Loading...
RF-19-1294Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑ ROOFING ,C I E JUN 016 2 9 BY: t , B(' C 20 d Master Permit No. i'`0 �-1 IG� 1 Z5 J Sub Permit No. ❑ REVISION ❑ EXTENSION [:]RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Ik -,wQ6 Sj 30 Is the Building Historically Designated: Yes NO Occupancy Type: Load: �j Construction Type: Flood Zone: BFE: FF�E:� OWNER: Name (Fee Simple Titleholder): Phone#: ��✓ I���/ Address: QG c5-t ` City: OY� $ State: -- Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR any Name: S iy Phone#: -D � Gh 1. i j �C}5-11 2- -��RS Address: City: I ' State: Zip:1� Qualifier Name: Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 1 �� Square/Linear Footage of Work: q(oo Type of Work: ❑ A dition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Specify color of color thru tile:\ 1P- Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ Do0 TOTAL FEE NOW DUE $ 217 • ( V (Revised02/24/2014) Bonding Company's Name (if applicable) • Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signatu OWN r AGENT The foregoing instrument was acknowledged before me this D day of JA t', 120 by 6� My,711 who is personally known to me or who has produced Lt ,%%t as identification and NOTARY PUBLIC: Sign: Print: a11� Seal: DANIEL GONZALEZ MY COMMISSION Ir GG 250277 EXPIRES: August 19, 2022 Bonded Thru Notary Ptft Wdeiyrkw Ztt The N-� CONTRACTOR ng instrument was day of�� me or who has produced iowledged befor a this 20 by who ' p sre onall nown-i as identification and who did take an oath. NOTARY Sig Print: Sea\ APPROVED BY "( Plans Examiner �<. c��, e�? I �REDAWE te -St teNotary Floridar'Commi,s,on -4769 My Comm Exo,resNov 3.2020 ************ Zoning Structural Review (Revised02/24/2014) Clerk I a Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: —_ 6(ny `i �o� 1 Property Address: Roofing Permit Number: Dear Building Official: GY tew certify that I am not required to retrofit the roof to wall connections of my building because: XThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature Print Name I DANIELGONZALEZ State of Florida n;+: MY COMMISSION # GG 250277 County of Dade b`:' _ EXPIRES :August 19, 2022- The undersigned, being the first duly sworn, deposes and says thaT'ie/s a is the owner for the above property mentioned. Sworn to and subscribed before me this day of Mu d-O If Notary Public, Sate of Florida at Large -"0/ When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 5/13,Q019 ,. Property Search Application - Miami -Dade County FFI�E -OF THE PROPERTY APPRAISER t� Summary Report Property Information Folio: 11-3206-013-5430 Property Address: 358 NE 100 ST Miami Shores, FL 33138-2421 Owner GREGORY MUZII &W BEVERLY G. Mailing Address 358 NE 100 ST MIAMI SHORES, FL 33138-2421 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Beds / Baths / Half 2/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,064 Sq.Ft Lot Size 8,625 Sq.Ft Year Built Multiple (See Building Info.) Assessment Information Year 2018 2017 2016 Land Value $258,854 $258,854 $215,711 Building Value $145,259 $145,526 $145,794 XF Value $23,760 $23,946 Market Value $427,873 $428,326 d$385,636 Assessed Value $271,152 $265,575 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $156,721 $162,751 $125,523 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 1 5341 6 53 42 MIAMI SHORES SEC 1 AMD PB 10-70 W1/2 OF LOT 4 & ALL OF LOT 5 BLK 40 LOT SIZE 75.000 X 115 Generated On : 5/13/2019 Taxable Value Information 2018 2017 2016 County Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value $221,152 $215,575 $210,113 School Board Exemption Value 1 $25,000 $25,000 $25,000 Taxable Value $246,152 $240,575 $235,113 City Exemption Value 1 $50,000 $50,0001 $50,000 Taxable Value 1 $221,152 $215,575 $210,113 Regional Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $221,152 $215,575 $210,113 Sales Information Previous Sale Price OR Book -Page Qualification Description 05/01/2000 $215,000 19199-2898 Sales which are qualified 05/01/1986 $123,000 12888-1173 Sales which are qualified 04/01/1984 $105,000 12119-1081 Sales which are qualified 04/01/1973 1 $40,000 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renaded in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. �8►g wner ge is ature Date Property Addre s Revised on 7/9/2009 LD;07/01/2015; Con or Signature Date Permit Number Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 06/10/2019 Location Address Parcel Number 358 NE 100TH ST, Miami Shores, FL 33138 1132060135430 Contacts Permit NO.: RF-06-19-1294 Permit Type: Roof Work Classification: Flat Permit Status: Approved Expiration: 12/09/2019 GREGORY MUZII Owner T&S ROOFING SYSTEMS INC. Contractor 358 NE 100 ST, MIAMI SHORES, FL 331382421 LOUIS TOLEDO 1461 NW 23 ST, MIAMI, FL 33142 Business: 3052652654 Other:3057727954 Description: RE -ROOF FLAT (WHITE) Valuation: $ 7,000.00 Inspection Requests: 305-62-4949 TotalSq Feet: 900.00 Fees Amount Application Fee - Other $50.00 CCF $4.20 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $1.40 Roofing Fee $200.00 Scanning Fee $9.00 Technology Fee $6.25 Total: $277.10 Payments Date Paid Amt Paid Total Fees $277.10 Check # 36285 06/10/2019 $277.10 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contA to to do the work stated. ^ 1' MA Authorized Signature: Owner / Applicant / Contractor / 'Agent' — Date June 10, 2019 Page 2 of 2 Sccjinn AB ,A .•9 COUNTY "Delivering Excellence Every Day" Miami -Dade County HVHZ Electronic Roof P rmit Form" RE EIV D! Section A (General Information) JUN 0 619 Master Permit No: Process No: Contractor's Name: AND S ROOFING Job Address: 358 NE 100 ST 7777 ❑✓ Low Slope Roof Category ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Other: Roof Type ❑ New Roof ❑'' Re -Roofing ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes 0 No If yes, what type? ❑ Natural ❑ LPGX Roof System Information Low slope roof area ft') 900 , Steep Sloped area ft') 0 Total (U) 900 11 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): E::� Corner Size (a' x a'): O 1)4 - _ ; '-F 'T CT TO C •1F,IANCE VFH ALL FE':'_R,'aL IC-„ , ITY F 1 r-g AN— ��� AT"" NS Florida Building Code 5th Edition (2®.17) ` High -Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof Sy§te Fill in Specf>fc Roof Assembly Components and Identify Manufat tuner (If a component is not useed,, iden#fy as `NA') system Manufat�r. NOA No.• - �� - �� Design Wind Pressures, From RAS 128 or Calculations: Pam. -I: iy u Pmax2:� Pmax3: I U v Fastener Spacing for Anchor/Base Sheet Attachment Field: _I - w a Lap, 0 Rows � � -I- oc Perimeter: Lm oo @ Zap, # Rows 4 @ j_° or; .Comer. 6 'or; @ Zap, #Rows_, @� .0c Number of Fasteners per Insulation Board Max. Design Pressure, F • m the Speffw NOA System r 3 -7 - E Field Perimeter Corner AnchorMase Sheet Fastenerffiondrxi Material: Insulation Base layer. Base Insulation Site and Thiciat— Base Insulation FastenedBonding Material. Top Insulation -Layer: Top Inundation S'¢e and TM Top Insulation Fastenerffioncrmg trlaterial: Base Sheets) & No. of Ply(# A (S q 5� Base Sheet Fastener/Bonding Material: Ply Sheets).& No. of Piy(s): k) i I I Ply Sheet sien ,ding Materi 1, } Top Ply H I Top Ply Fastens Bonding Materia Surfacing; Iflusttmte Components Noted and Details as Applicable, Woodblocking, C-u'fter, Edge TenT ination, Stripping, Flashing, Continuous Cleat Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Relght, Parapet Height, Height of Base Flashing, Component Material, Material T hiclaiess, Fastener Type, Fastener Spacing or SL&n* Manufacturers Details that Corn piy. wM RAS I I i and Chapter 16. - FT-.HeW i h� - arapet Mean Roof Height 3/27/2019 ROOFING SYSTEMS I UL Product iQ ;,Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation ihstructions,(excluding "LRF Adhesive O") in any applicable Non -Combustible Roof Deck Classifications. "EnergyGuardTM Tapered" is an acceptable alternate to "EnergyGuardTM" in any applicable Classification. "EnergyGuardTM Ultra Tapered" is an acceptable alternate to "EnergyGuardTM Ultra" in any applicable Classification. "EnergyGuardTM' NH Tapered" is an acceptable alternate to "EnergyGuardTM NH" in any applicable Classification. "EnergyGuardTM' NH Ultra Tapered" is an acceptable alternate to "EnergyGuardTM' NH Ultra" in any applicable Classification. "EnergyGuardTM Barrier Tapered" is an acceptable alternate to "EnergyGuardTM Barrier". "EnergyGuardTM NH Barrier Tapered" is an acceptable alternate to "EnergyGuardTM NH Barrier". Minimum 1/2-in. thick "EnergyGuardTM Barrier" is an acceptable alternate to "EnergyGuardTM Ultra" in any applicable Classification. Minimum 1-in. thick "EnergyGuardTM NH Barrier" is an acceptable alternate to "EnergyGuardTM NH Ultra" in any applicable Classification. "Tapered EnergyGuardTM' RA" may be substituted for "EnergyGuardTM' RA" in any of the systems listed below that utilize "EnergyGuardTM RA". "EnergyGuardTM RA" may be perforated on one side for use as the contact side for BUR or modified bitumen membrane. ASPHALT FELT SYSTEMS WITH MOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ("GAFGLASO #75 Base Sheet" or 'Tri-P1y(D #75 Base Sheet" or "GAFGLASO #80 UltimaTM' Base Sheet") is a suitable alternate for Type G1 asphalt glass fiber ply sheet ("GAFGLASO Ply 4" or "Tri-Ply® Ply 4" or "GAFGLASO Flex Ply 6" or "Tri-PlyO Ultra - Flexible Ply 6'� in the Class A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAFGLASO Stratavent® Nailable Venting Base Sheet" or "GAFGLASO Stratavent(D Perforated Venting Base Sheet". Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically fastened granule side down. As an option Type G2 asphalt glass mat base sheet ("GAFGLASO #75 Base Sheet" or "Tri-PlyO 475 Base Sheet" or "GAFGLASO #80 Ultimal Base Sheet" or "GAFGLASO StrataventO Nailable Venting Base Sheet') may be substituted for Type G1 asphalt glass fiber ply sheet.("GAFGLASO Ply 4" or "Tri-Ply@ Ply 4" or "GAFGLASO Flex Ply 6" or "Tri-PlyO Ultra -Flexible Ply 6") as the nailed base ply in the following systems. Bottom ply.or base sheet may be fully adhered with hot roofing asphalt or mechanically fastened. Unless otherwise indicated, all insulations may be fully adhered with hot roofing asphalt or mechanically fastened. "GAFGLASO Flashing" or "RUBEROIDO" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes any UL Classified perlite insulation. Crushed stones or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Gass A, B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of 1/2-in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum 3/44n. thick perlite board and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. Trumbull "Perma Mop" may be utifized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLASO #80 UltimaTM Base Sheet" may be used in any of the following systems. 'GAFTJ EMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "United CoatingsTM FireShield MB Roof Coating" applied at a rate of 2-1/2 to 3-gal/100-ft2. Class A, B and C Hot roofing asphalt, for use with glass felts. or modified bitumen membranes. Torch applied "RUBEROIDO Heat Weld" SBS roofing membranes may be used as alternates to "RUBEROIDO Mop" SBS roofing membranes in any applicable Classification. "RUBEROIDO HW 25 Smooth" may be used as an alternate to "RUBEROIDO Mop Smooth" or "RUBEROIDO Mop Smooth 1.5". Class A J ROOFING SYSTEMS I UL Product iQ '12019 Incline: 3 Gypsum LLC "DensDeck® Roofboard" or .. ,!�ck-`C-15/32 y sum Co. Barrier Board (optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific -i " or DensDeck® DuraGuardTM' Roofboard" or minimum RYPe SGMRX)ck United States G p "DensDeck® Prime Roofboard FRX-G) "SECUROCK0 Roof Board" (Typeor "Ses "GAF S Glass -Mat Vapor Retarder" Roof Board"o} isoc anurate One or more plies "GAF® SA Vapor Retarder" self -adhered erlite/p Y Y Vapor Barrier (optional): lass fiber or polyisocyanurate or urethane or p layers erlite or wood fiber or g composite or phenolic, any thickness. Insulation: — One or more lay P of iso anurate composite or perlite/urethane composite or wood AS® Ply �„ o�Tri-PIy@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri-PIy® Ultra -Flexible ply Sheet: —Three or more plies Type G1 "GAFG Ply 6", fully adhered with hoot roofing asphalt. Sur acing: — Gravel. Incline: 2 LLC "DensDeck@ Roofboard" or 2. Deck: C-15/32 Georgia-Pacific Gypsum sum Co. Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georg r "DensDeck@ DuraGuard-N Roofboard" or minnimumSGMRX)ck United States GYP urate "DensDeck® Prime Roofboard ° or "SECUROCK@ Glass -Mat Roo. Boa (Typeof isocyan "SECUROCKO Roof Board" (Type FRX-G) lass fiber or polyisocyanurate or urethane or perlite/p Y erlite or wood fiber or g composite or phenolic, any thickness. Insulation: —One or more layers p of iso anurate comp @ultra -Flexible composite or perlite%urethane composite or wood ASO.fii p Y cY ' s Type Gl "GAFGLAS@ Ply 4" or "Tri-PIy@ ply 4" or "GAFGLA50 Flex Ply 6" or "Tri-P Y r Ca T''" Ply Sheet: —Three or more plies YP ply 6", fully adhered with hot roofing asphalt- 1 Surfaced Cap Sheet" or "Tri-PIy@ BUR Granule Cap Sheet" or"GAFGLAS® Ene gy Cap Sheet: —Type G3 GAFGLAS@ M asphalt Mineral -Surfaced Cap Sheet", fully adhered with hot roofing as Incline: 2 LLC "DensDeck@ Roofboard" or 3. Deck: NC Georgia -pacific Gypsum sum Co. Barrier Board (optional) — One or more layers minimum 1/4-in. thick,,minimum 1/4-in- or "DensDeck@ DuraGuardw Roofboard" or Board (Type SGMRX)ck United States Gyp "DensDeck@ Prime Roofb°ard e FRX o} isocyanumte or urethane or or "SECUROCKO Glass -Mat Roof Bo henoliG 2-�n. "SECUROCK® Roof Board" (Type erlite or wood fiber or glass fiber or p Y Composite or p Insulation (Optional): — One or more layers p osbe or wood fiber/polyisocyanurate perlrte/polyisocyanurate composite or perlite/urethane comp ® Ultra -Flexible maximum. e Gl "GAFGLAS@ Ply 4" or "Tri-PIy@ Ply 4" or -GA FGLAS@ Flex Ply 6" or "Tri-PIy Ply Sheet: — Two or more plies Type asphalt Ply 6", fully adhered with hot roofing P 1 Surfaced Cap Sheet" or "Tn-PIYO BUR Granule Cap Sheet" or "GAFGLAS® EnergyCap Cap Sheet: —Type G3 "GAFGLAS@ Miners as halt. Mineral -Surfaced Cap Sheet", fully adhered with hot roofing p Incliner 1 4_ Deck C-15/32 nailed to deck slipSheet (Optional): — Red rosin paper, wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with An thickness perlite or Insulation (Optional): — Y UL Classified insulation adhesive. a #80 UltimaTM' Base Sheet" OMG Inc. "OlyBond Fastening System" or any I Type G2 "GAFGLAS@ #75 Base Sheet" or'Tcalll fastened. ned,4475 ase Sheet" or "GAFGLAS Pl ®Ultra -Flexible Base Sheet. — One p Y YP Base Sheet", mechanically or "GAFGLAS@ Stratavent® Nailable Venting O p} 4" or GA FGI,45® Flex Ply 6" or "Tri y lies Type Gl "GAFGLAS@ ply or "Tri-Ply Y She or "GAFGLAS& EnergyCap''' ply Sheet: —One or more p � asphalt. @BUR Granule Cap Ply 6", fully adhered with hot roofingSheet" or "Tri-PIy Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap asphalt Mineral -Surfaced Cap Sheet", fully adhered with hot roofing Cote Roof Coating" or "TOPCOAT@ MB Plus Coating" or "United (optional): — "United CoatingsTM` TOPCOAT@ Energy al. el Roo Coating (op lied at a rate of 2-g / Coatings"'" Roof Mate MB Plus Coating" applied Incline: 3 @ #75 Base Sheet" or "GAFGLAS@ #80 Ultima"° Base Sheet" 5. Deck: NC "75 Base Sheet" "Tri-Ply Base Sheet" or "GAFGLAS@ Base Sheet: — One ply Type G2 "GAFGLASO a Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting or "GAFGLAS@ GLASt' Stratavent@ Perforated Venting Base Sheet", mechanically fastened or fully Stratavent® Nailable Venting Base Sheet" or GAF adhered with hot roofing asphalt. O PI 4" or"GAFGLAS® Flex Ply 6" or "Tri-Pl ®Ultra -Flexible Y Y ply Sheet- — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-PIy Y halt. BUR Granule Cap Sheet" or "GAFGLAS® EnergYCap'"' Ply 6", fully adhered with hot roofing asphalt. T. mP G3 "GAFGLAS® Mineral Surfaced Cap Shee o+ "Tri-Ply@ C�3tJ�TfG ,_ MIAMI DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) vivtv.miamidade.soy/economy GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The N iami Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for -quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Bat -Up Roof Systems for Wood Decks. ABE ING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state an LABELING: following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,.use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEAIENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1030.01and consists of pages 1 through 27. The submitted documentation was reviewed by Jorge L. Acebo. APPROVED NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 1 of 27 i ROOFING SYSTEM APPROVAL Category: Roofing Sub-Cate6ory BUR Material: Fiberglass Deck Tyne: Wood Maximum Design Pressure: -97.5 psf. TRADE NANms OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: FABLE 1 Test Product Product Dimensions Specification Description GAFGLAS' Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat. Tri-Ply® Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat GAFGLAS' F1exPly 6 GAFGLAS' #75 Base Sheet Tri-Ply®475 Base Sheet GAFGLAS' #80 Ultima"°Base Sheet GAFGLAS® Stratavent' Perforated Venting Base Sheet GAFGLAS' Stratavent'Nailable Venting Base Sheet Ruberoid® 20 Smooth Ruberoid' Mop Smooth Ruberoid® Mop Smooth 1.5 Ruberoid® Mop Plus Smooth Ruberoid' HW 25 Smooth 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat. 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Wide with fiberglass mat. 39.37(1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Wide with fiberglass mat. 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Wide with fiberglass mat. 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic perforated venting base Wide sheet reinforced with fiberglass mat. 39.37 (1 meter) ASTM D4897 Smooth surfaced asphaltic nailable venting base Wide sheet reinforced with fiberglass mat. Bottom side surfaced with granules. 3937" (1 meter) Wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide 39.37" (1 meter) wide ASTM D6163 SBS polymer -modified asphalt base or anchor sheet reinforced with a fiberglass mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTMD6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6163 Smooth surfaced torch applied SBS base or anchor sheet reinforced with a fiberglass mat. NOA No.: 18-0919.07 MIAMt•DADE COUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 2 of 27 TRADE NAmEs OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Ruberoid® HW 39 37" (1 meter) ASTM D6164 Smooth surfaced torch applied SBS base or anchor Smooth GAFGLAS* Mineral Surfaced Cap Sheet TriPly® BUR Granule Cap Sheet GAFGLASO EnerayCap'"' Mineral Surfaced Cap Sheet Topcoat® Surface Seal SB Topcoat® Membrane Topcoat® MB Plus wide sheet reinforced with a polyester mat. 3937" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Wide with fiberglass mat. 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Wide with fiberglass mat. 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Wide with fiberglass mat Cap sheet is factory coated with TOPCOAT® EnergyCote' Elastomeric Coating. 5 or 55 gallons ASTM D6083 Solvent -based thermoplastic robber sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. 1, 5 or 55 gallons ASTM D6083 Water -based elastomeric coating . 5 or 55 gallons Topcoat® FireOut" 5 or 55 gallons Fire Barrier Coating VersaShield*Fire- 12" x 100' rolls Resistant Roof Deck Protection VersaShield' Solo` 42" roll wide, 100 Fire -Resistant Slip fL Sheet Proprietary Water based, low VOC primer designed to block asphalt bleed -through - Proprietary Low VOC, water based fire barrier coating_ ASTM D226 Non -asphaltic, fiberglass reinforced underlayment and/or fire barrier ASTM D146, D828, D4869, D6757 Topcoat® 1, 5 gallons or TAS 139 F1exSealTm 1 qt. tube Non -asphaltic, fire resistant fiberglass underlayment Solvent -based elastomeric sealant. NOA No.:.18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 3 of 27 APPROVED INSULATIONS: TABLE 2 M[anufactarer Product Name Product Description ('With Current NOA) EnergyGuardT' Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard" Tapered Polyisocyanurate foam insulation GAF Polyiso Insulation EnergyGuard- Ultra Polyiso Glass -faced polyisocyanurate foam insulation GAF Insulation EnergyGuard7 RA Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuard, RA Composite Polyisocyanurate foam insulation with high GAF Polyiso Insulation density fiberboard or permalite EnergyGuard7 RH Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuarda-" RH Tapered Polyisocyanurate foam insulation GAF Polyiso Insulation EnergyGuard" RN Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuarr Perlite Roof Perlite insulation board GAF insulation EnergyGuard' Perlite Recover Perlite recover board GAF Board Securockc Gypsum Fiber Roof Gypsum board United States Gypsum Corp. Board Securoce Glass Mat Roof Glass faced gypsum board United States Gypsum Corp. Board Structodek' High Density Fiber High density fiberboard Blue Ridge Fiberboard, Inc. Board Roof Insulation DensDecke Prime Roof Board Gypsum board Georgia-Pacific Gypsum LLC DensDecO Roof Board Gypsum board Georgia-Pacific Gypsum LLC NOA No.: 18-0919.07 CMjAM�1,DAED)EC= Expiration Date: 11/04/23 • Approval Date: IV08118 Page 4 of 27 APPROwD FASTENERS FABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-Tec' #12 Fastener Phillips head, modified #12 x 8" max. GAF buttress thread, pinch point, length, #3 carbon steel fastener for use Phillips head. in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. 2. Drill-Tec'a' #14 Fastener Truss head, self -drilling, #14 x 16" GAF pinch point, high thread max. length, fastener for use in steel, wood #3 Phillips or concrete decks. head. 3. Drill-Tec' ASAP 3S . Dull-Tec•`' #12 Fastener with See GAF Drill-Tec' 3" Standard Steel components Plate. 4. Drill-Tec' 3" Steel Plate Round Galvalume® steel 3" Round GAF stress plate with reinforcing ribs and recessed for use with Drill-Teca' fasteners. 5. Drill-Tec"' 3" Standard Steel Galvalumel coated steel 3" Round GAF Plate stress plate for use with approved Drill-Tec'°' fasteners. 6. Drill -Tee' AccuTrac®Flat A2-SS aluminized steel plate 3" square; GAF Plate for use with Drill-Tec° .017" thick fasteners. 7. Drill-Tec'a' AccuTrace Galvalume' steel plate with 3 " square; GAF Recessed Plate recess for use with Drill- .017" thick Tee' fasteners. 8. Drill-Tec 3 in. Ribbed Round Galvalume' plated 3" Round GAF Galvalume Plate (Fiat) steel stress plate with reinforcing ribs for use with Drill-Tec' fasteners_ NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/19 Page 5 of 27 EVIDENCE SUBMITTED: Test A6ency Test ldentifer Description Date Factory Mutual Research Corp. 3014547 4470 05/22/03 3029832 4470 05/11/07 3033135 4470 11/24/08 3034312 4470 04/09/09 3036980 4470 08/14/09 3038278 4470 11/18/1I 3040738 4470 11/16/10 3041769 4470 05/26/11 3042887 4470 11/14/11 3042905 4470 01/10/12 3046081 4470 02/13/13 3046388 4470 09/24/12 3047636 4470 08/08/13 ODOA8.AM 4470 07/09/99 OD1A8.AM 4470 07/29/94 OY9Q5.AM 4470 04/01/98 1B9A8.AM 4470 09/04/97 2B8A4.AM 4470 07/02/97 3B9QLAM 4470 01/08/98 3D4Q2.AM 4470 05/30/97 797-03221-267 4476 09/27/07 797-03825-267 4470 07/21/08 797-10228-267 4470 01/23/15 UL LLC R1306 UL 790 08/21/18 PRI Construction Materials GAF-122-02-01 TAS 139 05/07/06 Technologies, LLC GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-01Rev ASTM D6083 12/16/10 GAF 276-02-02 ASTM D226 11/15/10 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF 315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF417-02-01 ASTM C1289 05/28/13 GAF-464-02-01 ASTM C1289 10/22/12 GAF-464-02-01 ASTM C1289 02/06/14 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-549-02-01 TAS 114 08/08/14 GAF-549-02-02 TAS 114 08/08/14 GAF-559-02-01 TAS 117(B) 09/30/14 GAF-559-02-04 ASTM D 1876 10/01/14 GAF-559-02-05 ASTM D 1876 10/15/14 GAF-559-02-06 TAS 114(H) 10/02/14 GAF-559-02-07 ASTM D 903 10/02/14 GAF-559-02-08 ASTM D 903 10/02/14 NOA No.: 18-0919.07 M�AMI-DADECOUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 6 of 27 � 5 � • EVIDENCE SUBMITTED: (CONTESTUED) Test Agency Test Identifier PRI Construction Materials GAF-559-02-09 Technologies, LLC GAF-559-02-11 GAF-559-02-12 GAF-559-02-13 GAF-559-02-14 GAF-559-02-15 GAF-559-02-16 GAF-559-02-18 GAF-559-02-19 GAF-628-02-01 IRT of S. Fl. Trinity I ERD Dynatech Engineering Corporation Atlantic & Caribbean Roof Consultants, LLC 02-005 02-014 C8500SC.11.07 G30250.02.10-3 R2 G31360.03.10 G33470.01.11 G34140.04.11-2 G34140.04.11-4-R2 G34140.04.11-5-R3 G36780.07.11 Rl G40630.01.14-1 G40630.01.14-2A G40630.01.14-2A-1 Rl G43610.01.14 G6850.08.07-1 SC6870.08.14-R1 SC9700.08.15 Rl SC10680.05.16 SC13105.03.17 Rl M482.02.95-1 I 1-053 Description ASTM D 903 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 ASTM C1289 TAS 114 TAS 114 TAS 117 ASTM D3909 ASTM D6164 ASTM D6164 ASTM D6163 ASTM D6401 ASTM D4897 4470-TAS 114 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D3909 ASTM D3909 ASTM D3909 ASTM D2178 ASTM D6163 ASTM D6164 TAS 114 TAS 114 Date 10/02/14 10/14/14 10/14/14 10/15/14 10/15/14 10/15/14 10/15/14 10/15/14 04/16/15 05/31/16 01/18/02 03/22/02' 11/30/07 06/03/15 03/31/10 11/16/11 04/25/11 06/04/15 06/04/15 07/18/11 01/06/14 01/07/14 04/10/14 01/22/14 08/13/07 09/04/14 8/31/2015 5/10/2016 3/23/2017 09/01/95 08/12/11 NOA No.: 18-0919.07 MIAMI•DADE COUN7YM Expiration Date: 11/04/23 ...l Approval Date: 11/08/18 Page 7 of 27 Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(1): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat' FireOut"" Fire Barrier Coating, VersaShield'Fire Resistant Roof Deck (optional) Protection, VersaShield' Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Base sheet: GAFGLAS® #80 Ultimate' Base Sheet, Stratavent' Nailable Venting Base Sheet, Ruberoid® 20 Smooth, Ruberoid® SBS Heat -Weld' Smooth or Ruberoid® SBS Heat -Weld' 25 base sheet mechanically fastened to deck as described below; Fastening GAFGLAS`I Flex Ply" 6, GAFGLAS® #75 Base Sheet, TriPly® #75 Base Sheet or any of Option #1: the above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field (Maximum Desia-n Pressure —52.5 psf. See General Limitation #7) Fastening GAFGLASO #80 Ultima'N` Base Sheet, Ruberoid'20 Smooth or Ruberoid®Mop Smooth Option #2: attached to deck with approved 1 %" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. of the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Desib-7z Pressure —60 psf. See General Limitation #7) Ply Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply' Ply 4 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLASII Mineral Surfaced Cap Sheet, TriPly® BUR Granule Cap Sheet or GAFGLAS®EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 IbsJsq. installed per manufacturer's installation instructions. Spacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbsJsq. and 3001bsJsq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat®Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 18-0919.07 M"I•DADECOUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 21 of 27 WOOL) DECK SYSTEM LEMTATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGI-AS® Flex Ply' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'%" DensDeck' Roof Board or %" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL L► .11 UTATIONS: 1. Fire. classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 IbsJsq. Note: Spot attached- systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (FD value of 2751b£, as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 If insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant maybe submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, RegisteredArchitect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designedpressure limitation listed shall be applicable to all roofpressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF TIES ACCEPTANCE NOA No.: 18-0919.07 pfiAMbDADEcouNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 27 of 27