Loading...
FW-20-9Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Permit NO.: FW-01-20-9 G r —»- ,"r �} Permit Type: Fence/Wall Work Class ificatfon: Ornamental/Metal Permit Status: Approved Issue Date: 01/21/2020 L Expiration: 07/20/2020 Parcel Number 955 NE 92ND ST, Miami Shores, FL 33138 1132060060050 Contacts ERIC FLECHET Owner 955 NE 92 ST, MIAMI SHORES, FL 33138 ARTEMISA FENCE & ORNAMENTAL INC Contractor EDUARDO VALDES Business: 3052210214 Other:3059702199 Description: INSTALLING METAL FENCE, SELF CLOSING GATES Valuation: $ 2,600.00 Inspection Requests:Inspect 4949 TotalSq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $1.80 DBPR Fee $2.37 DCA Fee $2.00 Education Surcharge $0.60 Planning and Zoning Review Fee $35.00 Scanning Fee $15.00 Structural Review ($45) $45.00 Technology Fee $3.95 Wire and Wood Fence Fee $108.00 Total: $263.72 Payments Date Paid Amt Paid Total Fees $263.72 Check # 1976 01/21/2020 $213.72 Check # 1932 01/03/2020 $50.00 Amount Due: $0.00 h Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAV I I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating con nd zoning. Futhermore, I authorize the above named contractor to do the work stated. s u a - RC6 ( �('�?O( ce Ild 1 1 "570 Authorized ign tub : Owner / Applicant / Contractor / Agent Date January 21, 2020 Page 2 of 2 Miami Shores Village 1 1 1�_ T dy VsT1 z jl BUILDING PERMIT APPLICATION Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 .BAN 0 3 2020 FBC 201-' Lotv' Master Permit No. FW- QI — 2.0 "� Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [:]RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF [:]CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: qJ 5 A] e SL 5+ _ City: Miami Shores County: �� Miami Dade Zip: Folio/Parcel#: — 3;�0(D'CC(,i'CQ S0 Is the Bui4nj Historically Designated: Yes NO Occupancy Type: Load: Construction Type: � lood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): CLL (i( -1'� p,��Q,� t ID it done#: Address: y n `"I-55 K � .9 � `�-1 Q City: I V\m '5'1^yC_K > State: Zip: Tenant/Lessee Name: Phone#: Email CONTRACTOR: Company Name: A Phone#: Address: AM( E!�3 A-✓_ City: State: Zip:�(� Quall State Certification or Registration #: Certificate of Competency #: (9 DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: 1 � 1 Value of Work for this Permit: $ at (000 Square/Linear Footage of Work: 1 )c _` Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Specify color of color thru tile: Submittal Fee $ G Permit Fee $ CCF $ 0 CO/CC $ Scanning Fee $ I5•oo Radon Fee $ `• W DBPR $ Z • a;1* Notary $ Technology Fee $ 3. 1 5 Training/Education Fee $ 0- LO 0 Double Fee $ 10 Structural Reviews $ :►qn n 1 A8•. 36 (Revised02/24/2014) Bond $ TOTAL FEE NOW DUE $ I �. Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be a proved and a reinspection fee will be charged. Y Signature Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this 3 day of 6el- 20 ( C by AE �OL , who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print:_4-1 1�. � MARLENt VALVU Seal: ��; Notary Public - State of Florida 1 Commission N GG 204098 My Comm. Expires Apr S. 2022 6ended through National Notary �s "• i *********** APPROVED BY (Revised02/24/2014) *********** The foregoing instrument was acknowledged before me this �II day of G''ew/ 20 (c by t 9 �LfJ who is personally known to as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: G / Print: Zvi E `f• Notary Public - State of Florida Seal: 1• •' e`' Commission N GG 218945 orr� ," My Comm. Expires May 16. 1022 Bonded through National Notary Assn. ` Plans Examiner ` Zoning Structural Review Clerk OFFICE OF PROPERTY A Summary Report Property Information Folio: 11-3206-006-0050 955 NE 92 ST Property Address: Miami Shores, FL 33138-2910 ERIC FLECHET &W Owner MARIA EUGENIA SPAGNOLI 955 NE 92 ST Mailing Address MIAMI SHORES, FL 33138-2910 PA Primary Zone _ 0900 SGL FAMILY - 1901-2100 SQ .........._....... .... ............ ...... __......... .._..... __. . _ _ .._.. 0101 RESIDENTIAL - SINGLE Primary Land Use FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 _....._._............................ ......_._.__._...................... ................. __......................._ Living Units 1 Actual Area 1,997 Sq.Ft Living Area 1,598 Sq.Ft Adjusted Area 1,781 Sq.Ft Lot Size 14,000 Sq.Ft Year Built 1954 Assessment Information Year 2019 2018 2017 Land Value $377,775 $377,775 $377,775 Building Value XF Value _..._..__ _. ............. ._._ _ .. Market Value $123,958 $19,567 _. $521,300 $123,958 $19,737 ..... _..._ $521,470 $123,958 $19,907 _.. ....... $521,640 Assessed Value $521,300 $521,470 $422,898 Benefits Information Benefit Type 2019 2018 2017 _....__._.__._..... _....... __...._.............._._._.._.__.............._..._.._............_ .......... _...................__-, ...__._._............ Non -Homestead Cap Assessment Reduction 1 $98,742 Homestead Exemption $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description GOLDEN GATE PK AMD PB 7-54 LOTS 5&6 LOT SIZE 100.000 X 140 OR 19829-0724 08 2001 1 COC 25923-2321 08 2007 1 Generated On : 12/23/2019 Taxable Value Information 2019 2018 2017 County Exemption Value $50,000 $50,000 $0 Taxable Value 1 $471,300 $471,470 $422,898 School Board __........ _..... ... ._._............ ._....... ..._ ............._ Exemption Value ._..__.._..................._................._._.. $25,000 ........ _.......__..._. $25,000 _.._.__.______ ..0.. $0 Taxable Value $496,300 $496,470 $521,640 City ........... _...... _............_. ._.._._.._._.........__....._....._...__...._._ _..._._.._.._.._._................._.... Exemption Value $50,000 $50,000 $0 Taxable Value 1 $471,300 $471,470 $422,898 Regional Exemption Value $50,000 $50,000 $0 Taxable Value $471,300 $471,470 $422,898 Sales Information Previous Sale 08/01/2007 Price $555,000 OR Book -Page 25923-2321 Qualification Description Sales which are qualified 08/01/2001 $247,000 19829-0724 Sales which are qualified 06/01/2000 $210,000 19250-4069 Sales which are qualified 11/01/1998 $173,000 _ 18361-291 Sales which are qualified -' The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: MIAM1•MIAMI-DADE COUNTY DADE CONSTRUCTION LIEN LAW FOR OWNERS NOTE: IF YOU SIGNED AS THE OWNER'S AGENT YOU ARE RESPONSIBLE FOR DELIVERING THIS INFORMATION SHEET TO THE OWNER OF THE PROPERTY. WARNING TO OWNER Florida's Construction Lien Low (Chapter 713, Part One, Florida Statutes) requires the recording with the Clerk of the Courts a Notice of Commencement for real property improvements greater than $2,500.00, However, it does not apply to the repair or replacement of an existing heating or air conditioning system less than $7,500.00 in value. This notice must be signed by you, the property owner. Under Florida law, those who work on your property or provide materials and are not paid, have a right to enforce their claim for payment against your property. This claim is known as a construction lien. YOU MUST FILE A NOTICE OF COMMENCEMENT For your protection under the Construction Lien Law and to avoid the possibility of paying twice for improvements to real property, you must record a Notice of Commencement in the Clerk of the Court's Office. You also must provide a certified copy of the recorded document at the construction site. The Notice of Commencement must be signed by you, the owner contracting the improvements, and not by your agent. The Notice of Commencement form, provided with this information packet, must be completed and recorded within 90 days before starting the work. A copy of the payment bond, if any is required by you and purchased by the contractor, must be attached as part of the Notice of Commencement when recorded. If improvements described in the Notice of Commencement are not actually started within 90 days after the recording of the Notice, a new Notice of Commencement must be recorded. You lose your protection under the Construction Lien law if the payments are made to the contractor after the expiration of the Notice of Commencement. The Notice is good for one year after the recording date or up to the date specified under item nine of the form. Florida law requires the Department of Regulatory and Economic Resources to be a second source of information concerning the improvements made on real property. The Building Permit Application (included with this packet) has been expanded to include information on the construction lender and the contractor's surety, if any. The new application requires your signature or your agent's, to inform you of the Construction Lien Law. YOU MUST POST THE NOTICE OF COMMENCEMENT AT THE JOB SITE By law, the Department of Regulatory and Economic Resources is required to verify at the first inspection, after the building permit is issued, that a certified copy of the recorded Notice of Commencement, with attached bonds if any, is posted at the construction site. Failure to show the inspector a certified copy of the recorded Notice will result in a disapproved inspection, (Florida Statute 713.135(1)(d)). NOTICE TO OWNER FROM SUBCONTRACTORS AND SUPPLIERS You may receive a Notice to Owner from subcontractors and material suppliers. This notice advises you that the sender is providing services or materials. Subcontractors and suppliers must serve a Notice to Owner within 45 days of commencing work to preserve their ability to lien your property. If your address changes from that given in the Notice of Commencement, you should record a corrected Notice reflecting your current address. This is done to help ensure you will receive all notices. RELEASE FROM LIEN FROM CONTRACTOR Prior to paying the contractor, you need to receive a Release of lien and Affidavit to the extent of payment from the general contractor. The Release of lien and Affidavit shall state either that all the subcontractors and suppliers have been paid or list those unpaid and the amount owed. The contractor is required to list on the Release of Lien and Affidavit any subcontractor or supplier that has not been paid. That amount may be withheld From the contractor's pay and paid directly to the subcontractor or suppliers after 10 days written notice to the contractor. If the balance due to the contractor is not sufficient to pay in full all subcontractors and suppliers listed on the contractor's affidavit, you may wish to consult an attorney. The general contractor shall furnish a final Release of Lien and Affidavit to the owner indicating all subcontractors and suppliers have been paid at the time he requests final payment. You can rely on the affidavit in making final payment to the general contractor. If you make final payment to the general contractor without obtaining the affidavit, your property can be liened for non-payment if the general contractor fails to pay the subcontractors or suppliers. You should always obtain a Release of Lien and Affidavit from the contractor to the extent of any payments being made. RELY ON YOUR LENDER FOR COMPLIANCE WITH CONSTRUCTION LIEN LAW If you have a lender, you may rely on the lender to handle the recording of the Notice of Commencement. Learn more about the Construction Lien Law by contacting an attorney, your lender, or the Florida Department of Agricultural and Consumer Services, Division of Consumer Services. Documents are recorded at the Clerk of the Courts, MIAMI-DADE COUNTY RECORDER, COURTHOUSE EAST, 22 N.W. First Street, 1 st Floor, Miami, FL 33128. You can record the Notice of Commencement by mail. The original Notice should be sent to the County Recorder, P.O. Box 011711, Flagler Station, Miami, Florida 33101. Please make sure the original Notice is signed and notarized. Also, remember to enclose the recording fee (for a single copy) and written instructions for recording and returning a certified copy of the recorded documents. For additional information on fees and recording documents call (305) 275.1 155. 120_01-52 PAOE08/12 tA& WHAT FlP In' I01.arR/MISOXM r1P 117 /// LOT L. I LOTS -'y'C -•E- Ell cD'l 8 12.$P LOI1C. ,. ; i 1 _ � ac srom K61CMK11955 �} � 94 0.0 - - 'Ti 25 ;2i CONE. 00 •GR/DO ... •" 14.75' 2.0fl'•: 1340 ' PIANTFK BarlDW, 27415W) FlP In -� h1�-- y r,P In' I 100.( tP) 100,11W) NO D UP A51`rWLT ROAD NE 92nd STREET = GOLDEN GATE QUA t% p 50.00 TOTAL WW GRAPHIC SCALE 0 15 10 1 RLS 0: 07-07-M iE CLIENTN: 1078-1682465 ADDRES\ S �+ FIELD DATE: 07-09-117 955 NE 92nd Street DRAFTER: E'V Miami Shores, FI 33138 APPROVED: AS i LEGAL DESCRIPTION: (AS FURNISHED) SCALE: 1' - 30' �J Lot 5 and 6 of AMENDED PLAT OF GOLDEN GATE PARK, acmrdalp tO the Plat [tN: W AS Lrsnlded In PUt SO& 7• page 54 M the Kok Raox& of MIatN Dade Cb mty, Florida. BASIS OF BEARINGS: N4 . LIST OF POSSIBLE ENCROACHMENTS: F—aD . E.Aelty Properb Lft- LandTech R V E Y 1 N G I'Ledfq TaE . taaN Led 9rr.rytq SNUL, Pod• xably bettor! -' './<- SeeMyNeW me! ,SLCNW{MSraR51t5h rotlademk,rMm7J%% First Arnvric.m or.M4ITWO F¢P95q M4W Title InSurinrr Cinnp<tr>_y FI NutABE : a0r .__._ 1�•CY° '-:. :. �w ow rnct.rwwrtn � � � xCt Upy1G OVIF K.0 CNIt AAf: LtxUr4 «NCNL ttCOFnteOfx s+ . Cxnw SURVEYOR'S CERTIFICATE _ Ifermrl Ov the 1G 37-6, tWft I Iweby LVf R W the ore F de As for bM wn yr M FbrNt b s<I lath N Oylprn 61G 17-6 MMe ,e. axa. tw aww+et. eetlb Ye Nw aw PnAfwb�eon CERTWED TO: (Ae FTIiWI•NEO ELlo F'kthel aM Manor 6 _.. U9—spa9r h t . CLMM u4 K . r«n «< rvuwL CI = Onnr[O fad.n�0 Mn34T[ FCG pFa«CUMWW CWvnNeE edmMtgr+tiq mde. PuaaPc la QbDar 1)2.0]7, ftrY4 8mute. �f$ Rr4 A —an TNC lrnurancr CanpOny CR ..wfu.LnonoNttcoaD onr. M[O EnVJNxµ FOF.a.a «et«we �.p.N .tr' NIu. SA �, ri Olpeal Matgaye SNIA1orL5• LLC —12 ryaul roeFO.n«COwMxclMLrt �7QVpY'' �4 « oaw,.wttMtwtxL .x. tMuaw n�rO�.nanAr�aL�xLLYvrvnnm tow-m«aw.Lu 'ya^'F - saaav ": N waxroRoa .R'n"iL wNi+nn .xawUtr Zt uF UM1'CwSCNUn IR-NAAoaOxw - LN . L0114xw. yF .urUrr� l .MLfUw nOCMaOr, S • ��ff / / '. Tate aT A \ p,•mN ! NOYES� nAe alAMvrYM,1NNEUWIrxWrMKKI1r«A y--'-'f t. uxnfP0rUlAn Urury weTAWrO6. WDFnUPaAO • � SbtwL'/Q� iY1 F['Sa SYtTN�-_..•-.... __._.___--.- wrwo.[wne.ra.n.rwwaAwioEarLaurmmAallo FnR wFafuutrowAL Pt.Po'OSEs otly lLncAftOw h PrLOPERT'a11aeN NERlDN IRIAAaro _.._........-__-...-_-__ flRM _ arxuLlUEa HERE LOrIOCArte av rx•+ULMY xUIPAM«W:rEa U°ER1eeE. NL PIOFERfv FLOD03UNE'a', MEA«MwWtI FLODgeU.RAF.IAN. SUR R'S NAME DATED: 07.09-07 cavum •Lo.wwwewLIM,II Etmrwmr .. M rWp1F tr Twa wAen!r a wRL•t w ANn rAaaafwsss owaawrAnl•DN Mfeannew. +xn TIRLEI'DR NAAesxo WAPANIEfa M ro M rccwAcr« oerwxwo lrrtt wnunrxcE wm twNtcw nE Aoolc wroPLL�1gN.nE LOcn FEarw AOExr•nuoeE MffD Pon y[AECA}Atrl._-.......__.....-.— NOT VALID WITHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE w10 a+aAO Mf of IIAFa fM aYN10Kigx wYNUaFA RESIDENTIAL FOR ALL INOWRESCONTACT: RLs. WC. AND AUTHENTICATED ELECTRONIC SEAL T1a5EVRVEYSPREPMEDFDRTE £ACLAleLL'E 115E DATE REVISION DATE .-.____.. _... REVI910N Arm leN m OF THE PARIIESZEDNEReON- LWI l TO TOLD PAmas wY ml eE r IANIa SRitl'I[:E5. rvr IhtuYF*h+naw.cu^+ TRANaFEAAWORASLDNEO. kc6,o'1 It051)O1.1t00 arm a.7R R®viewed & Accepted by: _ Data ...........� t ._-----.._ ._.� Date FLORIDA METAL PANELS CR NNI& NOM. 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2017. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPLICABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5. CONTRACTOR IS TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPLIED BY THE CLIENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CLIENT CONFIRMED DESIGN AND DIMENSIONS. ADDITIONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDITIONAL COST. 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER. 16. EASTERN ENGINEERING GROUP SHALL NOT BE LEGALLY RESPONSIBLE FOR THE STRUCTURAL DESIGN OF ANY COMPONENT AND/OR PRODUCT USED IN OUR PROJECTS WHICH HAS BEEN PREVIOUSLY GRANTED A PATENT OR COPYRIGHT. THE CONFIRMATION OF INTELLECTUAL PROPERTY OWNERSHIP IS BEYOND OUR SCOPE AS STRUCTURAL ENGINEERS AND SHALL BE THE SOLE RESPONSIBILITY OF OUR CLIENT. DESIGN LOADS FENCE WIND LOAD AS PER ASCE 7-10 KD=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 - - - - - - 115 mph (AS PER FBC 2017 SECTION 1616.2.1) CALCULATIONS i accordance with FBC 2017 and ASCE 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE ASTM GRADE Fy STEEL SHEETS A36 - - - - - 36 KSI STRUCTURAL TUBING A500 B 46 KSI 3. ALL STEEL SHALL BE HOT -DEEP GALVANIZED. 4. PAINT STEEL HOT GALVANIZED SURFACES IN CONTACT WITH CONCRETE WITH ALKALI -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER '-_ __ __ __. _... ................. ace.. �r va_uc a•M�� Category: I L (ft): 4 2 1/2x2 1/2x16Ga. Steel C. Exposure: C Hpost (ft) 6 A-500 V (mph). 115.00 m) 139 I: 1.00 -500 Fb (psi) 27600 Zx (n^3)b Kd: Fv (psi) 18400 fb (psi) Mmax/Sx h (ft): 6 ..m Fy (psi) 36000 fb (psi) 24132 Pd (psf): 16.2 A-36;Fb (psi) 21600 fb (psi)<Fb OK _. Fv (psi) 14400 Rail to Posts Connection Design ,Foundation Design (nonce Actual Pullout 194.4i 'P 388.80 Allowable Pullout 200 Using 10 16 Hilti Kwik q............. 1.44 OK Flex Screw d 3.00 Top and Bottom Design 2xlx16Ga. Stl Galvanized A-500 Mmax. (lb -in) 1166 Sx (in^3) 0.124 fb (psi) Mmax/Sx fb (psi) 9406 451613 fb (psi)<Fb OK Lateral soil bearing; 200 Footing Diameter (ft) 1.583 For poles 1806.3.4 , 2 TYP. FENCE PLAN VIEW SCALE: 3/4"=1 '-O" M II � I II II I �I I I I II � II II II II II II II II i ! II I FENCE CONNECTIONS: \\/ - RAIL TO POSTS TO BE CONNECTED WITH (2) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL. ACCESS HOLE AT RAILS TO BE PROVIDED FOR CONNECTION, OR N I I BE A" WELD 1 " WELD LENGTH IN 2 OPOSITE SIDES MINIMUM. - PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WITH (4 PER PICKET (MIN), 2 TOP & 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL, U OR BY 1/4" PUDDLE WELDS. U TYP. FENCE ELEV. VIEW SCALE: 3/4"=l'-O" i Cq S=0.47 IN' Z=0.58 IN' Mmax=16.2*4*6*6/2 =13 997 #-in M ASD=M n/R , Mn=Fy*Z , R =1.67 M ASD=16 000 #-in Mmax < M AsD S=0.124 IN' M max=16.2*6*.5*4*4/8 =1 166 #-in M Aso=Mn/0 , Mn=Fy*S , 0 =1.67 M ASD=2 673 #-in Mmax < M Aso I, 2" I. RAILS (16 GA) 2xlx16 G j GALVANIZE STEEL TU RAIL TOP MEMBER 26 GA IN.) GALVA METAL 2.5x2.5x16 GA. GALVANIZED STEEL POST SPACED 4'-0" MAX. O.C. 2xlx16 GA Ct GALVANIZED - STEEL TUBE > RAIL BOT. MEMBER i O �I 0 LU 3000 PSI CON ET FOOTING 012"x '-0 4 DEEP OR 019" Q DEEP OR 024" '- DEEP (TYP) ONLY FOR SEDIMENTAW AND FOLIATED ROCK SOILS 012"x2'-9" DEEP (*) (*) SOIL SHALL BE VERIFIED TO BE CONSISTENT WITH THE MENTIONED CHARACTERISTICS. A FLORIDA LICENSED ENGINEER SHALL VISUALLY INSPECT AND PROVIDE A CERTIFIED LETTER ATTESTING SO. Zx=0.0054 in' Mmax=16.2*(6/12)**0.5*1.33*1.33*12 Mmax=86.0 #-in M ASD=Mn/R , Mn=Fy*Z 4 =1.67 M LSD=116.4 #-in 00 Mmax < M Aso 6" CD to O O p O N PICKETS (26 GA) O ~9 _-W a saw x _C ❑RAISSA R. LOPEZ,PE ❑GONZALO A. PAZ,PE 9 SD-1 BE AT NO MORE THAN 4' 3'-0"/4'-0" MAX BE AT NO MORE THAN 4' FLORIDA METAL PANELS CERIUM& NOM& 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2017. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPLICABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5.CONTRACTOR IS TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8.THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPLIED BY THE CLIENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CLIENT CONFIRMED DESIGN AND DIMENSIONS. ADDITIONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDITIONAL COST. 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER. 16. EASTERN ENGINEERING GROUP SHALL NOT BE LEGALLY RESPONSIBLE FOR THE STRUCTURAL DESIGN OF ANY COMPONENT AND/OR PRODUCT USED IN OUR PROJECTS WHICH HAS BEEN PREVIOUSLY GRANTED A PATENT OR COPYRIGHT. THE CONFIRMATION OF INTELLECTUAL PROPERTY OWNERSHIP IS BEYOND OUR SCOPE AS STRUCTURAL ENGINEERS AND SHALL BE THE SOLE RESPONSIBILITY OF OUR CLIENT. DESIGN LOADS FENCE WIND LOAD AS PER ASCE 7-10 K D=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 - - - - - - 115 mph (AS PER FBC 2017 SECTION 1616.2.1) 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE ASTM GRADE Fy STEEL SHEETS A36 - - - - - 36 KSI STRUCTURAL TUBING A500 B 46 KSI 3. ALL STEEL SHALL BE HOT -DEEP GALVANIZED. 4. PAINT STEEL HOT GALVANIZED SURFACES IN CONTACT WITH CONCRETE WITH ALKALI -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER CALCULATIONS In accordance with FBC 2017 and ASCE 7 10. _ _ _. ...._. Wind Speed from FBC 2017, Chapter 16, Section 1616.2.1 v=115 mph . Wind load Calculation: General Data: DL(psf): 5 Top and Bottom Design V (mph): 115.00 Fence Span(ft): 4 Gate Span(ft): 4 ;(Gate Span - Gate Leaf, not opening) 2xlxO.071 st galvanized Exposure: C Hpost (ft) 6 Post Design ( A-500 Gust Factor 0.85 Fy (psi) 46000 Steel galvanized AS00 Mmax. (lb -in) 2608 Cf. 1.30 A-500 Fb (psi) 27545 Section M ^ ^3) 0.124 wind,_ MDR Mmax. (lb -in) Zx (in 3) fb (psi) Sx (in _ . Kd: a0;85 Fv (psi) 18400 2.5x2 Sx16Ga 14012 2880 14305 0.58 24663..7 fb (psi) Mmax/Sx' In (ft): 6.00 Fy (Psi) 36000 fb (psi) 21029.6 1 Kz: 0.85 A-36 Fb (psi).. 216CO fb (psi)<Fb OK .......,,._... ... fb (PSI)<Fb OK qz (psf): 16.2 Fv (psi) 14400 Rail to Posts Connection Design Foundation Design (nonconstrained FBC 2017-1807.3.2.1) (2017-1806.2) Actual Pullout 32 P 583.83 Lateral soil bearing 200' Allowable Pullou 200 Using 10-16 Hilti Kwik A _ 2.16 Footing Diameter (ft) 1.58333 OK Flex Screw d (Depth) 395 For poles 1806.3 2 2x1x16 GA. GALVANIZED STEEL FRAME GATE (NP) i GALVANIZED STEEL POST 2-1/2"x2-1/2"x16GA 26 GA. (MIN.) GALVANIZED METAL SHEET DURA FENCE a I 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) HINGES TO RESIST 180 LBS 2x1x16 GA. GALVANIZED STEEL FRAME GATE C, (NP) -1 GATE CONNECTIONS: - PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WITH (4 PER PICKET (MIN), 2 TOP & 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL TYP. SINGLE GATE ELEV. VIEW SCALE: 3/4"=1'-O" r I 2-1/2"x2-1/2"x16GA TYP. SINGLE GATE PLAN. VIEW SCALE: 3/4"=l'-O" S=0.47 IN' Z=0.58 IN' Mmax=14 305 #-in M ASD=Mn/4 , Mn=Fy*Z , 0 =1.67 M ASD=16 000 #-in Mmax < M Aso rv_� 1 3 k 1 o urn,) S=0.124 IN' Mmax=2608 #-in M ASD=Mn/R , Mn=Fy*S , 0 =1.67 M ASD=2 673 #-in Mmax < M ASD L 2" RAILS (16 GA) 0 I i� 3 KSI CONC! "It 012"x4'-O" D5EW.GR. 019"x3'-O" DW.QR 024"x2'-6" DEEP ('fF) ••••.• APPLICABLE WL EW1 ONLY FOR S dT R_YY AND FOUATER ROCK • SOILS • • 0 012"x2'-9" BEEP I • �• _ N - ALL GATE FRAMES TO BE CONNECTED BY ALL AROUND FILLET WELD. (*) SOIL SHALL BE VERIFIED TO BE CONSISTENT WITH THE MENTIONED CHARACTERISTICS. A FLORIDA LICENSED ENGINEER SHALL VISUALLY INSPECT AND PROVIDE A CERTIFIED V-j, 1133 Q. Z) ON M � a ��2 � Q, N M u- Lu �o V 03 o, W��O •• ¢ • •• • ui z q�'•• � w • so 4 ' ^ M a •••s•• • • so • *see* oo •• LLI e U� •-�••a• • • •Z • LL) O i c • LL.•�. see.•ama- � OJD x� - ILL. Zx=0.0054 in' Mmax=16.2* (6/ 12)*0.125*2.6*2.6* 12 Mmax=83.0 #-in M ASD=Mn/0 , Mn=Fy*Z , A =1.67 M ASD=116.4 #-in 00 Mmax < M Aso 6" O r`� O O p O N O PICKETS (26 GA) Ref. Paae # 19-0247 o w o ❑RAISSA R. LOPEZ,PE ❑GONZALO A. PAZ,PE k/s/zol9 =,A s FLORIDA METAL PANELS , 1. ALL WORK V SHALL CONFORM CO FORt 0FLORIDA BUILDING CODE 2017. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPLICABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5. CONTRACTOR IS TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8.THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPLIED BY THE CLIENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CLIENT CONFIRMED DESIGN AND DIMENSIONS. ADDITIONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDITIONAL COST. 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER. 16. EASTERN ENGINEERING GROUP SHALL NOT BE LEGALLY RESPONSIBLE FOR THE STRUCTURAL DESIGN OF ANY COMPONENT AND/OR PRODUCT USED IN OUR PROJECTS WHICH HAS BEEN PREVIOUSLY GRANTED A PATENT OR COPYRIGHT. THE CONFIRMATION OF INTELLECTUAL PROPERTY OWNERSHIP IS BEYOND OUR SCOPE AS STRUCTURAL ENGINEERS AND SHALL BE THE SOLE RESPONSIBIUTY OF OUR CLIENT. DESIGN LOADS FENCE WIND LOAD AS PER ASCE 7-10 KD=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 - - - - - - 115 mph 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE ASTM GRADE Fy STEEL SHEETS A36 - - - - - 36 KSI STRUCTURAL TUBING A500 B 46 KSI 3. ALL STEEL SHALL BE HOT -DEEP GALVANIZED. NEXT POST FENCE TO BE AT NO MORE THAN 4' 2x1x16 CA GALVANIZED -� STEEL FRAME GATE (TYP) .I GALVANIZED STEEL POST 2-1/2'x2-1/2- x14GA 26 GA. (MIN.) GALVANIZED METAL SHEET FENCE M HINGES TO RESIST 180 LBS 2xlxl6 GA GALVANIZED STEEL FRAME GATE (TYP) 3 KSI CONC. FOOTING 019'x4'-O" DEEP OR 024'x3'-9' DEEP OR 030'x3'-4' DEEP OR 036'x3'-0' DEEP MID) 2xlx16 GA GALVANIZED STEEL FRAME GATE (TYP) 10'-0' 2xlxl6 GA GALVANIZED STEEL FRAME GATE (TYP) 0 U ` 7/8' DIAM. SOLID BAR CANE �q BARS GATE CONNECTIONS • PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WTTH (4 PER PICKET (MIN), 2 TOP & 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL ALL GATE FRAMES TO BE CONNECTED WTTH 1/8' FILLET WELD ALL AROUND. i lr. L UBM GATE El". ♦lain SCALE: 1 /2"=1 ' -O" 1 i r. MUBIE GATE rJ.M. ♦ W SCALE: 1 /2"=1 ' -0" NEXT POST F04CE TO BE AT NO MORE THAN 4 1 V 0 • • 019J 4W0" DEEP ORG 024'x4J'sTd0EP OR • 030 4.,117 4)[EP • • OR 0 6'x '-O' DEEP (TYP APPUCABLE ENCLUSNE • nAa••inr•inll/rxRl DY • DOEP (�) SOIL ST BE !(E�i�IED TO Et CONSISTENT y�jTy J}TE I NT10NED • CHARACTERISTICS. A FLORIDA • LICENSED ENGINEER SHALL • VISUALLY INSPECT AND PROVIDE A CERTIFIED LETTER ATTESTING SO. GALVANIZED STEEL POST 2}'x2}'xl4GA 24 GA (MIN.) GALVANIZED METAL SHEET FENCE (AS PER FBC 2017 SECTION 1616.2.1) [1, rAnvl JILLL nUI bALVANILtU JUKrAUtJ IN UUNIAUI WIIH CONCRETE WITH ALKAU -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER (J CALCULATIONS S=0.124 in' � In accordance with FBC 2017 and ASCE 7-10, 0.06 Zx = 0.155 in' Zx=0.0054 in' Wind Speed from FBC 2017, Chapter 16, Section 1616.2.1 v=115 mph Mmax=4074 #-in Mmax=16.2*(6/12)*0.125*2.6*2.6*12 Wind load Calculation: General Data: DL(psf): 5 Top and Bottom Design S=0.57 in' M ASD=Mn/fl , Mmax=83.0 #-in V (mph): 115.00 Fence Span(ft): 4 Gate Span(ft): 5 (Gate Span = Gate Leaf, not opening) 2x1xO.071 st galvanized Z=0.71 in' Mn=Fy*S , 0 =1 .67 M ASD=Mn/0 , Exposure: C Hpost (ft) 6 Post Design A-500 Mmax=16 393 #-in M Aso=4269 #-in Mn=Fy*Z , 0 =1.67 Gust Factor 0.85 Fy (psi) 46000 Steel galvanized A-500 Mmax. (lb -in) 4074 M ASD=Mn/0 , Mmax < M Asu M ASD=116.4 #-in Cf: 1.30 A-500 Fb (psi) 27545 Section Mwind MDI_ Mmax. (lb -in) Zx (in"3) fb (psi) Zx (inA3) 0.155 Mn=Fy*Z , 0 =1.67 0.06 pp Mmax < M ASD Kd: 0.85 Fv (psi) 18400 2.5x2.5x14Ga 15764 4500 16393 0.71 23089.1 fb a M ASD=19550 #-in O 6 r h (ft): 16.2 Fy (psi) 36000 (psi) Mmax/Sx 00 (psi) 26287 Mmax < M ASD O Kz: 0.85 A-36 Fb (psi) 21600 fb (psi)<Fb OK fb (psi)<Fb OK O O 9z (ps`�: 16.2 Fv (psi) 14400 Rail to Posts Connection Design Foundation Design (nonconstrained FBC 2017-1807.3.2.1) (2017-1806.2) L 2 4" L 2- O Actual Pullout 32 P 583.83 Lateral soil bearing 200 N Allowable Pullou 200 Using 10 16 Hilti Kwik A 2.16 Footing Diameter (ft) 1.58333 POSTS (14 GA) RAILS (16 GA) PICKETS (26 GA) OK Flex Screw d (Depth) 3.95 For poles 1806.3 2 Ref. Page # 19-0247 11 I