RF-19-2922Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address �rZ"`�Irnn)l� Issue Date:12/19/2019 Parcel Number 551 NE 105TH ST, Miami Shores, FL 33138 1122310140280 Contacts Permit NO.: RF-12-19-2922 Permit Type: Roof Work Classification: Flat Permit Status: Approved Expiration: 06/ 16/2020 BENIGNO MENDEZ Owner IBIS ROOFING INC Contractor 551 NE 105 ST, MIAMI SHORES, FL 331382044 JULIO MARROQUIN 2961 NE 2 DR, HOMESTEAD, FL 33033 Business: 3058158455 julio@ibisroofing.com Description: ROOF REPLACEMENT FLAT Valuation: $ 2,800.Inspection Requests: 00 1305-762-4949 Total Sq Feet: 250.00 Fees Amount Application Fee - Other $50.00 CCF $1.80 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $0.60 Roofing Fee $200.00 Scanning Fee $9.00 Technology Fee $6.25 Total: $273.90 Payments Date Paid Amt Paid Total Fees $273.90 Credit Card 12/11/2019 $50.00 Credit Card 12/19/2019 $223.90 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authoFizq the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / / Agent Date December 19, 2019 Page 2 of 2 BUILDING PERMIT APPLICATION Miami Shores Village C EIVED Building Department OEc 1 019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 BY: INSPECTION LINE PHONE NUMBER: (305) 762-4%9 FBC 20 } Master Permit ❑BUILDING ❑ ELECTRIC Q ROOFING ❑PLUMBING JOB ADDRESS: 55 Sub Permit No. ❑ REVISION ❑ EXTENSION [:]RENEWAL 1 ❑ MECHANICAL [:]PUBLIC WORKS ❑ CHANGE OF Nis CONTRACTOR NW 105th Street ❑ CANCELLATION ❑ SHOP DRAWINGS City: Miami Shores County: Miami Dade Zia: Folio/Parcel#:11-2231-014-0280 Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Benigno Mendel Phone#.N 7 o S' S ) 5- a 7 S Address:551 NE 105th Street City. Miami Shores State: FI. Zip: 33138 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Ibis Roofing Phone#: 305.815.8455 Address: 2961 NE 2nd Dr City: Homestead state: FI Zip: 33033 Qualifier Name: Julio Marroquin Phone#: 305.815.8455 State Certification or Registration #: CCC1326214 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Value of Work for this Permit: $ x �) . L? OD lab� Square/Linear Footage of Work: 250 Type of Work: ❑ Addition ❑ Alteration ❑ New Description of Work: Roof replacement - flat M Repair/Replace Zip: ❑ Demolition Specify color of color ru tile: Submittal Fee Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Notary $ Double Fee $ Structural Reviews $ (Revised02/24/2014) Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address Zi p City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved qQd a reinspection fee will be charged. Signatu or AGENT The foregoing instrument wasl acknowledged before me this 1 b day of liec_e 6- r , 20 by cam, r1 d-,z , who is personal) _ nown to me or who has produced as identification and who did take an�pli4 MARROQG,,��� �o� 09Lp NOTARY PUBLIC: , •,• ;_ ��0 _` * ; Rs- 0 �O #GG295212 V- •• Si4:2Z a sue" O� �i o•:;8hisiS�a••• Print:4 Seal: Wmlllllll0\\ Signatu CO RACTOR The foregoing inst70( nt was acknowledged beforemethis Q" day of 20 / by il'U tX /-4ho is ersonally know to me or who has produced as identification and NOTARY PU JULISSA E ARAUZ Notary Public - State of Flerija .1 z Commission # GG 112973 �'F My Comm. Expires Jun 2, 2021 :. .... ' Bonded through National Notary Assn. Print: Seal: to ssssssssssssssssssssssssssssssssss ss sssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssss APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) OFFICE OF THE PROPERTY APPRAISER O0b 1. Summary Report Property kdomnation Foio: 11-2231-014-0280 Property Address: 551 NE 105 ST Miarr Shores. FL 33138-2044 Owner BENIGNO S MENDEZ Yaiing Address 551 HE 106 ST MIAMI SHORES, FL 33138-2044 PA Prirna►y Zone 1000 SGL FAMILY - 2101-2300 SO Pay Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNrr Beds / Badrs / Half 3/2/0 Floors 1 Living Units 1 Actual Area 2.133 Sq.Ft Living Area 1,777 Sq.FI Adprsfed Aran 1,942 Sq.Ft Lot Stm 9.150 Sq.FI Year Built 190 Assessment krformation Year 2019 2018 2017 ue $194.424 $185.165 $205.739 Buldsg Value $129" $121,647 $121,647 XF Value $12,119 $12.121 $12,123 lltaket Value --- $328 190 $318.933 $339,509 Assessed Value $243,297 $238,761 $233,851 Benefits kdormation Benefit Type 2019 2018 2017 Save Our Homes Cap Assessment Reduction f 84.893 $80,172 $105,658 Homestead Exemption $25,000 $25,000 $25.000 Second Homestead Exemption $25.000 $25,000 $25,000 School Note- Not all benei0.s are applicable b all Taxable Values (Ai.e. Board. City. Regional) - Short Legal Description AMD PL. MIAMI SHORES SEC 5 PB 10-47 LOT 19 & W1/2 LOT 20 BLK 110 LOT SIZE 75.000 X 122 OR 20663-1614 09 2002 4 Generated On: 121312019 Taxable Value krformation 21191 2018 2017 County --- — Exemption Value W'0001 $50.000 SW.000 Taxable Value 1 $193.297 $188,7611 $183,851 School Board Exemption Value $25,0 0 $25,000 $25.000 Taxable Value 1 $218,297 $213.7611 $208,851 City Exemption Value $50.000 $50,000 $50,000 Taxable Value $193.297 $188,7611 $183,851 Regional Exemption VaAre $50,000 $50.0mi $SOOM Taxable Vane I $IM_>971 $188,7611 $1a3,851 Sales Infomtadon Previous OR Book- Price Quaification Description Sale Page 19252- Sales which are disqualified as a recut of 07A12000 $0 0412 examination of the deed 12000 $0 19044- Sales which are disqualified as a result of 0962 examination of the deed 18917- Sales which are disqualified as a result of 12/01/1999 S0 0%7 examination of the deed 18882- Sales which are disqualified as a result of 11/01/1999 S0 4448 examination of the deed The Office of the Property Appraiser is continually editing and updating the tax rd. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at httpJ/www.miamidade.govfiinfoldisdaimer.asp Version: Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: Benigno Mendez Property Address: 551 NE 105th Street Miami Shores, FI.33138 Roofing Permit Number: Dear Building Official: Date: 12/4/2019 I Benigno Mendez certify that I am not required to retrofit the roof to wall connections of my building because: Q The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition ofAt e South Florida Building Code (1994 SFBC) Signature State of Florida County of Dade Benigno Mendez Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this ` �'` day of .A-Lx-,r Z L-A c, Notary Public, Sate of Florida at Larg4----)>a�� IV When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the budding was not constructed with FBC nor a 1994 SFBC. Then you must provide a budding application from a General Contractor for the Roof to Wall conneclion Hurricane Mitigation. Revised on 5/21/2009 :�g Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) ter VPermit Number Process Number sm"t, A r"l PPD Contractor's Name Ibis Roofing, Inc. Job Address 551 NE 105th Street ROOF CATEGORY Low Slope Mechanically Fastened Tile E] Mortar/Adhesive Set rile Asphalt Shingles E] Metal Panels/Shingles E] Wood Shingles/Shakes 0 0 : 00000 Is there an existing Roof Top Solar System? Yes Q No Will it be reinstalle47 1r: Yes C' No Are there gas vents on the roof? Yes Ot No Type? E] NatugaL:F±3 LPGX • ROOF TYPE New Roof Repair E] Maintenance 0 Reroofing E].11he0ering; ROOF SYSTEM ROOF INFORMATION • Low Slope Roof Area Re) 250 Steep Slope Roof Area (fe) rvAal (IF) 254 o 0000 Section B (Roof Plan) tchjdi,e Roof Plan: Illustrate all levels and sections, roof drain, sc erflow4gopers and overflow drains. ud di � dimension Elvlal' ens sections and levels, clearly identify dim4 onj of eleva :06i;4iiA-es-andjqcations of parapets. � --t APPpr, ............... ............ 25 10 P T 0G',yt1,,—!E wl IFH Al I F L Fc/, f riLA W-AT",l is V W11G1 5 PIUMIUMIVII rUl III n V nG 6V 1 V "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES- REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Z ne) are for the purpose of providing that the roofing system meets the wind resistance and vyatel intrusion erformance standards. Aesthetics (appearance) are not a consideration with res eat to-workriga li rv% isiens. P (PP ) P . P P Aesthetic issues such as color or architectural appearance, that are not part of a zoniri cdde, s�iourd be air=ed ..... as part of the agreement between the owner and the contractor. ...:.. • 2. Renailing wood decks: When replacing roofing, the existing wood roof A may have to be• ; • • . renailed in accordance with the current provisions of Chapter 16 (High Velocity Hu3-Wfie Zoi�f the.tlI jWa Building Code. (The roof deck is usually concealed prior to removing the existing wQi4stem).. •; 3. Common roofs: Common roofs are those which have no visible delineatiop between neighbMiug: units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofmg contf4.Ct*gr and%r owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6.Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of. Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida -licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's/Agent's Signature: Contractor's Signature: Property Address: L57 l e l 0 S-'tA 5)r..e. Date: Permit Number: SECTION 1525 HIGH VELOCITY HURRICANE ZONES —UNIFORM PERMIT APPLICATION Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List hipw • Low Slope Application A B,C 1,2,3,4,5,6,4t • • • Prescriptive BUR-RAS 150 A,B,C 4,5,61% Asphaltic Shingles A,B,D 1,2,4,5N-A•• • Concrete or Clay Tile A B,D,E 1,2,3,4,�e;,J• •: • • Metal Roofs A,B,D 1,2,3,4,5467••• Wood Shingles and Shakes A,B,D 1,2,4,5,$,7 Other As Applicable 1,2,3,4,A,7• : • ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4_ Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as 'NA*) System Manufacturer_ GAF Materials Product Approval No.: 15-0729.18 Design Wind Pressures, From RAS 128 or Calculations: P1: -42.8 P2: -71.7 P3:-108.0 Max_ Design Pressure, from the specific product approval system: -59 Deck Type: Wood Gaugefrhickness: Min.5/8" Slope:Q Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer. Top Ply Fastener/Bonding Material: Rhinnband rnlatPs with U14 Fastenpm Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment Field: ' oc @ Lap, # Rows @ • oc 24x36" Grid Perimeter: " oc @ Lap, # Rows _ @ T' oc 24x24 grid 18xia4 <3rid Corner: " oc @ Lap, # Rove .'.� ' ' oc Number of Fasteners Per InsulAbllydard: Field Perimeter • • • • • COgw:. ' .... . ..... Illustrate Components Noted andOetaits as A;)pVgfte: Woodblocking, Gutter, Edge Terftrl Lion, Stripping, FlashiAfi,e * Continuous Cleat, Cant Strip, Baae•Fleshing, Counterflashing, • Coping, Etc. 000000 Indicate: Mean Roof Height, Parapet•Height,•Height of Bft...; Flashing, Component Material, Wtenal ThicllIngW, fasterter Type, Fastener Spacing or Submit ManufacturemeBetails that Comply with RAS 111 and Chapter 16. m Base Insulation Size and Thickness: 8" Flashing strip in Base Insulation Fastener/Bonding Material: Top Insulation Layer Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet FastenerBonding Material: Ply Sheet(s) & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply. GAF Everguard TPO 60 mil Z_ wood 3x3 26 ga tpo coated metal Para 10 Mean Roof Height Florida Building Code 6th Edition (2017 ) High Velocity Hurricane Zone Uniform Permit Application Form Section D (S Sloped Roof System) Roof System Man cturer. Notice of Acceptance umber. Minimum Design Wind sures, If Applicable (From RAS 127 or Calculations): P1: P1: Roof Slope: : 12 Ridge Ventilation? Mean Roof Height: Type: Underlayment Ins lion: F Fi Barrier: F ene .•. .. . ... [00. ...... . . ...... ..• .... . . . f0: .... . ..... ...... .. .. . ... ... ...... . 00 . . . . ...... . . ...... .. . . .. . • Type & S cog: 0000 esive pe: e Cap Sheet Covering :fie & Size Drip Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Pennit Application Form Section E Tile Calculations) For Moment sect file systems\Resistan choose either Method 1 or 2. Compare the values for M, with the values fr are greater thM, values, for each area of the roof, then the tile attachment method is a Method 1 'Moment Based Tile Calculations Per RAS 127' x _ _ J — Mg: = M„ Product Approval M, _ ) — Mg: = M� Product Approval M, _ ) — Mg: = Mr, Product Approval M,Method 2 'Simplified Tile Calculations Per Table Below"Required Mom(M,) From Table Below Product Approval M, • M,. If the M, values • • •••••• M, required Moment Resistance' Mean Roof Height Roof Slope 15' 20' 25' 30' s • • 40' • 2:12 34.4 36.5 38.2 39.7 1--:39.8 ..' 422 :' 3:12 .2 34.4 36.0 37.4 � • • 4:12 30. 32.2 33.8 35.1 " s 037.3 5:12 28.4 30.1 31.6 32.8 • :34.9 • 6:12 26.4 28.0 29 30.5 . 9 32.4 • 7:12 24.4 X 25.9 .1 28.2 • 030.0 . 'Must be used in conjunction with a list of moment ased tile si Appeals. For Uplift based the systems use Method 3. Compared values equal to the Fr values, for each area of the roof, then the ti attacl Method 3 'Uplift Based (P1: xL = xw:= )—W: xCos 6 (P2 xL = xW..= )—W: xCos 6 — (P3: x L = x W. _ ) — W: x cos = •••••• • • • • • endorsed by the Broward County Board of Rules and with the values for Fr. If the F' values are greater than or method is acceptable. alculations Per RAS 127" F„ Product Approval F' Product Approval F' k--- Product Approval F' WheA to Obtain Info ation Description ymbol Where to find Design Pressure 1 or P2 or P3 S 127 Table 1 or by an engineering analysis gre- ed by PE based on ASCE 7 Mean Roof Height H Jo ite Roof Slope 6 Job Aerodynamic Multiplier ). Produ pproval Restoring Moment due to Gravity M9 Product A roval Attachment Resistance OFM, Product AppXval Required Moment Resistance M9 Calculated Minimum Attachment Resistance/F' Product Approv Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be s mitted to the building official at the time of permit application. MIAMI-DADE MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Strcet, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADNIINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade. ,nv/ccmiomv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: ...... • • This NOA is being issued under the applicable rules and regulations governing the useef;aAstruction' materials. 'rhe documentation submitted has been reviewed and accepted b Miami -Dade oun RER.: • Product Control Section to be used in Miami Dade County and otherareaswhere allow ed Uy, he Authority Having Jurisdiction (AHJ). • • :66049 •• •• This NOA shall not be valid after the expiration date stated below. The Miami -Dade CbGH Drodu q Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. tf ljtis Droduct oi: • material fails to perform in the accepted manner, the manufacturer will incur the expense of such testii� - and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF EvcrGuardo TPO Single Ply Rooting Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 15-0203.20 and consists of pages I through 27. The submitted documentation was reviewed by Jorge L. Acebo. 1�j NOA No.: 15-0729.18 MIAMI•DADECOUNTY Expirations Date: 09/22/20 Approval Date: 09/10/15 Page 1 of 27 Membrane Type: Single Ply, TPO Deck Type 1: Wood, Non -Insulated Deck Description: Min. 15/32" thick plywood attached to structural wood supports spaced maximum 24" o.c. using 8d ring shank nails spaced 6" ox. at panel end supports and 12" o.c. along panel intermediate supports. System Type E(2): Membrane adhered to stress plates which are mechanically attached to structural wood supports. • • •' • • All General and System Limitations apply. Roof accessories not listed in Table f ef•tlHs NOA•Zre• not approved and shall not be installed unless said accessories demonstrate compliVtM witif prescriptive Florida Building Code requirements and are field fabricated utilizitrg'llfeapproved • membranes listed in Table 1. • •"" Fire Barrier: VersaShieldQ° Fire -Resistant Roof Deck Protection, VersaShieldltsew' Firer•„% (Optional) Resistant Slip Sheet or TOPCOAT* FireOut'" Fire Barrier CoaSri jvliplied Per manufacturer instructions. re. : 00 • • Membrane: EverGuard® TPO or EverGuard Extreme® TPO mechanically fastened usin4Di•ilT Tec' #14 Fasteners and Drill-Tec' RhinoBond® TPO XHD Pla*wc Fasteners 41V driven through the plywood roof deck and into the structural wood Supports at' described in the fastening details below. The roof cover is bonded to stress plates using the RhinoBond' Portable Bonding Tool per manufacturer's installation instructions. Weighted cooling magnets are placed over the bonded membrane/plates for a minimum of 45 seconds. Side laps are minimum 3" wide and sealed with a minimum 1.5" wide heat weld positioned on the outer edge of the lap. Fastening #1: Fasteners are driven through the wood deck and into the structural wood supports in a maximum 24 x 36 in. grid. Maximum Design Pressure: -52.5 psf (See General Limitation #7) Fastening #2: Fasteners are driven through the Wood deck and into the structural wood supports in a maximum 24 x 24 in. grid. Maxinuunt Design Pressure: -75 psf. (See General Limilalion #7) Fastening #3: Fasteners are driven through the wood deck and into the structural wood supports in a maximum 18 x 24 in. grid. Maximum Design Pressure: -82.5 psf. (See General Limilation #7) Surfacing: Chosen components must be applied in accordance with manufacturer's (Optional) application instructions. Any coating listed below used as a surfacing must be listed within a current NOA. l . EverGuard® TPO Batten Seam Profile or EverGuard® TPO Standing Seam Profile installed in accordance with manufacturer's specifications and applicable Building Codes. 2. TOPCOAT® Membrane applied at 1 to 1.5 gal./sq. 3. TOPCOAT® TPO Red Primer applied at 0.5 gal./sq. prior to applying TOPCOAT® Membrane. Maximum Design Pressure: See fastening options above. NOA No.: 15-0729.18 MIAMI•DADECOUNTY Expiration Date: 09/22/20 Approval Date: 09/10/15 Page 26 of 27 GENrRAL LIMITATIONS: I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied it approved a;pAaft* panel size shall be 4' x 4' maximum. ' • • • • 4. An overlay and/or recovery board insulation panel is required on all applications over dlbled cen fom insulations when the base sheet is fully mopped. if no recovery board is used the base slheet shall'be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.;0Qi.** iip mojmd-b ribbons in three rows, one at each side lap and one down the center of the sheet al"wir.a con( nuoVs area of ventilation. Encircling of the strips is not acceptable. A 6" break shall b&pfacea every171►1 each ribbon to allow cross ventilation. Asphalt application of either system shall trot.":iinimum Mate of 12 lbs./sq. • Note: Spot attached systems shall be limited to a maximum design pressure off`-4Spsf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (t') valve -We 275 lbf. as tested in compliance with Testing Application. Standard TAS 105. if the fastener value, as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I 1 i and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.:.15-0729.18 Expiration Date: 09/22/20 Approval Date: 09/10/15 Page 27 of 27 Membrane: — 'EverGuard® TPO' 45-mi to 60-mil or'EverGuard® Extreme"" TPO' 50-mi to 60-mil, fully adhered with 'EverGuard® #1121 Bonding Adhesive" applied at a rate of 60-ft2/gal. 5. Deck: NC Incline: 1/2 Insulation: — "EnergyGuard'"" or "EnergyGuardTM RF" or'EnergyGuardTM Ultra" or 'EnergyGuard— RA" or "EnergyGuardTM RN" or "EnergyGuardT" RH", any thickness, any combination. Membrane: — "EverGuard® TPO" 45-mil to 60-mil or "EverGuardO ExtremeTM TPO" 50-mil to 60-mil, fully adhered with 'EverGuard® #1121 Bonding Adhesive' applied at a rate of 60-ft2/gaL 1. Deck: NC Class C - Fully Adhered Incline: 1/2 Insulation: — "EnergyGuardTM' or 'EnergyGuard'" Ultra' or "EnergyGuard— RA" or "EnergyGuard— RN' or "EnergyGuardT" RH" or wood hoer or glass fiber or perlte, any thickness. Membrane: — "EverGuardO TPO," 45-mil to 60-mil or'EverGuard@ ExtremeTM TPO' 50-mil to 60-mi, fulbr adhered with "EverGuard® #1121 Bonding Adhesive" applied at a rate of 60-ft2/gal. ; 000 • • • • • • • 2. Deck: C-15/32 Incline: Unirnited • • • • Base Sheet: — One ply "VersaShield® Underlayment", mechanically fastened. � 0: " • • • Membrane: — 'EverGuard® Steep Slope TPO" 45-mil to 80-mill, fully adhered with "EverGU>lMV Steep Slope Bonding • • ••• Adhesive' applied at a rate of 1-gal./100-ft2 or'EverGuard® TPO' 45-mil to 80-mil or'EveV Extreme— APO' SO.m••ri • to 80-mil, fully adhered with "EverGuard@ #1121 Bonding Adhesive' applied at a rate of 1-gatj90Lft2 or "EverGuard@ TRO. • • FB Ultra" 45-mil to 80-mil or "EverGuard® ExtremeTM TPO FB Ultra' 50-mil to 80-mil, fully adkeiedwrith 'fiverGurard® H14 • • • Bonding Adhesive" or "EverGuard® WB 181 Bonding Adhesive" applied at a rate of 120-ft2/Jal. OP• EverGuerd•••®•F•reedom Ve • • • TPO' 45-mil to 80-mil or'EverGuard® Extreme— FreedomTM TPO HW' 50-mil to 80-mil, re , se4f adhed. • • 3. Deck: NC Incline: 1/4 • • • • • Insulation (Optional): — "EnergyGuardT " or "EnergyGuard— Ultra" or "Erie Guardor "EnergyGv � �N" or f"r "EnergyGuardTM RH" or wood fiber or glass fiber or perite, any thickness. r9y — REM' • . . • .ard• • • •: Membrane: — 'EverGuard® TPO' 45-mil to 80-mil or "EverGuard® ExtremeTM TPO' 50-mil to 80-mil, fully adhered with 'EverGuard® Low VOC TPO Bonding Adhesive" applied at a rate of 120-ft2/gal.00 SINGLE PLY MEMBRANE ROOFING SYSTEMS (TPO) Class A - Mechanically Fastened 1. Dedc: NC Incline: 1/2 Insulation:—'EnergyGuardTM" or 'Energy Guard— RF" or'EnergyGuardTM Ultra' or "EnergyGuarc" RA' or 'EnergyGuard— RN' or "EnergyGuard— RH' or wood fiber or glass fiber or perite, any thickness, mechanically fastened. Membrane: — "EverGuardO TPO" 45-mil to 80-mil or "EverGuardO Extreme— TPO" 50-mil to 80-mil, mechanically fastened. 2. Dedc: NC Incline: 2-1/2 Membrane: — "EverGuard® TPO" 45-mil to 60-mil or "EverGuardO Extreme'" TPO' 50-mil to 60-mil, mechanically fastened. 3. Deleted. 4. Deck: NC Incline: 1/2 Insulation (Optional): — "EnergyGuard—" or "EnergyGuard— RA" or "EnergyGuard'" RF" "EnergyGuard— Ultra" or "EnergyGuardTM RN" or "EnergyGuardTM RH" or wood fiber or glass fiber or perite, any thickness, mechanically fastened. Membrane: — 'EverGuardO TPO FB Ultra" 45-mil to 80-mil or'EverGuard@ Extreme'" TPO FB Ultra" 50-mil to 80-mil, mechanically fastened. t. Deck: Cy15/3 Indine:,l/2 rimer. — 'TOPCOAT®1 reQul: " FirejBaroer Coating" applied at a. rate of 1-gal./100-ft_ (Base Sheet (Optional): — One ply Type G2, mechanically fastened. SHP Sheet (Optional): — One ply "VersaShieldo 1S" or'VersaShield® 2S' or Atlas Roofing Corp. 'FR-10" or "FR-50", 6. Deck: NC Incline: 1/2 Barrier Board (Optional): — Minimum Tic -in. thick Georgia Pacific Gypsum LLC 'DensDeck® Roofboard' or'DensDeck Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" or gypsum wallboard, mechanically fastened. Slip Sheet (Optional): — One ply 'VersaShield®", mechanically fastened. Base Sheet (Optional): — One ply Type 15 or Type 30 or Type G1 orType G2, mechanically fastened or hot mopped. Membrane: — 'EverGuardO TPO" 45-mil to 80-mil or'EverGuard® Extreme'" TPO' 50-mil to 80-mill or "EverGuard® TPO FB Ultra* 45-mil to 80-mil or 'EverGuardO Extreme'" TPO FB Ultra' 50-mil to 80-mi, mechanically fastened. Surfacing: — United Solar Ovonics Field -Assembled Photovoltaic (Solar) Module Systems, 'PVL-29, -31, -58, -60, -62, -64, -68, -87, -93, -116, -120, -124, -128, -136", self -adhered. 7. Deck: C-15/32 Incline: 1/2 Sip Sheet: — Two plies 'VersaShiekl® Underlayment" or'VersaShiekl® FB-2S", mechanically fastened. Membrane: — "EverGuardO TPO FB Ultra' 45-mi to 80-m1 or"EverGuardO Extreme— TPO FB Ultra' 50-mi to 80-mil, mechanically fastened. 8. Deck: C-15/32 IncAine: 1/2 Sip Sheet: — Three pies "VersaShield® FB-IS", mechanically fastened. Insulation: — "EnergyGuardTM" or "EnergyGuardT RF" or'EnergyGuardTM Ultra; or "EnergyGuard— RA" or 'EnergyGuard— RN' or 'EnergyGuardT" RH", any thickness or any classified wood fiber board, mechanically fastened. Membrane: — *EverGuardO TPO" 45-mil to 80-mil or 'EverGuardO Extreme— TPO' 50-mil to 80-mi, mechanically • FIELD I II II II I I II II II I •I !•I 101 1.1 10 i II (I it I I If If it ! I I I I i I I I � •'• ""•• I I I I f I I l • ...... . .. ...... I I I I I I I I •••�•• . 24• I 15AM-TEC-#14 FASTENEf{,S • • l (610 mm) I I I '1?Gf e RHIN&CWQP TPCf f(W •( 1•I (•1 I I I• JR.WSAFE PLATES •• II I I I I I I •••••• t I I I I I I ! • I I I I I I I MIN. 15/32• IV mm) 1 36' 1 1 1 1 I I I PLYWOOD OR OSS I (914 mm) I I I I I I ! I it 11 II I I II I1 II I I II II II I I fl !I II 1 •! I•I i•I I•I f• I 11 II II I 1 II II II t WOOD JOISTS 24" 24" 24" 24" (610 mm) (610 mm) (610 mm) (610 mm) NaTE: 1. GRID PATTERNS WITH SECUREMENT INTO THE WOOD JOISTS ARE FOR USE OVER INSULATED OR NON -INSULATED DECKS WITH AN AREA OF 6 SO. FT. PER FASTENER. 2. VERSASHIELD°SOLeAND/OR FIREOUTTMFIRE BARRIER CAN BE USED TO ACHIEVE UL CLASS A FIRE RATING NON -INSULATED DECKS. 3. MIN. 1' (25 mm) FASTENER EMBEDMENT INTO JOIST. 4 FASTENING PATTERNS 24" X 36" (610 mm X 914 mm) ECUREMENT GRID INTO - WOOD JOISTS � RHINO sysmu I �mim pw*pww. - 52.5 PSF (105 PSF) sc.�.EOND N.T.S. � 3-15-16 I I •[ I I II II I'( 11 II it II I'i If II II II I'f II (I I i I• I I I I •I II II I•I (I II I•I II li i•I I I I• 24" (610 mm)I I I I •I I•I I•I I'I I• i II II I) I I t8" I I I I I I I I (457 mm)- I I I I I I I II [I it I •I I.1 [•I 1•I (• I II 11 II I I II II Il I ! II II I( I I II II (I I •I I•I I•I I•I 1• II II II I I I I I I I I I 24" 24" 24" 24" (610 mm) (610 mm) (610 mm) (610 mm) NOTE: •• • .. . • 0*0000 • • • • ..•... 0, • ...•. RfjCC;TEC-�14 FASTENtW •. AlU RHINQQMit TPO,40Vip.. •TRli.AASAFE PLATES 0 • . . . ...... .00 . ,0666 • •• . . ,, • - MIN. 15/32" ri`lffim) PLYWOOD OR OSB WOOD JOISTS 1. GRID PATTERNS WITH SECUREMENT INTO THE WOOD JOISTS ARE FOR USE OVER INSULATED OR NON -INSULATED DECKS WITH AN AREA OF 3 SQ. FT. PER FASTENER. 2. VERSASHIELOPSOLO'"AND/OR FIREOUT�FIRE BARRIER CAN BE USED TO ACHIEVE UL CLASS A FIRE RATING NON -INSULATED DECKS. 3. MIN. 1" (25 mm) FASTENER EMBEDMENT INTO JOIST. FASTENING PATTERNS 24" X 18" (610 mm X 457 mm) SECUREMENT GRID INTO - WOOD JOISTS om%vms RHtN SYSTEM BOND „w 07054 - 52.5 PSF (105 PSF) SCALE N.T.S. � �,5 ,s ' CORNER I �I II II 1�( lei II ICI I I! i •I I I I I I•I I•I I I I•I I I• • ; .•. '•••• • I ( I I I I I •' ICI Imo( l ...... . .. ...... �l [�I I� ...;.. :••.,: I I I I I I I I •••• • ••••• ! I I I I I I I .... . ..... •( I•I 1.1 i•I I• ••�••� :•••:• ••••• I 24• ' f _(610 I I I •DRGt-TEd"V14 FASTENMI • I mm)_l I I 1 1 1Nf 3RHINOBdkD®TPO X. P• �I I I - REAbSAFI: PLohiES 101 101 lei 10 g• ; .•. ..... 1 (229 mm) I I I I I I I •• •• • •I I•I 1.1 1.1 I• I I I 1 1 1 1 MIN. 45/32• (12 mm) I 1 1 1 I I l ! PLYWOOD OR OSB 61 I I'I I'1 II If I'I 1' sl I I•I 1.1 11 II II 1.1 II I l• t I 'l I I I I I lei I'I II I II 101 I I' of I I•I I•( [I II II I•I II I I• I WOOD JOISTS 24" 24" 24" 24" (610 mm) (610 mm) (610 mm) (610 mm) NOTE: 1. GRID PATTERNS WITH SECUREMENT INTO THE WOOD JOISTS ARE FOR USE OVER INSULATED OR NON- INSULATED DECKS WITH AN AREA OF 1.5 SO. FT. PER FASTENER. 2. VERSASHIELD°SOLd AND/OR FIREOUT'FIRE BARRIER CAN BE USED TO ACHIEVE UL CLASS A FIRE RATING NON -INSULATED DECKS. 3. MIN. 1' (25 mm) FASTENER EMBEDMENT INTO JOIST. FASTENING PATTERNS 24" X 9" (610 mm X 229 mm) ECUREMENT GRID INTO - WOOD JOISTS oRAaSYSTEM WM RHINOBOND ' w - 52.5 PSF (105 PSF) N.T.S. ISSMREVOM 3-15-16 .,...b....., __5.. u....... MIAMI`DADE "Delivering Excellence Every Day" Roof Mean Height 10 it Miami -Dade County HVHZ Electronic Roof Permit Form Single Ply Membrane Edge Metal Detail Edge Metal Cleat - N/a % INNOW WINE Approved Sealaid ..- .. *Goose • •• •••••• :..�:�f� ....:_._.: __ - sG•••• G • •Goo• 00090 •• •• • •••G•• . .. - 000000 • • -°v'"5 Adhei ed Single G • G • • G •00 • '' rt •; Ply Membrane Strip G • •-,•��_4.'•� Approved Fasteners '�'• �= =; Mechanically Fastened or Adhered Single Ply Membrane i Pt Wood Nailer Roof Deck Provide Component Information Edge Metal Type and Size: 126 Ga Galvanized metal - 3"x3" I Continuous Cleat: I n/a Surfacing: n/a-- Single Ply Membrane Type: I GAF Everguard TPO - 60mil Top Insulation Layer Type: I n/a Base Insulation Layer Type: I n/a Wood Nailer Type & Size: 12x6 PT nailer Wood Nailer Attachment: 1/4" Diameter masonry anchors, anchored to block wall Deck Type; 5/6" CDX plywood