REV-19-2364Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Issue Date:
Location Address Parcel Number
358 NE 100TH ST, Miami Shores, FL 33138 1132060135430
Contacts
Permit No.: REV-10-19-2364
Permit Type: Revision
Work Ciassi, cation: Roofing
Permit status: Applied
Expiration: 04/05/2020
GREGORY MUZII Owner T&S ROOFING SYSTEMS INC. Contractor
358 NE 100 ST, MIAMI SHORES, FL 331382421 LOUIS TOLEDO
1461 NW 23 ST, MIAMI, FL 33142
Business: 3052652654
Other:3057727954
Description: ADDING TILE REPAIR Valuation: $ 1,200.00 Inspection Reguests:
305-762-4949
Total Sq Feet: 20.00
Li � I I
Fees
Amount
Payments
Date Paid Amt Paid
Revision: Major Change of Plans
$90.00
Total Fees
$99.00
Scanning Fee (Manual)
$9.00
Check # 37005
10/09/2019 $99.00
Total:
$99.00
Amount Due:
$0.00
Building Department Copy
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating construction and zoning. Futhermore, I authorize the abov eclractor to do the work stated.
�/ /6-q- zoi l q
Authorized Signature: Owner / Applicant / Contractor 4--"'AgeJ Date
October 09, 2019 Page 2 of 2
Miami Shores Village
Building Department
q 10050 N.E.2nd Avenue, Miami Shores, Florida 33138
�\ Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING
PERMIT APPLICATION
❑BUILDING ❑ ELECTRIC ❑ ROOFING
RECEIVED
OCT 0 8 2019
FBC 20 N' 1L
Master Permit No.� r lg —
Sub Permit No.yzeyrI1 �f
' I 0 Q` dL3�
❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: � U Nf 100 _ _�t
I
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#: 1V Y[66" 015— S 3O Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee
e7Simple
�Tiitleholder): UI t
Address: 3 S D I l 1.le160 5
City: UIVIVVII
Tenant/Lessee Name:
Email
e S State:
Phone#: �)g jj-z —
0M
CONTRACTOR: Company Name:
I' '�1
Phone#:
Q
Address:'
!NW
Z Srt
City: 1 I
State: '�
Zip: 331�
Qualifier Name:
Phone#:
State Certification or Registration #:
!I
C i� �U L
Certificate of Competency #:
DESIGNER: Architect/Engineer:
Phone#:
Address:
City: State: Zip:
Value of Work for this Permit: $ 2U' Q Square/Linear Footage of Work:
Zd
Type of of Work: ❑ Addition ❑
Alteration ❑ New
Repair/Replace
❑ Demolition
Description of Work: 1 I1 lLP,11fy
Specify color of color thru tile:
Submittal Fee $
Scanning Fee $
Technology Fee $_
Structural Reviews $
Permit Fee $
Rad
CCF $_
on Fee $ DBPR $ Notary $
Training/Education Fee $ Double Fee $
Bond $
(Revised02/24/2014)
TOTAL FEE NOW DUE $ . CA
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zi
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
ER or AGENT
The foregoing instrument was acknowledged before me this
day of 20 I q by
C1 A Mj who is personally known to
me or who Was produced U gAGSL as
identification and who did take an oath.
NOTARY PUBLIC:
Sign
Print:
"e1 e1'V MA'`'t- 11 Iq
Seal: '° " DANIELGONZALEZ
:.• MY COMMISSION 0 GG 250277
- R opt EXPIRES: August 19, 2022
Bonded 1DN NotaryPOk Wdemftwx
****************
APPROVED BY
Signature
CONTRACTOR
The foregoin �*s/trument was acknowledged before me this
(— day of 20 1 �1 by
who is personally known to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign,
Print:
Seal:
***************
Plans Examiner
Structural Review
V
My Com^i Exo,res Nov 3 2C20
******************************
Zoning
Clerk
(Revised02/24/2014)
•••• •••• •••••
•••••• •• • •••••
ANINk
COPY
• • • • ••••••
• • OFFICE
`i
�o6 . 1
OCT o s
STA��j"�'"'�-
Section AB
M IAM NDIADE
"Delivering Excellence Every Day"
Miami -Dade County HVHZ Electronic Roof Permit Form
Section A (General Information)
Master Permit No: Process No:
Contractor's Name: T AND S ROOFING
Job Address: 358 NE 100 ST
Roof Category
0 Low Slope ❑ Mechanically Fastened Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles
❑ Sprayed Polyurethane Foam ❑ Other:
:060%
• •000••
...... .... ......
Q Mortar/A ft§§ vp•Set Tiles
DoWaod Shi "046hakej,,,,.
......
. . . . ......
Roof Type
ElNew Roof 0 Re -Roofing ElRecovering 0 Repair ElMaintenance
Are there Gas Vent Stacks located on the roof? ❑ Yes 0 No If yes, what type? ❑ Natural ❑ LPGX
Roof System Information
Low slope roof area (ft.2) 900 1 Steep Sloped area (ft.2) 20 Total (ft.2) 920
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
Perimeter Width (a'): E____::1 Corner Size (a' x a'):E::�
Tile Roof System
MIAMI•DIADE
03 Miami -Dade County HVHZ Electronic Roof Permit Form
Section D Tile Roof System
"Delivering Excellence Every Day"
Roof System Manufacturer: CERAMICA VEREA S.A
Notice of Acceptance Number (NOA): 17-0727.07
Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations):
: • • • •
P 1: 39.1 P 2: 68.1 P 3: 100.7 ......
....
Maximum Design Wind Pressures, (From the NOA Specific system): 69.21 psf • • • • •.
. • • • • •
Fill in the specific roof assembly components. If a component is not required, insert not applicable (rj/aj in
the tea box.
Deck Type: --5/8" PlywQad;•;
Roof Slope: "/12"
Roof Mean Height: 15 ft.
Method of Tile Attachment:
—Adhesive, Large Paddy Polyfoam Polypro--
Alternate Method of Tile Attachment per NOA:
Drip Edge Size & Gauge: --3" face 26 ga -
Drip Edge Material Type: Galvinized Metal --
Optional Insulation: • • • • • •
Optional Nailable Substrate:
Optional Nailable Substrate Attachment:
Basesheet Type:
30 ASTM TYPE II
Fastener Type for Basesheet Attachment:
1 1/4 RS NAILS 6" OC AND 12" FIELD
Tile Underlayment (Cap Sheet ) Type:
BORAL TILE SEAL
Tile Underlayment Attachment Method:
SELF ADHERED
Drip Edge Fastener Type: 1 1/4 RS NAILS Tile Profile:
CARIBBEAN " S"
Hook Strip/Cleat gauge or weight: -- Select Hook Strip --
.sees.
eeeee•
Section E
"Delivering Excellence Every Day"
Miami -Dade County HVHZ Electronic Roof Permit Form
Section E (Tile Calculations)
Method 1 "Moment Based Tile Calculations Per RAS 127"
For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf valuec are Y
greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceeieble. : • • • •
Y •
• • • • • •
•
P 1 39:9
x x.300
= 11.73
_ Mg: 5 34
= Mr1: 6 39-- < 59.21...
YY Y Y.Y�
Y •
•YYYY• •YY•
N'f!;MIP
Y
•
•YYYYY
:....:
_
P 2: 68.1
x �, • 300-•YYYY•
= 20.43
_.-
_ Mg: 5.34
= Mr2: 15 09 < 59.21
•....•
NOA•lelf • • • •
• •; •'.
P 3: 100.7
x X.300
= 30.21
- Mg: 5.34
= Mr3: 24.87 59.21 1
1 • Y•Y• ••
NI A.Mf • • • • •
.....
' • • • �'
•YYYY• !
•
Method 3 "Uplift Based
Tile Calculations
Per RAS 127"
•• • . •• • •
For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equaltd M2 Fr values, for
each area of the roof, then the tile attachment method is acceptable.
P1:® x1:
=®xw:
=®-W:�=®
xCos 0:171=Fr1:
:5
NOAF'
P2: x1:
=
xw:
= -W:
=
xCos 0:171=Fr2
:5
NOAF'
P3:
x1:
=
xw:�=
-W:
=
xCos 0:El=Fr3:
5
NOAF'
Where to Obtain Information to complete tile calculations
Description
Symbol
Where to Find
Design Pressure
P1 or P2 or P3
Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional
engineer based on ASCE 7.
Mean Roof Height
H
Job Site
Roof Slope
9
Job Site
Aerodynamic Multiplier
x
Product Approval (NOA)
Restoring Moment due to Gravity
Mg
Product Approval (NOA)
Attachment Resistance
Mf
Product Approval (NOA)
Required Moment Resistance
Mr
Calculated
Minimum Attachment Resistance
F'
Product Approval (NOA)
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval (NOA)
Tile Dimensions
I =length
w =width
Product Approval (NOA)
MIAMFDiADE
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Ceramica Verea, S.A. •
Lanza S/N,
15685 Mesia (A Coruna) -Spain • • •
SCOPE: �•••••
.... .... . .
This NOA is being issued under the applicable rules and regulations governing the use of colMfltl;tion matMffis. The ".
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Pro( cl tontrol'S��ction to �e� • •
used in Miami Dade Countyand other areas where allowed b the Authority Having Jurisdi• • • J . • • • • •
Y h' g S�4�lAH) .'
. .
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Counti Product Co**trot Section, • • • •
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve t gJ?9l: to hive this :"":
product or material tested for quality assurance purposes. If this product or material fails to perform in the.3aoepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Caribbean "S" Clay Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 5.
The submitted documentation was reviewed by Freddy Semino.,
NOA No.: 17-0727.07
MAWDADE COUNTY
� . Expiration Date: 07/05/23
Approval Date: 07/05/18
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles • • •""' ......
Material: Clay " •
...... .... ......
1. SCOPE •••• �•••••
.... ....
This system using Caribbean "S" Clay Roof Tile One Piece Tile, as manufactured by.CrIlmica Varea,.. S.A.0.•..
and described in Section 2 of this Notice of Acceptance. For locations where tbe.Prgsture raggi%ments,.s •
determined by applicable Building Code does not exceed the design pressure values ole"aed by calculations in . •
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be doge..%
as a moment based system. 000 .
00:000
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Caribbean "S" Clay Roof Length: 18.75" ASTM C1167 High profile clay roof tile for direct deck
Tile, One Piece Width: 10.75" Type I applications.
Thickness: ''/s" Grade 2
Head -lap min. 3"
Exposure max.
15.75"
Trim Pieces Length: varies ASTM C 1167 Accessory trim, clay roof pieces for use at hips,
Width: varies rakes, ridges and valley terminations.
2.1 MANUFACTURING LOCATION
2.1.1. Mesia (A Coruna) Spain
2.2 EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
American Test Lab of South RT0309.01-18 ASTM C 1167 04/29/18
Florida
American Test Lab of South RT0309.02-18 Static Uplift Resistance Testing TAS 04/26/18
Florida 101 Adhesive set tile system.
NOA No.: 17-0727.07
Mu►MFDADeCourrrr Expiration Date: 07/05/23
Approval Date: 07/05/18
Page 2 of 6
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106.
......
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory;.o 0 form q�arterly test Ill •
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the aiuj(j Pg Codq.CigmpHance
• •
Office for review. ...:.. •
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Apt fic ations Sigildtrils listed+ •
section 4.1 herein. • • . .
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the'taof slop6nn)ess stated....
otherwise by the underlayment material manufacturers published literature. •
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in cif?t 'ahce with •
applicable building code. • •. ......
.. .
3.7 All products listed herein shall have a quality assurance audit accordance with the Florida Hnrlding Code •
and Rule 61 G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Caribbean "S" Clay Roof Tile, One Piece Roofing Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lbf.)
Length-1 (ft)
Width-w (ft)
Caribbean "S" Clay Roof Tile
6.589
1.56
0.896
Table 2: Aerodynamic Multipliers - X (ft3)
Tile % (ft3)
Profile Direct Deck Application
Caribbean "S" Clay Roof Tile 0.30
Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf.)
Tile
3":12"
4":12"
5":12"
611:12"
7":12" or
Profile
greater
Caribbean "S"
Direct Deck
Direct Deck
Direct Deck
Direct Deck
Direct Deck
Clay Roof Tile
5.58
5.47
5.34
5.19
5.03
1 Data noted in Table 3 is for installation with a 3" the headla .
NOA No.: 17-0727.07
MLAMEDaoeCouExpiration Date: 07/05/23
Approval Date: 07/05/18
Page 3 of 6
Table 6: Attachment Resistance Expressed as a Moment - Mf (W-10.)
.'••••
for Single Patty Adhesive Set Systems Adhesive Set Systgr9199:.0
•'•' "•
Tile
Tile
Att61Ctftfignt
...
see*, •
Profile
Application
Restfflhce
' • • • 600
Caribbean "S" Clay Roof Tile
ICP Adhesives Polyset AH-160,9
1•
• . 9
Adhesive Set'
•
***foe
1 Large paddy placement weight 22.2 grams of ICP Adhesives and Sealants, Inc.'s ICP A heg'As Pol
et H-160
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed
below, or following statement: "Miami -Dade County Product Control Approved".
CARIBBEAN 66S"
MADE IN SPAIN * VEREA
(LOCATED ON THE BOTTOM SIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to
properly evaluate the installation of this system.
NOA No.: 17-0727.07
MAMMADE COUNTY Expiration Date: 07/05/23
Approval Date: 07/05/18
Page 4 of 6
18.3J4'
PROFILE DRAWING
10.314'
Ceramica Verea S.A. Caribbean "S" Clay Roof Tile
END OF THIS ACCEPTANCE
NOA No.: 17-0727.07
Expiration Date: 07/05/23
Approval Date: 07/05/18
Page 5 of 6
......
....
......
....
....
. .
....
....
.....
......
.. .
.....
.. ..
.. .
......
......
.
.
. .
. .
%
......
....
. .
..... .
*000
NOA No.: 17-0727.07
Expiration Date: 07/05/23
Approval Date: 07/05/18
Page 6 of 6
MIAMI
rk"712,11 in
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) wrvvw.nuamidade.Lov onomy
ICP Adhesives and Sealants, Inc.
12505 NW 44" Street +• • • •
Coral Springs, FL. 33065
SCOPE: �•�� •�•� � •
• •
.... .... .....
This NOA is being issued under the applicable rules and regulations governing the use of Qwkskv ction nwateriils. T11L*' • •
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Proud 40ontror Section to lid'O:*
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdictmifi f WJ). '
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Counlj Product Centrot Section. • • •
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the cig�tto havT V1 yroduc't
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted i'iitAner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the. words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
:...:. .....
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and *al4fiV, Incas described •
in this Notice of Acceptance. For the locations where the design pressure requirements, as deMrmilied by&aNlaable „•
building code, do not exceed the design pressure values obtained by calculations in complian� WiTh Roofing. •
Application Standard RAS 127. For use with approved flat low, and high profile roof tiles $to 1s using " � • •
Adhesives Polyset® AH-160. '
.... .... .....
...... 000000 .....
PRODUCTS MANUFACTURED BY APPLICANT: •
.. .. .. . ......
• . • • • • . •
Product Dimensions Test Product Ddsetiptiou . • • • : •
Specifications •
ICP Adhesives N/A TAS 101 Two component polyuredlane fvgil , jdhesive •
Polyset'AH-160
ICP Adhesives Foam N/A Dispensing Equipment
Dispenser RTF1000
ICP Adhesives ProPack' N/A Dispensing Equipment
30 & 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset' AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball, TX.
PHYSICAL PROPERTIES:
Property Test
Density ASTM D 1622
Compressive Strength ASTM D 1621
Tensile Strength ASTM D 1623
Water Absorption ASTM D 2127
Moisture Vapor Transmission ASTM E 96
Dimensional Stability ASTM D 2126
Closed Cell Content ASTM D 2856
Results
1.6 lbs./ft.3
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Ft2
3.1 Perm / Inch
+0.07% Volume Change @ -40' F., 2 weeks
+6.0% Volume Change @1580F., 100% Humidity, 2
weeks
86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
MIAMI•DADE COUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Ageney
Test Identifier
Test Name/Report
Date
Center for Applied Engineering
#94-060
TAS 101
04/08/94
257818-IPA
TAS 101
12/16/96
25-7438-3
SSTD 11-93
10/25495
25-7438-4
••••••
25-7438-7
SSTD 11-93
• •
•
11J0?/95
25-7492
SSTD 11-93
".,...
1`34245
Miles Laboratories
NB-589-631
ASTM D 1623
• • • •
02T0 r/94
Polymers Division
• •
• • • f
Ramtech Laboratories, Inc.
9637-92
ASTM E 108
047%;3
:09.
Southwest Research Institute
01-6743-011
ASTM E 108
•
"•
1 iAVi4
01-6739-062b[1]
ASTM E 84
'..'
0/166i5
. •
Trinity Engineering
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
s.
srs•••
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset AH-160.
2. ICP Adhesives Polyset AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the ra'si4drae value
determined in compliance with Miami -Dade County Roofing Application Standards RAS•f27. The adhesive • 0 • •:'
attachment data is noted in the roof tile assembly NOA. •
...... .... ......
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance M&Rbofing Application: •
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction andM?ritenanceoB'bbklet. •
.... .... .... .
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by q Adhesives and .. ;
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applica#ors•to the au%Ao having .. .
jurisdiction.
......
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required befcp v;V4icatiop
of any adhesive. The mix ratio between the "A" component and the "B" component shzybe maintainedbetweV • • •;
1.0-1.15 (A): 1.0 (B). ....
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP
Adhesives ProPack® 30 & 100 dispensing equipment only.
7. ICP Adhesives Polyset AH-160 shall not be exposed permanently to sunlight.
S. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches�'b3'
...
Flat Profile
#2
10-12 sq. inches
Low Profile
#2
12-14 sq. inches ...:..
3Q
High Profile
42
0900
17-19 sq. inches
lid 11Soso
*990 •
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at •
: • • 12 graUmvp paddy+ • •
head of tile 9-11 sq. inches at •
• • • • • • • •
overlap : ":'
•
: '
• . • 090.
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal:
• • 17 grams per bead
edge) 20-25 sq. inches each •
• • •
bead
ego*
*so*
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
MIAMI-DADE COUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 2
OWIhr¢y9h01411-FOIM*ht NddyiAMlRR1h ►W
.'J
T 'dui. Al
JIn`a 2in
Eawtonn•`
21ft�-
huh;t �f f�C�
cave Elelure-
Nsilthrough plasticement
$when nquiredl
Batteml optional
gaeneaaih
Fag. C6 iw
Ftpcia
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm.) x 10" (254 mm.) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
••••••
2. At the second course, apply a g imunf 2" (50.8mm)* •':
x 7" (177.8 mm) x 1" (25.4•n1m)%am paddy onto the •
underlayment positioned a0se* : hown under t�0 •
strengthening rib closest to t%e gverlock p f J) a tile ; • • •';
being set.
.... 0 000000 .....
•••••• •• • •••••
• • .
3. Continue in same manner. Wum approximately 10"• • • • • •
(64.5 cm2) - 12 (77.4 cm2) pq>s4it-.inch adhesive •.
contact with the underside bf the Tile. ; ... ; . • • • • • •
• •
• • • . • • • •
• • •
••••
Medium Profile / Double Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
nun) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 em'-) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm.) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
Wall thmough pbstk cownt
twbe'n required)
'.
hastens optional
Y Env eCau*se— r 6 x 'fasda
low pan.
1y� x ! 'E,mr ctostrnr
-'t' V<{f` ibripedpe
High Profile / Single Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm') square inch adhesive contact with the
underside of the tile. •
At the second course, apply-agmAmum.7-t-1Q.8mm) '.
x 7 (177.8 mm) x 1 (25.4MI foam paddy onto the
•• ••• •
underlayment positioned as W : n under the pan 6 •so* • • •
portion of the tile closest to"e•9verlock p f 14C tile .....
being set. $66094.`
• • • • •
Continue in same manner. kmwo approximately 17" •.
(109.7 cm2) - 19 (122.6 cm:) square inct,;aC ive •goes'
contact with the underside Qf th tjle. ' : • • • •
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
Mil through plasticeement Paddy (between tiles)
iwhen requued)
nttens optional C.
I. Paddy [under tile)
Singlepaddy
%%%own tit tile
L
x4
5ule,ad ` +:
+order tie
Single paddy
onunderla mt
in
ym �2x4.
y o fin �, 1
` i in Feria
--Faveclosure
Flat/low Profile Tile
Wag through plastic onnent Single paddy under tile
(when required)
Paddy ibetWeen ales)
Battens Paddy [under tile}
o)rtior 31
Single
7 1
on top
�i
o
a:4in.
2s4in+-.
-�
Single Paddy on "
undeffulneent +�+
10s1. `> 1in.
Ean Closure
Eave Course Fascia
Mediurn ProfileTile
MIAMI•DADE COUNTY
-Wro m
On the eave course only, apply a minimum 2" (50.8
mm.) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in' (109.7-148.4 cm) of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) 3C4" ji01.6 JAT!:�' (25.4.....
mm) foam paddy onto the0dnderlaymji0-j .t below . •
the second course line pdsriMW foamrpaddy • • • • - -
under the strengthening MTor flat tile, of under tl% • • •
pan portion of the tile, cloys. § Flo the wUe'rlock for' •
the second course tile to jr,�Vtalled. nsl;e • .:. •
approximately 8-9 in- (5JA-W.1 cm) al�Aesiv q, . . . . •
contact with the underside 4the tile. • •
(Instructions continued on ne fpake) • • • • •
•..•
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Mail through plastic ce
Sngle paddy under file
jwhen required)
Paddy 4between tiles)
Battens ••-
optional
Paddy lunder.tile)
� singlepaddy
r�
*nundedryme
t,-+
'4x4in.
.�
Single 2x4in.
paddy on �.
top ofiffe• `.
Eave Course
Fasda
Weephole
loin. tin.
Eavedowre
Drip edge
High Prance Tile
3. Also apply a 2" (50.8 nun) x 4" (101.6 mm) x 3/4"
(19 nun) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm) - 11 (71cmz) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm') - 9 (58.1 cm) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
••••••
000000
• • •
•• • ••••
000000 • • •
•
•••• ••••••
.... .... .....
. • • • • • 0000000
..
•• •• •• • ••••••
• • • • • • •
• 00
• • • • • • • • •
•
• .... .
. .
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications
In contact with the pan the (when required)
2) Tum covers upside down. Place adhesive In
to 1 in.from outside edge of cover tile.
Then install the tile. Ensure 20 to
25 sq. in. contact area.
IUnderlayment
(rooter shown)
Fascia
Remove top portion of the rave course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cmz) — 70 4451.6 cmz)
square inch adhesive cunt aot with V lMrsidee e • • • •
of the pan tile. •• ' •••••• ••
•
3. Turn covers upside down 6*1 Sosing the lmdersidr. a 0 •
of the tile. Apply a mia`m* m 1" (25 4"Mu) x I (T • • • •
(254 mm) bead of adheSive•c�irectly on tree inner •
edge of each side of thrdp�r tile. Lppg • *fee * •
approximately 3/4" (19arkva)eto 1" (25..1 mm) ••
from the outside edge of tree tile, inivard.� free o£ .. e ; •
foam to allow for exp$nsiQn•
4. Turn cover tile over after foam is apWbti and
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cm2) square inch
contact area on each side of the cover file to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
M IAM EDiADE
/JRRPrf
MIAMI-DADE COUNTY
ha WAMW
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.►niamidade.gov/economy
Boral Roofing LLC.
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). , ,
• , :•••••
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County*Wdttt Conggp Section • •
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve tlta to have"__ .,.,; •
product or material tested for quality assurance purposes. If this product or material fails to perferm in the aoeepted •
manner, the manufacturer will incur the expense of such testing and the AHJ may immediatQly*&Ivpke, n4RlfP5%pr •
suspend the use of such product or material within their jurisdiction. RER reserves the right to evoke this* Weptancd o: • •
if it is determined b Miami -Dade County Product Control Section that this product or matey �laAs to m elAo "• • •
Y tY • •i .. . 000090
requirements of the applicable building code. ,,,,,, 00
This product is approved as described herein, and has been designed to comply with the Flonda•84ildingCod; ,,,,: •
including the High Velocity Hurricane Zone of the Florida Building Code. : • • : • • • • • ,
DESCRIPTION: BORAL TileSeal
.. . . • • •
••••
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This new NOA consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0502.03
MIAMMADE COUNTY
... � � Expiration Date: 08/02/23
Approval Date: 08/02/18
Page 1 of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS
PRODUCTS DESCRIPTION:
Test
Product
Product Dimensions Specification
Description ,
BORAL TileSeal 36" x 36'
rolls TAS 103
SBS self -adhering aspjialt ftet material with a'... •
36" x 72'
rolls ASTM D 1970
white glass re-enforced*6olye*ster sxrfat iNg fabric;
for use as an underlay"ej4j slopelrQof
assemblies. • • • • •'
.... ....
Boral Citadel Plus 36" x 72'
rolls ASTM D1970
. .
... ......
SBS self -adhering asp .�t„�et mat;"jiwith a,,;,, •
poly film -facer; for useesamid-ply.;rOdcrlaymQnt....
in sloped roof assembtca.: • •
. . . . ......
MANUFACTURIGN LOCATION:
• • • • • •
1. Brentwood, NH.
'•"
2. Houston, TX.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report Date
PRI Construction Materials
OCF-356-02-04
ASTM D1623 07/25/18
Technologies, LLC.
OCF-356-02-02
TAS 103 07/24/18
OCF-356-02-01
ASTM D1970 07/26/18
OCF-424-02-04
ASTM D1623 07/25/18
OCF424-02-01
ASTM D1970 07/25/18
OCF-424-02-03
TAS 103 07/25/18
Trinity ERD
BRLRF-SC16810.11.17 ASTM D 1876 11/28/17
NOA No.: 18-0502.03
Expiration Date: 08/02/23
Approval Date: 08/02/18
Page 2 of 4
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated
Deck Description: 15/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet:
One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" head lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps
and two staggered rows 12" o.c. the field of the roll.
......
Ply Sheet
Apply one layer of Boral Citadel Plus over Base sheet as per currenPa`pprbval. • • • • • • • •
(Optional):
• • • • • • 0000
••• 660000
Membrane:
......
.... .... . .
One or more plies of BORAL TileSeal Underlayment with a minin?44 3;'•head 4.4ryd'
• • • • •
minimum 6" end lap. Place the first course of membrane parallel tathe nave, rolling the 00000 •
membrane to obtain maximum contact. Remove the release membmne as the membrane is • • • • • •
applied. Vertical strapping of the roof with BORAL TileSeal UndQdt�ptnt is acceptable. All •,
end laps and laps without black selvage area shall be sealed under 1'ap using an TUSAodified • • • • •
mastic. 000 0 • • • • • •
•• • • • • • •
. .
Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to
deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side
laps. No nails or tin caps shall be exposed.
Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof
Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies.
NOA No.: 18-0502.03
Expiration Date: 08/02/23
Approval Date: 08/02/18
Page 3 of 4
I
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable
Building Code.
3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.
4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be
applied over a roofing Base/Anchor sheet underlayment. ; • • • • • • • • • • •
5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer tien A30 daY9 of*. • •
application. ••••••• •••• ••••••
6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when VIVO are loaded directl & • • • •
to the BORAL TileSeal underlayment; loading boards or battens are required on roof pit 0000
l %greaterl"d:12". • • • • •
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed appro*,Ti of this pmdj1cj with • • : • • •
specific prepared roofing products. • • • • • • 900000
:00:0:
8. Tiles shall be stored on battens on roof pitches greater than 6:12". . . . ....•
. ..
9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of A cccVtance.listmg : ....
BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acctptance. 1f j3QF_*4L 9 •
TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ jM the
Miami -Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed
in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment
shall be applied over the underlayment, and sealed using an SBS modified mastic.
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below
END OF THIS ACCEPTANCE
NOA No.: 18-0502.03
Expiration Date: 08/02/23
Approval Date: 08/02/18
Page 4 of 4