MC-18-3420Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
Issue Date:11/27/2018
Parcel Number
138 NE 109 ST, Miami Shores, FL 33161-7042 1121360090130
Contacts
Permit NO.: MC-1 1 -18-3420
Permit Type: Mechanical - Residential
Work Classification: Alteration
Permit Status: Approved
Expiration: 05/08/2019
EAL INVESTMENT INC Owner EAL INVESTMENT INC Applicant
138 NE 109 ST, MIAMI SHORES, FL 33161 138 NE 109 ST, MIAMI SHORES, FL 33161
Other:7863160828 Other:7863160828
INFINITY CONSTRUCTION SERVICES INC Contractor
ANTONIO LUVARA
4156 96 AVE, MIAMI, FL 33165
Business: 7864439590
Description: INSTALL NEW MACHINES OF A/C COMPRESSOR Valuation: $ 4,000.00 Inspection Requests:
AND CONDENSER
TotalSq Feet: 0.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$2.40
DBPR Fee
$2.10
DCA Fee
$2.00
Education Surcharge
$0.80
Permit Fee
$90.00
Scanning Fee
$9.00
Technology Fee
$3.50
Total:
$159.80
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$159.80
Check# 1397
11/27/2018 $109.80
Check # 1388
11/09/2018 $50.00
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regula%gponstruction and zoning. Futhermore, I authorize the above named contractor to do the work stated.
-Cf-a Y70LA-elo, // -d-;7 ^,',P
Signature: Owner/ / Applicant / ContractoY / Agent Date
November 27, 2018 Page 2 of 2
\9 Miami Shores Village
RECEIVED
.j
BUILDING
Tj\ Building Department
10050 N:E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
PERMIT APPLICATION
❑BUILDING ❑ ELECTRIC ❑ ROOFING
NOV 0 9' 2018
Cph V "
FBC 2014
Master Permit No.1�8-1310
Sub Permit No. 1� 1C 1
❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING 0 MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 138 NE 109TH Street, Miami Shores, FL 33161
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#:11-2136-009-0130 Is the Building Historically Designated: Yes NO X
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): EAL INVESTMENT INC Phone#:786-316-0828
Address:13499 Biscayne Blvd #TS3
City: Miami state: FL Zip: 33181
Tenant/Lessee Name:
Email: israelcamposdeleon@hotmail.com
CONTRACTOR: Company Name: Infinity Construction Services, Inc Phone#: 305-761-7937
Address: 6955 NW 77th Avenue Suite 310
City: Miami
Qualifier Name: Antonio LUyara
FL Zip: 33166
Phone#: 305-761-7937
State Certification or Registration M CAC1816795 Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State:
00
Value of Work for this Permit: $ A�. ovo = Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration M New ❑ Repair/Replace
Description of Work: Install new machines of A/C, compressor and condenser
Specify color of color thru tile:
Zip:
❑ Demolition
Submittal Fee $
Permit Fee $
V U
CCF $ CO/CC $
Scanning Fee $
Radon Fee $
Z r'Al
i
DBPR $ 2 / b Notary $
Technology Fee $ Training/Education Fee $
Double Fee $
Structural Reviews $
(Revised02/24/2014)
Bond $
TOTAL FEE NOW DUE $ 1 O�'t • �Z�
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
4
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued in the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
��OWNER or AGENTV'ndva-_�--
The foregoing instrument was acknowledged before me this
0 & day of 20 /Q by
E�4e-,IA A:-odroqAA, is personally known to
me or who has produced L• .%L. as
identification and who did take h. ChristyM. Cruz
NOTARY PUBLIC: NOTARY PUBLIC
STATE OF FLORIDA
Comm# GG11
Expires 6/26/202/2021
Print:
Seal:
Signature /7_7�
CONTRACTOR Op 4�1 �1 10 ouQr,
The foregoing instrument was acknowledged before me this
0& day of ��' 20 11 , by
Y1�i✓Lt tQ l av/Zwho is personally known to
me or who has produced 7�L Z: • as
identification and who did take an ► ChristyM. Cruz
Q on NOTARY PUBLIC
NOTARY PUBLIC: -STATE OF FLORIDA
a Comm# GG119046
s�-CE 19�0 Expires 6/26/2021
Sign:
Print:
Seal:
711*
APPROVED BY Plan Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
11/9/2018 Property Search Application - Miami -Dade County
Vy
0
E PRA
FACEOFTHEP""OPUTYft
.-
Summary Report
Property Information
Folio:
11-2136-009-0130
Property Address:
138 NE 109 ST
Miami Shores, FL 33161-7042
Owner
EAL INVESTMENT INC
Mailing Address
13499 BISCAYNE BLVD # TS3
NORTH MIAMI, FL 33181 USA
PA Primary Zone
1000 SG FAMILY - 2101-2300 SQ
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
2/2/0
Floors
1
Living Units
1
Actual Area
1,780 Sq.Ft
Living Area
1,412 Sq.Ft
Adjusted Area
1,588 Sq.Ft
Lot Size
9,300 Sq.Ft
Year Built
1951
Assessment Information
Year
2018
2017
Land Value
$232,690
$232,690ET2016
874Building
Value
$110,525
$110,5255
55
XF Value
$1,800
$1,800
$1,800
Market Value
$345,015
$345,015
$312,199
Assessed Value
$345,015
$110,523
$108,250
Benefits Information
Benefit
Type
2018
2017
2016
Save Our Homes Cap
Assessment Reduction
$234,492
$203,949
Homestead
Exemption
$25,000
$25,000
Second Homestead
Exemption
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
IShort Legal Description I
DUNNINGS MIAMI SHORES EXT NO 5
PB 48-21
LOT 5 BLK 216
LOT SIZE 75.000 X 124
OR 12587-754 0785 4
Generated On : 11/9/2018
Taxable Value Information
2018' 2017� 2016
County
Exemption Value
$0
$50,000
$50,000
Taxable Value
$345,015
$60,523
$58,250
School Board
Exemption Value
$0
$25,000
$25,000
Taxable Value
$345,015
$85,523
$83,250
City
Exemption Value
$0
$50,000
$50,000
Taxable Value
$345,015
$60,523
$58,250
Regional
Exemption Value
$0
$50,000
$50,000
Taxable Value
::]$345,015
$60,523
$58,250
Sales Information
Sale Previous Price i9
O Pa e Bo k Qualification Description
10/05/2017 1$325,0001 30770-3185 Atypical exposure to market; atypical
motivation
I10/05/2017 $303,000� 30714-2530 Atypical exposure to market; atypical
motivation
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property
Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
11/9/2018
Detail by Entity Name
ffivisao.,j tr iiORPOrz„r-)NZ
jo
s
j' L)l /L"jol I fJ/'�
/ ram,-0r 1 Ji f''P(Y I"C i
Department of State / Division of Corporations / search Records / Detail By Document Number /
Detail by Entity Name
Florida Profit Corporation
EAL INVESTMENT INC.
Filing Information
Document Number
P11000043554
FEI/EIN Number
90-0715841
Date Filed
05/05/2011
Effective Date
05/01/2011
State
FL
Status
ACTIVE
Principal Address
13499 BISCAYNE BLVD
TS3
NORTH MIAMI, FL 33181
Changed: 03/27/2018
Mailing Address
13499 BISCAYNE BLVD
TS3
NORTH MIAMI, FL 33181
Changed: 04/24/2015
Reaistered Aaent Name & Address
Andrada, Andrea N.
13499 BISCAYNE BLVD
TS3
NORTH MIAMI, FL 33181
Name Changed: 01/05/2016
Address Changed: 04/24/2015
Officer/Director Detail
Name & Address
Title P
Andrada, Andrea N.
13499 BISCAYNE BLVD
TCQ
http://search.sunbiz.orgtinqui ry/CorporationSearch/SearchResultDetail?inquirytype=En*Name&directionType=Initial&searchNameOrder=EALINVESTM ENT... 1/2
v
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Notice to Owner —Workers' Compensation Insurance Exem
Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05
allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to
obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure:
An employer in the construction industry who employs one or more part-time or full-time
employees, including the owner, must obtain workers' compensation coverage. Corporate officers
or members of a limited liability company (LLC) in the construction industry may elect to be
exempt if:
1. The officer owns at least 10 percent of the stock of the corporation, or in the case of
an LLC, a statement attesting to the minimum 10 percent ownership;
2. The officer is listed as an officer of the corporation in the records of the Florida
Department of State, Division of Corporations; and
3. The corporation is registered and listed as active with the Florida Department of
State, Division of Corporations.
No more than three corporate officers per corporation or limited liability company members are
allowed to be exempt. Construction exemptions are valid for a period of two years or until a
voluntary revocation is filed or the exemption is revoked by the Division.
Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use
day labor, part-time employees or subcontractors for your project. The contractor has provided an affidavit stating that he or she will
be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of
workers' compensation insurance coverage from the contractor's company for day labor, part-time employees or subcontractors.
BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS
CONTENTS.
Signature:
Owner
State of Florida </
County of Miami -Dade
The for going was ackn ledge before e this day of , 20
who is personally known to me or has produced
as identification.
Notary: NR1' Christy M. Cruz
NOTARY PUBLIC
SEAL: , i STATE OF FLORIDA
{ COMM# GG119046
Expires 8/26/2021
INFINITY CONSTRUCTION SERVICES INC.
6955 NW 77TH Avenue suite 310, Miami, FL 33166
LICENSE MECHANICA: CFC1816795
LICENSE PLUMBING: CFC1428288
.• •
• .
Date:10/22/2018
...:..
State Florida
of
.••••.
•••••
•
County: Miami Dade
....
....
.....
•�����
�•
����•.
.. ..
....
••.••.
Before day Antonio Luvara
Who being duly *;deposes
°and
• 40
me this personally appeared. savor
40
000000
says:
�.....
. .
•••...
00
That he will be the only person working in the project at 138 NE 109TH Street, Miami Shores
FL 33161
6ontractor Signature
Sworn to (or affirm) and ubscribed before me �� this day of CJ 2018.
By ABM E/G V ()&I -a .
Personally Know Or produced identification �xL:
Print, type or stamp name of Notary
Chrfsty M. arz
NOTARY PUBLIC
STATE OF FLORtDA
0� Comm# GG119o46
SCE 191 Expires 6/26/2021
FORM R405-2017
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST.
Florida Department of Business and Professional Regulation • 0 • • •
Simulated Performance Alternative (Performance) Method.:::*-•' 00' 0.
Applications for compliance with the 2017 Florida Building Code, Energy Conservat"PtWthe •
residential Simulated Performance Method shall include: • • • •
.. 0 .. .
This checklist •
A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a -ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (one page) and an input summary checklist that can
be used for field verification (usually four pages/may be greater).
AEnergy Performance Level (EPL) Display Card (one page)
^6 HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
qMandatory Requirements (five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report (usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report (usually one page)
.• 4"
_ NO
• ss>
AT OF ;
L .E�`�' .
'rir:of1rtam;�;,
9/12/2018 12:11:37 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential PeVorngance �IAetAad .. ......
•
Project Name: REMODELING @ 138 NE 109th St
Builder Name:
• • • : •
• •
Street: 138 NE 109th St
Permit Office:
"' • •' •
•
City, State, Zip: MIAMI SHORES, FL,
Permit Number.
. "". • "" •
Owner.
Jurisdiction: 231000
Design Location: FL, Miami
County: Miami -Dade (Florida Cliff!hnZdhD 1) ; .' • .
•• ••••
••
1. New construction or existing Addition
9. Wall Types (1490.0 sgft.)
;' insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
' R=3.6 1tppgIt
'
b. Concrete Block - Int Insul, Adjacent Rs3.9 1"10.00 ft'
•
3. Number of units, if multiple family 1
c. N/A
• R= • " fc'
'
4. Number of Bedrooms(Bedrrns In Addition) 3(1)
d. N/A
R= • • n=
10. Ceiling Types (1345.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=19.0 1345.00 ftZ
6. Conditioned floor area above grade (W) 1345
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c.
11. Ducts
R= ft'
R ft'
7. Windows(138.9 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 280
a. U-Factor. Sgl, default 138.90 ft'
SHGC: Clear, default
b. U-Factor. N/A ft'
12. Cooling systems
kBtufir Efficiency
SHGC:
a. Central Unit
41.5 SEER:16.00
c. U-Factor. N/A ft'
SHGC:
13. Heating systems
kBtufir Efficiency
d. U-Factor: N/A ft'
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.800
14. Hot water systems -Replacement equipment
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (1345.0 sgft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 1345.00 ft'
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Area: 0.103 Total Proposed Modified Loads: 60.00
PASS
Glass/Floor
Total Baseline Loads: 63.84
1 hereby certify that the plans and specifications covered by
Review of the plans and
OF THE STgTF
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
y , " z,;=
,
with the Florida Energy Code.
01
, .
PREPARED BY: /✓ n r G Or
Before construction is completed
Cie -
DATE: e4 r
this building will be inspected for
compliance with Section 553.908'
0
e
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure quallfies' gill l e/ro�r,✓t
certified factory -sealed In accordance with R403.3.2.1. �a��" CAiI'I (�� `A°✓,..
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1°and thls•proJect,rei�' I ' * an
envelope leakage test report with envelope leakage no greater than 4.01 ACH50 (R402.4.1.2).
- Compliance requires a roof absorptance test and a roof emittance test in accordance with 111405.7:2 /jj
c!7 .lQ Or •
9/12/2018 12:11 PM EnergyGauge® USA Section R405.4.1 Compliant Software ✓,, /�y ' • 'S/t7 Page' 1 ot'4 -
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
REMODELING @ 138 NE 10 Bedrooms: 3
Address Type: Street Addiess
Building Type:
User
Conditioned Area: 1345
Lot # • • : • • •
• • • •
Owner Name:
Total Stories: 1
Block/Su&9IwI1io& • •
•
# of Units:
1
Worst Case: No
PlatBook; ""' •
Builder Name:
Rotate Angle: 0
Street: • • ; • • 138 NE 1 Q9th St
•
Permit Office:
Cross Ventilation: No
County: • • • • Miami-&dq
Jurisdiction:
231000
Whole House Fan: No
City, Starh,jiQ:• • MIAMI.,%gRES ,
•, • •
Family Type:
Single-family
FL,
New/Existing:
Addition
go
• • • • •
Comment:
•• •• ••••
••••
CLIMATE
Design Temp
Int Design Temp Heating aDes ign • Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, Miami FL_MIAMI_INTL_AP 51 90
70 75 149.5 56
Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1345 13450
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfIIID Finished Cooled
Heated
1
Main
1345 13450 Yes 5
3 1 Yes Yes
Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatlo Main 168 ft 0
1345 ft' 1 0
0
ROOF
/
Roof Gable Roof
Solar SA Emitt Emitt Deck
Pitch
V #
Type
Materials Area Area Color
Absor. Tested Tested Insul.
(deg)
1
Gable or shed
Barrel tile 1457 ft' 280 ft° Medium
0.75 Yes 0.9 Yes 0
22.6
ATTIC
J#
Ratio
Area RBS IRCC
Type
Ventilation Vent (1 in)
1
Full attic
Vented 300 1345ft2 N Nat
CEILING
#
Ceiling Type
Space R-Value Ins Type Area ; •Framing; Frac`J�i Cn{s� hype':
;
1
Under Attic (Vented)
Main 19 Blown
1345 it' r �',� Wood
-
LP 0
3cn, ,' 1
Q
9/12/2018 12:11 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
BI ck
. Ducts
1 Electric Strip Heat/Replaceme None
COPA
34 kBtu/hr
• •
00
1: • ` `sys#1 .
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
iiiilBI
Ducts '
1 Central Unit/Replacement for
None
SEER: 16 41.5 kBtu/hr 1400 cfm
• • a 7i'0
10. •. • sys#1 •
HOT WATER SYSTEM
• • • •
• • • • •
# System Type SubType
Location
EF Cap
Use
SetPnt
; ' �onservption . .
1 Electric Tankless
Main
0.99 1 gal
70 gal
120 deg
• •
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft'
DUCTS
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic 6 280 ft'
Attic
80 ft' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan [X] Feb DQ Mar
Heatinf X Jan [X] Feb Pq Mar
[XJ Apr
[X] Apr
[X] May [X] Jun X] Jul
[X] MaY [X] Jun f X] Jul
AugX]
f Au[X]
Se
Sep
[X] Oct
[X] Oct
Nov
Nov
Dec
Dec
Van- [X] Jan [XJ Feb Pq Mar
[XJ Apr
[X] Ma [Xl Jun [XJ Jul
[ Aug
[X] Se
[Xl Oct
Nov
Dec
Thermostat Schedule: FloridaCode 2014
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WO) AM 75
75 75
75 75 75
75
75
75
75
75
75
PM 75
75 75
75 75 75
75
75
75
75
75
75
Cooling (WEH) AM 75
PM 75
75 75
75 75
75 75 75
75 75 75
75
75
75
75
75
75
75
75
75
75
75
75
Heating(WD) AM 72
72 72
72 72 72
72
72
72
72
72
72
PM 72
72 72
72 72 72
72
72
72
72
72
72
Heating(WEH) AM 72
72 72
72 72 72
72
72
72
72
72
72
PM 72
72 72
72 72 72
72
72
72
72
72
72
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft'
Oft
0.3
Main. — . .
V'-- .1% or —04"'o
1
Name: Signature
Rating Compant:. Date:
U _ yy 4: No. 675T4
STATE of -
,o���S' F�ORIDP
''''•,, ONA L
9/12/2018 12:11 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framipg6 Solar
Below
#
nrnt
To
Wall
Type•R-Vallie
Space
Et
In
Et In
Area
-
1
S
Exterior
Concrete
Block - Int Insul
Main
3 46
0
10
460.0 ft'
• • �
0 * .3
0
-
• •
•
•
.2
E
Exterior
Concrete Block - Int Insul
Main
3 35
0
10
350.0 ft-
• • • • •
0 ; • * * 3
..Q.:
3
N
Exterior
Concrete Block - Int Insul
Main
3 46
0
10
460.0 ft"
... • •
0 • 0.3
•
4
W
Exterior
Concrete
Block - Int Insul
Main
3 11
0
10
110.0 ft'
000001,
0 ."`Z1.3
` 0
5
W
Garage
Concrete Block - Int Insul
Main
3 11
0
10
110.0 ft'
0 0.01
002041
-
••••••
• ••
DOORS
�• •�
••••
••••
#
Omt
Door Type
Space
Stones U-Value
WAh •
Heni .;•
�n
Arel
Ft
• In*
Ft •
•
1
S
Wood
Main
Wood
.46
3
• • •
7 • 04000
21 ft•
2
W
Wood
Main
Wood
.46
3
7 " `
21 ft'
3
W
Wood
Main
Wood
.46
3
7
21 ft'
WINDOWS
Orientation shown is the entered, Proposed
orientation.
Wall
Overhang
V
#
Omt ID
Frame
Panes NFRC
U-Factor SHGC
Imp Area
Depth
Separation
Int Shade
Screening
1
S 1
Metal
Single (Clear)
No
1.2 0.8
N
20.1 ft2
2 ft 0 in
1 ft 4 in
None
None
2
S 1
Metal
Single (Clear)
No
1.2 0.8
N
20.1 ft'
2 ft 0 in
1 ft 4 in
None
None
3
S 1
Metal
Single (Clear)
No
1.2 0.8
N
3.7 ft'
2 ft 0 in
1 ft 4 in
None
None
4
S 1
Metal
Single (Clear)
No
1.2 0.8
N
3.7 ft'
2 ft 0 In
1 ft 4 in
None
None
5
S 1
Metal
Single (Clear)
No
1.2 0.8
N
3.7 ft'
2 ft 0 in
1 ft 4 in
None
None
6
E 2
Metal
Single (Clear)
No
1.2 0.8
N
3.7 ft'
2 ft 0 in
1 ft 4 in
None
None
7
E 2
Metal
Single (Clear)
No
1.2 0.8
N
3.7 fN
2 ft 0 in
1 ft 4 in
None
None
8
E 2
Metal
Single (Clear)
No
1.2 0.8
N
1.4 ft'
2 ft 0 in
1 ft 4 in
None
None
9
N 3
Metal
Single (Clear)
No
1.2 0.8
N
10.0 ft'
2 ft 0 in
1 ft 4 in
None
None
10
N 3
Metal
Single (Clear)
No
1.2 0.8
N
14.9 ft'
2 ft 0 in
1 ft 4 in
None
None
11
N 3
Metal
Single (Clear)
No
1.2 0.8
N
33.9 ft'
2 ft 0 in
1 ft 4 in
None
None
12
N 3
Metal
Single (Clear)
No
1.2 0.8
N
20.0 ft°
2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
240 ft'
240 ft'
44 ft
8 ft
1
INFILTRATION
•Iti:.e oa..
PN�
/v'
#
Scope
Method
SLA CFM 50 ELA
EgLA
.>
ACH e�x'ACH•50 • • • ..
1 Wholehouse Proposed CFM(50) .000255
900 49.41
92.92
.1868�`
4.0
9 ` J�C
01514
' SFAEO
ae� • F Fop
.•4�.�
11 /DNA L E�
�I'oetf;fltitik%W'
9/12/2018 12:11 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ;...;.
ESTIMATED ENERGY PERFORMANCE
•
INDEX* = 94 : .9.
•• •
The lower the Energy Performance Index, the more efficient the homy• • •
...... •
.... ....
1. New home or, addition
1. Addition
6600 0000
12. Ducts, location & insulatiop jqvA . . ..
a) Supply ducts ••••••R '•
2. Single-family or multiple -family
2. Single-family
b) Return ducts R 6.0
• • • • • •
c) AHU location • • Attic/Attic
3. No. of units (if multiple -family)
3. 1
•0 0 0•
4. Number of bedrooms
4. 3
13. Cooling system: Capacity tT.t.' .
a) Split system SEER •' '
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1345
d) Room unit/PTAC EER
e) Other 16.0
7. Windows, type and area
a) U-factor:(weighted average)
7a. 1.200
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.800
14. Heating system: Capacity 34.0
c) Area
7c. 138.9
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP 1.0
a) U-factor:(weighted average)
Be. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, Insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.99
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 3.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10132. 3.0
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
118. 19.0
b) Cross ventilation No
b) Single assembly
11b.
c) Whole house fan No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. `'`Qvtltip911hir;p,'�
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above ene gyp lx 0. ill°�%y,
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL 'C
display card will be completed based on installed code compliant features.
* ' N0 s?s?
Builder Signature: Date:_ 4
X1 TATF OF
Address of New Home: 138 NE 109th St City/FL Zip: MIAMI SHORES. F.L• _' . nn;
°�e. ��✓A L EIA
i.�4j),r14t4199sere`°ar
9/12/2018 12:11:50 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 138 NE 109th St Permit Number.
MIAMI SHORES, FL, : • • • : •
•••
MANDATORY REQUIREMENTS See individual code sections for full details.
I
SECTION R401 GENERAL
. • • • • •
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energ lm%. rmanc4 IeyM %PL) " • "
display card be completed and certified by the builder to be accurate and correct before final approval of the buildingo0eacupancy. F4ciWa law • • • • • •
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales copUU"both presold and . •
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level eand affivencies of corponents • • • ;
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately wefleets the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can bo foupa yi AppeRdix RD. • . • ...
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveloT3he building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed In accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third parry shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth In Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
Infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. W�e reusing i
aces listed and
ed
dance
MIYA
fireplace. Where us doors
tight-fitting n dootrs onlmasonry fireplaces, Itheldoorrss shall be with
d and labeled in accordance tested
with C,9�Q7 U # %i fCC r`ZJis
R402.4.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of ho more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested accordinq'to NFRC 400 S 1 l i
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Nn. ;! w
STA C :
Exception: Site -built windows, skylights and doors. Ci-
� •' 1� �00
''�fatlatttt,��:
9/12/2018 12:11 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 1 of 5
-MANDATORY REQUIREMENTS - (Continued)
❑R402.4.4 Rooms containing fuel-buming appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the biiiding thermal "9150if or .... e
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope equirements • •
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door in6the Lom shall be •
fully gasketed and any water lines and ducts In the room Insulated In accordance with Section R403. The combustidM4ilrA& shall lie Insulated wheld' I • •
passes through conditioned space to a minimum of R-8. assess • ; • , • ;
Exceptions: • • • • 6 .' • • • • •••• •••• ••• •• •
•
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. • •
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Buildin'g:Mde, Resiri!entiaV • • • • •
•• •• •••• ••••••
❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to lirV4 gi& Wkage . • •
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an it leak.Ve rate pot *see:*
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differentia All recessed • • • • • •
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ; . • :.. • •
SECTION R403 SYSTEMS ' •
R403.1 Controls.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shell be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1, Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 Inch w.g. (25 Pa) across the system, Including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑R403.4 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105"F (41"C)
or below 55"F (13°C) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulagpntsy$fefris.shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with §eotion R403'5.1 2:1o,r
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily,ac�of ,
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a arorlt�tion Rugtp!�Ifhe sysfem rett ih
❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon dreulatidn systems shall be prdhibited .
Controls for circulating hot water system pumps shall start the pump based on the identificat(on of a demand forhot water within tile:
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is A16 deslred-temperatu4and
when there is no demand for hot water.44
= '
r :c
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or W.1'575. Con s for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water tempere�� •in tft4, �lp�n� in, aejrdange
with the times when heated water is used in the occupancy., �1
d�A�10If1lIlt;ll't�"�
9/12/2018 12:11 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'% Inches (89 mm) in the hot water distribution line and cold water line located as close as possible,
to the storage tank. :**so*
R403.5.6 Water heater efficiencies (Mandatory). so 0
Ei
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic tempenakwo eontrols capable
• • • • •
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The min" topiperature •
• •
setting range shall be from 100°F to 140°F (38°C to 60°C). 0000 0000
• • • •
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit ttie power supplied o 0
0 00 0 •
••••
electric service systems to be fumed off. A separate valve shall be provided to permit the energy supplied td th$* bumgE(se
0 e
combustion types of service water -heating systems to be turned off. • • • •
• • • ••; •
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for tAe type of equipleatar6alled.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirel�entsfcr the apt mpriate
; .... ;
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. • • • & • • 0.0
• •
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be Installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other,factors that
affect equipment sizing. System sizing calculations shall not Include loads created by local intermittent mechahI8 verttilat(orn'such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment; tAall havWr('dffici6ncy',,,
rating equal to or greater than the minimum required by federal law for the geographic location where e�uament is Installdd`> °Orf
TABLE R403.6.1 V\G E NSF
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFL U'RA L?AX MU
A- (CFM)*
Range hoods
Any
2.8 cfm/watt
4WE 4F
Incline fan
Any
2.8 arm/watt
Bathroom, utility room
10
1.4 dm/watt
�°�'jr°Jcite
Bathroom, utility room
90
2.8 cfm/watt
vafr/1(iyfllll10%, O
For SI: 1 arm = 28.3 Umin. a. When tested in accordance with HVI Standard 916
9/121201812:11 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity Is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load. 0 0 "'
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment si2jp9lMJnufactujer's
expanded performance data shall be used to select doling -only equipment. This selection shall be based on the outdoor design 40y6uib
•
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFWaraSde'ii by the'expanded
•
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb teh1dbt'9ture. •
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity dsed for the load • •
• • • • •
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. •. • • • • • • •
00000
Exceptions: " " • " •
• • • • • •
1. Attached single- and multiple -family residential equipment sizing may be selected so that its ciolln; capacity is less than the
* •
•.: •
calculated total sensible load but not less than 80 percent of that load. ' :...0.
•
• •
2. • •
When signed and sealed by a Florida -registered engineer, in attached single- and multiple-farflly VAits?,the cspgS )V of
• • ";
equipment may be sized in accordance with good design practice. • • •
R403.7.1.2 Heating equipment capacity. •
❑
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and Ice system controls (Mandatory) Snow- and Ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50"F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8"C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance'aWthiY'. f�
section. L�",+
Exceptions: Q�
1. Where public health standards require 24-hour pump operation. ���•'��C,ENSF
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.-
3. Where pumps are powered exclusively from on -site renewable generation. No • 675 .1 4
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at ; "T •'-
❑ the water surface or a liquid cover or other means proven to reduce heat loss. - ;
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from sits-[4cove�d w'
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall'not Be required fl.
❑ R403.10.4 Gas- and oilfired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minirimugthehneP RED
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21:56.'Pod� ��, V
heaters fired by natural or LP gas shall not have continuously burning pilot lights. 'r�' 0 ON A"Iftsfifill; „t`.,t���
9/12/2018 12:11 PM EnergyGaugeO USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this %tandarrd. • • • • •
R403.11 Portable spas (Mandator9)he energy consumption of electric -powered portable spas shall be controlled by the• • • : • •
•••.•
requirements of APSP-14. • . • • • • ••
•
SECTION R404 • • • • • • •
ELECTRICAL POWER AND LIGHTING SYSTEMS 000000 , • •
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fiAl;pp%hall be •; • •'
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-effic icy.ap
.ps. •
Exception: Low -voltage lighting. • • •
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. ; • • • "
��tggqiFrlt4sdl�,y�fd
�oPNO GONZq�`�°>,
s.
N0. 67574
-fl ' S rATE OF �-
9/12/2018 12:11 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: REMODELING @ 138 NE 109th St Builder Name: • • : • •
• • •
Street: 138 NE 109th St Permit Office: • • • : • •
•
City, State, Zip: MIAMI SHORES, FL, Permit Number. • • • • • • •
•j•
Owner: Jurisdiction: 231000 ...;.. •
W
''
Design Location: FL, Miami .... . • ..
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTAMATICIN eA TERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insul#Wp oll .
•
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a seplingln4terial.
: :
•
Breaks or joints In the air barrier shall be sealed.
• • • •
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dapped ceiling/aaffit•
•
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overiapping joints taped.
shall be permanently attached to the crawispace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
9s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be,cut neatly'to fit'around wiring
and plumbing in exterior1Walls; got insulation.that on
installation readily cb►lfoifns to avallble`£pacg shall
i
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior wails adjacent to showers acid tubs shall%;
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated. 1
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
A
arC` ' F�
be sealed to the sub -floor or drywall.
, • n
Concealed
When required to be sealed, concealed fire sprinklers shall only be
!'•>� eS
sprinklers
a manner that is mende d by the manufa turer.ds
seaCaullekding
a\,�a
s''�NAi E, ``'\
or other adhesive sein
alants not be used fill
between fire sprinkler cover Mates and walls or cailmnos.
Illltl9
a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400.
9/12/2018 12:11 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: 231000
Permit #: a •. • •
•• • •
.••••• •
Job Information ..•;•. .
Builder: Community: Lot: ,p,.. .... •
L•:•.: : •••.
Address: 138 NE 109th St .. . • . • • •
•.•••• .
City: MIAMI SHORES State: FL Zip: : • .
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ER1 Atthod • • •
• w •
OPRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2.
O PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub -section ACH50.
ACH(50) specked on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): 4.015
x 60 + 13450 Method for calculating building volume:
CFM(50) Building Volume ACH(50)
Q Retrieved from architectural plans
F-1 PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be dosed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if Installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
9/12/2018 12:12:13 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Residential System Sizing Calculation
Summary •
Project Title: . • • •
138 NE 109th St REMODELING @ 138 NE 109th St •• • •
MIAMI SHORES, FIL ••••••
• • 44 12/2018 •
Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(? ft.) Temp Ran e"s
0000
Humidity data: Interior RH 50%
Outdoor
wet bulb 77F Humidity difference 56 r. *00006
. ..
Winter design temperature(TMY3 99%) 49
F
Summer design temperature(TMY
%%) 92
•••
Winter setpoint
70
F
Summer setpoint :
• • : • e 75
F •
Winter temperature difference
21
F
Summer temperature difference
17
f•
Total heating load calculation
23889
Btuh
Total cooling load calculation
8 974 $tuh
Submitted heating capacity
% of talc
Btuh
Submitted cooling capacity
• % of calc
ptaq •
Total (Electric Strip Heat)
142.3
34000
Sensible (SHR = 0.75)
111.0
•
344125
Latent
104.5
10375
Total
109.3
41500
WINTER CALCULATIONS
Winter Heatina Load (for 1345 soft
Load component
Load
Window total
139
sqft
3296
Btuh
Wall total
1288
sqft
7075
Btuh
Door total
63
sqft
609
Btuh
Ceiling total
1345
sqft
2478
Btuh
Floor total
1345
sqft
4163
Btuh
Infiltration
92
cfm
2123
Btuh
Duct loss
4146
Btuh
Subtotal
23889
Stuh
Ventilation
0
cfm
0
Btuh
TOTAL HEAT LOSS
23889
Btuh
VYells(29.6R)
Floors(17.4SS)
SUMMER CALCULATIONS
Window total
139
sqft
5324
Btuh
Wall total
1288
sqft
6786
Btuh
Door total
63
sqft
605
Btuh
Ceiling total
1345
sqft
3657
Btuh
Floor total
0
Btuh
Infiltration
155
cfm
2892
Btuh
Internal gain
5150
Btuh
Duct gain
3633
Btuh
Sens. Ventilation
0
cfm
0
Btuh
Blower Load
0
Btuh
Total sensible gain
28047
Btuh
Latent gain(ducts)
1289
Btuh
Latent gain(infiltration)
5889
Btuh
Latent gain(ventilation)
0
Btuh
Latent gain(intemal/occupants/other)
2750
Btuh
Total latent gain
9928
Stuh
TATAI 14PAT PAIN
3797A
Rtuh
WL
�tY
MN lwwp-I
Walls(17.9°h)
Qoors(t.b%} A
EnergyGauge® / USRCZB v6.0
Ceilings(100l6)
hk
Ductsl17.4%)
I nfi 1. v
8.9%)
Ceilings(9.5°.5j
windows(14.0%)
Latent int(7.2%)