Loading...
RF-19-2011Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 N-eTt M,- Hi Issue Date: 09/11/2019 Location Address Parcel Number 170 NW 92ND ST, Miami Shores, FL 33150 1131010000231 Contacts Permit No.: RF-08-19-2011 Permit Type, Roof Work Classificotron Tile Permit Status: Approved Expiration: 03/09/2020 LARRY ANDERSON Owner 170 NW 92 ST, MIAMI SHORES, FL 33150 TRADE PRODUCTIONS INC Contractor THOMAS DRYER Business: 9548221943 Description: TILE RE -ROOF Valuation: $ 18,500.00 Inspection Requests: 305-762-4949 Total Scl Feet: 2,821.00 Fees Amount Application Fee - Other $50.00 CCF $11.40 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $3.80 Roofing Fee $250.00 Scanning Fee $12.00 Technology Fee $7.50 Total: $342.20 Payments Date Paid Amt Paid Total Fees $342.20 Credit Card 09/11/2019 $292.20 Check # 2542 08/29/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AF VI i � that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating-contr c�io 0 i g. thermore, I authorize the above named contractor to do the work stated. 9 ill l Authoriz Signature: Owner F / Applicant / Contractor / Agent Date September 11, 2019 Page 2 of 2 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC Miami Shores Village RECEIVED Building Department YBY: 12019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 'LL_ Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949F Master Permit No. � ` v 20 ROOFING Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP l CONTRACTOR DRAWINGS JOB ADDRESS: IV 1 `� �J"�� l vMT6 a� Om 1 _�;u "'nl 5o G Citv: Miami Shores County: Miami Dade Zip: I c Folio/Parcel#: I PCIDI V I—vW— 00 _Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FIFE: OWNER: Name (Fee Simple Titleholder): Address: �� Nu 2 City: VA` M \ Tenant/Lessee Name: Email: CONTRACTOR: Company Name: Address: -�� 2I LI h) LQ City: Qualifier Name: State Certification or Registration #: jr� DESIGNER: Architect/Engineer: 11. 9_ hone#: m W_ P43 te: %c Zip: Phone#: C Certificate of Competency #: ne#: Address: City: State: Zip: Value of Work for this Permit: $ f ��r� — Square/Linear F :Rte age of Work: Type of Work: ❑ Additi ❑ Alt tion ❑ New pair/Replace ❑ Demolition Description of Work:. 0— Q Specify color of color thru tile: a Y1 Submittal Fee $ �� Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) CCF $ CO/CC $ DBPR $ Notary $ Double Fee -$ _ Bond $ � TOTAL FEE NOW DUE $ !9_ GI 2 . 2 O ::!'(( 2 -2j:::5 F 'Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of com m,Ppcement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. n he absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. <0111Z Signature Sig/ure*M& WNER or AGENT CO The foregoing instrument was acknowledged before me this Th %foregoing instr ent was cknowledged befor a this �� day of U 20 _I Q by /Z day of 20 by Yftcjhog1is personally known to jwho is personally known to me or who has produced 1�� `'' as me or who has produced R U/ as identification a d ho did take an o h. NOTARYPU Sign:(�'Print� A i►x� ARIANNA GARCIA ° Seal: Notary � .a, • < ry Public -State of Florida Commission x GG 324911 OF M y Comm. Expires P Apr 17. 2023 ,.: Bonded through ational Notary Assn. ************ * APPROVED BY identification and who did take an oath. NOTARY PUBLIC: Sign: la I Print: Seal: �yr'aI9e:, CASEY HUTSON ?:° • Notary Public - State of Florida Commission I GG 301829 Bonded through National Notary Assn. Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Property Search Application - Miami -Dade County Page 1 of I OFFICE OF T111,1111111E Po"PERTY APPRAISER HU Summary Report Property Information Folio: 11-3101-000-0231 Property Address: 170 NW 92 ST Miami Shores, FL 33150-2229 Owner LARRY G ANDERSON Mailing Address 170 NW 92 ST MIAMI SHORES, FL 33150-2229 PA Primary Zone 0800 SGL FAMILY - 1701-1900 SO Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 2,365 Sq.Ft Living Area 1,788 Sq.Ft Adjusted Area 2,157 Sq.Ft Lot Size 7,680 Sq.Ft Year Built 2003 Assessment Information Year 2019 2018 2017 J$151,937 Land Value $159,593 $151,937 Building Value $229,181 $231,878 $217,684 XF Value $3,304 $3,343 $3,382 Market Value $392,078 $387,158 $373,003 Assessed Value $297,757 $292,206 $286,196 Benefits Information Benefit Type 2019 2018 2017 Save Our Homes Cap Assessment Reduction $94,321 $94,952 $86,807 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000, $25,000 $25,000 Senior Homestead Exemption $50,000 $50,000 $50,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 1 53 41 .177 AC W1/2 OF E153.6FT OF W288.6FT OF S1/2 OF SW1/4 OF NW1/4 OF SE1/4 LESS S198.87FT THEREOF & LESS N37.50FT FOR R/W Generated On : 8/29/2019 Taxable Value Information 2019 2018 2017 County Exemption Value $100,000 $100,000 $100,000 Taxable Value 1 $197,757 $192,206 $186,196 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $272,757 $267,206 $261,196 City Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $247,757 $242,206 $236,196 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $247,757 $242,206 $236.196 Sales Information Previous OR Book Price Qualification Description Sale Page Deeds that include more than one 02/01/2002 $239,000 20235-2395 parcel Deeds that include more than one 12/01/2001 $77,000 20073-4276 parcel The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer. asp https://www8.miamidade.gov/Apps/PA/propertysearch/ 8/29/2019 RICK SCOTT GOVERNOR JONATHAN ZACHEM, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSI:NG BOARD THE ROOFING CONTRACTOR HEREIN IS CERTIFIED UNDER THE PROVISIONS OF CHAPTER 489, FLORIDA STATUTES DYER, THOMAS JAMBES TRADE PRODUCT[O'NS INC '5501'SW'163. AVE S-O.UTNWEST RANCOES FL 33,331 LICENSE NUMBER: CCC1328241 EXPIRATION DATE: AUGUST 31' 2020 Always verify licenses online at MyFloridal-icense.com Do. not alter this. document in, any form. This is your license. it is unlawfulJor anyone other than it -he licensee to use this document. BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-8314000 VALID OCTOBER 1, 2018 THROUGH SEPTEMBER 30, 2019 DBA: Business Name: TRADE PRODUCTIONS INC Owner Name: THOMAS J. DYER Business Location: 5501 SW 163RD DAVIE Business Phone: 954-822-1943 Receipt#:ROOFING/SHEET METAL CONTRACTOR Business Type: (CERTIFIED ROOFING CONTRACTOR) Business Opened:10/06/2010 State/County/Cert/Reg:CCC13 2 8241 Exemption Code: Rooms Seats Employees Machines Professionals 3 For Vending Bustneas Only Numhwr of Machtnwwc Tax Amount Transfer Fee NSF Fee Penalty .- .11 Prior Years . Collection Cost Total Paid 27.00 0.00 0.00 2.70 0.00 1 0.00 29.70 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: THOMAS J. DYER Receipt #52A-18-00000289 5501 SW 163RD DAVIE, FL 33331 Paid 10/09/2018 29.70 i 2018 - 2019 ACORN►® CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDryYYY) 8/22/2019 PHIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER BB Insurance Marketing Inc 10167 W Sunrise Blvd 3rd Floor NAME: CONTACT Certificate Department PHONE FAX • 888-728-0817 Ext 312 AIC No): 954 452-0450 ADDRESS: certificates@bbimi.com INSURE S AFFORDING COVERAGE NAICU Plantation FL 33322 INSURER A: Brid efield Casualty Ins Co 10335 INSURED TRADPRO-01 INSURER B : Lloyds of London Trade Productions, Inc. 5501 SW 163 Ave INSURER C INSURER D: Southwest Ranches FL 33331 INSURER E : INSURER F : COVERAGES CERTIFICATE NUMBER: 1349990671 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL SUER POLICY NUMBER MOLICYEFF /YYYY POLICY M/L UY� LIMITS B X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE EKOCCUR WCIS-CGL-0002557-01 12/20/2018 12/202019 EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED PREMISES Ea occurrence $100.000 MED EXP (Any one person) $ 5,000 PERSONAL & ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: X POLICY JE � LOC OTHER: GENERAL AGGREGATE $ 2,000.000 PRODUCTS -COMP/OP AGG $ 2,000,000 $ AUTOMOBILE LIABILITY ANY AUTO ALL OWNED SCHEDULED AUTOS AUTOS NON --OWNED HIREDAUTOS AUTOS COMBINED INGLE LIMIT Ea accidentS $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE Per accident $ UMBRELLA LIAB EXCESS LIAR OCCUR EACH OCCURRENCE $ HCLAIMS-MADE AGGREGATE $ DED RETENTION $ $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below A NIA 0196 45048 12212018 12212019 X I STATUTE I EERH E.L. EACH ACCIDENT $ 1,000,000 E.L. DISEASE - EA EMPLOYE $ 1,000,000 E.L. DISEASE - POLICY LIMIT I $ 1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached B more space is required) Roofing Contractor CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Village of Miami Shores 10050 Ne 2nd Ave AUTHORIZED REPRESENTATIVE Miami Shores FL 33138 ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25 (2014/01) The ACORD name and logo are registered marks of ACORD Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Master Permit Number Process Number Contractor's Name Job Address •....' � �. • ...... ROOF CATEGORY �• .".'. •. ...... .. ❑ Low Slope ❑ Mechanically Fastened Tile kmo rta F/AJvmive Set Tit. ...... ❑ Asphalt Shingles ❑ Metal Panels/Shingles ❑ Wood`j6V*files/Shakes•. ' Is there an existing Roof Top Solar System? (' Yes No Will it be reinstalled?:e fifes .. .. .... ...... Are there as vents on the roof? g i Yes No Type. ❑ Natu(al� LPGX • ROOF TYPE • ❑ New Roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering •"' ROOF SYSTEM ROOF INFORMATION Low Slope Roof Area (ftZ) Steep Slope Roof Area (ftZ) ��_ Total (ft)_�_ Section B (Roof Plan) Sketch the Roof Plan: Illustrate all levels and sections, roof drain, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and locations of parapets. . RECEIVE AU 2 9 219 BY. 4ac�� �� �- I Miami Shores Villige APPROVED BY DATE ZONING DEPT RLDG DFPT i,lti, ;. c C ('.,'' IAW-r VATI I N I FI I;" HN I. i 123 01-48 4/19 PAGE 2 ea levi W,M AREA DIAGRAM Total Area = 2,821 sq ft, with 8 facets. Premium Report 5/ 14/2019 ••.••. •••••• S Note: This diagram shows the square feet of each roof facet (rounded to the nearest Foot). The total area in square feet, at the top of this page, is based on the non -rounded values of each roof facet (rounded to the nearest square foot after being totaled). 2008-2019 Eagle View Technologies, Inc. and Pictometry International Corp. — All fights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. other Patents Pending, PAGE 6 Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations: P 1: P2: P3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge/Thickness: Slope: Anchor/Base Sheet & No. of Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s) & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet AttachgVpt . . .... ...... Field: " oc @ Lap, # Rows of • • Perimeter: " oc @ Lap, # R(",%" @ oc """ ...... Corner: " oc @ Lap, # Row9 .... @ :' CC '. • • .. Number of Fasteners Per Insulatiora Baird:00 � • • • • • • Field Perimeter : • •; •; Corner• . • • • .......... Illustrate Components Noted anyj Details as Applica.%: . • Woodblocking, Gutter, Edge TerrAilhation, Strippinj.Flashing*'•'; Continuous Cleat, Cant Strip, Base Flashing, Cgtngeflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. 123 01-48 4/19 PAGE 3 Florida Building Code 6th Edition (2017) 1 High -Velocity Hurricane Zone Uniform Permit Application Form 1 1 Section D (Steep Sloped Roof System) 1 1 1 Roof System Manufacturer: n C 4 \ i� 1 Notice of Acceptance Number: Ni 0<6 . d 1 Minimum Design Wind Pressure If Applicable (From RAS 27 or Calculations): • •.. 1 P1: P1: P1: C) • ••� �....' •i...• Deck Type: • . ..'. .... .. ..L.. Type Underlayment: r,/` a� �� •� "" Act ��•� .. r ... Roof Slope: - — 12 Insulation: _� 1 . �•� Fire Barrier: 1 1 Ridge Ventilation? Fastener Type & Spacing: e3 4 Mal 1 1 Adhesive Type: `. 1 1 Type Cap Sheet: 1 1 Mean Roof Height: Roof Covering: Can 1 - 1 Type & Size Drip 3 1 Edge: 1 1 1 123 01-48 4/19 PAGE 4 f)L.rL a. 16 mac, ` Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from M,. If the M, values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Metho 1 ' oment Based Tile Calculations Per RAS 127" 1 x _ - Mg:& •it 0 = Mr1 Product Approval M, `Sg •7 (P2:� xX �3a1='�%C�j - Mg: �10 = Mr2 Product Approval Mf �.... (P3:W xX r� _ ` 3I) - Mg: 4 �+C = Mr3 2LK ( Product Approval M, • �. "" • • • Method 2 "Simplified Tile Calculations Per Table Below" 699069 Required Moment of Resistance (Mr) From Table Below Product Approval Mf * 0 0 0 00 0 Mr required Moment Resistance` 0000 Mean Roof Height Roof Slope 15' 20' 25' 30' . • 040' • 2:12 34.4 36.5 38.2 39.7 • . f12.2 3:12 32.2 34.4 36.0 37.4 39.8 •. 4:12 30.4 32.2 33.8 35.1 .437.3 5:12 28.4 30.1 31.6 32.8 34.9 • 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 "Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1: x L = x w: _ ) - W: x cos 0 = Fri Product Approval F (P2: x L = x w: _ ) - W: x cos 0 = Fr2 Product Approval F (P3: x L = x w: _ ) - W: x cos 0 = Fri Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier x Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance M9 Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 123 01-48 4/19 PAGE 5 OR ` �"" SL'4 Miami shores Village 'yell "loom Building Department 10050 N.E.2nd Avenue ��oRIDp' Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax:4X)5) 756,8972 OWNERS'S AFFIDAVIT OF EXEMPTION:::-* ••••�• ..1: • • ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING $IJE•• : • • • • BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES;;;;• ; ;; ;00;0. PERSUANT TO SECTION 553.844 F.S. •' 00000 ••• • • • • • • • • : 40 I ....:. To: Miami Shores Village Building Department pkty �• ; • • • • 10050 NE 2nd Ave • Miami Shores, Fl 33138 Re: Owner's Name: Property Roofing Permit Number: Dear Building Official: I `a certify that I am not required to retrofit the roof to wall connections of my bui ing because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00, Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Luau �le��c,n Signature Print Name ,Ay a '"••. ARIANNA GARCIA _° •': Notary Public • State of Florida Commission b GG 3249t 1 State of Florida f a ti My Comm. Expires Aar 17, 2023 County of Dade Bonded through Nationa, Notary Assn. IF The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this y of Notary Public, Sate of Florida at Large When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300.000 00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 8/21 /2019 Property Search Application - Miami -Dade County ASSESSMENT INFORMATION Year Land Value Building Value Extra Feature Value Market Value Assessed Value TAXABLE VALUE INFORMATION COUNTY Exemption Value Taxable Value SCHOOLBOARD Exemption Value Taxable Value CITY Exemption Value Taxable Value REGIONAL Exemption Value Taxable Value https://www8.miamidade.gov/Apps/PA/propertysearch/#/ 2019 $159,593 $229,181 $3,304 $392,078 2018 $151,937 $231,878 $3,343 $387,158 2017 $151,937 $217,684 $3,382 $373,003 $292,206 $286,196 01 2019 2018 2017 $100,000 $100,000 $100,000 $197,757 $192,206 $186,196 $25,000 $25,000 $25,000 $272,757 $267,206 $261,196 $50,000 $50,000 $50,000 $247,757 $242,206 $236,196 • •• • • • • ••• • $50,000 • • • • • • @WPOOD • • $50,000 $247,757 • • • • • • 1242,206 • $236,196 ••• • • • • ••• • • ••• • • • ••• • • 4/11 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR RQUING CONSIDERATIONS • . .. .... ...... 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor .R,r4Yi a the ownerwith tP� • ••••:• the required roofing permit, and to explain to the owner the content of the section. The prpVr$ pns of S,*tio*q R4402: • •..: govern the minimum requirements and standards of the industry for roofing system instdllatipAS. Addi:or%a ,Othe following items should be addressed as part of the agreement between the owner ant tha *Wractor. the owner's ••��•' • initial in the designated space indicates that the item has been explained. ' ' • .. .. .... . �; • .. ...... • 2• Renailing wood decks: When replacing roofing, the existing wood 144deck r$ay have to ...0 % be renailed in accordance with the current rovisions of Section R4403. The rooldeck is us; aB p �.��•; • concealed prior to removing the existing roof system). " ' 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. -42 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or r roof extension may block this discharge if overflow scuppers (wall outlets) are not provioTynay be necessary to install overflow scuppers in accordance with the requirements of Secjie6s V402, R4403 and R4413. wo-"� C. wnerl b'ds Signature Date 1-:�o My MM.5�- Property Address �� � � O VAkUM FL Revised on 7/9/2009 LD;07101/2015; Permit Number MIAMI-DADE COUNTY Ml© PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 441' Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County VfQduct NftttUl Secti"r • • • (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to haJe*WSs product • or material tested for quality assurance purposes. If this product or material fails to perform,it,tee accepted manner, manufacturer will incur the expense of such testing and the AHJ may immediately revoke, vpAfy, or jgspe.nd the V*90 of such product or material within their jurisdiction. RER reserves the right to revoke. tbit acc4)tSUce, if its determined by Miami -Dade County Product Control Section that this product or material faii9"meet tpe requiremej4$, . • of the applicable building code. • • • • •• • • • • •... This product is approved as described herein, and has been designed to comply with the• Fiorida.Building including the High Velocity Hurricane Zone of the Florida Building Code. . ; • • • • DESCRIPTION: ICP Adhesives Polyset® AH-160 Code'. .... • . LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. MIAMMDADE COUNTY NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: .... Product Dimensions Test Product&hiption*�'� Specifications ...•.• •••••• ••�•�• ICP Adhesives N/A TAS 101 Two component pow Tflane foari! adhesijg••.; Polyset®AH-160 -i .... .. • .... . .. *ere ICP Adhesives Foam N/A Dispensing Equipment. .. - : . .. • •; � • Dispenser RTF1000 • • • • • • .. ...... ICP Adhesives ProPack® N/A Dispensing Equipment ' • • • • 30 & 100 •• • • •••••• PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ftz 3.1 Perm / Inch +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @I58°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94-060 257818-1 PA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[ 1 ] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 ASTM D 1623 ASTM E 108 ASTM E 108 ' ASTM E 84 • •: •' TAS 114 '��.•• ASTM D 1623 ...... TAS 101 •••••• TAS 123 •••••• TAS 101 .'. TAS 101 TAS 101 Date 04/08/94 12/ 16/96 10/25/95 11 /02/95 12/12/95 02/01/94 043W3 ' .... Ll'/'1 ¢f9.4 0 to 6795 �1/614796 Q4/ W 12 e�z�v�2 1 0/23/98 12/28/98 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset' AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at •... overlap • 0040 .00 Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal • . �.17 graWw`bead ... edge) 20-25 sq. inches each • • • • • . . bead ••• •• • • 0 Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 9•34 grams under pan..; .. .. .... ...... LABELING: • • • • • • All approved products listed herein shall be labeled and shall bear the imprint or identifiable rharking of tie. • •. • manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" oY*W Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 INSTALLATION: 1. ICP Adhesives Polyset AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset AH-160. 2. ICP Adhesives Polyset' AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authoiiiy having jurisdiction. ••� •... ...... 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is rPauu�ji befor 09 0ppkcatio 000000 of any adhesive. The mix ratio between the "A" component and the "B" component sbpjtop jnaintaine� betweeg • 1.0-1.15 (A): 1.0 (B). ..•. :0 . :••••• 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser W17 1000 of ICP• 69:96 Adhesives ProPack' 30 & 100 dispensing equipment only. .. .. .... ...... 7. ICP Adhesives Polyset' AH-160 shall not be exposed permanently to sunlight. • • • 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minu s after ICP Or&v66ives •"•� Polyset® AH-160 has been dispensed. •.. • : • • • •.. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with t;e • • 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 ADHESIVE PLACEMENT DETAIL # I man through plasilccwnont PaddyISonamItiie) 1wlun toqulrodi•`� Urxlrrl+ymstna N,- 4 . A" lla:tansoptional ,�:' ' •. �� � j'f' f Fascia Nail through pias* cemersr (when required) P•ddy4Bwn.wth T&I vndwldynernr 10 in. Battens opglomal •w�` •+ 4„�Y' r'''�,•� �.'�'w"`":6_ ,. � ��tE1 Sri •-,•� �.a dn�, b.• . tlosut• r"Otau, so �mi �—Fascia Nail thmuo plAslic c•r-a, .nF ` Swhon requlledp"4,• y� Pdsd�ty IBrn•aehTilrl Uadrrldynwnt 1><- •``.� Z In. widattens Y� 1q EuMrCaurse-__.r Weephoit to Irk."" r�, Farr closure r" r 'UrIpedge Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. • • •.•• •...•• Medium Profile / Double Pin The . • • • 60 1. Starting at the eave course,� pply a minimum 2" •.. (50.8 mm) x 10" (254 rh�•�j 4" (25;4 tggi) foam • • paddy onto the underlayur",positipned4s shown.;..• under the pan portion ofAa file cloAd to the ..a ... overlock of the tile being a ot! a • ....•• 2. Continue in same manner. jit$ure aflproximately���.�; (109.7 cm') —23 (148.4 cm2)'squaraiw1fadhesile ' contact with the underside of the tile! 0 • High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 MritlhroughPtattictem.nt R+rdk1y1B"P&1hT0.'1 Cwlaenrequirad?, UndarLtynl.nt r3( .• ° jµ A4-1 , �. Bamms optional r✓ ` ' „r E.lmcaurs.. a .✓= ram. �,. ,✓;;�,� �dtir4 - t' J yr Fastla r Cave Claire •,�1 f Nail through plastic cennent (When requiredl Paddy (BentathNo) Und.rlaytm.ntj` Tin 't tin. ti [fattens optional � ti10 m �. ,.� 2 in. r Eatir CBnrur. E Ywcn+rrtr' ` fir F �— Friiiw Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile • ... being set. . . . .... ...... 3. Continue in same manner..Wjirq apprOxip%teIy 10"...:. (64.5 cm2) - 12 (77.4 cm').wy'vg inch adhesive . contact with the underside of 11w tile. e. . . • . • .... . .. ..... Medium Profile / Double PahTfle 1. Starting at the eave course, apply a mimYnum•2" (511Y mm) x 10" (254 mm) x 1'''( ,'?.4:nm) fparrl paddy ; • • • • onto the underlayment positioned as slfo gl, uhder the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) !Ja114hrough;p►astircc rrm- twhcnrequire d) �/� P.ddyflRar"hTl■! `tea` 7i f IV I Battens optional / •`' `k ``,� . r Eeve Cow" Fascia Woophou 101n. 2h. // Emacbswr High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overloc?ef t4e tile being set. •••• •••• 3. Continue in same manner. nst re approximately 17 (109.7 cm2) - 19 (122.6 cm�.%quare inj4 adhesive � • • • • contact with the underside gitWtile. • ...... . •• ••••• .. .. .... ...... . . . . ...... NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Nail through plastic cement Paddy (between tiles) lwhen regwredi tuttens optional " Paddy {under tile) Single paddy on top of the i 5uu�►gglepaddi Single paddy on undedayfn`r' 2 x 4 in. - syin Fascia — Eave closure Flat/Low profile Tile Nall through plastic cement Single paddy under the lwherrrequired) Paddylbetween tiles) Battens Paddy [under tilek optional v Single paddy ,T on top of tile--.." 4X4in. 2x41n's. `1 Singgle paddy a undetllaymeM loin. tin. — Eave Closure Eave Course Fascia Medium Profile Tile 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 cm') of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 rr"J;� 1" (25.4 mm) foam paddy onto the uladerlaynNui6jOst below.... the second course line posifioited foaxi paddy .� under the strengthening, Ab or flat the,00r under 1 • • • pan portion of the tile, Cllblse 'to the underlock fcr• • •„ the second course tile tQ *oVi%tallecC'Ins%e ' approximately 8-9 in' (51�e18.1 cm') of adhesive :'•. 1.QJ• . •...• contact with the unders1c• the tile*... •.� � • � • � � • � � � • (Instructions continued on nextMe) • . .. . • .i . . .... NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail through Was&ce , Single paddy under tile {when requ(red) Paddy ibetween tiles) Batterus Paddy (under ti'let mrHnnal , .. om once 7*'4x4in. Single 2 x 4 it paddy on tape tt'le-= Eave Course �� � Fasda r weephole E t0in. �?in• we dosure �. Drip edge High ProflPeTlle 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 1/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. . • .... ..••.• •••... •• . •..•.. • .•.•.• • .. .•••• • • • • • •••••• NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications In contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. i Underlayment ' Sheathing Eave closure I` ' (motar shown) Weephole Fascia Board Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm') — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directVdd 14e inner edge of each side of the aver tile. Le33e "• •. • approximately 3/4" (1 1 mm) to 1'-C2*5•3 qnm) • • ••••• • • •••••• from the outside edge. 9 f flee tile, inward, free o • foam to allow for expamion. • . • : • • • • .... . .. ..... 4. Turn cover tile over afterfmopm is apQked and • • • • • place onto pan tile cotRsC.•lnsure a fAiMmum of• • •; • 20 (129 cm2) - 25 (1(il :3 chi2) square inch • e contact area on each side oithe c&-,4N-t;a to the' •"' • pan tile. Continue in airpe rpanner, Tr0m away • • • • any cured exposed foam adhesive'rp"ttng of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 n M IA��M I-DADE ►�itld - . DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATiON DIVISION NOTICE OF ACCEPTANCE (NOA Polyglass USA Inc. I I I I W. Newport Center Drive Deerfield Beach, FL 33442 MiAMi-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www miamidade.gov/ecnnomy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. • This product is approved as described herein, and has been designed to comply with the F141- da'1'ouilding CUtle •••6,0 including the High Velocity Hurricane Zone of the Florida Building Code. •.. •.• ....,. ...... ..... • DESCRIPTION: poly -lass Polystick Underlayments 0"" ' LABELING: Each unit shall bear a permanent label with the manufacturer's name or log.0 . 0X,atate 3nd'fbhowirlg•" .. .... ...... statement: "Miami -Dade County Product Control Approved", unless otherwise noted lieretp..0.: • . . . . ...... ••...• RENEWAL of this NOA shall be considered after a renewal application has been filed al l t4t7� has been no chat.4g 0 0 • • • • • • • • in the applicable building code negatively affecting the perfonnance of this product. ... . TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Setuino. NOA No.: 17-0614.22 CMIAMIM-DADWECOUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1 of 8 ROOFING COMPONENT APPROVAL Cateaorv: Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick iR-Xe 65' x 313= /s" ASTM D 1970 A fine granular/sand top surface self -adhering, APP 65' x 3' polymer modified, fiberglass reinforced, bituminous facOr Mting 60 mils thick sheet material for use as an underlayment in sloped roof Loccationation#1 & #2 assemblies. Designed as an ice & rain shield. Polystick Dual Pro 61' x 3'3-'/s" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a Manufacturing metal roofing and roof tile underlayment. Location #2 Polystick Tile Pro 61' x 3'3-3/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal Alfanufacturing rooting and roof tile Underlayment. Location #2 Polystick TU Max 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self-adTterij-�g. poly;vu 4reinforeoc�•e9 60 mils thick ASTM D 1970 waterproofing membrane. DeSlgntd as a Vrpbf the ***ire* •• • ...... Manufactt.0 irrg underlayment. • • • • • • • • Location- # 1 & #2 Polystick TU P 32' 10" x 3'3-'/K" • TAS 103 and A rubberized asphalt waterprooT1-,g meWriar e.* so, glass6600 130 mils thick ASTM D 1970 fiber/polyester reinforced, \%ijfja granular st;rface ••�••• Manufacturing designed for use as a tile rootuiad'erlayn'iew%....... Location #2 ...... . • Polystick TU Plus 65' x 33= /K" TAS 103 and A rubberized asphalt self-acpiertnj, glas$-fiber/poly ester (Surface Printing) 80 mils thick Dasi�rSeci as a metal . ASTM D 1970 reinforced waterproofing membr. ane. .. al . roofing and roof tile underlayment. sees • Manufacturing sees Location # t & 92 Polystick MTS 65'8" x 3'3-;/s" TAS 103 A homogeneous, ntbberized asphalt waterproofing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Manufacturing on the upper surface for use as an underlayment for metal Location #2 roofing, roof tile, slate tiles and shingle underlayment. Polystick MTS Plus 65'8" x T3-3/8" TAS 103 A homogeneous, rubberized asphalt waterproofing fiber reinforced with potyolefinic film Manufacturing 60 mils thick membrane, glass on the upper surface for use as an underlayment for metal Location #2 roofing, roof tile, slate tiles and shingle underlayment. Elastoflex S6 G 32' 10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane ASTM D 6164 with a sanded back face and a granule top surface. For Manufacturing use in roof tile underlayment systems. Location #2 NOA No.: 17-0614.22 MIAMI•DADECOUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED Test Allency Test Identifier Test Name/Report Date Trinity I ERD P10870.09.08-R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4799 & G 15 5 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.1 1 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-2 ASTM D 1623 08/07/12 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103, TAS 110 & ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 & TAS 110 10/07/14 P43290.10.14 ASTM D 1970 & TAS 110 10/17/14 PLYG-SC10130.06.16-3 TAS 103 & TAS 110 06/27/16 PLYG-10130.06.16-1 ASTM D1970 & TA$ 110• . •,,*66/27/16•�••• . PRI Asphalt Technologies PUSA-035-02-01 TAS 103 •• • ••••l79/29/06 '. PUSA-055-02-02 TAS 103 ...%. PUSA-089-02-01 TAS 103/ASTM D4798 &eQ,155 . .... .. 07/06/09"": . . . Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798*=i155 . .. ..... ; .•6�/0l/04�•0••� "�11/09/W * RX14E8A TAS 103/ASTM 1)4798, .Z 155 DX23D8B TAS 103/ASTM D4798:& Cil55 D2/18/I *��• DX23DSA TAS 103/ASTM D4798•& G155 .. . .... . 2/18/1: . . .. . . LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. QMIAMMI.D�ADE COUNTY VT= BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 17-0614.22 MIAMI•DADECOUNTY Expiration Date: 09/1.3/21 "' • Approval Date: 07/06/17 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 151.8.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) ."". . . .... ...... Membrane: Elastoflex S6 G, hot asphalt applied •• •• • Surfacing: See General Limitations Below. """ " ' •••••• .... . .. ..... Deck Type 1: Wood, non -insulated •••••• .. ..:..' Deck Description: Min. 19/32" plywood or wood plank �• •• "" """ System Type E(3): Base sheet mechanically fastened to deck, subsequent cap 44eAl*iane self- adhered..:% ...... Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626. • •. . . .. • • • • • • Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4+nCad lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 17-0614.22 MIAMMDADEGOUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the cave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. .... GENERAL LIMITATIONS: • . . .... ...... 1. Fire classification is not part of this acceptance. • • • ...... .. . ...... 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick NITS and Pe"ick NITS Pius may be used in asphaltic shingles, wood shakes and shingles. non-structural metal roofing, �CC?tle systr%s aijd quarry • .... . .. ..... slate roof assemblies. . ' ...... .. ..... Polystick TU P may be used in all the previous assemblies listed except metal roofing'...' 0 0 0•••••• Polystick IR-Xe may be used in all the previous assemblies listed except metal roo-M1qaAd roof the systems. Polvstick TU Max may be used in non-structural metal roofing and roof tile systems. 0 ...... . . . Elastoflex S6 G may be used in roof tile systems only. • • 0 • • 0 • • • • •; 3. Deck requirements shall be in compliance with applicable building code. •••• 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polvstick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS and Polystick NITS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS and Polystick NITS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS and Polystick NITS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Ex osure Limitations Days i\TrS IR-Xe Elastoflex TU TU P Tile Pro Dual Pro TU Max NITS Plus S6 C Plus Winter Haven, FL 180 90 180 180 l80 180 180 180 180 Hazelton, PA N/A 90 N,/A 180 N/A N/A N/A 180 N/A 7. All products listed lierein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 MIAMI-DADE COUNTYM Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 Rule 61G20-3 of the Florida Admit In roof the application, data for the manufacturer's Notice of Acceptan Polystick Tile Pro, Polystick TU set and mechanically fastened roof Polystick Dual Pro is limited to m Polystick MTS and Polystick MT Section 9. Polystick TU P may be used in mE applications. tive Code. resistance of roof tiles shall be as set forth in the roof tile lax, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive le applications. ,hanicatly fastened roof tile applications. Plus are limited to mechanically fastened with the limitations outlined in hanically fastened roof tile applications with the exception of mortar set tile 9. When loading roof tiles on roof the underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastotl x Polystick TU Plus, Polystick Polystick System (E3) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus MTS Plus with Dual Pro TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens The above slope limitations can be exceeded only by using battens in accordance with the Appro va6UC System Notice of Acceptance and applicabl Florida Building Code requirements. When badens,9re requi?&t,•they slrAi-:- be utilized during loading and installation of tiles. ����•• ••0•�• ••���� 10. Care should be taken during the loa ling procedure to keep foot traffic to a minimum'tttdo"avoid dropping of ��•� tile directly on the underlayment. R fer to Polyglass' Tile loading detail below for loc!ltn�proceddre =,Iwo tiles • laid perpendicular to slope followe by a maximum four tile stack parallel to the slope,.... tota�of00 files all underlayments except Polystick MTS which shall be loaded onto battens. . % POLYS7, CKiIJ Flu; ••••.• NOA No.: 17-0614.22 MIAMEDADECO j& Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Pi specific prepared roofing products. Max, Polystick TU P, Polystick T used with any approved roof coveri Polystick Tile Pro, Polystick TU I Plus or Elastoflex S6 C as a comp If Polystick IR-Xe, Polystick Du: TU Plus, Polystick NITS, Polystic Authority Having Jurisdiction (AH that appropriate documentation is I testing results. POLYGLASS GENERAL A PLEASE CHECK WITH LOCAL BUI LOCAL CODES IMAY SUPE1 I. Polyglass does accept the direct ap cautioned to refer to applicable loc Please also refer to applicable Proc 2. All rolls, with the exception of Pol Back Nailing Guide. Nails shall bi required in Miami -Dade County of of 12" o.c. Polystick TU Plus shot the face of membrane, with the ab( back -nailed. (Please refer to applic 3. All seal lap seams (selvage laps) n 4. All fabric over fabric; and granule Polyplus 55 Premium Modified FI XtraFlex 50 Premium Modified w the application of the lap. The use 5. A maximum of 6 tiles per stack ar Loading Guidelines. See General 6. Battens and/or Counter -battens, a: pitch/slopes of T712" or greater. taken, such as the use of battens t( duct Control Notice of Acceptance for listed approval of this product with 'olystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS, Polystick NITS Plus or Elastoflex S6 G may be g Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, ax, Polystick TU P, Polystick TU Plus, Polystick NITS, Polystick NITS rent part of an assembly in the Notice of Acceptance. Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick 'NITS Plus or Elastoflex S6 C are not listed, a request may be made to the i or the Miami -Dade County Product Control Section for approval provided ovided to detail compatibility of the products, wind uplift resistance, and fire LICATION GUIDELINES FOR POLYSTICK MEMBRANES ING CODES REGARDING LimiTATIONS OF SPECIFIC APPLICATIONS. ME POLYGLASS REQUIREMENTS AND RF,COMMENDATIONS. )lication of Polystick underlayment membranes to wood decks. Installers are [l building codes prior to direct deck installation to ensure this is acceptable. act Data Sheets of the corresponding products. •....• stick TU Plus should be back -nailed in selvage et �soam as I:`r ):olygla1s9•. 1 1 gauge ring shank type, applied with a rmninw-Qj.`1V me%i distr as ••••.• simplex type nail as otherwise allowable in other#cgi4ws, at a minimum rate Id be back nailed in designated area marked "nailAr",•area pw. davar can ve stated nails and/or disks. The head lap membrane ►s to coder ttit area bt�iPb•. ...... . .. ..... able local building codes prior to installation.) • .. .. .... ...... . List be rolled with a hand roller to ensure full coplAC •: 00 •. . . ......0 aver granule end laps, shall have a 6" wide, uniform layer ofVolyArass . ...... .shing Cement, Polyglass Polyplus 50 Premium M$ Flashing;Cjn%nt, • -t/Dry Cement, Polyglass PG500 MB Flashing Cement, appli(Af"between of mastic between the laps does not apply to Polystick NITS. allowed when loading the on the underlayments. Refer to the Polyglass Tile ,imitations 99 and ## 10. required by the tile manufacturers NOA, must be used on all projects for t is suggested that on pitch slopes in excess of 6 ''/4"/l 2", precautions should be prevent tile sliding during the loading process. 7. Minimum cure time after membra ie installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be ised in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wct/Dry Cement, Polyglass PGS 0 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a mininnuri o 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or MIAMMADE COUNTY • er the top of all laps of the patch. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 10. All self -adhered membranes must be minimum of 40 lbs for a weighted rc rolling of patches or small areas of tl 11. All approved substrates should be dr membranes commences. An approv recommended to refer to applicable 12. The Polyglass Miami -Dade Notice c upon request by our Technical Servi 13. Questions in regards to the applicati Department at 1 (800) 894-4563. 14. Polyglass recommends that applicat the National Roofing Contractors A rolled to ensure full contact with approved substrates. Polyglass requires a ler for the rolling of the field membrane. Hand rollers are acceptable for e roof. Brooming may be used where slope prohibits rolling. /, clean and properly prepared, before any application of Polystick d substrate technical bulletin can be furnished upon request. It is ,uilding codes prior to installation to verify acceptable substrates. Acceptance (NOA) approval for Polystick membranes can be furnished ;es Department by calling 1 (800) 894-4563. rn of Polyglass products should be directed to our Technical Services follow good roofing practices and applicable procedures as outlined by ciation (NRCA). PLEASE CHECK WITH LOCAL BULL. ING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES NNIAY SUPERS�DE POLYGLASS REQUIREMENTS AND RECONIMENDATIONS. E IIAMFDADE TOUNTY .1 OF THIS ACCEPTANCE . . .... ...... ...... ... ...... .... . .. ..... ...... . .. ..... . . . . ...... NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8 of 8 MIAMI DADE cl• DEPARTMENT OF REGULATORY AND EC9NONIIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE NOA Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 1 1805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 ww w.miamidade.f!ov/economv SCOPE: This NOA is being issued under the appli able rules and regulations governing the use of construction materials. The documentation submitted has been review rd and accepted by Miami -Dade County RER - Product Control Section to be used in Mianui-Dade County and other ar as where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the exp (in Miami -Dade County) and/or the AHJ product or material tested for quality assu manner, the manufacturer will incur the c suspend the use of such product or materi if it is determined by Miami -Dade Count, requirements of the applicable building c( This product is approved as described her including the High Velocity Hurricane Zc DESCRIPTION: Barcelona 900 LABELING: Each unit shall bear a pert statement: "Miami -Dade County Product RENEWAL of this NOA shall be consi in the applicable building code negativel -ation date stated below. The Miami -Dade County Product Control Section n areas other than Miami -Dade County) reserve the right to have this ance purposes. If this product or material fails to perform in the accepted pense of such testing and the AHJ may immediately revoke, modify, or 1 within their jurisdiction. RER reserves the right to revoke thiS*Ategtance, Product Control Section that this product or material fE ilc to melt'4ire ••••:• . . in, and has been designed to comply with the Florid4,:"Iding Code • • •••• ie ol�the Florida Building Code. .•.• •. • •. . -oncrete Roof Tile •••••• •• ••%••• .... .... ...... • anent label with the manufacturer's name or logo,crty state and following • :ontrol Approved", unless otherwise noted herein, ;••••• ,red after a renewal application has been filed and there has beentio change• affecting the performance of this product. TERMINATION of this NOA will occu - after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA numb r preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the jo This NOA revises NOA No. 1 8-0509.15 The submitted documentation was revi site at the request of the Building Official. consists of pages 1 through 7. by Fredtr y Sel ino NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAI Catcgorv: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system usii in Lake Wales, F1, and described determined by applicable Building compliance with RAS 127 using th shall be done as a moment based s 2. PRODUCT DESCRIPTION Manufactured by Applicant Barcelona 900 g Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC his Notice of Acceptance For locations where the pressure requirements, as Code, do not exceed the design pressure values obtained by calculations in values listed in the installation section herein. The attachment calculations Lengt i = 17" Widtl = 13" h" thick 'Pest Specifications TAS 112 Type — 1 a Trim Pieces Length: varies TAS-i 12 Width-: varies varying thickness 2.1 PRODUCTS MANUFACTUR D BY OTHERS Product Name ICP Adhesives Polyset( AH-160 TILE BOND'" Roof Tile Adhesive DAP Foam Touch N Seal StormBon0' 2 Roof Tile Adhesive Product Description T,} o component polyurethane fobm adhesive. Sij gle component polyurethane fo in roof tile adhesive. T o component polyurethane to m adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL Product Description High profile, interlocking, one-piece, 'S' shaped, high-pressure extruded concrete roof tile equipped with three nail holes. Fo��IjWct deck or battened nail -on, mechanically• fai"itd, ...... • mortar set or adhesivc-8�t ;plicali4msi, •• Accessory trim, booste1l;1rcelona, concrete000 ;....; roof ieces for use ar l s rakes,0rd�es•nnd valley terminations iwgv"pturecj for qpch tile..:.. - profile. .• •• .•.• •••••• 000000 • •••.•, • t 1\'lanufacturer; •••. • •.•• (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam tile. NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test Agency Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Professional Service 111CIUStrieS, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. Walker Engineering, Inc. American Test Lab of South Florida PRT Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies Test Identifier 7161 Appendix III 7161-03 Appendix 11 110402 Letter Dated Aug. 1, 1994 P0631-01 IC-1320-94 25-7688-3 25-7688-10 25-7688-5 25-7688-4 52011 1-3 520191-2-1 Calculations Evaluation Calculations RT0617.03- 16 COPO-002-02-10 COPO-002-02-02 COPO-002-02-01 Test Name/Report Static Uplift Testing TAS 102 & TAS 102(A) Wind Tunnel Testing TAS 108(Nail-On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Soti. Physical Propewti:'I.. TAS 112 •••••- TAS 101 (AdhesiV:*A*. 1J TAS 101 Nortar.Sat-. Static Uplift Tesfin�*• TAS 102 (3" Headlap, Nails. Direct Deck, New ConstrticOon; Static Uplift Testing TAS 102 (4" Headlap. Nails, Clips) Static Uplift Testing TAS 101 Aerodynamic Multiplier Restoring Moments Due to Gravity TAS 112 Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Adhesive Set) Date Dec. 1991 . Dec. 1991 Sept. 1993 Aug. 1994 .InFI1994 .... ...... •F4!1995 ••••'• . .. ;J dry. 1996 ..... .Jul+y1996 . . tuns 1996 •••��• .rune 1996 Dec. 1998 March 1999 09/01 / 16 09/01 / 16 06/29/ 16 10/12/2016 10/12/2016 10/12/2016 � MIAMI•DADE CNOA No.: 19-0408.02 OUNTY Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 3 of 7 I LIMITATIONS: 3..1 3.2 3.3 3.4 3.5 3.6 Fire classification is not part of this acceptance. For mortar or adhesive set the pplications, a static field uplift test in accordance with TAS 106 may require, refer to applicable building code. Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Department of Regulatory and Economic Development — Iroduct Control Section for review. Minimum underlayment shall be in compliance with the applicable Rooting Applications Standards listed section 4.1 herein. 30/90 hot mopped underlaymer t applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. This acceptance is for wood de k applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Barcelona 900 Concrete Rooi Application Standard RAS 11 4.2 Data For Attachment Calculai . . .... ...... Tile and its components shall be installed in strict 0001riprancekvitlz1?*oofin4•.•�• 3, RAS 119, and RAS 120. • ions •••••• .... . .. ..... ...... . .. ..... .. .. .... ...... Table 1: A erage Weight (W) and Dimensions (I x w) • • • • Tile Profile Wei ht-W (Ibf) Length -I (ft.) yam• ••Y1lidthILw (ft.) •' Barcelona 900 111.5 1.417 1.L14..- Table Aerodynamic Multipliers - A (ft3) Tile Profile Ba A (ft3) tten Application A (ft3) Direct Deck Application Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity - Mg (ft.-Ibf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Barcelona 900 Battens Direct Deck Battens D Deck rect Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 6.60 5.76 6.42 NOA No.: 19-0408A2 MIAMbDAD: couNTY Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 4 of 7 8. 9. Rule 61G20-3 of the Florida Administrative Code. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastotlex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof the applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastotlex Polystick TU Plus, Polystick Polystick System (E3) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus MTS Plus with Dual Pro TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens The above slope limitations can be exceeded only by using battens in accordance with the Appro vod.Tile System Notice of Acceptance and applicable Florida Building Code requirements. When bat=ens.1re requik'd,•they slFU**:- .. •• . . be utilized during loading and installation of tiles. • . 0,00000 10. Care should be taken during the loading procedure to keep foot traffic to a mininn.tm'Ititl-tttavoid dropping of:....� tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loatltu�procedlrx -!�-4wo tiles • laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, fro*r totatofV tiles—T8:*O. all underlayments except Polystick MTS which shall be loaded onto battens. d 0 N F1 P==1 1:3 POL'Y57, CKTU Plus • • • • ... NOA No.: 17-0614.22 MIAMMADECOUNTY Expiration Date: 09/13/21 1 ' Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick iR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS, Polystick NITS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick NITS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES RFGARDING LiMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. •••.•• 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage c+sgam as 4er l:olyglaW•. Back Nailing Guide. Nails shall be, 1 i gauge ring shank type, applied with a rmninr4"J.Y8" me%l�disk as ••.•.. required in Miami -Dade County or simplex type nail as otherwise allowable in otherPc+giocs, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "naiLAr",.area 1:wa o4avar' 450 the face of membrane, with the above stated nails and/or disks. 'The head lap membraM ISt o cover t1rt area be r� . *00 back -nailed. (Please refer to applicable local building codes prior to installation.) •� 666069 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full corIAC:•: • 4. All fabric over fabric: and granule over granule end laps, shall have a 6" wide, unifCrm hkXer ofVoljArass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium M$ Fl�shin;Cgnrept, • XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, appIlA?"between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations 99 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7 /12 or greater. It is suggested that on pitch/slopes in excess of 6'/4"/12", precautions should be taken, such as the use of battens to prevent the sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 MIAMI•DADECOUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 Ibs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES NIAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE ...... . .. ..... .... .... ...... . . . . ...... NOA No.: 17-0614.22 COUNTY Expiration Date: 09/13/21 C I Approval Date: 07l06/17 Page 8 of 8 M IAM I•DADE MIAMI-DADE COUNTY 0 PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND > CONONi1C RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (N'OA) www.miamidade.2ov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 1.00 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke thiSlattegtance, if it is determined by Miami -Dade County Product Control Section that this product or materi"al fiuilc to meet'Phle "••:• .. . •I . requirements of the applicable building code. • This product is approved as described herein, and has been designed to comply with the FloridIL�41ding Co4e including the High Velocity i-lurricane Zone of the Florida Building Code. •••• •• • ;"••: • . • • • DESCRIPTION: Barcelona 900 Concrete Roof Tile •'•••• •• ••:••' .... .... ...... LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, ilb0 sitte and following •����� statement: "Miami -Dade County Product Control Approved", unless otheiAvise noted herein, ;••••• • RENEWAL of this NOA shall be considered after a renewal application has been filed and t%ere has beendio change' ' .•• in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.] 8-0509.15 and consists of pages 1 through 7. The submitted documentation was reviewed by Fredy Semi'no U NOA No.: 19-0408.02 CM1AM1W-DADMEC0=UNTY Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Catetory: Roofing Sub-CateLmry: Roofin(y Tiles Material: Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FI, and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by "rest Applicant Dimensions Specifications Barcelona 900 Length = 17" TAS 112 Width = 13" Type — 1 a %2" thick Trim Pieces Length: varies TAS-1 12 Width: varies varying thickness 2.1 PRODUCTS MANUFACTURED BY OTHERS Pradivot 1Vamr ICP Adhesives Polysetf. AH-160 TILE BOND" Roof Tile Adhesive DAP Foam Touch N Seal StormBondr" 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL Product Description High profile, interlocking, one-piece, 'S' shaped, high-pressure extruded concrete roof tile equipped with three nail holes. FoL�ct deck or battened nail -on, mechanically fai"itd, •••••• mortar set or adlesive j t-;pIicajim.s% •• •••••• •• • •••••• Accessory trim, boosteV9, rcelona, cUncrete ;..•.; *Peeroof pieces for use aPLiLps+sakes,-widyeseand • valley terminations ivgyV"pturcc for *ch tile••:••••.. • profile. .. .. ...• .••... Manufacturer: •••• • (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam Inc. NOA No.: 19-0408.02 MIAMI•DADE COUNTY Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test A2ency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 . Appendix III TAS 102 & TAS 102(A) Redland Technologies 716 Wind "Tunnel "Testing Dec. 1991 Appendix II TAS 108(Nail-0n) Redland Technologies P0402 Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing .Inry 1994 TAS 108 (Mortar Sots. • Professional Service industries, Inc. IC-1320-94 Physical Properti**•• •Fe94995 •••••• TAS 112 ...••• 0 ' The Center for Applied Engineering, Inc. 25-7688-3 TAS 101 (Adhesive*e,1I ;Jttrw.t996 ..... 25-7688-10 TAS 101 (Mortax.%11 :.ItIl�1•1996 ••.•• The Center for Applied Engineering, Inc. 25-7688-5 Static Uplift TesfinU• lime 1996 ••••'� TAS 102 • ' . . (Y Headlap, Nails. Dirt ec . . ;""' ...... Deck, New Constrtic0Z)n; • • • The Center for Applied .Enginecring, Inc. 25-7688-4 Static Uplift Testing June 1996 TAS 102 (4" Headlap, Nails, Clips) Celotex Corporation 52011 1-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier 09/01/16 Walker Engineering, Inc. Evaluation Restoring Moments Due to 09/01/16 Calculations Gravity American Test Lab of South Florida R"1'0617.03-16 TAS 112 06/29/16 PRI Construction Materials Technologies COPO-002-02-10 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRf Construction Materials Technologies COPO-002-02-02 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-01 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 3 of 7 3. Limi tTATiONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may require, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Department of Regulatory and Economic Development — Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION •••••• . . .... ...... 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compiianceivitlot?*oofin4 •• ...... .. . ..... Application Standard RAS 118, RAS 119, and RAS 120. •••�•• • 4.2 Data For Attachment Calculations • • • • • • 0000*0 : . •• •• •••• **:*O Table 1: Average Weight (W) and Dimensions (I x w ) :••:•: Tile Profile Weight-W (Ibf) Length-1 (ft.) ••YVidth--w (ft.) Barcelona 900 11.5 1.417 •' 1.LlF�..' Table 2. Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 6.60 5.76 6.42 1voA No.: 19-o4os.o2 MIAMbDAD; couNTY Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank 5.1 6.8 2.8 Nail 2-10d Smooth or Screw Shank 6.9 9.2 7.3 Nails 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank 23.1 23.1 19.0 Nail Field Clip) 1-10d Smooth or Screw Shank 29.3 29.3 •��4.0 -Nail Eave Cli - 2-10d Smooth or Screw Shank 27.6 27.6' ' ..38.6 Nails (Field Clip) .••••• .••••• 2-10d Smooth or Screw Shank 38.1 38!t�•• 41.8 Nails Eave Clip) ."". :'. '. • Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) •••• ' for Mechanically Attached Systems :":': . . . . Tile Fastener Type Direct Deck Direct Deck attens • Profile (min 15/32" (min. 1q/32'' .••. ' plywood) plywood) • Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4" the headlap and fasteners are located a min. of 2'/z" from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Paddy Adhesive' Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Tile BondTMOne Component Roof Tile Adhesive 29.32 ICP Adhesives PolysetO AH-160 two -component foam 29.33 DAP Foam Touch N Seal StormBond R 2 Roof Tile Adhesive 664 1 See manufactures component approval for installation requirements. 2 TILE BONDTm Roof Tile Adhesive; Average weight per paddy 10.7 grams. 3 ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160; Average weight per paddy 8 grams. 4 DAP Foam Touch N Seal Storm Bond") Roof Tile Adhesive Two -Component; Average weight per paddy 8 grams. MIAMI•DADE COUNTY "Z NOA No.: 19-0408.02 Expiration Datc: 04/26/22 Approval Date: 05/16/19 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 ICP Adhesives PolysetV AH-160 two -component foam 66.55 ICP Adhesives Polyset't� AH-160 two -component foam 38.7 6 DAP Foam Touch N Seal StormBond02 63' DAP Foam Touch N Seal StormBondZ 2 82 8 5 Large paddy placement of 63 grams 6 Medium paddy placement of 24 grams 7 Medium paddy placement of 30 grams 8 Lar e addy placement of 60 grams Table 8: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems ."". Tile Tile '..' ktach= Profile Application •••;•Resistance• •• Barcelona 900 Mortar Set' .,., 24,-1 :• N fA t • lose: 9 Sees ecific mortar manufacturers once o cce ance • • • • • • • • • • ...... . .. ..... 5. LABELING •• •• +••• •••••• 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's dame or lob%�gegetailed•••�• below, or following statement: "Miami -Dade County Product Control Approved'; • OR LABEL FOR BARCELONA 900 TILE LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 6 of 7 17" PROFILE DRAWING OVERLOCK y� 35/8" 13 ...... • UNDERLOCKzz , '•" ...... .. BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date, 05/16/19 Pale 7 of 7