Loading...
REV-19-3020r 126� ENTERED Miami Shores Village Department DEC 27 19 Building De p Will 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 (^ FBC 201:t ` r, BUILDING Master Permit No. k r 0 0 " l /936 PERMIT APPLICATION Sub Permit No. 61 -12- t QI- 3620 BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 1 O 634 N ' / (e+ City: Miami Shores County: Miami Dade Zip: 33 / 3 8 Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: BFE: NO FFE: OWNER: Name (Fee Simple Titleholder): )2r1 %A ar . s Phone#: 3og 3 og -Y77y Address: 10 (0 3 �( Pug t (C d- City: to (& MI S ko re State: C( Zip: 33 t'36 Tenant/Lessee Name: �1/� Phone#: Email:—�enna. Gass! r_ Tf \ otsocV, le'Vis. C�6^ A^� n I CONTRACTOR: Company Name: `'0r is,, t Phone#: oS% S 77 - l 0 8 q Address: (OGG % City: a!4yo 1 S lt,o ieS State: "F( Zip: 33 I5-1a Qualifier Name: t,4oLv(eoty kPM4-Z44,w. Phone#: 3or 91j" 7 — State Certification or Registration #: CC7 _) SZ6 IW 5 2 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: QQ City: State: Value of Work for this Permit: $ iy�0• �• Square/Linear Foo a of Work: Type of Work: El Addition El Alteration El New Repair/Replace Specify color of color thru tile: Submittal Fee Scanning Fee $ Permit Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ Zip: ❑ Demolition CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip -Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding .$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. in the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. SignaturSignature OWNER or AG T CONT4 CTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknow edged before me this 27 41% day of 6#-. 20 1 * by 2-7 1% day of Pe.cer•%se 20 11 by . tans, PASS 0 who is personally known to ��A7p4 ho is personally known to me or who has pr as me or who has produced as �c State of Florida �wtI, identification and k �fIY N. identification a 1k,6% ronC'State OfFwida aria Perez Ana Maria Perez NOTARY PUBLIC: �w y ommission GG 191084 NOTARY PUBLI a M ission GG 1910e4 E fires 02/28/2022 aft Aires 0 28I2022 i Sign: Sign: Print: ALlm Print: Seal: Seal: APPROVED BY lv%ans Examiner Zoning Structural Review Clerk VV (Revised02/24/2014) STRUCTURAL CALCULATIONS PROJECT ADDRESS: 10634 NE 11 CT MIAMI SHORES, FL 33138 CONSULTING ENGINEER: EDGAR MUNOZ, P.E. _ _ A41bI!cc FLORIDA LIC NO.50051 4815 NW 79 AVE SUITE #4 DORAL, FL 33166 .. ... . . . . . .. 0.0 . . . 000 .... ....... . . ..... . ... . ...... . .... .... . . .... . INDEX 1) DESIGN OF STEEL BEAM 2) DESIGN OF STEEL COLUMN 3) DESIGN OF STEEL BASE PLATE 4) DESIGN OF ISOLATED FOOTING .. ... . . . . . .. . ......... . .. ... .. . .... ..... .... ...... .. .. . .. .. .. .... ....... . . ..... . ... . ...... . .... .... . . .... . PAGE NO. 1TO2 3TO4 5TO6 7TO8 DESIGN OF STEEL BEAM Project: 10634 NE 11 Ct, MIAMI SHORES, FL 33138 Engineer: EDGAR MUNOZ, P.E. FL LIC No. 50051 1490 SHERIDAN ST SUITE #3A HOLLYWOOD, FL 33020 From AISC table 2-4, the material properties are ASTM A500 Grade B Fy := 46 ksi Fu := 58 ksi E := 29000 ksi 1:=22 ft W:=15 ft D:=10 psf L:=20 psf Q := 30 psf w:=Q•W=450 ftf Nlallowable•-- (w•12�=(27.225.103) lbf•ft '8 V..— ( — _ (4.95.103) lbf 1 ,Aallowable `= 180 =1.467 in 4 Imin'= (5 • w • l = 55.764 in 384 • E • ,Aallowable As per AISC table 1-11, Page 1-93 Try HSS 8 X 8 X 5/16 IX := 85.6 • in4 if (Ix >I„tin, "OK", "change section") = "OK" .. ... . . . . . .. Flange Compactness (Refer AISC table ].- 0!age:1�'93)'.. .. ... .: . .:.. Af:=24.5= t .. ... . ... ... ... Goo .. . . . . . .. .... ....... . . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . Created with PTC Mathcad Express. See www.mathcad.com for more information Width -to -Thickness Ratio Refer AISC table B4.1b Page 16.1-17 6P ,p:=1.12- 28.121 if (A f < AP , "compact", "non —compact") _ "compact" Web Compactness (Refer AISC table 1-11, Page 1-93) A,,, := 24.5 = h Width -to -Thickness Ratio, Refer AISC table B4.1b, Page 16.1-17 XI :=1.40.1 1-Y = 35.152 if (x"' < X,., "compact", "slender") _ "compact" As per AISC table 3-12, Page 3-144, available flexural strength Mavailable'= 35.6 . kip - f t if (Mavailble > allowable> M "OK", "change section") _ "OK" a Use HSS 8 X 8 X 5/16 .. ... . . . . . .. . . .. . . . . . . . .. ... .. . .... .. ... . ... ... .. . . . .. . . . . . .. .... ....... . . ..... . .. . . .. .. see . .. .. Created with PTC Mathcad Express See www mathcad.com for more information. lvI Project: 10634 NE 11 Ct, MIAMI SHORES, FL 33138 Engineer: EDGAR MUNOZ, P.E. FL LIC No. 50051 1490 SHERIDAN ST SUITE #3A HOLLYWOOD, FL 33020 DESIGN OF HSS COLUMN From AISC table 2-4, the material properties are ASTM A500 Grade B Fy := 46 ksi F," := 58 ksi E := 29000 ksi Q := 30 psf Al,,.d:=22 ft•15 ft=330 ft2 Lbeam:= 569 lbf Pallowable := Q' Aload + Lbe.=10.469 kip As per table C-A-7.1, Page 16.1-511, for pinned -pinned connection K:=1.0 LX:=9 ft LY:=9 ft (K•LX)=9 ft K•Ly) =9 ft As per table 4-4, Page 4-58, Try HSS 7 X 7 X 1/4 Pa:=223 kip = P. (Available axial strength) - 01 if (Pa >Pallowable> > "OK" "change section") = "OK" As per table 1-11, Page 1-92, HSS 8 X 8 X 5/16 geometric properties: Ay:=31.84 in rx:=3.13 in ry:= 3.13 in td,,:= 0.291 in Flange Compactness (Refer AISC table 4-litl Rage ]r93) : . • • ....... a 24.5 =— .. ... . . .. ... . ... ... ... .. .. . .. .. .. ... . . . . ... . . . . . . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . Created with PTC Mathcad Express. See www.mathcad.com for more information. 0 Width -to -Thickness Ratio, Refer AISC table B4.1b, Page 16.1-17 Ap:=1.12•r=28.121 if (Af<AP, "compact", "non —compact") ="compact" Web Compactness (Refer AISC table 1-11, Page 1-93) A,,, := 24.5 = h Width -to -Thickness Ratio, Refer AISC table B4.1b, Page 16.1-17 A,.:=1.40 •C = 35.152 if (AW:5A , "compact", "slender") _ "compact" (K• L.) - - 34.505 rX V4.71 =118.261 z Fe :_ • E 2 = 240.402 ksi K•LX Ty As per AISC Chapter E, Page 16.1-33, equation E3-2 Fy Fe ,.:= (0.6581 Fe - Fy = 42.46 ksi As per AISC Chapter E, Page 16.1-33, equation E3-1 Pn'=FCr-Ay=(1.352.103) kip ,f2c:=1.67 P. = 809.53 kip (Available comp ;e6sive st;er4gthj ; ; • • .fly .... . ......... . .. ... .. . .... Pn if >Palla,,,able, "OK", "NG" = "OK" f2� .. ... .... ...... Use HSS8X8X5 16 000 .. . . . . . .. .... ....... . . ..... . .. . . ...... . .... .... . . .... . Created with PTC Mathcad Express. See www.mathcad.com for more information. lJ Project: 10634 NE 11 Ct, MIAMI SHORES, FL 33138 Engineer: EDGAR MUNOZ, P.E. FL LIC No. 50051 1490 SHERIDAN ST SUITE #3A HOLLYWOOD, FL 33020 DESIGN OF BASE PLATE f'C:= 3 ksi Compressive strength of concrete Pa:=10.469 kip Required Strength Fy:=46 ksi F.:= 58 k8i Column details c1:= 8 in c2 := 8 in Available Strength for the Limit State of Concrete Crushing On less than the full area of a concrete support B :=12 in (Length of base plate) N:=12 in (Width of base plate) A1:=B•N=144 in (Area of column) B1:= 36 in (Length of footing) N,:=36 in (Width of footing) A2:=B1 •N1= (1.296.103) in (Area of footing) Pp:=0.85 • f' -Al • 1F(A)=122.4 kip if (Pp < 1.7 - f c • A1, "OK", "NG") = "OK" From AISC Equation 38-2 will control when A2 exceeds 4.0 2.31 Pp = 52.987 kip 97, if P� > Pa � "OK"' "NG" = C'OK" . ......... . For square HSS, the distance m or n is . ... .. . .... (N— (0.95 • cl)) m:— =2.2 in .. ... ... ... ... .. . . .. . . . . . .. m = n = 1 ... .... ....... . ... . . .. . . ...... . .... Created with PTC Mathcad Express See www.mathcad.com for more information. NO P f pa := Aa = 0.073 ksi i 2 Z t 2 = p 4 S?b :=1.67 M.=Mp=FyZ 2'f a•m2 tp (-q) :_ = 0.16 in p 'n6 Use 12 in X 12 in X 1/2 in thick plate Assume ASTM F1554 (4) 5/8 in dia anchor rod da := 0.625 in A,.:= 4 . dal = 0.307 in 2 Rn := 0.75 • F,a, • AT=13.346 kip Q := 2.0 R. = 6.673 kip 92 n:=4 Ra := n • � = 26.691 kip if (Ra,>Pa I "OK" 7 46NG17) = 46OK77 ..... .. . . . .. . ......... . .. ... .. . . . .. .. ... . ... ... ... • • • • • • . • • • • • • • • • • • • • • • • Created with PTC Mathcad Express.See www.mathcad.com for more information. Project: 10634 NE 11 Ct, MIAMI SHORES, FL 33138 Engineer: EDGAR MUNOZ, P.E. FL LIC No. 50051 1490 SHERIDAN ST SUITE #3A HOLLYWOOD, FL 33020 DESIGN OF ISOLATED FOOTING Load for support column: Aload:=330 ft2 Q := 30 psf - �Q -Al d) - — Lgravity:— 2 4.95 kip P,.in := Lgravity = 4.95 kip Pa:=1•6-Puri,,=7.92 kip Soil information: q8:= 2 ksf (Allowable bearing capacity of soil) t:=1 ft (Soil cover above footing) w8:=110 pcf (Unit weight of soil) we:=150 pcf (Unit weight of concrete) Material used: f'C:=3 ksi (Compressive strength of concrete) fy:=60 ksi (Yield strength of rebars) Column size details: ci := 8 in c2 := 8 in To determine footing size: D:=12 in (Assume footing depth) Q.,,t := qs — WC • D) — (w, • t) = (1.74.103) psf (Net soil bearing capacity) .. ... . . . . . .. A1eQ:= Pa =4.552 ft2 . . ... . QMt .. ... . ... ... ... .. .. . .. .. .. . ... ... . . . . ... . . . . . .. . . . . . . .. .. .. . .. .. Created with PTC Mathcad Express See www.mathcad.com for more information. Assume square footing Breq:= Areq = 2.133 ft B:=3 ft Consider 3 ft X 3 ft square footing To determine footing depth: Qu:= PaB2 =880 psf a. Check punching shear Assume #5 bars c := 3 in (cover) drebar:=0.625 in (dia of #5 rebar) d := D — c — drebar = 8.375 in (effective depth of footing) 2vu._Q.•(B2— (cl + d) • 1000 = 0.159 ksi 2•d•(cl+d)•144 Ove := 0.75.4 • V 3 = 5.196 ksi > 0.159 ksi (OK) b. Check direct shear Distance from the critical section of direct shear to the edge of the footing l:= B - 2-d=0.469 ft vu = (Qu, a = (3.42.10-4) ksi We := 0.75.2 • V3 = 2.598 ksi > 0.00034 ksi (OK) To determine reinforcement: Distance from face of column to the edge of the footing is Pmin:= 0.0018 Amin:=Pmin'B-d=0.543 in Use 4 #5 bars in both directions 4-7r-(d )2 •.. ..: . . .'. . : ... As:= rebar =1.227 in 2 > 0.5;L3 in.f- 14;.- i i.i 4 ...... . .. ... .. . . . .. Use 3 ft X 3 ft X 12 in square footing .. ... . ... ... ... .. . . . . . . . . . . . . .. . . . . . .. . ... . .... ....... . . ..... . ... . ...... . .... Created with PTC Mathcad Express. See www.mathcad.com for more information. E@