Loading...
RF-19-2520Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address 101 NW 100TH ST, Miami Shores, FL 33150 Contacts lf'� J� �lUl7L Issue Date:10/29/2019 Parcel Number 1131010220300 Permit NO.: RF-10-19-2520 Permit Type: Roof Work Classification: Tile Permit Status: Approved Expiration: 04/27/2020 TAMARA MAGALHAES Owner RAY FLORIDA ROOFING Contractor 101 NW 100 ST, MIAMI SHORES, FL 33150 MIRCEA TUDUCE Mobile: 7862414639 2180 NOVA VILLAGE DL, DAVIE, FL 33317 Business:5612550134 RAYFLORIDAROOFING@YMAIL.COM Inspection Description: RE- ROOF SLOPE TILE Valuation: $ 12,500.00 Inspectson Requests: 4949 Total Sq Feet: 1,500.00 Fees Amount Application Fee - Other $50.00 CCF $7.80 DBPR Fee $4.13 DCA Fee $2.75 Education Surcharge $2.60 Roofing Fee $225.00 Scanning Fee $9.00 Technology Fee $6.88 Total: $308.16 Building Department Copy Payments Date Paid Amt Paid Total Fees $308.16 Check # 3280 10/28/2019 $258.16 Credit Card 10/23/2019 $50.00 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the wRrk stated. Authorized Signature: Owner / Applicant / Contractor / Date October 28, 2019 Page 2 of 2 Miami Shores Village ENTERED C,Ca Building Department OCT 282019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 --4EL' Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201 i- LC4-" BUILDING Master Permit No.F (���q ' a•5��-� PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC (] ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 101 nw 100 st City: Miami Shores Co ntv Miami Dade Zip: Folio/Parcel#: 1131010220300 Is the Building Historically Designated: Yes NO Occupancy Type: sfh Load: Construction Type: Flood Zone: BFE: FIFE: OWNER: Name (Fee Simple Titleholder): TAMARA FRANCO MAGALHAES Phone#: 7862414639 Address: 101 NW 100 ST City: MIAMI SHORES state: FL 33150 Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: RAY FLORIDA ROOFING Phone#: 5612550134 Address: 2180 NOVA VILLAGE DR City: DAVIE state: FL Zip: 33317 Qualifier Name: MIRCEA TUDUCE Phone#: 5612550134 State Certification or Registration #: RC29027485 Certificate of Competency #: 15BS00224 DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: -90 _ pp Square/Linear Footage of Work: s� Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of work: REROOF SLOPE TILE Specify color of color th�ru the:�/eRi,- _ n� coco— Submittal Fee $ �`(Permit Fee $ OL-1 CCF $ • �� CO/CC $ Scanning Fee $ • W Q Radon Fee $ a. DBPR $_ 3 Notary $ 0 Technology Fee $ V Training/Education Fee $ (4p Double Fee $10 Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ —1 `./ ' , (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first ins ec ion which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will tot fie approved and a reinspection fee will be charged. Signature7Q)�� �"MOSignature OWNER or AGE CONTRACTOR The foregoing instrument was acknow edged before me this The foregoing instrument was acknowledged before me this day of OC'T — 20 11 by day of •�- 20 /�' by who is personally known to &i -4 A 7ud cr t2- who is personally known to me or who has produced d c-- me or who has produced 'd �� as identification and who did take an oath. -� t ; • identification and who did take an oath. u••, NOTARY PUBLIC: � y NOTARY PUBLIC: rn 0 Z3 m 0 D Sign: rnr X Sign: Print: 5W^1/iF-- %14,d4 c.z 1 v 7, 0 Print: S`/�1/d✓ iS�,�ate- a Z T� Seal: o r ry Seal: �° s SONIA RAMONA TUUUCE O ( .y90RUT M N iP "RE �'' ••• My COMMISSION M FF954374 �. **A ro <- n O V R1 , W Ccrrss;c(� 289298 da n 1 MY CO^m ... ~ " xAirEs Jan t ** ats**f+WiiiiaElretay�2f9* **** , flotgallo:a SeNicr..ten' ySo.'1C.'r�3':8-C'S! fr Z, 5 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Ron DeSantis, Governor Halsey Beshears, Secretary a bpr STATE OF FLORIDA DEPARTMENT OF BUSINESSAN�DPROFESSIONAL REGULATION CONSTRU THE ROOFING C PROVISCO G BOARD R ,ED UNDER THE EXPIRATIONDi4.. _ TE;sAUGUST 31, 2021 Always verify licenses online at MyFloridaLicense.com Do not alter this document in any form. This is your license. It is unlawful for anyone other than the licensee to use this document. 11 ■ BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2019 THROUGH SEPTEMBER 30, 2020 I DBA: RAY FLORIDA ROOFING LLC Receipt #:ROOFi G/SHHET METAL CONTRACTOR Business Name: Business Type: (ROOFING) ' Owner Name: MIRCEA R. TUDUCE Business Opened':05/16/2012 ' Business Location:21.80 NOVA VILLAGE DR State/County/Cert/Reg:12-R-17730-X DAVIE Exemption Code: Business Phone: 561-255-0134 Rooms Seats Employees Machines Professionals 2 For Vending Business Only Number of Machines: Vendina Tvoe: I Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 27.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature, You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. t Mailing Address: MIRCEA S. TUDUCE 21.80 NOVA VILLAGE DR DAVIE, FL 3331.7 2019 - 2020 Receipt #02A-18-00007347 Paid 07/08/2019 27.00 Policv Number: Date Entered: CERTIFICATE OF LIABILITY INSURANCE [ITE (MW DD/YYYY) /15/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURERS), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terns and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER SALMEN INSURANCE 730 SW 4TH 3T. M3 CAPE CORAL, FL 33991 CONTACT ' NAME: PHONE , (866) 587-7147 FAX No: (888) 542-3507 EMAIL ALLISON@SALMENINSURE.COM ADDRESS: INSURERS AFFORDING COVERAGE NAIC # INSURER A: Pl2EEFRRIM TRACTORS INS. 00' (i5 ) 12497 INSURED RAY FLORIDA ROOFING LLC INSURER B : INSURER C INSURER D: 2180 NOVA VILLAGE DR. INSURER E: DAVIE, FL 33317 INSURER F : COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. WSR LTR TYPE OF INSURANCE2111L ADDL SURR JUL POLICY NUMB ER POLICY EFF MM/ DD/YYYV POLICY EXP MW DDMYVY LIMITS p COMMERCIAL GENERAL LIABILITY CLAIMS MADE ®OCCUR PC306702 4/16/2019 4/16/2020 EACH OCCURRENCE $ 1,000,000 PREMISES Ea occurrence $ 50,000 MED EXP (Any one person) $ 5,000 PERSONAL & ADV INJURY $ 1,000,000 GENT AGGREGATE LIMIT APPLIES PER: POLICY ❑ jE T LOC OTHER: GENERAL AGGREGATE $ 1,000,000 PRODUCTS -COMP/OP AGG $ 1,000,000 $ AUTOMO BILE LIABILITY ANY AUTO OWNED SCHEDULED AUTOS ONLY AUTOS HIRED NON -OWNED AUTOS ONLY AUTOS ONLY Ea accident $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ Per accident $ UM3 RELLA LIAB EXCESS LIAR HCLAIMS-MADE OCCUR EACH OCCURRENCE $ AGGREGATE $ DED I RETENTION $ $ WORKERS COMPENSATION ANDEMPLOYERS'LUIBILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) V yes desorbe cler RIPTION OF OPERATIONS below DESCu NIA - STATUTE I I ER E.L. EACH ACCIDENT $ E.L. DISEASE - FA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, maybe attached it more space is required) *Subject to all policy terms, exclusions and conditions* I rK I It -ILA I C nULUCR %oPU-4l/GLLN I IVIN MIAMI SHORES VILLAGE BLDG DEPT 10050 N.E. 2nd Avenue Miami Shores, Florida 33138 ACORD 25 (2016/03) SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE 0)1988-2015 ACORD CORPORATION. All rights reserved The ACORD name and logo are registered marks of ACORD Produced Using Forms Boss Plus software. www.FonnsBoss.00nl; knpressive Publishing, LLC 800-208-1977 CERTIFICATE OF LIABILITY INSURANCE Date 10/15/2019 Producer: Plymouth Insurance Agency This Certificate is Issued as a matter of Information only and confers no 2739 U.S. Highway 19 N. Holiday, FL 34691 rights upon the Certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. Insurers Affording Coverage NAIC # (727) 938-5562 Insured: South East Personnel Leasing, Inc. & Subsidiaries 2739 U.S. Highway 19 N. Insurer A: Lion Insurance Company Insurers' 11075 InsurerC: Holiday, FL 34691 Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD Type of Insurance yP POIIC Number Y Policy Effective Date Policy Expiration Date Limits (MM/DD/YY) (MM/DD/YY) GENERAL LIABILITY Each Occurrence Commercial General Liability Claims Made11 Occur Damage to rented premises (EA occurrence) Mad Exp Personal Adv Injury General aggregate limit applies per: General Aggregate Policy ❑Project ❑ LOC Products - Comp/Op Agg AUTOMOBILE LIABILITY Combined Single Limit Any Auto (EA Accident) Bodily Injury All Owned Autos Scheduled Autos (Per Person) Bodily Injury Hired Autos Non -Owned Autos (Per Accident) Property Damage (Per Accident) EXCESS/UMBRELLA LIABILITY Each Occurrence Occur 0 claims Made Aggregate Deductible A Workers Compensation and WC 71949 01/01/2019 01/01/2020 X WC Statu- I OTH- Employers' Liability tory Limits ER E.L. Each Accident $1,000,000 Any proprietor/partner/executive officer/member excluded? NO .L. Disease - Ea Employee $1,000,000 If Yes, describe under special provisions below. rE .L. Disease - Policy Limits $1,000.000 Other I Lion Insurance Company is A.M. Best Company rated A (Excellent). AMB # 12616 Descriptions of Operations/Locations/Vehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 91-68-614 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company': Ray Florida Roofing LLC Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or email certificates@lioninsurancecompany.com Project Name: ISSUE 10-15-19 (SS) Benin Date: 1 4 2 17 CERTIFICATE HOLDER CANCELLATION MIAMI SHORES VILLAGE BUILDING DEPARTMENT Should any of the above described policies be cancelled before the expiration date thereof, the issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any Idnd upon the insurer, Its agents or representatives. 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138�f^�— CTQB Construction Trades Qualifying Board 16,.a BUSINESS CERTIFICATE OF COMPETENCY 15BS00224 RAY FLORIDA ROOFING LLC D.B.A.: TUDUCE MIRCEA B Is certified under the provisions of Chapter 10 of Miami -Dade County ~- usn w�t320 54 ,C LA Y"'�Altf. � M � 7 1�flItl1�R tttLL�f's�",�'-� iLllC:i�10MiE •3 4 SDO opr of �amwNt'"" cptll�s ons«�t to +r�.'ifM'r1�iMx MV..d by W— QUALIFYING TRADE(S) 0044 ROOFING Jaime D. Gaseon. P.E. !...��\ .,r Secretary tithe Board I ..Marridede.90'tKonomY warrrFDode court Y rdairx al prmperty rights fin. Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL. CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 4—,201 q 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: Property Address: 40/ V � /400s'T Roofing Permit Number: Dear Building Official: I Tif^4o-A- certify that I am not required to retrofit the roof to wall connections of my building because: XThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach roof p of ad valorem taxation. o I e b ilding was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 19 4 edition of the South Florida Building Code (1994 SFBC) V" ...... Signature Print Name :.►"` •; SONIA RAMONA TUOUCE State of Florida - . MY COMMISSION # FF954374 County of Dade 'sa�.a EXPIRES Febmary 02. 2020 n(;?Msg5d"53 rwroiimmayServ".core The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of nCT A15 Notary Public, Sate of Florida at Large h, SOMA RAMONA TUD(jCE -�MY COMMISSION # FF954374 Februa.y 02. 2020 When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. with FBC nor a 1994 Revised on 5/21/2009 Ray Florida Roofing, LLC 2180 Nova Village Drive, Davie, FL 33317 1 Phone: 754.246.3100 1561.255.01341 rayfloridaroofing@ymail.com IRC29027485 TAMARA FRANCO MAGALHAES Ray Florida Roofing Rep: 101 NW 100 ST MIAMI SHORES, FL Mitch 5612550134 SL,O:PE 'PILE ROOF CON'T'1._ACT 1. Ray Florida Roofing to tear off existing slope roof down to clean, workable wood deck and replace any rotted wood decking at no additional cost according to requirements of Florida Building Code. Note: Soffit wood, damaged wood from termite not included. See fee schedule for additional charges 2. Ray Florida Roofing to re -nail entire wood slope deck as necessary to meet current Florida Building Code requirements. 3. Ray Florida Roofing to install one (1) layer of # 30 felt over entire slope roof area, as per Florida Building Code requirements. 4. Ray Florida Roofing to install 16" valley metal at all areas necessary as per Florida Building Code requirements. 5. Ray Florida Roofing to install 3x3 26gg galvanized metal drip around complete perimeter of slope roof area and prime for proper adhesion as per Florida Building Code requirements. Galvanized Brown White 6. Ray Florida Roofing to install as necessary new lead flashings at plumbing stacks and slope vents. Note: If wall flashing needs to be removed, may be additional cost for new flashing and stucco work. 7. Ray Florida Roofing to install approved tile underlayment with a uniform mopping of type IV hot asphalt over entire slope roof area. 8. Ray Florida Roofing to back nail tile underlayment to resist slippage, as per Florida Building Code requirements. Page 1 of 3 Ray Florida Roofing, LLC 2180 Nova Village Drive, Davie, FL 333171 Phone: 754.246.3100 1561.255.01341 rayfloridaroofing@ymail.com BC29027485 9. Ray Florida Roofing to install hip and ridge metal for tile installation attachment, as per Florida Building Code requirements. 10. Ray Florida Roofing to install standard flat or roll tile. Standard colors and local deliveries included. Premium colors and shipping extra, if required owner to be notified in writing before. Manufacture Profile roll tile Color 11. Ray Florida Roofing to install tile in medium patty of approved polyfoam adhesive. No nail on application. 12. Ray Florida Roofing to remove all job -related roofing debris from premises. *Note Wood Fee Schedule: (Linear Foot: LF) Two 13v Lumber $5.50/I,F Furrin Strip SLOO/LF One By Decking $5.50/ LF Wood Fascia S6.50/I.,F 5/8" Plvwood Decking $55 per sheet Cedar Fascia S Market Price Special Orders S Market Price *Note: wood charges if any are due upon installation 10 YEAR WORKMANSHIP WARRANTY WITH REQUIRED MAINTENANCE COST: $ Y.2,��.�, PAYMENT TERMS: 1,0% upon signing 40% upon start 40% upon tile load 10% upon completion (Note: credit card payments are accepted and will be assessed a 3.9% fee for each transaction) Page 2 of 3 Ray Florida Roofing, LLC 2180 Nova Village Drive, Davie, FL 333171 Phone: 754.246.3100 1561.255.01341 rayfloridaroofing@ymail.com BC29027485 *Administration and permit running fees are included. *Owner pays for permit cost. Note: Any requirements imposed by building department over and above contract will be additional charge. Gutters, screens, solar heating, air conditioning units, gas vents, etc. must be removed and/or installed by others at owner's expense. Ray Florida Roofing shall not be liable for, without limitation, damage to driveways, sidewalks, lawns, sprinkler systems, gardens, septic systems and drain fields or any other structures as a result of rooftop or on the job deliveries. Ray Florida Roofing assumes no responsibility for damage caused by an act of God or and, act beyond our control. We are fully li sed and insured. This contract is not valid or binding until approved and accepted by an officer of t e c� rporation. Approved By: Print Name: rCIIJYn�-Vc Owner/Agent Accepted By: /1--11 Date: Ap if RV Florida Roofing Representative Page 3 of 3 Property Search Application - Miami -Dade County 10/15/19, 10 46 AM Address Owner Name Subdivision Name Folio SEARCH: 101 nw too st PROPERTY INFORMATION 8 Folio: 11-3101-022-0300 Sub -Division: GOLD CREST SUB Property Address 101 NW 100 ST Owner ALEJANDRO MARTIN CRESPO TAMARA FRANCO MAGALHAES Mailing Address 101 NW 100 ST MIAMI SHORES, FL 33150 PA Primary Zone i 0800 SGL FAMILY-1701-1900 SO Primary Land Use 0802 MULTIFAMILY2-9 UNITS: 2 LIVING UNITS Beds / Baths / Half 41210 Floors 1 Living Units 2 Actual Area 2,316 Sq.Ft Living Area 1,894 Sq.Ft Adjusted Area 2,158 Sq.Ft i Lot Size 9,219.98 Sq.Ft Year Built 1941 Suite µ 4.. 00 Featured Online Tools ..... ,........ .. Comparable Sales Glossary PA Additional Online Tools Property Record Cards Property Search Help Property Taxes Report Discrepancies Report Homestead Fraud Special Taxing Districts and Other Tax Comparison Tax Estimator TRIM Notice Non -Ad valorem Assessments Value Adjustment Board ASSESSMENT INFORMATION 8 Year 2019 2018 2017 Land Value $213,064 $203.054 $203,064 Building Value $255.617 $158.071 $150,057 Extra Feature Value $648 .................................... __..._....... $859 _..................................................._.......... $870 Market Value $469,329 $361,794 $353,791 Assessed Value $469,329 $361,794 $353,791 BENEFITS INFORMATION 8 Benefit Type 2019 2018 Homestead Exemption $25,ODO Second Homestead Exemption $25,000 t Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). https://www.miamidade.gov/Apps/PA/propertysearch/#/ Page 1 of 3 Property Search Application - Miami -Dade County 10/15/19, 10:46 AM TAXABLE VALUE INFORMATION 8 2019 FULL LEGAL DESCRIPTION 9 GOLD CREST PB 21-56 2018 2017 LOT 7 COUNTY E1/2 OF LOT 8 BLK 4 Exemption Value $50,000 $0 $0 LOT SIZE 86.370 X 108 Taxable Value $419,329 $361.794 $353,791 OR 145 02-383 0390 1 r SCHOOL BOARD COC 22858-2862 10 2004 4 Exemption Value $25,000 $0 S0 Taxable Value $444.329 $381,794 $353,791 CITY Exemption Value $50,000 $0 $0 Taxable Value $419,329 $381.794 $353,791� REGIONAL Exemption Value $50.000 $0 $0 Taxable Value $419,329 $361.794 $353,791 SALES INFORMATION 8 Previous Sale Price OR Book -Page Qualification Description Previous Owner 1 Previous Owner 2 0711MO18 $575,000 31075-2259 Qua[ by exam of deed NOMADE REALTY LLC 11/11/2016 $287,700 30320-0286 Financial inst or "In Lieu of Forclosure" stated U S BANK NATIONAL ASSOCIATION TRS C/O OCWEN LOAN SERVICING LLC 06/05/2014 $200,300 29209-4824 Financial inst or "In Lieu of Forclosure" stated EVELYN WRIGHT 10/01/2004 $0 22856-2862 Sales which are disqualified as a result of examination of the dead 03/01/1990 $90,000 14502-0383 Sales which are qualified For more Information about the Department of Revenue's Sales Qualification Codes. 2019 2018 2017 LAND INFORMATION 8 Land Use Muni Zone PA Zone Unit Type Units Calc Valu GENERAL R-14.25, R-15 0800 - SGL FAMILY - 1701-1900 SQ Front Ft. 85.37 $213,06 BUILDING INFORMATION 8 Building Number Sub Area Year Built Actual Sq.Ft. Living Sq.Ft. Adj Sq.Ft. Calc Valu ' 1 1 1941 1,644 1,222 1,484 $190,91 2 1 1941 872 672 672 $64,70 Cy Current Building Sketches Availablel EXTRA FEATURES 9 t Description Year Built Units Calc Valu Chain -link Fence 4-5 fi high 1976 60 $36 Wall -CBS urveinforced F m 1978 120 $28 ADDITIONAL INFORMATION The information listed below is not derived from the Property Appra[sefs Office records. It is provided for convenience and is derived from other government agencies. LAND USE AND RESTRICTIONS .............. . Community Development District: NONE Community Redevelopment Area: NONE iI Empowerment Zone: NONE Enterprise Zone: NONE Urban Development: INSIDE URBAN DEVELOPMENT BOUNDARY Zoning Code: R15 - Existing Land Use: 20 - TWO-FAMILY (DUPLEXES). Government Agencies and Community Services OTHER GOVERNMENTAL JURISDICTIONS https://www.miamidade.gov/Apps/PA/propertysearch/#/ Page 2 of 3 Property Search Application - Miami -Dade County Business Incentives Childrens Trust j Florida Inland Navigation District PA Bulletin Board t r Tax Collector 10/15/19, 10:46 AM City of Miami Shores Environmental Considerations Special Taxing District and Other Non -Ad valorem School Board Assessment South Florida Water Mgmt District The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full di and User Agreement at http://www.miamidade.govfinfoldisclaimer.asp For inquiries and suggestions email us at http:/Avww.miamidade.gov/PAPortaVContactFomVContactFornMain.a3px. Version: 2.0.3 EXEMPTIONS 5 BENEFITS REAL ESTATE TANGIBLE PERSONAL PUBLIC RECORDS ONLINE TOOLS TAX ROLL ADMINISTRAT PROPERTY Deployed Military 40 Yr Building Appealing your Assessment Address Blocking Property Search Appealing your Assessmf Re -Certification Disability Exemptions Assessment Information Change of Name Property Sales Reports Appealing Your Assessment Search Homestead Change of Address Tax Estimator Defective Drywall Exemptions Institutional Change of Ownership & Title Tax Comparison Folio Numbers Extension Requests Senior Citizens Declaration of Condominium Homestead Exemption and Mortgage Fraud Filing Returns Portability More > More > More > More > More > Mc Home Privacy Statement Disclaimer About Us ADA Notice Contact le > ® 2014 Miami -Dade County. All rights reserved. https://www.miamidade.gov/Apps/PA/propertysearch/#/ Page 3 of 3 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) , High -Velocity Hurricane Zone Uniform Permit Application Form I Section A (General Information) I Master Permit No. Process No. Contractor's Name �Q✓/� %.— ��o h,i L, Job Address ROOF CATEGORY • ❑ Low Slope ❑ Mechanically Fastened Tile X Mor?&?A ttesive Set files :....; ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wo4 Sbkrfgles/SbaRas' .9.600 ❑ Prescriptive BUR-RAS 150 • •; • •; • • • : • • • • • ROOF TYPE �• •� •• 0• *000•. ❑ New roof ❑ Repair ❑ Maintenance ❑ Reroofing ❑ ft;Q fering • • • • • • ROOF SYSTEM INFORMATION • • • • • • 0: Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF) ��� • Tb" 7SF) (5A:1 1 1 Section B (Roof Plan) 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 i I_ T .....__........ 1 D 7 Z M a - �' o; . O T I n V -- — - 0 T --- — —_ --- I lJ i i _= -n d!J_ ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form 1 I Section D (Steep Sloped Roof System) Roof System Manufacturer: Notice of Acceptance Number: /I _ D L 1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 11 :. �.; • ...... .... ...... • I \Deck Type:X • I ......_..... Type Underlayment: i 90 • Roo slope: - Insulation: ti,¢ '..' .. ;•••L; 1 Fire Barrier: I Ridge Ventilation? �, Fastener Type & Spacing: ! ow Adhesive Type: I 1 /a7' \ Type Cap Sheet: go C� Mean Roof Height: i Roof Covering: Type & Size Drip SxS A� Edge: 1 1 1 � 1 I I I ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 1 Florida Building Code 6th Edition (2017) 1 High -Velocity Hurricane Zone Uniform Permit Application Form 1 1 Section E (Tile Calculations) 1 For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from M,. If the M, values 1 are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. 1 Method 1 "Moment Based Tile Calculations Per RAS 127" 1 (P1: x 1 = _� - Mg: = Mr, Product Approval M, • (P2: xX Mg: = M2 Product Approval M, : ... 0 • • 1 (P3: xk _ - Mg: = Mr3 Product Approval M, .... 1 Method 2 "Simplified Tile Calculations Per Table Below" • • • • • • • 1 Required Moment of Resistance (Mr) From Table Below 3a • 17 Product Approval M, a_3 0000 • ; • • • •• • 1 1 1 1 1 1 1 ..•... 1 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and 1 Appeals. For Uplift based tile systems use Method 3. Compared the values for Fwith the values for Fr. If the F values are greater than or 1 equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. 1 1 Method 3 "Uplift Based Tile Calculations Per RAS 127" 1 (P1: x L = x w: = _) - W: x cos A = Fr, Product Approval F' (P2: x L = x w: = _) - W: x cos 0 = F2 Product Approval F 1 (P3: x L = x w: = _) - W: x cos 0 = Fri Product Approval F 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Mr required Moment Resistance" 000000 • Mean Roof Height Roof Slope 15' 20' 25' 30' • • • • • • 40' • • • • • 2:12 34.4 36.5 38.2 39.7 • 42.2 ; • • 3:12 32.2 34.4 36.0 37.4 • 39.8 4:12 30.4 32.2 33.8 35.1 37.3'.; 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity Ma Product Approval ' Attachment Resistance M, Product Approval Required Moment Resistance M9 Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width . Product Approval All calculations must be submitted to the building official at the time of permit application. SECTION HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR R ROOFING 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contrcictor tp provic�'�� owner wilh • • • the required roofing permit, and to explain to the owner the content of the section. T�e'prbvisior s cif• Iwne w*, p. govern the minimum requirements and standards of the industry for roofing systerr►ir2elal#etions. Adei?io tionally, 44 ••' following item should be addressed as part of the agreement between the owner 8nrtt 'contractor' The owrvs• •: initial in the ignated space indicates that the item has been explained. 2. Renailing wood decks: When replacing roofing, the existin�oc�d►roof deck •nay have to'.• be renailed in accordance with the current provisions of Section R4403. ( e roof deck 1S.uStL�{ly •.••.• cor�aled prior to removing the existing roof system). • . •••••• sees 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofin nail penetration of the underside of the decking may not be acceptable. This provides the option of mai a ning the appearance. 6 verflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow / scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. "Owner/AgentV'sSignatureDate Co a ctor Signature Date AP/ Aso " p- Property Address Permit Number Revised on 7/9/2009 LD;07/01/2015; MIAMI-UADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Boral Roofing, LLC :...:. 7575 Irvine Center Drive, Suite 100 • Irvine, CA 92618 •••••• ••.• ...... COPE: • • •. .. ...... This NOA is being issued under the applicable rules and regulations governing the use of cortsMuction materials. Tie: documentation submitted has been reviewed and accepted by Miami -Dade County RER - Px.Qd..u..pt. • • 00900 Contt9L Spgtion tp.l q used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdirtiola4AHJ). . • .: This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count� Product Con�iol'Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to baye ibis • product or material tested for quality assurance purposes. If this product or material fails to perform in tale Alcepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.18-0509.15 and consists of pages 1 through 7 The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufactured Bor�IR66fing ".. in Lake Wales, FL and described this Notice of Acceptance. For locations where Na prossurer eqv r�ements, as determined by applicable Building Code, do not exceed the design pressure values gained byoealtulationg In • • compliance with RAS 127 using the values listed in the installation section herein. 'T1ti IAtachmed calcula£aoas.: shall be done as a moment based system. ."". •. .... . .. ..... 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Barcelona 900 Length = 17" Width = 13" 'h" thick ...... . . ..... .. .. .. .. ...... Test : Ptrocduct . . ...... Specifications Description:*"" 0 • • • • • TAS 112 High profile, interlocking, ones;j*g;'S' shaped, Type — la high-pressure extruded concrete roof tile equipped with three nail holes. For direct deck or battened nail -on, mechanically fastened, mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete Width: varies roof pieces for use at hips, rakes, ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BONDTM Roof Tile Adhesive DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam Inc. NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Qec. 1991 Appendix III TAS 102 & TAS 102(A) ;••••• ,.,,,, Redland Technologies 7161-03 Wind Tunnel Testing ."*sec. 1991 'o Appendix II TAS 108(NjC-***) Redland Technologies P0402 Withdrawal M ce R St'ali • • ""' $e�pt. 1993 Testing of screw W 9mooth` , of•': • •. .goof. shank ngils,�• . . f.... •��•�� Redland Technologies Letter Dated Aug. 1, Wind TunnetTt:?i¢g ������ *Aug. 1994 •, 1994 TAS 108 (N'ai 1-Oit) :... % ...... Redland Technologies P0631-01 Wind Tunne;Testixg 19446"s TAS 108 (Mortar Set) ..July • • • • Professional Service Industries, Inc. IC-1320-94 Physical Properties Feb. 1995 TAS 112 The Center for Applied Engineering, Inc. 25-7688-3 TAS 101 (Adhesive Set) June 1996 25-7688-10 TAS 101 (Mortar Set) July 1996 The Center for Applied Engineering, Inc. 25-7688-5 Static Uplift Testing June 1996 TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) The Center for Applied Engineering, Inc. 25-7688-4 Static Uplift Testing June 1996 TAS 102 (4" Headlap, Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier 09/01/16 Walker Engineering, Inc. Evaluation Restoring Moments Due to 09/01/16 Calculations Gravity American Test Lab of South Florida RT0617.03-16 TAS 112 06/29/16 PRI Construction Materials Technologies COPO-002-02-10 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-02 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-01 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) C•DADEOU CNOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 3 of 7 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may require, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Department of Regulatory and Economic Development — Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slopiUnligs stated.... otherwise by the underlayment material manufacturers published literature. • • • • • • .' 3.6 This acceptance is for wood deck applications. Minimum deck requirements sh'A17IV?h cor 1plt tf a witlr ... • applicable building code. 000000 • .... .. . .... . .. ..... .. .. .. .. ...... 4. INSTALLATION • 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict g%ripliance with Roofing.: .. . . .. : Application Standard RAS 118, RAS 119, and RAS 120. :..• 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length -I (ft.) 1 Width-w (ft.) Barcelona 900 • 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity - M9 (ft.-lbf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct I Deck Battens Direct Deck Battens Direct Deck 6.19 7.07 6.19 7.00 6.19 6.90 1 6.06 1 6.76 5.92 6.60 5.76 6.42 NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank 5.1 6.8 2.8 Nail 2-10d Smooth or Screw Shank 6.9 : 9.2'. 7.3 .... Nails •••• 1 #8 Screw 20.7 .20:7. 18.1 2 #8 Screw 43.2 4&2 . 29.8 : *'0 1-10d Smooth or Screw Shank 23.1 25:1 1 • • 19.0 • • • • Nail Field Clip).... ...... . 1-10d Smooth or Screw Shank 29.3 �Q 024.0 • • • • Nail Eave Clip) •04 2-10d Smooth or Screw Shank 27.6 : 27.6 ""*38.6. , Nails Field Clip)• • .. • • • • • • , 2-10d Smooth or Screw Shank 38.1 38.1 •' • • 41.8 Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4" the headlap and fasteners are located a min. of 2'/2" from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive' Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Tile BondTA°One Component Roof Tile Adhesive 29.32 ICP Adhesives Polyset® AH-160 two -component foam 29.33 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive 664 1 See manufactures component approval for installation requirements. 2 TILE BONDW Roof Tile Adhesive; Average weight per paddy 10.7 grams. 3 ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160; Average weight per paddy 8 grams. 4 DAP Foam Touch N Seal StormBond® Roof Tile Adhesive Two -Component; Avera a weight per paddy 8 grams. APPROVED NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment - Mr (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 ICP Adhesives Polyset® AH-160 two -component foam 66.55 ICP Adhesives Polyset® AH-160 two -component foam 38.7 6 DAP Foam Touch N Seal Storml3ond® 2 63 7 DAP Foam Touch N Seal Storml3ond®2 ; �•• $7°" ..,,, 5 Large paddy placement of 63 grams .' • • •, • 6 Medium paddy placement of 24 grams • • • • • 7 Medium paddy placement of 30 grams .....' 8 Large paddy placement of 60 grams • Table 8: Attachment Resistance Expressed as a Moment - M?(ftmbf) • • • • • •... �....� �• for Mortar Set Systems . . Tile Tile ,•, Attac ment Profile Application RegisMce • Barcelona 900 Mortar Set9 24.5 9 Seespecific mortar manufacturers Notice of Acce tance 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". W LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 6 of 7 NAIL HOLES r 17" NZ PROFILE DRAWING OVERLOCK 13" UNDERLOCK BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE •••••• • •••••• •k„t • .••••• • •.0•••• 0009 • Y 69 00006 •• •• •••••• •• ...... ...... •••• NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 7 of 7 MIAMI-DADE COUNTY MIAMI PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 • • • ...... .... ...... SCOPE: •••:•• :....: This NOA is being issued under the applicable rules and regulations governing the use of t6fittructioc materials. The, • documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to.&.' used in Miami Dade County and other areas where allowed by the Authority Having Jurisdi..c.ji.v.nCAHJ).. .' .: • • • • • • This NOA shall not be valid after the expiration date stated below. The Miami -Dade CoAV Vroduct .Control Sectic, i :. (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to h:t48'thts prod ct0 00 or material tested for quality assurance purposes. If this product or material fails to performe4uthaaccepted"inner,•the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polysete' AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as cl'escribed• • ; • in this Notice of Acceptance. For the locations where the design pressure requirements, as leierniined IV lLpplicable '. building code, do not exceed the design pressure values obtained by calculations in compliancq with RoCI MA • • • • Application Standard RAS 127. For use with approved flat, low, and high profile roof tile 9�§Mlfs usingIq�P ; • • • •; Adhesives Polyset® AH-160. • • • • ...... . . ..... PRODUCTS MANUFACTURED BY APPLICANT: • • • • • • • • • • • "":' Product Dimensions Test Product Ws Tription • • • • • Specifications • ICP Adhesives N/A TAS 101 Two component polyurefhane t9;6*ndhesive • PolyseeAH-160 ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft' 3.1 Perm / Inch +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Center for Applied Engineering #94-060 257818-IPA 25-743 8-3 25-7438-4 25-7438-7 25-7492 Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services NB-589-631 9637-92 01-6743-011 01-6739-062b[ 1 ] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Renort TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 .'. SSTD 11-93 ASTM D 1623 .... ASTM E 108 • • " ASTM E 108 ASTM E 84 • ..' TAS 114 ASTM D 1623 TAS 101 TAS 123 TAS 101 TAS 101 TAS 101 Date 04/08/94 12/ 16/96 10/25/95 •....• �I1/0;/95 •1,?/j 95 U2/04/94 trrrs�94 01 /1095 •..• 03/14/96 04/ 18/ 12 02/21/12 10/23/98 12/28/98 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI•DADE CNOA No.: 17-0322.03 OUNTY ... I Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the "seance value determined in compliance with Miami -Dade County Roofing Application Standards "127. The ad esive 0*00 •• .. . •11• attachment data is noted in the roof tile assembly NOA. ...... ....• .....• . 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance "ithRoofing Application....: Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and WAtenance Vooklet. • 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed k�4I+GP Adhesive; and • • • • • • Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicateorseto the auftrhy havifit jurisdiction. • • • • • • • 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required bef3re applicatiQ�••�; of any adhesive. The mix ratio between the "A" component and the "B" component sflaU bc•maintiged &tween • 1.0-1.15 (A): 1.0 (B). of** 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at . overlap ..... . .'. Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal .. ";17 grams, p ea .. edge) 20-25 sq. inches each 0•0" bead '• • .... Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches ge ... •,� grarrbs und$r pan,,*-: LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of tho%. 0 manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE CONOA No.: 17-0322.03 "' • UNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 tttOUgtthRlarticcuft t r+adklyf2tanQathTiia} lwlsm fftdradl ton. Eays cwnaasdo �a ti Nail throuighplas* rtmern (when required) Paddy iltrm.ath Ti1sl urtdlayntaxrt /4in.x 2 in wtdis + ltattemolNiorwall 1 AV ° «««.IawCla�sura Cave count �— iasNa Nailihr+n��pl.►Hcc a"„ C"on roquite+dt PA ddy IBonwalkTilol ,v i 2 in, wide ��� hatta�as Er ira tours* �na3 lYberyhole loin, in. - Esre-clasur m Ulitte MIAMI•DADE COUNTY ,...� t . Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pap tije • • . 1. Starting at the eave courses apply a mt>limum•• 2 ...... (50.8 mm) x 10" (254 mtil�j x• � 13 (25.4 xrltt>�l foam * : •' • paddy onto the underlaytht?4 tpsitioned as shown • � - • under the pan portion of the tO closCitlQl he ....% overlock of the tile being S>rt • • 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as$ho-vyn under tko:. strengthening rib closest to Tko overlock gt& tile ..• being set. •••••. • �7j PP kiT Y 4..... Continue in same manner. >;nsur>s.a ro i atel 10. (64.5 cm2) - 12(77.4 cm2) $Zj;r inch AdhVive • •... contact with the underside; fiL;'tile. • :. : • • • • • .. .. ...... ..... ...... Medium Profile / Double Pad TM • . 1. Starting at the eave course, apply a mint$itIn 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 IIAMI•D DDE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Mali tluauolh 01ank to twhenrequired) Pitj&rfs#r vtthTile) tAn�i+r#»�rrt Tin* Uatteas eptioul ti E•veCoutrse �.•, �asria t` tYwepi�akY roar. ate. [•�tcieste .:�" oripedpe MIAMNDADE COUNTY ...s r. High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the the closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 Vim) foam piddyWto the underlayment positioned as %ptvrr under th a pan • • • • • portion of the tile closest to 4k@ ewerlocle9 f 14o tile • ...... being set. ...... • 3. Continue in same manner. Insu'rd approximately 17". z f • • • . • (109.7 cm) - 19 (122.6 cm.),xqua!re incll'adh¢ive •••.. contact with the underside of 4bg file. •' • • • • • • . ...... ...... NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Hall through plastic cement Paddy (between tiles) (when required) Battens optional • Paddy iunder tile) Single paddy an top aitile r r.i 1 ►1 X d in. `` �`•� �Y� 4, up r til Singlepaddy all underlaymen Z X s ina y `' 1OinLL�°-,f 4'2 in ut ,. Eave ttosure Flat/Low Profile Tile Nail through plastic cement Single paddy under tile {when m"Ired) IN ibe2rveen ties) Battens paddy (under t1e) opt.w `may singlepad� ontopoftile` t .� Spa X a in. 2 x d in. ' 4� unotdayment 0 in ` w' 2 In. Eave Closure Eave Course Fascia Medium ProflleTlie CMIAMI-D�ADE COUNTY 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1 " (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the Overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in (109.7-148.4 cm2) of adhesive contact with the underside of the tile • • ••...• 000000 2. Apply a 4" (101.6 mm) yJ0 jldl.6 rnrtSJk'1" (25.4 •� mm) foam paddy onto the�Grlayment lust below • • • the second course line positioned foaig paddy • •...: under the strengthening rib*roflat tire, brAder d w pan portion of the tile, crosk9f to the ptiderlock far•;. • • the second course tile tootle installed. YAs4e •..... approximately 8-9 in 6000 (ft1.6l5$.1 cm2) of adhesive • contact with the underside otthe till ... • • • • •. • • • • • • • • • •••• (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Hail through plastic Sir►gle paddy under the when requited) Paddytbetrreen tiles) Battens optional Paddy (under Met em 1%41n.'`�,� 2x4)n. Paddy on top of toe-- Eave Course ascia Weeghole 10 in.2 in. Eave closure Drip edge High ProflleTiie 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 1/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cmZ) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • •••••• •••••• ...... ....•. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL t) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications in contact with the pan tile. when required) 2) Turn covers upside down. Place adhesive in to t in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. Underlayment 1 ° o / �� ' �r'' ice' f;� ♦y ° Sheathing Eave dosur ' (motar shown) weephole Fascia Board Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure rave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (41.9.4 c�riZ) — 70(�451•.6 cm. • • • • square inch adhesive•coAaCt with Ur. underside •• of the pan tile. ••••.. .... • . • • • . • 3. Turn covers upside dvWi14posirV l;bC underside • of the tile. Apply a minimum 1" (25.'� mm) x'ItC * •. 00*00 (254 mm) bead of ad ;sive�directly�uq Jehe inn,j; � • • edge of each side of Ow wyer tile. Leave • • approximately 3/4" (:9 ttIA) to 1: (25.4 mm)•...:. from the outside edgC of�hp tile, mward, free of • foam to allow for expAdsiod. • • *as• •e. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cmZ) - 25 (161.3 cm') square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES —UNIFORM PERMIT APPLICATION Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,y� • Prescriptive BUR-RAS 150 A,B,C 4,5 6�3 .'• Asphaltic Shingles A,B,D 1,2,4,C46,S-- Concrete or Clay Tile A,B,D Metal Roofs 1,2,3,4,CDv&W- Wood Shingles and Shakes A,B,D 1,2,4* ,6,Y Other As Applicable 1,2,3,4,5,C,7: -- • • -- ATTACHMENTS REQUIRED: ' • 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation