221 N US HIGHWAY 301 330 SW 27 AVE STE 508 MIAMI, FL 33135 •• �(w�' • . P _ •' Ft THONOTASASSA, FL 33592 • R1>� \\ RGONZALEZ@ENGIPARTNERS.COM "'-S' (+�� . GY� /,/// \\ (813) 982 -9001 786-393-4740 /....... ,®NAl- \\� XEC13008093 17 DIST. VOLTAGE VOLTAGE CONDUIT 1 DROP % FILL 10 FT. I 350V 0.11 % 6.4% 20 FT. 350V 0.21 % 8.1 % 5 FT. 240V 0.1 % 7.7% NEW 200A LINE SIDE • SOLAR READY SIEMENS • " • • • • MC404OS1200SC • • • • • • • • 240V/120V 200A BUS BAR • • • • • • • • • OR EQUIVALENT • • • • • • • • • • •••••• •••• ••••• INVERTER TOTAL OUTPUT: 32A • • • • • SAFETY RATING (125°�): 40A • • • • •• • • • • • • • TOTAL PV SYSTEM OCPD: 40A • • • • • • • • RACKING ROOF MOUNT SYSTEM SHALL.BE INSTALLED FOLLOWING • MAIN BREAKER RATING: 200A MANUFACTURERS INSTRUC-MON MANUAL, LUE)ING AL! • • • • • MAIN PANEL RATING: 200A GROUNDING WEEB CLIPS, GROUND WJGS, AN 0.11,1C2 RAATTL ?4ICE KIT§ 120 % BACKFEED RATING: 40A FOR ELECTRICAL CONTINUITY • • • • • • • • PV MODULES SLAM 300 FROM SILFAB SOLAR 60 CELL 1 AUTO -TRANSFORMER 240/120 VAC, 5KW, 60 HZ P:300W, VMP: 32.8V, VOC: 39.85V, IMP: 9.16A, ISC: 9.71A 2 #10 PV WIRE 2 1 #8 BARE WIRE GROUND 11 AC LOAD CENTER RATED SPACE FOR 2 BREAKERS 3/4" EMT CONDUIT 3 NEMA3R JUNCTION BOX 12 1 - LG CHEM RESU10 BATTERY 9.7 KWH 4 #10 THWN-2 4 1 #10 THWN-2 GROUND 13 SINGLE TWISTED PAIR BELDEN 3106A OR EQUIV. 3/4" EMT CONDUIT SE760OA-US 240V INVERTER FROM SOLAR EDGE 1 #14 TWHN-2 GROUND- i 5 POWER: 7.6 KW, [MAX: 40A EFF @240V: 99% 14 2-6RTWISTEDPAIR CTLEADS ( WITH INTEGRATED RAPID SHUTDOWN MECHANICAL DC 2P SWITCH 3#14AV GTHWN-2 3/4" EMT CONDUIT i 6 2 #6 L1,L2 THWN-2 1 #8 TWHN-2 GROUND 15 CONDO 1 #6 THWN-2 NEUTRAL 3/4" EMT CONDUIT 3/4' EMT T 7 PV SYSTEM DISCONNECT RATED FOR 60A AIC RATING 100KA 16 VOLTAGE SENSOR BREAKER 2P-15A 8 BACKFEED PV BREAKER 2P-40A 17 SOLAREDGE METER ENCLOSURE SE-WNC-3D-240-MB AIC 10kA 9 SOLAR READY SIEMENS MC404OS1200SC 200A RATED WITH 2O0A MAIN BREAKER AIC 10KA OR EQUIVALENT COMPANY LOGO (U) TITAN 5 0 t. A R P O W E R CUSTOMER DAVID SMITHERMAN PROJECT PV GRID -TIED 5.1 KW DC 17.6 KW AC STRING INVERTER SYSTEM ADDRESS 570 NW 112TH ST, MIAMI, FL 33168. USA PARCEL NUMBER FOLIO: 11-2136-021-0620 SHEET NAME SINGLE LINE PROJECTID DESIGNED BY sntm 111Lt TSP25939 ENG. RAFAEL A GONZALEZ SOTO, PE E-1 INSTALL DETAILS DATE I SHEETS SHINGLE I07/242019 2 OF 8 Combiner Box / Circuits / Conduit Combiner Box / Enclosures / EMT Enclosures ® WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17 (E) I Part No. 596-00497 ® WARNING l ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED EMT / Conduit Raceways *(Reflective Material Required) NEC 690.35 (E) I Part No. 596-00588 NEC 690.311 Part No. 558-00206 PV SAFETY LABELS SCALE: 10"=V-00" ® WARNING TURN OFF PHOTVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27 (C) & OSHA 1910.145 (f)(7) Part No. 596-00499 0 Inverter WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 69U.5 (C) I Part No. 596-00498 PHOTOVOLTAIC ADISCONNECT • • 32A • • • • 240V \P ���%�� 0239 GONZq i \ / \P� �• �`GENS�.•• S � 4 O' 4T • .G h ._ —A nA LG CHEM RESU9.7 0 AC Disconnect / Breaker / Points of Connection =01110119"-w IFC 605.11.1, IFC 605.11.1.4, NEC 690.15, NEC 690.14(C)(2), NEC 690.13 (B) I Part No. 596-00237 ® WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17 (E) I Part No. 558-00497 0 Breaker Panel / Pull Boxes WARNING I ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.5 (C) I Part No. 558-00498 NEC 690.521 Part No. 558-00252 NEC 690.54 1 Part No. 596-00239 WARNING TURN OFF PHOTVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27 (C) & OSHA 1910.145 (f)(7) Part No. 558-00499 MCNIMEL 240V ' NEC 690.33 (E)(2) I Part No. 558-00244 NEC 690.54 I Part No. 558-00239 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED NEC 705.15(D)(4) &NEC 690.64 Part No. 558-00495 DATE DESIGNER CONTACT INFORMATION ENGINEERING STAMP COMPANY CONTACT INFO ENGIPARTNERS, LLC C.A. 32661 -y 330 SW 27 AVE STE 508 j MIAMI, FL 33135 IOtt RGONZALEZ@ENGIPARTNERS.COM // 786 - 393 - 4740 ,�/�A/�f ~I/l£(/Vl�//pJ(�M/ STATE OF l N,w.`OR`O,r' �G. f'� ' -• TITAN SOLAR POWER FL, INC. 1 12221 N US HIGHWAY 301 k/ THONOTASASSA, FL 33592 `��\ (813)982 -9001 #EC13008093 lII... III COMPANYLOGO TITAN S 0 L A R P 0 W E R Main Service Disconnect A WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.17 (E) I Part No. 558-00497 WARNING TURN OFF PHOTVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 690.5(C) I Part No. 558-00499 A WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION . . .... ...... • • • • • • • • • • • • • • • • • • ...... .... ..... .... .. . ...... CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED NEC 690.15 & NEC 690.13(B) I Part No. 558-00613 Main Service Disconnect / Utility Meter NEC 690.17 (E) I Part No. 558-00497 WARNING DUAL POWER SOURCE AC Disconnect PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED NEC 705.12(D)(4) & NEC 690.64 1 Part No. 558-00495 ®WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(2)(C) I Part No. 558-00589 CUSTOMER DAVID SMITHERMAN PROJECT PV GRID -TIED 5.1 KW DC 17.6 KIN AC STRING INVERTER SYSTEM ADDRESS 570 NW 112TH ST, MIAMI, FL 33168, USA PARCEL NUMBER FOLIO: 11-213"21-0620 LABELS PROJECT IO DESIGNED BY SHEET TITLE TSP25939 ENG. RAFAEL A. GONZALEZ SOTO, PE INSTALL DETAILS DATE SHEETS SHINGLE 07/24/2019 E-2 30F8 SCALE: 3/16"= V-00" m cD v (n cD cD P G014Zg4 'VICE SF •�sOi/ A. C No. 83104 DATE DESIGNER CONTACT INFORMATION ENGINEERING STAMP COMPANY CONTACT INFO ENGIPARTNERS, LLC C.A. 32661 330 SW 27 AVE STE 508 MIAMi, FL 3135 FL 3 RGONZALEZ@ENGIPARTNERS.COM 786-393-4740 -/ J,l^�uy// / 1 • . • F� O RSTATE � P • • O F ��vS1 • • • • ... • ' • , TONAL .• � =1TAN SOLAR POWER FL. INC. ` 12221 N US HIGHWAY 301 4\� THONOTASASSA, FL 33592 � (813) 982 -9001 #EC13008093 2"x4" WOOD TRUSS SYSTEM TRUSS SEPARATION 24" COMPANYLOGO TU TITAN 5 0 L A R P 0 W E R ARRAY -A EACH ANCHOR TO MATCH TRUSS CENTER r f- 41 O"_a CUSTOMER DAVID SMITHERMAN PROJECT PV GRID -TIED 5.1 KW DC 17.6 KW AC STRING INVERTER SYSTEM ADDRESS 570 NW 112TH ST. MIAMI, FL 33168, USA PARCEL NUMBER FOLIO' 11-2136421-0620 ROOF AREA EXISTING SHIINGLE ROOF TOTAL ROOF AREA: 2,190.29 sq.-ft TOTAL PHOTOVOLTAIC AREA: 298.69 sq.-ft PERIMETER WIDTH: 4.0-ft PRESSURE ZONE: 1 & 2 MEAN ROOF HEIGHT: 12.2 -ft ROOF SLOPE: 4/12 -ft TOTAL MODULES: 17 TOTAL ROOF MOUNTS: 30 ZONE 1 ❑ -33.78psf ZONE 2 -58.81 psf ZONE 3 -58'8*?psf SHEET NAME STRUCTURAL PLAN PROJECTID DESIGNED BY SHEET TITLE TSP25939 ENG. RAFAEL A. GONZALEZ SOTO, PE S-1 INSTALL DETAILS DATE SHEETS SHINGLE 07/01/2019 4 OF 8 Slotted L-Foot Our Slotted L-feet are engineered for most roof moon6n9 applications. Vertical slots allow for easily dropping in rails with attached hardware and provide adjunahllity to xc m for .of kregul.nties. ,-«.. Property value Material 600 11611 Aluminum .j Finish Mill & Black Height 3' Width 2" Depth 2' .�. _ Lerx3lh of Vertical Slot mii0Weight 1.125' -_ 0.22 Lbs Hardware 3/9-SS XR100 Rail XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans. Property Value Material 6000 Series Aluminum Finish Clear & Black Anodized Beam Height 2.44" Weight / Linear Foot 0.68 Lbs Total Cross -Sectional Area 0.582 In Section Modulus (X-axis) 0.297 Ina Moment of Inertia (X-axis) 0.390 In Moment of Inertia (Y-axis) 0.085 In Torsional Constant 0.214 Ina Polar Moment of Inertia 0.126 In Dace approved 8o16 to-i'rx It substrates including .most Kynar^ccated metals - outstanding oorwirg and adhes;�e qualities OEScan"r Nt �E - _ - a. ar or^=ar K•a rno„er„«r ;x>:=s as or a� �,,,� zs, m a•snr.�ka ,as 2+er=.n o� wee AVPLyuetF srnwoAaos M E ...z-o ce 6a4r,rn -w *susext. �. , ... 4 s - ..5fe�ar Soar - - Oa 'hC. 9[CM@fv5:P!or :cP3.Yur,a rA 9t£' ons fromroun?Ar r +Pa .ormaz<hi :5tb- max a . r,w..:-nrt nr",n nor be rR.arm Sax sop' aW M M,ertrp a 'iA 9t' form t av ^k M Ic.! ow , mast a, mos. _ .�d,r.":aot.Y wxnxs»na ro,T,'mammt M+,. �.woa. ,. INSTALLATION P-G-L, ws _ o-.ea cvr<..f, raa.,«msor v>e t4mf•DaM Gmry Cm,iaxatNnr: care o� iek atl"<er�t .reaeE Sees`-?an>r'anr�cPaz+'weE;s', m... rn9a;:.r F'tiY'.nnir,y..a.aubua�en: rvruq. of W lane :. cwx- o+v e, syFKMY•ary ,qm to a'H ^sxo ntltl'ssr«- taxre.<,vtvroora.r ymateeswSh rw. akabotc. �,"erer....r DATE Mid Clamp IronRidge Mid Clamps secure PV modules to the rail when there are multiple modules in a row. Property Value Material 5000 Series Aluminum Finish Mill & Black ( Spacing between Modules 1/4" Width 1" Depth 1.5" Weight 0.05 Lbs Hardware 1/4"-20 SS Nut and Bolt End Clamp IronRidge End Clamps secure PV modules to XR Rails using the top slot, independent upon the module's mounting holes. Property Value Material 5000 & 6000 Series Aluminum Finish Mill & Black Height Varies depending on Module Width 1.5" Depth 1.5" Weight 0.05 Lbs Hardware 1/4"-20 SS Nut and Bolt ATTACHMENT DIAGRAM 2 ROWS OF RAILS PER MODULE C�(P 1/4" SS 18-8 BOLT 1/4" SS SERRATED FLANGE NUT ALLOWABLE LOAD: 6,010 IDS. DISTRIBUTED LOAD: 364.8 Ibs SOLAR MODULE: 17.57 sq-ft MAX- RATED WIND LOAD: 78.00 psf WIND LOAD APPLIED:58.81 psf WIND LOAD APPLIED PER PANEL: 1,033.29 psf MAX LOAD PER PANEL: 1,370.46 Ibs - IRONRIDGE RAIL (XR-100 VERSION) ALLOWABLE LOAD OVER 64": 140 plf _ DISTRIBUTED LOAD OVER 64": 97.34 pif 6 9 O L E ALUMINUM L-FOOT ALLOWABLE LOAD: 707 Ibs. MAX. DISTRIBUTED LOAD: 585.53 Ibs7A NOTE: SEAL BASE MOUNT TO EXISTING ROOF UNDERLAYMENT WITH ROOF SEALANT AND MEMBRANE TOP VIEW DESIGNER CONTACT INFORMATION ENGIPARTNERS, LLC C.A. 32661 q 330 SW 27 AVE STE 508 / I / I MIAMI, FL 33135 / RGONZALEZ@ENGI PARTNERS.COM 786 - 393 - 4740 No. 83104 - ENGINEERIIe STAMP STATE OF �� '•.FLOR10pL.•'• S1 o:_ COMPANY CONTACT INFO 4 .TITAN SOLAR POWER FL, INC. /4 12221 N US HIGHWAY 301 THONOTASASSA, FL 33592 \\ \ (813) 982 -9001 #EC13008093 NGC ALUMINUM END CLAMP ALLOWABLE LOAD: 529 Ibs DISTRIBUTE LOAD: 363.8 Ibs <J �2 2X4 RAFTERS 24" O.C. SLOPE: 16.46 ASPHALT SHINGLES 5/16" SS LAG BOLT 5/16" SS FENDER WASHER ALLOWABLE LOAD: 798 lbs. MAX. DISTRIBUTED LOAD: 585.53 Ibs. All - SOLAR ROOF HOOK TITLE: MICROFLASHING PN: 17667SS SIZE MATERIAL: a04s5 REV COMPANY LOGO O,D TITAN 5 0 L A R P O W E R ARRAY WIND LOAD CALCULATIONS SOLAR PANEL 17 Total Area (SF) 298.69 Wind Load (PSF) -58.81 Total Wind Load (Ibs.) .17,565.95 Total Roof Mounts (#) Tension Force per Mount (tbs.) -585.53 LAG BOLT PULL OUT CALCULATIONS Spruce, Pine, I Per inch Thread Depth 266lbs SS Lag Bolt 5/16" x 4" I Min. Thread Depth 0'-3" Wood Strength x Thread Depth = Pull Out Strength 266 Ibs. x 3 in = 798 Ibs. Allows a Pull Out Strength per Lag Bolt 798 Ibs. Max. P tri Strength Required per tag Bell 585.53 La o Pull Oul Strength Safety Factor 1.36 ki20 U JWFOLUSH MOUNT SYSTEM SPAN TABLE (inches) RTRAIT INSTALLATION (MAXIMUM MODULE LENGTH 67.5") EXPOSURE B WIND SPEED (mph) ROOF SLOPE (degs.) GROUND SNOW: 0 psf ZONE 1 ZONE 2 ZONE 3 5 88 66 10 92 67 55 15 91 67 54 20 90 67 54 170 25 88 66 54 30 81 77 77 35 81 76 76 40 81 1 76 76 45 80 1 75 75 • • • • ••••• BOUT THIS L: •• .taelabue4 an �ItC WNLoa4r rorEMowo wloov.. oaaNn .rip. w.p •• WIND PRESSURE CALCULAT"S .l rAwa.Ne nscE ov» ^ws rAmv.P.<. ws1. Is. • DESIGN • • xiaxt be•, xKorpom a N.y • >. • • • FOR SOLAR MODULES INSTALLED ON ROOF • k« INn 60Ixt. BC VERSION 2017 DISK CATEGORY • • • • • • IEAN ROOF HEIGHT (n) 722 E �POSURI•CATEGORY • C ••••• ENGTH (a) 59.3 • • 4Rrlb•9.0•ti7 • • •'.e46 • le • • • ADTH(8) 352 RO��O*TYPE• a �IPPL� ARAPET HEIGHT (a) 0 � LTIMA%%ND SPEED e e 15�m�n • • • : • IODULE LENGTH (In) 64.96 4NOMN& WIN) SPEED 068-1, • IODULE WIDTH lin 38.97 * • : 5 • • OF MODULES IN ROW 7 • • e er• •Kn • : • e FFECTIVE WIND AREA (ft) 24.28 «z • • 0.85 • } • • • • • • • e • • • • VELOCITY PRESSURE (q) - 0025E KZKnK^Vr VELOCITY PRESSURE (ASO) 33.9 PRESSURE COEFFICIENT WIDTH 4.(r PRESSURE COEFFICIENT ZONE 1 0.5 .0.9 ZONE 0.5 -1.7 ZONE 0.5 .1.7 PRESSURE COEFFICIENT (H-) 0.18 ROOFZONE DOWN UP 2127 -77F-psi 3 212 SB.et W Uni-Rac Specs. Lag pull-out (withdrawal) capacities (Ibs) ASCE v 4Pre. . Lag Screw Installation Guidelines in typical roof lumber (ASD) =ro=aaozse�a.e sew 1. Determine location for the Mount on roof by drilling through the center of buss from bottom with STAINLESS STEEL Lag screw specifications 5/32" drill bit. a�.vN m.n 2. Mark mounting holes for Mount on Specific 5/5" Shaft, car=.oasrwaxl.n.r undedayment Mounting holes should be centered tit g-vity per inch thread depth _ ",na w•w 1-:7- r 1. n.o.,awna m on a trusses. «wam.. w^^•w•^^-n^p+�a,c 3. Drill 15/64"pilot hole. •..n...aw w.n. .".a uaw enn 4. Apply sealant to bottom of Mount. Douglas Fir, Larch 0.50 5. Place Mount over roof undedayment with holes Douglas Fir, South 0.46 in roof. 6. Apply sealant to bottom of Mount, apply sealant Engelman Spruce, ole Pine 0.46 Low. to lag screws and fasten Mount securely to er higher) (MSR 1650 f &high) lv b.w can trusses. ,n"rwetuc ryY«a an uwYy 7. Apply additional sealant to top assembly to be Hem, Fir, Redwood (close groin) 0.43 sure all penetrations are sealed. Hem, Fir (North) 0.46 Notes: (1) Thread must be embedded in the side grain of a Trusses or other structural 0.55 member integral with the building structure. Southern Pine (2) Lag Bolls must be located in the middle third of the structural member. (3) These values are not valid for wet services. Spruce, Pine, Fir 0.42 (4) This table does not include shear capacities. If necessary, contact a local engineer to specify lag boh size with regard to shear forces. Spruce, Pine, Fir (5) Install lag bolts with head ad washer flush to surface (no gap). Do nor over -torque. (E of 2 million psi and higher (6) Withdrawal design values for lag screw connections shall be multiplied by applicable grades of MSR and MEL) 0.50 adjustment factors if necessary. See table 10.3.1 in the American Wood Council NDS for Wootl Construction. Sources: American Wood Council, NDS 2005, Table 1 11.3A. 266 235 235 212 235 a! to 307 N a L N 205 � f 266 CUSTOMER DAVID SMITHERMAN SHEET NAME RACKING P LA N PROJECT PV GRID -TIED 5.1 KW DC 17.6 KW AC STRING INVERTER SYSTEM ADDRESS 570 NW 112TH ST, MIAMI, FL PROJECT ID DESIGNED BY SHEE 33168, USA TSP25939 ENG. RAFAEL A. GONZALEZ SOTO, PE PARCEL NUMBER FOLIO' 11-2136-021-0620 INSTALL DETAILS DATE SHEE \ SHINGLE 07/01/2019 TITLE S-2 50F8 e�. s,0L A R k- 1 ";R MOIIIIIIIIIIII om 100% MAXIMUM POWER DENSITY Silfab's SLA-M 300 ultra -high -efficiency modules are optimized for both Residential and Commercial projects where maximum power density is preferred. 100% NORTH AMERICAN QUALITY MATTERS Silfab's fully -automated manufacturing facility ensures precision engineering is applied at every stage. Superior reliability and performance combine to produce one of the highest quality modules with the lowest defect rate in the industry. NORTH AMERICAN CUSTOMIZED SERVICE Silfab's 100% North American based team leverages just -in -time manufacturing to deliver unparalleled service, on -time delivery and flexible project solutions. Electrical Specifications Test Conditions STC _ NCC Module Power (Pmax) WID 300 227 — — — Maximum power voltage (Vpmax) V 32.8 29.5 Maximum power current (Ipmax) A 9.1 7.69 _. P—__ ---.- _ Open circuit voltage (Voc) V 39.8S 36.9 Short circuit current(Isc) A 9.71 7.96 Module efficiency % 18.4 17.3 Maximum system voltage (VDC) V 1000 Series fuse •atitT A 20 Power Tolerance Wp -0/+5 Measurement _onditicns: STC t00G Wlm2 • AM 1.5 • Tempera:u•e 25 •C • NOCT 600 W/m2AM 1.5 - Measurement uncertainty s 3% .,,wn vmulater calibration reference modules f•om Fraunhofer lnsmute. n ctrical char tensti mayvary by 25%and pnwer by Temperature Coefficient isc %/K 0.03 Temperature Coefficient Voc %/K -0.30 Temperature Coefficient Pmax %/K -0.38 NOCT (t 2°C) °C 45 • • • • Operating temperature °C 40/+85i • ` • • . • Mechanical Properties and Components . • Module weight (t 1 kg) kg 19 • Dimensions (H x L x D; i 1 mm) mm 1650 x 990 x 38 • • • • • • Maximum surface load (wind/snow)* N/m2 5400 — • • • , • • • • Hail im act resistance m 25 mm at 83 kmlh Cells 60 - Si monocrystalline - 4 or 5 busbar - 156.73 x 1 SE 75 raime • • • • • • • Glass 3.2 mm high transmittance, tempered, antireflective co,i v • • • Backsheet — — Muldlayer poiyester-based • • �!� • Frame Anodized Al • • • B ss diodes 3 diodes-45V/12A, IP67/IP68 Cables and connectors (See installation manual) 1200 mm o 5.7 mm (4 mm2), MC4 compatible ; •' • Module product warranty 12 years • • • • 25 years z 97%end of I- year 4 Linear power performance guarantee z 90% end of 129, year s 82% end of 250, year 3 ULCORD C1703, UL 1703, IEC 61215, IEC 61730, IEC 61701, CEC listed E Product _w IEC 62716 Ammonia Corrosion, IEC 61701:2011 Salt Mist Corrosion_____ fl _ -_ _ — UL Fire Rating. Type 2 (Type 1 on request) factory IS09001:2015 Warning: Read the installation and User Manual before i34 handling, installing and operating modules. [1 t ar ungnp-_` I � Third -party generated pan files from Fraunhofer-Institute for Solar Energy i Systems 15E are available oNv-GL ' a for download at: '�\ 7i12 � www.silfab.caldownloads ,, .ter Mooidny51° �` I - ;� Modules Per Pallet: 26 [ 1yJ e Pallets PerTruck: 36 »e Modules Per Truck:936- i.. c h°RlecSOLA View ;• SilfaOt�``� , 1 _i w2>.?1..... N•m R�. 9 Silfab Solar Inc 6rew6p T«„•««._,m« 240 Courtneypark Drive East • Mississauga, "OI°•r� -r ttm° ^•«• Ontario Canada LST 2S5 Tel +1 905-255-2501 • Fax +1 905-696-0267 sse s info@silfab.ca • wormsilfab.ca REV DESCRIPTION DATE DESIGNER CONTACT INFORMATION— alwaa Wit COMPANY CONTACT INFO COMPANYLOGO 00TITAN s 0 !_ a R P 0 w E R - CUSTOMER DAVID SMITHERMAN SHEET NAME DATE SHEET -- - - - - - - - -- - - -- --- - - ENGIPARTNERS,.32661 LLC C.A. 32661 � 330 SW 27 AVE STE 508 MIAM1,FL33135 ,0 RGONZALEZ@ENGIPARTNERS.COM ' 11 786-393-4740 TITAN SOLAR POWER FL, INC. 111411 a = 12221 N US HIGHWAY 301 �� THONOTASASSA, FL 33592 STATE OF /� ' •' OIRZ 3P- •. (813)982-9001 SQ * ' . • ... • , . ' 71EC13008093 -- - - PROJECT PV GRID -TIED 5.1 KW DC / 7.6 KW AC STRING INVERTER SYSTEM ADDRESS 570 NW 112TH ST, MIAMI, FL 33168, USA PROJECT ID TSP25939 INSTALL DETAILS SHINGLE DESIGNED BY ENG. RAFAEL A. GONZALEZ SOTO, PE DATE 07/01/2019 SHEET TITLE D-1 - SHEETS 6OF8 - PARCEL NUMBER FOLIO: 11-2136-021-0620 Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 25 YEAR WARRANTY ------------ I -., ..... P,a .*�..,.m.�.,.. ELrL.."O,! PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters J Up to 25% more energy J Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading I Flexible system design for maximum space utilization • 19 Wj L7 J N m ! Fast installation with a single bolt Next generation maintenance with module - level monitoring J Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) / Module -level voltage shutdown for installer and firefighter safety solaredge.com ��``\ p, GONZaI.F o I a r a• `-AGE N SF SO P. O DATE DESIGNER CONTACT INFORMATION ENGINEERING STAMP COMPANY CONTACT INFO ENGIPARTNERS, LLC IIK (/1/1//I,'I/('1'/}=TITAN SOLAR POWER FL, INC. C.A. 32661 12221 N US HIGHWAY 301 330 SW 27 AVE STE 508 STATE OF :!,/ MIAMI, FL 33135 THONOTASASSA, FL 33592 RGONZALEZQENGIPARTNERS.COM ' FC O la �` (813) 982 -9001 786 - 393 - 4740 ®fJAY� #EC13008093 /I 111It Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 P340 P370 P400 P505 Optimizer model P320 high- (for higher- 72 & 96- P405 higher (typical module 60-cell (for Po cell power (for cell (for thin (for current compatibility)(for modules) modules) moodules) 60 and 72 cell modules) modules)m modules) modules)INPUT DC PoverI . ax r�crr rp;11 ;trcnt �r .r • Ma<:mLrr hf5rfr..• +9 $ z• • • � rKeahtedElF„en y Se.S si65 % a+er rota atecp ry -_ --_. _ _ • OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) •"' •' MdX I'RIr1 OJ `Jt CU'ef., . `. r_ *0 0 0 OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE • • • • • • INVERTER OFF) • • 00 Safety GJtput VC t ce pe' ' x 0 i • Pmer Cptrncet • • • STANDARD COMPLIANCE • • • E`d� — FQ tit,.lzs<3 r.tr'OC-. <. iEC51�3C�6-? ---- • • . a*rY ih(6a I0r/ I [ a,, 11 utry; .A'74'. • • INSTALLATION SPECIFICATIONS tldxt— l"r Aluwed $yftenl I?'fl' Jdr 1a a Cow-at•,cle inverter; At Sc ztEcge S'ige Phase aid 'tree P'tase r:erters _ _ — Gmensors ONxLxH; _ '.29v1i3x3351 29x lit x�9.$I 1 9x 62 f, 129x`J3x2;.J1.,'x6xt1 mmlir, --. -3 S.IxE?xt9 �.-x5.4.7.1 -5:?C,'.4 'Ut4:c.s } heghtIll LlJdrecaues; - G;'.7 8�$,''9 rr(le hPJ..r.omectO MC.-° I outppr yq e')pe Conne_tr_r DoibLe b`•.wlatec, MC4 Outpx 4vrn aigti ass r 1.0 t.% J 39 m l k 6npr. Wire -engh O lb / 0 2 IT ,I Oper>vng Temperature Range -40 - tc S r -40 - -185 'C Uurl Pa. rg Me t 14[MA6P ——% ! _ _F-.f Rciaii><e -t rnd`ry 0 -1C0 ' �a>°d ST< Paa,+er c' 11° rz�xvk. NGduE d ua to $% axe rter;n:o ai:�sved 'W M7re:1arxnuz iryar.,.9 ter ix;l _,.«If.,-8-W `Ic-Oh',Cae^r.-I", Sy:_:t�asa Ls�ac[ Szi.,Lp MinimJnt Strng Leng-h 20. (Pote,f Opuif Maxireurl S, i)g Le,,gti Maximum Ferrer cer String SE'6a0- S SEt73;P;}- J24 6cw te'SIY vw' Jc P,ralle Stn1 qi d Diferert:.engix- cr Oricn-..nan; C' cenOJ vn?'D�q'd'm -w rote, to Htp:!r ,S.ob=acezc—fs t<; d@7=uli/fil=s: si axU r zog V rd, ` It? •ram allarsed to mv.14CMTY,5i rdh P3>_Q`34&11370/F40C i re s -g A4—::,ibrrx: e• It ai r Snr::ruirx,e t,kern:rvd"wl -1f.'ut%:1KUSl� iiKV`,it,Sa4_ t0n.I.p1C;`d1CJ:Pe'i."*I'Y�w1•.cry39fi0.?; afPLLr•>'r.I:dt`the i'r+_nef f:�'nC5 Pe'u'1r. IOr SL41ZKJSI d�3 f:tp� tr. m�: mum gave• C4-mXC x1w , t-..1NS is w to 1;:w0 ; FC- k?XUS%1E33.XUS,SE64z..6KU: SEICOWS., 8 4 alk.r :, ratol V b 15,0(1Cv:' pe' ^i-,g vl-.=_n 3 std— a cx mcl M he i'r. G It,-3 Fe' irk f, SE55.60SiSE4 CKUS• drai w'an kr nwiuen„ :z .xri cATetrrx a txr1w — IIw Mre j, i, tq: r: J O..:fM 0 Sr4a49k:tuuWyes LIA AY r jil, rcesrveJ. SCIAA1:Mt. If, Sota09, krp, W'II D3Y WIA41, 4> ere ItaJrnrarkr wn+yotavert tr kW *aofb tL dge iarlaNkryin Ere. tea at rttaaemaMs mtmlr�rmJ twrnn are baiNnarks of 0­restxcl,rew:rurs.D-12/2%V.10L2RG" S.W1, m:h-ge*4fw mf" COMPANYLOGO 01D TITAN 5 0 L A R P O W E R CUSTOMER DAVID SMITHERMAN PROJECT PV GRID -TIED 5.1 KW DC / 7.6 KW AC STRING INVERTER SYSTEM ADDRESS 570 NW 112TH ST, MIAMI, FL 33168, USA PARCEL NUMBER FOLIO: 11-2136-021-0620 SHEET NAME CE ROHS DATA SHEET a • •••• •••••• • a • • a • • PROJECTID DESIGNED BY SHEETTITLE TSP25939 ENG. RAFAELA. GONZALEZ SOTC, PE I]-2 INSTALL DETAILS DATE I SHEETS SHINGLE 07/012O019 7 OF SolarEdge Single Phase StorEdgeTM Solutions for North America SolarEdge StorEdgeT1 Solutions Benefits: More Energy - DC -coupled architecture stores PV power directly to the battery without AC conversion losses — Simple Design & Installation - single inverter for PV, battery storage, grid -tied and backup applications Enhanced Safety - no high voltage during installation, maintenance or firefighting a Full Visibility - monitor battery status, PV production, remaining backup power and self -consumption data USA-CANADA-GERMANY-iTALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHER.LANDS-UK�S,t Fljd TVIFAKl-BULGARIA www.solaredge.us �Q�G • ' �,�C E N 3F �0 —O-� REV DESCRIPTION DATE DESIGNER CONTACT INFORMATION ENGINEERING STAMP COMPANY CONTACT INFO _ ENGIPARTNERS, LLC C.A. 32661 330 SW 27 AVE STE 508 MIAMI, FL 33135 RGONZALEZ@ENGIPARTNERS.COM 786-393-4740 /yNil(l/ 4/ / ..•• / /Z,1/]�� 1 A'•. STATE OF ` *t o p' ..... ///�IOuAL ` 'TITAN SOLAR POWER FL, INC. Ii. 12221 N US HIGHWAY 301 �V k/ THONOTASASSA, FL 33592 \\ (813) 982 -9001 \ \ #EC13008093 --- — _ - - - _ - sv I a r " • SolarEdge Single Phase StorEdge Inverter for North America SE7600A-US'`! Single inverter for PV, grid -tied storage and backup power Includes the hardware required to provide automatic backup power to backed -up loads in case of grid interruption Includes all interfaces needed for battery connection SE760CA-US ... 1 OUTPUT -AC (LOADS/GRID) COMPANYLOGO Rated AC Power Output 7600 VA Max AC Power Output 8350 VA AC Output Voltage Min-Nom-Max(L-L)" 211-240-264 Vac. AC Frequency Min-Nom-Max:';... ._..... _ _.. ._ _.._ .. _59.3-60-60.5 Nz_.. _ Maximum Continuous Output Current @240V 32 A GFDI 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Charge Battery from AC (if Allowed) Yes • • • • Power factor with rated power .... >0.99 (configurable; 0.9 leading to 0.9 tagging) • • • • • • • Typical Nighttime Power Consumption <5_. Vd • • OUTPUT-ACjBACKUPPOWER�t--- _ ..._......................_....... .._..-.-......_._.. -....._ ---�--__.._____------_.._ •••:•• a• • • • • • • • Rated AC Power Output 5000,4i • P,� • • • • • Max AC Power Output - Surge _....._. ___.. _...__ .. __..... .._ 6600... L4.0.0... • • • • ACOutput Voltage Min-Nom-Max(L-L) . 211240-264 �i'i••. • AC Output Voltage Min-Nom Max L-N 105-120-132 V r, ••••• • AC Frequency Min-Nom-Max SS GO- 65 • i i • • • �J• • • • • • • • • � • • Maximum Continuous Output Current @240V - Backup Mode 21 • �� • • • • • • • • • • Max Conhnuous Output Current per Phase @120V 2S • l• • • _.... _. _.__.. ..._.... .. .. .-. ._._ 1 - ......-. __ • • A • • • •••••• AC Circuit Breaker Yes • • • • • THD... ..._.. ...... .__ _ .. .__. ...._ _ ._ ..... <S •- • • 4 • • • Power factor with rated power 0.2 leading to 0.2 lagging • • • Automatic switc hover time <2 sec Typical Nighttime Power Consumption <5 VU _ ------- — _...... INPUT DC (PV and BATTERY) - .......... ...... ... - .. — — ...._... - - Transformer -less, Ungrounded Yes Max Input Voltage 500 Vdc Nom DC input Voltage 400 .._... _...._ Vdc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 6001ic0 Sensitivity Maximum Inverter Efficiency 98 % CECWeightedEffciency-_.- - -- -.97.5 'Y INPUT DC PV Maximum DC Power (STC) 10250 vi ..__._. u._.. .__ ... .......... .........__ ...............................___....__....._._. M ax InputCCurrents"' __ _.. _..._,...._._. .._................._.__. 23 ....__... Adc 2-pole Disconnection Ves INPUT DC (BATTERY) Continuous Peak Power 3300 W Number of Batteries per Inverter` i 2 for high capacity Supported Battery Types LG Chem RESU 1 0 H Testa Powerwall 1 TesIl'Rowerwap 1.. Max Input Current 8.5 Adc 2-pale Disconnection Yes DC Fuses on Plus and Minus 12A 11 (field replaceable) AUUrI IUNAL FtAI URL5 Supported Communication Interfaces RS485 for battery, RS485, Ethernet, ZigBee (optional) Battery Power Supply. Yes, 12V / 53W Revenue Grade Data, ANSI C12.20 Optionali'' Integrated AC, DC and Communication Connection Unit Yes AC Disconnect Yes Manual Inverter Bypass Switch Yes DC Voltage Rapid Shutdown RV and Battery) Yes, according to NEC 2014 690.12 Auto -transformer thermaEprotection Yes "I These specifcatona apply to inverters Minh part numbers SE7600A-USSOXXXXX and connector, unit model number BCu-lPH-uss to for other regional settings please contact SolarEdge support I Not designed for standalone appfications and recce res AC for commissioning I The rated AC power output is the minimum between 5000VA and the battery continuous peak power Is- A higher current source may be used, the inverter wnl Limit its input current to the values stated ter For two batteries for double power contact SolarEdge technical support 1a Revenue grade inverter P/N: SE760OA-USS02NNG2 TITAN S 0 L A R P 0 W E R CUSTOMER DAVID SMITHERMAN PROJECT PV GRID -TIED 5.1 KW DC 17.6 KW AC STRING INVERTER SYSTEM ADDRESS 570 NW 112TH ST, MIAMI, FL 33168, USA PARCEL NUMBER FOLIO: 11-2136-021-0620 SHEET NAME DATA SHEET PROJECTID DESIGNED BY TSP25939 ENG. RAFAEL A. GONZALEZ SOTO, PE INSTALL DETAILS DATE SHINGLE 07/0112019 SHEET TITLE D-3 SHEETS 80F8