RF-19-2832ACB2 Engineering Inc. Testing & Engineering Service Certificate of Authorization # 8131 Tel: 954.245.8976; Fax: 954.301.7776 5230 NE 18 Avenue, Fort Lauderdale, FI 33334 Roof Tile Uplift Test Report Attention: Miami Shores Village, Building Department 10050 NE 2nd Ave, Miami Shores, FL 33138 Client: AK Roofing Inc. Test Date: 02/26/2020 Permit # RF-11-19-2832 Property Address: 235 NE 911Street, Miami Shores, FI Roof Pitch: Type of Tile: Roof'Area: 3 in 12 Eagle Roof Tile 24.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive -Poly Pro AH 160 Field Instrument : IMADA Force Gauge 0-100 Serial number: 243454 Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: 10.00(Tl-T10) 10 As per FBC 2017 Passed Field Area: 14.00(T11-T24) 14 As per FBC 2017 Passed No. of Corner: 6 (T25-T30) 6 As per FBC 2017 Passed Ridge Areas: 126 pcs. (T31-T43) 13 As per FBC 2017 Passed Important: These laboratory results can change due to future weather impacts and/or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. Cordially, ACB2�Engineering Inc. (NOA 09-1005.01) A,uidi Acevedo, PE Fia_/Aeg. No: 36466 6 4'9q'?'7' ACB2 Engineering Inc. Engineering and Laboratory Services 5230 NE 1811 Avenue Fort Lauderdale, Florida 33334 Phone: (954) 245-8976 Fax: (954) 301-7776 zs 16 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit INSPECTION AFFIDAVIT DATE: 14 11cp °I _ h i e :R-a a n licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) FS 468 Building Inspector License #: (C c d S E0 S 1 On or about t 1 / / (,p // C-/, , I did personally inspect the roof deck nailing (Date & time) �� work at 9SS AJE 9 1 ��T'l- r W,-I I' S�LgYe S (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this Notary Public, Sate of Florida at Large day of :r"C (Y)b _Y- / OAO 101 Yecenia Santibanez �OSpRYq NOTARY PUBLIC ae ESTATE OF FLORIDA ? Comm# GG115152 Expires 6/14/2021 'General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # dearly shown marked on the deck for each inspection Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date:12/03/2019 Location Address Parcel Number 235 NE 91ST ST, Miami Shores, FL 33138 1132060133440 Contacts Permit NO.: RF-11-19-2832 Permit Type: Roof Work Classification: Tile/Flat Permit Status: Approved Expiration: 06/01/2020 MARIANNA HYNSON Owner J&K ROOFING INC Contractor 962 ELDORADO DR, SUPERIOR, CO 80027 DONNIE HERRON SAME AS ABOVE Business: 9549617663 Description: TILE AND FLAT REROOF Valuation: $ 29,400.00 Inspection Requests: 305-762-4949 Total Sq Feet: 3,600.00 Fees Amount Application Fee - Other $50.00 CCF $18.00 DBPR Fee $4.88 DCA Fee $3.25 Education Surcharge $6.00 Roofing Fee $275.00 Scanning Fee $12.00 Technology Fee $8.13 Total: $377.26 Payments Date Paid Amt Paid Total Fees $377.26 Check # 1135 11/26/2019 $50.00 Check # 1136 12/03/2019 $327.26 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / - Date December 03, 2019 Page 2 of 2 i j RECEIVED '9\`0 Miami Shores Village No 2 6 204 By:BuiIding Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC 0 ROOFING []PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: 235 NE 91 ST I FBC 20 Master Permit No. - 2 &3 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL s [] CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS Folio/Parcei#:11-3206-013-3440 Is the Budding Historically Designated: Yes NO Occupancy Type: Load: i Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): MARIANNA HYNSON Phone#:305-505-4555 Address:962 ELDORADO DR 6 City;SUPERIOR ! State: CO Z;p; 80027 Tcnant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: J&K Roofing Inc. r Phone#: 954�_ 2&11k� % Address: 2010 Sherman St City: Hollywood State: FL ip: 33020 Z Qualifier Name: Donnie Herron Phone#: 984-980-2205 State Certification or Registration* C_C.C_0&3_4R OS 1 Certificate of Competency M DESIGNER: Architect/Engineer: 4 Phone#: Address: qq ' y� I City: State: Zip: Value of Work for this Permit: $ oc ( o o - Q a Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New Q Repair/Replace ❑ Demolition Description of Work: Tile and Flat reroof Specify color of color thru tile:_ j�iq 114a I i J2p 52 c,�o o Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Educatlon Fee $ i Double Fee $ Structural Reviews $ Bond $ (Revlsed02/24/2014) TOTAL FEE NOW DUE $-3 Bonding Company's Name (if applicable) Bonding Company's Address City F,Ik State Mortgage Lender's Name (if applicable) Mortgage Lender's Address N L UL City -TT State Zip 9 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to -meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... r i OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. r "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspecting, v✓hich occurs seven (7) days after the building permit is issued. in the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Sn ature Signature �1/ Gryvl�i� r OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this ._V day of Or 1 20 by day of N Dy 120 ---� by o is personally known to who is personally known to me or who has produced /f me or' who has produced as s identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTAFRY PUBLIC: Sign: Sign: t % Print: lk i Print: Seal: NOTARY PUBLIC - STATE OF COLORADO 4 Seal: J. Commission # GG 355189 NOTARY ID 20114023441 'a Expires November 13, 2023 MY COMMISSION EXPIRES APR 22, 2023 Bonded ThruTroy Fain insurance 800.385.7019 t 1I s APPROVED BY Plans Examiner, Zoning I Structural Review Clerk i (Revised02/24/2014) %A. o F F I C E .. OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-013-3440 235 NE 91 ST Property Address: Miami Shores, FL 33138-3127 MARIANNA HYNSON & Owner ALEXANDRE MAXIMIANO 962 ELDORADO DR Mailing Address SUPERIOR, CO 80027 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ 0101 RESIDENTIAL -SINGLE Primary Land Use FAMILY: 1 UNIT Beds I Baths / Half 4/3/0 Floors 1 Living Units 1 Actual Area 2,920 Sq.Ft Living Area 2,297 Sq.Ft Adjusted Area 2,549 Sq.Ft 13,100 Sq.Ft Multiple (See Building Info.) Lot Size Year Built Assessment Information Year Land Value Building Value 2019 2018 2017 $353,254 $301,300 $353,254 $177,784 $177,837 $177,890 XF Value $1,534 $1,560 $1,586 $532,730 $485,711 Market Value Assessed Value $532,572 $528,766 $480,697 $480,697 Benefits Information Benefit I Type 1 2019 2018 2017 Non -Homestead Cap Assessment Reduction 1 $3,806 1 $47,019 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Generated On : 11/11/2019 Taxable Value Information 20191 2018 2017 County Exemption Value $0 $0 $0 Taxable Value $528,766 $480,697 $485,711 School Board Exemption Value $0 $0 $0 Taxable Value $532,572 $480,697 $532,730 City Exemption Value $0 $0 $0 Taxable Value $528,766 $480,697 $485,711 Regional Exemption Value $0 $0 $0 Taxable Value 1 $528,766 $480,697 $485,711 Sales Information Previous Sale 08/01/2002 06/01/1972 Price $311,000 $56,000 OR Book -Page Qualification Description Sales which are qualified Sales which are qualified 20617-3566 00000-00000 Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOTS 15 & 16 BILK 25 LOT SIZE 100.000 X 131 OR 20617-3566 08/2002 1 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:i/www.miamidade.gov/info/disciaimer.asp Version: R RICK •GOVERNOR JONATHAN r' r bier; STATE OF FLORIDA DEPARTMENT OF. BUSIN.. FESSIONAL REGULATION * r THE •OO)FIN �, S . +\ '' ; I� y.l Lam' _ �UNDERTHE 1�• • • • UTIES r Always verify lidenses 1 rw Y •. 4 �, '��y1f 1� �•w -,.ram l .r . ,� fi F;:.�=.�rti.,• �•'r online MyFloddaLicense.com This Is your license. It Is unlawful for anyone other than the licensee to use this document Do not alter this document In any form. ❑ 1064 Local Business Tax Receipt Miami —Dade County, State of Florida -THIS IS NOT A BILL - DO NOT PAY 4247763 BUSINESSNAt MCAMON RECEWTNO. EXPIRES J & K ROOFING INC RENEWAL SEPTEMBER 30, 2020 DOING BUS IN DADE CG 4434908 Must be displayed at place of business MIAMI FL 33000 Pursuant to County Code Chapter SA - Art. 9 & 10 OWNIER IECOM I"RMNG INC 196 PECIAALLTY BUILDING CONTRACTOR �� BTTAXCBLLFCfOR CCCO58051 $75.00 07/11/2019 Worker(s) 5 CHECK21-19-052995 This Local Business Tex Receipt aah cools es p 7maR of the Local Business Tex. The Receipt is not a license, Warne"W��� holder'sogulatowy aad r ligairrioie�whichhippplyytio Holder es ePM 9oremeeafal The RECEIPT No. above must he displayed on all coalmeralal vehicles - Misn"ade Code Sac la-M For more hdarmation, visit ACORa CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION PTS Insurance ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR 7735 NW 146 Street C-100 ALTER THE COVERAGE A D BY THE POLICIES BELOW, Miami Lakes, F1 33016 305-818-9544 INSURERSAFFORDING COVERAGE NAIC # INSURED J & K Roofing, Inc. INSURERA Watford SRecialty Ins Co 15824 INSURER R INSURERC: 2010 Sherman Street INSURERD: Hollywood, FL 33020 INSURER E Cf1VFRAf:1=C THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR NSRD POLICY NUMBER POLICY EFFECTIVE POLICY EXPIRATION LIMITS A GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY CLAIMS MADE 10OCCUR $5000 DED PD BRCGL0005901-01 11/15/19 11/15/20 EACH OCCURRENCE $ 1,000,000 MED EXP (My one Person) $ 100,000 $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2.000,000 GEN'L AGGREGATE POLICY LIMIT APPLIES PER: LOC PRODUCTS-COMP/OPAGG $ 2.000,000 PRO C ber Liab A100,000 AUTOMOBILE LIABILITY ANYAUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON-OWNEDAUTOS COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILYINJURY (Peraccident) $ PROPERTY DAMAGE (Peraccident) $ GARAGELIABILITY ANYAUTO AUTO ONLY - EA ACCIDENT $ OTHER THAN EA ACC AUTOONLY: AGG $ $ EXCESS/UMBRELLA LIABILITY OCCUR CLAIMSMADE DEDUCTIBLE RETENTION $ EACH OCCURRENCE $ AGGREGATE $ $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? Ifyes, desaibeundi rONS below E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ OTHER DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT / SPECIAL PROVISIONS Roofing Operations CERTIFICATE HOLDER CANCELLATION Miami Shores SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN 10050 NE 2nd Ave Miami Shores, Fl 33138 NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL 305-795-2204 IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR 305-756-8972 (F) REPRESENTATIVES. AUTHORIZED REPRESENTATIVE ACORD25 (2001/08) �C A CORD CORPORATION • CERTIFICATE OF LIABILITY INSURANCE Date 12/17/2018 Producer: Plymouth Insurance Agency This Certificate is issued as a matter of information only and confers no 2739 U.S. Highway 19 N. Holiday, FL 34691 rights upon the Certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. (727) 938-5562 Insurers Affording Coverage NAIC # insured: South East Personnel Leasing, Inc. & Subsidiaries Insurer A: Lion Insurance Company 11075 InsurerB: 2739 U.S. Highway 19 N. Holiday, FL 34691 Insurer Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement, tens or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date Policy Expiration Date Limits (MM/DD/YY) (MM/DD/YY) GENERAL LIABILITY Each Occurrence b Commercial General Liability Claims Made Occur Damage to rented premises (EA occurrence) Med Exp Personal Adv Injury General aggregate limit applies per: Policy ❑ Project ❑ LOC General Aggregate Products - Comp/Op A99 AUTOMOBILE LIABILITY Combined Single Limit (EA Accident) $ Any Auto Bodily Injury All Owned Autos (Per Person) Scheduled Autos Bodily Injury Hired Autos Non -Owned Autos (Per Accident) Property Damage (Per Accident) EXCESS/UMBRELLA LIABILITY Each Occurrence Occur ❑ Claims Made Aggregate Deductible A Workers Compensation and WC 71949 01/01/2019 01/01/2020 X WC Statu- I OTH- Employers' Liability tory Limits ER E.L. Each Accident $1,000,000 Any proprietor/partner/executive officer/member E.L. Disease - Ea Employee $1,000,000 excluded? NO If Yes, describe under special provisions below. E.L. Disease -Policy Limits 31,000,000 Other Lion Insurance company is A.M. Best Company rated A (Excellent). AMB # 12616 Descriptions of Operations/Locations/Vehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 92-68-239 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company": I & K Roofing, Inc Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or email certificates@lionlnsurancecompany.com Project Name: ISSUE 01-13-15 (TLD)REISSUE 01-04-16 (AF) Bealn Date: 2 20 2014 CERTIFICATE HOLDER CANCELLATION VILLAGE OF MIAMI SHORES Should any of the above described policies be cancelled before the expiration date thereof, the Issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any Idnd upon the insurer, its agents or representatives. 10050 NE 2ND AVE MIAMI SHORES, FL 33138-r•� r =� --� �_ LICENSED AND INSURED LICENSE # CC-CO59051 2010 Sherman Street Hollywood, Florida 33020 ROOF1-N-G Sor«dwj S-a 574-la 0ass'0- 30 gfearo 954-981-7663 954-961-9879' Fax 9S4-9254015 SdbetuedTa y, J bN— Diu Ail Sell spy � Phodc I CI(A SL & TIp t /' 1/� qtr St a Zip P6eee 2 MLWIZI �.Gm Lor Rik Sub T. RAW ALL ROOFS TO BE DONE AS FOLLOWS E SLOPE ROOF [3 FLAT ROOF Will tear off entire existing slope. Roof down to deck or smooth workable surface. WILL RENAIL DECKING TO MEET EXISTING CODE Remove all related roofing debris from premise& ftepVe any necessary wood. y5 O LF, or sq. tt for plywood fre ' y dperftthereafter. Will apply 30 lb. premium felt, anchored to the deck. according to local building code. Will Instalf aft new metal flashing and lead stacks. USING HOT ASPHALT, MOP a 36 INCH WIDE STRIP OF 30 LB FELT VERTICALLY AND a 1g INCH WIDE GALV. VALLEYMETAL INALL VALLEYS. Mop with Hot Asphalt R to said 301b's. Embed "50 16, tile in P el y rff mr .,,ten,. Will tear off entire existing flat roof down to deck or smooth workable surface. WILL RENAIL DECKING TO MEET EXISTING CODE. Remove all related roofing debris from. premises. Rep any necessary wood,^LF, or Sq. ft for plywood iO perfl thereafte►. Will apply 1 ply 6(2S..basesheet anchored to the deck according to local buildlTgcode. Using HOT ASPHALT, will mop _yZ,,-ptys of fiberglass felts to said basesheet Install all new metal flashing and lead stacks. .Using HOT ASPHALT mop 1 ply fiberglass cap sheet to said fiber9glass. B E said fiberglass felt. d r We hereby propose to furnish labor and materials - complete in accordance with the above specifications, for the sum of dollars n��G(%O ) with payment to be made as follows: I i .5.0 0 20 .In u/4>;n aG��c��,� t w� r-r�,rs�,�, '0!yAm, ca�,,io No carpentry work, woodwork or painting unless specifically stated in this Contract. !'. M the event paylmeflt is t of nNkaiaylr, .lg ml �t�l�dya 1pW urlywin couoctfons, gui era,. . but not limited to, attorney fees, court costs an collection ageec es—, a_re £o be paid by signer oP owner. COVERAGE The roof applied to the building described above Is guaranteed for _ years iron the date of.crapiction upon final payment in full. This guarantee is TRANSFERABLE AT NO CHARGE to new owners of the property. Under this guarar!lse, the rodnng contractor will, at Its own expense, males any repairs necessary to correct roof leaks resulting from it* following causes: 1. Failure of rooting felts or base flashing resulting from usual and ordinary effects of wear and weather. 2. Poor workmanship of roofing contractor In applying roofing and flashing materials Method of Payment: CHECK EXCLUSIONS /7 01 k WH MONEY ORDER This guarantee does not cover. 1. Leaks or other damage caused by: S .Q CREDIT CARD a. Natural disasters, including but not limited to floods, lightning, hurricanes, hail, windstormsfauthquakes, tornAos, dry rot, etc. b. Structural failures such as sacks In decks, walls, partitions, foundations, windows, stoppage of roof drains or gutters, etc. c. Changes in the original principal usage to which of the building, unless approved by the contractor in advance In writing. d, Erection or construction of any additional installation on or through the roofing felt after the data of completion. e. Roof or flashing repairs by others, painting or coating without approval. T Riots or vandalism_ % Tem#tas or other Insects. h. Penetration of the roofingiron beneath by rising nals. 2. Damage to the building or Its contends, roof insulation, roof deck or'other bass over which roofing fell is applied. ACTION In the event lealm from roofing should occur, owner shot notify contractor pronrptiy. contractor will Inspect the roof, and If cause of leak is within the coverage as shed above, the contractor wig arrange for repairs to be mad. at no cost to the owner. if cause of leak is not covered, contractor wig not be responsible for cod.of any repairs. In the event leaks are not covered under the terms of this guanmise, a service charge will be in Volced to the owner. The guarantee will become nut and void Ifpsyment of the service charge is not made within 30 days of the billing date. WE MAKE NO GUARANTEES OFANY KIND, EXPRESSED OR IMPLIED, EXCEPTAS STATED HEREIN. ACCEPTANCE OF PROPOSAL: The above prices, specificatio1AhoTbzd NATURE and conditions are an) by accepted. You ae0 satisfactory and hero authorized to do the work as specified. Psyment will be made aNMRE outlined above. t have mad 3 understand the back of this eontrnsr) I understand the wood Clause. S J .,/ .—/L W-4— DATE ROOF DES AND ROOFTOP STRUCTURES !� Radda Building Cade 6th Edition (Zoi ' • • • • • • • t• • High -Velocity Hurricane Zone UnMorm permit 11 • . • • • • • • ' ! - Application FQrM�• ....,. Section A.(General Information) • • • • • ..' ....� Master Permit No. _ • • • • • • .... • Process No. .•.... •.�• ••••� n....;. Contractor's Name • • • • • • Z • Job Address aJ /U� Sf • • • • ROOF CATEGORY • • 1 Low Slope Cl Medranicaily Fastened Tile �f 1 1� Mortar/Adhesive Set Tiles , ❑ Asphaltic Shingles ❑ Metal Panelftk Res /❑ Wood Shingles/Shakes 1 ❑ Prescriptive BUR-RAS 150 1 ROOF TYPE 1 ❑ New roof ❑ Repair ❑ Maintenance j Reroofing ❑ Recovering 1 ROOF SYSTEM INFORMA 7 1 Low Slope Roof Area (SF) LO 0 Steep Sloped Roof AREA (SSE, Total (SFj J t`2 1 Sketch Roof Plan Illustrate all levels and ^ sions of sections and levels. dearly identil _-A 1. L 1-=.J J--I- Section B (Roof Plan) �e � ') &, C, S i 1 1 1 r and overflow drains. Include dimes- 1 lion of parapets. , 1 i - -- - - - - --- - - - 1 -- i Aal. A 0 P mrin _ 1 I , Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Slowed Roof SvStem) ; ...: • FM In Spedflc Roof Assembly Cw"nesuts and identify Manufacturer (Na am potent is not used men* as •NAI Sysben, waactuner. C A r WANo: -le- Fasbner Sparing for AnchouiBass i" ; • Attachment 66 0:0, Fiekt ' oc Q Lap. # ltoyrs r2 • j •roc • • • Perimeter. -_& ' oc @ Lap, # Rowa ' oc • i •' • coiner: -�—• oc @ Lap. # Rows oc • Design Wind Pressures, From MS In or Calculations: • 7 L v�. ' �- ~ -Ner dmbof Fasteners Per insutadon • Prrmxt- Pmax2�_PvTwOO: -Ward • .. Max. Design Pressure. FMM the Spedticc NOA ja s Systeff Dad` wD D J TYW ie�cna�a� ArwtwrBase Sheet & No. of Py(s)-,,._ Andwr/Base Sheet Fadenwfilon ft Material: insulation Base Layer.. Base Insulation Size and Thicimew. Base Initiation FastenerfBo Wft Material: Top Insulation Layer, Top Irreul w Size and T1*kMss: Top Iron, FasteaerrBMXWM Material: 111v-1 •.•• Field Perimeter Corner Ukmtrate Components Noted and Details as Applicable: WoodModit, Gutter, Edge Termination. Stripping. Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Fleshing. Coping, Etc. Indluft Mean Roof Height, Parapet Height. Height of Base Flashing, Component Materiel, Material Thidu,ess, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. A, �A n'\\ Ca�ns�.ze Base Shset(s) a No. Or Ply(s): /- #?s A$Se thee+ Ply Sheet(s),& No. /off Pllyy((isn)-, Ply Fes AE3a�52 Top Ply: r wood 2 1W Height FT. Mean Roof Height RWASSENU i S AND ROOFFOP SFIMCTUM • .... % F B&Wd/ng CodeNh EdWon CM7) • MigMYelocityWMI1101OW Zone th*orrn Permit Application FOipi� .. • • • • �• �•..... :�• :....Y Section D (Steep Sloped Roar n) "" • • . ' '•.• Roof System Mmub*ffer. Q ...... • • • • •� Notkre of AwepWwe Number. ��' !%r0 ( • • Mininwan Design Wind Pr+essutes, ff (From HAS 127 or Ca s): • • :.... . P1: Pi: P1: 4 - • • ' Roof Slope: 3 12 - Ridge Veritla ' ? 1 - i De* Type: t 1 _ 1 \ Type Undaiayment Ty,.-O 30l�b 1 1 Insuladon: �} 1 - - 1 Fire Bander: I'JAA 1 Fastener Type & Spacing: /,w.4K `ZO °[ 1 ,A 1 Adhesive Type: -fyAe 0 Type Cap Sheet 11,91h �;ii c,HJil.w�M,P J 1 Mean Roof Height: %� t Roof Covering: Mediv,, P-O Q n ncd�� Type & Sipe Drip 3X3 aG c C1a Edge: 1 eAVt C)6P 14)l//�9'" PUS 1 n)a;`S ` - Otc 1 RAmm an DM CODE — BULDM ft EDIi10N (2M7j ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 1 l I 1 1 { i 1 1 1 1 1 1 i 1 1 1 1 i 1 1 i i t 1 1 1 1 1 1 1 1 1 1 1 1 1 i { Florida 80*90tg Code 6th Edition (2017) • . • ...... High -Velocity Hurricane Zone Unfform Permit AppitaadOn Form • • - • 600666 ...... Section E Mle Celculetions) • 0009 0 0 •' • • • For Moment based file li�Ot , choose either Method 1 or 2. Compare the values for M, with the valuesn M,. if the• IJ4 values. .... • are greater than or equal to the M, values, for each area of the roof, then the the attachment method IsbRW ible. 60660 :..:.. Method 1 'Momentftaed Tile Calculations Per RAS 127' d = g; d &I = M,, �7 Product Approval M, ___�_ __� :� Product Approval M, .0 0 1 �0 0 ....: (P3:/DO •mod =,2 � — Mg: (�,ltj �= M,� al 7� Product Approval M, / •.:..' • Method 20Simplified Tile Calculations Per Table Below' _ Required Moment of Resistance (M,) From Table Below _ Product Approval M, 79 M, required Moment Resistance' Mean Roof Height Roof Slope 15, 2(Y 25' 30, 40' 2.12 34.4 36.5 382 39.7 42.2 3-12 322 36.0 37.4 -39.8 412 30.4 322 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30-5 32.4 7.12 24.4 25.9 27.1 28.2 30.0 'Must be used in conjunction with a list of moment based file systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based the systems use Method 3. Compared the values for F with the values for Fr. If the P values are greater than or equal to the Fr values, for each area of the roof, then the file attachment method is acceptable. Method 3'Uprrft Based Tile Calculations Per RAS 127 (Pi: x L = x w. = _j— W: x cos 6 = F„ Product Approval F (132: x L = x w. = _ )— W: x cos 6 = F,2Product Approval F (P3: x L = x w: = _) — W: x cos 9 = F,3 Product Approval F Where to Obtain Information Desoriptlon Symbol Where to find Design Pressure Pi or P2 or P3 RAS iv Table 1 or by an engineering analysis pre - pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier IL Product Approval Restoring Moment due to Gravity Mo Product Approval Attachment Resistance M, Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance P Product Approval Required Uplift Resistance F, Calculated Average Ile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the fime of permit application. 472 R.ORIDA BUILDING CODE — BUILDING, 6th EWM (2017) ROOF TO:WALL CONNECTION HURRICANE MItIG BUILT SINGLE FAMILY •RESIDEF PERSUANT To SECN latTrti • • 'IE • • • • • • ore ' lade• • 00% 6V1tc": Dep'ctme3t• •: `i0050 14.E.21,d Av - OR.*§hores' 4frida 3MIM • • • . • . • • Tel: b5)0795.=4: • : Fax:,(30� ....•• EXEMPTION" • ••::;• ....0 )�tRETROFIT' FOR EXISTING_SRE. LSTRUCTURES A414-R& 1 To: Miami Shores llage Building Department 10050 NE 2^w Ave Date: Miami Shores, Fl 33138 Re: Owner's Name:l4r�ann.ta. Yl�� Property Address: @C_ �!_ `— Roofing Permit Number Dear Building OMcial: j. t On� � w certify that I am nolrequired to retrofit the roof to waft connections of my building because:. , - o The just valuation for the structure for purpose ad valorematin is less than $3000t0-` 00;,Please:aftach proof of ad valorem taxation. o The building was constructed in cdurprance uvith the provisions. f the Florida B&1lding Code (FBC) or with,the provisions of 1994 edition of the South Florida Building Code (19W SFBC) p Signature arint Name j State -of Florida County of Dade The undersigned, being,.the frrst.duly sworn; drov and'says thathelshe is the°owner for.thevabove Swom to acid subscribed before. me this. p g0n�' I /� � day ° No p"� nweiOf�• oli*kK.v I Lary CINDY 8 STEINHARDT I�r Wida` at Large NOTARY PUBLIC - STATE OF COLORADo • IAilrn the juat vsduefion of tha stncgxe por DplDpse � ed YBbtEn1 ta�®linn is egwf to or SFBC Then you must pm" a pudding hm a corks! (tlr die R Reu w on sair 009 NOTARY ID 20114023441 MY COMMISSION EXPIRES APR 22. 2023 r= Itlen � o0 =AQ and the bU&ft Wa r�C MI• B91 Mrb Wad CMMd M HUntMe Mi gafton. r n 2 ♦Sho!R Miami Shores Village move Bui1d1n9:Depaftment:- ..%t0050 WtWcl Avgpph• INAA Shores, Florida 30138 • �lORiDA Tel: t3051 79512W: • • • • Fax%05) 756.69� • ... . 0. ...... AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HUhR1CFANE•MITlGATIQ.N; . • ...... RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURE �-PVRSjAftT ... TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Property Address: Roofing Permit Nu Dear Building Official: property as require4 boqe Manual cif Hurricane Structures as adoptei b� ft.,Florida Puilding Com Signature State of Florida County of Dade that hhave imprXed the roof to wall connections of the referenced for Exiling Site -Built Single Family Residential ion.KRule 913-3.047 FkA.C. Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of 20 Notary Public, Sate of Florida at Large (SEAL) FINAL COMPLIANCE Revised on 5121/2009 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFJNG CONSIDERATIONS :***Go •• • • • • 1524.1 Scope. As it pertains to the section it is the responsibility of roofingconfractorte • • * • • • • pfi�ltie the bwner with "' •' • the required roofing permit, and to explain to the owner the content of the section. The pfftldhs of Section R4402 :....: govern the minimum requirements and standards of the industry for roofing system installldtl'o%. Addil6roalli,.the following items should be addressed as part of the agreement between the owner ant the M tractor. thQ�vner's • initial in the designated space indicates that the item has been explained. e I .. .. .. . ..:... Renailing wood decks: When replacing roofing, the existing wood roef deck r3d�Rave to be renailed in accordance with the current provisions of Section R4403. (The rb9Ve& is usually. • :" , concealed prior to removing the existing roof system). • Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural a roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. i 4K6..7"1 Overflow scuppers (wail outlets): It is required that rainwater flows off so that the roof is —not ov loaded from a buildup of water. Perimeterledge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. t r O ner/Agent'g Signature Date t Contractor Signature Date 'Property Address I Permit Number Revised on 7/9/2009 LD;07/01/2015; rN LAM MIAM-DARE COUNIT no PRODUCT CONTROL sECTION 11805 SW 26 Sftd, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (REIN Miami, Florida 33175-2474 BOARD AND CODE ADRE STRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) WwwmIwWdade gev/wonomv GAF 1 Campos Drive Parsippany, NJ 07054 COPE: •••••• • This NOA is being issued under the applicable rules and regulations governing the use otmnstructign • • materials. The documentation submitted has been reviewed and accepted by Miami Da*.G9ft* Product Control Section to be used in Miami Dade County and other areas where allovw Aby!he Antbo�rit� Having Jurisdiction (AHJ). ..' ..' ..' . This NOA shall not be valid after the expiration date stated below. The Miami Dade Ceun{y i'roduat • Control Section (In Muni Dade County) and/or the AHJ (in areas other than Miami Dade 0gunty) • reserve the right to have this product or material tested for quality assurance purposes. If this'produLt of . material fails to perform in the accepted manner, the manufiwturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction REP, reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRiP'i'ION: GAF Conventional Bahl Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and following statement: "Miami Dade County product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manuiacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTMEAMM: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the mare fachm or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1030.01and consists of pages 1 through 27. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.:18-0919.07 Expiration Date: WNW Approval Date: 11/08/18 Page 1 of 27 Membrane Type: BUR Deck Type 1I: Wood, Non Insulated Deck Description: Min.15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c., at max. System Type E(3): Anchor sheet mechanically attached to roof deck All General and System Limitations shall apply. Fire Battler: TOPCOAT FireOutn' firfIN,, %An ating, VersaShield° Fire'-Roioant Sjip Sheet or , (optional) VersaShield° Solo Fire-Resistanf'Slip Sheet installed per maarr£srturer'l M9'thllation.... instructions. ...... 0. Anchor sheet: ...... GAFGLAS° #75 Base Sheet, Tri-Ply° #75 Base Sheet, RubeftO..20 Smdoth qr• .... GAFGLAS° Stratavent° Venting Nailable Base Sheet is secumd.amlescn'bcAbelow... ; .. • Fastening .00 Miami Dade County Approved min. 12 ga. annular ring shaa]ilsand mm J-6 in. - Option #l: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide &chbrhheet side laps and 8.. in. o.c. in the field of the sheet in two staggered rows. : • s ' Pressure• —4S sf. See General UwUado%-#7)- . • • • Fastening Miami Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Mwdmum Design Pressure: 525 psf. See General Lunitation #7) Fastening Drill -Tee"' #14 Fasteners and DrillTee"' 3 in. Standard Steel Plates, Drill -Tee Option #3: AccuTrac° Flat Plates or Drill Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min.. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Mwdmurn Design Pressu► S25 psj.' See General LbdtaBon #7) Fastening Drill Tec #14 Fasteners and DrillTech' 3 in. Standard Steel Plates, Drill Tee"' Option #4: AccuTrac° Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maxbxmw Design P un:—60pisf. Sae General Liuritadon #7) Fastening DnU Tec #14 Fasteners and Drill Tee'" 3 in. Standard Steel Plates, Drill -Ted — Option #5: AccuTrae Flat Plates or Drill Tee' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min_ 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Mwarn Design Aeswm —97.S psj.' See General Lindttaden #7) Ply Sheet: When optional cap sheet is present: or more plies of GAFGLAS°_Ply 4.,,_Tri -Ply* Ply 4, GAFGLAS° Flex Ply 6 adhered in as fall mopping of hot asphalt applied at 20-40 lbsJsq. installed per mamrfacturer's rnstaIlahon mstruchons_ When optional cap sheet is not present: Three or more plies of GAFGLAS° Ply 4, Tn-Ply* Ply 4, GAFGLAS° Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-401bsJsq. installed per manufacturer's installation instructions. NOA No.:18-0919.07 Qotmnr Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 23 of 27 Cap Sheet: (Optional) GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCap�i &if32EFed Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbsJsq. installed per mars facturer's mstallabon in chons. Snrfadng� Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to mannfictarer•s application Instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bsJsq. and 300 lbsJsq. respectively in a flood cogt of approved asphalt at 60 lbsJsq. • • • • • • 2. Topcoats Membrane or Topcoats Surface Seal SB applied at j.t � gal. • : • ' • . OR ...... Topcoats MB Plus applied at 03 to 0.75 galJsq.(to be used as 8.p4mer) Wowed by Topcoato Membrane applied at 0.5 to 0.75 .... : ' ' galJsq. .. ..... ...... ..... 3. Fiber Aluminum Roof Coating. .. .. ....•.. . ...... Maximum Design • Pressure: . . . . ...... See Fastening Above. • • • • • • . ...... NOA No.:1"19.07 Expiration Date: 11/04/23 Approval Date: 11/09/18 Page 24 of 27 WOOD DECK SYSTEM LI IITATIQNS: 1 A slip sheet is required with GAFGLASO Ply 4 and GAFGLAS® Flex Ply' 6 when used as a mechanically fastened base of anchor sheet. 2. Minimum V4- DensDeck"' Roof Hoard or'r Type X gypsum board is acceptable to be installed directly over the wood deck GENERAL UwTATIONs: •090:0 1. Fire classification is not part of" acceptance; refer #*- &&lent Approved Roofing Matai"i Du�ectory for firs "' : ratings of this product • 000000 .00000 la yer 2. Insulation maybe installed in multiple layers. The first 1 er shall be attached in comPli�tlil a with Product Control multiple Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applio&within the: "" EVT range and at a rate of 20A0 lbsJsq., or mechanically attached using the fastening pattern of the top4ayer • • : • • 3. All standard panel sizes are acceptable for mechanical attachment When applied in ash "d asphOC Ql acl size • • . shall be 4'x Vmaximum •• •• •• • •••••• 4. An overlayand/or recovery "; ' very board insulation panel is required on all applications over glosec� Fell fcpm igsulatiops� when the base sheet is fully mopped if no recovery board is used the base sheet shall he applied usM$ *6t mopping with approved asphalt; 12" diameter circles, 24" o.c.; or strip mopped 8" nbboes in three sowspone at : " " each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircli4g at the strips is not acceptable. A 6" break shall be placed every IT in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limited to a maid um design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure Imitation listed shall be applicable to all roofpressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.:18.0919.07 Expiration Date: 11/04/23 Approval Date: 11AWIS Page 27 of 27 10/18=6 TGFU.R14153- Roofing Syslenns TGFUA14153 Roofing Systems BottomPam Roofing Systems GAF 1 CAMPUS DR PARSIPPANy M 07054 USA •.•JLi41S3 .••••• ••••.• • "Ruberdd® 20' or "Ruberoid® 20 Hr or'Ruberold® Modified Base Sheer may be utilized as an albemaba to type G2 b;m sheets in an; e'6 • the following Classifications • • • • Y • • • • • • • • • • • • • 1/2-In. thick (minimum) gypsum board or 114-4n. thick (minimum) Georgia-Pacific Gypsum LLC "DensDectVjddfboard," "DensDeck Primp Roofboard' or'DensDedc DuraGuard' Roofboard' may be used in any existing noncombustible deck Classification. When this is done, t1w • • • resulting roofing system is acceptable for use over combustible (15/32-in. thick minimum) roof decks. Hovpver,.the butt jb H In the gypsuin, board and Georgia-Pacific Gypsum LLC "DensDedk® Roofboard," "DersDedc Prime® Roofboard" or'DensDWD jraGuaq1TM Bpolboardu Ore to offset a minimum of 6-In. with the butt joints In the roof deck. if polystyrene is part of the roof system, it must be placed beJ6w lire overiayment hoard.0000 Multiple plies of 'GAFGLAS® Ply 4' or "Tri-Ply® Ply 4" or "TA -Ply® Ply 6' may be adhered to Georgia-Pacific Gypsum LLC 'DensDedc Roofboard,' "DensDedk Prime® Roofboard' or 'DensDedc DuraGuard" Rool"oard' in hot roofing asphalt "EnergyGuard'" Ultra" Is an acceptable altemate to "EnergyGuard" RF" in any applicable Classification. "GAF StraWvenft 61minabor+"" Venting Base Sheet (Nadlable)" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. "GAFGLASO Periite Ululation' may be utilized as a cover board over'EnergyGuard"4 RP insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or UL Classified urethane insulation adhesive. Polystyrene referenced in any of the following Classifications Include 'EnergyGuardTM EPS Insulation'. Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation Instructions (excluding LRF Adhesive O) in any applicable Non -Combustible Roof Deck Classifications. References tD glass fiber insulation Include "EnergyGuard Fiberglass Insulation". 'EnergyGuardTM Tapered' is an acceptable alternate to 'EnergyGuardT"" in any applicable Classification. ASPHALT FELT SrSTEItl4IIIIJITH NOT ROOFV4G ASPHALT Type 62 asphalt glass mat base sheet ('GAFGLAS® #75 Base Sheer or "Td-Ply® *75 Base Sheet', or "GAFGLAS® *80 ULTIMA") Is a suitable alternate for Type GI asphalt glass fiber ply sheet ('GAFGLAS® Ply r or'Td-Ply® Ply 40, or OGAFGLAS40 Ply 6") In the Class A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Sbatavent® Eliminatorm Venting Base Sheet (Perforated)" or "GAF Sbatavent® Eliminator" Verding Base Sheet (Nallable)." Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets arc to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet ('GAFGLAS® *75 Base Sheet' or'Tri-Ply® #75 Base Sheet' or'GAFGLAS® *80 ULTIMA' or "GAF Sbatavent@ E3iminatw4" Venting Base Sheet (Nailabie)' may be substituted for Type G1 asphalt glass fiber ply sheet ('GAFGLAS® Ply 4" or "T d-Ply® Ply 4' or "GAFGLASO Ply W) as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. "GAFGLASO Flashing' or'Rubemld®' may be used for flashing in any of the Class A, .B or C systems listed blow. When 'Perifte' Is referenced, this includes-GAFTEMP PERMALIiE®" or any other UL Classified perlite insulation Crushed stone or slag are suitable alternates for gravel in any of the Class A, 8 or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C- 15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of tie-in minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board betvaen minimum %-in. thick perlite board and deck with rosin paper (per lWrosin paper/polystyrene/perlibe) Is a suitable alternate for polyisocyanurabe board in the following Class A, 8 or C systems. hltpN/def ibansd.00nkgi-bikdXYVAwnpkiWLl3EXTHFRAMEbhw4xgeJtnl?name�--TGFUR14153&cc dwrOo=Racing Sysknudabdid=10l D7&d.. 1149 10118=6 TGFUR14153- Roo&V Systems pd�GrgyGuai�urate IWor t:sulatlon In any ored ff U �Ilowing Cla r xEr�o � uardm Composite RA' may be substituted for any Atlas Roofing Corp. Trumbull •Parma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLASO *80 Premium Base Sheet' may be used in any of the following systems. "GAFGLASe Rex Ply 6' and 'Trt-Ply® UAtra-Flodble Ply 6" are suitable alternates to "GAFGLASe ply 6". 'GAFTEMP Permalite Recover Board' may be used in lieu of any perilte insulation in any of the following NC Classifications. Unless otherwise indicated, any of the 'Asphalt Felt Systems with Hot Roofing Asphalt' may be surfaced with 'TOPCOATe Fireddeld MB" at: 2% to 3-gal/100-ft2. 'Ruberoid® Dual Smooth" may be used as an aitemnate to'Ruberdd® Mop Smooth" or'Rubemide 20" or "Ruberoide 20 HT". 'Ruberoide Mop Smooth LSO may be used as an altarru to to-Ruberoid® Mop Smooth'. . . Class A,"Y arid C : . • . ' • • • • • • •• • • organic and glass felts or modified bitumen membranes. • • • • • • • • Hot roofing asphalt, for use with o • • • • • • i � � • • • - "Ruberoide Heat Wad' SBS roofing membrane may be used In lieu of 'RuberoidO Mop" SBS products in aray WAAlcable 92assjfication.: "' • ; • • • • • / Indhm; 3 ..�.•� •••••: .•.••• 1. Deuk: C-15 32 Insulation (Opt ke Q, — One or more layers perlite or wood fiber or glass fiber or polylsocyanurAs & urethane, or perlite/polyisocyamn to composite or perlite/urethane composite or wood fiber/polylsocyanurate aynpos�0e or PlVdl� any thificness. P> Sheet: _ Three or more plies Type G1 or'GAFGLAS® Ply 4" or "Td-Ply® Ply 4" or "GAFGLAS® Illy 6' hot moped. • • • • •: Surfacing: • • • • . • • 2. Deck: C-15/32 Incline: 2 Insulation (Optional): — One or more layer; peliibe or wood fiber or glass fiber or polyisocyanurate or urethane or periite/polyisocyanurate composite or perilte/unethane composite or wood fiber/pdyisocyanurate composite or phenolic, any thldcness. Ply Sheet: — Three or more plies Type GI or "GAFGLASO Ply 4' or "Td-Ply® Ply 4- or "GAFGLAS® Ply 6. COP fit- — One ply Type G3 'GAFGLASO Mineral Surfaced Cap Sheer or'Tri-Ply® Mineral Surfaced Cap Sheet ` or'GAFGLASOD EnergyCapm SUR Mineral Surfaced Cap Sheet". 3. heck: NC : 2 Insulation (Optional): — One or more layers peritte, wood fiber, glass fiber, polyiso yan urate, urethane, pedite/polyisocyanurate composite, Perlite/uret ane composite, wood fiber/polyisocyanwrate composite, phenolic, 2-in. ma:dmum. PIy Sheet: — Two or more plies Type Gl "GAFGLASO Ply 4", 'Tri-Ply® Ply 4" or "GAFGLASO Ply 6". aP : — One ply Type G3-GAFGLASe Mineral Surfaced Cap Sheer or'Tri-Ply® Mineral Surfaced Cap Sheet' or "GAFGLASe Ener'gyCap"' BUR Mineral Surfaced Cap Sheet 4. • C-15/32 : 1 S1fp Sheet (Optional): — Red rosin paper, nailed to deck. Insulation (Optional): — Any thickness periite or wood fiber or glass fiber or polyiso yanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System' or any UL Classified Insulation adhesive. Base Sheet: — Qn . "•-�Qr e6,• ,� a cw.r+- or -Trl-Pry® #75 Base Sheet- (may be nailed). Ply Sheet: — OnLor more plies Type GI "GAFG 4" or "Td-Ply® Ply a or GAFGLAS®'PiV'S'---- dPfit: — Dim y y N Sufi Cap Sheer or'Tri-Plye Mineral Surfaced Cap Sheet' or "GAFGLASe EnergyCep"4 Burt Mineral SunaOel] Cap Sheet-. Surfacing (Optional): — "TOPCOAT® DargyCotel" Bastomedc Coating' applied at a rate of 2-W/100-ft2. S. Dedc: NC Incline: 3 Bate Sheet: — One ply Type G2 "GAFGLASe #75 Base Sheet" or 'Td-Plye #75 Base Sheet'. Ply Sheet: — One or more plies Type G1 *GAFGLASO Ply 4" or "Td-Ply® Ply 4' or-GAFGLASe Ply 6g. Cap Sheet: — One ply Type G3 "GAFGLASO Mineral Surfaced Cap Sheet" or'Td-Plye Mineral Surfaced Cap Sheet' or 'GAFGLASe &wrgyCa0— BUR Mineral Surfaced Cjp Sheet.' 6. Deck C--15/32 mediae: 2 Insulation: — One or more layers peeriite, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, perlite/urethane composite, phenolic, i in. minimum (offset a minimum of 6-in. from plywood deck joints). Base Sheet: — One or more plies Type G1 or Type G2 or Type G3. Membrane: — One or more plies "Ituberoide Torch Smooth" or "Ruberoide Torch Granule" or "Ruberold® Torch Granule Plus" or 'Ruberoide Mop Smooth" or "Ruberold® Mop Smooth 1.5' or "Ruberolde Mop Smooth Plus" or-Ruberolde Mop Granule" or "Ruberoide Mop Plus Granule" or "ROOFMatd 1 SBS Modified Granular' or'Trt-Plye SOS Modified Bitumen Membrane' or 'ROOFMatchTM APP Modified Granular" or'TH-Plye TP-4G" or "TH-Ply® TP-4" or "Ruberorde Dual Smooth'. Cap Sheet: — Type G3*GAFGLASO Mineral Surfaced Cap Sheet' or "Td-Ply® Mineral Surfaced Cap Sheeror "GAFGLAS® EnergyCap"" BUR Mineral Surfaced Cap Sheet' fully adhered with hot roofing asphalt 7. Deck: C-15/32 Iodine: 2 hdpJ/database d.-bINXWAempidM JSEXTIIFRAMEIalnwpage hlml?name=TGFUR141M&vnhorMer=Rod glt&J$WmAc bjid=10838 MDT&d .. 249 ROOFING SYSTEM APPROVAL Category Roofing Sub -Category: BUR Material: .Fiberglass Deck Type: Wood Maximum Design Pressure: -97.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions GAFGLAS® Ply 4 39.37" (1 meter) Wide Tri-Ply® Ply 4 39.37" (1 meter) Wide GAFGLAS® 39.37" (1 meter) F1exPly"- 6 Wide GAFGLAS®#75 39.37" (1 meter) Base Sheet Wide Tri-Ply8#75 Base 39.37" (1 meter) Sheet Wide GAFGLAS® #80 39.37" (1 meter) Ultima' Base Sheet Wide GAFGLAS® 39.37" (1 meter) Stratavene Wide Perforated Venting Base Sheet TABLE 1 Test Specification ASTM D2178 ASTM D2178 ASTM D2178 Prodwt: • • Descrit16b1r' • • Smooth surfaced asphaltic plysh`eet renfosoed with fiberglass mat. ..... • • • • • .• .. .. . Smooth surfaced asphaltiaply�9t�eet reinforced with fiberglass mat. • Smooth surfaced asphaltic IpV sleet r4nRkreed with fiberglass mat. • • • • ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced with fiberglass mat. ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced with fiberglass mat. ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced with fiberglass mat. ASTM D4897 Smooth surfaced asphaltic perforated venting base sheet reinforced with fiberglass mat. GAFGLAS® 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic nailable venting base Stratavent®Nailable Wide sheet reinforced with fiberglass mat. Bottom side Venting Base Sheet surfaced with granules. Ruberoid® 20 39.37" (1 meter) ASTM D6163 SBS polymer -modified asphalt base or Smooth Wide anchor sheet reinforced with a fiberglass mat. Ruberoie Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid® Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or anchor Smooth 1:5 wide sheet reinforced with a polyester mat. Ruberoid® Mop 39.37" (1 meter) ASTM D6164 Smooth surfaced mop applied SBS base or Plus Smooth wide anchor sheet reinforced with a polyester mat. Ruberoid® HW 25 39.37" (1 meter) ASTM D6163 Smooth surfaced torch applied SBS base or anchor Smooth wide sheet reinforced with a fiberglass mat. NOA No.:18-0919.07 zl► , Expiration Date: 11/04/23 APPROVED,Approval Date: 11/08/18 Page 2 of 27 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Teat Product Product Dimensions Specification Description Ruberoid® HW 39.37" (1 meter) ASTM D6164 Smooth surfaced torch applied SBS base or anchor Smooth wide sheet reinforced with a polyester mat. GAFGLAS® 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Mineral Surfaced Wide with fiberglass mat. ; • • • ; • Cap Sheet • 0 • • : • . . Tri-Ply® BUR 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltie capsheet reinforced • • • • • Granule Cap Sheet Wide with fiberglass mat. GAFGLAS® 39.3T' (1 meter) ASTM D3909 Granule surfaced asphaltic capsneet reinforced • •; • • • EnergyCap`" Wide with fiberglass mat. Cap 04&3 factarS I*Wed • • • Mineral Surfaced with TOPCOAT EnergyMe Elastomeric • • Cap Sheet Coating. ' . . . . ...... Topcoat® Surface 5 or 55 gallons ASTM D6083 •..•.• Solvent -based thermoplastic rubber ' • • Seal SB sealant designed to protect and restore;Wed'roof surfaces and to increase roof reflectivity. Topcoat® 1, 5 or 55 gallons ASTM D6083 Water -based elastomeric coating Membrane Topcoat® MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer designed to block asphalt bleed -through. Topcoat® FireOui' 5 or 55 gallons Proprietary Low VOC, water based fire barrier coating. Fire Barrier Coating VersaShiele Fire- 12" x 100' rolls ASTM D226 Non -asphaltic, fiberglass reinforced underlayment Resistant Roof and/or fire barrier Deck Protection VersaShieldo Solo"' 42" roll wide, 100 ASTM D146, Non -asphaltic, fire resistant fiberglass Fire -Resistant Slip & D828, 134869, underlayment Sheet D6757 Topcoat® 1, 5 gallons or TAS 139 FlexSeal'm 1 qt. tube APPROVED Solvent -based elastomeric sealant. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 3 of 27 APPROVED INSULATIONS: Product Name EnergyGuard' Polyiso Insulation EnergyGuard7" Tapered Polyiso Insulation EnergyGuard7' Ultra Polyiso Insulation EnergyGuard' RA Polyiso Insulation EnergyGuard" RA Composite Polyiso Insulation EnergyGuard' RH Polyiso Insulation EnergyGuard7 RH Tapered Polyiso Insulation EnergyGuard' RN Polyiso Insulation EnergyGuard'" Perlite Roof Insulation EnergyGuardm Perlite Recover Board TABLE 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Glass -faced polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation with high density fiberboard or permalite Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite insulation board Perlite recover board Securock® Gypsum -Fiber Roof Gypsum board Board Securockm Glass -Mat Roof Glass faced gypsum board Board Structodeltn High Density Fiber High density fiberboard Board Roof Insulation DensDecleo Prime Roof Board Gypsum board DensDeck® Roof Board Gypsum board APPROVED Manufacturer (With Current NOA) GAF GAF GAF GAF United States Gypsum Corp. United States Gypsum Corp. Blue Ridge Fiberboard, Inc. Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum LLC NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 4 of 27 APPROVED FASTENERS: Fastener Product Number Name 1. Drill -Tee'" #12 Fastener 2. Drill-Tec'" #14 Fastener 3. Drill-Tec— ASAP 3S 4. Drill -Teel" 3" Steel Plate 5. Drill-Tec"' 3" Standard Steel Plate 6. Drill -Tee"' AccuTrae Flat Plate 7. Drill-Tec'" AccuTrae Recessed Plate 8. Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) TABLE 3 Product Description Phillips head, modified buttress thread, pinch point, carbon steel fastener for use in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. Truss head, self -drilling, pinch point, high thread fastener for use in steel, wood or concrete decks. Drill-Tec"m #12 Fastener with Drill-Tec' 3" Standard Steel Plate. Round Galvalume® steel stress plate with reinforcing ribs and recessed for use with Drill-Tec' fasteners. Galvalume® coated steel stress plate for use with approved Drill-Tec' fasteners. A2-SS aluminized steel plate for use with Drill -Tee" fasteners. Galvalume® steel plate with recess for use with Drill- Tec"' fasteners. Round Galvalume® plated steel stress plate with reinforcing ribs for use with Drill-Tec'" fasteners. Dimensions #12 x 8" max. length, #3 Phillips head. Manufacturer (With Current NOM GAF #14x 16" •••••• max. length,. • .... #3 Phillips ..' ..' head •••••• See • components' 3" Round 3" Round 3" square; .01 T' thick 3" square; .017" thick 3" Round GAF GAF GAF GAF NOA No.: 1"919.07 NpgMw,aoe eat�rnY Expiration Date: 11/04/23 PR Approval Date: 11/08/18 Page 5 of 27 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Factory Mutual Research Corp. 3014547 4470 05/22/03 3029832 4470 05/11/07 3033135 4470 11/24/08 3034312 4470 04/09/09 3036980 4470 08/14/09 3038278 4470 ;...tV18/11 3040738 4470 .'. 11/16/1Q • •'; 3041769 4470 : • • 4Y26/1 t 3042887 4470 ...��• • . •„• . 3042905 •••; 4470 .11/14/11. 3046081 4470 •••••� �02�/13/13•;••• 3046388 4470 • • • • • • • •:D9J24/12.... 3047636 4470 "• " 0911/08/1-10 ODOA8.AM 4470 0.7/09/99 • ...... OD1A8.AM . 4470 . . ; • • MY29/94 OY9Q5.AM 4470 ' ..' 04/01/9E: 1B9A8.AM 4470 • • 09/04/97 2B8A4.AM 4470 07/02/97 3B9Q1.AM 4470 01/08/98 3D4Q2.AM 4470 05/30/97 797-03221-267 4470 09/27/07 797-03825-267 4470 07/21/08 797-10228-267 4470 01 /23/15 UL LLC R1306 UL 790 08/21/18 PRI Construction Materials GAF-122-02-01 TAS 139 05/07/06 Technologies, LLC GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-01Rev ASTM D6083 12/16/10 GAF-276-02-02 ASTM D226 11/15/10 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/ 11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-417-02-01 ASTM C1289 05/28/13 GAF-464-02-01 ASTM C1289 10/22/12 GAF-464-02-01 ASTM C1289 02/06/14 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-549-02-01 TAS 114 08/08/14 GAF-549-02-02 TAS 114 08/08/14 GAF-559-02-01 TAS 117(B) 09/30/14 GAF-559-02-04 ASTM D 1876 10/01/14 GAF-559-02-05 ASTM D 1876 10/15/14 GAF-559-02-06 TAS 114(H) 10/02/14 GAF-559-02-07 ASTM D 903 10/02/14 GAF-559-02-08 ASTM D 903 10/02/14 NOA No.:18-0919.07 APPROVED rtu►MFowne courmr Expiration Date: 11/04/23 Approval Date: 11/09/18 Page 6 of 27 EVIDENCE SUBM TTED: (CONTENUED) Test Agency Test Identifier Description Date PRI Construction Materials GAF-559-02-09 ASTM D 903 10/02/14 Technologies, LLC GAF-559-02-11 TAS 114 10/14/14 GAF-559-02-12 TAS 114 10/14/14 GAF-559-02-13 TAS 114 10/15/14 GAF-559-02-14 TAS 114 10/15/14 GAF-559-02-15 TAS 114 %JOW/14 GAF-559-02-16 TAS 114.0 .'. ' 10/15/14 GAF-559-02-18 TAS 114� : • 1845/14 GAF-559-02-19 TAS 114...:.. 04/16/15 GAF-628-02-01 ASTM C1289... -.05/31/16 IRT of S. Fl. 02-005 TAS 1140000,, � .Q1418/02 02-014 TAS 114..' ..' ' .03/2t/02 Testy ERD C8500SC.11.07 TAS 117; * * : *; 11/30/07 G30250.02.10-3-R2 ASTM D3969 % :'06/M/15 G31360.03.10 ASTM D6164. 03/3j/10 G33470.01.11 ASTM D6164 •??/16/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM' D6401 06/04/15 G34140.04.11-5-R3 ASTM D4897 06/04/15 G36780.07.11-R1 4470-TAS 114 07/18/11 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D6164 01/07/14 G40630.01.14-2A-1-R1 ASTM D6164 04/10/14 G43610.01.14 ASTM D3909 01/22/14 G6850.08.07-1 ASTM D3909 08/13/07 SC6870.08.14-R1 ASTM D3909 09/04/14 SC9700.08.15-R1 ASTM D2178 8/31/2015 SC10680.05.16 ASTM D6163 5/10/2016 SC13105.03.17-R1 ASTM D6164 3/23/2017 Dynatech Engineering Corporation #4482.02.95-1 TAS 114 09/01/95 Atlantic & Caribbean Roof 11-053 TAS 114 08/12/11 Consultants, LLC NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 7 of 27 APPROVED ASSEMBLIES Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(1): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. • • • • • • • Fire Barrier: . .. . . . . Topcoat® FireOut' Fire Barrier Coating, VersaShield* Fire-ResistVt hoof Decic•Protecttdff,• • . (optional) VersaShield* Solo' Fire -Resistant Slip Sheet, DensDeck®RoofBWd, Securock* Glass:....: Mat Roof Board or Securock® Gypsum Fiber Roof Board instalKmanuraotuisr's - • • **:*so installation instructions. •tv • Anchor sheet: GAFGLAS* #80 Ultima"' Base Sheet, GAFGLAS* Stratavent® f4glable Venting base • ; Sheet or Ruberoid* 20 Smooth mechanically fastened as descrip;+W. • • ; , Fastening ...... GAFGLAS* Ply 4, GAFGLAS* Flex Ply 6, GAFGLAS* #7512aso Sheet of any of abo ;e • • • Option #1: anchor sheets attached to deck with approved annular ring shank nails and tihAps'at a fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure -45 psf. See General Limitation #9) Fastening GAFGLAS* Ply 4, GAFGLAS* F1exPly 6, GAFGLAS* #75 Base Sheet or any of above Option #2: anchor sheets attached to deck with Drill-Tec' #12 Fastener, Drill-Tec' #14 Fastener and Drill-Tec' 3" Steel Plate, Drill-Tec' AccuTrac* Flat Plate or Drill-Tec' AccuTrac® Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45psf. See General Limitation #9) Fastening GAFGLAS® F1exPly 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of Option #3: above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure 52.5 psf. See General Limitation #7) Fastening Any of the above anchor sheets attached to deck with approved 1'/." annular ring shank nails Option #4: and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure -60 psf. See General Limitation #7) Fastening GAFGLAS* #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec' Option #5: #12 Fastener, Drill-Tec' #14 Fastener and Drill-Tec"' 3" Steel Plate, Drill-Tec'" AccuTrac* Flat Plate or Drill-Tec' AccuTrac* Recessed Plate 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf. See General Limitation #9) NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 9 of 27 Fastening (Continued) Any of above anchor sheets attached to deck approved annular ring shank nails and 3" Option #6: inverted Drill-Tec"' insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS' #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec' Option #7: #12 Fastener or Drill-Tec7" #14 Fastener and 3" Drill-Tec" 3" Steel Plate, Drill-Tec' AccuTrac' Flat Plate or Drill-Tec' AccuTrac' Recessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. ijg the Meld of the sheet. :0 0 0 9 0 (Maximum Design Pressure —45psf. See General Limitation #ijl.' : . . .' ...... .00060 • . •*0000 e or more layers of any of the following insulations. • off": •0000: Insulation Layer Insulation Fasteners • %�dristener .... . ..... Ene Guard'" Po „� (Table 3) f::: % -urps ity/ft! -: - - rgy Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation, EnergyGmaIA" Polyiso . 000000 Insulation, EnergyGuard"' RA Polyiso Insulation, EnergyGuard"' RA Composite Pol 64mulation • f Minimum 1" thick N/A 0 0 7y/A ...... EnergyGuard"' Perlite Recover Board, DensDeck' Prime Roof Board ' ' ' 0 0 Minimum 'A" thick N/A ' •' • N/A EnergyGuard' Perlite Roof Insulation Minimum %" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20401bsJ100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation panels may be used as a top layer placed with the polyisocyyanurate side facing down. GAF requires either a ply of GAFGLAS' Stratavene Perforated Venting Base Sheet laid dry or a layer of EnergyGuard' Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (Optional) Install one ply of GAFGLAS' #75 Base Sheet, Tri-Ply' #75 Base Sheet, GAFGLAS' #80 Ultima"' Base Sheet, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid' Mop Plus Smooth or Ruberoid' 20 Smooth, Ruberoid' HW Smooth or Ruberoid' HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. applied in accordance with manufacturer's instructions. (see General Limitation #4). OR GAFGLAS' Stratavent' Perforated Venting Base Sheet loose -laid dry (not for use with perlite top layer insulation or composite polyiso top layer insulation). Ply Sheet: One or more plies GAFGLAS' Ply 4, TriPly' Ply 4, GAFGLAS' FlexPly 6 or GAFGLAS' #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS' Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. installed per manufacturer's installation instructions. NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 9 of 27 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. ..... . 3. Fiber Aluminum Roof Coating. • Maximum Design ...... . ...... • Pressure: See Fastening Options. • • • • • • NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 10 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(2): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fiilly adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat' FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slili Sbat or (optional) VersaShield' Solo"' Fire -Resistant Slip Sheet installed per m;pV4( turerl installation •' � �' instructions. • • • • • • • Anchor sheet: GAFGLAS' #75 Base Sheet, Tri-Ply' #75 Base Sheet, Rubel AOM Smooth or :....: GAFGLAS' Stratavent' Venting Nailable Base Sheet is secmrp� j Mescrjk6elow. ; • • • • Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank' Hi'lil and nun, 1-S/8 in." Option #1: P diameter tin caps are aced 8 in. o.c. in the min. 4 in. wide • • * heet side la s and•§ • • • P spaced aPP P1 P • in. o.c. in the field of the sheet in two staggered rows. • • • • . . . . ...... (Maximum Design Pressure:-4Spsf. See General Lineitatien #7�1 Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank nails • and io, i.1518 in Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: -52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #3: AccuTrac' Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: 52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #4: AccuTrac' Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maadmum Design Pressure: -60 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #5: AccuTrac' Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: -75 psf. See General Limitation #7) One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe EnergyGuard"' Polyiso Insulation, EnergyGuard7 Tapered Polyiso Insulation, EnergyGuard"' Ultra Polyiso Insulation, EnergyGuard"' RH Polyiso Insulation, EnergyGuard' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 11 of 27 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ff EnergyGaard' Perlite Roof Insulation Minimum'/thick N/A N/A Structodek® High Density Fiberboard Roof Insulation Minimum'/? thick N/A N/A Securock® Gypsum -Fiber Roof Board, DensDecko Prime Roof Board Minimum'/4" thick N/A N/A Note: All insulation shall be adhered in a fall mopping of approved hot asphalt within the EVT eA*dand at a rate of 20-40 lbsJ100 fe. Please refer to Roofing Application Standard RAS 117 for ifljylation attachment. Base Sheet (Optional): GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, RubeMiiV120 Smdoth adhered hr • • a full mopping of hot asphalt applied at 20-40 lbsJsq. installed peere manufacturer's ... ,. installation instructions. • 00004 Ply Sheet: When optional base sheet and/or cap sheet is present: '"""• GAFGLAS® Ply 4, Tri Ply® Ply 4, GAt ® Fle) )sly b adhered Two or more plies of in a full mopping of hot asphalt applied at 20-40 lbs./sq. instilled I*r maqufaclurer's • • ;, installation instructions. • When optional base sheet and/or cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbsJsq. installed per manufacturer's installation instructions. Cap Sheet (Optional): GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbsJsq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 galJsq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 12 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(3): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Stilt �Pttor (optional) VersaShield® Solo'" Fire -Resistant Slip Sheet installed per m3nufdcturer's' installation• • • ° • • instructions. • • • • • • • 20 Smoothbr Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Rubetblda • 4, • ; GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured'a's.descrVed Below. ' • Fastening •Y•• • •• ..... Miami -Dade County Approved min. 12 ga. annular ring sham Udh:and 41e a l5/8 in. • • : • • • Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anc hbf sheet sigh laps and'8.4 : • in. o.c. in the field of the sheet in two staggered rows. 0 . . • . . ...... (Maximum Design Pressure. —45 psf. See General Limitation #7, " • • • • Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and A'a 5/8 in.' ' Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side Ups and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: 52.5 psf. See General Limitation #7) Fastening Drill-Tec"' #14 Fasteners and Drill-Tec7 3 in. Standard Steel Plates, Drill-Tec"' Option #3: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: 525 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #4: AccuTrac® Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maadmum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-Tec"' #14 Fasteners and Drill-Tec"' 3 in_ Standard Steel Plates, Drill-Tec"' Option #5: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —75 psf. See General Limitation #7) NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 13 of 27 One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe EnergyGuard7 Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation, EnergyGuard' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation, EnergyGuard' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Top Insulation Layer EnergyGuard' Perlite Roof Insulation Minimum 3/4" thick Stractodek' High Density Fiberboard Roof Insulation Minimum %" thick Insulation Fasteners Fastener (Table 3) Density/ftt N/A 14;A ...... .. . . . .' ...... ...... . ...... N/A •.•... I/A Securock' Gypsum -Fiber Roof Board, DensDeck' Prime Roof Board V. Minimum'/4" thick N/A •..&% ..�..' Note: All insulation shall be adhered in a full mopping of approved hot asphalt withiVd EVT rani a 0nd at'd rate of 20-40 lbsJ100 fe. Please refer to Roofing Application Standard RAS 117 for ipsu�a ffon ateac�ment. • • • • ...... Base Sheet: Ruberoid' 20 Smooth adhered in a full mopping of hot asphal� ap�ilied at20-401bs./s4..... Cap Sheet: GAFGLAS' Mineral Surfaced Cap Sheet, Tri-Ply* BUR Granule Cap Shea or • GAFGLAS' EnergyCar Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbsJsq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instractions. Ali coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bsJsq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbsJsq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 galJsq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.:18-0919.07 �flE eTM Expiration Date: 11/04/23 APPROVED Approval Date: 11/08/18 Page 14 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(4): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShield® Solo'" Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. :...:. 66664,9 Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid4b 20 Sm4 DAAr. • .... ,.. GAFGLAS® Stratavene Venting Nailable Base Sheet is secured:Wdescnlbed below. . . Fastening • ......... Miami Dade County Approved min. 12 ga. annular ring shank .nails.. and no. 1 -/8 in. • • Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anehw;heet side IA ps ands$• .... .• in. o.c. in the field of the sheet in two staggered rows. • • : " : . • • • (Maximum Design Pressure. -45 psf. See General Lin &atioa # Y. to. • Fastening Miami -Dade County Approved min. 12 ga. annular ring shank -nails And mint..1.44 in. • • Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anahosNeet si a las and Cti in. o.c. in the field of the sheet in two staggered rows. • .:.. to (Maximum Design Pressure. —52.5 psf. See General Limitation #7) Fastening Drill-Tec'" #14 Fasteners and Drill-Tec'" 3 in. Standard Steel Plates, Drill-Tec'" Option #3: AccuTraco Flat Plates or Drill-Tec"' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. 52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill -Tech' 3 in. Standard Steel Plates, Drill-Tec'" Option #4: AccuTrac® Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: -60 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Dfill-Tec` 3 in. Standard Steel Plates, Drill-Te6- Option #5: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —82.5 psf. See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 15 of 27 One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener Density/ft2 (Table 3) EnergyGuard'•' Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation, EnergyGuard' Ultra Polyiso Insulation, EnergyGuarC RH Polyiso Insulation, EnergyGuard" RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbsJ100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: GAFGLAS® Stratavene Perforated Venting Base Sheet is laid dry over the insulation. Ply Sheet: When optional cap sheet is present: Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAtS® F1e4PN Vadhered• • • in a full mopping of hot asphalt applied at 20-40 lbs./sq. instaldgdpet manufacturer's • Installation instructions. • • • • • • • • • • o • • When optional cap sheet is not present: • . • • Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFWAS® Flex.P•ly6 ..: • adhered in a full mopping of hot asphalt applied at 20-40 lbs./� Ulalled ��' • • • • • manufacturer's installation instructions. • Cap Sheet (Optional): GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Shet•Ot' • • GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet adhered jq; 4lu mopping of hot- • • • asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation inst+rnctions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 3001bsJsq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at I to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Marimum Design Pressure: See fastening options above. NOA No.:1"19.07 MwhtwYnt courmr Expiration Date: 11/04/23 Approval Date: 11/08/19 Page 16 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" thick or greater or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(S): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut' Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or VersaShield' (optional) Solo' Fire -Resistant Slip Sheet. Anchor sheet: GAFGLAS' #75 Base Sheet or Tri-Ply' #75 Base Sheet is secured as desonfiizd below.... o . with Dade County Approved nun. 12 ga. galvanized ring shanittmlt and ,1-5/8 in. • • ...... . ...... diameter tin tabs. • Fastening: Nails and tabs are spaced 8 in. o.c. in the 4 in. wide side lap add Sip. o.c.�n�two • "" staggered rows in the field of the sheet' " • • • • • ...... .... .... . One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners : : Faftener • (Table 3) : mAty/ft=. . EnergyGuard"' Polyiso Insulation, EnergyGnard"' Tapered Polyiso Insulation, EnergyGuard"' RH psWso :"": Insulation, EnergyGuardm RH Tapered Polyiso Insulation "" Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Structodek' High Density Fiberboard Roof Insulation, Securock' Gypsum -Fiber Roof Board Minimum %" thick N/A N/A Note: All insulation shall be adhered in a fall mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbsJ100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Ply: Two or more plies of GAFGLAS' FlexPly"` 6 adhered with hot asphalt applied at 20-25 1bsJsq. Cap Ply: GAFGLAS' Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 60 lbsJsq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat' MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 galJsq. Maximum Design Pressure: —525 psf. (See General Limitation #7) NOA No.:184919.07 MIAMFWIDEGOUN77 Expiration Date: 11/04/23 APPROVED I Approval Date: 11/08/18 Page 17 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type Q All layers of insulation are mechanically attached to roof deck Membrane k subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FkeOutd" Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or VersaShield' (optional) Solo"' Fire -Resistant Slip Sheet. :...:. ...... One or more layers of any of the following insulations. • • • • • • • � • • • • Base Insulation Layer (Optional) Insulation Fas enertsc Fastened ....: (Table 3)• • : • • ; • gensity/ft • • EnergyGuard' Polyiso Insulation, EnergyGuard' RA Polyiso Insulation, EnergyGuarj ;W PolyisAinsulathq . . • Minimum 1" thick N/A ..'..' N/A ...... Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. InsulaPon ' • panels listed are minimum sizes and dimensions; if larger panels are used, the numbez of fastenergMilA[ be • increased maintaining the same fastener density. Please refer to Roofing Application standard RAS.117 for insulation attachment. GAF requires either a ply of GAFGLAS' Stratavent' Perforated Venting N64heet laid dry or a layer of EnergyGuard' Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe SECUROCK' Gypsum -Fiber Roof Board Minimum %" thick 2,8 1:1.78 W Base Ply: Two or more plies of GAFGLAS® F1exP1yTM 6 adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions. Cap Ply: GAFGLAS' Mineral Surfaced Cap Sheet, Tn-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCe Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbsJsq. installed per manufacturer's installation instructions Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application Instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbsJsq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 601bsJsq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gaUsq. OR Topcoat' MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 galJsq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: -60 psf. (See General Limitation #7) NOA No.:18-0919.07 _:APPROVED' APPRO COUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 18 of 27 Membrane Type: Deck Type 1I: Deck Description: System Type D: BUR Wood, Insulated 19/32" or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. All insulation is loose laid with preliminary attachment to roof deck. Anchor sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Insulation Layer lation Fasteners Fastener (Table 3) �DeM#ity/ft2 EnergyGuard' Polyiso Insulation, EnergyGuard' Ultra Polyiso Insulation, EnergyGvard:'•RA Pblyi b' Insulation • • • Minimum 13" thick N/A "' : 00 N/A Structodek® High Density Fiber Board Minimum 1" thick . 0 0.0 . . ...00 .....0 ... ...0.' Note: Insulation shall have preliminary attachment, prior to the installation of the base. s get, at s lnia0 muln• • • application rate of two fasteners per board for insulation boards having no dimension gresber than 4A, and „ • four fasteners for any insulation board having no dimension greater than 9 & All layers or*nsulationo optioW. ,, thermal barrier (when present) and base sheet shall be simultaneously fastened. See pasg sheet below for • fasteners and density. Please refer to Roofing Application Standard RAS 117 for insulktiod atta*Vt tt. • .000 Fire Barrier: FireOuf- Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck Protection, (optional) VersaShield® Solo'" Fire -Resistant Slip Sheet, DensDeck® Roof Board, Securock'" Glass - Mat Roof Board or Securock"' Gypsum Fiber Roof Board N/A Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLASa #80 Ultimdw Base Sheet, GAFGLAS® Stratavene Nailable Venting Base Sheet or Ruberoid® 20 Smooth applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Fastening Drill-Tec"' #12 Fastener or Drill-Tece" #14 Fastener and Drill-Tec"' 3" Steel Plate, Drill - Option #1: Tec 3 in. Ribbed Galvalumie Plate (Flat), Drill -Teo"' AccuTrae Flat Plate or Drill-Tec"' AccuTrac® Recessed Plate is installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening Drill-Tec'" #12 Fastener or Drill -Tee #14 Fastener and Drill-Tec"' 3" Steel Plate, Drill - Option #2: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill-Tece' AccuTrac® Flat Plate or Drill-Tece' AccuTrac® Recessed Plate is installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf. See General Limitation #9) Fastening GAFGLAS® #80 Ultima"' Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth Option #3: attached to deck with approved annular ring shank nails with a minimum embedment of 1" into the wood substrate and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) NOA No.:184919.07 rnnMFannEcour�n Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 19 of 27 Fastening (Continued) Drill -Tee #12 Fastener or Drill -Tee #14 Fastener and Drill -Tee 3" Steel Plate, Drill - Option #4: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill -Tee AccuTrac* Flat Plate or Drill-Tec"" AccuTrac* Recessed Plate in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf. See General Limitation #9) Ply Sheet: One or more plies of GAFGLAS* Ply 4, Tri-Ply® Ply 4, GAFGLAS* F1exPly 6 or GAFGLAS* #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS* Mineral Surfaced Cap Sheet, Tri-Ply BUR Granule Cap Sheet or GAFGLAS* EnergyCap"' Mineral Surfaced Cap Sheet 4dherectra fell mopping of approved asphalt applied within the EVT range and'at a race of 20-401bs./sq. . • installed per manufacturer's installation instructions. • • • ; • • • • • • • • Surfacing: Optional on granular surfaced membranes; required for smooth inembrAnm Chos4d • • •; components must be applied according to manufacturer's appliadon instruadons...... All coatings must be listed within a current NOA. • • • • • • • • • • • • • • • .. .. .. . ...... 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respective loo in a - flood coat of • approved asphalt at 601bsJsq. • • • • • • 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 fa i'S V./sq. .. ;' • • • OR 0000 Topcoat° MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat* Membrane applied at 0.5 to 0.75 galJsq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.:18-0919.07 MTT-I oNwE eotmrr Expiration Date: 11/04/23 ROVED I Approval Date: 11/08/18 Page 20 of 27 Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(1): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat' FireOut"' Fire Barrier Coating, VersaShield' Fire Resistant Roof Deck (optional) Protection, VersaShield' Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. :... ; . Base sheet: ...... GAFGLAS' #80 Ultima' Base Sheet, Stratavent® Nailable Venting Base Sheet, Ruberoid' . 20 Smooth, Ruberoid' SBS Heat -Weld' Smooth or Ruberoid' SB3 Heat-Rltld 25 base .... • sheet mechanically fastened to deck as described below; Fastening ..... .. . . . GAFGLAS' Flex Ply 6, GAFGLAS' #75 Base Sheet, Tri-Ply&W" Base gheetoi any of • • Option #1: the above anchor sheets attached to deck with approved annulaf fibrdiank U&IC 0gd tin " • • • caps at a fastener spacing of 9 o.c. at the 4 lap staggered and *n twor rows 9 o.c. m the . field. • . . . . ...... (Maximum Design Pressure —52.5 psf. See General Limiodom #7). : ""' • Fastening ...... GAFGLAS' #80 Ultima' Base Sheet, Ruberoid' 20 Smooth or Ruberoid' Mops $month* ' Option #2: attached to deck with approved 1'/4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure —60 psf. See General Limitation #7) Ply Sheet: One or more plies of GAFGLAS' Ply 4, Tri Ply' Ply 4 or GAFGLAS' #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bsJsq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS' Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCar Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the -EVT range and at a rate of 20-401bs./sq. installed per manufacturer's installation instructions. Surfacing. Optional on granular surfaced membranes; required for smooth membranes. Chosen components most be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbsJsq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gaiJsq. OR Topcoat' MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 galJsq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/09/18 Page 21 of 27 Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(2): Anchor sheet mechanically attached to roof deck. All General and System Limitations sball apply. Fire Barrier: Topcoat' FireOui ' Fire Barrier Coating, VersaShield' Fire Resistant Roof Deck (optional) Protection, VersaShield' Solo"' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. • Anchor sheet: GAFGLAS' #80 Ultima Base Sheet mechanically attached witliMilk-Dade County .' '/sps • • • • : • Approved min. 1long, 12 ga., annular ring shank nails and 1-50;diumeter tin ca spaced T' o.c. in the min 4" wide side laps and in 3 staggered ro**§ 1d the field df the she l.• • • ; Ply Sheet: Two or more plies of GAFGLAS' Ply 4, Tri-Ply' Ply 4, GAFGL*80 VlexPV 64dhered to - • • the base sheet in full mopping of approved asphalt applied withM Me EVT rphA0tpd at a • % • rate of 2040 lbs./sq. installed per manufacturer's installation iAt clions. "";' Cap Sheet: One ply of GAFGLASO Mineral Surfaced Cap Sheet, Tri-PlyV BUR•Granglp•Q4U Sheet or-: • GAFGLAS® EnergyCaprM Mineral Surfaced Cap Sheet adherod m mull mbpping of :.... ; approved asphalt applied within the EVT range and at a rate of 20•-401bs./sq.•instailed per ' manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bsJsq. and 3001bsJsq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat' MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 galJsq. Maximum Design Pressure: -92.5 psf. (See General Limitation #7) NOA No.: 18-0919.07 MIAMFOADE COUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 22 of 27 Membrane Type: BUR Deck Type 1I: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(4): Anchor sheet mechanically attached to roof deck All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOui ' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet (optional) VersaShield® Solo' Fire -Resistant Slip Sheet, installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth of M iGLAS® .... Stratavent® Venting Nailable Base Sheet is secured as described below' : . . .' FasteningMiami-Dade County Approved min. 12 annular ring shank nails �Q�in. 1 S/8 ' diam ter ' : ' ty PP Sa• g ln• q Option #1: tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet sidelaps and 8 in o.c. in the"": field of the sheet in two staggered rows. .... . .. ..... (Maximum Design Pressure. —45 psf. See General Limitation #7l .. " • • • • • • • • • • Fastening . .. .. . ...... Miami -Dade County Approved min. 12 ga. annular ring shank nail.axd�in. 1-5/8 in. diameter.' Option #2: tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 ip. p q. jn the- • • • • field of the sheet in two staggered rows. • . . .. 0 ...... (Maximum Design Pressure: 52.5 psf. See General Limitation Fastening Drill-Tec' #14 Fasteners and Drill-Tec"' 3 in. Standard Steel Plates, Drill-Tec' AccuTrac® Option #3: Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. 52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-Tec' AccuTrac® Option #4: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec"' AccuTrac® Option #5: Flat Plates or Drill-Te6' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure. —97.5 psf. See General Limitation #7) Base Sheet: Ruberoid® 20 Smooth adhered in a full mopping of hot asphalt applied at 20-401bs./sq. installed per manufacturer's installation instructions. Cap Sheet: GAFGLAS* Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCar Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. NOA No.: 18-0919.07 Expiradon Date: 11/04/23 Approval Date: 11/08/18 Page 25 of 27 Surfacing: 1. 2. 3. Optional on granular surfaced membranes; required for smooth membranes. Chosen components most be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. Gravel or slag applied at 400 lbsJsq. and 3001bsJsq. respectively in a flood coat of approved asphalt at 601bs./sq. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. Aluminum Fiber Roof Cnatinw_ :...:. Maximum Design Pressure: See Fastening Above. ...... . ...... .... . .. ..... ...... .... ..... .. .. .. . ...... . . . . ...... NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 26 of 27 MMAM MIAM1-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMDUSTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.P_ov/economy Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: .""" .. ...... This NOA is being issued under the applicable rules and regulations governing the use of cot;$.u.c.tion m. aterials. The • documentation submitted has been reviewed and accepted by Miami -Dade County RER -P�pA2ot Controi Sea Lion toVer used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdi&tdtl (AHJr • • ..... ...... .... .... ... This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count5ofpoduct Control $ectiou .... (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve:he:i ht to have this • • product or material tested for quality assurance purposes. If this product or material fails to perfoim in U.4Upted 0 • . •' • manner, the manufacturer will incur the expense of such testing and the AHJ may immediately %yoke, modify, or .... suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke ail ppceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Medium Profile Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.17-0822.14 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino a NOA No.18-0509.19 Expiration Date: 10/05/21 Approval Date: 06/14/18 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category Sub Category Material: 1. SCOPE: Roofing Roofing Tiles Concrete This approves a system using Eagle Roofing Products Medium Profile Concrete Tile, as•manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Sjctign.2 of this Yofice of• • • • Acceptance. For use in locations where the pressure requirements, as determin✓sd b)r appliO4blg$uilding • Code, do not exceed the design pressure values obtained by calculations in coUpoliance with RAS 127" using the values listed in section 4 herein. The attachment calculations shallbey, Oppe as a }Vongpnt basfd • • • system. •••• • •• ••••• • • •••••• •••• ••••• 2. PRODUCT DESCRIPTION: •' • • • • • • Manufactured by Test Producti ...... Applicant Dimensions Specifications Destrindw • Medium Profile Concrete Lenght = 17" TAS 112 Low profile, interlocking, high pres%M gxtruded • Tile Width = 12 %" Type 1 b concrete roof tile equipped with three nail hole Thickness='/2" Class III and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Trim Pieces Lenght = varies TAS 112 Accessory trim, concrete roof pieces for use at Width = varies hips, rakes and ridges. Manufactured for each tile varying thickness profile. 2.1 EVIDENCE SUBMITTED: Test Aaency Test Identifier Test Name/Reyort Date PRI Construction ERPF-001-02-02 TAS 112 Aug. 2006 Materials Technologies Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied 94-060B Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) NOA No. 18-0509.19 Expiration Date: 10/05/21 Approval Date: 06/14/18 Page 2 of 7 Redland Technologies Professional Service Industries, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. APPRO'1ED Letter Dated Aug. Wind Tunnel Testing 1, 1994 TAS 108 (Nail -On) 22447099 Physical Properties TAS 112 25-7094-1 Static Uplift Testing TAS 102 (4" Headlap, Nails, Direct Deck, New Construction) 25-7094-7 Static Uplift Testing TAS 102 (4" Headlap, Nails, Battens) 25-7094-4 Static Uplift Testing TAS 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Project No. 307025 Wind Driven Rain Test #MDC-76 TAS 100 25-7183-1 Static Uplift Testing TAS 102 (2 Quik-Drive Screws, Direct Deck) 25-7183-2 Static Uplift Testing TAS 102 (2 Quik-Drive Screws, Battens) 25-7214-2 Static Uplift Testing 25-7214-6 TAS 102 (1 Quik-Drive Screw, Direct Deck) (1 Quik Drive Screw, Battens) 528454-2-1 Static Uplift Testing 520109-2 TAS 101 Evaluation Two Patty Adhesive Set System Calculations Evaluation 25-7183 Calculations Evaluation 25-7094 Calculations Evaluation 25-7496 Calculations Evaluation 25-7584 Calculations 25-7804b-8 25-7804-4 & 5 25-7848-6 Calculations Aerodynamic Multiplier Calculations Restoring Moment Due to Gravity Aug. 1994 Sept. 1994 Oct. 1994 Oct. 1994. ......Oct. 1994 . . ...... .... . . . ......Oct. 1994 . . . ...... • • • • ; Feb. ) 99�. . Feb. 1995 March, 1995 Sep. 1998 Dec. 1998 April 1999 March 1995 February 1996 April 1996 December 1996 Sep. 2006 Sep. 2006 NOA No.18-0509.19 Expiration Date: 10/05/21 Approval Date: 06/14/18 Page 3 of 7 ATL of South Florida ATL of South Florida PRI Construction materials Technologies 3. LIMITATIONS: RT1211.03-15 RT0706.02-17 DAPF-001-02-04 DAPF-003-02-01 DAPF-003-02-03 TAS 112 TAS 112 TAS 101 (2 PD ) TAS 101 (LRG) TAS 101 (MED) 12/17/15 09/25/17 11/30/17 04/06/18 04/06/18 3.1 Fire classification is not part of this acceptance. ...... : ""' ....:. 3.2 For mortar or adhesive set file applications, a static field uplift test in accordance with4AS 106 shall be ; • • • • required, refer to applicable Building Code. • • • • • • • • 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to OCHVIn quarte�ry test ins • accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Mid JXde C81.Tty 3'rodurg .... Control Section for review. • 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applioati4n9 Stances $fisted • • • • • section 4.1 herein. • 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the ioof slope &Ie� 'stated' otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable Building Code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC, Medium Profile Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-1 (ft) Width-w (ft) Medium Profile Concrete Tile 9.5 1.417 1.04 Table 2: rodynamic Multipliers - ft3 Tile Profile A, (ft3) Batten Application A. (ft3) Direct Deck Application Medium Profile Concrete Tile 0.305 0.282 Table 3: Restoring Moments due to Gravi - M ft-lb Tile Profile 3":12" 4":12" 5":12" 6":12" 7":12" or greater Medium Profile Concrete Tile Battens Direct Deck Battens Direct Deck 1 Battens Direct Deck Battens Direct I Deck Battens Direct Deck 6.30 6.65 6.21 6.54 6.08 1 6.41 5.93 6.25 5.77 6.08 NOA No. 18-0509.19 Expiration Date: 10/05/21 Approval Date: 06/14/18 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" plywood) (min. 19/32" plywood) Medium Profile 2-10d Ring Shank Nails 27.8 37.4 28.8 Concrete Tile 1-10d Smooth or Screw 8.8 11.8 4.1 Shank Nail 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails • 1 #8 Screw 25.8 25.8 .9 ... 2 #8 Screw 47.1 47.1 .. 49.1 1-10d Smooth or Screw 24.3 24.3 ...... .2 ... Shank Nail Field Clip) ...:.. th or ew 19.0 19.0 Shank Nail Eav Cl 0••••� �•• * .••I 2-10d Smooth or Screw 35.5 35.5 • • • • • • .. :n8 • • •' Shank Nails Field Clip) • • • • • • • • • • 2-10d Smooth or Screw 31.9 31.9 :":': 432.2 Shank Nails Eave Clip)• • •' • • • • • • 2-10d Ring Shank Nails' 43.0 67.5 .. .9 1 Installation with a 4- the headlap and fasteners are located a min. of 2'/s'from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Medium Profile Concrete Tile Adhesive2 2 See manufactures component approval for installation requirements. 3 The Dow Chemical Company TIIeBond Average weight per paddy 11.4 grams. 26.1 4 ICP Adhesive Po et ® AH-160. Average weight per patty 8 grams. 26.1 5 DAP Foam Touch N Seal StormBond 2 Roof Tile Adhesive. Average weight per paddy 8 grams. 101 Table 6: Attachment Resistance Expressed as a Moment - K (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Medium Profile Concrete Tile Adhesive2 2 See manufactures component approval for installation requirements. 3 Large paddy placement of 54grams of ICP Adhesives Polyset® AH-160. 86.61 4 Medium paddy placement of 24grams of ICP Adhesives Polysem AH-160. 45.5 5 Medium paddy placement of 26.6 rams of DAP Foam Touch N Seal StormBond 2 Roof Tile Adhesive 54 6 Large paddy placement of 55.5 rams of DAP Foam Touch N Seal StormBond 2 Roof Tile Adhesive 61 NOA No. 18-0509.19 Expiration Date: 10/05/21 Approval Date: 06/14/18 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set S stems Tile Profile Tile Application Attachment Resistance Medium Profile Concrete Tile Mortar Set' 20.60 1 Tile-Tite Roof Tile Mortar. $. LABELING . • • • • • • • • All tiles shall bear the imprint or identifiable marking of the manufacturees ume or 1pgo(,See Detail Below), or following statement: "Miami -Dade County Product ControfAplxoved".: • •. • ...... .... EAliGiLE FL ORIDA (LOCATED ON UNDERSIDE OF TILE) OR EAGLE FL (LOCATED ON FRONTSIDE OF TILE) MEDIUM PROFILE CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT .0000 ••••• ••••• • • • • • . .0000 .0000 NOA No.18-0509.19 Expiration Date: 10/05/21 Approval Date: 06/14/18 Page 6 of 7 6. BUILDING PERNIIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the installation of this system. PROFILE DRAWING MrL HOLE I MEDIUM PROFILE CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.18-0509.19 Expiration Date: 10/05/21 Approval Date: 06/14/18 Page 7 of 7 MIAMI-DADE COUNTY MT® PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidadl.gov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: •••••• This NOA is being issued under the applicable rules and regulations governing the use of tbnsttuctioD.Wterials. The. documentation submitted has been reviewed and accepted by Miami -Dade County RER -I'rMI Control Section t8b't"' used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction ZAHJ). :. •..: This NOA shall not be valid after the expiration date stated below. The Miami -Dade CourWProduct'Cof1frol Sect?w • • (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve th@ right to hav%4his proddef or material tested for quality assurance purposes. If this product or material fails to perform 'n & accepted manner, tt► @ • manufacturer will incur the expense of such testing and the AHJ may immediately revoki modtfy, or.susp;nd the.i1se•;. of such product or material within their jurisdiction. RER reserves the right to revoke this acdPtdWdb, if 4 is determined by Miami -Dade County Product Control Section that this product or material fails tomeet she loquiremefs n of the applicable building code. • • • • This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset' AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. Vic' NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Rop f= Application Standard RAS 127. For use with approved flat, low, and high profile roof tile yystg ft using ICP • • • • • • Adhesives Polyset® AH-160. Y....J ...... . ...... PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product13escription Specifications r.. .• . w ... ICP Adhesives N/A Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPacV N/A 30 & 100 TAS 101 Two component p4ly"hane foam adhesive- • Dispensing Equipm;rA... Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Pro a Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -400 F., 2 weeks +6.0% Volume Change @158'F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MIAMMADE COUNTY lnvj Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test AQencv Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 ••...• Miles Laboratories NB-589-631 ASTM D 1623 • •; ,02/01/94 • • Polymers Division ...... : • • •' • ...... Ramtech Laboratories, Inc. 9637-92 ASTM E 108 --04�/36/93 • • �: .... . .. ..... Southwest Research Institute 01-6743-011 ASTM E 108 ":": .1'1`/=604 ' • • • • • 01-6739-062b[ 1 ] ASTM E 84 dP/ 16795 **so:* . . Trinity Engineering 7050.02.96-1 TAS 114 . • � P36700.04.12 ASTM D 1623 '..' .04/18/12 P39740.02.12 TAS 101 %144712 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with:thease of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or e�geej the resistance value determined in compliance with Miami -Dade County Roofing Application Standards P." 127. Tlradhesive .... ; attachment data is noted in the roof tile assembly NOA. • • • : • • 0 • 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance m %oofinj Npp'licatiod Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and.l WVtrenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed43PICP Adefives and ...... Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applic4bf4fdthe authotity having •, . . . . ...... jurisdiction. • • • • • 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before applicatilh of any adhesive. The mix ratio between the "A" component and the "B" component shall be mainta;mtl between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches A5-65 Profiles ...... Flat, Low, High Profiles # 1 17-23 sq. inches •45-66 . Flat Profile #2 10-12 sq. inches • • • • 30 Low Profile #2 12-14 sq. inches .. •030. High Profile #2 17-19 sq. inches „� Q, Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches It' • • 12 grarAr per paddy • • head of tile 9-11 sq. inches a%' :': • overlap •.... Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal ' ' 17 gra'per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 :. ADHESIVE PLACEMENT DETAIL # I ft0throughplastke4owd Raddyleeneathli.j (wti.e Pequlredi Undv&yment ° i Ban"" 00" ° E.wf.mne loin. .sca Emso Cloum Neil through plastic cement (when required) (Paddy libn■•th Tael my ed t 1 e�,kr 10 In, 21n_wl0e 'Meng optional Z tot.. � ��. ✓ Emote Closure caveCourse Fascia 11.E theugb plMrsle cm (when requdradF kiddy IA+oa.ehTilrl Uhdlrrl.yment ° 3 t01n.k 2 In. made (amns optional ° Eave ceutse Fasda IF Weephole Win. 1n. EeR clo sure Orlp edge APPROVED Flat/Low Profile Tile l . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned aS shown, under the strengthening:ribclasest tb the overlodV • • • • of the tile being set. • • • . • • ...... . ...... 2. Continue in same manner. insure approximately;P? • • (109.7 cm2) — 23 (148.4 e1�4 square it" Adhesive... contact with the undersidq oflhe tilg! • • • • • • • . .. .. .. . ...... . . . . ...... ...... • • . Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Md1 though Pia+ak tlmsms Md1dy lilrmeathtirl twhan required) UndarlaywArA • �y`'� 2in. Battens optional ' Eaw{oursr o101 • Fasda �211h Earatlowre,�t � Nail through plastic cement When Fequiredl Paddy illenaath TIla3 Underlay "I 71n. In. Battero optional ,-�~'4 10 tay,Clr.uo. Far■ Csursr Fascia Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1 " (25.4 mm) foam paddy onto the underlayment positioned as slV" tmder tt% • • • • strengthening rib of the til'edasdst to tUe overlock of . • the tile being set. Insure apppopixiatel}i t7 1169.7 ciin, ). % — 23 (148.4 cm2) square i11 adhesive contact with -the • ...... underside of the tile. . "' •. ; • * • • • .... . .. ..... . • 2. At the second course, appV. as *'imuln t0.8 : t5mmj a " x 7" (177.8 mm) x 1" (25.1.Wal foam as onto the � 0 underlayment positioned 3s slto` rn under the 0 0 • strengthening rib closest to the•overloX8rMe tile . . being set. • • • • • ...... ... 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12(77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1 " (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) NO t"ulh plastic c• (wh•n requlmd) R■ddy 19•n•us6 Til■f 21ti out•nsaptlowal Fa eGoM,se asm W■.ph■M loin, z N. Low des"M Qtlp edge High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) fbam$addy onto the underlayment poSgg09ae j as shown under t$e pan portion of the tile closCittAthe ovoeek i f the • tile being set. Insure approx4mi tgly 17 (109.7 cm2) .— • 23 (148.4 cm) square inch adhesive contactwith the underside of the tile. • • • • • • 0 00000 ...... .... ..... At the second course, appy a minimumT (S0.8mrhj •'; • ••■■■ x 7" (177.8 mm) x 1" (25$ mtntfoam jpad'dy onto the '. ...... underlayment positioned as shown un(Imethepan • portion of the tile closest to.th'e dverlork ofjhe tile; • • • •; being set. 0 a ' 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 flail through plastic ceman paddy (between ties) (when regoiredl Battens optional ° • Paddy tender tile) Sine Ply on top of tie ,r tx4in. undertil Single paddy ,�`•-= on undetlaynxrK 2 z 4 in toin lin Rm uosve Flat/Low Prome The Hai through plastic cement Single paddy under tie (when required) paddy (between des) Battens Paddy under tie) opdanaI on clop :din. ~ x �q{� 41n.`• urm*pa�- y+nnK -, o in. 2 in. Ears Closure Eave Coarse Fascia Medium ProflleTlle 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1 " (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or taft he pan portion of the tile for lo%v of high prdfile tile closes? •; • to the overlock of the the 6eiek set. L_"v;. approximately 4" (101.¢ up from the eave edge free of foam to prexma the expVde� adhes'ira • • from blocking the weep lao"' Insule'.. • 00000 approximately 17-23 in;(jWP7-148.4em2� of ..:..' adhesive contact with the imtlersidelokLe•tile • • •... . . . . ..... . 2. Apply a 4" (101.6 mm� 4+'o`401.6 1nm)x 1" (2SA.. mm) foam paddy onto the underlays jest below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in (51.6-58.1 cm) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nap through plastic Single paddy uder tpe (when required) Paddy (between dies) Battens optional �-% Paddy(undertne) �onwt�derh 4 z 4 in. pa on.� top,itie FaveCa rse ' 1 Fasda Weephole 10 in? in. Eve dbsurc Drip edge High ProflleTlle MIAMI•DADE COUNTY 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the streWheping rib for flat tile or on top of -the pan portal bf the tile,..... closest to the underlock of tha first course of tile. .' •••.•.. . Install second course of titP.ftsure tlpproximatei5o • • • • 9 (58.1 cm) - 11 (71enl�* glbre inch adhesive r.•.�; contact with the underside otthe tiloo'at tRs overlap and 7 (45.2 cmz) - 9 (5$,lxj�;�) square�n� h •. • adhesive contact with tjwlrside'QZlhgtile at*,:: " : the head of the tile. Contisive4n same manner. . • •• • • •• • . •••• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications In contact with the pan tile. A (when required) 2) Turn covers upside down. Place adhesive In to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25sq. In. contact area. IUnderlayment o Eave closure (motar shown) Fascia Rtmove top portion of the taw course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (25,t mrpj jx 1" (Y.4 mm) foam* paddy onto the underl&jlineAt poslif"as • • shown under two adjacent• an tiles. Support eldd • • • •, • • • • tiles from rocking until esive has a chance la a • • cure. 00000 0 • • • ••t••• •••• •t••t 2. Continue in same manner bringing avo ;an assess courses up toward the 1*1M Insure • l approximately 65 (4 M.4 crf12) — 7LQM6 cm4)• • • • • square inch adhesive:contaat withthe undersiijq.• of the pan tile. • • •••• Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11