Loading...
RF-19-2731Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address D_T_ � a 1 KME Issue Date:11/20/2019 Parcel Number 169 NW 104TH ST, Miami Shores, FL 33150 1121360131370 Contacts Permit NO.: RF-11-19-2731 Permit Type: Roof Work Classification: Tile Permit Status: Approved Expiration: 05/18/2020 John Garcia JTRS Owner JOHN BUSTA ROOFING INC Contractor 169 104 JOHN ROBERT BUSTA 300 NE 91 ST, MIAMI SHORES, FL 33138 Business: 3052199699 Inspection Requests: Description: RE -ROOF SLOPED ROOF . TILE OFF CONCRETE Valuation: $ 22,000.00 Inspec i n Re COLOR THRU BACK ON 49 Total Sq Feet: 2,400.00 11 Fees Amount Application Fee - Other $50.00 CCF $13.20 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $4.40 Roofing Fee $250.00 Scanning Fee $9.00 Technology Fee $7.50 Total: $341.60 Payments Date Paid Amt Paid Total Fees $341.60 Check # 2244 11/20/2019 $291.60 Check # 2242 11/15/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I aythol_ze the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date November 20, 2019 Page 2 of 2 Miami Shores Village EN'rMHED • Building Department NOV152019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY - Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201 BUILDING Master Permit No. 19 - 2231 PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC 0 ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING [:]MECHANICAL ❑PUBLIC WORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS 169 NW 104 Street JOB ADDRESS: City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): John Garcia Phone#: 917-573-0947 Address: 169 NW 104 Street City: Miami Shores StaFlorida 33150 te: Zip: Tenant/Lessee Name: N/A Phone#: e Email: johngarcia@msn.com CONTRACTOR: Company Name: John Busta Rfg. Inc. Phone#: 305-219-9699 Address: 300 N.E. 91 Street City: Miami Shores State: Florida Zip: 33138-3130 � Qualifier Name: John Robert Busta Phone#: 305-219-9699 CCC State Certification or Registration #: -058048 Certificate of Competency #: N/A DESIGNER: Architect/Engineer: N/A Phone#: N/A Address: N/A 8l 14 City: N/A State: N/A Zip: N/A Value of Work for this Permit: $ 22,000.00 Square/Linear Footage of Work: 2400 s.f. Type of Work: ❑ Addition ❑ Alteration ❑ New ■❑ Repair/Replace Description of Work: Reroof sloped roof. Tile off concrete color thru back on ❑ Demolition Specify color of color thr0*111e.e '-"N/A Submittal Fee $ i'i �� t�Permit Fee S4 CCF $ CO/CC $ Scanning Fee $ 4-m - ` '.Radon„F�e.$ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Structural Reviews $ Double Fee $ Bond $ 566, TOTAL FEE NOW DUE $ (Revised02/24/2014) � L k G s v. Bonding Company's Name (if applicable) N/A N/A Bonding Company's Address city N/A State N/A Zip N/A Mortgage Lender's Name (if applicable) N/A N/A Mortgage Lender's Address N/A City N/A State N/A Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first insp n which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection wjirnot be proved and a reinspection fee will be charged. OWNER or AGENT The foregoing instrument was acknowledged before me this 12th. day of November 20 2019 b John Garcia y who is personally known to me or who has produced b� C7F7 W. 4'W ;72' Z1'0;Z0 as identification and who did take an oath. NOTARY PUBLIC: Print: Seal: My C�OpM�M�ISSION t GG 25M o�= EXPIRES. September 5, 2022 'f eF �`;°�r Bolded ThN Nawy Ptkk UwWipoen s**s*sssss****s******::ssssssss APPROVED BY `k 0 Signature (� CONTRACTOR The foregoing instrument was acknowledged before me this 12th. day of November o 19 by John R. Busta who tersonally know o me or who has produced as identification and who did take an oath. NOTARY PUBLIC: r i✓ YDA GkMERREZ :�•• �;; SORA MY COMMISSION N GG 25W99 �'/ ���;e� I M1!!'• Banded Tft N.Wy Pubk Und-V~ftM I / Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk F JIMMY PATRONIS CHIEF FINANICAL OFFICER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW * * CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 11 /19/2019 PERSON: JOHN R BUSTA FEIN: 651013141 BUSINESS NAME AND ADDRESS: JOHN BUSTA ROOFING INC. 300 NE 91 STREET MIAMI, FL 33138 SCOPE OF BUSINESS OR TRADE: Roofing - All Kinds and Drivers EXPIRATION DATE: 11/18/2021 EMAIL: JRBUSTA300@AOL.COM IMPORTANT: Pursuant to Chapter 440.05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be exempt... apply only within the scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 08-13 E01061315 QUESTIONS? (850) 413-1609 Local Business Tax Receipt Miami —Dade County, State of Florida —THIS IS NOT A BILL — DO NOT PAY 4378154 RECEIPT NO. RENEWAL BUSINESS NAME/LOCATION 4569308 JOHN BUSTA ROOFING INC 300 NE 91 ST ST MIAMI SHORES, FL 33138 EXPIRES SEPTEMBER 30, 2020 Must be displayed at place of business Pursuant to County Code Chapter BA — Art. 9 & 10 OWNER SEC. TYPE OF BUSINESS PAYMENT RECEIVED JOHN BUSTA ROOFING INC 196 SPECIALTY BUILDING BY TAX COLLECTOR JOHN R BUSTA, QUALIFIER CONTRACTOR 51.75 11 /11 /2019 Worker(s) 3 CCC058048 ECHECK-20-033592 This Local Business Tax Receipt only confirms payment of the Local Business Tex. The Receipt is not a license, permit, or a certification of the holders qualifications, to do business. Holder must comply with any governmental or nongovernmental regulatory laws and requirements which apply to the business. The RECEIPT NO. above must be displayed on all commercial vehicles — Miami —Dade Code Sec Ba-276. ru®QED For more information, visit www.miamidode.goy/taxcollector Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner - Workers' Compensation Insurance Exemption Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if: 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use day labor, part-time employees or subcontractors for your project. The contractor has provided an affidavit stating that he or she will be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of workers' compensation qsuTnce coverage from the contractor's company for day labor, part-time employees or subcontractors. BY SIGNING BELYYU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. 1 Signature: State of Florida County of Miami -Dade The foregoing was acknowledge before me this day of �pj, 20J_�__. By 6912/2 (57Q M Qo _ who 's personally known tb me or has produced n as identification. Notary: SEAL: SORAYDA GUTIERREZ R MY comet ioN # GG 25M BMW Thm Notoy PLek LIMW ikrs John Busta Roofing, Inc. 300 NE 91 Street Miami Shores, FL 33138 phone: 305-219-9699 email: jrbusta300&aol.corn November 14, 2019 State of Florida County of Miami Dade Before me this day appeared John Robert Busta who being duly sworn, deposes and says that he will be the only person working on the project located at 169 NW 104 Street. Sworn to (or affirmed) and subscribed before me this November 14'h. 2019, by Personally known X Print type or stamp Name of Notary := SORAYDACUTIERREZ MY COMMISSION S Gf3 25 01 =a I�RE•S::�Sye�pWmybper5,,220�222� p�EX ® /I.Y�PubkUnWwdbn Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. 1I Q -3 To: Miami Shores Village Building Department Datea•�%9 74 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: O/,//,/ GA,e 41A Property Address: lr0 9 "Z65V J77 Roofing Permit Number: Dear Official: , �Li/ gAkd-14 certify that I am not required to retrofit the roof to wall connections of my building because: XThe just valuation for the structure for purpose of ad valorem taxation is less than $300,000,00. Please attach proof of ad valorem taxaWfi,., ❑ The buj(dina was of 1994 State of Florida County of Dade in compliance with the provisions of the Florida Building Code (FBC) or with the provisions Florida Building Code (1994 SFBC) Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of kA� er Notary Public, Sate of Florida at Large �p i� .. •• SORAYDAGUTIERREZ .• ._ MY COMMISSION # GG 255699 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.0 nd the buH •' °• IRE September 5, 2022 g EXPIRES. September SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mir Revised on 5/21/2009 Property,Search Application - Miami -Dade County 8/21/19, 9:47 AM Address Owner Name Subdivision Name Folio SEARCH: 169 nw 104 st PROPERTY INFORMATION Sub -Division: MIAMI SHORES SEC 5 Property Address 169 NW 104 ST Owner JOHN GARCIA JTRS CARLOS J AVILA JTRS Mailing Address 169 NW 104 ST MIAMI SHORES, FL 33150 PA Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY _ 1 UNIT Beds / Baths / Hall 2/2/0 Floors 1 Living Units 1 Actual Area 1,752 Sq. Ft Living Area 1,728 Sq. Ft Adjusted Area 1, 623 Sq. Ft Lot Size 12,200 Sq. Ft Year Built 1951 Featured Online Tools Comparable Sales Report Discrepancies Value Adjustment Board Suite 4 Glossary PAAdditional Online Tools Property Record Cards Property Search Help Report Homestead Fraud Special Taxing Districts and Other Tax Comparison Tax Estimator Non -Ad valorem Assessments ASSESSMENT INFORMATION 9 Year Land Value Building Value Extra Feature Value Market Value Assessed Value 2019 2018 2017 $275,296 $262,514 $262,514 $154,380 $156,262 $111,221 $43,542 $43,996 $0 $473,218 $462,772 $373,735 $232,207 $227,878 $177,055 BENEFITS INFORMATION 9 Property Taxes TRIM Notice Benefit Type 2019 2018 Save Our Homes Cap Assessment Reduction $241,011 $234,894 $19( Homestead Exemption $25,000 $25,000 $2F Second Homestead Exemption $25,000 $25,000 $2! Note. Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). https://www8.miamidade.gov/Apps/PA/propertysearch/#/ Page 1 of 3 4 t Ll ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Y.0 PT �. ` I Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. i 1 Section A (General Information) i 1 Master Permit No. Process No. • 1 • • 0. Contractor's Nam • • : • • j • Job Address ... ; , • ROOF CATEGORY •••••• �••••• •..!•• ❑ Low Slope ❑ Mechanically Fastened Tile MortaV/ ;geesleve Set Tiles: • • • • • ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood•Shingies/Shakes • • • • • • • • ❑ Prescriptive BUR-RAS 150 • • 0001.0 ROOF TYPE : • • • ' • • • •. ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recoyarye i • ROOF SYSTEM INFORMATION 1 Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF) Total (SF) Zq 1 1 1 Section B (Roof Plan) i Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 Q 0 .. ME 0 M ON ME MENNEN! ON ►MEN! 0 no No� W NNNE s o\■moniom\s\I/ mmm1 M INN �I �%������������� M Milo 1IM11M ME M MMMMM�r ON MAP 1 M 111 ME �r���ME IN �� ����aim E MIN ME M FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Copyright to, or licensed by, [CC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun g, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. I 1 1 1 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form I a Section D (Steep Sloped Roof System) 1 Roof System Manufacturer: &ML �-7 � Notice of Acceptance Number:. V/ -- 04tw - 0' 1 n Wind Pressures, If A • • • Minimum Design pp icable (From RAS 127 or Calculations): 1 "":' _ • R • • • Pi P1: — P1: (�t7i••••• r r•r••• • '•r••i• ••r• • • Deck Type: //'''' •••• • • r 1••••r Type Underlayment: 3 ,t „ I t toooqf 1pe: � �/r�i /J � � � :-•�.-�-•- � 1 • • 1 '. 1...... Insulation: 1..... • t Fire Barrier: I Ridge V Y abon? 1 Fastener Type & Spacing: Adhesive Type: 1 Type Cap Sheet: ` 1 1 Mean Roof Height: Roof Covering:'�C 1 Type & Size Drip` 1 Edge: 1 1 1 FLORIDA BUILDING CODE •— BUILDING, 5th EDITION (2014) 15.39 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on lun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 i 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 I i I ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. 0 Section E (Tile Calculations) • • • For Moment based the systems, choose either Method 1 or 2. Compare the values for M, with the valulsf�qq�rr��•l1 j�vvlIf. If the M, values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is accepfable. Method 1 "Moment Based Tile �Ca�l�culations Per RAS 127" "' • • (P1: x X M =/ rl�-) - Mg: = Mr, / 7 D Product Approval M, 3� �' • •• • •' (P2' xxt _.) - Mg:h= Ma Product Approval M, J ?S, %' '' • • • (P3;&x7u -� i) - Mg:6. = M;M Product Approval M, •. • • Method 2 "Simplified Tile Calculations Per Table Below" ; 0.0 Required Moment of Resistance (M,) From Table Below Product Approval M, • • • M, required Moment Resistance' Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 "Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1:_ x L _ _ _ x w: _ _) - W: _ x cos 6 _ = Fr, _ Product Approval F' (P2:_ x L _ = _ x w: = _) - W: _ x cos 0 _ = F2 _ Product Approval F (P3:_ x L _ = _ x w: = _) - W: _x cos 9 - = F� _ Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 9 Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity M9 Product Approval Attachment Resistance M, Product Approval Required Moment Resistance M9 Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) t s I 1 1 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. MIAMa DE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 %1.JOV 15-2599 NOTICE OF ACCEPTANCE (NOA) ' W.ww..niarnld•aae.g°vie�°"o11,�• • ...... . ...... Boral Roofing, LLC • 7575 Irvine Center Drive, Suite 100 ; • • • •; Irvine, CA 92618 • • • • ..... SCOPE: • • • • • • ...... This NOA is being issued under the applicable rules and regulations governing the use of adtis' 41ion materials. The • documentation submitted has been reviewed and accepted by Miami -Dade County RER - Pioduct'Contr0l 444on to'W • • • used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdk J1-pn tAHJ)* :....: .. . This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Corit;X1. ection (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.18-0509.15 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino in NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufa;turpd.BoraMRoofing LL•C" in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure r&uirhients, as • determined by applicable Building Code, do not exceed the design pressure values bbEa`ined by calculations In• 0 compliance with RAS 127 using the values listed in the installation section herein. floeo Optotachmelit calculatiobt .... shall be done as a moment based system. 000000 : ""' ..... 2. PRODUCT DESCRIPTION Manufactured by ADDlicant Dimensions Barcelona 900 Length = 17" Width = 13" ''Y? thick ...... . ... ..... .. .. .. . ...... Test #roauit • Specifications Dacriedon :....: TAS 112 High profile, interlocking, one-pi8c4,.'S'shaped, Type — la high-pressure extruded concrete roof tile equipped with three nail holes. For direct deck or battened nail -on, mechanically fastened, mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete Width: varies roof pieces for use at hips, rakes, ridges and varying thickness valley terminations manufactured for each file profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polysee AH-160 TILE BOND" Roof Tile Adhesive DAP Foam Touch N Seal StormBone 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof file adhesive. Two component polyurethane foam adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL Manufacturer (With Current NOAI ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam Inc. NOA No.: 19-0408.02 MMMMADECOUNTY Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test Aeencv Test Identifier Test Name/Revort Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 104A) :""' • • • • • • Redland Technologies 7161-03 Wind Tunnel T89tinp : •Dee? 1991 • Appendix II TAS 108(N%1*;Q►I . . Redland Technologies P0402 Withdrawal RgiostanV ; .$%L 1993' ' Testing of screw vs". t1dooth ""' shank nails :": •• :•: ••••• Redland Technologies Letter Dated Aug. 1, Wind Tunnel Tasting Aag. 1994 •. 1994 TAS 108 (Nail -On) • ;...;. """ Redland Technologies P0631-01 Wind Tunnel July 1994 :"' •: TAS 108 (Mortar Set) ' Professional Service Industries, Inc. IC-1320-94 Physical Properties Feb. 1995 TAS 112 The Center for Applied Engineering, Inc. 25-7688-3 TAS 101 (Adhesive Set) June 1996 25-7688-10 TAS 101 (Mortar Set) July 1996 The Center for Applied Engineering, Inc. 25-7688-5 Static Uplift Testing June 1996 TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) The Center for Applied Engineering, Inc. 25-7688-4 Static Uplift Testing June 1996 TAS 102 (4" Headlap, Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier 09/01/16 Walker Engineering, Inc. Evaluation Restoring Moments Due to 09/01/16 Calculations Gravity American Test Lab of South Florida RT0617.03-16 TAS 112 06/29/16 PRI Construction Materials Technologies COPO-002-02-10 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-02 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) PRI Construction Materials Technologies COPO-002-02-01 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 3 of 7 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may require, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Department of RpMatory and Economic Development — Product Control Section for review. : .' . a 000 • ;' 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Stai;dwds•listed section 4:1 herein. • 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to tho roof slope unless stated' • • •; otherwise by the underlayment material manufacturers published literature. ... • ..... 3.6 This acceptance is for wood deck applications. Minimum deck requirements shatl•1 a i4 comp jiatWwith • • : • • applicable building code. " • • • • . . . . ...... . . ...... 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) 1 Length-1 (ft.) Width-w (ft.) 1 Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - A (W) Tile Profile A (W) Batten Application A (ft3) Direct Deck Application 11 Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity - M9 (ft.-lbf) 14, Tile Profile 219:12" 3":12" 411:12" 5":12" 614:12" 7":12" or greater Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.19 7.07 1 6.19 7.00 6.19 1 6.90 1 6.06 6.76 1 5.92 6.60 1 5.76 6.42 NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" (min. 19132" • • plywood) p119dod) • • •19.4 Barcelona 900 2-10d Ring Shank Nails 28.6 OV.7' ' "' 1-10d Smooth or Screw Shank Nail 5.1 •2.8 ; • • •••••• 2-10d Smooth or Screw Shank 6.9 .l 2 % ..7.3 • •: Nails .. .. • .. . ... 1 #8 Screw 20.7 . • • . 18.1 2 #8 Screw 43.2 '43.2 ' :... 5U9.8 1-10d Smooth or Screw Shank 23.1 3.4 : 7 . .19.0 ; • • l (Field Clip) • 1-10d Smooth or Screw Shank 29.3 29.3 24.0 Nail Eave Clip) 2-10d Smooth or Screw Shank 27.6 27.6 38.6 Nails Field Clip) 2-10d Smooth or Screw Shank 38.1 38.1 41.8 Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" (min. 19132" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4" tie headlap and fasteners are located a min. of 2'/z" from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mr (ft-lbf) for Two Paddy Adhesive' Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Tile BondTM"One Component Roof Tile Adhesive 29.32 ICP Adhesives Polyset@ AH-160 two -component foam 29.33 DAP Foam Touch N Seal StormBond®2 Roof Tile Adhesive 664 1 See manufactures component approval for installation requirements. 2 TILE BONDTm Roof Tile Adhesive; Average weight per paddy 10.7 grams. 3 ICP Adhesives and Sealants, Inc.'s ICP Adhesives'Polyset AH-160; Average weight per paddy 8 grams. 4 DAP Foam Touch N Seal Storm Bond® Roof Tile Adhesive Two -Component; Average weight per paddy 8 grams. NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum j%ttaghment . . Resi$tddee ... Barcelona 900 ICP Adhesives Polyset® AH-160 two -component foam ' 6Ea5 ::. 4 ICP Adhesives Polyset® AH-160 two -component foam 6 0.;.. 38.760 . DAP Foam Touch N Seal StormBond®2 * • • • • 6p.; �; • DAP Foam Touch N Seal StormBond®2 ...82 8 • •. .., 5 Large paddy placement of 63 grams • • • • • • see 6 Medium paddy placement of 24 grams 000000 • 7 Medium paddy placement of 30 grams 8 Large paddy placement of 60 grams • • ' :.. Table 8: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set9 24.5 9 Seespecific mortar manufacturers Notice of Acceptance 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". ra-l"D LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 6of7 PROFILE DRAWING NAIL HOLES 17" UNDERLOCK BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 19-0408.02 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 7 of 7 MIAMN ADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidedeg;w economy Polyglass USA Inc. • • • • 0 • • II11 W. Newport Center Drive Deerfield Beach, FL 33442 ...... . ...... SCOPE: • • • • • • • • • • . ...... . ... ...... This NOA is being issued under the applicable rules and regulations governing the use of coadmeiion materials. The • • •: • documentation submitted has been reviewed and accepted by Miami -Dade County RER - Prgdap, Control Sdttion to be '. used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).:...:. "' •' This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Corltror Section • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino., NOA No.: 17-0614.22 MLAMMADE COUNW Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Pro":. + • Product Dimensions Specification • Descri iat • Polystick IR-Xe 65' x 3'33/8" ASTM D 1970 +.+++ A fine granular/sand top surfacg'.Sgjl adher Yjg.aP ..:..' Manufacturing Or 65' x 3' polymer modified, fiberglass rgjtlfyted, bitua inbus • • +.:. Location #1 & #2 60 mils thick sheet material for use as an underlayment in sloped roof - assemblies. Designed as an ice &rain shie$d • • """ Polystick Dual Pro 61' x 3'33/8" TAS 103 and A rubberized asphalt self-adhjring,*41ass-fi�berApolyestei� 0 Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a Location #2 metal roofing and roof tile underlayment. Polystick Tile Pro 61' x 3'33/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal Location #2 roofing and roof tile underlayment. Polystick TU Max 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self -adhering, polyester reinforced Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile Location #1 & #2 underlayment. Polystick TU P 32' 10" x 3'33/8" TAS 103 and A rubberized asphalt waterproofing membrane, glass - Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface Location #2 designed for use as a tile roof underlayment. Polystick TU Plus 65' x 3'33/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester (Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location # 1 & #2 Polystick MTS 6518" x 3133/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefmic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick MTS Plus 6518" x 3133/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastoflex S6 G 32'10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. NOA No.: 17-0614.22 CMhADADfi COUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL .. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Renort • • • • • Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. LABELING: P 10870.09.08-R1 P 10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390.08.12-2 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC 10130.06.16-3 PLYG-10130.06.16-1 PUSA-035-02-01 PUSA-055-02-02 PUSA-089-02-01 JX20H7A RX 14E8A DX23D8B DX23D8A TAS 103 •••••• TAS 103/ASTM D4798 &.IG155. ASTM D1970 • •' •.' TAS 103 •••••• ASTM D 1623 • TAS 103/ASTM D4798 & G15e - TAS 110/ASTM D4798 & 1)1�70• ASTM D 1623 ASTM D6164 TAS 103, TAS 110 & ASTM D1623 ASTM D1623 TAS 103 & TAS 110 ASTM D 1970 & TAS 110 TAS 103 & TAS 110 ASTM D1970 & TAS 110 TAS 103 TAS 103 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 • Date � T '17/04/08 "11/09 O'7/0t/10 03702/11 :04Akl11 094Q1/11 ' 10410/ 11 08/07/ 12 07/02/13 05/12/14 10/03/14 10/07/14 10/17/14 06/27/ 16 06/27/16 09/29/06 12/10/07 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Mn. 19/32" plywood or wood plank :goo:* System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered " • • • • • • • •..:. •••J•• • Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. ...:.. ;....: Fastening: • Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a nnnnm 4" �eaQldp. (for... • mi •••• base sheet only) ... • • • • • Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick ... goo TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plu j,'solr adherefl. ....:. Surfacing: % See General Limitations Below. :....: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. ; .. ; • 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtaifl'M4%tnnum Remove the release film as the membrane is applied. All side laps shall be a minimum M 3* and end taps shall be a minimum of 6". Roll the membrane into place after removing the release strip. l ejic al straipin4gf the • • • roof with Polystick is acceptable. Membrane shall be back nailed in accordance with gppUQable building code:'; • • • ..... 4. When applying the membrane in the valley, start at the low point and work to the higtrpoint, roll A'sAe: .... • membrane from the center outward in both directions. •; . • 5. For ridge applications, center the membrane and roll from the center outward in both directions. • • .... • • • • • 6. Roll or broom the entire membrane surface so as to have full contact with the surface,- giving special Atentior, .... to lap areas. 0466. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Ez osure Limitations (Days) MTS IR-Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven FL 180 90 180 180 180 180 180 180 180 Hazelton PA N/A 90 N/A 180 N/A N/A N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 MAMMAD�ffjgzt, COUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 8. 9. Rule 61G20-3 of the Florida Administrative Code. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may by used in botLadllesive set and mechanically fastened roof tile applications. ' .. • ; • Polystick Dual Pro is limited to mechanically fastened roof t. 0 0 0 0 0 • he applications. • • • • •. • Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the lernitations outlined in . • Section 9. "" • • • """ ...... Polystick TU P may be used in mechanically fastened roof tile applications with the exception of fnortar set tile*... applications. .. .. • ' • • • • .. . ...... When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies,�the";ximum roof slope . • •:fee:,....:. shall be as follows: (See Table Below) � 0 Tile Polystick Elastoflex Polystick TU Plus, Polystick Pol stfClc S stun E3 "•; y y y y I. ) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus •( MTS;Itis with Dual Pro TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. m a 0 U) N m POLI'SnCKIU Rus NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Poo, ..... Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, PolgstickiViTS...... Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptaq . . :..... • If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Po1WM TU P, Polystick • • • • • • TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a requwA may bg made to tha.... : Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section -for' appro-MI'pibvided... that appropriate documentation is provided to detail compatibility of the products, widid pptill resi stance pand fitg:..' testing results. • • • • • .... POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTIM MMBAMA .. . . .. ...... PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLWXYIONS. • • LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 V metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading file on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of T/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 MIAMMADE COUNTY Expiration Date: 09/13/21 IM Approval Date: 07/06/17 Page 7 of 8 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick . membranes commences. An approved substrate technical bulletin can be furnished upon request. Itis ...,., recommended to refer to applicable building codes prior to installation to verify acceptable silbstratrsg •' 12. •; • The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranss can be furnished , • • • • • upon request by our Technical Services Department by calling 1 (800) 894-4563. 660000 ; • • • • 13. Questions in regards to the application of Polyglass products should be directed to our iw6jo rlical Services • •: • •, Department at 1 (800) 894-4563. • • • .. .. • • "' • , • 14. Polyglass recommends that applicators follow good roofing practices and applicable ITocsd>:res as•outlined by • the National Roofing Contractors Association (NRCA). 0 • • • • • • "goes 0 •• • • •, • •••••• PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIN[ITATIONS OF SPECIFIC APPLIM'MONS. • LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8 of 8 MIAMMIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 441" Street :' •"' ,.. Coral Springs, FL. 33065 0' ...... . ...... SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of �W0bctiorC M,1tefials. 11; documentation submitted has been reviewed and accepted by Miami -Dade County RER -Pwidi".Control Section tO.lw..' used in Miami Dade County and other areas where allowed by the Authority Having Jurisdietiox•CCAHJ). * • • * • • • • • • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County 1'rQduct Contrpl Secti A.:. (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to hild iHit product or material tested for quality assurance purposes. If this product or material fails to perform in-414accep ed manner, W * 0 manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof file adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. J!6*;eribed...... in this Notice of Acceptance. For the locations where the design pressure requirements, as detesnia*ed by.applicable • • building code, do not exceed the design pressure values obtained by calculations in complianwrith Rootaj ' • .... ; . Application Standard RAS 127. For use with approved flat, low, and high profile roof rile sy! tBM•using ICP Adhesives Polyset® AH-160. ." ; • •; • .... . ... .. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications ICP Adhesives N/A TAS 101 Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: ...... . .. .. .. . ...... Pro duot'D'efdrintion • • • ...... Two component po lare4iane 6vi-adhesi�e . . .. Dispensing Equipment Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ftz 3.1 Perm / Inch +0.07% Volume Change @ 400 F., 2 weeks +6.0% Volume Change @1580F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94-060 257818-IPA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[1] 7050.02,96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 '..' ASTM D 1623 •••.•• ASTM E 108 ASTM E 108 ; ASTM E 84 TAS 114 ASTM D 1623 TAS 101 TAS 123 TAS 101 TAS 101 TAS 101 RAk 04/08/94 12/16/96 10/25/95 jP/04f95 12/1205 • 0 0 0 • • 02/Od/94 00 0 0 11/16194 a IP1"95 03A*4 04/18/12 02/21/12 10/23/98 12/28/98 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof rile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof rile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RYAS V7. Thp'atl4sive • • • • • attachment data is noted in the roof tile assembly NOA. 9..9 ' &' ...... 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance W' U. 8ofing'Apelication" "" Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and i`liainlenance Booklet. :....: 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licenselby*dZ!� Adhesives and • • • • • Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicattlts 18;lie autltogtyhaving• o • • jurisdijurisdiction... .. •• • •.•...• 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is kqulydd before applicatio& .. ; . of any adhesive. The mix ratio between the "A" component and the "B" component shall be mainCi edlietweon 1.0-1.15 (A): 1.0 (B). • • 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or I P Adhesives ProPack' 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset' AH-160 has been dispensed. 9. ICP Adhesives Polyset' AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches J5-61 Profiles ... • • Flat, Low, High Profiles #1 17-23 sq. inches .' : 45-61 Flat Profile #2 10-12 sq. inches '." . 30 ••• Low Profile #2 12-14 sq. inches ... . 30 • ; • • High Profile #2 17-19 sq. inches ' 30 • • Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches a1 .. 2 grams.per�addy... head of tile 9-11 sq. inches at % % • • • • overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 7 gram per bead:" edge) 20-25 sq. inches each • • • • bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMFDiADE COU� NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 Igil &=% plank caei.srt ►addy Itian•athTrt i IrAars r•qukad) undrrwym•nt '� * loinrti'�� EawGain. -4 tor.. `M Fascia Err. O.sum Nall through pbstic cement iwhew reaulred) paddy 111" it TX*l llnd.rl•y 0" t -;r 2l �rsx � •, en.wtd• �►� fattens optional . 6•v tnn►s• ` Fascia KA lhroagh pl•selc twhan requAre�d! Fwddy ldrn.•thTllrl V"dw*y1W t a toyn.x .F 2 in.wlda battens opllonal ° Eara courm Fasda Weephofe if h► In. fare dosure .i Crip•dga Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening:ib pfgsest to the Overlock• • • • • • of the tile being set. " • • 2. Continue in same manner ensure approximately 17...: (109.7 cm2) — 23 (148.40q;.Ijsquare; nth;dhesi %q�... • contact with the undersWwwt the tile.. ... .0; 0 • • 00 • f • • • Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the file being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 ttall through phatict•mane P.ddylhnstthTik) twhaw nqulnO tledaltyWrA • lrti y .21n.'`� Batbe t optional • uvo coon• • • ` 101nFalcla �.� 2 1n Ear. clown Na+l through plastic cement (whew required) Paddy (Raneath Tile) ndmisyew•et 114"em optional 10 = M. [aw clesur• [are cmrso Faseta Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shqwn ceder the strengthening rib of the tile•closest to th$•fireilock o f . • • • • the tile being set. Insure appr@Zffl*ately l7•Q09.7 cmZ) . 00 — 23 (148.4 cmZ) square inch t4hesive oontact with the. • • . underside of the tile. • • • • • • • .... . . • 2. At the second course, apply a minimum 2" 0.8mm?': •• -. x7"(177.8mm)x1"(25.4��foamp�ih:••y underlayment positioned assbovw under tlje strengthening rib closest tathe overlock of die tile ....:. being set. ; • • • ; • • ; 3. Continue in same manner. Insure approldi6e*1y 10" (64.5 cmZ) - 12 (77.4 cmZ) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the file being set. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the file being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cmZ) square inch adhesive contact with the underside of the file. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nall thnmo pasik to O A.n "lad) /rddr IpowwATiIN '2 rn. Battens eptlaeul e, cep 'e56e woorpll1 loin. 2In. Ewe desae Orip edge High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment pos4ioneli as shojwxu;ider the pan portion of the tile clos&4 ld t4e ove;lockof the • • • 00 • tile being set. Insure approximately 17 (2W.7 tm2) ; • • ; • 23 (148.4 cm2) square inch adh6tive contacA with thQ underside of the tile. • • • • . .... . .... . 2. At the second course, appl' a.Mm ial mum.2" Z30.8m)• • • • x 7" (177.8 mm) x 1" (25.1' * J foam paddy onto the' underlayment positioned a$ shay undgr the pan • • • • portion of the tile closest to the overloctVf t tile • being set. • . .. 3. Continue in same manner. Insure approximately 17" (109.7 cm') - 19 (122.6 cm') square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Mnthragh plastic cement Paddy (between ties) Battersopdonai ' 1 Vaddy hinder tlle) r sin* mtopoftier t. 2X Ir 4 • to 2 in. Eave dCAR Flat/Low Profile Tile Haq through pludc eernertt Single paddy under tile (MM required) Pa (between ties) Battens paddy (under tle) optlonal pad 1 ' onfop tile`' iZ 41n. y =. hl paddyen 01n. ~` 21n. Eme Closure Eave Course Fasda Medium ProflleTile MIAMMADE COUNTY111111 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high prc�fgg jvg closest to the ovcrlock of the tile* boino set. Leave """ approximately 4" (101.6•�l yp froi•t4aave ' • edge free of foam to re.000000 g p yppj �e expanded adhesive • from blocking the weep Wes. Insurr, o : • • • • approximately 17-23 in2' •W& %-148.4 cl$�'of adhesive contact with tim-ir glside of tl� the • • o • •' ••• ••• • •• • w.•... • •••• • 2. Apply a 4" (101.6 mm) x 4" tf01.6 Aix► !1" (25.40*" mm) foam paddy onto thgjffi4rlay4cnt ust below• •. the second course line positioned foMgp.'ggdy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in' (51.6-58.1 cm') of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nall drvogh plastic S6Kje paddy under to* (when nequked) Pa&ylbetreeen tiles) Batten optbnat Paddy(rsderdle) � . f 1 w�on 4 z 41n. Sbfie 2 x 4 in. Pa top d Ne a<a. Weephok Eve aosm odpedge H4h Ptoff%Tile 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x'/4" (19 mm) paddy on top of the cave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of -the tile, closest to the underlock2Df tbe�first course of tile.• • • •.. Install second course of tM. Insure 4Wpjunately • 9 (58.1 cmZ) - 11 (71cm�e.Zlic se'uAre inch adhesive • • • • • • contact with the undersi fileat the overlay...: and 7 (45.2 cmZ) - 9 (58. J Fad square iitv-r adhesive contact with the. modgrside of tbg file at:.: ; • the head of the tile. Continua ui samtim5der. . . . . ...... . . . .. . . .. . . . .. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 6S to 70 sq. in. Steep pitch applications In contact with the pan tile. (when required) 2) Turn covers upside down. Pla;&dhesive In to 1 in. from outside edge of covThen install the tile. Ensure 20 t 25 sq. In. contact area. IUnderlayment Eave uosuri (motar shown) Fascia Remove top portion of the eaw course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile l . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringingtwo pan courses up toward the:ridge.•lnsure • • • • • • approximately 65 (4191tcmt) — N445L6 cm2) •. square inch adhesive coAVUwith the underside; of the pan tile. •••••• .... . ..... 3. Turn covers upside dowmeyosing the vuderside. L.' of the tile. Apply a rn"Ium 1" (T min) x 10:..:. (254 mm) bead of adl siV directly otr the inner - edge of each side of the cover tile. JgANL • • • • • • approximately 3/4" (W mdl� to 1" 125.4 mm) :....: from the outside edge oi•the tile, iltwaid,•frce of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOF CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor.'.%e,Q?jpers initial in the designated space indicates that the item has been explained. • • • • • • 2. Renailing wood decks: When replacing roofing, the existing wood roofdeck gave to • • • • may be renailed in accordance with the current provisions of Section R4403. (The reofdeok is ustly • • • concealed prior to removing the existing roof system). • • , ...... . ... ..... 4. V Exposed Ceiling: Exposed, open beam ceilings are where the uriersiddof the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; th&ei'o`re * • 0 9 0:0 0 • roofing nail penetration of the underside of the decking may not be acceptable. This ppvides jh%option of • • maintaining the appearance. .... 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is, not ove loaded from a buildup of water. Perimeter/edge wall or other roof extension may block this d' if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scup rs ' accordance with the requirements of Sections R4402, R4403 and R4413. wrmg`envsSi ture Date Contractor Signature � Date lb9Nu le Property Address Permit Number Revised on 7/9/2009 LD;07/01/2015;