Loading...
RF-20-345Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address PGTAWI-iR Issue Date: 02/19/2020 Parcel Number 136 NE 110TH ST, Miami Shores, FL 33161 1121360040430 Contacts Permit NO.: RF-02-20-345 Permit Type: Roof Work Classification: Flat Permit Status: Approved Expiration: 08/17/2020 VICTOR & MARILOU LAYUG Owner 136 NE 110 ST, MIAMI SHORES, FL 331617046 L CORTES CONSTRUCTION SERVICE LLC Contractor (RF) NANCY V CORTES 18786 NW 79 WAY, HIALEAH, FL 33015 Business: 3054543894 Description: RE -ROOF FLAT SECTION Valuation: $ 10,000.00 Inspection Requests: 305-762-4949 Total Sq Feet: 1,110.00 Fees Amount Application Fee - Other $50.00 CCF $6.00 DBPR Fee $4.13 DCA Fee $2.75 Education Surcharge $2.00 Roofing Fee $225.00 Scanning Fee $9.00 Technology Fee $6.88 Total: $305.76 Payments Date Paid Amt Paid Total Fees $305.76 Credit Card 02/19/2020 $255.76 Credit Card 02/13/2020 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and z aKtta-u ore, I authorize t � S>contractor to do the work stated. /n /G l.G JGG Ci Authorized Signature: ner / App e ant / Contractor / Agent Date February 19, 2020 Page 2 of 2 Miami Shores Village EN rERED ry Building Department FEB 1 020 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC X ROOFING F Bt—C 20 ^ [� Master Permit No. Q t" —o Z Sub Permit No ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP g'l CONTRACTOR DRAWINGS JOB ADDRESS: 4� / le' F Pa City: Miami Shores County: Miami Dade Zia: Folio/Parcel#: /1-.2 /36 - `13 O Is the Building Historically Designated: Yes NO L�-' Occupancy Type: Load: 1 /Construction Type: �f Flood Zone: BFE: (� FFF�FFE: OWNER: Name [45(Fee Simple Titleholder): I' O Phone#:2O�tl--52 �/ Address: City iaAv State: �G - p: Tenant/LessName: Phone#: Email: 7174 (2-- A� " CONTRACTOR: Company Name: C o 0.A(- S CO N SARLLAI 0" �Pa-y Phone#: 30 S- y$q-.S F'7 Address: / 81 R e, "Lk3 %R W A `/ City: #/ A/c AA State: 0 Zip: .3 3-0/ S Qualifier Name: Phone#: 30 S- /,l S`l - 5 8'95l State Certification or Registration #: C cc, /.3 3 O 2 q to Certificate of Competency #: 01 DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ op p Square/Linear Footage of Work: / / / D Type of Work: ❑ Addition ^❑—� Alteration 1 ❑� New LK Repair/Replace ❑ Demolition Description of Work: IZ e — 1'` O O r L A t ScLA .1 OIJ Specify color of color thru tile: Submittal Fee $ Scanning Fee $ Permit Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF DBPR $ CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) 15 - 4 to Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and ection fee will be charged. Signature Signatur ot O NER or AGEN CONTRACTOR The foregoing instrument was acknowledged before me this �_ day of /� UA2a� , 20 90 by �ci+ WCZ-OiZ XV4 J r who is personally known to me or who has produced identification and who did take an oath. The foregoing instrument was acknowledged before me this 4. day of r4rbyClAal 20 20 , by QTbS who is personally known to as me or who has produced NOTARY PUBLIC: 41:S u�% AMBER CORDOBA * * MY COMMISSION # GG 063399 N� oe EXPIRES: January 23, 2021 9fFOF F`3 Sign Q(�3 //�'1 Print: Aa6ev. (r�:d b4 Seal: identification and who did take an oath. NOTARY PUBLIC: as ro4:Y Pueio AMBER CORDOBA + * MY COMMISSION # GG 063399 ems, Sign: p°e EXPIRES: January 23, 2021 � FOF flO /� //`� Print: Am6r.r .dMA Seal: ..sssssrr:r:*ssss*sssss*r*sas*:: ssss s. �:,�:•�s�ss*...:.ssssss:sss*sssssr:.s.:.a:s....ss.::s:ss:s�rss�s:s:sss::ss APPROVED BY 11 Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-2136-004-0430 Property Address: 136 NE 110 ST Miami Shores, FL 33161-7046 Owner MARILOU A LAY UG &H VICTOR Mailing Address 136 NE 110 ST MIAMI, FL 33161-7046 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Beds / Baths / Half 4/2/0 Floors 1 Living Units 1 Actual Area 2,735 Sq.Ft Living Area 2,094 Sq.Ft Adjusted Area 2,213 Sq.Ft Lot Size 9,300 Sq.Ft Year Built Multiple (See Building Info.) Assessment Information Year 2019 2018 2017 Land Value $232,690 $232,690 $232,690 Building Value $154,025 $154,025 $154,025 XF Value $18,043 $18,065 ................. $18,088 Market Value $404,758 $404,780 $404,803 Assessed Value $154,451 $151,572 $148,455 Benefits Information Benefit Type 2019 2018 2017 Save Our Homes Cap Assessment Reduction $250,307 $253,208 $256,348 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description COLLEGE HEIGHTS PB 42-8 LOT 12 BLK 2 LOT SIZE 75.000 X 124 OR 19416-4549 12 2000 4 Generated On : 2/5/2020 Taxable Value Information 2019 2018 2017 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $104,451 $101,572 $98,455 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value 1 $129,451 $126,572 $123,455 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $104,451 $101,572 $98,455 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $104,451 $101,572 $98.455 Sales Information Previous Price ORBook-Qualification Description S e Page 12/01 /2000 $0 19416- Sales w hich are disqualified as a result of 4549 examination of the deed 09/01/1994 $107,500 Sales w hich are qualified 422 03/01/1994 $0 16306- Sales w hich are disqualified as a result of 4715 examination of the deed 06/01/1992 $118,000 15572- Sales which are qualified 0633 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiserand Miami -Dade County assumesno liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Property Address:i/�u Roofing Permit Number: Date,;,,_—1 ...... . .. ....% .. .. .... ...... . . .. . ...... Dear Building Official: • • • • • • • 1 �%� 1 N C `i /1 7c y • certify that: I have improved the roof to wall connections of the referenced property as required by the Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Residential Stru s as adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C. G d i✓ G jo C O /� l 2_� Signature State of Florida County of Dade Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of IZW,2420 a Notary Public, Sate of Florida at Large tPRY P� AMBER CORDOBA (SEAL) ' MY COMMISSION # GG 063399 N9l Pam EXPIRES: January 23, 2021 FOF F�� FINAL COMPLIANCE Revised on 5/21/2009 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Vi Ao iZ L 1P •r Property Address:_ l 3 N E l t n 5T M I g m I I 3 1 �,• •; •; • Roofing Permit Number: • sd • • • • • • Dear Building Official: 00 ' • • • • • I I Cl e R LN I certify that I am not required to retrofit the roof to wall connections of my building because: a? The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 19 _editi>7n oche t Florida B Itling Code (1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned, Sworn to and subscribed before me this L day ofc/av 202 0 AMBER CORDOBA * * MY COMMISSION # GG 063399 Notary Public, Sate of Florida at Large �— EXPIRES: January 23, 2021 gOF F When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5121/2009 Local Business Tex ReD t Miami-Dad'v County, State CIf Fiorlcia `�•?^t 'pi01 A*?4!j •r"ON01 NAB 716 298 LBT; i IWOWI: sip,t=Mpg truip? Ra EXPIRES Lt{?U 5 COUSTRUC11oN 5I` ILT LLC RENIEWA SEPTEMBER 30, � 18756 NW 79TH WAY 7rr1 $2sl t ♦ ti zaa+uy".^ u+ n' hs r ra MIAMI FL 33015 Nr ., -,r Icyl �i BLu.MEdIIILYritlt�, ' � LC+t�i Siawkm ;�;SF�i�aItc t!� ',��U.E+!.J� Htj r;�s c �;raa�_. 1AA ±� 1' 7lFs [�Ci1{ UN�iwna Tahi 1tiH'.pp11 eetl K7ld� ►t7M# r1 � t►CIf1 lttll;:r9� ilx» 1'�sr 1GIt>�'}t u Itn1 w �.,w.•sf, Ibar.3fitpGc�t+u+�iha11,'y{IWp�r f Tilldii+k'c+a.»R+!isxi�ss.11�t+jpr�xaj!y„'141�iN�s,�+++ Dim tri3yt4Ri�rtt��'ft{�':M!ItN►I�w{f��f11�i*�mrif�l�s;�1��r 1�2M1�il�t+ar1� "T1N !4:CfJt1 due e Wm 4R k Y4i sit G�#�Sewll rM�ac.w 11R,a1R{.1�, Cs. a �wr �s-�. y, !r_m a ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017),, High -Velocity Hurricane Zone Uniform Permit Application Form. l a r% Section A (General Information) Master Permit No. Process No. Contractor's Name L C og e 9 CIN W 51 Job Address % IJ E 11 0 S T ROOF CATEGORY • • �••••� •••••• i Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adbesiveiet Till •.. •;. ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shinglfj/Shakes . • • • • • •••••• ...• . ...•. ❑ Prescriptive BUR-RAS 150 000000 : •' • : 00000 • ROOF TYPE • • •• • •••••• ❑ New Roof 0 Repair L1 Maintenance ■ Reroofing II f. Recpvering ; • • • • • • ROOF SYSTEM " • •"' • INFORMATION • • • • Low Slope Roof Area (SF) ((p Steep Sloped Roof Area (SF) Total (SF) I l I p Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ■■■�i ■■■■■■■iiyll5i■■■■ilk ■■■t� ■■■■ ■..ME����������.■�.��I, ■■■■■■■■■■■■■■■■■■■■■■■■■ REM I__ 15.32 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Surfacing: Fill in specific roof assembly components and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment: (If a component is not used, identify as "NA") System Manufacturer: GAF Product Approval No.: I a - o914, 07 Design Wind Pressures, From RAS 128 or Calculations: Pmax1: " 2.S Pmax2: - . r Pmax3: 08. Max. Design Pressure, from the specific Product Approval system: - 52 PSF Deck: Type: W oop to Gauge/Thickness: 5f i e1 jujI000 �4 rr Slope: Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: 3)(S 26 c7attl .. Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): 1 y1-75 use Base Sheet Fastener/Bon7// aterial: 1 rl S R " 771) Ply Sheet(s) & No. of PI (s): Ply Sheet Fastener/Bonding Material: P Pff,,q-T Ty r Top Ply: 240mE P t Top Ply Fastener/Bonding Material: Wor A,,Pbwrr -tw Field: C" oc @ Lap, # Rows Z @ q" oc Perimeter: 6 " oc @ Lap, # Rows A @ " oc Corner: 6 " oc @ Lap, # Rpws -,4- @ 6.0 . Number of Fasteners Per InWat!Qm Boar$ • 0 00 ••• • ••1J1•• Field Perimeter .... ✓Corner : • • • •••••• Illustrate Components Notied•andoDetailse8 . ..: Applicable: •••••• •••••: ••• Woodblocking, Gutter, Edge T4rmipat0n, Stripping, Flashing, Continuous Cleat, Cant Strip, 0asd`%shing.QourVer- ... Flashing, Coping, Etc. • • • Indicate: Mean Roof Height, Plir,mt Height, Height of Base • • Flashing, Component Material, Mteral Thickn"4ss*Wastener Type, Fastener Spacing or Submit 6696 VImI CAY W 600 Dec/{ (PLgLt)no o 5/1 `k2j QT fnowwj se s FT. A% Parapet Height FT. /2. Mean Roof Height FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 15.33 MIAMI•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County Rom; • • • • • • • • Product Control Section to be used in Miami Dade County and other areas where allov7eA5yihe Authority .' Having Jurisdiction (AHJ). ...... . .. • ...... • • 0000 This NOA shall not be valid after the expiration date stated below. The Miami -Dade Coma" roduot• • • � • � • • • • Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) • • • • • • reserve the right to have this product or material tested for quality assurance purposes. if:M9,*broduQfor ""' • ... .. material fails to perform in the accepted manner, the manufacturer will incur the expenorsu ch testing ..... . ee. iR and the AHJ may immediately revoke, modify, or suspend the use of such product or rr;ateatewithigjthei •. jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade CaufltX4 000000 Product Control Section that this product or material fails to meet the requirements of dw pplicable.... :"": • building code. • • • • This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1030.01 and consists of pages 1 through 27. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 18-0919.07 MIAMI•DADECOUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 1 of 27 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: BUR Material: Fiberglass Deck Type: Wood Maximum Design Pressure: -97.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description • • • • GAFGLAS® Ply 4 39.37" (1 meter) ASTM D2178 . . .... ...... Smooth surfaced asphaltiL pl}� sheet rei�forped ." Wide with fiberglass mat. ...... '..� ....:. Tri-Ply® Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic pjX sheet reinforped Wide with fiberglass mat. 009000 GAFGLAS® 39.37" 1 meter ASTM D2178 Smooth surfaced as halti � �;� sheet re'1 Cd • • F1exPlyT"' 6 Wide with fiberglass mat. ...... .' GAFGLAS®#75 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or �asc`/Vely shej*t rejgfbrced. ••, Base Sheet Wide with fiberglass mat. Tri-Ply®#75 Base 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Sheet Wide with fiberglass mat. GAFGLAS® #80 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced UltimaT" Base Sheet Wide with fiberglass mat. GAFGLAS® 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic perforated venting base Stratavent® Wide sheet reinforced with fiberglass mat. Perforated Venting Base Sheet GAFGLAS® 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic nailable venting base Stratavent®Nailable Wide sheet reinforced with fiberglass mat. Bottom side Venting Base Sheet surfaced with granules. Ruberoid' 20 39.37" (1 meter) ASTM D6163 SBS polymer -modified asphalt base or Smooth Wide anchor sheet reinforced with a fiberglass mat. Ruberoid' Mop 39.37" (1 meter) ASTM 136164 Smooth surfaced mop applied SBS base or Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid® Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or anchor Smooth 1.5 wide sheet reinforced with a polyester mat. Ruberoid® Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or Plus Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid® HW 25 39.37" (1 meter) ASTM D6163 Smooth surfaced torch applied SBS base or anchor Smooth wide sheet reinforced with a fiberglass mat. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 2 of 27 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Ruberoid® HW 39.37" (1 meter) ASTM D6164 Smooth surfaced torch applied SBS base or anchor Smooth wide sheet reinforced with a polyester mat. GAFGLAS® 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Mineral Surfaced Wide with fiberglass mat. Cap Sheet Tri-Ply® BUR 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Granule Cap Sheet Wide with fiberglass mat. ! • • ! GAFGLAS 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic'ftp sheet rgivofwd '. EnergyCap Wide with fiberglass mat. Cap shy pis factory Mineral Surfaced 'oated with TOPCOAT® Energy�� t : • • • • : Cap Sheet •'Elastoperij Coating. .... . . • • •. • ..... Topcoat' Surface 5 or 55 gallons ASTM D6083 Solvent -based thermoplasticruDer •" • 06:60. Seal SB sealant designed to proteq ape gstore aged roof surfaces and to increase roof fe3ectivit3. . �• ....: • Topcoat 1, 5 or 55 gallons ASTM D6083 Water -based elastomeric eggting ; • • • •; Membrane code '.... • Topcoat® MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer designed to block asphalt bleed -through. Topcoat® FireOutM 5 or 55 gallons Proprietary Low VOC, water based fire barrier coating. Fire Barrier Coating VersaShield® Fire- 12" x 100' rolls ASTM D226 Non -asphaltic, fiberglass reinforced underlayment Resistant Roof and/or fire barrier Deck Protection VersaShield® Solo" 42" roll wide, 100 ASTM D146, Non -asphaltic, fire resistant fiberglass Fire -Resistant Slip ft. D828, D4869, underlayment Sheet D6757 Topcoat® 1, 5 gallons or TAS 139 Solvent -based elastomeric sealant. FlexSealTM 1 qt. tube NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 3 of 27 APPROVED INSULATIONS: TABLE 2 Product Name Product Description EnergyGuard'" Polyiso Polyisocyanurate foam insulation Insulation EnergyGuard T" Tapered Polyisocyanurate foam insulation Polyiso Insulation EnergyGuard'" Ultra Polyiso Glass -faced polyisocyanurate foam insulation Insulation EnergyGuard'" RA Polyiso Polyisocyanurate foam insulation Insulation EnergyGuard'" RA Composite Polyisocyanurate foam insulation with high Polyiso Insulation density fiberboard or permalite EnergyGuard'" RH Polyiso Polyisocyanurate foam insulation Insulation EnergyGuard'" RH Tapered Polyisocyanurate foam insulation Polyiso Insulation EnergyGuard" RN Polyiso Polyisocyanurate foam insulation Insulation EnergyGuardT" Perlite Roof Perlite insulation board Insulation EnergyGuard'" Perlite Recover Perlite recover board Board Securock® Gypsum -Fiber Roof Gypsum board Board Securock® Glass -Mat Roof Glass faced gypsum board Board Structodek® High Density Fiber High density fiberboard Board Roof Insulation DensDeck® Prime Roof Board Gypsum board DensDeck® Roof Board Gypsum board Manufacturer ith Current NOA GAF GAF GAF GAF United States Gypsum Corp. United States Gypsum Corp. Blue Ridge Fiberboard, Inc. Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum LLC NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 4 of 27 APPROVED FASTENERS: TABLE 3 Fastener Product Product Number Name Description 1. Drill-TecT" #12 Fastener Phillips head, modified buttress thread, pinch point, carbon steel fastener for use in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. 2. Drill-TecT" #14 Fastener Truss head, self -drilling, pinch point, high thread fastener for use in steel, wood or concrete decks. 3. Drill-TecT" ASAP 3S Drill-TecT" #12 Fastener with Drill-TecT" 3" Standard Steel Plate. 4. Drill-TecT" 3" Steel Plate Round Galvalume® steel stress plate with reinforcing ribs and recessed for use with Drill-TecT" fasteners. 5. Drill-TecT" 3" Standard Steel Galvalume` coated steel Plate stress plate for use with approved Drill-TecT" fasteners. 6. Drill-TecT" AccuTrac® Flat A2-SS aluminized steel plate Plate for use with Drill-TecT" fasteners. 7. Drill-TecT" AccuTrac' Galvalume® steel plate with Recessed Plate recess for use with Drill- TecT" fasteners. 8. Drill-Tec 3 in. Ribbed Round Galvalume® plated Galvalume Plate (Flat) steel stress plate with reinforcing ribs for use with Drill-TecT" fasteners. Manufacturer Dimensions (With Current NOA) #12 x 8" max. G.At length, #3 • . . ... Y' *see** Phillips head'+.• .. • Y • .' Y++•+Y • .. Y ...... YYYYYY .... . ..... #14x 16" •••••� CFAF•� •••••• max. length;•';'; •� #3 Phillips• head. •••••• See OAF - components 3" Round GAF 3" Round GAF 3" square; GAF .017" thick 3" square; GAF .017" thick 3" Round GAF NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 5 of 27 EVIDENCE SUBMITTED: Test Aj!ency Test Identifier Description Date Factory Mutual Research Corp. 3014547 4470 05/22/03 3029832 4470 05/11/07 3033135 4470 11 /24/08 3034312 4470 •.1wP9/09 3036980 4470 .'. OC9114/09 ""; • 3038278 4470 " " : `•l f/618/11 '. 3040738 4470 j1/l6/l0: 3041769 •��; 4470 .... • OS/26/11: .... 3042887 4470 "••"•` :"M4/11....� 3042905 4470 ••:••: Qlhl0/12••:••` 3046081 4470 "' ,• "02M 3/13-••••• 3046388 4470 :":`: 69/24/12 0. 3047636 4470 :"•0AA08/13:"'"`: ODOA8.AM 4470 •.. • . . Qj/09/99: • • • •: OD I A&AM 4470 '..9?129/94 OY9Q5.AM 4470 04/01/98 l B9A8.AM 4470 09/04/97 2B8A4.AM 4470 07/02/97 3B9Q1.AM 4470 01/08/98 3D4Q2.AM 4470 05/30/97 797-03221-267 4470 09/27/07 797-03825-267 4470 07/21/08 797-10228-267 4470 01/23/15 UL LLC R1306 UL 790 08/21/18 PRI Construction Materials GAF-122-02-01 TAS 139 05/07/06 Technologies, LLC GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-OlRev ASTM D6083 12/16/10 GAF-276-02-02 ASTM D226 11/15/10 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-417-02-01 ASTM C1289 05/28/13 GAF-464-02-01 ASTM C1289 10/22/12 GAF-464-02-01 ASTM C1289 02/06/14 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-549-02-01 TAS 114 08/08/14 GAF-549-02-02 TAS 114 08/08/14 GAF-559-02-01 TAS 117(13) 09/30/14 GAF-559-02-04 ASTM D 1876 10/01/14 GAF-559-02-05 ASTM D 1876 10/15/14 GAF-559-02-06 TAS 114(H) 10/02/14 GAF-559-02-07 ASTM D 903 10/02/14 GAF-559-02-08 ASTM D 903 10/02/14 NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 6 of 27 EVIDENCE SUBMITTED: (CONTINUED) Test AEency Test Identifier Description Date PRI Construction Materials GAF-559-02-09 ASTM D 903 10/02/14 Technologies, LLC GAF-559-02-11 TAS 114 0.0/44/14 GAF-559-02-12 TAS 114: . •, "1"A4/14 GAF-559-02-13 TAS 114 :%0/1S/14 GAF-559-02-14 TAS 114:.'**•' ..... 10/15/14 GAF-559-02-15 TAS 114 .... 10/j 5/14 GAF-559-02-16 TAS 114'.... :eftllS/14 GAF-559-02-18 TAS 1149•:••: 0010/15/14 GAF-559-02-19 TAS 11400 •• •3ZA115 GAF-628-02-01 ASTM C1289':': 0S/31/16 IRT of S. Fl. 02-005 TAS 114: 0 Kit 8/02 02-014 TAS 114 • • . •1Y3/22/02 Trinity I ERD C8500SC.11.07 TAS 117 11/30/07 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 03/31/10 G33470.01.11 ASTM D6164 11/16/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM D6401 06/04/15 G34140.04.11-5-R3 ASTM D4897 06/04/15 G36780.07.11-R1 4470-TAS 114 07/18/11 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D6164 01/07/14 G40630.01.14-2A-1-R1 ASTM D6164 04/10/14 G43610.01.14 ASTM D3909 01/22/14 G6850.08.07-1 ASTM D3909 08/13/07 SC6870.08.14-R1 ASTM D3909 09/04/14 SC9700.08.15-RI ASTM D2178 8/31/2015 SC10680.05.16 ASTM D6163 5/10/2016 SC13105.03.17-R1 ASTM D6164 3/23/2017 Dynatech Engineering Corporation #4482.02.95-1 TAS 114 09/01/95 Atlantic & Caribbean Roof 11-053 TAS 114 08/12/11 Consultants, LLC NOA No.: 18-0919.07 rtIAMI•DADEcouNTr Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 7 of 27 APPROVED ASSEMBLIES Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 19/32"'or greater plywood or wood plank secured 6 in. o.c. at panel endeatx� • intermediate supports with 8d ring shank nails to supports spaced 2.4•ip. o.c.•at ax. • • • •; • System Type A(1): All insulation layers are adhered, to a mechanically attached anek®r aheet. X%Wane is ....... subsequently fully adhered to insulation. • • • • • • 0 0 • ...... All General and System Limitations shall apply. • .... :***so ..... Fire Barrier: Topcoat' FireOue ' Fire Barrier Coating,V ersaShield Fire-Resi • 0.0 0oof DQ 'P • tecti 00000 p ® St�1t.R Gj * �.... (optional) VersaShield' SoloT" Fire -Resistant Slip Sheet, DensDeck® RoofP6"d, Securock4 Glass- .' Mat Roof Board or Securock® Gypsum Fiber Roof Board installed per manufacturer's • • •.. • installation instructions. • • 0 0 0 0 • Anchor sheet: GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS' Stratavent® Nailable Veniiag�ase Sheet or Ruberoid® 20 Smooth mechanically fastened as described below. Fastening GAFGLAS® Ply 4, GAFGLAS® Flex Ply'" 6, GAFGLAS® #75 Base Sheet or any of above Option #1: anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening GAFGLAS® Ply 4, GAFGLAS® F1exPlyT" 6, GAFGLAS® #75 Base Sheet or any of above Option #2: anchor sheets attached to deck with Drill-TecT" #12 Fastener, Drill -Tee " #14 Fastener and Drill-Tec' 3" Steel Plate, Drill-TecT' AccuTrac® Flat Plate or Drill-TecT' AccuTrace Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening GAFGLAS® F1exP1yTM 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of Option #3: above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —52.5 psf. See General Limitation #7) Fastening Any of the above anchor sheets attached to deck with approved 1'/4" annular ring shank nails Option #4: and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecT" Option #5: #12 Fastener, Drill-TecT" #14 Fastener and Drill-TecT" 3" Steel Plate, Drill-Tec", AccuTrace Flat Plate or Drill-TecT" AccuTrac® Recessed Plate 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 8 of 27 Fastening (Continued) Any of above anchor sheets attached to deck approved annular ring shank nails and 3" Option #6: inverted Drill-TecT" insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS' #75 Base Sheet or any of above anchor sheets attaclied W deck avj"ptill-Tep;;.,. Option #7: #12 Fastener or Drill-TecT" #14 Fastener and 3" Drill-TecT" 3" Sloal'Pl'nte, Dsi4l-TecT" AccuTrac' Flat Plate or Drill-TecT" AccuTrac' Recessed Plate 8i'•o.F! in 4 rows •One row i,,p • • in the 2" side lap. The other rows are equally spaced approximarMJ9'''o.c. in thd'field of!.... the sheet. (Maximum Design Pressure —45 psf. See General Limitation #p • • .... . . ..... One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners • Paslener • • • • • • (Table 3) ; ' Wilsity/ft;,. EnergyGuardT" Polyiso Insulation, EnergyGuardT" Ultra Polyiso Insulation, EnergyGua'rd P.H Poi0is'o'. ' .00 Insulation, EnergyGuard'" RA Polyiso Insulation, EnergyGuardT" RA Composite Polyiso Insulation Minimum 1" thick N/A N/A EnergyGuardT" Perlite Recover Board, DensDeck® Prime Roof Board Minimum'/2" thick N/A N/A EnergyGuardT" Perlite Roof Insulation Minimum'/<" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuard`" Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply' #75 Base Sheet, GAFGLAS® #80 UltimaT" Base Sheet, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth or Ruberoid°` 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. applied in accordance with manufacturer's instructions. (see General Limitation #4). OR GAFGLAS® Stratavent' Perforated Venting Base Sheet loose -laid dry (not for use with perlite top layer insulation or composite polyiso top layer insulation). Ply Sheet: One or more plies GAFGLAS' Ply 4, Tri-Ply' Ply 4, GAFGLAS' FlexPlyT. 6 or GAFGLAS' #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS' Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCapT" Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 9 of 27 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat® Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. OR •••� • Topcoat' MB Plus applied at 0.5 to 0.75 al./s to be used as a •riv?e folio• � d � p PP g q•� 13 � lv� �Y • • • • • • • Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. ...... '..' • • • •; • 3. Fiber Aluminum Roof Coating. • • • • • • Maximum Design .... . ..... . Pressure: • • See Fastening Options. • • • � • � � • � • � • • • � • . . .. . ...... NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 10 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(2): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. • • • • . . .... ...... All General and System Limitations shall apply. .. .. • . . Fire Barrier: Topcoat' FireOut" Fire Barrier Coating, VersaShield® Fire-l�essls: j t Slip•She el or (optional) VersaShield' Solo' Fire -Resistant Slip Sheet installed per maprlVturer's inst3jlation � • • • • instructions. 000000 : ""' • • • • • Anchor sheet: GAFGLAS #75 Base Sheet Tri-Ply' #75 Base Sheet Ruber • • • ""' • ® , y® p1�;�8 Smooth e�� •••••• GAFGLAS® Stratavent® Venting Nailable Base Sheet is secutZd SS described pelow. • Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank nails and r;ilra 104/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide aftgb $beet s14g jalps and �• • • • in. o.c. in the field of the sheet in two staggered rows. '....' (Maximum Design Pressure: —45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-Tec'" #14 Fasteners and Drill -Tee " 3 in. Standard Steel Plates, Drill-TecT" Option #3: AccuTrac® Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec" Option #4: AccuTrac® Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-Tec'" #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-Tec'" Option #5: AccuTrac® Flat Plates or Drill-Tec— 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —75 psf. See General Limitation #7) One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard'" Polyiso Insulation, EnergyGuard'" Tapered Polyiso Insulation, EnergyGuard'" Ultra Polyiso Insulation, EnergyGuard"" RH Polyiso Insulation, EnergyGuard'" RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 11 of 27 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard'" Perlite Roof Insulation Minimum'/4" thick N/A N/A Structodek® High Density Fiberboard Roof Insulation Minimum %" thick N/A N/A Securock® Gypsum -Fiber Roof Board, DensDeck® Prime Roof Board ". • • •. • • • Minimum 1/4" thick N/A • • • . • NZ , .' •••••• • •• •••••• Note: All insulation shall be adhered in a full mopping of approved hot asphalt withZehdo E,VT range and at rate of 20-40 lbs./100 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. •••.•• Base Sheet (Optional): GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, RubergX:Q Smooth adhered i�0:00• a full mopping of hot asphalt applied at 20-40 lbs./sq. installed ph, 0anufatt, 0l;j 0.0.0 • installation instructions. • • • • • • 'of. • •• . •...•• Ply Sheet: When optional base sheet and/or cap sheet is present: • • 0 Two or more plies of GAFGLAS Ply 4, Tri-Ply® Ply 4, GAFtib k;�' Flex RIY•6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. When optional base sheet and/or cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet (Optional): GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap" Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1.. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoats' Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.: 18-0919.07 MIAMMAD, couNrr Expiration Date: 11/04/23 I�® Approval Date: 11/08/18 Page 12 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(3): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. • • • • . . .... ...... All General and System Limitations shall apply. .. „ • Fire Barrier: Topcoat® FireOutT" Fire Barrier Coating, VersaShield® Fire-R •ie • rit Slip sheet or ��� (optional) VersaShield® Solo" Fire -Resistant Slip Sheet installed per mar"4rturer's jnstauation ; • • * • instructions. '....' ;""' ...•. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, RubergiX "0 Smoot: v � • • • GAFGLAS® Stratavent® Venting Nailable Base Sheet is secuw"described below.. • Fastening • Miami -Dade County Approved min. 12 ga. annular ring shank7nail sand miV4-344 in. ••"'� Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide ar;� sheet sue•l�ps and • • • • in. o.c. in the field of the sheet in two staggered rows. ',...' (Maximum Design Pressure: —45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-Tec'" #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-TecT" Option #3: AccuTrac® Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-TecT" Option #4: AccuTrac® Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-TecT" Option #5: AccuTrac® Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —75 psf. See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 13 of 27 One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardTM Polyiso Insulation, EnergyGuardTM Tapered Polyiso Insulation, EnergyGuardTM Ultra Polyiso Insulation, EnergyGuardTM RH Polyiso Insulation, EnergyGuardTM RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners F4%t$per (Table 3) Dt"i1f2 • • • • • • • • • . EnergyGuardTM Perlite Roof Insulation • • .. Minimum 1/" thick N/A • • •; • • NlA• .... Structodek® High Density Fiberboard Roof Insulation •... ;""; Minimum '/2" thick N/A • • • • • IV7' . ..... Securock® Gypsum -Fiber Roof Board, DensDeck® Prime Roof Board ' .. .. .. .. ...... Minimum 1/4" thick N/A • • VA . . .. . ...... Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the.EVT r$nAgohd at • rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117 for in*efation attacliment. Base Sheet: Ruberoid' 20 Smooth adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. Cap Sheet: GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat' MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 14 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(4): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. .... ...... Fire Barrier: TOPCOAT FireOut"' Fire Barrier Coating, VersaShield' Fire;$g ; §tant Slap %et or (optional) • • • VersaShield® SoloT" Fire -Resistant Slip Sheet installed per matxAsturer's installation instructions. • • • • Anchor sheet: 41 .... ..... GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, RubergW.jQ Smooth or • � , , • • • GAFGLAS® Stratavent® Venting Nailable Base Sheet is secusecd as $escriBsd Mow. . • . • , • Fastening Miami -Dade County Approved min. 12 ga. annular ring shanjnails and mlrj. ] 5/8 in. Option #1: • diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet s:de WA and , in. o.c. in the field of the sheet in two staggered rows. I..* Sao* ; • • • • ; • (Maximum Design Pressure: —45 psf. See General Limitation #7) • *see Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-Tec'" #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'" Option #3: AccuTrac® Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-Tec" #14 Fasteners and Drill-Tec" 3 in. Standard Steel Plates, Drill-Tec" Option #4: AccuTrac® Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill-Tec" 3 in. Standard Steel Plates, Drill-Tec'" Option #5: AccuTrac® Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —82.5 psf. See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 15 of 27 'Voon ORIDP SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR Kg0tf 1G CONSIDERATIONS • ...... . .. ...... 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractopto•previde the owner with • the required roofing permit, and to explain to the owner the content of the section. The�previsipns of ZQQt�LR4402 govern the minimum requirements and standards of the industry for roofing system instdilattins. Addltionally, the following items should be addressed as part of the agreement between the owner ant thUblilractor.-Ae.owner's • initial in the designated space indicates that the item has been explained. . . .. . .... % 2. Renailing wood decks: When replacing roofing, the existing wd4d boo: deck m*have to b enailed in accordance with the current provisions of Section R4403. (The roof deck is usually* • concealed prior to removing the existing roof system). 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can a viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is n overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scu rs in acc ance with the requirements of Sections R4402, R4403 and R4413. ier/A nt's Si a re Date Contractor Si ature Date Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES - UNIFORM PERMIT APPLICATION Florida Building Code 6th Edition (2017) Im ra High -Velocity Hurricane Zone Uniform Permit Application Form. • • INSTRUCTION PAGE •"• 00 COMPLETE THE NECESSARY SECTIONS OF ." THE UNIFORM ROOFING PERMIT •••••• APPLICATION FORM AND ATTACH THE '•'•.• REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required' See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes I A,B,D 1 1,2,4,5,6,7 Other I As Applicable 1 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation r • • . f .• .. .. •••••• • .. .. •• •• .. .. • •• • .. .. .. .. •••• • • • • 0000 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING 5.31 One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener Density/ft' (Table 3) EnergyGuardT" Polyiso Insulation, EnergyGuardT" Tapered Polyiso Insulation, EnergyGuard'" Ultra Polyiso Insulation, EnergyGuard'" RH Polyiso Insulation, EnergyGuardT" RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ftz. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: GAFGLAS® Stratavent® Perforated Venting Base Sheet is laid dry over the "ation. Ply Sheet: When optional cap sheet is present: 0 • • • • • • • • • • Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFQJA$. FlexplyA ffdhere�..;. in a full mopping of hot asphalt applied at 20-40 lbs./sq. installQdpec manufacturer's installation instructions. • • • • • .... . ..... When optional cap sheet is not present: ": Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAML7AS® Flex7rly•' • adhered in a full mopping of hot asphalt applied at 20-40 lbs./jq. iris lled gerc ....;. manufacturer's installation instructions. Cap Sheet (Optional): GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Shea *or: • GAFGLAS® EnergyCap'" Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 16 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" thick or greater or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(5): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOutT" Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or V erg Shield® 00 (optional) Solo'"' Fire -Resistant Slip Sheet. • . . .... ...... GAFGLAS® #75 Base Sheet Tri-Ply® #75 Base Sheet is descnfiad Ielow • Anchor sheet: or secured as • with Dade County Approved min. 12 ga. galvanized ring shanka.nd 32 a.,•1-5/8 i• • • • • • diameter tin tabs. • • • • • • Fastening: Nails and tabs are spaced 8 in. o.c. in the 4 in. wide side lap ancl•g in. o.c. in two • • • • • ..... ..... . . . staggered rows in the field of the sheet. • • One or more layers of any of the following insulations. : • • : • • • Base Insulation Layer . . .. . Insulation Fasteners • Fastener ...... • • (Table 3) • • • oulSity/ft, 000000 • • EnergyGuard'"' Polyiso Insulation, EnergyGuardT"' Tapered Polyiso Insulation, EnergyGuardT"' RH Polyiso Insulation, EnergyGuardT" RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft Structodek® High Density Fiberboard Roof Insulation, Securock® Gypsum -Fiber Roof Board Minimum'/2" thick N/A IN/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Ply: Two or more plies of GAFGLAS® F1exP1yT" 6 adhered with hot asphalt applied at 20-25 lbs./sq. Cap Ply: GAFGLAS® Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat®MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. Maximum Design Pressure: —52.5 psf. (See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 17 of 27 Membrane Type: BUR Deck Type 11: Wood, Insulated Deck Description: 19/32" or greater thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type C: All layers of insulation are mechanically attached to roof deck. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut'M Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or VersMield® • • • • • • • • • • (optional) Solo'" • Fire -Resistant Slip Sheet. • • . . ...... . .. ...... One or more layers of any of the following insulations. • • •see Base Insulation Layer (Optional) Insulation Fastener9 •*a9tener• • .... . ..... (Table 3) ..... .Density/ft.. %. * EnergyGuard" Polyiso Insulation, EnergyGuardTM RA Polyiso Insulation, EnergyGuard'•'RN Polyiso Ululation • • • • Minimum 1" thick N/A • • • • • • • N/A • • . . •• • ...... Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Intutatidn panels listed are minimum sizes and dimensions; if larger panels are used, the number of.iasteners 9hali be �•.•. increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 4417 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuard'M Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' SECUROCK® Gypsum -Fiber Roof Board Minimum'/4" thick 2,8 1:1.78 ft2 Base Ply: Two or more plies of GAFGLAS® FlexPlyTM 6 adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions. Cap Ply: GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS® EnergyCap'M Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: —60 psf. (See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 18 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type D: All insulation is loose laid with preliminary attachment to roof deck. Anchor sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners •Ftiltener (Table 3) ; flelrisity/ft'* Ener Guard'"' Pol iso Insulation Ener Guard'" Ultra Pol iso Insulation Ener GuardT�RA Poi iso• • gY Y gY Y Insulation Y •0•�•• y.. Minimum 1.3" thick N/A .... N/A Structodek® High Density Fiber Board • "' "' • Minimum 1" thick N/A ":' �: . .. •N;A • • .. .. ....... Note: Insulation shall have preliminary attachment, prior to the installation of the ba"Zoet, at a minimum • application rate of two fasteners per board for insulation boards having no dimension greattr thap•4 ff.,and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of insulation optional• • • • thermal barrier (when present) and base sheet shall be simultaneously fastened. See base sheet bc4i vet r • fasteners and density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Fire Barrier: FireOutT" Fire Barrier Coating, VersaShield' Fire Resistant Roof Deck Protection, (optional) VersaShield® Solo" Fire -Resistant Slip Sheet, DensDeck® Roof Board, Securock" Glass - Mat Roof Board or Securock'" Gypsum Fiber Roof Board. Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS' #80 Ultima'" Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet or Ruberoid® 20 Smooth applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Fastening Drill-Tec" #12 Fastener or Drill-Tec'" #14 Fastener and Drill-TecT" 3" Steel Plate, Drill - Option #1: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec'" AccuTrac® Flat Plate or Drill-Tec'" AccuTrac® Recessed Plate is installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening Drill-Tec" #12 Fastener or Drill-Tec'" #14 Fastener and Drill-Tec'" 3" Steel Plate, Drill - Option #2: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec'" AccuTrac® Flat Plate or Drill-Tec'" AccuTrac® Recessed Plate is installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf. See General Limitation #9) Fastening GAFGLAS® #80 Ultima" Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth Option #3: attached to deck with approved annular ring shank nails with a minimum embedment of 1" into the wood substrate and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) NOA No.: 18-0919.07 MIAMI•DADECOUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 19 of 27 Fastening (Continued) Drill-TecT" #12 Fastener or Drill-TecT" #14 Fastener and Drill-TecT" 3" Steel Plate, Drill - Option #4: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill-TecT" AccuTracl Flat Plate or Drill-TecT" AccuTrac® Recessed Plate in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf. See General Limitation #9) Ply Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply' Ply 4, GAFGLAS® F1exP1yT" 6 or GAFGLAS' #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: Ywww (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet Tr: -Ply BUR Granule • • • •; • Cap Sheet or GAFGLAS®EnergyCapT" Mineral Surfaced Cap Shea adhered:ilk fl>,11 '. mopping of approved asphalt applied within the EVT range and tl alafe of 2640 fbs./sq. • • installed per manufacturer's installation instructions. w.ww.Y • • • • • • Surfacing: weww w w Optional on granular surfaced membranes; required for smodtNfhembAnes. Chosen w components must be applied according to manufacturer's apD!i0allton inst;uetiins. • •„• � � All coatings must be listed within a current NOA. w' • • • • 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in*a flood coal ot• • w • • • • approved asphalt at 60 lbs./sq. '• .0. • • • • • • •' w www ew • w • • w 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. "' • OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.07 MIAMI•DAD, CO� Expiration Date: 11/04/23 NIIIIIIIIIIIIIIIIILMMApproval Date: 11/08/18 Page 20 of 27 Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(1): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOutT" Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck (optional) Protection, VersaShield® Solo'" Fire -Resistant Slip Sheet installed pir manufq6(;turCr's •. 0... installation instructions. ' Base sheet: GAFGLAS® #80 Ultima'" Base Sheet, Stratavent® Nailable Ven *ri3bt* se Sheet,*.Ruberoi4a• •, 20 Smooth, Ruberoid® SBS Heat -Weld' Smooth or Ruberoid® SV�. jIeat-W;ld`;5 base;"•': sheet mechanically fastened to deck as described below; •. Y •. • :'"" 00:0 • Fastening 00000 GAFGLAS® Flex PIy'M 6, GAFGLAS' #75 Rase Sheet, Tri-Ply Base Sh��rQ>:any ofY..•Y Option #1: the above anchor sheets attached to deck with approved annular,rigg bank nails and tin Y • caps at a fastener spacing of 9" o.c. at the 4" lap staggered and it two rows 91'•o.c•in the • • • • : • field. 00 0000 (Maximum Design Pressure —52.5 psf. See General Limitation #'7) "" ' .... Fastening GAFGLAS® #80 Ultima'"' Base Sheet, Ruberoid® 20 Smooth or Ruberoid® Mop Smooth Option #2: attached to deck with approved 1'/a" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf. See General Limitation #7) Ply Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCapT" Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 tbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 21 of 27 Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(2): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOutT" Fire Barrier Coating, VersaShield° Fire Resistant Roof Deck (optional) Protection, VersaShield SoloT" Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. .... Anchor sheet: GAFGLAS® #80 Ultima Base Sheet mechanically attached with 4';ljarmj-Dade.�oupty •. • • Approved min. 1'/4 long, 12 ga., annular ring shank nails and cad s ....:. spaced 7" o.c. in the min 4" wide side laps and in 3 staggered rows.li the field of the sheet. • ...... Ply Sheet: Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGL•tj.$; .?lexPl:r' VaMd'hered IQ... the base sheet in full mopping of approved asphalt applied within ithQ E.VT range nd at a • • : • • • ru rate of 20-401bs./sq. installed per manufacturer's installation instctpns. •• • • • • • • Cap Sheet: One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply© 8UR (;ranuleCap Sheet us..:. GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adhered in : offi11 moppurg of : • • approved asphalt applied within the EVT range and at a rate of 20a40 lbs./sq. �IlMilgd per* • manufacturer's installation instructions. ' • •' Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 22 of 27 Membrane Type: BUR Deck Type H: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(3): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOut'" Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or (optional) VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. .... Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply' 475 Base Sheet, Ruberoid®qPbSmootA or 0 *Go:* • .. • • . GAFGLAS® Stratavent° Venting Nailable Base Sheet is securg��.4escrib�d'l W6w. ....,. Fastening Miami -Dade County Approved min. 12 ga. annular ring shankiiai'and min. 1!5/8 in. • • • • Option #1: • diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor.• sheet siJle4apgand 8.... in. o.c. in the field of the sheet in two staggered rows. ' ...... . ....... (Maximum Design Pressure: —45 psf. See General Limitation #7).' '. ..'. •... • Fastening 000 Miami -Dade County Approved min. 12 ga. annular ring shank bails aid miq..l 5J8 in. • • ••; 6 Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet sidg ltips'and 6 . . in. o.c. in the field of the sheet in two staggered rows. •..' .... • • (Maximum Design Pressure: —52.5 psf. See General Limitation #7) • • • • Fastening Drill-Tec'" #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'" Option #3: AccuTrac' Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-Tec" #14 Fasteners and Drill-Tec" 3 in. Standard Steel Plates, Drill-Tec'" Option #4: AccuTracl Flat Plates or Drill-Tec" 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-Tec'" #14 Fasteners and Drill-Tec" 3 in. Standard Steel Plates, Drill-Tec' Option #5: AccuTrac® Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —97.5 psf. See General Limitation #7) Ply Sheet: When optional cap sheet is present: Two or more plies of GAFGLAS' Ply 4, Tri-Ply' Ply 4, GAFGLAS' Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. When optional cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, Tri-Ply' Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 23 of 27 Cap Sheet: - (Optional) GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCap— Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used asprimer) fo1�1QYv.eby • .a Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. • • ; �. .' .,, ...... . .. ...... 3. Fiber Aluminum Roof Coating. • Maximum Design • • • • ' Pressure: See Fastening Above. "" : • • • ...... . . ..... .. .. .. .. ...... . . .. . ...... NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 24 of 27 Membrane Type: BUR Deck Type 1I: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(4): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOut'" Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet (optional) VersaShield® Solo'" Fire -Resistant Slip Sheet, installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or EiAMCAS® Stratavent® Venting Nailable Base Sheet is secured as described bel;y% • • • • • • • • • • •' • Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails 'hi MArn. 1-5i8 in.•diameter • • • • Option #1: tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side•1Ks nd 8 in. o.c.•in the ; • • • • field of the sheet in two staggered rows. • 0000 • ; • • • • • ..... (Maximum Design Pressure: —45 psf. See General. Limitation #7) ...... ..... Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 irk diameter Option #2: tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side 1Rpsoar4l 6 in..Q.c. in the ....:o field of the sheet in two staggered rows. : 6.6 • • • • • (Maximum Design Pressure: —52.5 psf. See General Limitation #7f • • • ...... Fastening Drill-Tec— #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-Tec'" AccuTrac® Option #3: Flat Plates or Drill -Tee" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-TecT" AccuTrac' Option #4: Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-TecT" AccuTrac® Option #5: Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —97.5 psf. See General Limitation #7) Base Sheet: Ruberoid' 20 Smooth adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: GAFGLAS' Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCap'" Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. , NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 25 of 27 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2 3 Topcoat" Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. Ahimimim Fiher Rnnf Cnntinn . • Maximum Design Pressure: See Fastening Above. .... . ..... ...... . . ..... .. .. .. .. ...... ,..... . . . . .. . ...... .. . .... . .... NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 26 of 27 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply'" 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/4" DensDeckT" Roof Board or'h" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Pr eIiit Control Approval guidelines. All other layers shall be adhered in a full mopping of approved aWhall applie✓!l v 4bfn the ...... EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening Pavtrd of tha 101P IVer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in appso vad asphalt, panel size • • • • • shall be 4' x 4' maximum. • • • • • • • • 4. An overlay and/or recovery board insulation panel is required on all applications over c &?dVrell fol"44ulatior s • when the base sheet is fully mopped. If no recovery board is used the base sheet shall bel ppl fed using spot �! • mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribboos�i"`tree r8Vse, p:e at each sidelap and one down the center of the sheet allowing a continuous area of ventila�pp..Fncircling of the .' strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow crols ventilatiowo Asphalt • • • • • application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems ARM be ;....; limited to a maximum design pressure of -45 psf. • • 0 "***SO 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 207YIbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 27 of 27 - -- GAFTGFU.R1306- UL Product Spec "GAFGLASO #80 UltimaTM Base Sheet" or "GAFGLASO Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent@ Perforated Venting Base Sheet"or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet' or "Tri-Ply® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Membrane: — One or more plies "RUBEROID® Torch Smooth" or "Tri-Ply® APP Smooth" or "Tri-Ply® APP Granule" or "RUBEROIDO Torch Granule" or "RUBEROIDO Torch 180", torch applied or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" or "RUBEROID® Mop Plus Smooth" or "RUBEROID® Mop Granule" or "Intec Flex PRF" or "Tri-Ply® SBS Granule", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet' or GAFGLASO EnergyCapTm Mineral -Surfaced Cap Sheet', fully adhered with hot roofing asphalt 13. Deck: C-15/32 Incline: 1 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) o�••••a "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). •••• ••••:• Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or Qb1 � socyanVrsIAar • • •,;. urethane or pedite/polyisocyanurate composite or perlite/urethane composite or wogs IiPX/polyisoryanurate • composite or phenolic, any thickness. • .... • Base Sheet: —Two or more plies Type G2 "GAFGLASO #75 Base Sheet' or "Tri-Ply@ 5 Base Sheet' dr :•'. "GAFGLAS® #80 UltimaTm Base Sheet"or "GAFGLAS® Stratavent® Nailable VentingsBase Sbbet" br "GAFGLASO Stratavent® Perforated Venting Base Sheet" or Type G3 "GAFGLAS®'MPrtral SuNcM Cap •' • Sheet" or "Tri-Ply® BUR Granule Cap Sheet', mechanically fastened or fully adherecdddlVAot roofing jasphalt • Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS® Ply4" or "Tri-PIA Ply%" or •SLASO •••. Ply Flex 6" or "Tri-Ply® Ultra-Fle),able Ply 6", fully adhered with hot roofing asphalt. • • • • • • Membrane: — One or more plies "RUBEROIDO Torch Smooth" or "T Ply® APP Smooth" or " YrL6 APP • Granule" or "RUBEROIDO Torch Granule" or "RUBEROID® Torch 180", torch applied or "RUBEROIDO Mop Smooth" or "RUBEROID® Mop Smooth 1.5" or "RUBEROID® Mop Plus Smooth" or "RUBEROID® Mop Granule" or "Intec Flex PRF" or "Tri-Ply® SBS Granule", fully adhered with hot roofing asphalt Cap Sheet: — Type G3 "GAFGLASO Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet' or "GAFGLAS® EnergyCapTm Mineral -Surfaced Cap Sheet', fully adhered with hot roofing asphalt 14. eck: C-15/32 Incline: 2 Barrier Board (Optional): — OOne or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTm Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or,glass fiber or poly!socyanurate or pedite/polyisocyanurate composite or wood fiber/polyisocyanurate composite any thickness mechanically or adhered with hot roofing asphalt Base Sheet: — One ply "GAFGLAS® Stratavent® Perforated Venting Base Sheet' or Type G2 "GAFGLAS® #75 Base Sheet"or "Tri-PI)G #75 Base Sheet' or "GAFGLASO #80 UltimaTm Base Sheet' or "GAFGLAS® trataveRWallable Venting Base Sheet' or "GAFGLAS® Stratavent® Perforated Venting Base Sheet', mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet: — Two or more plies Tvr,P C'1 "CA_F �� ,4. ®Plv_4" or "Tri-Ply® Ply 4" or "GAFGLASO Ply Flex 6" or "Tri-Ply® Ultra -Flexible Ply 6" or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" or "RUBEROIDO Mop Plus Smooth", "Ruberoid® 20 Plus Smooth" or "RUBEROID® 20 Smooth", fully adhered with hot roofing asphalt. Me: — Type G3 "Tri-Ply® BUR Granule Cap Sheet' or "GAFGLAS® Mineral Surfaced Cap Sheet' or �YrA GAFGLAS® EnergyCapTm Mineral -Surfaced Cap Sheet', fully adhered Nth hot roofing asphalt 15. Deck: C-15/32 Incline: 1 Insulation (Optional): — Any thickness periite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. roductVec.ul.com/document.php?id=TGFU.R1306 7/85