Loading...
RF-20-379Miami Shores Village 10050 NE 2 Ave Miami Shores Fl. 33138 305-795-2204 Issue Date: 02/26/2020 Location Address Parcel Number 78 NW 110TH ST, Miami Shores, FL 33168 1121360030070 Contacts Permit NO.. RF-02-20-379 Permit Type: Roof Work Classification: Flat Permit Status: Approved Expiration: 08/ 18/2020 Wilner Nordelus Owner FLORIDA QUALITY ROOFING INC Contractor 78 110 GERMAN DUARTE 4317 NW 167 St, Miami Gardens, FL 33054 Business:3053067663 german@floridaqualityroofing.com Description: RE ROOF FLAT ROOF ONLY Valuation: $ 3.500.00 Inspection Requests: 1305-762-4949 Total Sq Feet: 400.00 Fees Amount Application Fee - Other $50.00 CCF $2.40 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $0.80 Roofing Fee $200.00 Scanning Fee $9.00 Technology Fee $6.25 Total: $274.70 Payments Date Paid Amt Paid Total Fees $274.70 Check # 1148 02/26/2020 $224.70 Check # 1132 02/20/2020 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction §10A zoning. Futhermore, I authorize the above named contractor to do the work stated. r Authorized Signature: II / Applicant / / Agent Date February 26, 2020 Page 2 of 2 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # jQF" OZ 2O` 37 9 DATE: INSPECTION AFFIDAVIT I C—K.(rY1A n -Duo t i " licensed as a (r6ntracto / Engineer / Architect, (Print name and circle License Type) FS 468 Building Inspector License #: CC C 13 z S` 0 X 9 On or about 03 ! 02 IZOZO , 1 did personally inspect the roof deck nailing (Date & time) work at 7 Q N W !/ D*t, -0 (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) C;o// Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me thisy a day of %NA✓LGl — Josseyn Duane NOTARY PUBLIC _ Notary Public, Sate of Florida at Large STATE OF FLORIDA Cww*GG213466 Expires SM022 'General, Building, Residential, or Roofing Contractors or any individual certtried under 468 F.S, to make such an inspection. Include photographs of each plane of the roof with permit # and address # dearly shown marked on the deck for each inspection Miami Shores Village TO l-?,o� Building Department �\ ✓ 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ENTERED FEB20200 BY: (I FBC 201-7 Master Permit No. e4"'02- ^ W' 319 Sub Permit No. ❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL PUBLIC WORKS CHANGE OF ❑ CANCELLATION SHOP CONTRACTOR DRAWINGS JOB ADDRESS: % O NW I I U A S f City: Miami Shores County: Miami Dade Zip:.331 LPd Folio/Parcel#: 1I-213(p`,DU3 0070 Is the Building Historically Designated: Yes NO' Occupancy Type: S d_wfo oad: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): kk MCWLP_ ` wke'r NDr`iMu S Phone#: Address: -7 A NW i (Ot-" SiY-ee+ City: Mdwll Aore.t State: Zip: �)paD Tenant/Lessee Name: N 1k Phone#: 3o!�' 0 (S-cjgq y Email: P01V64VIOYCOVS C GrA alb . ww CONTRACTOR: Company Name: :B on jcI r)JCjc(fU j26o�q, (PlC Phone#: •3D,�_-30(ifhA93 Address: 2q-2I WE, L(•I'H ftj!, City: /� lYI r0 Pu State: � Zip: 33dloL4 i Qualifier Name: �U(7 Var+e, Phone# State Certification or Registration #: CCC 132 SY 99 Certificate of Competency #: _ OS--3W__? of 3 DESIGNER: Architect/Engineer: (lam Phone#: Address: 9?,(0j(Ar\e FIUr14�A�UQ.IeIM nG•CUM City: State: Zip: tt ���'�` Value of Work for this Permit: $ DU 6 o Square/Linear Footage of Work: 'T00 Type of Work: El Addition El Alteration El New E Repair/Replace ❑ Demolition Description of Work: ke-AUOF F(C44- )P-00E UYF ly �r- �'• 1 L t •r...��4 t Specify color of color. thAi_Vle: ,i'�` Submittal Fee $ ''Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Technology Fee $ Structural Reviews $ Radon Fee $ Training/Education Fee $ DBPR $ Notary $. Double Fee �$•�� Bond $ (Revised02/24/2014) TOTAL FEE NOW DUE $ a�' 1 Bonding Company's Name (if applicable) N /1- Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City PIK State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatu Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this 31 dayof U►1UO 20 ZO by ii1Q Pf WWde,INS, who is personally known to,, me or who has produced The foregoing instrument was acknowledged before me this -744" day ofV 20 243 , by yrl'Q/i 01 rl bJC4�-R, , who isq ersonally knovy to as me or who has produced identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: as Sign: Sign: Print:h buboc Print: �C� ✓I bVol < &PAy osse yn a *44tE Josseyn Duarte Seal: NOTARY PUBLIC Seal: 'NOTARY PUBLIC -ESTATE OF FLORIDA .STATE OF FLORIDA m : Cam# GG213466 Comm# GG213466 • �� E 19�� Expires 5/2/2022 Expires 5/2/2022 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Summary Report Property Information Folio: 11-2136-003-0070 Property Address: 78 NW 110 ST Miami Shores, FL 33168-4319 Owner WILNER NORDELUS & HERMANCE E ANTOINE Mailing Address 78 NW 110 ST MIAMI SHORES, FL 33168-4319 PA Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3 / 1 / 0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 1,347 Sq.Ft Lot Size 9,150 Sq.Ft Year Built Multiple (See Building Info.) Assessment Information Year 2019 2018 2017 Land Value $206,472 $196,886 $196,886 Building Value $93,751 $93,751 $93,751 XF Value $1,359 $930 $945 Market Value $301,582 $291,567 $291,582 Assessed Value 1 $94,557, $92,913 $91,002 Benefits Information Benefit Type 2019 2018 2017 Save Our Homes Cap Assessment Reduction $207,025 $198,654 $200,580 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES EXT PB 43-40 LOT 7 BILK 219 LOT SIZE 75.000 X 122 OR 16564-4725 1094 1 Generated On : 2/20/2020 Taxable Value Information 2019 2018 2017 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $44,557 $42,913 $41,002 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $69,557 $67,913 $66,002 City Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $44,557 $42,913 $41,002 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $44,557 $42,913 $41,002 Sales Information Previous Sale Price OR Book -Page Qualification Description 10/01/1994 $77,000 16564-4725 Sales which are qualified 12/01/1971 $26,500 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version Miami shores Village Budding Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: a) 1212 02© 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: A&h1cont N 0I&S Property Address: "1 N W I f 0 " S- -, Yyl l cvn l ,-vtor� s i 3311� Roofing Permit Number: Dear Building Official: WWto n Ce No S certify that I am not required to retrofit the roof to wall connections of my building because: ,c?�he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00, Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions 4of99 edition of the So lorida Building Code (1994 S BC) 40Y C'I� Signature State of Florida County of Dade Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of Josselyn Duarte � tARY,� NOTARY PUBLIC -STATE OF FLORIDA W ? Comm# GG213466 Notary Public, Sate of Florida at Large �s�NCE,e1� Expires 5/2/2022 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 006112 Local Business Tax4eceipt Miami -Dade County, State of Florida -THIS IS NOT A BILL - DO NOT PAY ti 6053383 •BUSINESS NAMOCATION RECEIPT NO. EXPIRES r FLORIDA QUALITY ROOFING INC RENEWAL DOING BUSINESS IN DADE COUNTY 6314678 Must 32020 `'" ust be displayed at place of business + Pursuant to County Code Chapter BA - Art. 9 & 10 O OWNER SEC. TYjEOF BUSINESSPAY: FLORIDA QUALITY ROOFING INC 1 196 SPECIALTY BUILDING CONTRACTOR : BYTAXC COLLERECEICTOR 1 GERMAN DUARTV QUALIFIER ; CCC1325689 eytnxcotLECToa $75.00 09/27/2019 Worker(s) a . ECHECK�l-9-235155 f . � This Local Business Tax Receipt only confirms payment otl o Local BuslnessTax. The Receipt is not a license, permit, or a certification of the holder's qualifications, to do business. Holder most comply with any governmental or aongovemmental regulatory laws and requirements which apply to the business. The RECEIPTNO. above must bo'disptaysdon all commerclat,vet icles - Miami -Dade Code Secea-276. Far more information, visit www.miamidatlaxey1taxcollector r i` �1( , 4 x r Client#: 1782965 R F-02-20-379 FLORIQUA ACORD. CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) 102/20/2020 THAS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer any rights to the certificate holder in lieu of such endorsement(s). PRODUCER USI Insurance Services LLC 2502 N Rocky Point Dr. Suite 400 NAppMEACT Sam Gordon P�HONN E 855-874-1270 FAX A/C No E-MAILAREss. sam.gordon@usi.com Tampa, FL 33607 INSURERS AFFORDING COVERAGE NAIC # 855 874-1270 INSURER A •Kinsale Insurance Company 38920 INSURED Florida Quality Roofing Inc. 2421 NE 4th Avenue INSURER B • Amr-uard Insurance Company 42390 INSURER C: Pompano Beach, FL 33064 INSURER D : INSURER E INSURER F : COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSRR TYPE OF INSURANCE DDL UBR WYJLPOLICY NUMBER POLICY M/LIC YYYY POLICY YYY LIMITS A X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE u OCCUR 01001048330 1 /08/2020 01 /08/2021 EACH OCCURRENCE $1 000 000 AM T RENTED $100000 MEDEXP (Any oneperson) $Excluded PERSONAL & ADV INJURY $1 OOO 000 GEN'L AGGREGATE LIMIT APPLIES PER: PRO - �I JECT LOC POLICY U OTHER: GENERAL AGGREGATE s2,000,000 PRODUCTS - COMP/OP AGG s2,000,000 $ B AUTOMOBILE LIABILITY X ANY AUTO OWNED SCHEDULED AUTOS ONLY AUTOS HIRED NON -OWNED AUTOS ONLY AUTOS ONLY FLAU144442 1/23/2020 01/23/2021 COMBINED SINGLE LIMIT 1 000 000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE $ $ UMBRELLA LIAB EXCESS LIAB HCLAIMS-MADE OCCUR EACH OCCURRENCE AGGREGATE DED RETENTI N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? ❑ (Mandatory In NH) If yes, describe under DE CRIPTI N F PERATION I w N / A PER OTH- E.L. EACH ACCIDENT E.L. DISEASE - EA EMPLOYEE E.L. DISEASE -POLICY LIMIT DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more space Is required) Contractor's License Number: CCC1325689 Miami Shores Village Building Dept. 10050 NE 2nd Ave Miami Shores, FL 33138 LA SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) 1 of 1 #S27971841/M27762137 - 1}vk7 @ 1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD SXGEW CERTIFICATE OF LIABILITY INSURANCE Date 2/20/2020 Producer: Plymouth Insurance Agency This Certificate is issued as a matter of Information only and confers no 2739 U.S. Highway 19 N. Holiday, FL 34691 rights upon the Certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. 1 (727) 938-5562 Insurers Affording Coverage NAIC # Insured: South East Personnel Leasing, Inc. & Subsidiaries Insurer A: Lion Insurance Company 11075 InsurerB: 2739 U.S. Highway 19 N. Holiday, FL 34691 Insurer C: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date Policy Expiration Date Limits (MM/DD/YY) (MM/DD/YY) GENERAL LIABILITY Each Occurrence 5 Commercial General Liability Claims Made ❑ Occur Damage to rented premises (EA occurrence) 5 Mad Exp Personal Adv Injury General aggregate limit applies per: Policy ❑Project ❑ LOC General Aggregate Products - Comp/Op Agg AUTOMOBILE LIABILITY Combined Single Limit (EA Accident) S Any Auto Bodily Injury All Owned Autos (Per Person) Scheduled Autos Bodily Injury Hired Autos Non -Owned Autos (Per Accident) Property Damage (Per Accident) EXCESS/UMBRELLA LIABILITY Each Occurrence Aggregate Occur ❑ Claims Made Deductible A Workers Compensation and Employers' Liability WC 71949 01/01/2020 01/01/2021 x I We Statu- tory Limits OTH- ER E.L. Each Accident $1,000,000 Any proprietor/partner/executive officer/member E.L. Disease - Ea Employee $1,000,000 excluded? NO If Yes, describe under special provisions below. E.L. Disease -Policy Limits $1,000,000 Other Lion Insurance Company is A.M. Best Com any rated A (Excellent). AMB # 12616 Descriptions of Operations/Locations/Vehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 36-66-074 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company": Florida Quality Roofing, Inc. Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or email certificates@lioninsurancecompany.com Project Name: ISSUE 02-20-20 (SS) Bealn Date: it 29 2018 CERTIFICATE HOLDER CANCELLATION MIAMI SHORES VILLAGE BUILDING DEPARTMENT Should any of the above described policies be cancelled before the expiration date thereof, the issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any kind upon the insurer, its agents or representatives. 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 f��-- ROO S S �iRUCTURES ONE L�.� �ijs Florida Building Code 5th Editio :,�J�fl� OF,oT By ia9e , Nigh -Velocity Hurricane Zone Uniform PetmW'A�III n r Section A (General lnformatian) � �(J� gtic Master Permit Na. � F Process No. S _ 4A, <t Contractors Name_ Uc_-)X"A&A Job Address j N,S _ �'� A0 �\ fee "� /`� 10a (r, �Ci Y t F L ROOF CATEGORY �. ." w SI ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles � ' �� Agphaltic s ❑ Metal PaneUShingfes ❑ Wood Shingles/Shakes i� 0 Prescriptive BUR-RAS 15o � ROOF TYPE ewt oiv ❑ Repair ❑ Maintenance Reroofing ❑ Recovering N ROOF SYSTEM INFORMATION t la0e Roof Area (SF Steep Steep Sloped Roof AREA (SSF) O Total (SFQ 00*0 'RGk �0Uf-o n 1 y I 0 0 g ..r.rr anz or �....:. Section B (Roof Plan) ... •.,s Sketch Roof IanIllustrate all levels and sections, roof drains, scuppers, overflow scuppers ant# er f � sions of sections and levels, clearly identify dimensions of elevated pressure zones and location ptpWft%..... r...r. .... ..... r• rr .... ...... ,y I ..... �t F� i { . M 1 i Z z _..._' �' o t _.___......_..._ �-� r 6zu r FLORIDA BUILDING CODE — BUILDING, Sth EDITION (2014) 15,37 0 1 i Copyright to, or licensed by.1CC (ALC'R1(:11TS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. a It ROOF ASSEMBLIES AND ROOFTOP STRUCTURES i Florida Building Code 5th Edition (2014) 1 High -Velocity Hurricane Zone Uniform Permit Application Form. 1 1 1 Section C (Low Slope Application) To PI Fastener/Bonding Material - Fill in specific roof assembly components and identify �y Dp. n 'N' �( x�1 1 manufacturer Surfacing: �) A 1 1 (If a component is not used, identify as "NA") Fastener Spacing for Anchor/Base Sheet Attachment: 1 1 \ 1 1 System Manufacturer: �rr`` ei j Ca--e D. Field: " oc @Lap, #Rows @ �" oc 1 Perimeter:" oc @ Lap, # Rows V1 @ S1__" oc 1 1 Product Approval No.: QdA csr� 9 . 1 1 Design Wind Pressures, From RAS 128 or Calculations: Corner: oc @ Lap, # Rows s @ " oc 1 �_Q� n Number of Fasteners Per Insulation Board: 1 P1: 1�.---- P2: P3:-1�? -- ���� 1 1 Field Perimeter/vli7 CornerA 1 Max. Design Pressure, from the specific pr duct 1 approval system. (2V Illustrate Components Noted and Details as Applicable: 1 1 Woodblocking, Gutter, Edge Termination, Stripping, Flashing, 1 1 Deck: Continuous Cleat, Cant Strip, Base Flashing, Counterftashing, 1 1 Type: W00Coping, Etc. 1 t I �L�t Indicate- Mean Roof Height, Parapet Height, NelgVcf Base 1 Gauge/Thickness: Flashing, Component Material, dlatarria4 Thickness •Fastene*rs 1 t Type, Fastener Spacing or Submit MantfacturPs•Details that 1 • • 1 Slope: Comply with RAS 111 and ChapfeT Is" ' ' • 001000 000 Anchor/Base Sheet & No. of Ply(s): i�1L b�t�A • • • • • • • • • • • 1 t -ii z_...._._� . . 1 Anchor/Base Sheet Fastener/Bonding aterial: .:. • • .. •. . • �.. • . .. .... .. ... Insulation Base Layer: F���1QoC>Z \SQ ,(� �4r� �u� /J�5 C yti • .. . .0 10.0 1 Base Insulation Size and Thickness: —y �y h i • Ppapet 0l� 1 • F�•n\ buy \ b�l.tck Biels ht J 1 "1 Base Insulation Fastener/Bonding Mater I: \,k vcrr 1 Top Insulation Layer: 4e,n16 0104 D_v-kj L d} �b '�' "�—t° �� -- FT. 1 1 \ Top Insulation Size and Thickness: ` 1 wt�vd 13Z�� Mean 1 Roof 1 Tap Insulation Fastener/Bondinr�gq Mat rlal, 1\\ !� Height 1 1 �\ �o�_L`i i Base Sheet(s) & No. of Ply(s): ( Base Sheet Fastener/Bonding Material: Ply Sheet(s) & No. of Ply(s): 1 Ply Sheet Fastener/Bonding Material: 1 1 1 l 1 Top Ply: � o��—0-'1 1 1 15.38 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2414) Copyright to, or licensed by, ICC (All. RIGHTS RESERVED): accessed by Eliczcr Palacio on Jun 6, 2015 10:32;12 AM pursuant to License 1 Agreement. No further reproductions authorized. I Y Engineering & Testing Co. 7450 Griffin Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net February 4, 2020 Project: Nordelus Residence- Flat Reroof Address: 78 NW 110 Street, Miami Shores, FL 33168 Roofing Contractor: Florida Quality Roofing RAS NO: 117 Calculation NOA: 17-1003.15 CertainTeed Conventional Built -Up -Roof Systems over Wood Decks Deck System Type: A(2) Page 8 and 9 of 22 of NOA: Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. Mean Roof Height = below: 20 feet RAS 128 Wind Uplift Pressures: p1= 42.8 p2= 71.7 p3= 108 as per RAS 128 (Tabel 1-Exposure Category "C" ), FBC 2017 NOA Design Pressure: pd noa= 60 NOA-Side lap row: c slr= 1 NOA-Center lap row: c clr= NOA-Side lap spacing: a slr= 8 NOA-Center lap spacing: • a`cJ" •' nw=net width (ft) sh=sheet width (in) slw=side lap width (in) nl=net length(ft) nw=(sw-slw)/12 nl=100/nw fn= number of fasteners per spacing b=nl (net lentgth per row) a=fastener spacing (in) -sir=side lap row -clr=center lap row c= number of rows @spacing "a" -slr=side lap row -clr=center lap row d=number of fastener per square side lap row d slr=(fn/a slr)*(12/1)*(b/1)*(c slr/ 1*1) d slr= 56.25 sw= 36 .... .. slw= 4 nw= 2.667 •••••• • • • v • w • nl= 37.500 fn= 1 b= nl center lap row d clr=(fn/a clr)*(12/1)*(b/1)*(c clr/ 1*1) d clr= 168.75 Page 1 t i Area per fastener as= area per square (sf/square) fa= fastener area (sf) fa=as/(d sir+d clr) Fastener Value Calculation pd noa=maximum NOA design pressure (psf) fy=fastener value (lb) p=design pressure p1 field : p2 perimeter : p3 corner fs=required fastener spacing rs=row spacing fy= pd noa*fa fy= 26.667 rs=nw*12/(c slr+c clr) rs= 8.000 rsp=proposed row spacing for perimeter (4) rsp2=(nw*12)/(1+4) rsp2= 6.400 rsp=proposed row spacing for corner areas (5) rsp3=(nw*12)/(1+5) rsp3= 5.333 Field Zone Spacing Requirement fs= (fy*144)/(p1*rs) fs= 11.215 Perimeter Zone Spacing Requirement fsp=(fy*144)/(p2*rsp2) fsp= 8.368 Corner Zone Spacing Requirement fsc=(fy*144)/(p3*rsp3) fsc= 6.667 as= 100 fa= 0.444 . . .... ...... ...... . .. ...... 4 rows in the field spJeW5t 6.44Q��.; .... . .. ..... ...... .... ..... "" 5 rows in the field saScedat 5.333":' . . .. . ...... 8 Inches; 8" o/c lap and 3 rows @*`o�c required for a total of four (4) rows; 8 Inches; 8" o/c lap and 4 rows @ 8" o/c required for a total of five (5) rows; 6 Inches; 6" o/c lap and 5 rows @ 6" o/c required for a total of six (6) rows; Prepared by: CeBB Engineering & Testing Co. (CA#9807) 02/04/20 Eduard C. Badiu, YhD, P.E. #59997 for the firm Page 2 KIjaMK MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy CertainTeed Corporation 20 Moores Road Malvern, PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that thi9p* ct or material fails to meet the requirements of the applicable building code. .. This product is approved as described herein, and has been designed to comply with the Fl ,,�� uildin ode P PP � P Y Q�.� g including the High Velocity Hurricane Zone of the Florida Building Code. 0000 .. .... . ... ..... DESCRIPTION: CertainTeed Conventional Built -Up -Roof Systems over Wood Deck.* • . • 000000 • •: • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logq-ci:y:state and -following •, statement: "Miami -Dade County Product Control Approved", unless otherwise noted herei$. """ RENEWAL of this NOA shall be considered after a renewal application has been filed aria tfierc has 12ean no change in the applicable building code negatively affecting the performance of this product. "" TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 16-0322.25 and consists of pages 1 through 22. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-1003.15 Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 1 of 22 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Built -Up Roofing Material: Fiberglass Deck Tvve. Wood Maximum Design Pressure: -60 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Black DiamondTM Base 36" x 687'; Roll ASTM D 1970 Self -adhering fiberglass reinforced modified Sheet weight: 78 lbs. bitumen base sheet (2 squares) Flintlastic Ultra Glass SA 39 3/s" x 33' 11" ASTM D 1970 Self -adhering, fiberglass reinforced, SBS modified bitumen base/ply sheet. Flintglas Ply 4 36" x 1647'; ASTM D 2178 Fiberglass, asphalt impregnated pjysj eet. Roll weight: 40/55 lbs. Type N • . . .... ...... (5 squares) UL Type G1 • • ' • • Flintglas Premium Ply 6 39 3/s" x 1647'; Roll ASTM D 2178 ...... . .. ...... Fiberglass, asphalt i"ja4Wated plysheet. . weight: 40 lbs. Type VI : 0 0 • • • (5 squares) UL Type G1 • • • • • • • ' • • •. Flintglas® MS Cap 36" X 32' 10"; ASTM D 3909 ...... .... ..... Asphalt impregnatedift"Coated i"ganic gam... CoolStar Roll Weight: 78 lbs. UL Type G3 fiber surfaced with x i"W granulegused as the* • (1 square) • • • top ply in conventional built-up:89f r4embrail • • Covered with reflective NolStat CUting. :....: Flintglas® MS Cap Sheet 36" X 32' 10"; ASTM D 3909 Asphalt impregnated and coated kvorganic glass Roll Weight: 78 lbs. UL Type G3 fiber surfaced with mineral granules used as the (1 square) top ply in conventional built-up roof membranes. Yosemite® Venting Base 39 3/8" x 32' 10" ASTM D 3909 Mineral surfaced fiberglass reinforced buffer Sheet ASTM D 4897 sheet. UL Type G3 Flintlastic Poly SMS Base 39 3/8" x 64'3" ASTM D 4601 SBS modified, polyester reinforced base/ply Sheet Grade S sheet. Type II GlasbaseTM Base Sheet 36" x 98'9"; ASTM D 4601 Asphalt coated, fiberglass base sheet. Roll weight: 69 lbs. (3 squares) All Weather/Empire Base 36" x 65' 10"; ASTM D 4601 SBS modified, fiberglass reinforced base/ply Sheet Roll weight: 86 lbs. Type II sheet. (2 squares) NOA No.: 17-1003.15 MIAMIOADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 2 of 22 Flexiglas Base Sheet Flintlastic Base 20 Flintlastic Ultra Poly SMS Base Sheet 36" x 98'9"; Roll weight: 90 lbs (3 squares) 36" x 98'9"; Roll weight: 90 lbs (3 squares) 39 3/8" x 32' 10" APPROVED INSULATIONS: Product Name F1intBoard ISO F1intBoardH ISO ACFoam-II H-Shield DensDeck, DensDeck Prime ENRGY 3, ENRGY 3 25 PSI Ultra -Max, Multi -Max FA-3 ASTM D 4601 SBS modified, fiberglass reinforced base/ply Type II sheet. ASTM D 6163 SBS modified, fiberglass reinforced base/ply Grade S sheet. Type I ASTM D 6164 SBS modified, polyester reinforced base/ply Grade S sheet. Type I TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Water resistant gypsum board Polyisocyanurate foam insulation Polyisocyanurate foam insulation Structodek High Density Fiberboard Roof High Density Wood Fiber insulation Insulation board. EnergyGuardTM Perlite Roof Insulation Perlite insulation board Fesco Board Expanded perlite and fiber insulation Manufacturer (With Current NOA) CertainTeed'•rr,"orp. ••..�. .. C.Q4ainT*d'Cp?p. • At as oofin4 rporatiox•... • *M?iter Paflels' LLC • • ; • • . ...... .... .... . Geosgie.l'aci5 G,)W'Zm Lb�.... :1;9e Manville Corp. •. . . .. . ...... �P,MaX Opernting, LLC. • Blue Ridge Fiberboard, Inc. GAF Johns Manville Corp. NOA No.: 17-1003.15 Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 3 of 22 APPROVED FASTENERS: Fastener Product Number Name 1. Dekfast DF-#14 PH3 & Dekfast DF415 PH3 2. Dekfast PLT-H-2-7/8 3. Dekfast PLT-P-R-3 4. #12 Standard Roofgrip & #14 Roofgrip 5. AccuTrac Hextra 6. 7. 8. 9. 10. 11. 3 in. Ribbed Galvalume Plate AccuTrac Plate TABLE 3 Product Description Insulation fastener Galvalume AZ50 steel plate Polypropylene plate Insulation fastener for wood and steel. Insulation fastener for wood and steel Galvalume stress plate. Galvalume stress plate. 3 in. Round Metal Plate Galvalume AZ50 steel plate Trufast #12 DP & Trufast Insulation fastener for wood #14 HD Fastener and steel decks Trufast 3" Metal Insulation Galvalume AZ50 steel plate Plate F1intFast #12 & #14 Insulation fastener for wood and steel decks Manufacturer Dimensions (With Current NOA) SFS Group USA 2'/8" x 3 1/4" SFS Group USA 3" x 3 1/4" SFS Group USA OMG, Inc. OMG, Inc. 3" round OMG,•kic. . . .... ...... 3" square 0=, rw. '. ...... • •• ...... 3" round .... Old, Inc. ; • • • • ; Njenloh, W k & C=q., * * • 3" round 0 O WNenlohi PAnck & Co.� ; Certai&AWLCorp' • •.• NOA No.: 17-1003.15 Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 4 of 22 EVIDENCE SUBMITTED: Test AEency/Identifier Name Report Date TrinitylERD TAS 117 (B) 3503.10.06 10/10/06 TAS 117 (B) 06490.04.07-R1 06/27/07 TAS 117 (B)/ ASTM D6862 C8500SC.11.07 11/30/07 FM 4470 / TAS 114 C8370.08.08-R1 10/05/09 ASTM Physical Properties C10080.09.08-R4 03/25/10 TAS 117 (B) C35500.02.11 02/09/11 FM 4470 / TAS 114 3513.08.02-R1 03/17/11 FM 4470 / TAS 114 03515.07.03-1-R1 06/27/12 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D1970 C40050.09.12-2 09/28/12 ASTM D3909 C44200.03.13 03/22/13 ASTM D2178 C47250.03.14 03/26/14 ASTM D1876 C35460.05.11-R1 ....05/20/15 ASTM D3909 CTR-SC11145.0%16-2A'.... 09/19/16 ... ASTM D3909 CTR-SC11145-09.46-2B:•. •99/19/16 •6 ASTM D4601 CTR-SC 11145 � 16-3A• ..09/19/1160• • • ASTM D4897 CTR-SCl l i4S.bVl6-4 09/19/:&..: . . . . Factory Mutual Research Corp. FMRC 4470 .... J.I.OY&AJ" . .. ..... ....03/23/Da FMRC 4454 J.I. OD30r3.?V4 .... N/04/67• • • . FMRC 4470 J.I. 1 D-IV4.= 11 /09/98 • . FMRC 4470 J.I.2DOAO.A!A 000 V . ' 12/23/W "' . .. . . Underwriters Laboratories, Inc. UL 790 R11656 '....bl/11/13 PRI Construction Materials ASTM D6163 CTC-066-02-01 08/09/11 Technologies LLC ASTM D2178 CTC-123-02-01 03/13/12 ASTM D4601 CTC-124-02-01 03/13/12 ASTM D4601 CTC-127-02-01 03/13/12 ASTM D6164 CTC-190-02-01 12/02/13 ASTM D1970 CTC-199-02-01 01/22/14 NOA No.: 17-1003.15 MIAMIOADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 5 of 22 APPROVED ASSEMBLIES: Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type A(1): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor sheet: All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Yosemite Venting Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9" o.c. in the lap and two rows staggered in the center of the sheet 12" o.c One or more layers of any of the following insulations. Insulation Laver F1intBoardR ISO, ENRGY 3, Ultra -Max, H-Shield Minimum 1" thick Fesco Board or EnergyGuardTM Perlite Roof Insulation Minimum %11 thick Structodek High Density Fiberboard Roof Insulation Minimum %1' thick DensDeck, Dens -Deck Prime Minimum'/a" thick . . .... ...... Insulation Fastelfel'%' Tastenet '... Table 3 * * * * * * lbensi /W...: .... . ..... ..... N/A •.*N/A ..... .. .. .... ...... . . .. . ...... N/A *••*N/A • • N/A N/A N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: Install one ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, (Optional) Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at an application rate of 20-35 lbs./sq. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved asphalt at an application rate of 20-35 lbs./sq. NOA No.: 17-1003.15 QMIAMMI-DADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 6 of 22 Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of (Optional) approved asphalt at an application rate of 20-35 lbs./sq. Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design Pressure: -45 psf (See General Limitation #9) *too . . •00: •....• go ...... .... . .. ..... 00000 .. .. .... ...... ...... . . . . •• . •6000: • •• NOA No.: 17-1003.15 MIAMI•DADE COUNTYM Expiration Date: 06/19/23 � a Approval Date: 04/26/18 Page 7 of 22 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached using approved nails spaced 6" o.c. at wood joists spaced maximum 24" o. c System Type A(2): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor sheet: All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Yosemite Venting Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8" o.c. in the lap and three rows staggered in the center of the sheet 8" o.c. One or more layers of any of the following insulations. Insulation Laver Insulation Fasteners Agener Deg jij;Lft2 Table 3 ENRGY 3, Multi -Max FA-3, ACFoam-II, F1intBoard ISO, F1intBoardH ISO, H-Shield Minimum 1.5" thick N/A 0• N/A; 0000 Fesco Board or EnergyGuardTM Perlite Roof Insulation Minimum %11 thick N/A Structodek High Density Fiberboard Roof Insulation Minimum %" thick N/A DensDeck, DensDeck Prime Minimum 1/4" thick N/A •••••• •••• •• •• •••• ;••,•, N/A • N/A'••••' N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: Install one ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, (Optional) Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at an application rate of 20-40 lbs./sq. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved asphalt at an application rate of 20-40 lbs./sq. NOA No.: 17-1003.15 MIAMI-DADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 8 of 22 Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of (Optional) approved asphalt at an application rate of 20-35 lbs./sq. Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design Pressure: -52.5 psf (See General Limitation #7) ...... . .. ...... .... . .• ....• .... .. .. ...... . . . . .. . ...... . . ...... .... NOA No.: 17-1003.15 MIAMI•DAD, COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 9 of 22 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached using approved nails spaced 6" o.c. at wood joists spaced maximum 24" o. c System Type A(3): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor sheet: All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Yosemite Venting Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8" o.c. in the lap and three rows staggered in the center of the sheet 8" o.c. One or more layers of any of the following insulations. • • • • . . .... ...... Insulation Laver Insulation Fasteners' :' • >i astener '. Table 3) ... JvLvensity7iif ENRGY 3, Multi -Max FA-3, ACFoam-II, F1intBoard ISO, F1intBoardH ISO, H-Shield" ' Minimum 1.5" thick N/A N/A ...... .... ..... 00 Note: All insulation shall be adhered to the anchor sheet in full mopping of approved.hot Asphalt within the EVT range and at a rate of 20-40 lbs./100 W. Please refer to Roofing Application Standard;RAS:1-17 for • • ••: • insulation attachment. Insulation listed as base layer only shall be used only as base 1:kyer§ with A seMnd layer• • • : of approved top layer insulation installed as the final membrane substrate. Composite insulation[anels may be 000 used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved asphalt at an application rate of 20-40 lbs./sq. Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of (Optional) approved asphalt at an application rate of 20-40 lbs./sq. Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design Pressure: -52.5 psf (See General Limitation #7) NOA No.: 17-1003.15 M AAMI•DADE couNTY Expiration Date: 06/19/23 ' Approval Date: 04/26/18 Page 10 of 22 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. System Type A(4): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Yosemite Venting Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8" o.c. in the lap and three rows staggered in the center of the sheet 8" O.C. One or more layers of any of the following insulations. • • • • • • • • • • Insulation Laver ...... Insulation Fasten . .. astener ...... Table 3 .... .. D si / ' • • • ; . . ENRGY 3, Multi -Max FA-3, ACFoam-II, FlintBoard ISO, FlintBoardx ISO, H-Shield Minimum 1.5" thick ...... N/A •••• .... ...... •••��INUA ��••�• Fesco Board or EnergyGuardTM Perlite Roof Insulation • • • • •... Minimum 3/4" thick N/A .'. •• N/A ;• •; Structodek High Density Fiberboard Roof Insulation Minimum %" thick N/A N/A DensDeck, DensDeck Prime Minimum 1/4" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: Install one ply of All Weather/Empire, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic (Optional) Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at an application rate of 20-40 lbs./sq. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved asphalt at an application rate of 20-40 lbs./sq. NOA No.: 17-1003.15 Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 11 of 22 Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of (Optional) approved asphalt at an application rate of 20-40 lbs./sq. Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design Pressure: -60 psf (See General Limitation #7) . . .... ...... ...... . .. ...... .... . .. ..:Goo ...... .... ..... .. .. .... ...... . . .. . ...... . . .. NOA No.: 17-1003.15 Mia�ru•oaoe cour�mr Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 12 of 22 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type B: Base layer of insulation mechanically fastened, optional top layer adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 ACFoam-II, F1intBoard ISO Minimum 1.3" thick 1, 4, 5 1:3 ft2 ENRGY 3 H-Shield F1intBoarda ISO • • Minimum 1.4" thick 1 4 5 � 9 or 1j.. > ...... .. .1:3 ft2 • . .. Ultra -Max ...... ...... Minimum 1.5" thick 1, 4, 5, 9 or dim.. .. V. V. h2.9 ft2 ' . .. ..... ...... .... ..... Fesco Board or EnergyGuardTM Perlite Roof Insulation ..�..� •....' ...... Minimum 3/4" thick 1, 4, 5, 9 orb+; • 1:2 ft2 • . . .. . ...... Structodek High Density Fiberboard Roof Insulation Minimum %" thick 1, 4, 5, 9 or 11 •09001:2 ft2 Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). Top Insulation Laver (Optional) Insulation Fasteners Fastener Table 3 Density/ft2 Any of the insulations listed for Base Layer, above. Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Base Sheet: Install one ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, (Optional) Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at an application rate of 20-35 lbs./sq. NOA No.: 17-1003.15 MIAMI•DADE COUNTY Expiration Date: 06/19/23 - M YJAIJ Approval Date: 04/26/18 Page 13 of 22 Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved asphalt at an application rate of 20-35 lbs./sq. Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of (Optional) approved asphalt at an application rate of 20-35 lbs./sq. Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 3001b./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design . . .... ...... • • ; • Pressure: • • • • • . . -45 psf (See General Limitation .. , • • • • • • • • • • • .... . .. ..... ...... .... ..... .. .. •••• ...... . . •• • ...... .. .... NOA No.: 17-1003.15 Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 14 of 22 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type C: All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver (Optional) Insulation Fasteners Fastener Table 3 Density/ft2 ACFoam II, ENRGY 3, Ultra -Max, F1intBoard ISO, FlintBoardg ISO, H-Shield Minimum 1" thick N/A N/A Fesco Board or EnergyGuardTM Perlite Roof Insulation Minimum %" thick N/A � 4N/A see .... ...... Structodek High Density Fiberboard Roof Insulation ...... . 0 ' .. ...... Minimum V2" thick N/A • • • • • • N/A • ...... 000900 Note: All layers shall be simultaneously fastened; see top layer below for fasteners aqo* �nsity. • 00 Top Insulation Laver Insulation Fastmnem .Fastener .' (Table ; • si /fV• • % • -it .De ACFoam-II, F1intBoard ISO 0 0 Minimum 1.3" thick 1, 4, 5 • • • • f :3 ft2 F1intBoardR ISO, ENRGY 3, H-Shield Minimum 1.4" thick 1, 4, 5, 9 or 11 1:3 ft2 Ultra -Max Minimum 1.5" thick 1, 4, 5, 9 or 11 1:2.9 ft2 Fesco Board or EnergyGuardTM Perlite Roof Insulation Minimum %11 thick 1, 4,9 or 11 1:2 ft2 Structodek High Density Fiberboard Roof Insulation Minimum V2" thick 1, 4, 5, 9 or 11 1:2 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Install one ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, (Optional) Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or Glasbase Base Sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at an application rate of 20-40 lbs./sq. NOA No.: 17-1003.15 Expiration Date: 06/19/23 Approval Date; 04/26/18 Page 15 of 22 4 , . Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic.Base 20; Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved asphalt at an application rate of 20-40 lbs./sq. Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of (Optional) approved asphalt at an application rate of 20-401bs./sq. Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 601b./sq. 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design "Oleo** Pressure: -45 psf (See General Limitation #9) • • • • • • • • • • ...... . .. ...... .... . .. ..... .. .. .... ...... •. 00 ...... 000 . • • •♦ 000000 • • • 0000 • 00*0 NOA No.: 17-1003.15 MIAMI•DADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 16 of 22 Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type D: All layers of insulation and base sheet simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver (Optional) Insulation Fasteners Table 3 ACFoam-II, ENRGY 3, ENRGY 3 25 PSI, F1intBoard ISO, F1intBoardH ISO, H-Shield Minimum 1.5" thick N/A Top Insulation Layer Fesco Board or EnergyGuardTM Perlite Roof Insulation Minimum 1/4" thick Structodek High Density Fiberboard Roof Insulation Minimum %11 thick DensDeck, DensDeck Prime Minimum'/4" thick Fastener Density/ft' N/A Fastener . • Wasity/ft, .... ...... . • N/A ...... .. N/A • • •. . • Note: All insulation shall have preliminary attachment, prior to the installation of the rooting me*6iane at•a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Insulation Fasteners (Table 3)• • N/A ...... •••• • • N/A ....•. • N/A • Base Sheet: All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Yosemite Venting Base Sheet mechanically attached as detailed below. Fastening: OMG #12 Standard Roofgrip or #14 Roofgrip fasteners with OMG 3 in. Round Metal Plates, Dekfast DF-#14 P113 or Dekfast DF-#15 PH3 with Dekfast PLT-H-2-7/8 Plates, Trufast #12 DP or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plates or FlintFaat #12 & #14 Fasteners with F1intFast 3" Insulation Plates spaced 4" o.c. at a 4" side lap and two staggered rows in the center of the sheet, 24" o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or two or more plies of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full mopping of approved asphalt at an application rate of 20-351bs./sq. Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adhered in a full mopping of (Optional) approved asphalt at an application rate of 20-35 lbs./sq. NOA No.: 17-1003.15 Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 17 of 22 Surfacing: (Required if no cap sheet is used) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design Pressure: -45 psf (See General Limitation #9) . . .... ...... ...... . •• .•.... .••••• . .... . .. ........... . ...... .... ...... 00 . . •. . ••...• • • .• .006* 0*00 • NOA No.: 17-1003.15 MIAMI-DADE COUNTY Expiration Date: 06/19/23 4 Approval Date: 04/26/18 Page 18 of 22 Deck Type 1I: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type E(1): Base sheet mechanically attached. All General and System Limitations apply. Base Sheet: All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Yosemite Venting Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9" o.c. in the lap and two rows staggered in the center of the sheet 12" o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, flintiastic Base w, ...... Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Stet br twc=e; ntgre plies •, of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full ' * "i ing df a�ftoved • • asphalt at an application rate of 20-35 lbs./sq. • • • • • • .... .. . . . Cap Sheet: ..... . .. ..... One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar adkerad in a fulLwiopping.A..' (Optional) approved asphalt at an application rate of 20-35 lbs./sq. . • .. •'. • 000000 Surfacing: . (Required if no cap sheet is used) Any coating, listed below, used is a sirfacingo, m qt be li0SW 0 within a current NOA. Install one of the following: '..' .... :"": 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design Pressure: -45 psf (See General Limitation #9) NOA No.: 17-1003.15 MIAMI•DADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 19 of 22 Deck Type 1I: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached using approved nails spaced 6" o.c. at wood joists spaced maximum 24" o. c. System Type E(2): Base sheet mechanically attached. All General and System Limitations apply. Base Sheet: All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Yosemite Venting Base Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8" o.c. in the lap and three rows staggered in the center of the sheet 8" o.c Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, -Flint4astic 1 L;.* (1, ...... Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sftet or twq % rAgre plies •, of Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full Moping df approved asphalt at an application rate of 20-35 lbs./sq. • • • • • • Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar atmtfed in a'fulrfhopping•QP .. • • ........ ..... (Optional) approved asphalt at an application rate of 20-351bs./sq. • .. .. .... ...... Surfacing: (Required if no cap sheet is used) Any coating, listed below, used 3s a'surfacirip must be listed:. . within a current NOA. Install one of the following: 000 • • • • 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectfdelyIn a flpbtreQat of • • approved asphalt at 60 lb./sq. • 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design Pressure: -52.5 psf (See General Limitation #7) NOA No.: 17-1003.15 MIAMI•DADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 20 of 22 y Deck Type 1I: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. System Type E(3): Base sheet mechanically attached. All General and System Limitations apply. Base Sheet: All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Yosemite Venting Base'Sheet or Flintglas Premium Ply 6 mechanically attached as detailed below Fastening: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8" o.c. in the lap and three rows staggered in the center of the sheet 8" o.c Ply Sheet: One ply of All Weather/Empire Base Sheet, Flexiglas Base Sheet, Flintlastic BAsa 2D; ...... Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base sheet er twow Amore plies of: Flintglas Ply Sheet 4 or Flintglas Premium Ply 6 adhered in a full tftbpp rTg of apprbted aspfiaie • • at an application rate of 20-40 lbs./sq. • • • • • • Cap Sheet: One ply of Flintglas MS Cap Sheet or Flintglas MS Cap CoolStar a&&td in a full•mopping off'• • • (Optional) ... .. .. ....• ..... approved asphalt at an application rate of 20-40 lbs./sq. ... .... ...... Surfacing: (Required if no cap sheet is used) Any coating, listed below, used A a Surfacing, must be li%tei4; sees within a current NOA. Install one of the following: • • • •• 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectit8ly to a fl96dLVt of approved asphalt at 60 lb./sq. 0000 2. A two part coating consisting of a base coat of APOC #300 Non-Fibered Emulsion at rate of 3 gal./sq.; surfaced with 1 gal./sq. APOC#212 Fibered Aluminum Roof Coating. Maximum Design Pressure: -60 psf (See General Limitation #7) NOA No.: 0-1003.15 MIAMI•DADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 21 of 22 ,' I WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be apt%4 using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in tMoc rdws, oac.at., each side lap and one down the center of the sheet allowing a continuous area of ventila;on. Encir cling of the' strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allo" 1469s ventiladan. AsphtL4 - application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot:attached systems shall, be. limited to a maximum design pressure of -45 psf. ' .... . .. ..... 5. Fastener'spacing for insulation attachment is based on a Minimum Characteristic Force.(,N: value of 275 lbf., as. %.' tested in compliance with Testing Application Standard TAS 105. If the fastener value,- as field-tes*&,, ere belevo • • • 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based Nib minima rn fastener resistance value in conjunction with the maximum design value listed within a spzctfic syste14, Shoul,l tfie• fastener resistance be less than that required, as determined by the Building Official, a revised fastisxuet kPacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 17-1003.15 MIAMI•DADE COUNTY Expiration Date: 06/19/23 Approval Date: 04/26/18 Page 22 of 22 i- 1t p ) Sµoefs � r L T}0 M p<OFtIDP SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. . . .... ...... 2. Renailing wood decks: When replacing roofing, the existing n+ aroof deck mey have to••• • be renailed in accordance with the current provisions of Section R4403. (Thl'"Meck is usutfiy :....; concealed prior to removing the existing roof system). •. • .... . .. ..... ...... .... ..... 4. Exposed Ceiling: Exposed, open beam ceilings are where theoxxiw9ide of the roof decking • can be viewed from below. The owner may wish to maintain the architectural appearance; tjpre#pre, • • •• • • roofing nail penetration of the underside of the decking may not be acceptattle. Tft provi5es ate optiolgl ..: maintaining the appearance. • • 0000 • •.• 6. _Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. it may be necessary to install overflow Gs-, ' ccordance with the requirements of Sections R4402, R4403 and R4413. - - 13► nao � -�,-Zoe w Date Contra or Agnature Date 14 NW 110`S -k4+ Property Address Permit Number Revised on 7/9/2009 LD;07/01/2015; ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) ! High -Velocity Hurricane Zone Uniform Permit Application Form. 1 1 ! Section E (Tile Calculations) 1 For Moment based the systems, choose either Method 1 or 2. Compare the values for M, with th alues from Mt. If the M, values are greater than or equal to the M, values, for each area of the roof, then the the attachment me od is acceptable. ! 1 Method 1 "Moment Based Tile Calculations Per RAS 1 ! (P1: x _ ) - Mg: = M„ Product Appr vat M, 1 (P2: xX - ) - Mg: = Mrz Product Ap rova M, ! (P3: x% - ) - Mg: = M,, Product proval M, d 2 0'0 Required Moment ofi2es"ance (M,) From oTable IBelow d Tile CalProd Product A culations Per lBelow" Val M, •••J•• •• • .1 • •••1•• • • • • •• • 1 • •• ••• t M, required Moment Resist ce" Mean oof � eight Ro of Mope 15' 20' 5' 30' 40' 34.4 36.5 38.2 39.7 42.2 • 3:i •. 32.2 34.4 36.0 37.4 39.8 ;412 00 30.4 32.2 33.8 35.1 37.3 • 5:12 28A 30.1 31.6 32.8 34.9 26.4 28.0 29.4 30.5 32.4 LJ 7:12 24.4 2 5,A 27.1 28.21 30.0 'Must be used in conjunction with a list of moment b sed tile systems endorsed by the Broward County Board of Rules and t Appeals. ! For Uplift based the systems use Method 3. Comp ed the values for F' with the values for Fr. If the F' values are greater than or 1 equal to the Fr values, for each area of the roof, en the tile attachment method is acceptable. 1 1 Method "Uplift Based Tile Calculations Per RAS 127" 1 (P1: x L - x w: _ ) - x cos 0 = Fr, Product Approval F' (P2: x L = x w: _ ) - x cos = Frz Product Approval F' i (P3:_ x L = x w: _ - W: x cos 6 = Ft3 Product Approval F' 1 t 1 1 1 1 1 ! 1 1 1 1 t 1 1 1 Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope E3 Job Site Aerodynamic Multi ler Product Approval Restoring Mom? due to Gravity M9 Product Approval Attachment R istance M, Product Approval Required M ment Resistance M9 Caculated Minimum,Attachment Resistance F' Product Approval Requir d Uplift Resistance F, Calculated Aver ge Tile Weight W Product Approval TileDimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) Copyright to, or licensed by, ICC (ALL. RIGHTS RESERVED); accessed by Eliezcr Palacio on Jun B, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized.