Loading...
RF-19-1457Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Issue Date: 07/02/2019 Parcel Number 10221 NE 13TH AVE, Miami Shores, FL 33138 1132050230150 Contacts Permit NO.: RF-06-19-1457 Permit Type: Roof Work Classification: Repair Roof Permit Status: Approved Expiration: 12/30/2019 MARIA SUAREZ Owner 10221 NE 13 AVE, MIAMI SHORES, FL 33138 Home: 305-308-5040 T&S ROOFING SYSTEMS INC. Contractor LOUIS TOLEDO 1461 NW 23 ST, MIAMI, FL 33142 Business: 3052652654 Other:3057727954 Description: TILE ROOF REPAIR Valuation: $ 2,200.00 Inspection Requests: Total Sq Feet: 50.00 Fees Amount Application Fee - Other $50.00 CCF $1.80 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $0.60 Roofing Fee $50.00 Scanning Fee $12.00 Technology Fee $6.25 Total: $126.90 Building Department Copy Payments Date Paid Amt Paid Total Fees $126.90 Check # 36415 07/02/2019 $126.90 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate regulating construction and zoning. Futhermore, I authorize the above named i that all work will be done in compliance with all applicable laws jr to do the work stated. 1- _L0\ Authorized Signature: Owner / Applicant / Contractor / Agent Date July 02, 2019 Page 2 of 2 RECEIVED (IzSV BUILDING PERMIT APPLICATION Miami Shores Village iu 2 019 Building Department BY: 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 I� Master Permit No. —cj6 (gi - J L4 5� Sub Permit No. ❑BUILDING ❑ ELECTRIC 1� ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: N Z Citv: Miami Shores Folio/Parcel#:At Occupancy Type: _ 0z - 0 in Is the Building Historically Designated: Yes NO _ Load: Construction Type: Flood Zone: BFE: FIFE: OWNER: Name (Fee Simple Titleholder): Address: �,2I g I' Phone#: -30EZ_+C-7 City: %Ye� (, State: _ Zip: J 1 �b Tenant/Lessee Name: Phone#: Email:y(p oS- CONTRACTO : C mpany 'Na..m11e: G�i l� ` Phone#: �k J I Address: W City: Stater Zip: Qualifier N me: 001S Phone#: State Certification or Registration #: v Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: /� City: State: Zip: Value of Work for this Permit: $I -Zoo Square/Linear Footage of Work: -1)0 !�qjE± - Type of Work: ❑ Addition ZI Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (V (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this �-5 day of 20 , by who is personally known to me or who has produced identification and -who did take an oath. NOT Sign Notary public State of Florida David Alexander Carrasco • 3 ! r ....r..iaaien GG2241618 as Signatu CONTRACTOR The foregoing in 1(rument wa`s Aacknowledged before me this Of vv 20, by ( who is personally known to me or who has produced as identification and who did take an oath. NOT R %UBLI ,�w Notary Public State or Florida +� �� David Alexander Carrasco � MY Commission GG 241618 1 �� � Expires 0712512022 Print: 1 I M�� sG v Prin . 1 �01 7) CQ Seal: Seal: APPROVED BY ?4VZ1 y Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) , Page 1 of 2 Manuel J. Vaditta, Esq. Snnclttc va ditto LLP 11402 INW4111 Street, Set202 Durtr, Ft.33178 VR-1940. 6 Return iD; CM11a Armenteros, F-sq. Armentem, Low, P.A. 9054 Pines t11vd., Suite 336 Ptmbrake Pine$, R. 3.1924 Paw) Idmificeticm Nw I I.3-05-023-0150 CW 20190258316 BOOK 31418 PAGE 725 DATE:04M/2019 08:13:A1 AM DEED DOC 99,300.00 IIARVEY RUVIN, CLERIC OF COURT, MIA-OACE CTY e ism t one rw ILe _kV WARRANTY DEED (STATUTORY FOX.M - SCCTION W,02, F.S.) This indenture made the ..G day of April, 2019 between Marix Suarez afic/n Maria C. Suarez,, a sing to woman, whose post office address is 973 NE 96" Street, Miami Shores, FL 33138, Grantor, to DONALD E. C1HAK Trust dated December 27, 2007, as further amended and restated, whose post office address is 10221 NE 13`s` Avenue, Miami Shores, FL 33138, of the County of Miami Dade, Florida, Grantee. Witnesseth, that said Grantor, for and in consideration of the sutra of TEN DOLLARS (U.S. S10.00) and other good and valuable considerations to said Grantor in !land paid by said Grantee, the receipt whereof is hereby acknowledged, has granted, bargained, .and sold to the said Grantee,, and Grantee's !heirs and assigns forever, the fallowing described land, situate; lying and being in Miami -Dade, Florida, to -wit: Lot 1, Block 4, of MIAMI SHORES BAY PARK ESTATES, according to the plat thereof, as recorded in. Plat Book 55, Page(s) 83, of the Public Records of IN-fland-Dade County, Florida. Also known as 102.21 NE 1.31b Avenue, Miami Shores, FL 33138 Parcel Identification Number: 11-1205-023-0150 Together with all the tenements, hereditaaTments and appurtenances thereto belonging or in anywise appertaining. Subject to taxes for 2019 and subsequent years. not yet due and pay -able; covenants, restrictions, casemewts, reservations and limitations of record, if any. TO HAVE AND TO HOLD the same in fee simple forever. And Grantor hereby covenant with the Grantee that the Grantor are lawfully seized of said land in fate simple, that Grantor have good right and lawful authority to sell and convey said land and that the Grantor hereby fully warrant the title to said land and will defend the same against the lawful claims of all persons whomsoever. watmwy ocm Pate I tail https:Honlineservices.miami-dadeclerk.com/officialrecordslCFNDetailsHTML5.aspx?QS=... 5/24/2019 • Page 2 of 2 CFN: 20190256315 BOOK 31418 PAGE 725 In Witness Whereof, Grantor have hereunto set Grantor's hand and seal the day and year first above written. Signed, sealed and delivered in olrr pretence. 6 Marfa Suarez alk/a Maria C. STATE .FLORIDA COUNTY OF MIA -MI -DADS The foregoing instrument was acknowledged before me this vt�', ay of Apia, 2019, by Maria. Suarez aWa Maria C. Suarez, who is,persrs 11 �knqwr� to me„or who produced a as identifiicat' n Signat f N& public �'~`` `'w YAIUANA LEYVA r .State of € oridat-MKary Public Print. "t ypelStarn t, of Notary y caMmtasior, r cG 213028 ..�.'� My Corm S4f 2032piies Personally known: V OR Produced Identification: Type of Identification Produced: YasM"Oyrxkd 1"Ve 2 of 2 https://onlineservices.miami-dadeclerk.com/officialrecordslCFNDetailsHTML5.aspx?QS=... 5/24/2019 I 1 , I' . dF Summary Report Property Information Folio: 11-3205-023-0150 Property Address: 10221 NE 13 AVE Miami Shores, FL 33138-2637 Owner MARIA SUAREZ Mailing Address 10221 NE 13 AVE MIAMI SHORES, FL 33138-2637 PA Primary Zone 1400 SGL FAMILY - 3001-3250 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/1 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 3,164 Sq.Ft Lot Size 11,415 Sq.Ft Year Built Multiple (See Building Info.) Assessment Information Year 2018 2017 2016 Land Value $565,042 $565,042 $565,042 Building Value $384,026 $387,507 $390,990 XF Value $12,299 $12,431 $12,564 Market Value $961,367 $964,980 $968,596 Assessed Value $783,776 $767,656 $751,867 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $177 591 $197,324 $216,729 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead I Exemption 1 $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description M SHORES BAY PK ESTS PB 55-83 LOT 1 BILK 4 LOT SIZE 11415 SQ FT OR 20249-2757 03 2002 1 COC 25664-2693 05 2007 1 Generated On : 5/23/2019 Taxable Value Information 2018 2017 2016 County Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $733,776 $717,656 $701,867 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $758,776 $742,656 $726,867 City Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $733,776 $717,656 $701,867 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $733,776 $717,656 $701,867 Sales Information Previous Sale Price OR Book -Page Qualification Description 05/01/2007 $1,100,000 25664-2693 Sales which are qualified 03/01/2002 $582,500 20249-2757 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: Section AB MIAMP ADE Miami -Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" RECEIVED Section A (General Information) ,1 N 2 5 2019 �r Master Permit No: Process No: T ---- _ _ _ - BY: Contractor's Name: T AND S ROOFING 10221 ne 13 ave Job Address: Roof Category q - ❑ Low Slope ❑ Mechanically Fastened Tile ❑✓ Mortar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Other: Roof Type ❑ New Roof ❑ Re -Roofing ❑ Recovering ❑✓ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes ❑✓ No If yes, what type? ❑ Natural • 0 LPGX Roof System Information . . 000000 --. .... Low slope roof area ft') 0 Steep Sloped area ft') 50 Total (ft.2) 5A • • • • • • • � • • • • � • Section B (Roof Plan) • • • • • • .... ..... Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overfow dra.ins.. nclude • dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and locp1i; of paraptts • • • • • • 00 Perimeter Width (a'): �Corner Size (a' x a'):0 �T (.-6 -1 J I W �1 Q � r I Tile Roof System P=:IAMI-DADE Miami -Dade County HVHZ Electronic Roof Permit Form Section D Tile Roof System "Delivering Excellence Every Day" Roof System Manufacturer: BORAL ROOFING Notice of Acceptance Number (NOA): Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P 1: 39.1 P 2: 68.1 P 3: '100.7 Maximum Design Wind Pressures, (From the NOA Specific system): '26 1 psf Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Roof Slope: "M2" Roof Mean Height: 5 _. _ ft. Method of Tile Attachment: Adhesive, 2 Small Paddy Polyfoam Polypro- Alternate Method of Tile Attachment per NOA: Drip Edge Size & Gauge: --3" face 26 ga.al — Drip Edge Material Type: I --Galvinized Metal_ - Deck Type: 1,--50 Plywood — Optional Insulation: Optional Nailable Substr4e:.'. ...... .. . ..... Optional Nailable Substrat Npehmenl; • •••••• Basesheet Type: 0 • • • • : • 30 ASTM TYPE II •�• �••••� • • Fastener Type for Basesheet Attachment: 30 ASTM TYPE II Tile Underlayment (Cap Sheet) Type: ILE SEAL Tile Underlayment Attachment Method: SELF ADHERED Drip Edge Fastener Type: ;1 114 IRS . NAILS Tile Profile: 'VILLA 900 Hook Strip/Cleat gauge or weight: -- Select Hook Strip -- Section E r •Y MIAMI•DADE LICAUUM "Delivering Excellence Every Day" Miami -Dade County HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: 39.1 x X j.315 _ 12.31 - Mg: 7.50 = Mr1: i4.81 < i26.1 NOA Mf P 2: 68 �. _. _ x 7v .31.5 .. = 21.45 - Mg: _50 = Mr2: !13.95 < 26.1 NOA Mf P 3: j100.7 x X.315 = '31.72 - Mg: 7.50 = Mr3: 24.22 ' �26.1 NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127" For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. P1:XI:�=Xw:=-W:=® XCos A:71=Fr1: . . .... ...... V' .��dAF'VVVV-....:. P2 x1: Xw: = -W: =� XCos 0: =Fr2: .... .�NQAF' �....� P3: X1:�= Xw:�= -W:�=� Xcos 0:=Fr3: .... �' NOAF' ..:..� .. .. .. . ...... Where to Obtain Information to complete tile calculations : ....:. Description Symbol Where to Find Design Pressure P1 or P2 or P3 Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height H Job Site Roof Slope a Job Site Aerodynamic Multiplier x Product Approval (NOA) Restoring Moment due to Gravity Mg Product Approval (NOA) Attachment Resistance Mf Product Approval (NOA) Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval (NOA) Tile Dimensions I =length w = width Product Approval (NOA) MI® DARE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidaae.aov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. .... This product is approved as described herein, and has been designed to comply with the Florida Building Cede' ...... including the High Velocity Hurricane Zone of the Florida Building Code. 0..0• •••••• •• • •••••• • DESCRIPTION: Boral Villa 900 Concrete Roof Tile """ 0. ' • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo oily tate and folloOGGwing • • 9 • • • 000*0 statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein..'.. ; ...... RENEWAL of this NOA shall be considered after a renewal application has been filed and there tas been no•chang • in the applicable building code negatively affecting the performance of this product. 0 • 0 0 0 a 0 0• • . •••••• 0 GO TERMINATION of this NOA will occur after the expiration date or if there has been a revision or char%giarhe • materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.16-0711.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Sernino 0 NOA No.: 18-0509.16 MIAMI•DADECOUNTY Expiration Date: 09/21/21 • Approval Date: 06/28/18 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Boral Roofing Villa 900 Length = 17" TAS 112 Width = 13" Type lb %" thick Class III Trim Pieces 1= varies TAS 112 w = varies varying thickness 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BOND' Roof Tile Adhesive "Tile Tite" Roof Tile Mortar DAP Foam Touch N Seal StormBonO 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Product Description Low profile, interlocking, high pressure extruded concrete roof tile equipped with three nail holes and double rolls. For direct deck, batten, mortar or adhesive set applications. 000000 Accessory trim, concrete roof pieces Tor use at.... V ridges, hips and rakes - 06 •••••• • • Single component polyurethane foam roof tile adhesive. Premixed, pre -bagged roof tile mortar. Two component polyurethane foam adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL .••••• ...... . ... ..... Manufacturer • • ...... (With:ftrrCnt NOA)• • • . . . . ...... ICP Adhesives apd Seal:nt *, "c. • .. . . •• •••• The Dow Chemical Company Bermuda Roof Co. Inc. The Dow Chemical Company NOA No.: 18-0509.16 MIAMI•DADECOUNTY Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 2 of 7 2.3 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Nutting Engineers 13343.1 TAS 112 Apr. 2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix Ill TAS 102 & TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix H TAS 108 (Nail -On) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied 94-060B Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set), Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) The Center for Applied Project No. 307025 Wind Driven Rain . `�Q4.2994 ...... Engineering, Inc. Test #MDC-76 TAS 100 0 The Center for Applied 25-7183-1 Static Uplift Testing :,:,: Neb. 1995 Engineering, Inc. 25-7183-2 TAS 102 .... .. . ; • • • •; (2 Quik-Drive Screws, Direct Davlk '..' ..... The Center for Applied 25-7214-2 Static Uplift Testing ➢✓taAM 1995 Engineering, Inc. 25-7214-6 TAS 102 • (1 Quik-Drive Screw, Direct D&4 ....;. (1 Quik-Drive Screw, Baltens�. ' Celotex Corporation 528454-2-1 Static Uplift Testing : Scpo.' 1998 ' Testing Services 520109-2 TAS 101 Deco 1998 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 Walker Engineering, Inc. Evaluation Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations Restoring Moment Due to Gravity 09/01/16 American Test Lab of South RT0617.02-16 TAS 112 06/29/16 Florida NOA No.: 18-0509.16 MIAMI•DADECOUNTY Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 3 of 7 2.3 EVIDENCE SUBMITTED Test Agency Test Identifier PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies COPO-002-02-11 COPO-002-02-04 COPO-002-02-03 Test Name/Report Date Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix W. Such testing shall be submitted to the 13uildiiig Cod' *Q"oaiplianc e� • • Office for review. • • • • • • . • 3.4 Minimum underlayment shall be in compliance with the applicable Roofing AAAMIfons St3fidartls listttl• • • • .... section 4.1 herein. • • • • • • .. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to tte•roef slope unless stated..e otherwise by the underlayment material manufacturers published literature.00 • • • • • • • • • • • • • • 3.6 This acceptance is for wood deck applications. Minimum deck requirements shQL jb• in compliance with • applicable building code. • . . . . ...... 4. INSTALLATION • • • 4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-1 (ft) Width-w (ft) Villa 900 Concrete Tile 10.90 1.42 1.08 Table 2: Aerodynamic Multipliers - I (ft3) Tile Profile X (ft3) Batten Application X (ft3) Direct Deck Application Villa 900 Concrete Tile 0.291 0.315 Table 3: Restoring Moments due to Gravity - M9 (ft.-lbf.) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Villa 900 Concrete Tile Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens I Direct Deck Battens Direct Deck 7.70 7.62 6.56 7.50 6.42 7.34 6.26 7.15 6.08 6.95 IN".A 1NU.. 10-0007..LU MIAMWADECOUbn Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" plywood) (min. 19/32" plywood) Villa 900 2-10d Ring Shank Nails 27.8 37.4 28.8 Concrete Tile 1-10d Smooth or Screw 8.8 11.8 4.1 Shank Nail 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail Field Clip) 1-10d Smooth or Screw 19.0 19.0 ...22.1 Shank Nail Eave Clip)_•••••� ••• 2-10d Smooth or Screw 35.5 35.5 • • � • •;34.8 Shank Nails Field Clip)""" " ' 2-10d Smooth or Screw 31.9 31.9 "" • • %2.2 • • Shank Nails Eave Clip - Table 5: Attachment Resistance Expressed as a Moment Mf•(fNbk '..' ... for Two Paddy Adhesive' Set Systems ; • •; •; • Tile Tile Application Minimum 4 tmilment• Profile ' • •' Resistanoe Villa 900 Concrete Tile The Dow Chemical Company TileBond 26.4 • • ICP Adhesives Polyset® AH-160 two- 26.13 component foam DAP Foam Touch N Seal StormBond ® 2 Roof 55 a Tile Adhesive two -component foam 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBond one -component foam, minimum weight per paddy 11.4 grams. 3 ICP Adhesives Polyset® AH-160 two -component foam, minimum weight per paddy 8 grams. 4 DAP Foam Touch N Seal StormBond ® 2 Roof Tile Adhesive, average weight per paddy 8 grams, two component foam. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Tile Application Profile Villa 900 Concrete Tile ICP Adhesives Polyset® AH-160 two -component foam ICP Adhesives Polyset® AH-160 two -component foam Minimum Attachment Resistance 86.615 45.5 s DAP Foam Touch N Seal StormBond ®2 Roof Tile 407 Adhesive DAP Foam Touch N Seal StormBond ®2 Roof Tile 708 Adhesive NOA No.: 18-0509.16 MIAMI•DADE CC UNTY Expiration Date: 09/21/21 ' ' Approval Date: 06/28/18 Page 5 of 7 5 Large paddy placement of minimum 54 grams. 6 Medium paddy placement of minimum 24 grams. 7 Medium paddy placement of minimum 30 grams. 8 Large paddy placement of minimum 60 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Villa 900 Concrete Tile Mortar Sets 20.60 Tile-Tite Roof Tile Mortar. 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's n dr o as eta led below *: �. 1Dg 5�..3 �. or following statement: "Miami -Dade County Product Control Approved". ...... 0 0 0 0: ....;. ...... . .... . .. ..... ...... . ... ..... .. .. .. . ...... . . . . ...... LABEL FOR BORAL VILLA 900 CONCRETE TILE " ; .". ' • (LOCATED ON THE UNDERSIDE OF TILE 6. BUILDING PERNUT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 18-0509.16 MIAMI-DADECOUNTY Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 6 of 7 [Vail hales to 1 I PROFILE DRAWING L12 1 1/etc VILLA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE Overlock NOA No.: 18-0509.16 MIAMI•DADE COUNTY Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 7 of 7 }M�IA�MI•DADE L1♦113i! DEPARTMENT OF BOARD AND CODE AD NOTICE OF Boral Roofing LL 7575 Irvine Cente Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Prpd}1ct Co• ntrol�ection•..... •. (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve tlferight to hgte:liis product or material tested for quality assurance purposes. If this product or material fails to*T)`ert'orm in the 1cctpted ""' • manner, the manufacturer will incur the expense of such testing and the AHJ may immediately jivoke, modify, or .... suspend the use of such product or material within their jurisdiction. RER reserves the riglft�p jvboke tjlis% ptance + • • if it is determined by Miami -Dade County Product Control Section that this product or matoiiaL"Is to meet the ..:..' requirements of the applicable building code. ""•• This product is approved as described herein, and has been designed to comply with the FI(Vd$ Wilding Cede • including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-0502.03 MpMI•DADE COUNTY Expiration Date: 08/02/23 UVIMII Approval Date: 08/02/18 Page 1 of 4 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 MINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 ACCEPTANCE (NOA) www.miamidade.gov/econoniy C. r Drive, Suite 100 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Product Dimensions BORAL TileSeal 36" x 36' rolls 36" x 72' rolls Boral Citadel Plus 36" x 72' rolls MANUFACTURIGN LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: Test Aaencv PRl Construction Materials Technologies, LLC. Trinity ERD Test Product Specification Description TAS 103 SBS self -adhering asphalt sheet material with a ASTM D 1970 white glass re -enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. ASTM D1970 Test Identifier OCF-356-02-04 OCF-356-02-02 OCF-356-02-01 OCF-424-02-04 OCF-424-02-01 OCF-424-02-03 BRLRF-SC 16810.11.17 SBS self -adhering asphalt sheet material with a poly film -facer; for use as a mid ply uuderlayment in sloped roof assemblies. • • • • • .. ...... ...... .. . ...... .... . .. ..... ...... . ... ..... .. .. .. . ...... Test Name/Repo zt .... bete • • • • ASTMD1623 �••� 47d25/18:�••�: TAS 103 •OW24/18 ASTM D1970 07/26/18 ASTM D1623 07/25/18 ASTM D1970 07/25/18 TAS 103 07/25/18 ASTM D 1876 11/28/17 NOA No.: 18-0502.03 MIAMI•DADE CC, TY Expiration Date: 08/02/23 "'' ' Approval Date: 08/02/18 Page 2 of 4 0 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D226 Type lI or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current approval. (Optional): Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the meuihrane is applied. Vertical strapping of the roof with BORAL TileSeal Undwlayment is aooepta•ble. Ake 0 0 0 end laps and laps without black selvage area shall be sealed under lap -ling an �BS:mpdified •, ...... .. . ...... mastic. • ...... 00 Note: When used in Tile roof systems BORAL TileSeal Underlayr%ijij s tall be �attpailed ;o • • • • deck with approved annular ring shank nails and tin caps at a maxin iuu l2" O.C. at tj side . •, •. • laps. No nails or tin caps shall be exposed. • • • • • • 000000 ...... for Adhered Roof Tile using TILE BOND or AH-160, Nfechanfeally ZWS :ed Rode 0':- Surfacing: Approved Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shing:e a rsomblie '. :.... • • ..0000 NOA No.: 18-0502.03 Iff-MIAMI-DADE Expiration Date: 08/02/23 • ' Approval Date: 08/02/18 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. • .. • 8. Tiles shall be stored on battens on roof pitches greater than 6:12". *fee • • • • • • 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Ace�'tance Witt - fee • ...... BORAL TileSeal underlayment as a component part of an assembly in the Notice of Ac;etdn�e. If BtfRAL • TileSeal underlayment is not listed, a request may be made to the Authority Having Juris�jVn (AHJJ or •the : • • • • Miami -Dade County Product Control Department for approval provided that appropriate doaut%entattoi? iS • sees* provided to detail compatibility of the products, wind uplift resistance, and fire testing remitse: •. :.: ..:..' 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loos!decicing pan8r . Sweep• • • 0 ; • the deck thoroughly to remove any dust and debris prior to application. . • • • . . . ...... 11. When applying the membrane in the valley, start at the low point and work to the high point rolling VVA&Inbran;• from the center outward in both directions. For ridge applications, center the membrane Q roll from the enter . outward in both directions. • 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below MIAMI•DADE COUNTY ,...I 1 END OF THIS ACCEPTANCE NOA No.: 18-0502.03 CAMIMIAMI-DADE COUNTY Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 4 of 4 MIAMI-DADE COUNTY MIMMi•L'�AM PRODUCT CONTROL SECTION a ! 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) it-Nvw.nrianudade.2ov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the acceptoAwianner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,emodiV, or suspevia the uee..�. of such product or material within their jurisdiction. RER reserves the right to revokL•thiS acceptatue, if it is • • determined by Miami -Dade County Product Control Section that this product or material fa1?VV?heet thefegdiremeiitS• •. • of the applicable building code. • • • • • • This product is approved as described herein, and has been designed to comply with •tip*•Trrorida Wuilding Cade... including the High Velocity Hurricane Zone of the Florida Building Code. • • • • • • • • • • • • • • .. .. .. . ...... DESCRIPTION: ICP Adhesives Polyset® AH-160 • • • • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logd,'cil, state apdofpllowiiig • statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. 0000 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications ICP Adhesives N/A TAS 101 Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPacke N/A 30 & 100 P CTS MANUFACTURED RV OTHERS• Product Description Two component polyurethane foam adhesive . .... ...... Dispensing Equipment • • • • • • • • • • • • • • • Dispensing Equipment • • .... • .. .. •• . ...... . . . . ... • • • RODU Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current N(50P whnch list at: iehment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. .. • • MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @1580F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MIAMI-DARE COUNTY Expiration Date: 05/10/22 �Fg...• Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier Test Name/Report Date #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 NB-589-631 ASTM D 1623 02/01/94 9637-92 ASTM E 108 04/30/93 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 O1`l�495 . . ... • • Gee*:* 7050.02.96-1 TAS 114 '..' O-VI4196 . P36700.04.12 ASTM D 1623 • • • • • • 64 1A/1*42 ..... • P39740.02.12 TAS 101 •••�•• 02/2t/12 ;�••.; TAS 123 .•"'. :'. '. ' .... . .. ..... • 528454-2-1 TAS 101 **:Go: 10%2�% .. .. .. . ...... 528454-9-1 ' 528454-10-1 . . •. ..... 520109-1 TAS 101 i7lAt . . . ...... 520109-2 •• 0 ' 520109-3 " " 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LEMTATIONS : 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI-DADE COUNTY �Fjuuq(lynjj� NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset AH-160 may be used with any roof file assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained -between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset AH-160 shall be applied with ICP Adhesives Foam Dispenser RTgL100 or Adhesives ProPack® 30 & 100 dispensing equipment only. ...:.. 7. ICP Adhesives Polyset AH-160 shall not be exposed permanently to sunlight. •••• • .. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes iffe; JCP Adhesives Polyset AH-160 has been dispensed. • • • • • • • 9. ICP Adhesives Polyset AH-160 placement and minimum patty weight shall be in acco;aw with the • • 'Placement Details' herein. Each generic tile profile requires the specific placement noted he{em. ; • • • • • NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 �F-1WJ31rJq11 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Minimum Paddy Contact Minimum Paddy Gram Tile Profile Placement Detail Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of file 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each • • • • bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 1 • ; 034 grams under pan* • • ..... LABELING: • ...... . ... ..... All approved products listed herein shall be labeled and shall bear the imprint or identifiable Mark?ng of thy' manufacturer's name or logo and following statement: "Miami -Dade County Product Contro;Approved" or the Miami- • • . . . . ...... Dade County Product Control Seal as shown below. PO MI43SOE C • • • •••• BUILDING PERMIT REQUEREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 MIAMNDADECOUNTY Expiration Date: 05/10/22 "' • ' Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 iti2avirough plastic.umcnt _ Fai+lJy R?r��caslt�3si y�fi'�Ytxl rl3gUIPQdY !�`-^' t '? klir:lgtlaymeric 1�+1n c.r�._"�:X"-...'� �!t 1 waslesscptia-lid EvoCluiurr--z �' r•• KS' -,i- Mail through glarlic comer d iwhm rrgvlri di i r lwddyOwmathTim kle�d•rlaytnagrE t. f �,,. � ^`'••,.- f IQ ln.x ttmsrss ol>±i±rnal _ t � ••`-,1�^ :• �'•.+�� a' I >., k. Ea." closure Easie {�srrsc - - ' -"-'��ff •�'' -- Fase3a P14V 6u9hOR.siEav rii••, RaddylBen.•ilsxl«I tM&ertraCLUrte1 Undel•yic�srL # c + 1 a'• ``ham a`. -•..�4>_ r,�:=— €a'.CourWin. 2 se --,�.�,�� tjn;.r•,' ,,s`;-- .= ' €aster •� -�,f ri fa9+- cl+asrrte ,4• t_ r' Imp t119t MIAMI•DADE COUNTY �Fnjglrapl Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayinent positioned as shown, under the strengthening rib closest to the Overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile ."". 1. Starting at the eave cour%e, �ppiy a mi iimum 2" • • • . (50.8 mm) x 10" (254 niglX j.' (25.4 mrq) foam • paddy onto the underlaymelatpositioned asshown;""; under the pan portion of th&W closest to•the • • • • . • • Overlock of the tile beingg64t • • • • • • • • • • •• of •• • •••••• 2. Continue in same mannetTAMe approximately 17 (109.7 cm2) — 23 (148.4 cm2) square ilsah a2kesive "• • • contact with the undersidegttlT tile. , • • :'''': High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the Overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 A1` i1 Glfizimgk p a:.iF 4rinepe p%!�k1� 1$i.tjRr7F�7elfj FJ.^rdBf'�ifntORS y `"i t i� in- t A:Z #. ~�- fy +�v Fes• .µ 4; ,.• .. `mil .• - it _. Nail throwlt Plastic —Itt Ober regniredl U�ad�ela�tapnt `•� •`"� :�� Pin �- _ i _ •e- 1 � •_Lk_ i AF x L' _ :� x= MIAMI•DADE CO�FjUNTY • • Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 nun) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm'-) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm.) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the file being set. •..• 3. Continue in same manner. :nsiptapproximately 10"6 • • •; • (64.5 cm2) - 12 (77.4 cm2) s4tiareinch 4M$%e •. contact with the underside ot'ttetile. .... . .. ..... Medium Profile / Double Pan Ti1n. . ... ..:..' 1. Starting at the eave courseia"15:a minimum 2" (50.8 • mm) x 10" (254 mm) x 1 " t25.4 fhm) fU-�i.iWdy • • • • • • onto the underlayment positioVdas shown under thg....; pan portion of the tile closest to tfie ove locVaf the tile being set. Insure approximately 17 (Mrl cm2) — 23 (148.4 cm'-) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) ti%4,em required 1 pd,14 farr.. hTilri z {i4. _ fit.. ��+`4 • f�. YY :B:i;teai [Y,p[IaiSn{ J�o. •..ti'` :•'._, •"'.t � X•,:' ii E-VIIC,ms—��`"— M1.= .' Eric+a 'Wrophc]e 'Eaw LEoswe 1Pn-, Zia. '�+' '' rF L ter' blipedge M{AM -DADE COUNTY . ....a 1 High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 inm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. PsWt approxtmiLtely 17"- • • • ; • (109.7 cm2) - 19 (122.6 cin j %quftre incj AVesive contact with the underside of tte lile. ' • • • • • • • • 660*6 0000..... ...... . ... ..... .. .. •• • ...... . . . 0000% •• . . •• • • . . NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Mail through plastic cernent Paddy (between tiles) ;when requiredli Battens optional t+ Paddy lunderfile) Singlepaddy r on top of tile slepad im EY ll Single paddy _ `+ on undedayment 2 n d in. � r io f' Fa ��an. asci •--EaveClosure Flat/Low Profile Tile Wall through plasticeement Sngiepaddy under tile when required] Paddy lbetrs*een tiles] t Battens Paddy (under tie] optional f � ' Siogie paddy ��.an top oft le---. � z41n, 2s4in.`�. Singg6e paddy on undartaymerrt 2in. Eave Closure Eave Course fascia MLLdlum Pro#ileTile MIAMI•DADE COUNTY 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam giddy under the strengthening�rib fQr flat til�,.gr•-trader tag• • pan portion of the tile, c'losdstxo the u"],prlock for , • the second course file ta► beiustalled' 1ngule • • • • : • approximately 8-9 in (5}.4§8.1 cm2) of adhesive • contact with the undersWC-P the tile; • • • . • •••• • •• ••••• ...... .... ..... .. .. .. . ...... (Instructions continued on 71gjPape) • • • • • • •••••• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail throughplasGtzz 7t Senrlepaddy under lile Jwhe!n xe4uUedj f 'Paddy (between [ifes) Battens optional Paddy Wndertilel qr_ r iirigle ddy on UndtiiiYMErn dxdin. 3ingie 2 x d in. paddyone'`,. topofiiie= •� �� �/' Save Course f Fasda Weephole E.-ve dosure 10 in. 2 in. Drip edge e High P.rofiloTile QMIAMMI-D�ADECO=U VIM .• M 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 nun) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm) - 9 (58.1 cm) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • • •••••• •• • •••••• • •••••• •••• • •• ••••• •••••• • ••• ••••• • • • • • •• •• •• • •••••• • • • • • •••••• • • • • •• • • •• • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 1) Place enough adhesive to achieve 65 to 705 in contact with the pan tile. 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. ° Underlayment f ' Fascia Board ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Steep pitch applications (when required) Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave fine. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm') — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. sees 3. Turn covers upside dawn exeosing the uddersidese e .. of the tile. Apply a min:mun! 1" (254mam) x 10" .' (254 mm) bead of adheshrdirectly on the inner • • • : • edge of each side of tlfeldddr tile. Leave •; approximately 3/4" (IP*Ali*�to 1";25.4'mm) ' from the outside edge ot�i� •tile, inwar4 free of . foam to allow for exp4iaSi94! • • • • ; 00*00 0 0.0 • • 4. Turn cover tile over after foam is a�lied .... and . , ..:. . place onto pan the coarse ..k;sure amimmum of* • • • 20 (129 cm2) -25 (161.5•cm33) squ4e jne13 • contact area on each side of the covd i'CM to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF TIUS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11