Loading...
RF-19-2765Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 01/13/2020 Location Address Parcel Number 1411 NE 102ND ST, Miami Shores, FL 33138 1132050240200 Contacts Permit No.: RF-1 1 -19-2765 Permit Type: Roof Work Classification: Tile Permit Status: Approved Expiration: 07/13/2020 ROGERIO AND MIGDALIA CARRILLO Owner DM ROOFING COPMANY INC Contractor 1411 NW 102 ST, MIAMI SHORES, FL 331382621 DENIS MARTINEZ Other: 3057547185 1951 NW 141, OPALOCKA, FL 33051 Business: 3056847587 DMROOFINGCO@GMAIL.COM Mobile: 7862673066 Description: TILE RE ROOF Valuation: $ 30,200Inspection Requests: 305-762-4949 Total Sq Feet: 3,266.00 Fees Amount Application Fee - Other $50.00 CCF $18.60 DBPR Fee $4.88 DCA Fee $3.25 Education Surcharge $6.20 Roofing Fee $275.00 Scanning Fee $9.00 Technology Fee $8.13 Tota I : $375.06 Payments Date Paid Amt Paid Total Fees $375.06 Check # 3803 11/19/2019 $50.00 Check # 3885 01/13/2020 $325.06 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor do the work stated. 1 n Authorized Signature: Owner / Applicant / Contractor / A6ent Date January 13, 2020 Page 2 of 2 Miami Shores Village FZ'F,-C Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC I< ROOFING \NOV19�19 BY: FBC 20 Master Permit No. I I — C, ► l7 J Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: `A\\ City: `Miamii Shores /� I� County: Miami Dade Zip: L 8165 1 `' Folio/Parcel#: J 2 !i • UZ - VZw_Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BF((E::FFE: OWNER: Name (Fee Simple Titleholder): ,� Phone#: " 1,,�� L\t6$ __!1 61 AddressAL4\ � �. loz�' 4 City: In%c \ 5mre-s T State: k)Ic (` Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Mn YcUNl Address: y City: �~ r(a State: Zip: Qualifier Name: __ `-� Phone#: �,��'".e State Certification or Registration #: 11�"t1 Certificate of Competency #: DESIGNER: Architect/Engineer: Address: City: Phone#: Zip: Value of Work for this Permit: $ 30. %7 .(Do Square/Linear Footage of Work:1,�C� Type of Work: ❑ Addition ❑ Alteration �ltera�QY�tion❑ New ❑ Repair/Replace �1 ❑ Demolition Description of Work: ���� �` le - E. Specify color of color thru tile: Submittal Fee $ �d Q 1 Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF $, DBPR $ CO/CC $ Notary $ Double Femme !$ Bond $ TOTAL FEE NOW DUE $ ' Uk�' (Revised02/24/2014) �� /, Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip ►9 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. 1 /OWIJE? or 4GE1JT The foregoing instrument was acknowledged before me this — ;-14— day of 20 , by who is ersonal y < n to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: ALVAREZ Print: CONTRACTOR The foregoing instrument was acknowledged before me this Z4+"day of fbC'jo20 J by 1 � n �ii b , who is ersonally know to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign:_ Print: Commission # GG 15801 Seal: 9F off; My Commission Expires Seal: July 26, 202C I � APPROVED BY r Plans Examiner Structural Review ISAAMANDA FERNANRE� State of Florida -Notary Publi _+ •; Commission 0 QO 218888 My Commission Expires May 18, 2022 Zoning Clerk (Revised02/24/2014) PH: 305-684-7587 EMAIL: DMROOF INGCO@GMAIL.COM WEBSITE: WWW.DMROOFINGCO.COM REROOF & REPAIRS RESIDENTIAL & COMMERCIAL PROPOSAL SUBMITTED TO: E% ROOFING CO. LICENSED & INSURED CCC1331191 PROPOSAL TILE SHINGLE FLAT ROOF METAL ROOF ROOF MAINTENANCE DATE: OCTOBER 29,2019 NAME/S: Ro erio & Mi dalia Carrillo l JOB NAME: Carrillo Residence STREET: 1411 N.E. 102nd Street PHONE: CITY: Miami Shores ALT PHONE: STATE: FLORIDA zIP: 733138 EMAIL: DM hoofing Company Inc. will furnish all materials and perform all labor necessary including hauling all roofing debris to complete the following; TILE REROOF - PEEL AND STICK: 1. All labor and materials to remove the existing roof down to the sheathing boards. 2. Replacement of any rotten or decayed lumber is as follows, first 1001in./sq ft. included, after that cost is $3.50 per lin /sq ft. 3. Re -nail deck with 8d ring shank nails. 4. Over the entire roof apply 1430 ASTM felt, tin capped according to code. S. Install all new 3x3 eave drip around the perimeter of the house, new lead flashings for the plumbing pipes, and new 16" wide galvanize valley metal in all valleys. 6. To install all new J vents and AP vents as needed. 7. Apply a Polystick T/U peel & stick over entire roof according to code. 8. To install all new ridge metal for tile and metal bird stop. 9. Over the entire roof apply a new tile, set in a paddy of foam, and cement all ridges. 10. Premises are to be left in a clean condition free from all roofing trash and debris. 11. Upon completion and final payment this roof will carry a 10 year guarantee on all workmanship. 12. All permits including uplift and engineering reports included in contract price. 13. All work to be done according to the Florida Building Code. NOTE: PAYMENTS CANNOT BE WITHHELD AS A RESULT OF ADDITIONAL WORK THAT IS REQUESTED BY HOMEOWNER AFTER JOB COMPLETION. All of the above work is to be completed for the sum of. Thirty-two thousand two hundred dollars $32,200.00 Payment Terms: 50% Down 30% Upon Dry -in 20% Upon Completion 2 n NOTICE TO OWNER This offer price is only valid 30 days and is void thereafter at Contractor's discretion. Customer shall pay for the services and (including repair and maintenance) furnished by Contractor in accordance with the charges on the Contract Agreement, as adjusted by Contractor hereunder, upon completion. Interest will be charged on all accounts not paid when due at a rate of two percent per month, which is 24% annually. In the event that Customer fails to pay Contractor all amounts which become due under the Service Agreement or fails to perform its obligations hereunder, and Contractor refers such matter to an attorney or collection agency, Customer agrees to pay, in addition to the amounts due, any and all costs incurred by Contractor as a result of such action, including reasonable attornev's fees. CONTRACT ACCEPTANCE I,,..164 L, .,16 By signing below, owner agrees to our payment terms and accepts our Terms & Conditions. ACCEPTED B PRINT NAME: DATE SIGNED: DM ROOFING COMPANY INC. AUTHORIZED SIGNATURE: Summary Report Property Information Folio: 11-3205-024-0200 1411 NE 102 ST Property Address: Miami Shores FL 33138-2621 ROGERIO G CARRILLO &W Owner MIGDALIA L 1411 NE 102 ST Mailing Address MIAMI SHORES, FL 33138-2621 PA Primary Zone 1300 SGL FAMILY - 2801-3000 SQ 0101 RESIDENTIAL -SINGLE Primary Land Use FAMILY: 1 UNIT Beds / Baths / Half 4/3/0 Floors 2 Living Units 1 Actual Area 3,022 Sq.Ft Living Area 2,361 Sq.Ft Adjusted Area 2,569 Sq.Ft Lot Size 9,605 Sq.Ft Year Built 1954 Assessment Information Year 2019 2018 2017 Land Value $652,864 $528,6221 $528,622 Building Value $269,745 $269,745j $269,745 XF Value $28,682 $28,947 $29,224 Market Value $951,291 $827,314't $827,591 Assessed Value $355,794 $349,160 $341,979 Benefits Information Benefit Type 2019 2018 2017 Save Our Homes Assessment $595,497 $47$154'$485,612 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000, $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description APP! A11v' I Taxable Value Information Generated On : 11/1/2019 20191 20181, 20171 County - Exemption Value� --- $50,000 50,00 �$299,0160 $50000 Taxable Value $305,794 $291,979 School Board �. __ Exemption Value $25,000 $25,000 $25,000 Taxable Value $330,794 $324,160 $316,979 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $305,794� $299,160 vv $291,979� Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $305,794 $299,160! $291,979 Sales Information Previous Sale Price I OR Book -Page Qualification Description 12/01/1994 $317,500i 16620-2733 Sales which are qualified 07/01/1981 $225,000 11157-0713 Other disqualified 5 53 42 PB 56-86 MIAMI SHORES BAY PK ESTS AMD LOT 24 BLK 1 LOT SIZE 85.000 X 113 OR 16620-2733 1294 1 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www,miamidade.gov/info/discialmer.asp Version: Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: t0—'c4A-1a 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Property Addres Roofing Permit Number: Dear Building Official: I Nb.Y ( certify that I am not required to retrofit the roof to wall connections of my IJ building because: —41,the just valuation for the structure for purpose of ad valorem taxation is less than $300,000,00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) c�e..Y �o cc�r r Ella Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. ,1 n ✓'y Sworn to and subscribed before me this � day of _ w� � _ A CCCTTC ��ARG7 Notary Public, Sate of Florida at Large State �pP�V P`Bl �i I_IJJL 1 I L /"'.�v of Florida -Notary Public Commission # GG 15801 ;yf f.o°;� My Commission Expires July 2_ 2020 When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 P , '% dek , ENG NEERING 4225 SW 71 Ave, Miami. FI 33155 Tel: 786-398-9179 Fax: 786-800-2627 a1 roofinspectionC)o gmail.com LAB CERTIFICATION #16-0510.15 SITE SPECIFIC INFORMATION UPLIFT TEST — TAS #106 03/12/2020 Roofing Contractor DM ROOFING Permit # RF-11-192765 Job Address 1411 NE 102 ST MIAMI SHORES, FL 33138 Owner's Name ROGERIO G CARRILLO &W MIGDALIA L Type of Tile BARCELONA 900 Approximate Roof Height 12 feet Roof Pitch 4/12 Approximate Square Footage of Roof 33 ft2 Date Tested 03/11/2020 Number of Tests 55 Contact Name DENIS Date Installed Type of Access to Roof LADDER Required Testing Force 35 Lbs Testing Equipment F.G.E.100 Phone # 786-267-3066 LOCATION # OF TEST PASS # OF TEST FAIL Corner 5 Tests 5 Pass Test Fail Perimeter 9 Tests 9 Pass Test Fail Field 33 Tests 33 Pass Test Fail Ridge 8 Tests 8 Pass Test Fail TOTAL 55 Tests 55 Pass 0 Test 0 Fail IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTRY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL OISASTERS THIS REPORT IT IS NOT VALID FOR INSURANCE CLAIMS. Job Address 1411 NE 102 ST MIAMI SHORES, FL 33138 Permit Number RF-14-192765 Roof Drawing 49 9 7 6 23 33 s0 31 53 51 24 27 55 32 34 1 47 10 B 1 Z8 35 52 26 46 14 30 36 54 39 42 11 48 12 38 40 43 37 45 41 44 3 13 I% oekw INGIBIERING 4225 SW 71 Ave, Miami. FI 33155 Tel: 786-398-9179 Fax: 786-800-2627 a1 roofinspection(o).gmail.com LAB CERTIFICATION #16-0510.15 SITE SPECIFIC INFORMATION UPLIFT TEST — TAS #106 03/12/2020 Roofing Contractor DM ROOFING Job Address 1411 NE 102 ST MIAMI SHORES, FL 33138 Owner's Name ROGERIO G CARRILLO &W MIGDALIA L Type of Tile BARCELONA 900 Approximate Roof Height 12 feet Roof Pitch 4/12 Approximate Square Footage of Roof 33 ft2 Date Tested 03/11/2020 Contact Name DENIS Number of Tests 55 Permit # RF-11-192765 Date Installed Type of Access to Roof LADDER Required Testing Force 35 Lbs Testing Equipment F.G.E.100 Phone # 786-267-3066 LOCATION # OF TEST PASS # OF TEST FAIL Corner 5 Tests 5 Pass Test Fail Perimeter 9 Tests 9 Pass Test Fail Field 33 Tests 33 Pass Test Fail Ridge 8 Tests 8 Pass Test Fail TOTAL 55 Tests 55 Pass 0 Test 0 Fail IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTRY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL DISASTERS. THIS REPORT IT IS NOT VALID FOR INSURANCE CLAIMS. N �� � :i'i:� � JF • f�i 'te.N11'ENANg tL_EYVA•,��' Job Address 1411 NE 102 ST MIAMI SHORES, FL 33138 Permit Number RF-v1-192765 Roof Drawing a) C- ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 1 Florida Building Code 5th Edition (2014) - LJ�4A �V9 locity Hurricane Zone Uniform Permit Application Form. 1 .�' Section A (General Information) Master tl . Process No. 1 I 1 Contractor's Name 1 Job Address �n] ik& _x $L" *� • • • 1 ROOF CATEGORY • • : • •.:. • I ❑ Low Slope ❑ Mechanically Fastened Tile MortaWAiheeive Set 7iley • • ••..�• ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ WoodATng1as/Shakes• •: • • • ❑ Prescriptive BUR-RAS 150 ROOF TYPE • • • ❑ New roof ❑ Repair ❑ Maintenance Reroofing • • : •tit Reco verinq • • • O • ROOF SYSTEM INFORMATION • • • • • • Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSFA2.Uo Total (SF)Anato• • • • 1 Section B (Roof Plan) 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 1 IN �Nmin■OEM ■■ ■■■■►\�INN ■■■■�\■■ ■■ ■■PIP, ■In■■ ■■■■„■■■■V.�■■■■ ■ //w■N�� i■■■■��■■■■■ INN ■■Ing ■� ■■I�■■■■■ ��■�■■■■■■ I���■■■ ■■■ ■ ■ice �L�1 ■���� 0/till�■I/■ ■■■�® �.■■■■�■ ■■ ■ FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. 1 1 1 1 1 1 1 1 i El eaglevieww LENGTH DIAGRAM Total Line Lengths: Ridges = 31 ft Hips = 169 ft Valleys = 13 ft Rakes = 0 ft Eaves = 285 ft Premium Report 10/29/2019 Flashing = 7 ft Step flashing = 44 ft Parapets = 0 ft ... . ...... ... . .. ..... E S w Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5.0 Feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). i£ 2008-2019 Eagle View Technologies, Inc. and Pictometry Intema0onal Corp. —All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or incre of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125, 8,825,454; 9,135,737; 8,67U 061, 9,514,5v8, 8.P18,770; 8,542,80^; 4,244,589; 9,329,749; 9,599,466. Omer Patents Pen *ng. PAGE 4 eag leviewT� AREA DIAGRAM Total Area = 3,266 sq ft, with 9 facets. Premium Report 10/29/2019 ... . ...... ... . .. ..... .. .... ...... E S W Note: This diagram shows the square feet of each roof facet (rounded to the nearest Foot). The total area in square feet, at the top of this page, is based on the non -rounded values of each roof facet (rounded to the nearest square foot after being totaled). C 2008-2019 Ld^,le View Techn, ales, Inc. and Plctometry 'nternational Corp. —Ali Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos, 8,073,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,563; 8,816,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pend''.ng. PAGE 6 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 i 1 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOWi e e e Roof System Required Sections of the Permit Application Form Attachmentsdiequiled See List Below ' Low Slope Application A,B,C 1,2,3,4,5,6a�:.. Prescriptive BUR-RAS 150 A,B,C 4,5,6,r • • • ASphai' A,B,D 1,2,4,5 6 7 o 0 n rete or Clay ile Metal Roofs A,B,D,E 1,2,3,4,5,0ee A,B,D 1,2,3,4,!'.a8,%0: Wood Shingles and Shakes A,B,D 1,2,4,5,P,7 Other As Applicable 1,2,3,4,5,8,! • ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation ease.. e . eeeae e aaeaa ea eaaaa 0 ease a.a... a a' e aeeeea e a . a s e s . 00 aaae 15.36 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) t I ! I 1 1 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: Notice of Acceptance Numb Minimum Design Wind Pressur s If A plicable (From RAS,1Z7 or Calculations): P1: P1: P1: _�.,� Deck Type: Type Underlayment: O.5 1 �•" • �j`••� R f Slope: 11 lug II 12 ....... _.. Insulation: •• •• �•••• Fire Barrier: .. . Ridge V nt'la ' ? Fastener Type & Spacing: C (�� 1 I•.�ji/�/ Adhesive Type: 1 Type Cap Sheet: 1?o1AGvxZ:-:TRj:1U<7)1 1 1 1 Mean Roof Height: Roof Covering: ,y�D`�N� �f'`n — , 1 �—�-b �► 1 Type &Size Drip Edge:la?_)V FLORIDA BUILDING CODE -- BUILDING, 5th EDITION (2014) 15.39 1 1 Copyright to, or licensed by, ICC (All. RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mf values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable. t �MNethod 1 "Moment Based Tile Calculations Per RAS 127" 22 (P1 x k i�.d = � . - Mg: M„, �, - Product Approval M, (P2Qx% _ - Mg: = M� I Product Approval Mf �*� (P3.1 x� , _ _) - Mg: V - Mr31631 Product Approval M, .•• Method 2 "Simplified Tile Calculations Per Table Below" • • • • • • • v Required Moment of Resistance (M,) From Table Below Product Approval M, • M, required Moment Resistance` • • • Mean Roof Height Roof Slope 15' 20' 25' 30' 2:12 34.4 36.5 38.2 39.7 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 SZ.3 5:12 28.4 30.1 31.6 32.8 w3 .9 6:12 26.4 28.0 29.4 30.5 32.4 k 7:12 24.4 25.9 27.1 28.2 30.0 `Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F with the values for Fr. If the F values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1: x L _ = _ x w: = _) - W: _ x cos O _ = F,, _ Product Approval F' (P2:_ x L - = _ x w: = -) - W: x cos 0 - = F,� _ Product Approval F' (P3:_ x L - = _ x w: = _) - W: x cos O _ = F„ _ Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 8 Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity Ms Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Ma Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) t t ' I I Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. OR 5N'c, FGOR SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. AddUionav, the following items should be addressed as part of the agreement between the owner ant the cogtractor.:tVdlAner's ...... initial in the designated space indicates that the item has been explained. • 00*0;: • :..... 2. Renailing wood decks: When replacing roofing, the existing wgatl•it deck MaV40ye to be renailed in accordance with the current provisions of Section R4403. (The ro6fddck is us6ally •• ••••• ••••� . concealed prior to removing the existing roof system). .0:0a .. .. .. ...0 •••••• 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the:Mf decking • • •• •. can be viewed from below. The owner may wish to maintain the architectural aDpoaraZce; therefore+ �•••• roofing nail penetration of the underside of the decking may not be acceptable. This provides t4vmtion of maintaining the appearance. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is t overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. nfs Signature Date Contractor Signature Date 1 q)1 Az • Lu4 c sk- CMS Property Address Permit Number Revised on 7/9/2009 LD;07/01/2015; MIAMI DARE MIAM[-D.4DE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of coxstrLIOtion materta s. The • • • • • • documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Controj ��jtpn to be •, used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdic'ttdtitAHJ). ' •••••• • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County.'t'btl Wt Coit"l.$ection' (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the rioght to have this • •: 0 •. product or material tested for quality assurance purposes. If this product or material fails to peO 'il; in the aje�pted • manner, the manufacturer will incur the expense of such testing and the AHJ may immediatelX j:�gke, modify, or . • suspend the use of such product or material within their jurisdiction. RER reserves the right:o rt4ke this acceptance,...:. if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet t e • requirements of the applicable building code. • • • • • This product is approved as described herein, and has been designed to comply with the Florida Building MUM including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 16-0711.01 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino 19 NOA No.: 18-0509.15 Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 1 of 8 ROOFING ASSEMBLY APPROVAL Category: Rooting Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. • •••••• 2. PRODUCT DESCRIPTION • • • ...... . ...... Manufactured by Test Proijuct • 000000 Applicant Dimensions Specifications ... Des.�riptfon • • • • • • Barcelona 900 Length = 17" TAS 112 00000 High profile, interloekirg! Qne-p4c�,•'S;shapo&, • • • Width = 13" Type — la high-pressure extrudM dblicrete rcto"Me • •' •, • '/2" thick equipped with three i-aiMUes. For ddrect deck •• . . . . . or battened nail -on, niechjm.cally *sta-..... ed, • • mortar set or adhesi\;44et *plica4ions• ; • • • •; • Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete Width: varies roof pieces for use at hips, rakes, ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polysc0" AH-160 TILE BONDTM Roof Tile Adhesive DAP Foam Touch N Seal StormBond"8' 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company DAP Foam Inc. NOA No.: 18-0509.15 Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 2 of 8 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108(Nail-On) Redland Technologies P0402 Withdrawal Resistance • Sep.t. 1993 Testing of screw v$. smooth • • • • • • shank nails ' ' Redland Technologies Letter Dated Aug. 1, Wind Tunnel 're';f tA' ' Aug. 1994 1994 TAS 108 (NaitUn�:* �� �••••� Redland Technologies P0631-01 Wind Tunnel TestifR�� J u1y 1994 • • • • • TAS 108(Mortaf$tf� �••� •••••� Professional Service Industries, Inc. IC-1320-94 .. .. Physical Propj�s.. .... ...... Feb. 1995 .' TAS 112: ' : ....:. The Center for Applied Engineering, Inc. 25-7688-3 TAS 101. (Adhesive hey June 1996 :....: 25-7688-10 TAS 101 (Mortar Set) •J}j;•1996 The Center for Applied Engineering, Inc. 25-7688-5 Static Uplift Testing June 1996 TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) The Center for Applied Engineering, Inc. 25-7688-4 Static Uplift Testing June 1996 TAS 102 (4" Headlap, Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier 09/01/16 Walker Engineering, Inc. Evaluation Restoring Moments Due to 09/01/16 Calculations Gravity American Test Lab of South Florida RT0617.03-16 TAS 112 06/29/16 PRI Construction Materials Technologies COPO-002-02-10 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-02 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-01 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) NOA No.: 18-0509.15 MIAMI•DADECOUNTY Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 3 of 8 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may require, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Department of Regulatory and Economic Development — Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be i ,,complianeQNith • • • • • • applicable building code. • * 0 0 V O . ...... ...... 4. INSTALLATION 000000 • • • ...... . .. .... . .. 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict. eompliance wrthegoofing••• • Application Standard RAS 118, RAS 119, and RAS 120. ;";•; ' 4.2 Data For Attachment Calculations : • • •: • • • • • : • Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - It (ft3) Tile Profile A (ft3) Batten Application j\ (ft3) Direct Deck Application Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 2":12" 311:12" 4":12" 5":12" 6":12" 7":12" or greater Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 6.60 5.76 6.42 NOA No.: 18-0509.15 Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 4 of 8 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) • Barcelona 900 2-10d Ring Shank Nails 28.6 V.2.•. 19.4 •• 1-10d Smooth or Screw Shank 5.1 6.16 :...2.8 Nail ••���• •� 2-10d Smooth or Screw Shank 6.9 9.z.. 1.3 ;• Nails '....' :""' .. 1 #8 Screw 20.7 20.7•.. . 0148.1 .. 2 #8 Screw 43.2 43.2• • 00429.8 • • 1-10d Smooth or Screw Shank 23.1 21.1:0: 19.0 Nail Field Clip):•••0• 1-10d Smoothor Screw Shank 29.3 2�,.�• ; 44.0 ;• Cl ;•. 2-10d Smooth or Screw Shank 27.6 27.6 38.6 Nails Field Clip) 2-10d Smooth or Screw Shank 38.1 38.1 41.8 Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4" the headlap and fasteners are located a min. of 2'/2" from head of tile. NOA No.: 18-0509.15 Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 5 of 8 Table 6: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Paddy Adhesive' Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 Tile BondTMOne Component Roof Tile Adhesive 29.32 ICP Adhesives Polyset® AH-160 two -component foam 29.33 DAP Foam Touch N Seal StormBond®2 Roof Tile Adhesive 664 1 See manufactures component approval for installation requirements. 2 TILE BONDTm Roof Tile Adhesive; Average weight per paddy 10.7 grams. . .. 3 ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160; Average weight per paddy I:gram. 4 DAP Foam Touch N Seal StormBond® Roof Tile Adhesive Two -Component; Average wei ••�• add .$ rams. .. .... . . ...... Table 7: Attachment Resistance Expressed as a Moment - Mf •IP••;••• for Single Paddy Adhesive Set Systems 00 ...... . Tile Tile Application 6nimum Aitacbment Profile . . • • Resisianig • . Barcelona 900 ICP Adhesives Polyset® AH-160 two -component foam 66.5• • • ICP Adhesives Polyset® AH-160 two -component foam 38.76 DAP Foam Touch N Seal Storm Bond® 2 63 7 DAP Foam Touch N Seal StormBondV 2 828 5 Large paddy placement of 63 grams 6 Medium paddy placement of 24 grams 7 Medium paddy placement of 30 grams 8 Large paddy placement of 60 grams Table 8: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set9 24.5 9 Seespecific mortar manufacturers Notice of Acceptance NOA No.: 18-0509.15 1111FMIAMMADE Expiration Date: 04/26/22 .. ' ,.S - Approval Date: 06/28/18 Page 6 of 8 ... . . ... 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BARCELONA 900 TILE LAKE WALES FLU PLANT 2 * • • • * • ...... LOCATED UNDERNEATH TILE 9.6 • • ...... . ...... 6. BUILDING PERMIT REQUIREMENTS •"•"• . . ...... 6.1 Application for building permit shall be accompanied by copies of the following 0 0 0 0 0 . 6.1.1 This Notice of Acceptance. .. .. .• • ... ...... 6.1.2 Any other documents required by the Building Official or applicable bui &&rode in order to . • properly evaluate the installation of this system. : • : • . ...... . . ...... .. . . .. . . . . NOA No.: 18-0509.15 Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 7 of 8 PROFILE DRAWING NAIL HOLES UNDERLOCK LOCK 131, BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE ...... • . . . . ...... NOA No.: 18-0509.15 Expiration Date: 04/26/22 Approval Date: 06/28/18 Page 8 of 8 MTAMI= MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami. Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44"' Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Fection to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdictit)n (f VJ). • • • • • • • • • • • •• • • • •' This NOA shall not be valid after the expiration date stated below. The Miami -Dade CountyAoduct C&1?o1'8ectiog**,:. (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the•rig6 ro have this produc• • • or material tested for quality assurance purposes. If this product or material fails to perform irtif1v%ceptelmjtMer, the* • manufacturer will incur the expense of such testing and the AHJ may immediately revoke, mddi", or suspend the use •: • • • of such product or material within their jurisdiction. RER reserves the right to revoke %*S*1ccept:nre,%f it is""' •• •• •••• •••••• determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements • . . . of the applicable building code.:00• . . ...... This product is approved as described herein, and has been designed to comply with t* Fjeyda Building Codg • • • • including the High Velocity Hurricane Zone of the Florida Building Code. " ' •. • .. . DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polysete AH-160 as manufactured by ICP Adhesives and Sealants, Inc, as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset' AH-160. ...... PRODUCTS MANUFACTURED BY APPLICANT: of •••••• • Product Dimensions Test Product'l5tiMptioi? • • • • • • Specifications 000000 ; .... ICP Adhesives N/A TAS 101 Two component polywsweane foam adhesive.... Polyset'AH-160 • • • • • • • • • • • • • • ICP Adhesives Foam N/A Dispensing Equipment • • • • • • • • • • •: • Dispenser RTF1000 • . . . . ...... ICP Adhesives ProPack* N/A Dispensing Equipmenj • • • ; • • • • 30 & 100 • PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset' AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test Results ASTM D 1622 1.6 lbs./ft.' ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise ASTM D 1623 28 PSI Parallel to rise ASTM D 2127 0.08 Lbs./Ft2 ASTM E 96 3.1 Perm / Inch ASTM D 2126 +0.07% Volume Change @ -40' F +6.0% Volume Change @158°F., weeks ASTM D 2856 86% 2 weeks 100% Humidity, 2 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services LIMITATIONS: Test Identifier #94-060 257818-1PA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[ 1 ] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 ASTM D 1623 ASTM E 108 '..' ASTM E 108 •••�•• ASTM E 84 .••••• TAS 114 •�:••: ASTM D 1623 • TAS 101 TAS 123 TAS 101 TAS 101 TAS 101 Date 04/08/94 12/ 16/96 10/25/95 11/02/95 12/12/95 02/01 /94 ...... 0Z0/93 11/16/94 . 03:14 §9. 04/ 18/11 02�21/12 ...... 10/23 W 12/28/98 03/02/99 I. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 1CP Adhesives Polyset' AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset' AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives PolyscCAH-160. 2. ICP Adhesives Polyset' AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset' AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset" AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhes3��3nd Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicatorso•tlif authority having "`":` jurisdiction. ...... •..... 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is regdited before apl3lication ; •; of any adhesive. The mix ratio between the "A" component and the "B" component shaU'l3e•?aintai4wd between • • 1.0-1.15 (A): 1.0 (B). "`• ""` ...... . .. ..... 6. ICP Adhesives Polyset' AH-160 shall be applied with ICP Adhesives Foam Dispenser RTN40 or rC40606 0000:6 Adhesives ProPack' 30 & 100 dispensing equipment only. • • • • • • • . . . . ...... 7. ICP Adhesives Polyset' AH-160 shall not be exposed permanently to sunlight. ; • • • • • • 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after tCP A0hgs'iv;s • Polyset' AH-160 has been dispensed. 0000 9. ICP Adhesives Polyset' AH-.160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Minimum Paddy Contact Minimum Paddy Gram Tile Profile Placement Detail Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 2 grarn9poi:paddyeee head of tile 9-11 sq. inches at*,,.**: overlap • •••••• Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 7 grams peer bead �.. edge) 20-25 sq. inches each • e • • • • • • • • bead • • • • • • . .•.. . .. ... Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches grams upderpan••• a eer34 •. • • . •.•••• • • • • • LABELING: " • All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 lWltlu•u,Itmastic c""Wi. � Paddyrti•nsaiNTSO {r1►r =lrad/. (iNtladaymeas � ° •4 ` }t +ti 1•irt iasta a apliond .� ° },,.i ID r EMwClhsura '`.�"f Nell thrDw1h plastic mne"d Iwhen reQrirem I I -,Ns apt, Mal ItIle zrn. .,N, -` diva dasrrn EaRecaursa •—Resd• KA gkw*ugfi plwstit ("en forltd^"d) or Idl t8ero1•th 1eF a. Unt6a'tyyntwtt oi` 2 � :1n. wlda aptl•n9t `� Ea►» caum ti Pasch k Weephok 'tWc!•srre is [Fall 1,,. Drip •d" . • 10 • APPROVED Flat/Low Profile Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. .••••. ••••••• • •••••• •••••• 041414100 Medium Profile / Double Patl•'fiile • ••••• •••••• • •• •••• •• • 1. Starting at the cave course apply a mfnftl!M% 2" • •• •; • (50.8 mm) x 10" (254 - is F. (25.4 mi �) foam000000 paddy onto the underlaymegpositicpW*"shown • under the pan portion of Wti=e closest W the ; • • • •; overlock of the tile being set. ••:••• 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the the closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (l 09.7 cm2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 wn tbr6unh ptaala c+ma vndldy RM"" T" Owhw MQU"d')t �letlaaisyrnofit �\�/' „ s4 71 x each iapli.n.I /"�� 5awtaursr �°�-�` u .tom ✓ ate. sip,. N�- Flat/Low Profile Tile Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm 2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum Y (50!8mm) x 7" (177.8 mm) x 1 " (25.4 rpm) Rjpm paddy onto the • . • • ; • underlayment positioned as sllMvn Under ihe... ' • strengthening rib closest to tiles W'Aock of the tile being set. • • • .... . ..... 3. Continue in same manner. Ins}lr"glaproxitiatel}, 10" ..... (64.5 cm2) - 12(77.4 cm2) squaS`e rich ad1v*vo • • • • • • • contact with the underside of the•tile. • . . . . ...... Medium Profile / Double Pan Tire . • • Starting at the cave course, apply a minimum 2" (50.8 mm) x 1.0" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) kaA dhreughv u * earment--, f"em rida`rl�rrd1? f P.ddy tS.raaMA Till Undwiar'ywrwrrt . ""-. NZ f. smarts optimal r � �. 10fin. 1, s� 41n. Ortpad" APPROVED High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 CM2) square inch adhesive contact with the underside of the tile. At the second course, applya minimum 4P(50.8mm) • • •; • x 7" (177.8 mm) x 1" (25.4 mrn) Roam p;00X:4ito the underlayment positioned as'Sht it Linde? the pan :***a: portion of the tile closest to'tWoverlock of the tile : :a***: being set. • • • • • • •aa• . •aaa• Continue in same manner. ."..;pprJj1i:;ly l 7" :::::a (109.7 cm2) - 19 (122.6 cm244;yua6e inch adhesive • contact with the underside & the t►le. • • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Nall through plastic cernent. Paddy (between tiles) !when requiredi Battens optional Paddyiundertle! single paddy an top of tfle axdin. �` singglepad under Ulp shrgle paddy on mderlayment. *t2X 411 10 in..ti +"Z in EaveClosure HattLow Profile Tile Nag through plastic cement Single paddy under tille. twhen required! Paddy (between tilesi Battens Paddy fonder tile} optional Single WdY an top of tie ` 4x41n. �+ 2x4in. S[rwlepaddyon unddertayment 10 in. 2 in. y Ear"Closure Eave Course Fascia Medium Profile Tile On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 min) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in2 (109.7-148.4 cm2� of adhesive contact with the underside Qf riv-Sle ...... •••••• • •••••• Apply a 4" (101.6 mm) Y. 4.:(.1� 1.6 mm)•x 1 " (25.4 • mm) foam paddy onto toe andjrlayni;ej-4 j4�t below • the second course line poSitfdhed foam paddy • •: • • • under the strengthening flhfdr flat tile, erilrider V • • . ...... pan portion of the tile, ctoses. .tto the uriaerlock for • the second course the too�be rns3alled..Insure ••�•; approximately 8-9 in' (5.1.6-5j .1 cm�•d1•ddhesivq, contact with the undersih oT tle tile.. .. • •: (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail through plutic c Single paddy under tile twhen requ ired) Paddylbetweentiles I Battens " optional Paddy (under tile) �Singlepaddy on unfixrtayanen .mow f'4 x 4 in. t Single 2 x 4 in. ddddyy on pofnle Eaw Course asda Y weq*ole Coln. Erie downs �2in. Dripedge High ProffleTll4a 3. Also apply a 2" (50.8 mm) x 4" (10 1.6 mm) x 1/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm') - 11 (71cm') square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm) - 9 (58.1 cm'-) square inch adhesive contact with the underside of:beAs at the head of the tile. Contipue 6n same manner. • • • •••••• • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL t) Place enough adhesive to achieve 65 to 70 sq in. Steep pitch applications in contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive in to t in.from outside edge of cover tile. Then install the tile. Ensure 20 to 25 4. In. contact area. IUnderlayment Eave closure (motar shown) Fascia Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 min) x 10" (254 mm) x 1" (25.4 min) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support cave tiles from rocking until adhesive has a chance to cure. Continue in same manner bringing t$vapla courses up toward the rM ee I insure • ****:a approximately 65 (419.40 inn)* 70 ( 5i !Ei em2) • • •„• square inch adhesive co"4q. yith the uiulerside e of the pan tile. .... .•.••• .... . ..... Turn covers upside dowYr exh;sing tre jftid;rpide• •' • • of the tile. Apply a mini"Um? 1 " (25.4•ftttil) x 10" • • • *0 (254 mm) bead of adheZ'bl!"Cectly on tAe inner •. edge of each side of the coverlile. Learn: • • • •• • • approximately 3/4" (19 ;n tQ 1 " (2� .4 gym) ; • • • • from the outside edge of the tile, invJ'arQ, tc of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm'-) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 min) x 4" (101.6 min) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 MIAMNDIADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11905 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economy Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control ►V,; 1JiD1a to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction OjiJ). ""' • • • . . .....• This NOA shall not be valid after the expiration date stated below. The Miami -Dade County P'1Utmttf Control Section • • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the fithi to have this • • • • product or material tested for quality assurance purposes. If this product or material fails to pe-r `or � to the ieeepttd • • manner, the manufacturer will incur the expense of such testing and the AHJ may immediately,;("(&, modifypr ..:..' suspend the use of such product or material within their jurisdiction. RER reserves the right to r%Qre this aceQp[ance, • • • • • • if it is determined by Miami -Dade County Product Control Section that this product or material•feils4 o meet the • • requirements of the applicable building code. :0 This product is approved as described herein, and has been designed to comply with the Floria Building Code • • • • • including the High Velocity Hurricane Zone of the Florida Building Code. • DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages I through 8. The submitted documentation was reviewed by Freddy Semino. 0 NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick IR-Xe Mam facluring Location # 1 & 42 Polystick Dual Pro Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick TU Max Manufacturing Location #1 & #2 Polystick TU P Manufacturing Location #2 Polystick TU Plus (Surface Printing) Manufacturing Location #1 & #2 Polystick MTS Manufacturing Location #2 Polystick NITS Plus Manufacturing Location #2 Elastoflex S6 G Manufacturing Location #2 Test Product Dimensions Specification Description 65' x 3'3-1/8" ASTM D 1970 A fine granular/sand top surface self -adhering, APP Or 65' x 3' polymer modified, fiberglass reinforced, bituminous 60 mils thick sheet material for use as an underlayment i4sloped roof sees.. assemblies. Designed as an ice.& rain shield. • • • • • • • 6 P x 3'3 '/s" *see . TAS 103 and A rubberized asphalt self-adhe�pg,glass-fi112. ll;lyester....:. 60 mils thick ASTM D 1970 reinforced waterproofing memliiwt. Des ignedas a • sees.. metal roofing and roof tile and enlarice nt. • ; e • e sees . sees. 61' x 3'3-1/8" TAS 103 and A rubberized asphalt self-adhering.glass-fiber/pWl ester..:..' 60 mils thick ASTM D 1970 reinforced waterproofing memhran¢.besigri64m,a meta+•••;• roofing and roof tile underlayment.:•: •. 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self -adhering, polyeste* reinforced • • 60 unils thick ASTM D 1970 waterproofing membrane. Des►gntd as a a rpof ti% • e • • underlayment. 0000 32' l0" x 3'3'/8" TAS 103 and A rubberized asphalt waterproofing membrane, glass- 130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface designed for use as a tile roof underlayment. 65' x 3'3'/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. 65'8" x 3'3'/s" TAS 103 A homogeneous, rubberized asphalt waterproofing 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. 65'8" x 3'3-1/8" TAS 103 A homogeneous, rubberized asphalt waterproofing 60 mils thick membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. 32'10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane ASTM D 6164 with a sanded back face and a granule top surface. For use in roof tile underlayment systems. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED Test AEency Test Identifier Test Name/Report Date Trinity ERD P10870.09.08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 0 09/41/11 P37300.10.11 TAS 110/ASTM D4798 & D1970• • 10/19/11 P40390.08.12-2 ASTM D 1623 . • . : p$/.( 12 P37590.07.13-1 ASTM D6164 "':" 007/02/13 P45270.05.14 TAS 103, TAS 110 & ASTM061tll 0571�/14 P46520.10.14 ASTM D1623 •,,,,• :2e1 ?-,14 P44360.10.14 TAS 103 & TAS 110...... .10/"7/14 P43290.10.14 ASTM D 1970 & TAS 1400 9 e * � 4/o]•7/ 14 PLYG-SC10130.06.16-3 TAS 103 & TAS 110:••:•: 06/27/16 PLYG-10130.06.16-1 ASTM D1970 & TAS 1?0 @ :a6/2%16 . PRI Asphalt Technologies PUSA-035-02-01 TAS 103 �••� 0 :09,t%06 PUSA-055-02-02 TAS 103 12nU/07 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798 & G155 04/01/08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX23D8B TAS 103/ASTM D4798 & G155 02/18/10 DX23D8A TAS 103/ASTM D4798 & G155 02/18/10 LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building pen -nit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. ...... Deck Type 1: Wood, non -insulated '• • ...... . ...... Deck Description: Min. 19/32" plywood or wood plank 000090 • •; "" System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered . • • • • • .... . ..... Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. • • • • • • • • • •' • • Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" �� 1grid, 6 o.c. at a 11!'l1Yl•tlm 4" head la •(for• • P• .' base sheet only) . . ' . . . ' ...... Membrane: Elastoflex S6 G, hot asphalt applied .'. ..0% Surfacing: See General Limitations Below. so• ' • • Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick NITS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 17-061.4.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 1 11. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of Y and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have frill contact with the surface, giving specu%ait4tion to lap areas. : • • 000000 . . 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembl}i current Pralin`•Control...:. Notice of Acceptance. ...:.. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The ffl wg tapQ ehatl.be • pressed in place and formed around the protrusion to ensure a tight fit. A second laye.r oel;olystick shall. be ..... ••�••• . ..... applied over the underlayment. • . .. .. .... ...... ...... . GENERAL LIMITATIONS: . . • . . ...... ...... 1. Fire classification is not part of this acceptance. • : .. : 06906 : 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Pius inay be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Ex osure Limitations (Days) MTS IR-Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A N/A N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 Rule 61 G20-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick NITS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) I Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick SyUQw:(.E3) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus. • MTS Plus with • Dual Pro To Pigs Flat Tile Prohibited 4:12 6:12 6:12 5:1 2 • • • *0 6: t 2 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6: j2 Tile without battens � • � � • • 10. . .... ...... The above slope limitations can be exceeded only by using battens in accordance with ;he V1;roved Tile System 000000 Notice of Acceptance and applicable Florida Building Code requirements. When battgps arF requi jltl'tltey shall be utilized during loading and installation of tiles. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropliing of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. 7V _ UMAII.K IU HUS NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick 1R-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. •••••• POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICU, 1 JV.MBR'ANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPEMWAPPLICATIONS. .... • LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMNI I)AT104S. 0 0 • • •••••• 1. Polyglass does accept the direct application of Polystick underlayment membranes to w4w4le tiecks..InskAlers ara • 9 • • cautioned to refer to applicable local building codes prior to direct deck installation tout stele this is TLeeptable.• •• •; • Please also refer to applicable Product Data Sheets of the corresponding products. ' . . . • ...... 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as p&*Polyglass . Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimurn•1•%"emetaledisk-es :0 000 required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a 1 46Gm rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of TV12" or greater. it is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premiu n Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures asSoutlined by the National Roofing Contractors Association (NRCA). . . :""` • • • •• • • • PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPOVIRV PPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMIJgWATIONS. . •••••• • • 9 : ••••: •••• • ••••• END OF THIS ACCEPTANCE ":": : •"• .. .. •••• ...••. ...... . . . . • •. • . •• .. • 6000 00 •••••• • • NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8 of 8