Loading...
RF-19-97Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit No.: RF-01-19-97 Permit Type: Roof Work Classification: Tile Permit Status, Approved Issue Date:01/15/2019 Expiration: 07/15/2019 Location Address Parcel Number 74 NE 97TH ST, Miami Shores, FL 33138 1132060130750 Contacts JOLYON & BERNICE MORRIS Owner GROUP II INC Contractor 74 NE 97 ST, MIAMI SHORES, FL 33138 CARLOS VALDERRAMA 6465 SW 8 ST, MIAMI, 33144 Mobile: 7862518190 Home: 7866215576 Description: RE ROOF TILE Valuation: $ 13,000.00 Inspection Requests: TotalSq Feet: 2,550.00 Fees Amount Application Fee - Other $50.00 CCF $7.80 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $2.60 Roofing Fee $250.00 Scanning Fee $9.00 Technology Fee $7.50 Total: $334.40 Building Department Copy Payments Date Paid Amt Paid Total Fees $334.40 Credit Card 01/15/2019 $334.40 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, 1 authorize the above named contractoE_U2,do the work stated. Authorized Signature: Owner / Applicant / Contractor Date January 15, 2019 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax. (305) 156-8-71 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑N ROOFING ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: 74 NE 97 St RECEIVED JAN 15 f201"9 ��I FBC 20 R- Master Permit Nou. T- � 9 — 01 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS City: Miami Shores County: Miami Dade zip: 33138 Folio/Parcel#: 11 -3206-013-0750 Is the Building Historically Designated: Yes NO X Occupancy Type: SF Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): JOlyon W Morris Phone#: 305-775-7686 Address: 74 NE 97 St City: Miami Shores State: FL Zip: 33138 Tenant/Lessee Name: n/a Phone#: Email: CONTRACTOR: Company Name: Group II, Inc Phone#: 786-621-5576 nr��rPcc 6465 SW 8 St City: Miami State: FL zip: 33144 Qualifier Name: Carlos A Valderrama Phone#: 786-621-5576 State Certification or Registration #: CCCO57129 Certificate of Competency #: n/a DESIGNER: Architect/Engineer: n/a Phone#: Value of Work for this Permit: Type of Work: ❑ Addition Description of Work: Reroof City: State: Zip:: Square/Linear Footage of Work: zs—M N ❑ Alteration ❑ New 0 Repair/Replace ❑ Demolition Specify color of color thru the: Submittal Fee $ Scanning Fee $ Permit Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ (Revised02/24/2014) TOTAL FEE NOW DUE S Bonding Company's Name (if applicable) Bonding Company's Address City n/a State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City unknown State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved andf reinspection fee will be charged. Signature �/l -' Signature ( pp NE*D ENT COT CTOR The foregoing instrument was acknowledged before me this 1Oth day of January Jolyon W Morris me or who has produced n/a 20 19 , by who is personally known to identification and who did take an oath. NOTARY PUBLIC: as The foregoing instrument was acknowledged before me this 1 Oth day of January Carlos A Valderrama me or who has produced n/a 20 19 , by who is personally known to identification and who did take an oath. NOTARY PUBLIC: Print: Day a Aar D° IJ IU Print: day aQffAW FIN LA PU Seal: hPkW 3 iQ= Seal: 4&�* 6 kftK 3�lmt2 BWM ftu Anal Mt>V� Boa" #=Atoll IIIO " as ssssss*sssss*sssss*ss*sssssrs* sssss.ssssssrssssssss*ssssss*s*ssssssssss*sssss*sss*ss*s*s*sssss*sss*ssssssss APPROVED BY �S t Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) 1/15/2019 Property Search Application - Miami -Dade County OFFICE THE PRO Summary Report Property Information Folio: 11-3206-013-0750 Property Address: 74 NE 97 ST Miami Shores, FL 33138-2331 Owner JOLYON W MORRIS BERNICE F MORRIS Mailing Address 74 NE 97 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/3/0 Floors 2 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,700 Sq.Ft Lot Size 8,625 Sq.Ft Year Built 1939 Assessment Information Year 2018 2017 2016 Land Value $215,711 $215,711 $215,711 Building Value $220,794 $220,984 $221,175 XF Value $2,132 $2,150 $2,168 Market Value $438,637 $438,845 $439,054 Assessed Value $438,637 $438,8451 $439,054 Benefits Information Benefit Type 2018 2017 2016 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption 1 $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). (Short Legal Description I MIAMI SHORES SEC 1 AMD PB 10-70 LOT 3 & W1/2 LOT 2 BLK 6 LOT SIZE 75.000 X 115 OR 19035-3770 03 2000 1 COC 24361-4246 03 2006 1 Generated On : 1/15/2019 2017 Aerial Photography 200ft Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $388,637 $388,845 $389,054 School Board Exemption Value 1 $25,000 $25,000 $25,000 Taxable Value $413,637 $413,845 $414,054 City Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $388,637 $388,845 $389,054 Regional Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $388,637 $388,845 $389,054 Sales Information Previous OR Book- Price Qualification Description Sale Page 07/23/2015 $100 29710-2635 Corrective, tax or QCD; min consideration 10/10/2014 $555,000 29367-4939 Qual by exam of deed 12/05/2011 $292,300 28080-3766 Financial inst or "In Lieu of Forclosure" stated 03/01/2006 $808,000 24361-4246 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disciaimer.asp Version To Re: Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR ExiSTINGiITli= BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES ...... ; • • •' • PERSUANT TO SECTION 553.844 F.S. Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, A 33138 ...... ..... Aate:• 1/10 ChU ...... . . . . ...... Owner's Name: Jolyon W Morris .000 ... Property Address: 74 NE 97 St, Miami Shores, FL 33138 Roofing Permit Number: Dear Building Official: I Jolyon W Morris certify that I am not required to retrofit the roof to wall connections of my building because: X The just valuation for the structure for purpose of ad valorem taxation is less than $300,000,00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994,edition olthe South Florida Building Code (1994 SFBC) Jolyon W Morris Signatufe Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this loth day of January, 2019 Dann De V Pit � rr�oo�nbaion;iflQ?AG1iT Notary Public, Sate of Florida at Large S/Z Bwftlft Axonft" • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 OWNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. 1/10/2019 To: Miami -Dade County Building & Neighborhood Compliance Department 11805 Coral Way, Suite 1 I 1 0000 Miami, FL 33175 . . .... ...... Re: Owner's Name Iolyon W Morns ...... ...... Property Address 74 NE 97 St, Miami Shores, FL 33138 ' .... • 660066 . ... ...... .. .... . . . . . . .. .. .. . ...... Roofing Permit Number . . ...... . . ...... Dear Building Official: . Jolyon W Morris 00.0 "' • •' I certify that I am not required to retrofit the reef•to wall connections of my building because: HThe just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. UThe building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subscribed before me this loth day of January , 2019 , (SEAL) QP �Ds laPit E�x 3/ X Personally known BORE Ar01y or Produced Identification When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC, and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided. 5 it SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. Thg provjsions 0jjtion R4402 • govern the minimum requirements and standards of the industry for roofing system ingWIAti4ns. Additionally, the , • following items should be addressed as part of the agreement between the owner ant tbecoatractot'M6wner's...;. initial in the designated space indicates that the item has been explained. • • •. •. . .... . ..... 2. Renailing wood decks: When replacing roofing, the existing wood goof deckfni�llave to"'' .. .. .. . ...... be r ail in accordance with the current provisions of Section R4403. (Thg * * jigck is usually conceale prior to removing the existing roof system). • • • . . 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the;eddecking ca be viewed from below. The owner may wish to maintain the architectural appearance; therefore, ropfing nail penetration of the underside of the decking may not be acceptable. This provides the option of irlta g the appearance. i 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow ajerift scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. Signature Date Contractor Signature Date 7 0E 97 St, Miami Shores, FL 33138 'Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number OA ROOF ASSEMBLIES AND ROOFTOP STRUCTURES b fiF/orlda'Bullding Code Sih Edition (2014) r` High -Velocity Hurricane Zone Uniform Permit Application Form. - _ Section A (General Information) Mans r it No. _ Process No. 4 w rs Name Group II, Inc ob A f ss 74 NE 97 St, Miami Shores, FL 33138 ' • • , 1 ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile IX Mort%f"Wsive SiPTAt. . • • ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wodtf 4"AQles/Shaltesr •; • • • • 1 RECEIVED ❑ Prescriptive BUR-RAS 150 • • • • • • • • • • : S ROOF TYk • • JAN 15- Z919 §[ New roof ❑ Repair ❑ Maintenance ❑ Reroofing : . • • ❑ Recovering ;... •; ' Q ROOF SYSTEM INFORMATION 41 • .... 1 Low Slope Roof Area (SF) 1 Steep Sloped Roof AREA, (SSF)= Total (SF)!Zr� A9rV 1 1 Section B (Roof Plan) 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 I 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 ' 1 a FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Capynalu to. a ik..d by. ICC (ALL RIGHTS RESERVED); accessed by Mora Palado on Jan $. 2015 10'•3202 AM pursuant to Umse Agwemano,►hvtuwhe� t�e�nfMfndwtyxlltMKlSdti- ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Sth Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: 1 Notice of Acceptance Number. 1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): ; P1: P1: P1: • • • •����• . •.i... Deck Type: 5/8" CDX Plywood "" 0...... 1 0000 Type Undedayment: ASTM #30 Felt .... • • • • • • • • • • x • • Roof Slope: 1 0 • 3 12 • Insulation: n/a �..... • 00 •• ... Fire Barrier: n/a 0000 1 1 Ridge Ventilation? Fastener Type & Spacing: 1-1/4" RS Coil Nails 1 1 Adhesive Type: Hot Asphalt 1 1 Type Cap Sheet: Tile Underlayment 1 1 1 Mean Roof Height: 12' Roof Covering: lat Concrete Tile w/ Med Pad y 1 1 Type & Size Drip 3"x3" Galv 1 Edge: 1 1 1 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39 Copyright to, or liccnscd by. ICC (ALL RIGHTS RESERVED): accessed by Mieur Pslaoio on Jun 8, 2013 10:32;12 AM pursuant to Ucensc A4namewt, No fwther repreMietionr aud+ee�d. 1 1 1 1 t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from K. If the M, values are greater than or equal to the M, values, for each area of the roof, then the the attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" e e e • (P1: 39.1 x 7, .313 =-12.24) - Mg:8.03 = Mrt -4.21 Product Approval M, -40.4 .0. e e a e (P2. 68.1 xX .313 =-21.32) - Mg: 8.03 = M(2-13.29 Product Approval Mf -40.400 :0 e 0: s (P3:100.7x?..313 = 31.52 ) - Mg: 8.03 = M� -23.49 product Approval M, _ Method 2 "Simplified Tile Calculations Per Table Below" • • :.. a :. ease Required Moment of Resistance (Mr) From Table Below Product ADDroval M. M, required Moment Resistance' .. .. Mean Roof Height Roof Slope 15' 20' 25' 30' . :40' e 2:12 34.4 36.5 38.2 39.7 ; `¢2.2 • 3:12 32.2 34.4 36.0 37.4 S9.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 e `Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3_ Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the the attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1:_ x L = x w: _ ) - W: x cos 0 _ = F„ Product Approval F' (P2:_ x L = x w: = ) - W: x cos A _ = Fn Product Approval F (P3:_ x L = x w: = _) - W: x cos 0 = F� _ Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity M9 Product Approval Attachment Resistance M, Product Approval Required Moment Resistance M9 Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. .see so e a a ease.* sees.. e e e e a eeaee aeeesa a4, eeeeea e .ease. e 15.40 FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) Copyright to, or licensed by, [CC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No hurter repFoduetions. aethewcea. M IAMI-DIACfE ® PRODUCT COUNTY CT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/sera Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 .... . . .... ...... SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of c8AAMction materials. The • • • • documentation submitted has been reviewed and accepted by Miami -Dade County PERA - go * Control Section.... to be used in Miami Dade County and other areas where allowed by the Authority Having1psetction f ri AMJ3 . • • • • • . This NOA shall not be valid after the expiration date stated below. The Miami -Dade Couloy1wduct fttrotSection • • • ...... (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserva tha siPt to have this • • product or material tested for quality assurance purposes. If this product or material fails to perform inothe accepted...:. manner, the manufacturer will incur the expense of such testing and the AHJ may immediJte1y'rpvoke:modi1?y, or • suspend the use of such product or material within their jurisdiction. PERA reserves the riOt to revo* 09. • acceptance, if it is determined by Miami -Dade County Product Control Section that this product or matenaCfails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA407-0711.03 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0222.03 MIAMW3ADECOUNTYM Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 1 of 8 ROOFING ASSEMBLY APPROVAL Category Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Saxony 900 (Shake, Slate & Split Shake) Concrete -Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL. and described. this NotiM-bf Acceptance. For locations where the pressure requirements, as determined by aVelicable Bbi"Og Code does not exceed the design pressure values obtained by calculations in c0ig1l4qce with RAS 127 using the values listed in the installation section herein. The attachment calculations $half pe done as a moment based system.. ****so • 2. PRODUCT DESCRIPTION Manufactured by Applicant Saxony 900 Trim Pieces Dimensions 1=17" w = 13" 1-5/32" thick Slate 1-9/32" thick Shake & Split Shake Test Pro;uct ; •, •: • Specifications Desc&i I TAS 112 Flat profile, interlocking, high-*.:..* pressure extruded concrete roof tile equipped with two nail holes. For direct deck or battened nail -on, mortar set or adhesive set applications. Length: varies TAS-112 Accessory trim, boosted Barcelona, Width: varies concrete roof pieces for use at hips, varying thickness rakes, ridges and valley terminations manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL. 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 94-060A Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) NOA No.: 12-0222.03 MIAMMADECOUNTY Expiration Date: 04/26/17 C Approval Date: 04/19/12 Page 2 of 8 The Center for Applied 25-7183-6 Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 (2 Quik-Drive Screws, Direct Deck) The Center for Applied 25-7183-5 Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 (2 Quik-Drive Screws, Battens) The Center for Applied 25-7214-1 Static Uplift Testing March, 10.%% Engineering, Inc. TAS 102'000 "•' (1 Quik-Drive Screw, Direct • • • �; • Deck) """ ' The Center for Applied 25-7214-5 Static Uplift Testing . ...March,1991 Engineering, Inc. TAS 102 • • • • • • (I Quik-Drive Screw, ••;••; .• ;•; Battens) .. •• of • Redland Technologies 7161-03 Wind Tunnel Testing : * bec. L991. Appendix II TAS 108 (Nail -On) ; . • • • Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing 0 • Aug. $q� • 1994 TAS 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC-77 TAS 100 Atlanta Testing & Engineering, R1.894 Physical Properties Aug. 1994 Inc. R2.894 TAS 112 R3.894 Celotex Corporation Testing 520109-1 Static Uplift Testing Dec. 1998 Service 520111-4 TAS 101 Celotex Corporation Testing 520191-1 Static Uplift Testing March 1999 Service TAS 101 Walker Engineering, Inc. Evaluation 25-7094 February 1996 Calculations Walker Engineering, Inc. Evaluation 25-7496 April 1996 Calculations Walker Engineering, Inc. Evaluation 25-7584 December 1996 Calculations 25-7804b-8 25-78044 & 5 25-7848-6 NOA No.: 12-0222.03 M"MADECOUNTY Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 3 of 8 Walker Engineering, Inc. Evaluation 25-7183 March 1995 Calculations Walker Engineering, Inc. Evaluation Aerodynamic Multipliers January 2007 Calculations Walker Engineering, Inc. Calculations Two Patty Adhesive Set April 1999 System Walker Engineering, Inc. Evaluation Restoring Moments Due to February 2007 Calculations Gravity Nutting Engineers 130 TAS 112 January 2007 3. LINIITATIONS ' 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set the applications, a static field uplift test sUalf 6e performed in accordance with TAS 106. """ 3.3 Applicant shall retain the services of a Miami -Dade County Certified Lahwtory to pe*vn quarterly test in accordance with TAS 112, appendix `A'. Such testing- all.6e subi»idb&to the Building Code Compliance Office for review. • • • •' • • 3.4 Minimum underlayments shall be in compliance with the applicable Roofrrf+g Ap0gX1gns Standards listed section 4.1 herein. • 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof ;lope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-1 (ft) Width-w (ft) Saxony 900 Slate, Shake & Split Shake 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - X (ft) Tile X (ft) (fts) Profile Batten Application Direct Deck Application Monieri-ifetile Saxony 900 0.289 0.313 Slate, Shake & Split Shake NOA No.: 12-0222.03 rxL MMADe couwrir Expiration Date: 04/26/17 ' Approval Date: 04/19/12 Page 4 of 8 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or Profile greater Saxony 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.16 8.12 7.08 8.03 6.97 7.91 6.82 7.74 6.65 7.55 6.46 7.34 Slate, Shake & Split Shake ••• Table 4: Attachment Resistance Expressed as a Moment - Mf (ftlbf) for Nail -On Systems : • 0 • Tile Fastener Type Direct Deck Direct {beak Battens Profile (min 15132" (min. a9132:' :...:* plywood) plywoR.� • • • Saxony 900 Slate, Shake & 2-10d Ring Shank Nails 30.9 36A • • 4 .2 • 1-10d Smooth or Screw Shank Nail 7.3 98 • • • • 4.0 2-10d Smooth or Screw Shank Nails 14.0 18.8 e 7.4• Split Shake 1 48 Screw 30.8 30.8 • 18.2 2 48 Screws 51.7 51.7 • 4'4 1-10d Smooth or Screw Shank Nail 24.3 24.3 2ti'2 Field Clip) 1-10d Smooth or Screw Shank Nail 19.0 19.0 22.1 Eave Clip) 2-10d Smooth or Screw Shank Nails 35.5 35.5 34.8 Field Clip) 2-10d Smooth or Screw Shank Nails 31.9 31.9 32.2 Eave Clip) Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance MonierLifetile Saxony 900 Adhesive 31.3 Slate, Shake & Split Shake 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. APPROVED J NOA No.: 12-0222.03 Expiration Date: 04/26/.17 Approval Date: 04/19/12 Page 5 of 8 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monierl-ifetile Saxony 900 Slate, Shake & Split Shake Polyfoam Pol ProTm Polyfoam Pol ProTm 40.4 3 Large paddy placement of 45 grams of Pol ProTm. 4 Medium paddy placement of 24 grams of Pol ProTm. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) ."". • for Mortar Set Systems Tile Tile AttswAgient ; • • • • • Profile Application Resistance Monierl-ifetile Saxony 900 Mortar Set • •48,9 ; • •; • Slate, Shake & Split Shake 5. Tile-Tite Roof Tile Mortar ' 5. LABELING : • • • : • 5.1 All tiles shall bear the imprint or identifiable marking of the manufacttira?s name or logo as detailed below, or following statement: "Miami -Dade County Product Control Appro+u 111 LABEL FOR SAXONY 900 TILE (LAKE WALES FL PLANT LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-0222.03 MIAMMOME COUNTY11111 Expiration Date: 04/26/17 �LWA• Approval Date: 04/19/12 Page 6 of 8 NAIL F u PROFILE DRAWING WATERLOCK SAXONY 900 CONCRETE ROOF TILE (SLATE MODEL) 5/32 " (slate) 9/32 " 4s4ake) ERLAY MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SPLIT SHAKE MODEL) NOA No.: 12-0222.03 MIAMI GR1DE COUNTY Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 7 of 8 • •••• • • •••••• ••••• •••••• • ••• ••••• •• •• •••••• ••• •• • ••••• • • • • • MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SHAKEIVIOQEL) ; ... • • • • • • • • • • •••••• • . . . .1100 END OF THIS ACCEPTANCE • 0000 NOA No.: 12-0222.03 MIAMMADECOUNTY Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 8 of 8 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (796) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.mismidade.gov/buildina/ Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 SCOPE: .... This NOA is being issued under the applicable rules and regulations governing the use -of construction tnaterialso.. • The documentation submitted has been reviewed and accepted by Miami -Dade County ONC- Prodypt Control - Section to be used in Miami Dade County and other areas where allowed by the AuthdMtighving Jurisdiction • • • • • • (AHJ)- ...... This NOA shall not be valid after the expiration date stated below. The Miami -Dade C+oun Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade CocU 5 Teserve tlitiht to:::::. ...... have this product or material tested for quality assurance purposes. If this product or warrUl fails to perform . • in the accepted manner, the manufacturer will incur the expense of such testMg 'arid the. AHJ may.... % immediately revoke, modify, or suspend the use of such product or material within theig jurisdic�ton. )3NC; . . . .; reserves the right to revoke this acceptance, if it is determined by Miami -Dade Cddnty Product *Control • • Section that this product or material fails to meet the requirements of the applicable building code. "" This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: PoIypro® AU160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 06-0201.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 11-0124.04 MUW414 ADE COUMV Expiration Date: 05110tI2 ... , Zj Approval Date: 04/14/11 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof the adhesive Materials: Polyurethane SCOPE: This approves Polypro® AH160 as manufactured by Polyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations arc done is. a.. • .... • . moment based system for single patty placement, and as an uplift based system for dedebre pattx� �r� ms •••••• • •••••• PRODUCTS MANUFACTURED BY APPLICANT: "" 0 ' :....: Product Dimensions Test Product'Dest4otioa00000 :.*So ��+00000 • • SWCi$cations • • : • • : • • : • : • • • • • PolyproO AH160 N/A TAS 101 Two component DblYufiethane Mant adhesive • . . . . ...... Foampro® RTFI000 N/A Dispensing Equipment- :""' •• • • •• • • ProPack® 30 & 100 N/A Dispensing Equipment '.%.' PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of Polypro AH160 roof file adhesive. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbsJft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 LbsJFe 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @I58'F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 2 of 7 EVIDENCE SUBMITTED: Test eney Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services LINWATIONS: Test Identifier #94-060 257818-1 PA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[l] 7050.02.96-1 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 ASTM D 1623 ASTM E 108 ASTM E 108 ASTM E 84 TAS 114 TAS 101 TAS 101 TAS 101 ..... ..... Date 04/08/94 12/16/96 10/25/95 11/02/95 12/12/95 02/01/94 04/30/93. ...... 11/16/94 O1AWS% 03/14J90�. . . 10/23/98 12/"l8/98' . .... 03/02/99 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Polypro® AH160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Polypro® AH160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their the assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F _W 2 F'= MS NOA No.: 11-0124.04 MuuHFo�oa Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 3 of 7 INSTALLATION: 1. Polypro® AH 160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH160. 2. Polypro® AH160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tle assembly's adhesive attachment with the use of Polypro® AH160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. Polypro® AH 160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AH160 Operating Instruction and Maintenance Booklet. • • • • 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and Keensed by;>r9V9am Products, Inc. Polyfoam Products Inc, shall supply a list of approved applicatbN (d the authority having jurisdiction. • • • • • • • 5. Calibration of the Foampro® dispensing equipment is required before appliAgQ pf any idlheAve. The mix ratio between the "A" component and the "B" component shall be meiatWued betwepp.1.0- 1.15 (A): 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 poands per tit€ fc' determined at calibration. No other settings shall be approved. • • • • • • • 6. Polypro® AH160 shall be applied with Foampro RTF1000 or ProPack® 30 dt 100 tlisperWpg; • equipment only. • 7. Polypro® AH 160 shall not be exposed permanently to sunlight. • 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® AH160 has been dispensed. 9. Polypro® AH160 placement and minimum patty weight shall be in accordance with the'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Single Paddy Weight Min. rams Two Paddy Weight per paddy Min. rams Flat, Low, High Profiles #1 35 N/A High Profile (2 Piece Barrel) #1 I 17/side on cap and 34/ an N/A Flat, Low, High Profiles #2 24 N/A Flat, Low, HighProfiles4 #3 8 LABELING: All Polypro® AH160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 11-0124.04 MtaMFo�aoe cotmrY Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 4 of 7 ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY P&O (Benuth Tb) Ud srkywl m 1 In. in. EmC4ffm • Fetch Undedapeent I 71n. Vw, 12 In. Asbh� qft EA" Coarse Peddy(BentATle) 0 0 a Goo Fate; 0 waqws: 0 48 dosum NOA No.: 11-0124.04 Expiration Date: 05/10/12 MIAM,ft .RECOUNTY Approval Date: 04/14/11 •Page 6 of 7 ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY IN through Pluft comot Urmspeent • 1 EmCw" • Fasch course oxv: Keep edhosks sppm Em Cotime 4 [a up from W"Ies Ti—,m= 21" EmCmm • Keep adhal" mmm upfmmweeplaNs Paddy (BVM% Tr*) 0 0 0 e fol4 Piece mottoOPIA1 W o sdhnln to Umm v to 23 d"Poftape 9 0 0* piesibris squors kda In cooled wOh the pan t1b 91 P 2)Tutu ,, upside down. PINCOMR101 to la To I In. Frm birlsids adp of omT Me!e Then WW the 119. Underkyrnont lop"Am oftbeem Comemile, Abut buaW course of DO" pin Ike. Emm em awl d Pa" Nmbr pensodcoverMossre on IN Rush it OM Iles. Emelosure w"Upbole Fadal NOA No.: 11-0124.04 WMAMMADE COUNTY Expiration Date: 05/10112 Approval Date: 04/14/11 mj� Page 5 of 7 ADHESIVE PLACEMENT DETAIL 3 DOUBLE PATTY Nall through plastic cement Paddy Nall through plastic cement Single paddy under file (between 919) UrderiRyment Single paddy between tile Paddy 2 In. x 7 In. medium • (under 019) site paddy am course only • Single Paddy n.x 3 In. see under file• ------ x3i 4 In. 2 In. Single Pat 4 In. Single ngle paddy on 2 in. under • paddy on layment under - *Soo*@ Single paddy•Fascla courts an top of file Weep" alkh'. Em Single paddy 11. X 7 In. medium qaffifth� cour" va closure on top of the min paddy am Dflp edge Fmla course only A Nall through plastic cement Single paddy under the Single paddy between the AM- 171 In.x 3 In. 4 In. Single paddy on underlsyment 2 n. Single paddy Eave Cluum on top of the In. x 7 In. medium sin paddy em course only Eve CourseFascia I - END OF THIS ACCEPTANCE NOA No.: 11-0124.04 Expiration Date: 05/10/12 Approval Date: 04/14/11 Page 7 of 7 AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. 11/04/2019 To: Miami -Dade County Building Official 11805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name Iolyon W Morris Property Address 74 NE 97 St Roofing Permit Number RF-01-19-97 Dear Building Official: I Carlos A Valderrama certify that the roof decking attachment and fasteners have been strengthened and corrected and a secondary water barrier has been provided as required by the "Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Structures" adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C. Qualifying Signature f Qualifying ent Carlos A Valderram Print Name L . I STATE OF FLORIDA CO OF MIAMI-DADS Sworn to and subscribed before me this 4th day of November , 2019 (SEAL) Wpd Do LA Pa cowoa+eoion #coo»r bon: 3 rA= Bonded tlw Arai Nohry X Personally known or Produced Identification