Loading...
RF-20-66Permit NO.: RF-01-20-66 Miami Shores Village - Permit Type: Roof 10050 2 Ave Miami Shores FL 33138 Work Classification.- Flat 305-795-2204 Permit Status: Approved Issue Date: 01/30/2020 Expiration: 07/28/2020 Location Address Parcel Number 357 NE 97TH ST, Miami Shores, FL 33138 11320601357SO Contacts Kristy Johnson Owner TOP SEAL SERVICES CORP Contractor 35797 RONALD MEDINA Business:3052135328 kjohnson@thealdermanlawfirm.com Business: 3057547844 Description: RE -ROOF FLAT AT REAR OF HOME Valuation: $ 908.00 Inspection Requests: ti 4949 Total Sq Feet: 1,200.00 .j �1 ____ I F Fees Amount Application Fee - Other $50.00 CCF $0.60 DBPR Fee $4.13 DCA Fee $2.75 Education Surcharge $0.20 Roofing Fee $225.00 Scanning Fee $9.00 Technology Fee $6.88 Tota I : $298.56 Building Department Copy Payments Date Paid Amt Paid Total Fees $298.56 Check # 3752 01/30/2020 $298.56 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws Legulating constructigMd zoning. Futher ore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner January 30, 2020 nt / Contractor / Agent Date Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ROOFING ENTERED JAN 13 2020 BY: —6 �_:) — FBC 20 1 Master Permit No. Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE::: r 1 �FFE: y� OWNER: Name (Fee Simple Titleholder): N"1 :�J0 Phone#.N3_j7? Address: 1 "JL 7 S City: 11 11 "M I Tenant/Lesse�e/Name: Email: M `d State: fL Zip: '—'?—?>13 p Phone#: f CONTRACTOR: Com any Name: 7b Phone#: 3 Address: City: Z-�N c State: Zip: Qualifier Name: -- Y ' I VX/- Phone#: State Certification or Registration #: �C� 3? d�l Certificate of Competency #: 7- DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: 4 .1C7,� Value of Work for this Permit: $ q�-' Square/Linear Footage of Work: p.{� Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑ Demolition Description of Work: C Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ �J J (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City • 1-1 State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City , ^' State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT'*MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated -value exceeding $2500,,the applicant must promise in good faith that a copy of the notice of commencemerit'and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of comm77� ted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. 1 osted notice, the inspection will not be approve reinspection fee will be charged. �2 I:-,- Signature Signature NER or AGENT TOR The foregoing instrument ,was ,acknowledged before me this day of ``.Jo'I 20 Zy by Y151 �• J��D'n , who is ersonally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: The foregoing instrur4nt was no dged before me this 'e) day of S-p4j It 20 20 by as me or who has produced identification and NOTARY PUBLI who is personally known to . as MICHAEL MARTINEZ MY COMMISSION # GG041319 EXPIRES October 24, 2020 Sign: Sign: Print: Print: r� Troy Tolent no Seal: NOTARY PUBLIC Seal: _STATE OF FLORIDA Comm# GG233105 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Property Search Application - Miami -Dade County Page 1 of 2 OFICE OFTHE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-013-5750 357 NE 97 ST Property Address: Miami Shores, FL 33138-2405 JASON R ALDERMAN & Owner _....................... KRISTY M JOHNSON (JTRS) __.... .._._-_____.._.._..__.._... _..................... 357 NE 97 ST Mailing Address MIAMI SHORES, FL 33138-2405 PA Primary Zone ... ......... _........ _....... _............... -..... - - ---- 1000 SG FAMILY - 2101-2300 SQ --- _ 0101 RESIDENTIAL -SINGLE Primary Land Use FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 ... - ..... _-__._.._ _ -- Floors __-.-_.._._._._ 1 Living Units 1 Actual Area 2,459 Sq.Ft Living Area 1,895 Sq.Ft Adjusted Area 2,177 Sq.Ft Lot Size 8,625 Sq.Ft Year Built 1938 Assessment Information Year 2019 2018 2017 Land Value $258,854 $258,854 $258,854 Building Value $151,519 $151,519 $151,519 XF Value $2,597 $2,630 $2,663 Market Value $412,970 $413,003 $413,036 Assessed Value $314,737 $308,869 $302,517 Benefits Information Benefit Type 2019 2018 2017 Save Our Homes Assessment $98,233 $104,134 $110,519 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000 Second Exemption $25,000 $25,000 $25,000 Homestead Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 15341 65342 MIAMI SHORES SEC 1 AMD PB 10-70 LOT 18 & E1/2 LOT 17 BLK 42 LOT SIZE 75.000 X 115 OR 14391-484 0190 4 Generated On : 1/13/2020 Taxable Value Information 20191 20181 2017 ........._.... _.................... ................. __-I .._.._.__.._............. ..................... L___........_.._...................... County Exemption Value - -- $50,000 $50,000 ._ ..............-- $50,000 Taxable Value $264,737 $258,869 $252,517 School Board _ Exemption Value $25,000 $25,000 $25,000 Taxable Value _ $289,737 $283,869 $277,517 ...................... .......................... _.... ..... City Exemption Value $50,000 $50,000 $50,000 Taxable Value $264,737 Regional _....._..__ Exemption Value $50,000 Taxable Value $264,737 $258,869 - ................................_._.._................._.._..�......._..._... $50,000 $258,869 $252,517 $50,000 $252,517 Sales Information Previous OR Book - Price Qualification Description Sale Pa a 9 23745- 08/01/2005 1$650, 000 Sales which are qualified 0268 ...... -... ...... .................. ....._...................................._ 11/01/2004 1$373,000 ... ............-------.---.. 22844 _.......................... _.... _.... -_.................................. ._.........._� Sales which are qualified 0196 00000- Sales which are disqualified as a result 01/01/1990 $0 00000 of examination of the deed 12613- 07/01/1985 $100,000 Sales which are qualified 0035 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade Countv assumes no liability, see full disclaimer and User Aoreement at http://www.miamidade.aov/info/disclaimer.asD https://www8.miamidade.gov/Apps/PA/propertysearch/ 1 /13/2020 OWNER'S AFFIDAVIT OF EXEMPTION Roof to Wall Connection Hurricane Mitigation Retrofit for -- -- Existing Site -Built Single Family Residential Structures, Rev. 02d0-2= Pursuant to Section 553.844, F.S. PERMIT No: Job Address 357 Kc q- J OWNER'S INFORMATION: (Only the owner of record may submit and must sign this application.) �[ Name: c4� Address/ City / State / Zip Phone No: 3 3 —narr Email: K �stT (r�/3 ��� •� -- Dear Building Official: IklxC6 � e if that I'am not required to retrofit the Roof -to -Wall connections of my b Iding because: 0-he just valuation for the structure for purposes of ad valorem taxation is less than $300,000. El The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC). When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.01k and the building was not constructed in compliance with the FBC nor 1with 1 4 SF C, an Affidavit of Roof to Wall Connection Mitigation Retrofit must be p o Signat he Property Owner //12," Owner's Signature (Date) State of Florida ) County of Miami -Dade) yl~ Sworn to and subscribed before me this I Day of 20220. gy :rjr'%'Bk1A 1—k- SO Personally known Kor Produced Identification ( ) Type of Identification produced (SEAL) , Troy Tolentino NOTARY PUBLIC ' a -+STATE OF FLORIDA Page 1 of 1 Comm* GG233105 • iN E 1�� Expires 7/23/2022 K r Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Uff Section A (General Information) aster Permit No. PPWAM No. Name r oo M Q o o � n W ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Mortar/ eslve $et ble C Asphaltic ❑ Metal Panel/Shingles ❑ Wood`%hk g'les/Shakes Shingles • • e • • re m i U - ❑ Prescriptive BUR-RAS 150 Gas Vqq%; s? z � I a ROOF TYPE Y�sr3 ;No • z Type: Nsitur;%l❑ L. sodQ3��M ,� ❑� New Roof Re -Roofing Recovering ❑ Repair Maintagggge a I ROOF SYSTEM INFORMATION Low Slope 400f Area (SF) Steep Sloped Roof Area (SF) Total (SF) 1z Zi f Section B (Roof Plan) Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Irio..fffir elirnanstlnna of elevated nressure zones and location of parapets. ".�EECC': ' an QC long "miummu::C: E".�MI1 ■ ■ ■■#■■##■■■■ # ECCm.iC#�::Ci.'�::: ■■■■■■ MEMO ■ ■ � ' C O EC E�C■## C ' CEDE C.CpC ■ ■QQC'CQi#'C`C■■#■..■ C'CCCCC�CCCQ#■ C :#■ ■ ■i "'QCQE'Er::":E CQ■#EM ■ : E#■ ■E ECC ■ :CCCC #�#�EE ■#■M#■■ ■ :" ■C■ QCE: ' ' #■'Q ■ .. C�"in ' QQ C ' . ■' C # C .■.M Q CCCC EC C ■ C ■ �fiG' .. EEE C E: ■CCC■ #C■C a ME ■E .# C#■ ■MMMMC.■ #'�r'■C■. no IN C C■#. �'.■ # ..■ .. .# M . .■ #„ . C�pC EEMC# : ■M CE EC ■C■' EM■ M . M E ■ ■C#■■r■� �ECCC# ■... . MM C iEC: 'ECE ■M#M�r..Ci':C�■CC ': EEE.�CCC #C # CE p'##�E �CE'9M CAE EOn �. # tad . C ■#EN i #CC0i�WIN M■#0EE Q #fir' G^ ---------- ---- --- CC# �.CC 'CCC■E#u C C° 'CC■ #C■C ■ C #G■■C E:M. .■ ;onC■CC■C'#iE# C M# C #,: 'CECQ ':':#: :•. #■ESEE ;EC ■ "QE:':':. EEEEEEC■# E .'CE#CC.E.EC,I.CC�..C■C.. ''Gi'C �i'CC .■M �■MGi. �C.■ � EE C C ■CC■ #r MC .. CC.. �►• CE ■■ as ■ C . � EC : C■E .C■ C Q CC . M: ■M EE # ■C C'# C■ E MEMCC .... C ■.� ■�' Q� ■C. M E� a �r'■EC M■":.. . C; ■ . .: ■ i � C C C C Q CC':'■ ■�# �QE E 'C C �C'f EE�� M ■C IC C„ .ECCE inHIM■ : EE '�N r■ i ■C ■ CM ; i'",�' ■. '. ■ Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components and Identify Manufacturer (if a component is not used, identify as'NA') System Manufacturer. GAF MATERIALS CORP NOA No.:. 18-0919.12 Design Wind Pressures, From RAS 128 or Calculations: Pmax1: 42.8 pmax2: 71.7 pig: 108.0 !SYSTEM i1 OPTION #1 Max Design Pressure, From the Specffic NOA -45 System: Deco PLYWOOD Type: Gaugerrhickness: 5/8" MINIMUM Slope: 1 /8"• 12 Anchor/Base Sheet & No. of Ply(s):1 PLY 75# BASE Anchor/Base Sheet Fastener/Bonding Material: 12G. _NNI11 ARRUSAIANa&4 5/8"TOAl2S Insulation Base Layer. POLYISOCYANU RATE 1.0' MIN 4'X4' Base Insulation Size and Thickness: Base pr 6tgaXhWALe,perBonding Material: Top Insulation Layer. N/A Top Insulation Size and Thickness: N/A Top Insulation Fastener/Bonding Material: N/A 1 PLY PERFORATED STRATAVENT Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s).& No. of Ply(s): 1 PLY GAF RUBEROID 20 Ply Sheet Fastener/Bonding Material: HOT ASPHALT Top Ply: GAF MINERAL SURFACED CAP SHEET Top Ply Fastener/ Bonding Material: HOT ASPHALT Surfacing: N/A Fastener Spacing for Anchor/Base Sheet Attachment Field: 8 " oc @ Lap, # Rows 2 @ 8 " oc Perimeter. 6 " oc @ Lap, # Rows 4 @ 6 " oc Comer. 6 " oc @ Lap, # Rows 4 @ 6 " oc Number of Fasteners Per InswulatOn • ..•. Board • NIA •••••• • Field Perimeter CorgeC ,• Illustrate Components Noted,' ; •' • • • Details as Applicable: ...... Woodblocking, Gutter, Edge •Teri nation,'.•'.; Stripping, Flashing, Continuous .GIP.at,. Cant . Strip, Base Flashing, Countet- fl$shing,. Coping, Etc. ' • Indicate: Mean Roof Height, Pal`4p�t yeight, Height of Base Flashing, Component Material,*.,,,,* Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. GAF MINERAL SURFACED CAP SHEET FT. 0 Parapet Hei�Iht 3X3 GRIP 28 OA GALV R PERFORATED PED STRATAVENT FT,1 11 Mean PLY OOD MIN 5/8" Roof Height POLYISO MIN 1.0" 04 16 pressure treated wood blocking fastened to plywood deck with 8D RS Nails @ 6" oc staggered 119" wick strip of GAF Ruberoid 20 ROOFING SYSTEMS I UL Product iQ Page 1 of 1 20. Dec C-15/32 Incline: 1 Ba eet — One ply Tvpe G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet' mechanically fastened. Insulation (Optional): — Any thickness or combination: perlite or wood fiber or glass fiber or pol isocyanura e mechanically fastened or hot mopped or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Base Sheet: — One or more plies "RUBEROID® 20 Smooth", "Ruberoid ® 20 Plus Smooth" or "RUBEROID® HW 25 Smooth", mechanically fastened or fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapTM ineral-Surfaced Cap Sheet'. . • • • • • https://iq.ulprospector.com/en/profile?e=148955 10/30/2019 M1AM1•6ADE '81IANI1-DADS COUNTY PRODU('T CONTROL SECTION 11805 SW 26 Street. Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami. Florida 33175-2174 HOARD AND CODE _1DMINISTRATION DIVISION 'I' (786)315-2590 r (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) GAF • i Campus Drive �• • .... Parsippany. NJ 07054 . • � • � • :..... SCOPE: ...... • This NOA is being issued under the applicable rules and regulations govertung the use ot;,60:;nictio$... • • materials. The documentation submitted has been reviewed and accepted by Miami -Dade 4�nn-pty RER, Product Control Section to be used in Miami Dade County and other areas where allowetlb,%•the •• Authority Haying Jurisdiction (AHJ). • •' • • • . • • .. • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County $roduct; • • • • Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami DadeC!otuttv) • reserve the right to have this product or material tested for quality assurance purposes. If this product ore e material fails to perform in the accepted manner, the manufacturer %gill incur the expense of such testing and the AHJ may immediate]- revoke_ modify, or suspend the use of such product or material within their jurisdiction. RER resen•es the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein. and has been designed to comply xvith the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid" Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo. cite. state and following statement: "Miami -Dade Count\- Product Control Approved". unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERIMINATION of this NOA trill occur after the expiration date or if there has been a revision or change in the materials. use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product. for sales. advertising or any other purposes shall automatically terminate this NOA. Failure to comply tyith any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County. Florida, and followed by the expiration date may be displayed in advertising literature. If am portion of the NOA is displayed. then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 1';-1020.01 and consists of pages I through 67. The submitted documentation was reviewed by Jorge L. Acebo. s i -` - NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Datc: 11/01/18 Page I of 67 ROOFING SYSTEM APPROVAL Category Roofing Sub-Cateporv: Modified Bitumen Material: APP/SBS Deck Tvpe: Wood Maximum_ Design Pressure: -105 psf. .... TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPL•InANT: • TABLE 1 """ • Test P�vri'trct "" Product Dimensions Specification DetttiMibn GAFGLASj Pk 4 39.37•7 ASTM D2178 .. . Smooth surfaced 14C (1 meter) Wide p ply slie eta• reinforced with filcrgt ; mat... Tri-Ply"' Ply 4 Ply Sheet 3 9.37" ASTM D2178 • Smooth surfaced asphaltic ply jh'et, • (I meter) Wide reinforced with figorgiass mat..... GAFGLASS' 39.377' ASTM D2178 Smooth surfaced asphaltic ply skoot,' FlePiyr" 6 (1 meter) Wide reinforced with fiberglass mat. GAFGLASff 975 Base Sheet 39.37• ASTM D4601 Smooth asphaltic base or base/ply sheet (I meter) Wide reinforced with fiberglass mat. Tri-Ph" 975 Base Sheet 39.37" ASTM D=4601 Smooth asphaltic base or base/ph- sheet (1 meter) Wide reinforced with fiberglass mat. GAFGLAS ` 40 Ultima"' Base 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet Sheet (1 meter) Wide reinforced with fibcrglass mat. GAFGLAS'- Strataventg 39.37" ASTM D4897 Smooth surfaced asphaltic perforated Perforated Venting Base Sheet (1 meter) Wide renting base sheet reinforced with fiberglass mat. GAFGLAS9 Stratavent' 39.377- ASTM D4897 Smooth surfaced asphaltic nailable venting Nailable Ventuig Base Sheet (I meter) Wide base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. Ruberoid' HW 25 Smooth 39.37" ASTM D6163 Smooth surfaced torch applied SBS base (I meter) Wide or ply sheet reinforced with a fiberglass Ruberoid' HW Smooth 39.37-- ASTM D6164 mat. Smooth surfaced torch applied SBS base (1 meter) Wide or ply sheet reinforced with a polvester Ruberoid' Mk Granule 39.3T' ASTM D616=4 mat. Granule surfaced torch applied SBS cap (I meter) Wide sheet reinforced with a polyester mat. Rubcroid' HW Granule FR 39.3T• ASTM D616=4 Fire retardant granule surfaced heat - meter) Wide welded SBS cap sheet reinforced tvi th a polyester mat. Ruberoid" HW Plus Granule 39.377- ASTM D616=4 Granule surfaced torch applied SBS cap (I meter) Wide sheet reinforced with a poh ester mat. Ruberoid" HW Plus Granule 39.37"- ASTM D6164 Fire retardant granule surfaced torch rR (I meter) Wide applied SBS cap sheet reinforced with a polyester mat. MIAM4DADEC:UNTY24 NOA No.: 18-0919.12 Expiration Date: 11/06/23 Appro-al Date: 11/01/18 Page 2 of67 Test Product Product Dimensions Specification Description Ruberow' Energ Cap"' HW 1 meter ASTM D6164 Fire retardant granule surfaced licat- Plus Granule FR (39.37-) Wide welded SBS cap sheet reinforced Frith a polyester mat. Cap sheet is factor_- coated V ith TOPCOAT' Ener&,-Cotp` .... Elastomeric Coating. '..' ...... . Ruberoid" Torch Smooth 39.37'7 ASTM D6222 Smooth surfaced torch eppked APP bale" (1 meter) Wide or ply sheet reinforced Rltlr apolvester . • mat. .... ...... Tri-Plx-' APP Smooth 3937" ASTM D6222 Smooth surfaced torch a*Md APP•cap. • •... Membrane (1 meter) Wide base or ply sheet reinforced *vyith a .' • • 0 • •' polyester mat. " ' . .... • • Ruberoidt Torch Granule 39.37- ASTM D6222 ...... • Granule surfaced torcl:appliCd APP cap. •% (I meter) ��� ide sheet rei iforced with a poNester mat. • • 0 Tri-Plx-' APP Granule Cap 39.37-' ASTM D6222 • 0 Granule surfaced torch'applield APP cpp. : • •..a Sheet (1 meter) Wide sheet reinforced xrith a polyester mat....' Ruberoid' Torch Plus Granule 39.3T7 ASTM D6222 Fire retardant granule surfaced torch FR (I meter) Wide applied APP cap sheet reinforced with a polyester mat. Ruberoid' Energx-Cap-' 39.37- ASTM D6222 Fire retardant granule surfaced torch Torch Plus Granule FR (1 meter) Wide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factor_- coated With TOPCOAT' EnerPA-Cote7" Elastomeric Coating. Ruberoid`' EnergyCap- 3 9.3 7 ASTM D6222 Fire retardant granule surfaced torch Torch Granule FR (I meter) bide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factor_ - coated \rith TOPCOAT"' Ener�_-Cotc- Elastomeric Coating. Ruberoid" 20 Smooth 39.37" ASTM D6163 SBS polymer -modified asphalt base or ply (I meter) Wide sheet reinforced with a fiberglass mat. Rubcroid" 30 Granule 39.377- ASTM D6163 Granule surfaced mop applied SBS cap (I meter) Wide sheet reinforced with a fiberglass mat. Ruberoid' 30 Granule FR 39.37" ASTM 136163 Fire retardant granule surfaced mop (I meter) Wide applied SBS cap sheet reinforced with fiberglass mat. Ruberoid'". 30 Phis Granule FR 39.37" ASTM 136163 Fire retardant granule surfaced mop (I meter) Wide applied SBS cap sheet reinforced with fiberglass mat. Ruberoid_5 Mop Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Tri-Ply SBS Granule Cap 39.37-' ASTM D6164 Granule surfaced mop applied SBS cap Sheet (1 meter) Wide sheet reinforced with a polyester mat. Intec Flex PRF 39.377' ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced Nrith a poleester mat. Ruberoid' Mop Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base (1 meter) Wide sheet reinforced with a polyester mat. Tdmr;lklMIAM I-DADE COUNTY • � NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approxal Date: 11/01/18 Page 3 of 67 Test Product Product Dimensions Specification Description Ruberoid` Mop Smooth 1,5 39.3T- AST1v1 D6164 Smooth surfaced mop applied SBS base (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid` Mop Plus Smooth 39.37_' ASTM D6164 Smooth surfaced mop applied SBS base or (1 meter) Wide ply sheet reinforced with a pohvestq"gt. Ruberoid'' Mop Plus Granule 39.37" ASTM D6164 Granule surfaced mop apjAicd SBS.oap.' (1 meter) `Vide sheet reinforced i� ith M poh ester mat. . Ruberoid" Mop Plus Granule 39.377' ASTM D6164 Fire retardant granullVilrated mCp FR (1 meter) Wide applied SBS cap sheet r 'l forced w itl! a polyester mat. :...:. Ruberoid=E-nergyCap" Mop 39.37" ASTM D6164 Fire retardant granuIp.VVf,1ccd mop Plus Granule FR (1 meter) Vide applied SBS cap shec4 %�Torcedovvitk polyester mat. Cap rkla".it factor• coated `citli TOPCOAT` Energy Cote` ., Elastomeric Coating. ,•• : '..' Ruberoid" Mop Granule FR 39.37" ASTM D6164 Fire retardant granuICturftced 11jop•.• (l meter) Wide applied SBS cap sheet reinforced th9tl2 a polyester mat. Ruberoid" EnergyCap" 30 39.37" ASTM D6163 Fire retardant granule surfaced mop Granule FR (1 meter) Wide applied SBS cap sheet reinforced with a fiberglass mat. Cap sheet is factory coated with TOPCOAT' EnergyCote' Elastomeric Coating. GAFGLAS" Mineral -Surfaced 39.37° ASTM D3909 Granule surfaced asphaltic cap sheet Cap Sheet (I meter) Wide reinforced x ith fiberglass mat- Tri-PIN-1 BUR Granule Cap 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Sheet (1 meter) «vide reinforced with a fiberglass mat. GAFGLAS'`_ EnergyCap" 39.3T7 ASTM D3909 Granule surfaced asphaltic cap sheet Mineral -Surfaced Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Cap sheet is factors- coated with TOPCOAT' EnergyCote" Elastomeric Coating. TOPCOAT' ' Membrane L ; or 55 gallons ASTM D6083 Water based elastomeric coating. United Coatings" Roof Mate L 5 or ;; ASTM D6083 Water -based elastomeric coating TCM Coating Gallons TOPCOAT` Surface Seal SB or 55 gallons ASTM D6083 United Coatings" Surface Seal ; or ;; Gallons ASTM D6083 SB Roof Coating TOPCOATS NIB Plus United Coatings"' Roof Mate NIB Plus Coating i or» gallons or;5 Gallons Proprietan Proprietan Solvent based thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. Solvent -based thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase roof' r0ectivity. Water based_ loxv VOC primer used to block asphalt bleed -through. Water based. low VOC primer designed to block asphalt bleed -through. NOA No.: 18-0919.12 MfAMI-DADE COUNTY y, Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 4 of 67 Test Product Product Dimensions Specification Description FireOut" Fire Barrier Coating 5 or 55 gallons Proprictan- Low VOC, water -based fire barrier coating. Flex Seal' I.5 gallons TAS 139 Solvent -based elastomeric sealant. e..e or 1 qt. tube .e•••. VersaShield' Fire -Resistant 12" x 100' rolls ASTM D226 Non -asphaltic fibcrglasslansA 06 *000 Roof Deck Protection underla��ment and /or fire�rr+ier. . sees.. • • e s.ee.. VersaShield'e Solo' Fire- 42" roll Nvide. ASTM D146. Non -asphaltic- fire resisWLfiberglgs � ..,... :sees: Resistant Slip Sheet 100 ft. D828, D4869. underlayrnent 'sees • • see:* • D6757 sees.. sees. Matrix" 102 SBS Membrane 3. 5 or 55 gallons ASTM D3019 Fiber reinforced rubbetieac7ild-appLiQe4.: Adhesive adhesive for modified bitfiV* roof . • SCStemS. ' ' ; • • • ...:. .. • sees sees.. sees APPROVED INSULATIONS: Table 2 Product Name Product Description Manufacturer (With Current NOA) Energ\-Guard' Polviso, Insulation Pokisocv anurate foam insulation GAF EnergyGuard" Tapered Polviso Insulation Polvisocyanurate foam insulation GAF EnergyGuard' RA Polviso Insulation Poh-isocvanurate foam insulation GAF EnergyGuard" RE Polviso Insulation Polylsocyauurate foam insulation GAF EnergyGuard— RH Tapered Polviso Pol. isocvanurate foam insulation GAF Insulation Energ-,-Guard' RN Polviso Insulation Polvisoc-vanurate foam insulation GAF EnergyGuard"' Perlite Recover Board Perlite recover board GAF EnergyGuard' Perlite Roof Insulation Periit.c insulation board GAF EnergyGuard' R-A Composite Poh•iso Polvisoc-vanurate foam insulation GAF Insulation with high density fiberboard or permalite Structodek", High DensitA- Fiberboard Roof High density fiberboard Blue Ridge Fiberboard, Inc. Insulation SECUROCKI Gypsum -Fiber Roof Board Gypsum board United States Gypsum Corp. SECUROCKI Glass -Mat Roof Board Gypsum board United States Gypsum Corp. DensDeckE Roof Board Gypsum board Georgia-Pacific DensDeck' Prime Roof Board Gypsum board Georgia-Pacific E COUNTY NOA No.: 18-0919.12 MIAMi•DAD y� �a Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 5 of 67 APPROVED FASTENERS: TABU. 3 Fastener Product Product Manufacturer Number name Description Dimensions (With Current NOA) 1. Drill-TecT" 41.2 Fastener Phillips head. modified 412 x 8" GAF buttress thread, pinch Max. Length point. carbon steel fastener #3 Phillips for use in steel or Nvood head. so** • decks. With CR-10 .... ...... • coating. Available with a • • • � • • ....:. pinch point or drill point. • • • 2. Drill-TecT" 914 Fastener Truss head. self -drilling. # 14 N 16" ::::::GAF :...:. ' pinch point. high thread Max. Length ..... ..... fastener for use in steel, 43 Phillips ...... . . • ..... wood or concrete decks. head. .. .. .. .. ...... • 3. Drill-TecT" XHD Fastener Truss head. self -drilling- 915 x 16" :GAF.. pinch point, high thread Max. Length . '..' ....:. fastener for use in wood or 43 Phillips • • • • • • • steel decks. Carbon steel head. • • • • extra heavy dut\' fastener used in steel decks. 4. Drill-Tec'" 3" Steel Plate Round Gal alume`� steel 3" Round GAF stress plate -with reinforcing ribs and recessed for use with Drill - Tee' fasteners. 5. Drill-Tec" 3" Standard Galvalunic`r coated steel 3" Round GAF Steel Plate stress plate 1'or use with. approved Drill-TecT" fasteners. 6. Drill-TecT" ASAP 3S Drill-TecT" #12 fastener 412 x 8" GAF with Drill-TecT" 3" Max. Length Standard Steel Plate. 93 Phillips head xN ith 3" Round plate 7. Drill-TecT" AccuTrac' Flat A2-SS aluminized steel 3" square: GAF Plate plate for use with Drill- .017" thick TecT" fasteners. 8. Drill-TecT" AccuTrac= Gahvalume'4' steel plate 3" square: GAF Recessed Plate with recess for use \cith .017" thick. Drill-TecT" fasteners. 9. Drill-TecT"' 3 in. Ribbed Round Gals alunie ` plated 3" Round GAF Galialume Plate (Flat) steel stress plate with reinforcing ribs for use with Drill-Tec"' fasteners. NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 6 of 67 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date FM Approvals 3001276 FMRC 4470 01/28/99 301021.5 FMRC 4470 03/01/01 3029832 FMRC 4470 05/11/07 3036980 FMRC 4470 08/1.4/0� ..... 3034312 FMRC 4470 ; .04/09/09"" 3040738 FMRC 4470 0-1/18/11... % 3042887 FMRC 4470 ����j1/14/11 • 3046081 FMRC 4470 Q2/I3/13 . 3043633 FMRC 4470 '...0/20/11"' 1B9A8_AM FMRC 4470 ....99/04/97. 3B9Q LAM FMRC 4470 •09•0/08/09 • •' • 3D4Q2.AM FMRC 4470 ;••;81J30/97 • OD1A8.AM FMRC 4470 • 04/01/9a01 •. 797-03221-267 FMRC 4470 .09/24/01 " 797-10228-267 FMRC 4470 " 01/15/Ii: 797-04694-267 FMRC 4470 ON17/09 • 797-03925-267 FMRC 4470 07/14/08 RR203450 FMRC 4470 12/04/15 FM Letter FMRC 4470 04/1.1/13 FM Letter FMRC 4470 09/15/15 UL LLC R1306 UL 790 08/21/19 IRT-ARGON Inc. 02-005 TAS 114-J 07/ 19/04 02-014 TAS 114-J 04/08/02 Trinity I ERD C8500SC.11.07 ASTM D6862 11/30/07 G30250.02.10-2 ASTM D6222 11/11/1.0 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 03/31/10 G32520.06.11 ASTM D 1876 06/28/11 G33470.01.11 ASTM D6164 01/13/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 .ASTM D4601 6/4/2015 G34140.04.11-5-R3 ASTM D4897 6/4/2015 G36780.07.11-R1 TAS 114-J 07/19/11 G40620.07.12-2 ASTM D6222 07/17/ 12 G40630.01.14-1 ASTM D6163 01 /06/ 14 G40630.01.14-2A ASTM D5147 01/07/14 G40630.01.14-2A-1-RI ASTM D6164 04/10/14 G40630.01.14-2B-R1 ASTM D6164 01/16/15 G40630.01.14-2C ASTM D6164 01 /07/ 14 G40630.03.14 ASTM D5147 03/06/14 G43190.03.14-1 ASTM D5147 03/06/ 14 G43190.03.14-2 ASTM D5147 03/06/14 G43190.05.14-R 1 ASTM D5147 0S/20/ 14 G43610.01.14 ASTM D5147 01/22/14 NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 7 of 67 EVIDENCE SUBMITTED: (CONTINUED) Test Agency Test Identifier Description Date Trinity ERD G43190.11.I3-1 AST;vl D6222 11/1�/13 G46160.02.15 ASTM D6163 02/12/15 G46160.02.15-2D-1 ASTM D6163 02/09/16 G46160.03.15 ASTM D6163 03/11/15 G46160.09.14-2A ASTM D-5147 0 0 09/09A1 : � * • G46160.09.14-3A ASTM D6164 •.0 • ;09/09/.14 0 G46160.09.14-3B D6164 w w w w w.09/09Z" 0 0 0 G46160.09.14-3C .ASTM ASTM D-5147 ...:w.09/09/14 w G46160.12.14-3E .ASTM 136164 • • • •.l2/29114 G6850.08.08 ASTM D6163 , 00 ,.:0 0000 08/0 008 G6850.08.08-R1 ASTM D6164 ":00:04/144rl . ; G6850.10.08 ASTM D6222 " " 10/06/OV G6850.11.08 ASTM D6222 : � �: �:02/17/09 0 SC6870.08.14-R1 ASTM D3909 009/04'14 � : - . w PRI Constniction Materials GAF-122-02-01 TAS 139 005/0706". Technologies. LLC GAF-245-02-01 ASTM D6093 06/10/N00 GAF-276-02-01Rex ASTM E2178 01/04/11 ASTM D6083 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2179 08/231 GAF-369-02-01 ASTM C 1289 10/22/12 GAF-434-02-0 3 TAS 114-J 09/06/ 13 GAF-434-02-04 TAS 114-J 09/06/13 GAF-464-02-01 ASTM C1289 02/06/14 GAF-498-02-01 ASTM D6083 09/16/16 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-559-02-01 TAS 117(B) 09/30/14 GA F--5 _59-02-04 A STM D 1876 10/01/ 14 GAF-559-02-0-5 ASTM D1876 10/1-5/14 GAF-5-59-02-06 TAS 114(H) 10/02/14 GAF-559-02-07 ASTM D903 10/02/14 GAF-559-02-08 ASTM D903 10/02/14 GAF-> 9-02-09 ASTM D903 10/02/14 GAF-559-02-11 TAS 114-J 10/14/14 GAF-559-02-12 TAS 114-J 10/14/14 GAF--559-02-13 TAS 114-J 10/15/14 GAF-5-59-02-14 TAS 114-J 10/15/14 GAF-5-59-02-15 TAS 114-J 10/15/14 GAF-559-02-16 TAS 114-J 10/15/14 GAF-559-02-18 TAS 114-J 10/1-5/14 GAF-559-02-19 TAS 114-J 04/10/15 Dy natech Engineering Corporation 44482.02.95-1 TAS 114-C 09/01/9� NOA No.: 18-0919.12 MIAM!•DADE COUNTY Expiration.Dare: 1 1/0(>/23 saw Approval Date: 11/01/18 Page 8 of 67 Membrane Type: SBS Deck Type II: Wood, Insulated Deck Description: Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(12): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently partially adhered to insulation. All General and System Limitations shall apply. • • Fire Barrier: • • FireOut' Fire Barrier Coating, VersaShield' Fire -Resistant Slip'Sbeet'or . (optional) VersaShield' Solo' Fire -Resistant Slip Sheet. ...... ;""' Anchor sheet: GAFGLAS' 475 Base Sheet, Tri-Ply' #75 Base Sheet, Ruberoid!' -;Q,Smoot4 or GAFGLASI Stratavent' Nailable Venting Base Sheet is secured gg Scribe j • •' • • below.Miami-Dade County Approved min. 12 ga. annular ring shank nall�jap� min. 15/8 fFasDtening in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wijle dhcjtor shut . side laps and 8 in. o.c. in the fie the sheet in two staggered rows.. '..' (Maximum Design Press S:jjpsf,See General Limitation #r*"711• 0 6066 Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. !- Option #2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure —52.5 psf, See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #3: AccuTrac'l Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure —52.5 psf, See General Limitation: #7) Fastening Drill -Tee' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #4: AccuTracO Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12. in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure —67.5 psf, See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #5: AccuTracl Flat Plates or Drill-Tec'°' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure —82.5 psf, See General Limitation #7) One or more layers of any of the following insulations. Insulation for Base Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardT°' Polyiso Insulation, EnergyGuard' Tapered Polviso Insulation, EnergyGuard' Ultra Polyiso Insulation, EnergyGuard'" RH Polyiso Insulation, EnergyGuard' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-401bs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 33 of 67 Base Sheet: GAFGLAS'ff' Stratavent' Perforated Venting Base Sheet is loosely -laid over the insulation with 2 in. side laps Ply Sheet: Install one or more plies of Ruberoid' 20 Smooth adhered with any approved mopping asphalt applied within the EVT range and at a rate of 2040 lbs./sq. (See General Limitation #4). Membrane: uberoid' 30 Granule FR, Ruberoid' 30 Plus Granule FR, Ruberoid' Mop ranule, Tri-Ply`' SBS Granule Cap Sheet, Intec Flex PRF Ruberoid" Mop**o GranulTM ••.• e FR, Ruberoid' Plus Granule FR, Ruberoid' En e Mop •.•.•• • •• Plus Granule FR, Ruberoid' EnergyCap"` 30 Granule FR, GA 'g' Mfietal�• Surfaced Cap Sheet, Tri-Ply" BUR Granule Cap Sheet or GAFC44W • En^ ergy'Cap�MinTeral-Surfaced Cap Sheet adhered in a full mopping of approved • ; • • • •; asphalt applied within the EVT range and at a rate of 2040AtAsgt * :so*** ..... Surfacing: Optional on granular surfaced membranes; required for Mobih " • • • • • •; • membranes. Chosen components must be applied accordieg to : ' . manufacturer's application instructions. All coatings must belisted with.in. • .•..% a current NOA. • • • • • L • • • l . Gravel or slag applied at 4001bs./sq. and 3001bs./sq. respectively in a floodWt of approved asphalt at 60 lbs./sq. 2. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating applied at a minirPium rate of 1.0 gal./sq.(to be used as a primer) followed by TO,�COATS' Membrane or United Coatings" Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01/18 Page 34 of 67 WOOD DECK SYSTEhI LIMITATIONS. l A slip sheet is required with GAFGLAS" Ply 4 and GAFGLAS" FlexPly"' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'ia"' DensDecV' Roof Board or Type X g�-psum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple lavers. The first layer shall be attached in compliance Avith Product Control Approval guidelines. All other lavers shall be adhered in a full mopping of . • • • • approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or nneebartic;llv attached using the fastening pattern of the top laver � .. ...... I All standard panel sires are acceptable for mechanical attaclunent. \NThen applied irrapprim-ed asphalt, panel size shall be 4' x 4' mammum. 4. An overlay and/or recovery board insulation panel is required on all applications o\ er t;tcsed cel; foam insulations when the base sheet is fully mopped. If no recovery board is used M* sheep.- shall be applied using spot mopping with approved asphalt. 12" diameter circles, 21'?o.c : or strip? • • • mopped 8" ribbons in three rows. one at each side lap and one down the center of the s;c;t allowin j a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break sjnall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of ftwt system shall* beat a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maxirfk * � • design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Cliaracterisdc Force (F') value of 275 lbf.. as tested in compliance Nvith Testing Application Standard TAS 105. If the fastener value. as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined b% the Building Official. a revised fastener spacing, prepared. signed and scaled by a Florida Registered Engineer. Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation 49 will not be applicable.) 8. All attachment and sizing of perimeter nailers. metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation 47 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 18-0919.12 Expiration Date: 11/06/23 Approval Date: 11/01.11.8 Page 67 of 67 "Delivering Excellence Every Day" ------ MIAAff-DADE COUNTY ------ REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner it deli required ated space indicates that d to explain to the owner the content of this form. The owner's initials m b'm has been explained. 1. Aesthetics -workmanship: Tie workmanship provisions of Chapter 15 (High Velocity Hurricane d water intrusion Zone) are for the purpose of providing that the roofing system meets the wind resistance tc wo kman ,�P provisions . performance standards. Aesthetics (appearance) are not a consideration with p Q Aesthetic, issues such as color or architectural appearance, that are not part of a zoning Dade; shou�cl'b� addrea ad • as p f the agreement between the owner and the contractor. ...... 2. Renaili_ng wood decks: When replacing roofing, the existing wood roof die 09 fray hey: •t0. o be ; •• ••; reXalled' accordance with the current provisions of Chapter 16 (High Velocity Hurri�aane Zoned of the Fl®r�cia• • ..... Bode. (The roof deck is usually concealed prior to removing the existing roof syst• Common roofs: Common roofs are those which have no visible delineationbetweeanelghbor�;• uownhouses, condominiums, etc.). In buildings with common roofs, the roo g g ontrabtor nd/or. owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be therefore roofing nail view d from below. The owner may wish to maintain the architectural appearance; , penetrations of the underside of the decking may not be acceptable. The owner provides the option of mak ta' g this appearance. I t � 5. Ponding water: The current roof system and/or deck of the building may not drain well and may ca e water to pond (accumulate) inlow-lying areas of the roof. Pondingonding may shorten the life distress and may require the review of a professional struengineer.can be an indication of structural ctural ditions may not be evident until the original expectanLy and performance of the new roofing system. Ponding cono g stem is removed. Ponding conditions should be corrected. r j' 6.Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not over aded from a build up of water. Perimeter/edge walls or other roof extensions may w scuppers this ersdiusah discharge overflow scuppers (wall outlets) are not provided.' :It may be necessary to install overflow pp Vintr uirements of Chapter 15 and 16 herein and the Florida Building Code, Plumbing. entilation: Most roof structures should have some.ability to vent natural action shathrough the e structural assembly (the building itself). The existing amoWnt of attic vent reduced. i Date: Owner's/.Agent's Signature: Permit Number: Contractor's Signature: Property Address: i1/!� �" (any Wei L AW