Loading...
RF-20-17AC132 Engineering Inc. Testing & Engineering Service Certificate of Authorizati # 8131 Tel: 954.245.8976; Fax: 954.3 .7 77 6 5230 NE 18 Avenue, Fort Lauderdale, F 33. A++�m+i.-%r%- Client: Big Al's Roofing Test Date: 01/27/2020 Roof Tile Uplift Test Report IO 4mi Shores Village, Building Department 10050 NE 2nd Ave, Miami Shores, FL 33138 Permit # RF-01-20-17 Property Address: 443 NE 941'' Street, Miami Shores FI Roof Pitch: Type of Tile: Roof Area: 3 in 12 Boral Roof Tile 26.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive -Poly Pro AH 160 Field Instrument : IMADA Force Gauge 0-100 Serial number: 243454 Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: 10.00(T1-T10) 10 As per FBC 2017 Passed Field Area: 16.00(T11-T26) 16 As per FBC 2017 Passed No. of Corner: 9 (T27-T35) 9 As per FBC 2017 Passed Ridge Areas: 176 pcs. T36-T53) 18 As per FBC 2017 Passed Important: These laboratory results can change due to future weather impacts and/or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. Cordially, AC62 ineering Inc. (NOA 09-1005.01) A et4'g-. cevedo, PE FINo:36466 0'((Z7�2D2o. �s ACB2 Engineering Inc. Engineering and Laboratory Services 5230 NE 181 Avenue Fort Lauderdale, Florida 33334 Phone: (954) 245-8976 Fax: (954) 301-7776 34 ZZ 2$ t Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 01/10/2020 Location Address Parcel Number 443 NE 94TH ST, Miami Shores, FL 33138 113206014OS10 Contacts Permit No.: RF-01-20-17 Permit Type: Roof Work Classification: Tile/Flat Permit Status: Approved Expiration: 07/08/2020 Nuview Ira Inc Owner SETH LONG Owner 44394 443 Big Al's Roofing, LLC Contractor Alvaro HERNANDEZ 5812 NE 199 ST, MIAMI, FL 33015 Business: 3057429615 bigalmiami@gmail.com Description: REPLACE TILE ROOF WITH FLAT BORAL Valuation: $ 23,920.00 Inspection Requests: SAXONY-DARK CHARCOAL BLEND 305-762-4949 Total Sq Feet: 2,600.00 Fees Amount Application Fee - Other $50.00 CCF $14.40 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $4.80 Roofing Fee $250.00 Scanning Fee $12.00 Technology Fee $7.50 Total: $346.20 Payments Date Paid Amt Paid Total Fees $346.20 Credit Card 01/06/2020 $50.00 Check# 1916 01/10/2020 $296.20 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent//�� Date January 10, 2020 Page 2 of 2 Miami Shores Village RECEIVED Building Department 6 2020 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY: Tel: (305) 795-2204 Fax: (305) 756-8972 -14 INSPECTION LINE PHONE NUMBER: (305) 762-4949 / FBC 20 BUILDING Master Permit No. V-F 20 - 1-4 PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF [—]CANCELLATION [:]SHOP qq-3/� �F Q(L�CONTRACTOR DRAWINGS JOB ADDRESS: / t/ y I q . I p. rite. Miami Shnrpc County- Miami Dwip 7in- C�� /�4 3 Zo 6 — o N — a.5 i'o Is the Building Historically Designated: Yes NO ✓ Occupancy Type: &. -A- Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder):t y r—r 1 � L-0 (f ($L Phone#: 'l Address: —QQ13 et I 1 ST City: �� 1 Awl J lQ-W—State: PL Zip: Tenant/Lessee Name: Phone#: Email CONTRACTOR: Company Name: i (A Address: f o 31 —C e S N Q 61 City: M ( Pon t Qualifier Name: State Certification or Registration #: 1s O L_LP_- Phone#: 2 % 33l tate: ►. ,, E�Zip: �1 \ ( � �T m Phone#: 305- -7Y2—`1 �O S 308-7 q Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: _Zip: Value of Work for this Permit: $ a Square/Linear rFF000tage of Work: oZ �v 595- Type of Work: ❑ Addition ❑ Alteration ❑ New '5 I •Reyaic/Replace ❑ Demolition Description of Work:,C� 'C�Or ii`I: S tYx nrnry — 1) 0<01 Y_ C h c, ri .o 61 1�1-eivu Specify color of color thru tile: 6 01 ,AL- 38X0 rr 4 02 Fl &T—j lDASK Cho rcoaL Q &n D Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Technology Fee $ Structural Reviews $ Radon Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ Bond $ :0 1 ­4 -2O 2-3 TOTAL FEE NOW DUE $ Z�6 (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. A / The foregoing instrument was acknowledged before me this .2._ day of 20 •Z o by A Loh., who is personally known to me or who has produced ,4-14t-- as Sign at u�JAW FAWAFIVE&WMA M-MMV-20FA W�M.A The foregoing instrument was acknowledged before me this off— day of 20 Xo by gGva.v 4r-^c,no(Q? who is personally known to me or who has produced P'Nzc, as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: MNWOiTOWO NOTARY PUBLIC: ?. .1� kmMbO iCI0d0 r Ism" 10, 2023 OaMli�ioe i 68303086 Sign: Exphs: FsbmM 10, 2023 Print: Q /LrriPrint: Seal: Seal: APPROVED BY " Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) 12/26/2019 Property Search Application - Miami -Dade County OFFICE OFloft Summary Report Generated On : 12/26/2019 Property Information Folio: 206-014-0510 Property Address: NE 94 ST m Shores, FL 33138-2345 FNUVIEW Owner IRA INCH LONG Mailing Address 1650 W AVE UNIT 501 MIAMI BEACH, FL 33139 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Bath: / Half 2 / 2 / 0 Floors 1 — Living Units 1 Actual Area 2,006 Sq.Ft Living Area 1,572 Sq.Ft Adjusted Area 1,777 Sq.Ft Lot Size 12,900 Sq.Ft Year Built 1950 Assessment Information Year 2019 2018 2017 Land Value $386,677 $386,677 $386,677 Building Value $99,157 $99,157 $99,157 XF Value $2,507 $2,525 $2,542 Market Value $488,341 $488,359 $488,376 Assessed Value $488,341 $488,359 $488,376 Benefits Information Benefit Type 2019 2018 2017 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 2 PB 10-37 LOTS 18 & 19 BLK 52 LOT SIZE 100.000 X 129 COC 24315-3676 02 2006 1 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: Sales Information SaleQualification R Book- DescriptionPage07/06/201203-4502 —PreviousgL_ Qual by exam of deed 03/24/20114-2791 Financial inst or"In Lieu of Forclosure" stated15-3676 Sales which ar=q.afifi.d 15-1408 Sales which ar Iff ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) 1 High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) 1 Master Permit No. Process No. 1 Contractor's Name Job Address / 7 /�� (� IsT 1 I ROOF CATEGORY I ❑ Low Slope ❑ Mechanically Fastened Tile Mortar/Adhesive Set Tiles 1 ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 1 ROOF TYPE � 1 ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering - ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) �!—' Steep Sloped Roof AREA (SSF)- (100 otal (SF) 2(,V P 1 1 1 Section B (Roof Plan) 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. RECEIVED I a� L JAN BY: w a o. r MEN MEN ME MEN ME EMMENEM H 1 w ~ > � w CO L) + NVf Do1N5 e)eiS4cra Flpr� �,00F• Cz ❑ l ❑ v < a �' w C� d 7-" Q i FL , RI;7A B_ D1NG CODE — BUILDING, 5th EDITION (2014) 15.37 a l �' 1 1ra Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezcr Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. 0 I 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form 1 1 Section D (Steep Sloped Roof System) 1 ' 1 Roof System Manufacturer: 7-3ppg �C}� F-�R , LLe • 1 Notice of Acceptance Number: Minimum Design Wind Pressures If Applicable (From RAS 127 or Calculations): 1 P1: q? P1: 91- Q _ P1: I -R-t 1 1 1 1 Deck Type: 1 N ' G✓t�od 1 1 Type Underla ment: 1 Roof Slope: Yp Y S%/%TD ZZ(�'/��- `" ���rv`lLo — 12 Insulation: 1 t 1 Fire Barrier: 1 1 Ridge Ven I lion? Fastener Type & Spacing: n"'QOv¢� y '� f o^� s-td •{,� 1 N � 1 Adhesive Type: 1 -e 1 •4-__ Type Cap Sheet: oGft,%i7e 4, �itt,tU✓a.Yc.( 1 Mean Roof Height: �Z Roof Covering: o�> 8 [A�s Type & Size Drip 3 1 Edge: G, 1 1 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39 LIa�! t 1 1 1 111 [ [I Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mi. If the M, values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P1:1 -7 x X.$16 = "- Mg:_742 = M„-1.Ilb Product Approval M, % 8• p (P2: $$(( f x,%.319' = 1'S_'19) - Mg: 7K = M,, t4b.r; Product Approval M, _ �Cl (Plit&L x%.3IS = I'L (tit) - Mg:-7-fo2.= M,,JL-!V Product Approval M,114.9 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval M, M, required Moment Resistance' Mean Roof Height Roof Slope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 `Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for Fwith the values for Fr. if the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1:_ x L _ = _ x w: _ ) - W: x cos (3_ = Fr,- Product Approval F' (P2:_ x L _ = ` x w: _ ) - W: x cos 6 _ = Ff1 Product Approval F (P3:_ x L _ = _ x w: = _) - W: x cos 0 _ = F, Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity M9 Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Ma Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 FLORIDA BUILDING CODE -- BUILDING, 5th EDITION (2014) Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun B, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. • SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. _�Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6.— L Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is notierloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary install overflow scuppers in accordance with the requirements of Sections R44 2, R4403 and 44 3. e Age 's Signature Date Contractor Signatur Da lizL1111P 11-Ks� Property Address 3-S I --sE) Revised on 7/9/2009 LD;07/01/2015; Permit Number I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 I 1 1 I 1 I 1 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for M, with the values from M,. If the M, values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P1:_ x X _ = - Mg: _ = Mr, _ Product Approval M, (P2:_ x?, _ = _) - Mg: = MQ _ Product Approval M, (P3:_ xx _ = _) - Mg: _ = Mr3 _ Product Approval M, Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product ADDroval M. M, required Moment Resistance' Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 'Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P 1:_ x L _ = _ x w: = _) - W: _ x cos 6 _ = Fr, _ Product Approval F' (P2:_ x L _ = _ x w: = ) - W: _ x cos O _ = F2 _ Product Approval F (P3:_ x L _ = _ x w: = _) - W: _ x cos 0 , = Fr3 _ Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 9 Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity M9 Product Approval Attachment Resistance M, Product Approval Required Moment Resistance M9 Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezcr Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: t a 10050 NE 2nd Ave Miami Shores, A 333138 Re: Owner's Name: 5'JE7TK- Property Address: L 13 A/E 9 4 ST Roofing Permit Number: Dear Building Official: certify that I am not required to retrofit the roof to wall connections of my builzejust because: 1: valuation for the structure for purpose of ad valorem taxation is less than 300 000.0 . $ 0 Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 eOition of the Sout Florida Building Code (1994 SFBC) (—)�A -.J 5� cvv�,- A Lv "'i — I o Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of 4 2—t=7 All Notary Public, Sate of Florida at Large -p-' x ��mndoTaNdo _ac y�lion�66,i • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and th - t coW httN oJJ�;3 3 000 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitiga ion. Revised on 5/21/2009 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 ROOF PERMIT REQUIREMENTS 1. PERMIT APPLICATION. (SIGNED AND NOTIREZED BY BOTH OWNER AND CONTRACTOR) 2. OWNERS AFFIDAVIT OF EXEMPTION, F.S. 553.844 3. AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION FOR HURRICANE MITIGATION. 4. PRODUCT APPROVAL. ( 2 SETS) o Front page. o Specific system description. o Specific system limitation. o General system limitations. o Fire Directory Listing Page. 5. DESIGN CALCULATIONS PER CHAPTER 16. OR IF APPLICABLE RAS 127 OR RAS 128. ( 2 SETS) 6. ROOF PERMIT PACKAGE (2 SETS) 7. OWNERS ROOFING CONSIDERATION (REROOFING ONLY) 8. $50 SUBMITTAL FEE. REVISED ON 7/9/09;07/01/2015; 1. 'i 1 ' l,11111 •. MM�IAM I•QADE LZl'11'� MIAMI-DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES RER ( PRODUCT CONTROL SECTION BOARD AND CODE ADMINISTRATION DIVISION 118SW 26 Street, Room 208 M Miami, Florida 33175-2474474 NOTICE OF ACCEPTANCE (NOA) T (786) 315-2590 F (786) 315-2599 www.miamidade.I!ov/econoMV Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY �4 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description BORAL TileSeal 36" x 36' rolls TAS 103 SBS self -adhering asphalt sheet material with a 36" x 72' rolls ASTM D1970 white glass re -enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. Boral Citadel Plus 36" x 72' rolls ASTM D1970 SBS self -adhering asphalt sheet material with a poly film -facer; for use as a mid -ply underlayment in sloped roof assemblies. MANUFACTURIGN LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: Test Agencv Test Identifier Test Name/Report Date PRI Construction Materials OCF-356-02-04 ASTM D1623 07/25/18 Technologies, LLC. OCF-356-02-02 TAS 103 07/24/18 OCF-356-02-01 ASTM D1970 07/26/18 OCF424-02-04 ASTM D1623 07/25/18 OCF-424-02-01 ASTM D1970 07/25/18 OCF424-02-03 TAS 103 07/25/18 Trinity ERD BRLRF-SC16810.11.17 ASTM D 1876 11/28/17 CMIAMIMM= -C NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 1'/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current approval. (Optional): Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. C DADE COUNTY NOA No.: 18-0502.03 ' Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 3 of 4 LIMITATIONS: Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Sea] as shown below MIAMI•DADE COUNTY END OF THIS ACCEPTANCE MIAMI•DADE COUNTY NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 4 of 4 MIAMFDADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall ear a pe he manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. MIAMMADE COUNTY NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 TAS 101 Two component polyurethane foam adhesive PRODUCTS MANUFACTURED BY OTHERS: Dispensing Equipment Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ 401 F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AR-160 shall solely be used with flat, low, & high the profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their the assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # I Nalithm"Isplastkarnant ►addyisaneathTlie) rwhees roquirod) Undorlsymant 1 a 101 Battens o0tiona) U" Ceuru e \ loin y J2 fascia Ewa Closure \�• Nail through plastic cement (when required) Paddy (Banaeth Tpal E thndaelaymant toin.x `• `w �iS i IIn. wld► 'r fattens optional to in 2 inr EM Closure EMN Course i' �— Fascia "" through plastic c (whan raquk*4M paddy lWanoathrrial Underlayntmt .� t0in.a 2 In. wide Battens optional • + Eaw Course Fasca 1 Weephole loin. In. Ewe closure Drip edge Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 nun) x 10" (254 nun) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # Z Nadthrough plastic cement lwhen reaui►edl Paddy {Beneath tlle? Underlaymmt 7 in. r "2In. r- ' Battens Optional 10�' Ea" Maw* Eava course Fascia Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cmz) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cmz) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 nun) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Natl tluougk pLutk cs (when requlred) ►addy I9eneh Ti1.5 Vndwteryiwent i 1 In. T, 8attees"tloeul low e4unx euie � Wwrphdr 1 o in. 2 in. Eawr dotwe t f Drip edge MIAMI•DADE COUNTY .., t 1 High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cmz) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cmz) - 19 (122.6 cmz) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Nail through plastic cement paddy (between tiles) (when requfredl Battens optional • Paddy (undertile) (} Singlepaddy on top of toe �w e x A In. m single paddy on �dal'm� 2 x 4In. tole ascia Caveclosure Flat/Low Profile Tile Hail through plastic cement Single paddy under the {when required) Paddy(between tees) Battens Paddy (under tile) - (optional `. Singlepaddy ontopoltde` x 4 in. 2 x 4 gg �ndle addycm ut -•,�` 10 in. Eave Gosure Eave Course Fascia Medium ProflleTlle CMIAMI-ZTYDADECO r 1. On the eave course only, apply a minimum 2" (50.8 mm.) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the Overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nall through plastic oe 5ingie paddy under the (when re+qulreO Paddylbetweeo tiles) Battens optimal Paddy (under tile) �./ on undeda ;I Ij '4x4in. ax 4 in pddy tan to op of to .4 .w 4 Eave Course Fascia Weephole Eave closure loin.2in. Dripedge High Profile Tile MIAMI•DADE COUNTY ,...• Also apply a 2" (50.8 nun) x 4" (101.6 nun) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm') - 11 (71cm') square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm') - 9 (58.1 cm) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications in contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then Install the tile. Ensure 20 to 25 sq. in. contact area. ��, e IUnderlayment i (motar shown) Fascia Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile MIAMI•DADE COUNTY Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cmz) — 70 (451.6 cmz) square inch adhesive contact with the underside of the pan tile. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cmz) - 25 (161.3 cmz) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 PRI Construction Material COPO-002-02-12 TAS 101 10/12/2016 COPO-002-02-06 TAS 101 10/12/2016 COPO-002-02-05 TAS 101 10/12/2016 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length -I (ft) Width-w (ft) Saxony 900 10.9 1.417 1.08 Slate, Shake & Split Shake Table 2: Aerodynamic Multipliers - X (ft3) Tile a, (ft3) (ft) Profile Batten Application Direct Deck Application Saxony 900 0.291 0.315 Slate, Shake & Split Shake Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Ej12" 4":12" 5":12" 6":12" 7":12" or Profile greater Saxony 900 Deck Battens Direct Bttns Direct Battens Direct BattensDirect Slate, Shake & Deck Deck Deck Deck S lit Shake 62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95 MIAM E ADE COUNTY NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf) for Mechanically Fastened Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Saxony 900 2-10d Rinq Shank Nails 30.9 38.1 17.2 Slate, Shake & Split 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 Shake 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 .#8 Screw 30.8 30.8 18.2 2 .#8 Screws 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field 24.3 24.3 24.2 Clip) 1-10d Smooth or Screw Shank Nail (Eave 19.0 19.0 22.1 Clip) 2-10d Smooth or Screw Shank Nails (Field 35.5 35.5 34.8 Clip) 2-10d Smooth or Screw Shank Nails( ave 31.9 31.9 322 Clip) Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Saxony 900 Slate, Shake & Split Shake Adhesive' 31.3 2 a 3 594 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBond' one -component foam minimum weight per paddy 13.9 grams. 3. ICP Adhesives Polyset® AH-160 two -component foam, minimum weight per paddy 8 grams. 4. DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake ICP Adhesives Polyset® AH-160 H Two -component foam DAP Products Touch N' Seal Storm Bond 2 two -component foam 3 Large paddy placement of 45 grams of Polyset® AH-160. - 118.9 3 40.4 4 93 5 45 6 4 Medium paddy placement of 24 grams of Polyset® AH-160. 5 Large paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 45 grams. 6 Medium paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 24 grams. APPR04ED NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 5 of 9 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Tile Minimum Attachment Profile Application Resistance Saxony 900 Slate, Shake & Split Shake Mortar Sets 43.96 7 Tile-Tite Roof Tile Mortar 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS QL•., ' • � • .1,Ti� APPROVED NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 6 of 9 NAIL HOLES 12 APPROVED UNDERLOCK SAXONY 900 - SLATE 5/32" (Slate) COVERLOCK NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 7 of 9 PROFILE DRAWINGS NAIL HOLES 1-9/32" (Shake) Note: Available Top Surface Finishes 5. Complete tile brushed 6. Right half brushed (shown in drawing) 7. Left half brushed 8. No brush SAXONY 900 - SPLIT SHAKE MIAMMADE COUNTY NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 8 of 9 NAIL HOLES 1V PROFILE DRAWINGS SAXONY 900- SHAKE END OF THIS ACCEPTANCE 1-9/32" (Shake) MIAMI•DADE C-� NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 9 of 9 MIAMI•DiADE 6-AWAUM MIAMI-DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.I1ov/economv Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This NOA revises NOA No.16-0711.05 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino a MIAMI•DADE C0- NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood SCOPE This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Saxony 900-Slate Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-5/32" batten, mortar set or adhesive set applications. Saxony 900 Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Split Shake Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Top surface produced with 4 different configurations: 1. Complete tile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush Saxony 900-Shake Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete roof Width: varies pieces for use at hips, ridges and rakes. varying thickness NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 2 of 9 2.1 MANUFACTURING LOCATION 2.1.1 Lake Wales, FL 2.2 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 94-060A Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 25-7183-6 Static Uplift Testing TAS 102 Feb. 1995 Engineering, Inc. (2 Quik-Drive Screws, Direct Deck) The Center for Applied 25-7183-5 Static Uplift Testing TAS 102 Feb. 1995 Engineering, Inc. (2 Quik-Drive Screws, Battens) The Center for Applied 25-7214-1 Static Uplift Testing TAS 102 March, 1995 Engineering, Inc. (1 Quik-Drive Screw, Direct Deck) The Center for Applied 25-7214-5 Static Uplift Testing TAS 102 March, 1995 Engineering, Inc. (1 Quik-Drive Screw, Battens) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC-77 TAS 100 Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II & III TAS 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 Redland Technologies P0402 TAS 108 (Mortar Set) Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Atlanta Testing & R1.894/R2.894/R3.894 Physical Properties Aug. 1994 Engineering, Inc. TAS 112 Celotex Corporation 520109-1 Static Uplift Testing Dec. 1998 Testing Service 520111-4 TAS 101 Celotex Corporation 520191-1 Static Uplift Testing March 1999 Testing Service TAS 101 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584/25-7804b-8/25-7804-4 & 5 December 1996 Walker Engineering, Inc. Evaluation Calculations 25-7848-6 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations Restoring Moments Due to Gravity 09/01/16 American Test Lab of RT0617.04-16 TAS 112 06/29/16 South Florida MIAMI•DADE COU- NOA No.: 18-0509.17 ���� ' ' ' ' • ' �3 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 3 of 9