Loading...
RF-19-57Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 01/11/2019 Location Address Parcel Number 295 GRAND CONC, Miami Shores, FL 33138 1132060133600 Contacts Permit NO.: RF-01-19-57 Permit Type: Roof Work Classification: Repair Roof Permit Status: Approved Expiration: 07/10/2019 NEIL HART Owner OBENOUR ROOFING SHEET METAL & Contractor 295 GRAND CONCOURSE, MIAMI SHORES, FL 331382852 SUPPLY CO. INC Other:3059624547 JAMES OBENOUR 9822 NE 2, MIAMI SHORES, FL 33138 Business: 3057572612 OBENOURROOFING@AOL.COM Silverlight Permit Solutions Agent Arlenis Silvera 10050 Ne 2 Ave, miami shores, FL 33138 Business: 3051234567 silvera@mailinator.com Description: INSTALL LEAD FLASHING FOR NEW PLUMBING Valuation: $ 500.00 Ins section Requests: PIPE & RELLEY BORAL FLAT TILE PROVIDED BY OWNER 1305-762-4949 BORAL 13" FLAT BLEND COLOR OWNER PROVIDES Total Sq Feet: 1.00 Fees Amount Application Fee - Other $50.00 CCF $0.60 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $0.20 Roofing Fee $50.00 Scanning Fee $9.00 Technology Fee $6.25 Total: $122.30 Building Department Copy Payments Date Paid Amt Paid Total Fees $122.30 Check # 9543 01/11/2019 $122.30 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws t@gulatiG&onstruction and zoning. Futhermore, I authorize the above named contractor to do the work stated. / Applicant / Contractor / Agent Date January 11, 2019 Page 2 of 2 r , BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ROOFING ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: 295 GRAND CONCOURSE i � CEI D J' N 10 0 [[�� FBC 20 Master Permit No.?*—'01—'��J! % Sub Permit No. ❑ REVISION ❑ EXTENSION [:]RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): NEIL HART Address: 295 GRAND CONCOURSE City: MIAMI SHORES State: FL hone#: 3059629547 33138 Tenant/Lessee Name: Phone#: Email: ECSHART@AOL.COM CONTRACTOR: Company Name: Address: 1 a z 2, � � r City: Qualifier Name: State Certification or Registration #: _ DESIGNER: Architect/Engineer: Address: Value of Work for this Permit: $ Type of Work: ❑ Addition Description of Work: ne#: _Zip: _3_�) 3b ne#: -_ys Certificate of Competency #: Square/Linear ❑ Alteration ❑ New Specify color o color thru tile: {! 00 Submittal Fee $ Permit Fee $ lop. Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) hone#: State: Zip: of Work: /Replace ❑ Demolition CCF $ CO/CC $ r ' " V "" DBPR $ Notary $ Double FeQ $ 2 Bond $ 1 �C_ — 3M TOTAL FEE NOW DUE $ j Z2 30 . .f ..ti V` Bonding Company's Name (if applicable) Bonding Company's Address N/A City N/A State Mortgage Lender's Name (if applicable) Mortgage Lender's Address N/A City N/A State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In thy-yabsence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. �� -17 Signature OWNER or AGENT The foregoing instrument was acknowledged before me this 1 day of jQ.N ax Y y , 20 l' by 1�11 P_,` / )�C[ Y who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Print: Seal: l� CONTRACTOR TVforegoing instrument was acknowledged before me this day of , 20 by � O1t,/' [�{/, who is personally known to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: ( ilu1 P A . I' (Atf�( � CATHERINE A. DUFFIN NotaryPublic- StateofFlorida Commission p GG 104296 Lill yy, My Comm. Expires May 14, 2021 ********************************* ********* APPROVED BY &Jlt5/L�_ Plans Examiner Zoning as _4,ctefl top up 1PpY PU �I� `gyp; State of Florida -Notary Public _� •_ Commission # GG 143708 ,yoFF�R My commission Expires �,I�r+�� September 17. 2021 Structural Review Clerk (Revised02/24/2014) ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 HIGH -VELOCITY HURRICANE ZONES —UNIFORM PERMIT APPLICATION Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFINC+PEifMIT • APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTtlb BtLOVIr...:. Roof System Required Sections of the Permit Application Form Attachments Ae4imd See List Belevw • Low Slope Application A,B,C 1,2,3,4,5,6,y* Prescriptive BUR-RAS 150 A,B,C 4,5,6,7. �.. Asphaltic Shingles A,B,D 1,2,4,5,$, :0: Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,0,! • Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation 468 FLORIDA BUILDING CODE - BUILDING, 6th EDITION (2017) MIMI®Du4DE � MiAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 • • 0 . . . ......... Irvine, CA 92618 •..• .' ...... . ...... SCOPE: • This NOA is being issued under the applicable rules and regulations governing the use of coiis"thiation niatezi ds. The documentation submitted has been reviewed and accepted by Miami -Dade County PER - Product Control Section to * 0 • • • ...... .... A %. used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdic$ilq&CAHJ)' .... • ...... This NOA shall not be valid after the expiration date stated below. The Miami -Dade Counti Product ControlSection. •.: • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this :0 0 0 • product or material tested for quality assurance purposes. If this product or material fails to pt4ortn in tae gt%pted • ' manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, moallfy, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.16-0711.05 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-CateEory: Roofing Tiles Material: Concrete Deck Type: Wood SCOPE This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete •ljtppj*Tile, .4,% • • • manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of'Ade;tance. For. locations .' where the pressure requirements, as determined by applicable Building Code, do not•exemd the design pressa"•%• values obtained by calculations in compliance with RAS 127 using the values listetl•ilf the installation sectip. � �; herein. The attachment calculations shall be done as a moment based system. ." :...: • ' .... • • • • • • 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Saxony 900-Slate Saxony 900 Split Shake Saxony 900-Shake Trim Pieces Length = 17" Width = 13" thickness = 1-5/32" Length = 17" Width = 13" thickness = 1-9/32" Length = 17" Width = 13" thickness = 1-9/32" Length: varies Width: varies varying thickness 00*000 .. .. .... ...... Test PrQdutt Specifications Description TAS 112 Flat profile, interlocking, hi*gh-p;essurd exfrtided ' concrete roof tile with two nail holes. ForIfirect deck, batten, mortar set or adhesive set applications. TAS 112 Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. Top surface produced with 4 different configurations: 1. Complete tile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush TAS 112 Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. TAS-112 Accessory trim, boosted Barcelona, concrete roof pieces for use at hips, ridges and rakes. NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 2 of 9 2.1 MANUFACTURING LOCATION 2.1.1 Lake Wales, FL 2.2 EVIDENCE SUBMITTED: Test Agencv Test Identifier Test Name/Report Date The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) • • * • • *se** The Center for Applied 94-060A Static Uplift Testing • ; IYlarcS, 1994*'*::* Engineering, Inc. TAS 101 (Adhesive Set) ...... """ ' . ...... The Center for Applied 25-7183-6 Static Uplift Testing TAS 10a.:.. Feb. 1995 • Engineering, Inc. (2 Quik-Drive Screws, Direct Doc"• • ; • . •; . • • The Center for Applied 25-7183-5 Static Uplift Testing TAS 102"' 'Feb. 1995 Engineering, Inc. . ... (2 Quik-Drive Screws, Battens : .... ..... The Center for Applied 25-7214-1 00 Static Uplift Testing TAS 102 Marsh, 1995 • • • • Engineering, Inc. • (1 Quik-Drive Screw, Direct Dgckl ....:. lrch,'1995 The Center for Applied 25-7214-5 Static Uplift Testing TAS 102 lk • • Engineering, Inc. (1 Quik-Drive Screw, Battens] • • • • • The Center for Applied Project No. 307025 Wind Driven Rain Otf.'1994 Engineering, Inc. Test #MDC-77 TAS 100 Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II & III TAS 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Atlanta Testing & R1.894/R2.894/R3.894 Physical Properties Aug. 1994 Engineering, Inc. TAS 112 Celotex Corporation 520109-1 Static Uplift Testing Dec. 1998 Testing Service 520111-4 TAS 101 Celotex Corporation 520191-1 Static Uplift Testing March 1999 Testing Service TAS 101 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584/25-7804b-8/25-7804-4 & 5 December 1996 25-7848-6 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations Restoring Moments Due to Gravity 09/01/16 American Test Lab of RT0617.04-16 TAS 112 06/29/16 South Florida NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 3 of 9 PRI Construction Material COPO-002-02-12 TAS 101 10/12/2016 COPO-002-02-06 TAS 101 10/12/2016 COPO-002-02-05 TAS 101 10/12/2016 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. •••• 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to•Qerforrrrq-am1erly tear •; • in accordance with TAS 112, appendix `A'. Such testing shall be submittttl td the hwapg Code ..... Compliance Office for review. : • • ...... . .• 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Ap••p�i0 0t�ons �tand§rds list-tl• • • section 4.1 herein. ***so* . • • • • • ..... 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to.thc roof slopaxxl :ss statto • • otherwise by the underlayment material manufacturers published literature. • • • • 0000 • • •. • • 3.6 This acceptance is for wood deck applications. Minimum deck requirements Wall U•e in compliance with 0 o • the applicable Building Code. • • • • • • .. . . .. . . . . . 0000 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-1 (ft) Width-w (ft) Saxony 900 Slate, Shake & Split Shake 10.9 1.417 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Tile X (ft3) X (ft3) Profile Batten Application Direct Deck Application Saxony 900 0.291 0.315 Slate, Shake & Split Shake Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 211:12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Saxony 900 Slate, Shake & Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Split Shake 7.70 7.62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95 NOA No.: 18-0509.17 MIAMI•DADE M Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Saxony 900 2-10d Ring Shank Nails 30.9 38.1 17.2 Slate, Shake & Split 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 Shake 2-10d Smooth or Screw Shank Nails 14.0 18.8 "'. 7.4 1 .#8 Screw 30.8 : 3( 18.2 2 .#8 Screws 51.7 1.7 • • • •24.4 1-10d Smooth or Screw Shank Nail (Field 24.3 24. 24.2 Clip) • 1-10d Smooth or Screw Shank Nail (Eave 19.0 •; �9�Q• 000022.1 Clip) 2-10d Smooth or Screw Shank Nails (Field 35.5 ��• •00'34.8 Clip)� • 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 ; 3-r9 0 . 32.2 "" Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) '.:..' for Two Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Saxony 900 Slate, Shake & Split Shake Adhesive' 31.3 2 a 3 594 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBond" one -component foam minimum weight per paddy 13.9 grams. 3. ICP Adhesives Polyset® AH-160 two -component foam, minimum weight per paddy 8 grams. 4. DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake ICP Adhesives Polyset® AH-160 Two -component foam DAP Products Touch N' Seal Storm Bond 2 two -component foam 118.9 3 40.4 4 935 456 3 Large paddy placement of 45 grams of Polyset® AH-160. 4 Medium paddy placement of 24 grams of Polyset(R AH-160. 5 Large paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 45 grams. 6 Medium paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 24 grams. NOA No.: 18-0509.17 Iq MIAMI•DAD, COUNTY Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 5 of 9 :. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Tile Minimum Attachment Profile Application Resistance Saxony 900 Slate, Shake & Split Shake Mortar Seth 43.96 .... . .... 7 Tile-Tite Roof Tile Mortar .. . 5. LABELING • ...... 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as .detaile8`:'•. ...... ........ below, or following statement: "Miami -Dade County Product Control Approved" • . . . . ...... LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS NOA No.: 18-0509.17 QMLAMMMMADE COUNTY Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 6 of 9 NAIL HOLES 1 UNDERLOCK I SAXONY 900 - SLATE .... ...... 5/32" (Slats' o • • • • 0*060 COVERLOGIt• • •see NOA No.: 18-0509.17 MIAMMADE COUNTY Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 7 of 9 NAIL HOLES PROFILE DRAWINGS dP Note: Available Top Surface Finishes 5. Complete tile brushed 6. Right half brushed (shown in drawing) 7. Left half brushed 8. No brush SAXONY 900 - SPLIT SHAKE APPROVED NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 8 of 9 NAIL HOLES 0 PROFILE DRAWINGS SAXONY 900- SHAKE END OF THIS ACCEPTANCE NOA No.: 18-0509.17 MIAMMAD, COUNTY Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 9 of 9 OZ cM!�IIA��M�I MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: 0• This NOA is being issued under the applicable rules and regulations governing the use of Lops't;Iction Jn 0 0 * als. The • documentation submitted has been reviewed and accepted by Miami -Dade County RER-Prodxat.Contrai Set tibn to b� • ; used in Miami Dade County and other areas where allowed by the Authority Having JurisdictRi "O(i4HJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County�rptluct Q0dMd6? SectiQiV• • • • (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve tho fight to hay e4is prodt4; • 0 • or material tested for quality assurance purposes. If this product or material fails to perform in the accepte0smAner, the.... t manufacturer will incur the expense of such testing and the AHJ may immediately revoke,:84q, or suspend the use • • of such product or material within their jurisdiction. RER reserves the right to revoke this' accepWj4. if it•iS••:• determined by Miami -Dade County Product Control Section that this product or material fails t e meet the re c�uiremedu,.. of the applicable building code. ..• .. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. 0 , Ef HE � =I NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset' AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with RoofX19. - Application Standard RAS 127. For use with approved flat, low, and high profile roof tile slsteUt.using ICP - Adhesives Polyset AH-160. '• ;,�.; PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications ICP Adhesives N/A TAS 101 Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: • ... • • •....• Product'09?criptioh • • • • • .. .. .... ...... Two component pobri Vbane foans adhesive • . . . . ...... Dispensing Equipment. • • • • • • • Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 ruvr�i�uNn Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTMD 1623 .'. 07/61i94 "'•:• Polymers Division • • • • • • ...... . ....% Ramtech Laboratories, Inc. 9637-92 ASTM E 108 .... 0.4/30493 ; • • • •; .000 . •.•.• Southwest Research Institute 01-6743-01 I ASTM E 108 • • • • 1 M'd6f94 ' ..... 01-6739-062b[ 1 ] ASTM E 84 • • • • 0 W1645 .... • Trinity Engineering 7050.02.96-1 TAS 114 43-4 % P36700.04.12 ASTM D 1623 14/1&12 • • • • P39740.02.12 TAS 101 0;/r1ji2 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset' AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset' AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application • • • • • • Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and lai&kance.Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensedb*)I* 11�p Adhesives and ..... Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators W the authority havin;• ...... • • • jurisdiction. •••• • ••••• 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is ?eZ W?Ul bef%6 laDVIicatioti• • • • • of any adhesive. The mix ratio between the "A" component and the "B" component s11a71 %e maintaine$•betweeh 1.0-1.15 (A): 1.0 (B). • • • • • • • . . . . *00000 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispense] R'LF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. • • • • • 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset AH-160 has been dispensed. 9. ICP Adhesives Polyset AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches High Profile #2 17-19 sq. inches • �Q • Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at. .;.1.2 grams ppr paddy head of tile 9-11 sq. inches at ... ;" overlap ••• ... Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal. •. • 17 gra41%,p:?bead • • • edge) 20-25 sq. inches each . .... bead ... Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 4 .' t4 grams under pari " LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 1 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 IItaU t}r=h prattle cWhont Paddy moneathiW) frMratrroqutred) II�� trwtl►fiJyT•IM • • 1 101 alttgM oDtianai ° N.. E*vo Comm* = foula Ew. do+ur• Nail through plastic cern,"v (when readred) vnd•rt•ynswrt tomdo ^� tatterrs optional AV lei ^. 2 LWO Closure EawC•urse `— Fascia li•il through pl.+tic twhen req "'Mo ►d dY (R•nwlh Tii.! Und.rl.yrrwnt ` ..rr iltln.a 2 In. wide Battens e optsenal • f ► Ear" Geurse Fascia ` Weephole Coln �9tn. Eawdostwe \Drip y edge Flat/Low Profile Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approxiVtely 17 (109.7 cm) — 23 (148.4rcm:)'square iflCl? 8dhesivV • • ; • contact with the underside of the tile:.*.:* • ••ee% • • •..o•. Medium Profile / Double PUIC IIe •, 1. Starting at the eave cour %e,, apply a minimum 2" :....: (50.8 mm) x 10" (254 mm) x 1" (25 4.rjipt foam • paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the Overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 � Plastic ►addyMrnaath"Wj to ��' UIwde,t"mont 1 i • `. Oatwti e0tla+ai • EAw Course i I01n. Fasda Nail through planic cement hrhen rearriredl Paddy4Mm a•thTile) Ursd«I�ym►nt sw ti 2 in. 1 t tternoptional E•w clotwro Eavacoun• f fasdu MUUNFDADE COUNTY W-1122"Kill Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1 " (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. • . . .... ...... 2. At the second course, apply& qmic imumV M.8mm) a .. a a x 7" (177.8 mm) x 1" (25.4•mt;�am paddy onto the underlayment positioned as,Mdit undo j$g; • • strengthening rib closest to the overlockof the tile • •; • •. being set. ...... .... ..... .. .. .... ...... 3. Continue in same manner. lnsuYeipprozimatply 10"• • • • ; • (64.5 cm2) - 12 (77.4 cm2) iqu are inch adhe%?e a • contact with the underside of the tile. • • ...... Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) NO dw*uyh pbstk ce OA*n ►o"lmo PA414 (MrnwMbrile$ A �c 2 In. amens eiptlawal 1 Frye Course t<ascia loin. 2 M. re ,Fa(%$we UP edge High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square mch jadhgive conla� t with the .... • • underside of the tile. • ...... . ...... 2. At the second course, apply vAirtimum 2" E50.8mmj x 7" (177.8 mm) x 1 " (25.4. "irly foam aagdy gnto tlie• underlayment positioned as Sliddlm under the pan • •; • • • portion of the tile closest to W overlock olAhe tile ""• .. .. .... ...... being set. • . . . . ...... 3. Continue in same manner. Insure approklth dly 17" (109.7 cm2) - 19 (122.6 cmhi squitre inch adhesive contact with the underside of the tile. • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Nail tArough plastic cement (wince required) Paddy (between tie:) "nensoptional ' • (under tile) 9.* paddy an top at tRe siaglepaddY 4n `r 2 Y 4 in. 101nr 3 zin �•\ 6aYeC9ostte Flat&ow ProfileTilo Man dwemffi plastic cement Single paddy under Me (aim required) PA ddy (between Wes) Battens optional paddy (under tie) Skhoe pad� - ontopotttie ` 4X4in. n sic . punderla�on 0 h.~` " 2 in. Eare Closure EaveGourse fasda Medium PmflleTlle 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expgpOcOgdhesive from blocking the weep hoV.Insure' • • • • • • •; • approximately 17-23 in' OT)9.1-148.4 cmof adhesive contact with ft.jr�e* side of the tile 2. Apply a 4" (101.6 mm) x•4'1+41.6 qm).x V (25A:..' mm) foam paddy onto the uu)derlaymerAt vst below • •.. the second course line 0% ttMcd foam 11addy • under the strengthening rib for flat tit*.orunder th>s'... pan portion of the tile, AoseJ to the underlock fo'r... a: the second course tile to be installed! jrjj re approximately 8-9 in (51.6-58.1 cm 2) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL ## 3 (CONTINUED) Marl through piast)c Sin je paddy under the (when required) Daadjlhetween Hles) Battens optional Paddy (under tile) siolle �an 4 x a in. S ddddyon t2 x t in toopofWe Ewe course fasda weephole loin. in Eave dosure Drip edge High ProtilaTile 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/a°' (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm') - 11 (71cm2) square inch adbgsive contact with the undersile ofthe the atlka overlap..... and 7 (45.2 cm2) - 9 (58.1•Cm27squair�ipjj . • adhesive contact with tht%felside df the tile at • • • • • • the head of the tile. ConWnuein same manner. :see*: •••• .... . ..... so *000 00 • . . ...... NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications in contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq.In. contact area, Underlayment Eaveclosure (motar shown) Fascia Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive h4?9thgnce to • • •••• •••••• cure. • • •••••••• 2. Continue in same mat:,;: �•••nging• twgpan • ...... courses up toward the yWg& Insure. • approximately 65 (414.4cimr — 70:C45' 9 cm2)• •... square inch adhesive donaetwith V"an jerside, • • • • of the pan tile. " " •••• •••••• 3. Turn covers upside down c posinj*a-;xdersiJe � % of the tile. Apply a ni ftVIUr: 1" (2, 5 Ajpm) x I $� • • • (254 mm) bead of adhesive directly.&) fe inner • edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 em2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11