RF-19-1457Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
Issue Date: 07/02/2019
Parcel Number
10221 NE 13TH AVE, Miami Shores, FL 33138 1132050230150
Contacts
Permit NO.: RF-06-19-1457
Permit Type: Roof
Work Classification: Repair Roof
Permit Status: Approved
Expiration: 12/30/2019
MARIA SUAREZ Owner
10221 NE 13 AVE, MIAMI SHORES, FL 33138
Home: 305-308-5040
T&S ROOFING SYSTEMS INC. Contractor
LOUIS TOLEDO
1461 NW 23 ST, MIAMI, FL 33142
Business: 3052652654
Other:3057727954
Description: TILE ROOF REPAIR Valuation: $ 2,200.00 Inspection Requests:
Total Sq Feet: 50.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$1.80
DBPR Fee
$3.75
DCA Fee
$2.50
Education Surcharge
$0.60
Roofing Fee
$50.00
Scanning Fee
$12.00
Technology Fee
$6.25
Total:
$126.90
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$126.90
Check # 36415
07/02/2019 $126.90
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate
regulating construction and zoning. Futhermore, I authorize the above named i
that all work will be done in compliance with all applicable laws
jr to do the work stated.
1- _L0\
Authorized Signature: Owner / Applicant / Contractor / Agent
Date
July 02, 2019 Page 2 of 2
RECEIVED
(IzSV
BUILDING
PERMIT APPLICATION
Miami Shores Village iu 2 019
Building Department BY:
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
FBC 20 I�
Master Permit No. —cj6 (gi - J L4 5�
Sub Permit No.
❑BUILDING ❑ ELECTRIC 1� ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: N Z
Citv: Miami Shores
Folio/Parcel#:At
Occupancy Type: _
0z - 0 in Is the Building Historically Designated: Yes NO _
Load: Construction Type: Flood Zone: BFE: FIFE:
OWNER: Name (Fee Simple Titleholder):
Address: �,2I g I'
Phone#: -30EZ_+C-7
City: %Ye� (, State: _ Zip: J 1 �b
Tenant/Lessee Name: Phone#:
Email:y(p oS-
CONTRACTO : C mpany 'Na..m11e: G�i l� ` Phone#: �k J I
Address: W
City: Stater Zip:
Qualifier N me: 001S Phone#:
State Certification or Registration #: v Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: /� City: State: Zip:
Value of Work for this Permit: $I -Zoo Square/Linear Footage of Work: -1)0 !�qjE± -
Type of Work: ❑ Addition ZI Alteration ❑ New ❑ Repair/Replace ❑ Demolition
Description of Work:
Specify color of color thru tile:
Submittal Fee $ Permit Fee $ CCF $ CO/CC $
Scanning Fee $ Radon Fee $ DBPR $ Notary $
Technology Fee $ Training/Education Fee $ Double Fee $
Structural Reviews $ Bond $
TOTAL FEE NOW DUE $ (V
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City State
Mortgage Lender's Name (if applicable) _
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
OWNER or AGENT
The foregoing instrument was acknowledged before me this
�-5 day of 20 , by
who is personally known to
me or who has produced
identification and -who did take an oath.
NOT
Sign
Notary public State of Florida
David Alexander Carrasco
• 3 ! r ....r..iaaien GG2241618
as
Signatu
CONTRACTOR
The foregoing in 1(rument wa`s Aacknowledged before me this
Of vv 20, by
( who is personally known to
me or who has produced as
identification and who did take an oath.
NOT R %UBLI ,�w Notary Public State or Florida
+� �� David Alexander Carrasco
� MY Commission GG 241618
1 �� � Expires 0712512022
Print: 1 I M�� sG v Prin . 1 �01 7) CQ
Seal: Seal:
APPROVED BY ?4VZ1
y Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
,
Page 1 of 2
Manuel J. Vaditta, Esq.
Snnclttc va ditto LLP
11402 INW4111 Street, Set202
Durtr, Ft.33178
VR-1940. 6
Return iD;
CM11a Armenteros, F-sq.
Armentem, Low, P.A.
9054 Pines t11vd., Suite 336
Ptmbrake Pine$, R. 3.1924
Paw) Idmificeticm Nw I I.3-05-023-0150
CW 20190258316 BOOK 31418 PAGE 725
DATE:04M/2019 08:13:A1 AM
DEED DOC 99,300.00
IIARVEY RUVIN, CLERIC OF COURT, MIA-OACE CTY
e ism t one rw ILe _kV
WARRANTY DEED
(STATUTORY FOX.M - SCCTION W,02, F.S.)
This indenture made the ..G day of April, 2019 between Marix Suarez afic/n Maria C. Suarez,, a
sing to woman, whose post office address is 973 NE 96" Street, Miami Shores, FL 33138, Grantor, to
DONALD E. C1HAK Trust dated December 27, 2007, as further amended and restated, whose post
office address is 10221 NE 13`s` Avenue, Miami Shores, FL 33138, of the County of Miami Dade, Florida,
Grantee.
Witnesseth, that said Grantor, for and in consideration of the sutra of TEN DOLLARS (U.S. S10.00) and
other good and valuable considerations to said Grantor in !land paid by said Grantee, the receipt whereof is
hereby acknowledged, has granted, bargained, .and sold to the said Grantee,, and Grantee's !heirs and assigns
forever, the fallowing described land, situate; lying and being in Miami -Dade, Florida, to -wit:
Lot 1, Block 4, of MIAMI SHORES BAY PARK ESTATES, according to the plat thereof, as
recorded in. Plat Book 55, Page(s) 83, of the Public Records of IN-fland-Dade County, Florida.
Also known as 102.21 NE 1.31b Avenue, Miami Shores, FL 33138
Parcel Identification Number: 11-1205-023-0150
Together with all the tenements, hereditaaTments and appurtenances thereto belonging or in anywise
appertaining.
Subject to taxes for 2019 and subsequent years. not yet due and pay -able; covenants, restrictions, casemewts,
reservations and limitations of record, if any.
TO HAVE AND TO HOLD the same in fee simple forever.
And Grantor hereby covenant with the Grantee that the Grantor are lawfully seized of said land in fate simple,
that Grantor have good right and lawful authority to sell and convey said land and that the Grantor hereby fully
warrant the title to said land and will defend the same against the lawful claims of all persons whomsoever.
watmwy ocm
Pate I tail
https:Honlineservices.miami-dadeclerk.com/officialrecordslCFNDetailsHTML5.aspx?QS=... 5/24/2019
•
Page 2 of 2
CFN: 20190256315 BOOK 31418 PAGE 725
In Witness Whereof, Grantor have hereunto set Grantor's hand and seal the day and year first above
written.
Signed, sealed and delivered in olrr pretence.
6
Marfa Suarez alk/a Maria C.
STATE .FLORIDA
COUNTY OF MIA -MI -DADS
The foregoing instrument was acknowledged before me this vt�', ay of Apia, 2019, by Maria. Suarez aWa
Maria C. Suarez, who is,persrs 11 �knqwr� to me„or who produced a as
identifiicat' n
Signat f N& public �'~`` `'w YAIUANA LEYVA
r .State of € oridat-MKary Public
Print. "t ypelStarn t, of Notary y caMmtasior, r cG 213028
..�.'� My Corm S4f 2032piies
Personally known: V
OR Produced Identification:
Type of Identification Produced:
YasM"Oyrxkd
1"Ve 2 of 2
https://onlineservices.miami-dadeclerk.com/officialrecordslCFNDetailsHTML5.aspx?QS=... 5/24/2019
I 1 , I' . dF
Summary Report
Property Information
Folio:
11-3205-023-0150
Property Address:
10221 NE 13 AVE
Miami Shores, FL 33138-2637
Owner
MARIA SUAREZ
Mailing Address
10221 NE 13 AVE
MIAMI SHORES, FL 33138-2637
PA Primary Zone
1400 SGL FAMILY - 3001-3250 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
3/2/1
Floors
1
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
3,164 Sq.Ft
Lot Size
11,415 Sq.Ft
Year Built
Multiple (See Building Info.)
Assessment Information
Year
2018
2017
2016
Land Value
$565,042
$565,042
$565,042
Building Value
$384,026
$387,507
$390,990
XF Value
$12,299
$12,431
$12,564
Market Value
$961,367
$964,980
$968,596
Assessed Value
$783,776
$767,656
$751,867
Benefits Information
Benefit
Type
2018
2017
2016
Save Our Homes
Cap
Assessment
Reduction
$177 591
$197,324
$216,729
Homestead
Exemption
$25,000
$25,000
$25,000
Second Homestead
I Exemption
1 $25,000
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
Short Legal Description
M SHORES BAY PK ESTS PB 55-83
LOT 1 BILK 4
LOT SIZE 11415 SQ FT
OR 20249-2757 03 2002 1
COC 25664-2693 05 2007 1
Generated On : 5/23/2019
Taxable Value Information
2018
2017
2016
County
Exemption Value
1 $50,000
$50,000
$50,000
Taxable Value
1 $733,776
$717,656
$701,867
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$758,776
$742,656
$726,867
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
1 $733,776
$717,656
$701,867
Regional
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$733,776
$717,656
$701,867
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
05/01/2007
$1,100,000
25664-2693
Sales which are qualified
03/01/2002
$582,500
20249-2757
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
Section AB
MIAMP ADE Miami -Dade County HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day" RECEIVED
Section A (General Information) ,1 N 2 5 2019
�r
Master Permit No: Process No: T
---- _ _ _ - BY:
Contractor's Name: T AND S ROOFING
10221 ne 13 ave
Job Address:
Roof Category q -
❑ Low Slope ❑ Mechanically Fastened Tile ❑✓ Mortar/Adhesive Set Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Sprayed Polyurethane Foam ❑ Other:
Roof Type
❑ New Roof ❑ Re -Roofing ❑ Recovering ❑✓ Repair ❑ Maintenance
Are there Gas Vent Stacks located on the roof? ❑ Yes ❑✓ No If yes, what type? ❑ Natural • 0 LPGX
Roof System Information . . 000000
--. ....
Low slope roof area ft') 0 Steep Sloped area ft') 50 Total (ft.2) 5A • • • • • • • � • • • • � •
Section B (Roof Plan) • • • • • •
.... .....
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overfow dra.ins.. nclude •
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and locp1i; of paraptts • • • • • •
00
Perimeter Width (a'): �Corner Size (a' x a'):0
�T
(.-6
-1
J
I W �1
Q �
r
I
Tile Roof System
P=:IAMI-DADE
Miami -Dade County HVHZ Electronic Roof Permit Form
Section D Tile Roof System
"Delivering Excellence Every Day"
Roof System Manufacturer: BORAL ROOFING
Notice of Acceptance Number (NOA):
Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations):
P 1: 39.1 P 2: 68.1 P 3: '100.7
Maximum Design Wind Pressures, (From the NOA Specific system): '26 1 psf
Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box.
Roof Slope: "M2"
Roof Mean Height: 5 _. _ ft.
Method of Tile Attachment:
Adhesive, 2 Small Paddy Polyfoam Polypro-
Alternate Method of Tile Attachment per NOA:
Drip Edge Size & Gauge: --3" face 26 ga.al
—
Drip Edge Material Type: I --Galvinized Metal_ -
Deck Type: 1,--50 Plywood —
Optional Insulation:
Optional Nailable Substr4e:.'.
......
.. .
.....
Optional Nailable Substrat Npehmenl; •
••••••
Basesheet Type: 0
• • • • : •
30 ASTM TYPE II •�•
�••••�
• •
Fastener Type for Basesheet Attachment:
30 ASTM TYPE II
Tile Underlayment (Cap Sheet) Type:
ILE SEAL
Tile Underlayment Attachment Method:
SELF ADHERED
Drip Edge Fastener Type: ;1 114 IRS . NAILS Tile Profile:
'VILLA 900
Hook Strip/Cleat gauge or weight: -- Select Hook Strip --
Section E
r •Y
MIAMI•DADE
LICAUUM
"Delivering Excellence Every Day"
Miami -Dade County HVHZ Electronic Roof Permit Form
Section E (Tile Calculations)
Method 1 "Moment Based Tile Calculations Per RAS 127"
For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are
greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable.
P 1: 39.1
x X j.315
_ 12.31
- Mg: 7.50
= Mr1: i4.81 < i26.1 NOA Mf
P 2: 68 �. _. _
x 7v .31.5 ..
= 21.45
- Mg: _50
= Mr2: !13.95 < 26.1 NOA Mf
P 3:
j100.7
x X.315
= '31.72
- Mg:
7.50
= Mr3:
24.22 '
�26.1
NOA Mf
Method 3 "Uplift Based Tile Calculations Per RAS 127"
For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F values are greater than or equal to the Fr values, for
each area of the roof, then the tile attachment method is acceptable.
P1:XI:�=Xw:=-W:=®
XCos A:71=Fr1:
. . .... ......
V' .��dAF'VVVV-....:.
P2 x1:
Xw: =
-W:
=�
XCos 0: =Fr2:
.... .�NQAF' �....�
P3: X1:�=
Xw:�=
-W:�=�
Xcos 0:=Fr3:
.... �' NOAF' ..:..�
.. .. .. . ......
Where to Obtain Information to complete tile calculations
: ....:.
Description
Symbol
Where to Find
Design Pressure
P1 or P2 or P3
Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional
engineer based on ASCE 7.
Mean Roof Height
H
Job Site
Roof Slope
a
Job Site
Aerodynamic Multiplier
x
Product Approval (NOA)
Restoring Moment due to Gravity
Mg
Product Approval (NOA)
Attachment Resistance
Mf
Product Approval (NOA)
Required Moment Resistance
Mr
Calculated
Minimum Attachment Resistance
F'
Product Approval (NOA)
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval (NOA)
Tile Dimensions
I =length
w = width
Product Approval (NOA)
MI® DARE
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidaae.aov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code. ....
This product is approved as described herein, and has been designed to comply with the Florida Building Cede' ......
including the High Velocity Hurricane Zone of the Florida Building Code. 0..0•
•••••• •• • ••••••
•
DESCRIPTION: Boral Villa 900 Concrete Roof Tile """ 0. '
•
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo oily tate and folloOGGwing • • 9 • • •
000*0
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein..'.. ; ......
RENEWAL of this NOA shall be considered after a renewal application has been filed and there tas been no•chang •
in the applicable building code negatively affecting the performance of this product. 0 • 0 0 0 a 0 0•
• . ••••••
0 GO
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or char%giarhe •
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.16-0711.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Sernino 0
NOA No.: 18-0509.16
MIAMI•DADECOUNTY Expiration Date: 09/21/21
•
Approval Date: 06/28/18
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake
Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure
requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by
calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Applicant
Dimensions
Specifications
Boral Roofing Villa 900
Length = 17"
TAS 112
Width = 13"
Type lb
%" thick
Class III
Trim Pieces 1= varies TAS 112
w = varies
varying thickness
2.1 PRODUCTS MANUFACTURED BY OTHERS
Product Name
ICP Adhesives Polyset® AH-160
TILE BOND' Roof Tile Adhesive
"Tile Tite" Roof Tile Mortar
DAP Foam Touch N Seal
StormBonO 2 Roof Tile Adhesive
Product Description
Two component polyurethane
foam adhesive.
Product
Description
Low profile, interlocking, high pressure extruded
concrete roof tile equipped with three nail holes
and double rolls. For direct deck, batten, mortar
or adhesive set applications. 000000
Accessory trim, concrete roof pieces Tor use at.... V
ridges, hips and rakes -
06
•••••• • •
Single component polyurethane
foam roof tile adhesive.
Premixed, pre -bagged roof tile
mortar.
Two component polyurethane
foam adhesive.
2.2 MANUFACTURING LOCATION
2.2.1. Lake Wales, FL
.•••••
...... . ...
.....
Manufacturer • •
......
(With:ftrrCnt NOA)•
• •
. . . .
......
ICP Adhesives apd Seal:nt *, "c.
•
.. . . ••
••••
The Dow Chemical Company
Bermuda Roof Co. Inc.
The Dow Chemical Company
NOA No.: 18-0509.16
MIAMI•DADECOUNTY Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 2 of 7
2.3 EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Nutting Engineers
13343.1
TAS 112
Apr. 2006
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix Ill
TAS 102 & TAS 102(A)
Redland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix H
TAS 108 (Nail -On)
Redland Technologies
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
The Center for Applied
94-060B
Static Uplift Testing
March, 1994
Engineering, Inc.
TAS 101 (Adhesive Set)
The Center for Applied
94-084
Static Uplift Testing
May 1994
Engineering, Inc.
TAS 101 (Mortar Set),
Redland Technologies
P0631-01
Wind Tunnel Testing
July 1994
TAS 108 (Mortar Set)
Redland Technologies
Letter Dated Aug. 1, 1994
Wind Tunnel Testing
Aug. 1994
TAS 108 (Nail -On)
The Center for Applied
Project No. 307025
Wind Driven Rain .
`�Q4.2994 ......
Engineering, Inc.
Test #MDC-76
TAS 100
0
The Center for Applied
25-7183-1
Static Uplift Testing :,:,:
Neb. 1995
Engineering, Inc.
25-7183-2
TAS 102 ....
.. . ; • • • •;
(2 Quik-Drive Screws, Direct Davlk
'..' .....
The Center for Applied
25-7214-2
Static Uplift Testing
➢✓taAM 1995
Engineering, Inc.
25-7214-6
TAS 102
•
(1 Quik-Drive Screw, Direct D&4
....;.
(1 Quik-Drive Screw, Baltens�.
'
Celotex Corporation
528454-2-1
Static Uplift Testing
: Scpo.' 1998 '
Testing Services
520109-2
TAS 101
Deco 1998
Walker Engineering, Inc.
Evaluation Calculations
25-7183
March 1995
Walker Engineering, Inc.
Evaluation Calculations
25-7094
February 1996
Walker Engineering, Inc.
Evaluation Calculations
25-7496
April 1996
Walker Engineering, Inc.
Evaluation Calculations
25-7584
December 1996
25-7804b-8
25-7804-4 & 5
25-7848-6
Walker Engineering, Inc.
Evaluation Calculations
Aerodynamic Multipliers
09/01/16
Walker Engineering, Inc.
Evaluation Calculations
Two Patty Adhesive Set System
April 1999
Walker Engineering, Inc.
Evaluation Calculations
Restoring Moment Due to Gravity
09/01/16
American Test Lab of South
RT0617.02-16
TAS 112
06/29/16
Florida
NOA No.: 18-0509.16
MIAMI•DADECOUNTY Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 3 of 7
2.3 EVIDENCE SUBMITTED
Test Agency Test Identifier
PRI Construction Materials
Technologies
PRI Construction Materials
Technologies
PRI Construction Materials
Technologies
COPO-002-02-11
COPO-002-02-04
COPO-002-02-03
Test Name/Report Date
Static Uplift Testing 10/12/2016
TAS 101 (Adhesive Set)
Static Uplift Testing 10/12/2016
TAS 101 (Adhesive Set)
Static Uplift Testing 10/12/2016
TAS 101 (Adhesive Set)
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS
106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix W. Such testing shall be submitted to the 13uildiiig Cod' *Q"oaiplianc e� • •
Office for review. • • • • • • . •
3.4 Minimum underlayment shall be in compliance with the applicable Roofing AAAMIfons St3fidartls listttl• • • •
....
section 4.1 herein. • • • • • •
..
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to tte•roef slope unless stated..e
otherwise by the underlayment material manufacturers published literature.00
• • • • • • • • • • • • • •
3.6 This acceptance is for wood deck applications. Minimum deck requirements shQL jb• in compliance with •
applicable building code. •
. . . . ......
4. INSTALLATION • • •
4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing
Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lbf)
Length-1 (ft)
Width-w (ft)
Villa 900 Concrete Tile
10.90
1.42
1.08
Table 2: Aerodynamic Multipliers - I (ft3)
Tile
Profile
X (ft3)
Batten Application
X (ft3)
Direct Deck Application
Villa 900 Concrete Tile
0.291
0.315
Table 3: Restoring Moments due to Gravity - M9 (ft.-lbf.)
Tile
Profile
2":12"
3":12"
4":12"
5":12"
6":12"
7":12" or
greater
Villa 900
Concrete Tile
Direct
Deck
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
I
Direct
Deck
Battens
Direct
Deck
7.70
7.62
6.56
7.50
6.42
7.34
6.26
7.15
6.08
6.95
IN".A 1NU.. 10-0007..LU
MIAMWADECOUbn Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mechanically Fastened Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(min 15/32" plywood)
(min. 19/32" plywood)
Villa 900
2-10d Ring Shank Nails
27.8
37.4
28.8
Concrete Tile
1-10d Smooth or Screw
8.8
11.8
4.1
Shank Nail
2-10d Smooth or Screw
16.4
21.9
7.1
Shank Nails
1 #8 Screw
25.8
25.8
22.9
2 #8 Screw
47.1
47.1
49.1
1-10d Smooth or Screw
24.3
24.3
24.2
Shank Nail Field Clip)
1-10d Smooth or Screw
19.0
19.0
...22.1
Shank Nail Eave Clip)_•••••�
•••
2-10d Smooth or Screw
35.5
35.5 • •
� • •;34.8
Shank Nails Field Clip)"""
" '
2-10d Smooth or Screw
31.9
31.9 "" • •
%2.2 • •
Shank Nails Eave Clip
-
Table 5: Attachment Resistance Expressed as a Moment Mf•(fNbk '..' ...
for Two Paddy Adhesive' Set Systems ; • •; •; •
Tile
Tile Application
Minimum 4 tmilment•
Profile
' • •' Resistanoe
Villa 900 Concrete Tile
The Dow Chemical Company TileBond
26.4 • •
ICP Adhesives Polyset® AH-160 two-
26.13
component foam
DAP Foam Touch N Seal StormBond ® 2 Roof
55 a
Tile Adhesive two -component foam
1 See foam adhesive manufacturer's component approval for installation requirements.
2 The Dow Chemical Company TileBond one -component foam, minimum weight per paddy 11.4 grams.
3 ICP Adhesives Polyset® AH-160 two -component foam, minimum weight per paddy 8 grams.
4 DAP Foam Touch N Seal StormBond ® 2 Roof Tile Adhesive, average weight per paddy 8 grams, two component
foam.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Single Paddy Adhesive Set Systems
Tile Tile Application
Profile
Villa 900 Concrete Tile ICP Adhesives Polyset® AH-160 two -component foam
ICP Adhesives Polyset® AH-160 two -component foam
Minimum Attachment
Resistance
86.615
45.5 s
DAP Foam Touch N Seal StormBond ®2 Roof Tile
407
Adhesive
DAP Foam Touch N Seal StormBond ®2 Roof Tile
708
Adhesive
NOA No.: 18-0509.16
MIAMI•DADE CC UNTY Expiration Date: 09/21/21
' ' Approval Date: 06/28/18
Page 5 of 7
5 Large paddy placement
of minimum 54 grams.
6 Medium paddy
placement of minimum 24 grams.
7 Medium paddy
placement of minimum 30 grams.
8 Large paddy placement
of minimum 60 grams.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Villa 900 Concrete Tile
Mortar Sets
20.60
Tile-Tite Roof Tile Mortar.
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's n dr o as eta led below *:
�. 1Dg 5�..3 �.
or following statement: "Miami -Dade County Product Control Approved". ...... 0 0 0 0: ....;.
...... .
.... . .. .....
...... . ... .....
.. .. .. . ......
. . . . ......
LABEL FOR BORAL VILLA 900 CONCRETE TILE " ; .". ' •
(LOCATED ON THE UNDERSIDE OF TILE
6. BUILDING PERNUT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.: 18-0509.16
MIAMI-DADECOUNTY Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 6 of 7
[Vail hales
to 1
I
PROFILE DRAWING
L12
1 1/etc
VILLA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
Overlock
NOA No.: 18-0509.16
MIAMI•DADE COUNTY Expiration Date: 09/21/21
Approval Date: 06/28/18
Page 7 of 7
}M�IA�MI•DADE
L1♦113i!
DEPARTMENT OF
BOARD AND CODE AD
NOTICE OF
Boral Roofing LL
7575 Irvine Cente
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Prpd}1ct Co• ntrol�ection•.....
•.
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve tlferight to hgte:liis
product or material tested for quality assurance purposes. If this product or material fails to*T)`ert'orm in the 1cctpted ""' •
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately jivoke, modify, or ....
suspend the use of such product or material within their jurisdiction. RER reserves the riglft�p jvboke tjlis% ptance + • •
if it is determined by Miami -Dade County Product Control Section that this product or matoiiaL"Is to meet the ..:..'
requirements of the applicable building code. ""••
This product is approved as described herein, and has been designed to comply with the FI(Vd$ Wilding Cede •
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: BORAL TileSeal
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERNIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This new NOA consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0502.03
MpMI•DADE COUNTY Expiration Date: 08/02/23
UVIMII
Approval Date: 08/02/18
Page 1 of 4
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
MINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
ACCEPTANCE (NOA)
www.miamidade.gov/econoniy
C.
r Drive, Suite 100
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS
PRODUCTS DESCRIPTION:
Product Dimensions
BORAL TileSeal 36" x 36' rolls
36" x 72' rolls
Boral Citadel Plus 36" x 72' rolls
MANUFACTURIGN LOCATION:
1. Brentwood, NH.
2. Houston, TX.
EVIDENCE SUBMITTED:
Test Aaencv
PRl Construction Materials
Technologies, LLC.
Trinity ERD
Test Product
Specification Description
TAS 103 SBS self -adhering asphalt sheet material with a
ASTM D 1970 white glass re -enforced polyester surfacing fabric;
for use as an underlayment in sloped roof
assemblies.
ASTM D1970
Test Identifier
OCF-356-02-04
OCF-356-02-02
OCF-356-02-01
OCF-424-02-04
OCF-424-02-01
OCF-424-02-03
BRLRF-SC 16810.11.17
SBS self -adhering asphalt sheet material with a
poly film -facer; for use as a mid ply uuderlayment
in sloped roof assemblies. • • •
• • ..
......
......
.. .
......
....
. ..
.....
......
. ...
.....
.. ..
.. .
......
Test Name/Repo zt
.... bete
• • • •
ASTMD1623 �••�
47d25/18:�••�:
TAS 103
•OW24/18
ASTM D1970
07/26/18
ASTM D1623
07/25/18
ASTM D1970
07/25/18
TAS 103
07/25/18
ASTM D 1876 11/28/17
NOA No.: 18-0502.03
MIAMI•DADE CC, TY Expiration Date: 08/02/23
"'' ' Approval Date: 08/02/18
Page 2 of 4
0
APPROVED ASSEMBLIES:
Deck Type 1:
Wood, non -insulated
Deck Description:
15/32" or greater plywood or wood plank
System E(1):
Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet:
One or more plies of ASTM D226 Type lI or ASTM D2626 with a minimum 4" head lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps
and two staggered rows 12" o.c. the field of the roll.
Ply Sheet
Apply one layer of Boral Citadel Plus over Base sheet as per current approval.
(Optional):
Membrane:
One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and
minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the meuihrane is
applied. Vertical strapping of the roof with BORAL TileSeal Undwlayment is aooepta•ble. Ake 0 0 0
end laps and laps without black selvage area shall be sealed under lap -ling an �BS:mpdified •,
...... .. . ......
mastic. •
......
00
Note: When used in Tile roof systems BORAL TileSeal Underlayr%ijij s tall be �attpailed ;o • • • •
deck with approved annular ring shank nails and tin caps at a maxin iuu l2" O.C. at tj side . •, •. •
laps. No nails or tin caps shall be exposed. • • • • • • 000000
......
for Adhered Roof Tile using TILE BOND or AH-160, Nfechanfeally ZWS :ed Rode 0':-
Surfacing:
Approved
Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shing:e a rsomblie '. :....
• •
..0000
NOA No.: 18-0502.03
Iff-MIAMI-DADE Expiration Date: 08/02/23
• ' Approval Date: 08/02/18
Page 3 of 4
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable
Building Code.
3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.
4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be
applied over a roofing Base/Anchor sheet underlayment.
5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application.
6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly
to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. • .. •
8. Tiles shall be stored on battens on roof pitches greater than 6:12". *fee • • • • • •
9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Ace�'tance Witt -
fee •
......
BORAL TileSeal underlayment as a component part of an assembly in the Notice of Ac;etdn�e. If BtfRAL •
TileSeal underlayment is not listed, a request may be made to the Authority Having Juris�jVn (AHJJ or •the : • • • •
Miami -Dade County Product Control Department for approval provided that appropriate doaut%entattoi? iS • sees*
provided to detail compatibility of the products, wind uplift resistance, and fire testing remitse: •. :.: ..:..'
10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loos!decicing pan8r . Sweep• • • 0 ; •
the deck thoroughly to remove any dust and debris prior to application. . • • •
. . . ......
11. When applying the membrane in the valley, start at the low point and work to the high point rolling VVA&Inbran;•
from the center outward in both directions. For ridge applications, center the membrane Q roll from the enter .
outward in both directions. •
12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed
in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment
shall be applied over the underlayment, and sealed using an SBS modified mastic.
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below
MIAMI•DADE COUNTY
,...I 1
END OF THIS ACCEPTANCE
NOA No.: 18-0502.03
CAMIMIAMI-DADE COUNTY Expiration Date: 08/02/23
Approval Date: 08/02/18
Page 4 of 4
MIAMI-DADE COUNTY
MIMMi•L'�AM PRODUCT CONTROL SECTION
a ! 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) it-Nvw.nrianudade.2ov/economy
ICP Adhesives and Sealants, Inc.
12505 NW 44" Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the acceptoAwianner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,emodiV, or suspevia the uee..�.
of such product or material within their jurisdiction. RER reserves the right to revokL•thiS acceptatue, if it is • •
determined by Miami -Dade County Product Control Section that this product or material fa1?VV?heet thefegdiremeiitS• •. •
of the applicable building code. • • • • • •
This product is approved as described herein, and has been designed to comply with •tip*•Trrorida Wuilding Cade...
including the High Velocity Hurricane Zone of the Florida Building Code. • • • • • • • • • • • • • •
.. .. .. . ......
DESCRIPTION: ICP Adhesives Polyset® AH-160 • • • • • •
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logd,'cil, state apdofpllowiiig •
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. 0000
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product
Dimensions
Test
Specifications
ICP Adhesives
N/A
TAS 101
Polyset®AH-160
ICP Adhesives Foam
N/A
Dispenser RTF1000
ICP Adhesives ProPacke
N/A
30 & 100
P CTS MANUFACTURED RV OTHERS•
Product Description
Two component polyurethane foam adhesive
. .... ......
Dispensing Equipment • • • • •
• •
• • • • • • • •
Dispensing Equipment
•
• .... •
.. ..
•• . ......
. .
. . ... • • •
RODU
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current N(50P whnch list at: iehment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. .. • •
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Property
Test
Results
Density
ASTM D 1622
1.6 lbs./ft.3
Compressive Strength
ASTM D 1621
18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength
ASTM D 1623
28 PSI Parallel to rise
Water Absorption
ASTM D 2127
0.08 Lbs./Ft2
Moisture Vapor Transmission
ASTM E 96
3.1 Perm / Inch
Dimensional Stability
ASTM D 2126
+0.07% Volume Change @ -40' F., 2 weeks
+6.0% Volume Change @1580F., 100% Humidity, 2
weeks
Closed Cell Content
ASTM D 2856
86%
Note: The physical properties listed
above are presented as
typical average values as determined by
accepted ASTM test methods
and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
MIAMI-DARE COUNTY
Expiration Date: 05/10/22
�Fg...•
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
Test Name/Report
Date
#94-060
TAS 101
04/08/94
257818-IPA
TAS 101
12/16/96
25-7438-3
SSTD 11-93
10/25/95
25-7438-4
25-7438-7
SSTD 11-93
11/02/95
25-7492
SSTD 11-93
12/12/95
NB-589-631
ASTM D 1623
02/01/94
9637-92
ASTM E 108
04/30/93
01-6743-011
ASTM E 108
11/16/94
01-6739-062b[1]
ASTM E 84
O1`l�495
. .
... •
•
Gee*:*
7050.02.96-1
TAS 114
'..'
O-VI4196
.
P36700.04.12
ASTM D 1623
• • • • • •
64 1A/1*42
..... •
P39740.02.12
TAS 101
•••�••
02/2t/12
;�••.;
TAS 123
.•"'.
:'. '.
'
....
. ..
.....
•
528454-2-1
TAS 101
**:Go:
10%2�%
.. ..
.. .
......
528454-9-1
'
528454-10-1
. .
•.
.....
520109-1
TAS 101
i7lAt
.
. .
......
520109-2
••
0
'
520109-3
" "
520109-6
520109-7
520191-1
TAS 101
03/02/99
520109-2-1
LEMTATIONS :
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
MIAMI-DADE COUNTY
�Fjuuq(lynjj�
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset AH-160 may be used with any roof file assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained -between
1.0-1.15 (A): 1.0 (B).
6. ICP Adhesives Polyset AH-160 shall be applied with ICP Adhesives Foam Dispenser RTgL100 or
Adhesives ProPack® 30 & 100 dispensing equipment only. ...:..
7. ICP Adhesives Polyset AH-160 shall not be exposed permanently to sunlight.
•••• • ..
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes iffe; JCP Adhesives
Polyset AH-160 has been dispensed. • • • • • • •
9. ICP Adhesives Polyset AH-160 placement and minimum patty weight shall be in acco;aw with the • •
'Placement Details' herein. Each generic tile profile requires the specific placement noted he{em. ; • • • • •
NOA No.: 17-0322.03
MIAMI•DADE COUNTY Expiration Date: 05/10/22
�F-1WJ31rJq11 Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Minimum Paddy Contact
Minimum Paddy Gram
Tile Profile
Placement Detail
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of file 9-11 sq. inches at
overlap
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
edge) 20-25 sq. inches each
• • • •
bead
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches 1
• ; 034 grams under pan* • •
.....
LABELING: •
...... . ... .....
All approved products listed herein shall be labeled and shall bear the imprint or identifiable Mark?ng of thy'
manufacturer's name or logo and following statement: "Miami -Dade County Product Contro;Approved" or the Miami- • •
. . . . ......
Dade County Product Control Seal as shown below.
PO MI43SOE C • • •
••••
BUILDING PERMIT REQUEREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
MIAMNDADECOUNTY Expiration Date: 05/10/22
"' • ' Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
iti2avirough plastic.umcnt _ Fai+lJy R?r��caslt�3si
y�fi'�Ytxl rl3gUIPQdY !�`-^' t
'?
klir:lgtlaymeric 1�+1n c.r�._"�:X"-...'� �!t
1
waslesscptia-lid
EvoCluiurr--z �' r•• KS' -,i-
Mail through glarlic comer d
iwhm rrgvlri di
i r lwddyOwmathTim
kle�d•rlaytnagrE t. f �,,. � ^`'••,.- f
IQ ln.x
ttmsrss ol>±i±rnal _ t � ••`-,1�^ :• �'•.+�� a' I
>., k.
Ea." closure
Easie {�srrsc - - ' -"-'��ff •�'' -- Fase3a
P14V 6u9hOR.siEav rii••, RaddylBen.•ilsxl«I
tM&ertraCLUrte1
Undel•yic�srL # c + 1 a'•
``ham a`. -•..�4>_ r,�:=—
€a'.CourWin. 2
se --,�.�,�� tjn;.r•,' ,,s`;-- .= ' €aster
•� -�,f ri fa9+- cl+asrrte
,4• t_ r' Imp t119t
MIAMI•DADE COUNTY
�Fnjglrapl
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayinent positioned as shown,
under the strengthening rib closest to the Overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm) — 23 (148.4 cm) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile ."".
1. Starting at the eave cour%e, �ppiy a mi iimum 2" • • • .
(50.8 mm) x 10" (254 niglX j.' (25.4 mrq) foam •
paddy onto the underlaymelatpositioned asshown;"";
under the pan portion of th&W closest to•the • • • • .
• •
Overlock of the tile beingg64t • • • • • • • • • •
•• of •• • ••••••
2. Continue in same mannetTAMe approximately 17
(109.7 cm2) — 23 (148.4 cm2) square ilsah a2kesive "• • •
contact with the undersidegttlT tile. , • • :'''':
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
Overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm') — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
A1` i1 Glfizimgk p a:.iF 4rinepe p%!�k1� 1$i.tjRr7F�7elfj
FJ.^rdBf'�ifntORS y `"i t i�
in-
t A:Z
#. ~�- fy +�v Fes•
.µ 4; ,.• .. `mil .• - it _.
Nail throwlt Plastic —Itt
Ober regniredl
U�ad�ela�tapnt `•� •`"� :��
Pin �-
_ i _ •e- 1 � •_Lk_ i AF x L' _
:� x=
MIAMI•DADE CO�FjUNTY
• •
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
nun) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm'-)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm.) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the file
being set.
•..•
3. Continue in same manner. :nsiptapproximately 10"6 • • •; •
(64.5 cm2) - 12 (77.4 cm2) s4tiareinch 4M$%e •.
contact with the underside ot'ttetile.
.... . .. .....
Medium Profile / Double Pan Ti1n. . ... ..:..'
1. Starting at the eave courseia"15:a minimum 2" (50.8 •
mm) x 10" (254 mm) x 1 " t25.4 fhm) fU-�i.iWdy • • • • • •
onto the underlayment positioVdas shown under thg....;
pan portion of the tile closest to tfie ove locVaf the
tile being set. Insure approximately 17 (Mrl cm2) —
23 (148.4 cm'-) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the file closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
ti%4,em required 1 pd,14 farr.. hTilri
z {i4. _
fit.. ��+`4 • f�. YY
:B:i;teai [Y,p[IaiSn{ J�o. •..ti'` :•'._, •"'.t � X•,:'
ii E-VIIC,ms—��`"— M1.= .' Eric+a
'Wrophc]e
'Eaw LEoswe
1Pn-, Zia. '�+' '' rF L
ter' blipedge
M{AM -DADE COUNTY
. ....a 1
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
inm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. PsWt approxtmiLtely 17"- • • • ; •
(109.7 cm2) - 19 (122.6 cin j %quftre incj AVesive
contact with the underside of tte lile. ' • • • • • • • •
660*6 0000.....
...... . ... .....
.. .. •• • ......
. . . 0000%
•• . . •• • •
. .
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
Mail through plastic cernent Paddy (between tiles)
;when requiredli
Battens optional
t+ Paddy lunderfile)
Singlepaddy r
on top of tile
slepad
im EY ll
Single paddy _ `+
on undedayment 2 n d in.
� r io
f' Fa
��an. asci
•--EaveClosure
Flat/Low Profile Tile
Wall through plasticeement
Sngiepaddy under tile
when required]
Paddy lbetrs*een tiles]
t
Battens
Paddy (under tie]
optional
f
�
' Siogie paddy
��.an top oft le---.
�
z41n,
2s4in.`�.
Singg6e paddy on
undartaymerrt
2in.
Eave Closure
Eave Course
fascia
MLLdlum Pro#ileTile
MIAMI•DADE COUNTY
1. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in (109.7-148.4 cm2) of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam giddy
under the strengthening�rib fQr flat til�,.gr•-trader tag• •
pan portion of the tile, c'losdstxo the u"],prlock for , •
the second course file ta► beiustalled' 1ngule • • • • : •
approximately 8-9 in (5}.4§8.1 cm2) of adhesive •
contact with the undersWC-P the tile; • • • . •
•••• • •• •••••
...... .... .....
.. .. .. . ......
(Instructions continued on 71gjPape) • •
• • • • ••••••
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Nail throughplasGtzz 7t Senrlepaddy under lile
Jwhe!n xe4uUedj
f 'Paddy (between [ifes)
Battens optional Paddy Wndertilel
qr_
r iirigle ddy
on UndtiiiYMErn
dxdin.
3ingie 2 x d in.
paddyone'`,.
topofiiie= •� �� �/'
Save Course f Fasda
Weephole
E.-ve dosure
10 in. 2 in. Drip edge
e
High P.rofiloTile
QMIAMMI-D�ADECO=U
VIM .• M
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4"
(19 nun) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm) - 9 (58.1 cm) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
• •
••••••
•• •
••••••
•
••••••
••••
• ••
•••••
••••••
• •••
•••••
• •
• • •
•• ••
•• •
••••••
•
• •
• •
••••••
•
•
• •
•• •
• ••
• •
• • •
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
1) Place enough adhesive to achieve 65 to 705
in contact with the pan tile.
2) Turn covers upside down. Place adhesive in
to 1 in. from outside edge of cover tile.
Then install the tile. Ensure 20 to
25 sq. in. contact area. °
Underlayment f '
Fascia Board
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Steep pitch applications
(when required)
Remove top portion of the eave course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave fine.
Two Piece Barrel - High Profile Tile
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm') — 70 (451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
sees
3. Turn covers upside dawn exeosing the uddersidese e ..
of the tile. Apply a min:mun! 1" (254mam) x 10" .'
(254 mm) bead of adheshrdirectly on the inner • • • : •
edge of each side of tlfeldddr tile. Leave •;
approximately 3/4" (IP*Ali*�to 1";25.4'mm) '
from the outside edge ot�i� •tile, inwar4 free of .
foam to allow for exp4iaSi94! • • • • ; 00*00
0 0.0 • •
4. Turn cover tile over after foam is a�lied
.... and . , ..:.
.
place onto pan the coarse ..k;sure amimmum of* • • •
20 (129 cm2) -25 (161.5•cm33) squ4e jne13 •
contact area on each side of the covd i'CM to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF TIUS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11