Loading...
RF-19-2925Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date:12/16/2019 Location Address Parcel Number 1060 NE 105TH ST, Miami Shores, FL 33138 1122320280070 :ontacts Permit No... RF-12-19-2925 Permit Type: Roof Work Classification: Flat Permit Status: Approved Expiration: 06/15/2020 Duplex 900 LLC Owner JUVAL CORPORATION Contractor 44 W FLAGLER ST 2300, MIAMI, FL 33130 ISMAEL RAMOS 2040 SW 123 CT, MIAMI, FL 33175 Business: 3054918438 Description: RE -ROOF BUR FLAT ROOF Valuation: $ 6,700.00 Requests: Inspection 305-4949 Total Sq Feet: 500.00 Fees Amount Application Fee - Other $50.00 CCF $4.20 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $1.40 Roofing Fee $200.00 Scanning Fee $12.00 Technology Fee $6.25 Total: $280.10 Payments Date Paid Amt Paid Total Fees $280.10 Credit Card 12/11/2019 $50.00 Check # 2334 12/16/2019 $230.10 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructioq W Ong. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date December 16, 2019 Page 2 of 2 RECEIVED r Miami Shores Village DE 11 2019 Building Department By: 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201"') BUILDING Master Permit No. ��"(2` �� 29 25 PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [_]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP 'w A►VrF, T CONTRACTOR DRAWINGS JOB ADDRESS: 1r OG1 1 Q 5 S1 Citv: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11' 2 * —02� °-0070 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: /I Flood Zone: BFE: FFE: OWNER: Names (Fee Simple Titleholder): U Pit)e qoo L b L Phone#: Address:_ $ 1 w Da8e( ST 2300, pM- o � mi I rz. 3S i 3o City: M/�i State: ! ta, a0\ Zip: 5 3(3 Tenant/Lessee Name: Phone#: Email: _JUv CONTRACTOR:_ Company Name: _corPc�1 �4, Phone#: 05— 111 —89' 9 Address: 5 5O 2 NW % sr - City: AN om State: RLVJQC,\ Zip: `3 3126 Qualifier Name: (S Ma(Q) 2wn u5 Phone#: 36 / l / 'b<36 State Certification or Registration^#: ccc J 330G Certificate of Competency #: DESIGNER: Architect/Engineer: ✓V k Phone#: Address: 7 City: State: Zip: Value of Work for this Permit: $ Gko oo Square/Linear Footage of Work: �0a� F Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑ Demolition Description of Work: re- roof B y 1`nn Ftod- roof Specify color of color thru tile: Submittal Fee $ 60 Permit Fee $ Scanning Fee $ Technology Fee $ Structural Reviews $ (Revised02/24/2014) Radon Fee $ Training/Education Fee $ CCF $ DBPR $ CO/CC $ Notary $ Double Fee $ Bond $ 'SOD TOTAL FEE NOW DUE $ 2,S0 , 10 -130-1 O . Bonding Company's Name (if applicable)NA V A Bonding Company's Address City State /� Zip Mortgage Lender's Name (if applicable) At - Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a c Ply of the notice of commencement and construction lien laybro re will be delivered to the person whose property is subjecttotachment. Also, a certified copy of the recorded notice of coment must be posted at the job site for the first inspection whi occurs seven (7) days after the building permit is issue Isence of such posted notice, the inspection will not, a d and a reinspection fee will be charged. Signatu OWNER or AGENT Signatu The foregoing instrument was acknowledged before me this The f 1 day of Ot)C?M\l-?/ 20 .rJ by i S rVLO RAM who is personally known o. CONTRACTOR instrument was acknowledged before me this t e � day of _ Q-ll 6,,' 20 _1 f( , by ic 7 me/ fz"a5 who -is personally known o me or who has produced as me or who has produced as identification and who rers ;i�YPY�¢, ANTHONYRODRIGUEZ dentification and who did t S�y:L �• ANTHONYRODRIGUEZ NOTARY PUBLIC: ,g ,: MY COMMISSION # GG 183488- MY COMMISSION # GG 183488 *: OTARY PUBLI ,: EXPIRES: February 6,2022 _ EXPIRES:February 6,2022 ;+, e ± ? ` Public Underwdters FBi i Bonded Thru Notary Public underwriters 'eoF . Bonded Thru Notary Sign: Print: R1 o-ques Print: O r, G Seal: Seal: C APPROVED BY t Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) apartment of State / Division of Corporations / Search Records / Detail By Document Number / Detail by Entity Name Florida Limited Liability Company DUPLEX 900 LLC ELRag Information Document Number L15000194734 FEI/EIN Number 47-5613872 Date Filed 11/17/2015 State F L Status ACTIVE Principal Address 44 WEST FLAGLER ST SUITE 2300 MIAMI, FL 33130 Changed: 03/23/2016 Mailing Address 44 WEST FLAGLER ST SUITE 2300 MIAMI. FL 33130 Changed: 03/23/2016 EMIstered Agent Name & Address EXCO US ATRIUM 44 WEST FLAGLER STREET SUITE 2300 MIAMI, FL 33130 Name Changed: 01/29/2018 Authorized Person)_jl Detail Name & Address Title MGR BEN SOUSSAN, LAURENT 44 WEST FLAGLER ST SUITE 2300 MIAMI, FL 33130 Title MGR SPORTICH, THIERRY 44 WEST FLAGLER ST SUITE 2300 MIAMI, FL 33130 Title Manager SCEMANA, PATRICE M 44 WEST FL AGLER ST SUITE 2300 MIAMI, FL 33130 Annual Repott3 Report Year Filed Date 2017 02/16/2017 2018 01/29/2018 2019 03/12/2019 Document Images 03/12/2019 — ANNUAL REPORT View image in PDF format 01/29/2018 — ANNUAL REPORT Mew Images a i� F format 02/16/2017 -- ANNUAL REPORT View image in PDF format 03/23/2016 -- ANNUAL REPORT View Image In PDF format 11/17/2015 -- Florida Limited Liability View image In PDF format GABLES ROOFING �� Juval corporation DBA Gables roofing 5582 NW 7th Street, Suite 200, CCC 1330038 State Certified Miami, FL 33126 (786)529-5663 PERMIT AUTHORIZATION FORM HOMEOWNER: L' itkt51- 900 , uuc To whom it may concern, I hereby authorization Juval Corporation DBA Gables Roofing to act as my agent for the purpose of securing a permit for the attached contract entered into by me. This authorization allows Juval corporations agents to sign the building application and other documents needed to obtain a construction permit and final inspection of said work as described in the contract as owner/ agent and if necessary to sign the owners name only for the purposes of such to the following described address. Address: 1060 NE 105 St, Miami, FL 33138 Printed Names: s: { VATRIt C le Si �� { t 4 s M an a p teq 4' 0-z) ll C_ Date Signed: 12/2/2019 *1� Signed and sworn before me this of lC 20 11 Produced ident' c 'on of: o 111 U -,/-I �d Gcn FL Notary signature: (Stamp) �► : M7 9 y' �YA NoWy ^& 111 OWNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT F, SIT BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami -Dade County Building Department H 805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name Property Address Roofing Permit Number bu0L17;v. 906, LLc 1060 NE 105 St Dear Building Official: I f ftyoGCer� SCApA- I A-1 M AV "01- 0 certify that I am of required to retrofit the roof to wall connections of my building because: M The just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. J P P The buildingwas constructed in compliance with the provisions of the Florida Building Code P (FBC) r with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC).� I Si Print Name Owner STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subscribed before me this day of T�2C.e�tzq 20 11 Miami Shores Village APPROVED BY DATE ZONING DEPT BLDG DEPT l l ;� n 4.If-r,T TO (,OMIT IANCE WITH ALL FEDERAL I I AM CON: I Y IMI FS AND RFOMLATIONS A (SEAL) R J 11 2019 Pe onally known ti �'�8.� By or Produced Identification y' n ,,, kAftbuAmm Nobly When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC, and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided. C:VJocumcnts anJ ticuingsYicl Wfy DocumcntstimUstics(irnphs 2VZoofing AffidaviCompliance-92607FiIlahle.Jvv MIAMI-DADE COUNTY REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to ex- plain to the owner the content of this form. The owner's initials in the designated space indicates that the item has been explained. 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velociq.Murricade Zlarfi') are.. •„• for the purpose of providing that the roofing system meets the wind resistance and jaiter intrusion perfor-. • mance standards. Aesthetics (appearance) are not a consideration with respect toy"*r;anshirprovisions.: " Aesthetic issues such as color or architectural appearance, that are not part of a tantng code, should be..... addressed as part of the agreement between the owner and the contractor. . • • • • • ' .. .. . ...:.. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck rrh% i% lh to be rebailed in • accordance with the current provisions of Chapter 16 (High Velocity Hurricane tones) oT the Florda SuildinEr .. • 0 • Code. (The roof deck is usually concealed prior to removing the existing roof system). • • ..• . . .. . ... . . . . . 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be < viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause wa- ter to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. 8. Existing Solar Systems: The stallation of an existing roof mounted photovoltaic system requires a arate permit. Permit m ined i"Wirdyft ize g permit. RWM * n of GG 19Eii2 : aU CONr.�SHU"RM 1060 NE 105 rAMUZ ED 1ZL01,W 3+e Miami rutmffNuA= FL 33138 :in n. Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section A („Genera! information) Master Permit No. Process No. Contractor's Name _ Juval Corporation ;. Job Address 1060 NE 105 ST • • • • • • • • ROOF CATEGORY • • • • .... . ..... ■ Low Slope ❑ Mechanically Fastened Tile ❑ Mortfif1Xd6eslv4 AQCTlle • • • • ...... ❑ Asphaltic ❑ Metal Panel/Shingles❑ Woot.COb.iggleAhVkes Shingles • • Are there:...:. ❑ Prescriptive BUR-RAS 150 Gas Vent Stacks? Yes Noe.i .". • ROOFTYPE Type: Natural) 006)(D ❑ New Roof ■Re -Roofing ❑ Recovering ❑ Repair ❑ Maintenance . ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 500 I 500 Section B (Roof Piano Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. ■r■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■�■■■■■■■■■■■■■■■■■■■■■■■ti ■ ■�■ rpr go mail E a r rA sip .BEd ■. 11 IL All EC C ■.. ■ 50 C . r ■I■■ E.ii■.■■ee.r.C�j, �rj■ i::01 . a y ■4 r- W110■, ■E. ■ rFso G .. ■ G rC EE. ��� a■C. C CC gig rG�r�r, ■ ��� G ■lr�� y . ■fir a r■ r■ r ■ � ■ ■��#� Q ■ ■ C■ r r I�C ri: , ■ ■ C iris .� di ■ r � ;,, � I ■ ■ ■ �! r 1 1 ..dE� ■ � riiC ■ C. r C �� ■ ■ C C ■ i�w�.�■�s■�rii Florida Building Code 6th Edition (2C17) High -Velocity Hurricane Zone Uniform Permit Application Form Section C(Low Slo ed Roof System) Fill in Specific Roof Assembly Components and ldenft Manufacturer (if a component is not used, kWn�* as •NA j System Manufacturer 6A i" NOA No.; Qa Design Wind Pressures, From RAS 128 or Calculations: Pmaxt:ePze Pmax2: / 1,7 Pmax3:-6_ Max. Design Pressure, the Specific NOA System:- _----t } Deck: ! ri Type:1 X Gaicmess: / Slope: + ; , 2 Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer, Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) a No. of Ply(s): %b LPd6e Ilut —1 B�Sheet Fastener"n� t Material: Ply Sheet(s) & No. of Ply(s): Y�Tr_ TOP Ply. M c�^t'rW 5 i1 r��G{ rot PSl2Ci T Ply Fastener/ I aterial: Surfacing:_ i`r` C U rf V�C kO C,& PS t Fastener Spacing for Anchor/Base Sheet Attachment Field: G ' oc @ LOP. # Rows 2_ Perimeter. oc ®Lap, # Rows` oc Comer f• oc @ Lap, # Rows �f: oc ' • Number of Fasteners Per InsNiation Board •••••• Field Perimeter cOm9t �• Illustrate Components Noted and Details as Applicable: • • • • • Woodblocking, Gutter, Edge •TerrhinatioQ •• Stripping, Flashing, Continuous Cleat, Can! o • • Strip, Base Flashing, Counter- Flashing, Coping, Etc, Indicate. Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that ComPIY with RAS 111 and Chapter 16. rT" I /T-awhLJ r �'tt MPM6rov,eSlti'P FT. 3 x 3 Dr; Parapet Height Ply 4 Z P1�'eS -7 5 8- Pk,;eShe p} FT. t(j' 6- M ean nRoot Height • *Soso* • s MIAMI-D %DF COI NTV PRODUCT CONTROI. SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OE RIsGULATORV AND ECONOMIC RESOURCES (IIER) Miami, Floricla 33175-2474 BOARD AND CODE ADNIINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.etlyLc Uftly s .. GAF .. 0 1 Campus Drive ••.. e •••• a .. Parsippany, NJ 07054 sees** • SCOPE: . NIS This NOA is being issued under the applicable rules and regulations governing tile o const+e use vctiotjeee;s materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowell by'tlte Authority Having Jurisdiction (AHJ). s �••009 so.* • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Products•O**• Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein. and has been designed to comply with the Florida Building Code including the Flit;h Velocity I lurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city. State and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been tiled and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County. Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1030.01 and consists of pages I through 27. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page I of 27 Osseo* s OOe o• o Oeoo• 90000 o .... . O ROOFING SYSTEM APPROVAL Catcuory: Rooting Sub -Category: BUR Material: Fiberglass Deck Tyne: Wood • Maximum Design Pressure: -97.5 psf. ••. • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED Bl' API'l;�fjv�T: �• TABLE 1 •••• Test ProdU4:::. • Product Dimensions Specification DescrintiASt.' ;••••• GAFGLAS Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic jI' �ho0et reinforced Wide with fiberglass mat. 00049 Tri-Ply"Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic p?�sheet reiipolcctL Wide with fiberglass mat. "" GAFGLAS"' 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced FlexPly"' 6 Wide with fiberglass mat. GAFGLAS475 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Base Sheet Wide with fiberglass mat. Tri-Ply'"- 475 Base 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Sheet Wide with fiberglass mat. GAFGLAS #80 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Ultima"' Base Sheet Wide with fiberglass mat. GAFGLAS' 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic perforated venting base Stratavent-' Wide sheet reinforced with fiberglass mat. Perforated Venting Base Sheet GAFGLAS"' 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic nailable venting base StratavenO'Nailable Wide sheet reinforced with fiberglass mat. Bottom side Venting Base Sheet surfaced with granules. Ruberoid" 20 39.37 (1 meter) ASTM D6163 SBS polvmer-modified asphalt base or Smooth Wide anchor sheet reinforced with a fiberglass neat. Ruberoid`' Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid' Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or anchor Smooth 1.5 wide sheet reinforced with a polyester mat. Ruberoid`' Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or Plus Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid'N HW 25 39.37" ( I meter) ASTM D6163 Smooth surf,iccd torch applied SBS base or anchor Smooth wide sheet reinforced with a libei-lass mat. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date. 11/08/18 Page 2 of 27 TRADE NAiMFS OF PRODUCTS MANUFACTURED OR LABELFD BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Descrintion Ruberoid" HW 39.37" (1 meter) ASTM D6164 Smooth surfaced torch applied SBS basebr,j;for Smooth wide sheet reinforced with a poly;ste r naat. • GAFGLAS`"' 39.37" (1 meter) ASTM D3909 •• • Granule surfaced asphaltic c'0':'j"t reirrioieed• Mineral Surfaced Wide with fiberglass mat. •"•••• • Cap Sheet .'••Ya ;•••;• Tri-Ply' BUR 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic e-11 hjet reiitforcod Granule Cap Sheet Wide .. .. •••• with fiberglass mat. :• GAFGLAS') 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic Zapshiet reinforced EnergyCap`" Wide with fiberglass mat. Cap sl:eetia futorrcoate'd Mineral Surfaced with TOPCOAT" FnergyCotc•'" 4,1,4oleric•• Cap Sheet Coating. •••• Topcoat"-' Surface 5 or 55 gallons ASTM D6083 Solvent -based thermoplastic rubber Seal SB sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. Topcoat' 1, 5 or 55 gallons ASTM D6083 Water -based elastomeric coating Membrane Topcoat`' MB Plus 5 or 55 gallons Proprietary Water based. low VOC primer designed to block asphalt bleed -through. Topcoat' FireOut' 5 or 55 gallons Fire Barrier Coating VersaShield" Fire- 12" x 100' rolls Resistant Roof Deck Protection VersaShieldW' Solo"' 42" roll wide, 100 Fire -Resistant Slip ft. Sheet Proprietary Low VOC, water based fire barrier coating. ASTM D226 Non -asphaltic, fiberglass reinforced underlayment and!or fire barrier ASTM D 146, D828, D4869, D6757 Topcoat' 1, 5 gallons or TAS 139 FlexSealT"' 1 qt. tube Non -asphaltic, fire resistant fiberglass underlayment Solvent -based elastomeric sealant. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 3 of 27 APPROVED INSULATIONS: TABLE 2 Product Name Product Description EnergyGuard"' Polyiso Polyisocyanurate foam insulation Insulation EnergyGuard`" Tapered Polyisocyanurate foam insulation Polyiso Insulation EnergyGuard"' Ultra Polyiso Glass -faced polyisocyanurate foam insulation Insulation EnergyGuard"' RA Polyiso Polyisocyanurate login insulation InSUlatlon EnergyGUard"' RA Composite Polyisocyanurate foam insulation with high POlyiso Insulation density fiberboard or permalite EnergyGuard"' RH Polyiso Polyisocyanurate foam insulation Insulation EnergyGuardT"' RH Tapered Polyisocyanurate foam insulation Polyiso Insulation EnergyGuard"' RN Polyiso Polyisocyanurate foam insulation Insulation EnergyGuard"' Perlite Roof Perlite insulation board Insulation EnergyGuard" Perlite Recover Perlite recover board Board SeCllrock"' Gypsum -Fiber Roof Gypsum board Board Securock' Glass -Mat Roof Glass faced gypsum board Board Structodek`' High Density Fiber High density fiberboard Board Roof Insulation DensDeck'" Prime Roof Board Gypsum board DensDeck't Rool' Board Gypsum board Manufacturer With Current NOA sees.. ...4iAF . .see . • • sees• sees.. . .e..j(�AF • sees sees.. . • (GAF • (ZAF sees GAF GAF GAF GAF GAF United States GN psunl Corp. United States Gypsum Corp. Blue Ridge Fiberboard, Inc. Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum LLC NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 4 of 27 sees.. . Goose• sees.. ..... . . sees. •.•..• . . .woes• . APPROVED FASTENERS: TABLE 3 Fastener Product Product Number Name Description 1. Drill-Tec'" 412 Fastener Phillips head, modified buttress thread, pinch point. carbon steel fastener for use in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. 2. Drill-Tec"' 414 Fastener Truss head, self -drilling. pinch point. high thread fastener for use in steel, wood or concrete decks. 3. Drill-TecT"' ASAP 3S Drill-TecT" #12 Fastener with Drill-TecT"' 3" Standard Steel Plate. 4. Drill-Tec"' 3" Steel Plate Round GalvalumeR steel stress plate with reinforcing ribs and recessed for use with Drill-Tec" fasteners. 5. Drill -"I ec" 3" Standard Steel Galvalume`" coated steel Plate stress plate for use with approved Drill-Tec" fasteners. 6. Drill-Tec" ACCUTra& Flat A2-SS aluminized steel plate Plate for use with Drill-Tec" fasteners. 7. Drill-Tec" AccuTracCR' Galvalume(g'steel plate with Recessed Plate recess for use with Drill- Tec"' fasteners. 8. Drill-Tec 3 in. Ribbed Round Gal�alume"Ji' plated Galvalume Plate (Flat) steel stress plate v, ith reinforcing ribs for usr with Drill--ec" fasteners. Manufacturer Dimensions (With Current WA) 912 x 8" max. ; G ,•• length. #3 •' • :•. •• Phillips head. • 414 x 16" �••:�: GAF • max. length, •.•••, #3 Phillips •••• i • head. • •• • • • See GAF components 3" Round GAF 3" Round GAF 3" square; GAF 0I T' thick 3" square; GAF .017" thick 3" R011nd GAF NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 5 of 27 EVIDENCE SUBMITTED: Test Auencv Factory Mutual Research Corp. UL LLC PRI Construction Materials Technologies, LLC Test Identifier Description 3014547 4470 3029832 4470 3033135 4470 3034312 4470 3036980 4470 3038278 4470 3040738 4470 3041769 4470 3042887 4470 3042905 4470 3046081 4470 3046388 4470 3047636 4470 ODOA8.AM 4470 OD I A8.AM 4470 OY9Q5.AM 4470 1 B9A8.AM 4470 2138A4.AM 4470 3 B9Q I .AM 4470 3 D4Q2.A M 4470 797-03221-267 4470 797-03825-267 4470 797-10228-267 4470 R1306 UL 790 GAF-122-02-01 TAS 139 GAF-270-02-02 ASTM D226 GAF-276-02-01 Rev ASTM D6083 GAF-276-02-02 ASTM D226 GAF-306-02-01 ASTM F.96 GAF-314-02-01 ASTM D2178 GAF-315-02-01 ASTM D2178 GAF-369-02-01 ASTM C1289 GAF-417-02-01 ASTM C 1289 GAF-464-02-01 ASTM C1289 GAF-464-02-01 ASTM C1289 GAF-499-02-01 ASTM )6083 GAF-500-02-01 ASTM D6083 GAF-549-02-01 TAS 114 GAF-549-02-02 TAS 114 GAF-559-02-01 TAS 117(13) GAF-559-02-04 ASTM D 1876 GAF-559-02-05 ASTM D 1876 GAF-559-02-06 TAS 1 14(H) GAF-559-02-07 ASTM D 903 GAF-559-02-08 ASTM D 903 .. •00:•• •00000 Date 05/22/03 05/ 1 1 /07 1 1 /24/08 04/09/09 08%14/09 11/18,11 11/16/10 05/26/ 1 1 1 1/14/1 1 01/10/12 02/13/13 09/24/ 12 08/08/ 13 07/Q9/99 ; "7�19/94 ,04/Q 1 /98 040/97 07*02/97 %0.145/98 05/30/97 :.(":7/07 07/21/08 01/;3/15 ...... 08/21/18 OW/06 11/15/10 12/16/10 11115110 07/07/ 1 1 08/23 / 1 1 08/23/ 1 1 10/22/ 12 05/28/ 13 10/22/12 02/06/ 14 03/ 12/14 03/12/14 08/08/ 14 08/08/ 14 09/30/ 14 10/01/14 10/15/14 10/02/ 14 10/02/ 14 10/02/ 14 NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Pate 6 of 27 EVIDENCE SUBMITTED: (CONTINUED) Test Ap_ency Test Identifier Description Date PRI Construction. Materials GAI -559-02-09 ASI'M D 903 10,02/14 Technologies. LLC GAI--5i9-021-I I TAS 114 10/14/14 GA1--559-02-12 TAS 114 1014/14 GAF-559-02-13 TAS 114 10/15/14 GAF-559-02-14 TAS 114 10/15/14 GAF-559-02-15 TAS 114 10/15/14 GAF-559-02-16 TAS 114 10/15/14 GAF-559-02-18 TAS 114 10/15/14 GAF-559-02-19 TAS 114 04/16/15 GAF-628-02-01 ASTM C 1289 05/31 /16 IRT of S. FI. 02-005 TAS 114 01/18/02 02-014 TAS 114 03/22/02 Trinity I ERD C8500SC. 11.07 TAS 117 91 1/3Q/07 G30250.02.10-3-R2 ASTM D3909 WWIM 5 G31360.03.10 ASTM D616I..� : vG0/34/10 G311470.0,.1 1 AS F%I D6164s*:•• :I 1%*71 1 G34140.04.1 1-2 ASTM DO1601""' 04 15/1 1 G34140.04.1 1-4-R2 ASTM D040;"". :V6A3 15 G34140.04.1 1-5-R3 ASTM D4897" * * e "06!04/ 15 G36780.07.1 I -R 1 4470-TAS 114 : * *: 4*4,4I 1 G40630.01.14-1 ASTM D616:: .::. 01 /Q6/ 14 G40630.01.14-2A ASTM D616$ .01/0' /14 G40630.01.14-2A-1-RI ASTM D6166 WIWI4 G43610.01.14 ASTM D390N - * •0 I /i3/ 14 G6850.08.07-1 ASTM D3909 O-W+t /07 SC6870.08.14-R 1 ASTM D3909 09/04/ 14 SC9700.08.15-R 1 ASTM D2178 8/31 /2015 SC 10680.05.16 ASTM D6163 5/ 10/2016 SC 13105.03.17-R I ASTM D6164 3/23/2017 Dynatech Engineering Corporation H4482.02 95-1 TAS 114 09/01/95 Atlantic 8 Caribbean Roof 1 1-053 TAS 114 08, 12/1 1 COnSUltants. LLC NOA No.: 18-0919.07 Expiration Dater: 11/04/23 Approval Date: 11/08/18 Page 7 of 27 Membrane Type: BUR Deck Type 11: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type F(3): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOutT" Fire Barrier Coating, VersaShield" Fire -Resistant Slip Sheet or (optional) VersaShield`') Solo"' Fire -Resistant Slip Sheet installed per nlanutacturer'S installation instructions. Anchor sheet: GAFGLAS'� #75 Base Sheet, Tri-Ply" #,75 Base Sheet, Ruber0i(14 20 SI1100th Or GAFGLAS`" Strataven�r Venting Nailable Base Sheet is Secured as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —45 psf See General Limitatimp#7)� • • • • • • • Fastening Miami -Dade County Approved min. 12 ga. annular ring shank pWjjjipd milt 1=j/i4'in. ••��;� Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide ancjlpji:hoot side laps and 6 . .... in. o.c in the field of the sheet in two staggered rows. .... (Maximum D _P=rvssure.---5 ,5 �s ' S'ee General Limilatiun#7# ••••. FasteningDrill-Tec"' 414 Fasteners and Drill-Tec`°' 3 in. Standard Steel P �� •Drill-73 ��•• •�••• .I� l . Option #3: ...... ACcuTrac' Flat Plates or Drill-Tec"' 3 in. Ribbed Galvalume 1?14tc. Flat) are spaced 16 .' in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. t.c. in the field of the shecv*..:. in two staggered rows. (Maximum Design Pressure: —52.5 p.sf See General LinikatiomV 7)0 .00. • Fastening Drill-Tec'°' 414 Fasteners and Drill-Tec'"' 3 in. Standard Steel Plates. Drill-Tcc' Option #4: ACcuTraclFlat Plates or Drill-Tec`°' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-Tec"' #14 Fasteners and Drill -Tee"' 3 in. Standard Steel Plates, Drill-Tec`°' Option 45: ACCUTrac' Flat Plates or Drill-Tec'°' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the nlin. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —97.5 psf See General Limitation #7) Ply Sheet: When optional cap sheet is present: Two or more plies of GAFGLAS- Ply 4, Tri-Plv* Ply 4, GAFGLAS`"' Flex Ply 6 adhered in a u I mopping of hot aspha t applied at 20-40 lbs./sq. installed per manufacturer's Installation II1StrLICti0I1S. When optional cap sheet is not present: Three or more plies of GAFGLAS'R' Ply 4, Tri-Ply° Ply 4, GAFGLAS" Flex Ply 6 adhered in a full plopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. NOA No.: 18-0919.07 Expiration Date: I1/04/23 ;approval Date: 11/08/18 Page 23 of 27 Cap Sheet: Surfacing: (Optional) GAFGLAS" Mine rfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS Energy ap ' Mineral Surfaced ap heet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. I . Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at I to 1.5 gal./sq. OR Topcoat" MB Plus applied at 0.5 to 0.75 gal./sq.(to be use(l as a primer) followed by Topcoat Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Rool'Coating. Maximum Design Pressure: See Fastening Above. • Y ...... . .. ...... •••••• • • ••••• • • • • • •••••• •• • • •• • • • • NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date. 11/08/18 Page 24 or27 WOOD DECK SYSTEM LIMITATIONS: I A slip sheet is required with GAFGLAS ` Ply 4 and GAFGLASe Flex Ply"' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/4 DensDeck`" Roof Board or ! "" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping oi'approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied usirjg spat mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbckns in three r(V1,'0'1Te at ....•. each sidelap and one down the center of the sheet allowing a continuous area of ventilation• 1:11circli*2 olithe •• strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow crclsmalnlilatioit 'A*tphalt ••••�• application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attaelf&f tf stems shall be ;••��� limited to a maximum design pressure of -45 psf. """ " " " 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (t� value of�75 Ibf., as tested in compliance with Testing Application Standard TAS 105. If the fastener valueiaqt*;d-test*d,•w*e4below...��� 275 Ibf. insulation attachment shall not be acceptable. ••�"•• �• 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachm:nt M. Eased qp a nlinimuin" fastener resistance value in conjunction with the maximum design value listed within a.&peci#ic systIn'S'liould the " fastener resistance be less than that required, as determined by the Building Official, a rewisckaster rspacing. :�•��: prepared, signed and sealed by a Florida Registered Professional Engineer, Rcgistcred Architect. or RfalStered Roof Consultant may be submitted. Said rc\ iscd fastener spacing shall utilize the withdrowal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Rooting Application Standard RAS 1 17. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Rooting Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 3. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Rooting Application Standard RAS I I I and applicable wind load requirements. �. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation 47 will not be applicable.) 10. All products listed herein shall have a quality assUrance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Cole. END OF THIS ACCEPTANCE NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 27 of 27