RF-18-2323Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
(Permit
Issue Date: 8/30/2018
Permit No. RF-8-18-2323
Permit Type: Roof
Work Classification: Tile
Permit Status: APPROVED
Expiration: 02/26/2019
Project Address Parcel Number Applicant
1069 NE 91 Terrace 1132050010080
Miami Shores, FL Block: Lot: JULIET SUZMAN
I
Owner Information Address Phone Cell
JULIET SUZMAN 1069 NE 91 TERR
MIAMI SHORES FL 33138-3401
��11�1 ���IIIflIIfliA111i1Y�!
Contractor(s) Phone Cell Phone
ALPERO GENERAL CONTRACTOR (786)357-7414
Type of Work: Re Roof
Additional Info: NEW TILE ROOF ADDITION
Classification: Residential
Scanning: 3
Fees Due
Amount
CCF
$3.00
DBPR Fee
$3.75
DCA Fee
$2.50
Education Surcharge
$1.00
Permit Fee - New Roof
$250.00
Scanning Fee
$9.00
Technology Fee
$4.00
Total:
$273.25
In consideration of the
pertaining thereto and in
accepting this;j1permit I
required for ELECTRICA
OWNERS AFFIDAVIT,./
construction and zonild
Valuation: $ 4,100.00
Total Sq Feet: 650
Avauaoie inspections:
Inspection Type:
Up Lift Report
Tin Cap
Final Roof
Tile In Progress
Review Roof
Renailing Affidavit
Cap Sheet
Pay Date Pay Type Amt Paid Amt Due
Invoice # RF-8-18-68733
08/30/2018 Credit Card $ 273.25 $ 0.00
o me of this permit agree to perform the work covered hereunder in compliance with all ordinances and regulations
ormity with the I s, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
INZnsibility,,fvrall work done by either myself, my agent, servants, or employes. I understand that separate permits are
ING�-MgGHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
ill the fo oing information is accurate and that all work will be done in compliance with all applicable laws regulating
I au#lbrile the above -named contractor to do the work stated.
August 30. 2018
u nonzed Slgnatur . ?ar / Applicant / Contractor / Agent
Bui ing Department Copy
August 30, 2018
Miami Shores Village RECEIV50
Building Department AUG 3 0 2018
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
FI3 201':4-
BUILDING Master Permit No. 1 -� — / J - 7
PERMIT APPLICATION Sub Permit No. �232�
❑ BUILDING ❑ ELECTRIC ) ROOFING ❑ REVISION ❑ EXTENSION [:]RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
/' n CONTRACTOR DRAWINGS
JOB ADDRESS: f D 60 Ni ! I �£IZIZ
City: Miami Shores County: Miami Dade zip: 33130
Folio/Parcel#: I — 3zc,5- Oa 1-00M Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): JvLe4 Jf/mapy Phone#:
Address: ��(9-1 rrIV
City:_ State: L - Zip:'3-3/-3e
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name:
Address:
•
one#:
City: t P— f State: E: zip: 33/76
Qualifier Name: 1 Phone#:C')V(, 35`/ 7
State Certification or Registration #: V / Certificate of Competency #: °
DESIGNER: Architect/Engineer: NIA - Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ �I% 00 Square/Linear Footage of Work: 4�-S0
Type of Work: ❑ Addition ❑ Alteration New ❑ Repair/Replace ❑ Demolition
/ ,{ k•.
Description of Work: A/ /
.r
Specify color of color thru tile:
Submittal Fee $ Permit Fee $ CCF $ CO/CC $
Scanning Fee $ Radon Fee $ DBPR $ Notary $
Technology Fee $ Training/Education Fee $ Double Fee $
Structural Reviews $ Bond $
TOTAL FEE NOW DUE $
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning. �, , _, , • s�
"WARNING•TO'.OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an esfimated,value"ex eedu;g $2500, the applicant must
promise in good faith that, a copy of the notice of commencement and construction lien law brophure'will be delivered. to the person
whose property is subject to attachment. Also, a certified co ' ' '`- t
p p y �py of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not bpapproved and a reinsp_&cf7-o_n_7e—eWQ be charged.
OWNER or AGENT
The fokegoing instrum nt was acknowledged before me this
��day of VC1 f/S-r 20 /p, by
Jih%nJ' Au% w who personally known o
me or who has produced
Sign
The foregoing instrumen/was acknowledged before me this
�nn5 ,, da of Aodu J 20 by
(�i2d�o 1 i� 5 who is personally known to
as me or who has produced
identification and who did take an oath. identification and who did take an oath.
as
NOTARY PUBLIC:
NOTARY
PUBLIC:
Sign:
pMEZ a
Sign:
Print:
a Z
P 01�021
Print:
%
Seal:
.�� MYComm.FxN �a1N�a'Y�"�'
+
�
DAjs
�y
•••'IF F�,.•
/�,��� y�y��p��i
Cmvnbft III GG2M
OF
,�,
�
�EF
ftft ftuA" ftwy
################################ ### ### #################################################################
APPROVED BY
Plans Examiner
Zoning
Structural Review Clerk
(Revised02/24/2014)
s�� OFFICE OF THE PROPERTY APPRAISER
Summary Report
Property Information
Folio: 11-3205-001-0080
1069NE91 TER
Property Address:
Miami Shores, FL 33138-3401
Owner MICHAEL SUMAN &W JULIET
Mailing Address 1069 NE 91 TERR
MIAMI SHORES, FL 33138-3401
PA Primary Zone
1100 SGL FAMILY - 2301-2500 SQ
0101 RESIDENTAL- SINGLE FAMILY
Primary Land Use
1 UNfr
Beds / Baths / Half
4/2/0
Floors
2
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
2,605 Sq.Ft
Lot Size
9,375 Sq.Ft
11925
Year Built
Assessment Information
Year
Land Value
Building Value
2018
$337,500
$196,375
2017
$337,500
$181,308
2016
$314,250
$181,308
XF Value
Market Value
Assessed Value
$0:
$532,875i
$276,503i
$0
$518,808
$270,816
$0
$495,558
$265,246
Benefits Information
Benefit Type 20181 2017 2016
Save Our Homes !Assessment
Cap Reduction $256.3-7722 j $247,992 $230,312
Homestead Exemption $25,0001 $25,000 $25,000
.. - _.
Second Homestead Exenption $25,000 $25,000 $25,000
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
Short Legal Description
WATERSEDGE PB 9-141
LOT 9 & W1/2 LOT 10 BLK 1
LOT SIZE 75.000 X 125
OR 18317-2696 1098 1
Generated On: 8/15/2018
Taxable Value Information
2018
20171
2016
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$226,503
$220,816
$215,246
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$251,503
$245,816
$240,246
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value 1
$226,503
$220,816
$215,246
Regional
Exemption Value
$50,000
$50,000
$50,000
Taxable Value 1
$226,5031
$220,816
$215,246
Sales Information
Previous Sale Rice OR Book -Page Qualification Description
10/01/1998 1 $201,000 18317-2696 Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property
Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/discialmer.asp
Version
Alnero General Contractor Inc.
8900 SW 126 Ter Miami FI 33176
Cell: (305)303-58164 Lic #CCC1328188
ALL TYPES OF NEW ROOFS • RE -ROOF • REPAIRS' ROOF MAINTENANCE
• WATERPROOFING • BUILT-UP ROOFS "CON ERCIAL' RESIDENTIAL
Customer Name: Distintive Homes
Job Address: 1069 NE 91 Ter Miami Shores Fl
Sale Representative: Valerio Flores (305)244-4590
We hereby submit the estimate/contract for a new roof in the following manner:
• Tile Roof
• Install new paper #30 with nails and tincaps.
• Install new metals 3"x3" and valleys where are required.
• Install new paper self adhering TU Plus.
• Install new clay tile with foam.
• The Contractor is responsible for permit and inspections required.
Premises shall be left cleaning of roof debris. Owner must provide access to work, water
and electricity. We propose hereby to furnish material and labor complete in accordance
with the above specifications.
The total job cost: ($4,100.00)
Payments Schedule:
Sign application.($1,000)
50% star job
25% at the first inspection
25% final inspection.
TERMS AND CONDITIONS OF CONTRACT
1. All workmanship and material shall be guaranteed against defects for a period of 10 years from the
completion date of the work. This guarantee does not apply in the even of fire, termites, windstorm or
damage caused by acts of God. This guarantee does not apply to leakage caused by footwear: improper
building or roof deck construction: improper roof or building design: nor puncture or penetration of the
roof integrity for the installation of air conditioning units, fixture, signs, Hatchways, pipes or other
structures supports or braces, unless installed as a part of this contract by Alpero General Contractor.
2. No guarantees shall apply until the contract is paid in full.
3. Any legal expenses incurred by Alpero General Contractor for collection of the contract price or any
installments due there under shall be paid by owner.
4. This contract only cover the work specifically set forth herein. The contract does not cover any
additional work found necessary after commencement of the job. Owner agrees to execute any addendums
to this contract necessary to cover the additional work.
5. Alpero General Contractor shall be relieved of its obligation to timely perform this contract in the event
of material shortages, labor disputes or strikes beyond the control of Alpero General Contractor.
6. This warrantee is transferable to a new owner.
7. If upon re a o existing roof a defect is found in the structure or decking by an inspector or others,
Alpero eral Co actor is not responsible for these types of hidden conditions. The owner will occur all
cost sociated th its r r or a ntracting of general contractor for the structural repairs.
above prices ications and con itions are satisfactory and are hereby accepted by:
r7/1
Date
Sale Representat' a Date
a
t
Cr
E
a
2
1
�
■■■■■■■■■■■■■■■■■■■■■■■■■
I�ll�■�■■■1�■■\\l.���,l./■■■ram■■
■■
IM,
mum
MEEMMEN
■���■■■■■■��■�M■■W:
■■■■■■■
■WEINI■■
IPANIM■■■■■■■■■■■■■■■
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
_t
Florida Building Code 6th Edition (2017) RECEIVED
1
High -Velocity Hurricane Zone Uniform Permit Application Form 1
AUG 302018
Section A (General Information) 1
Process No. 1
Contractor's Name
Job Address
1
ROOF CATEGORY 1
❑ Low Slope ❑ Mechanically Fastened Tile Mortar/Adhesive Set Tiles i
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes �. 1
❑ Prescriptive BUR-RAS 150 •. • .. .
ROOF TYPE` ' •' •' ' • ' "' J''
19 .••..•
New roof ❑ Repair ❑ Maintenance Reroofing ��,p Reco;enng�
ROOF SYSTEM INFORMATION 0 1
.... .• .. / ... .
Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF)� / 4 6: 6 0: TOO .
•• •• •••• ..••I..
Section B (Roof Plan) so ...0.0
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and bygifloV drains. Include dimes• •I. •
sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. .".'. ' I '
•
1
1
1
1
1
1
1
1
1
1
1
1
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof
Roof System Manufacturer: ""a
Notice of Acceptance Number: i9-
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
P1: 3Gh l P1: (0 P1:
1
Deck Type: t 8rr •••••� 1
Type Underlayment: 3&o f�••... .....1.
Roof Slope: • E
-—' 2 r
Insulation: kl •
000*0* 9000 0*000
Fire Barrier: A/ of-**- • • •' • • • • •t
• • '1
Ridge Vent' ation? Fastener Type & Spacing: ,l -e 151��',;,�
. 009
Adhesive Type: a PSl dQ, 1
Type Cap Sheet:
1
Mean Roof Height: I Roof Covering:
1
Type & Size Drip " n 1
Edge: 1
I
1
1
1
1
1
1
1
1.
1
I
1
1
1
1
1
1
1
1
1
1
1
i
1
1
i
1
1
1
1
1
1
1
1
1
1
1
1
i
1
1
1
1
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from M,. If the M, values
are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable.
Method 1 "Moment Based Tile Calculations Per RAS 127"
(P131. f x %0 &L Mg: = Mr,!;.Z Product Approval M,
(P� x> 0 =a ��) - Mg,�� = Mrz 1 .� Product Approval M,� Q/) J
(Pik xaQ: -a,2 - Mg- = Mr, Product Approval M, S d� �4 �o� ite ii✓e,
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval M,
M, required Moment Resistance* ; .0.
Mean Roof Height
Roof Slope
15'
20'
25'
30'
....4Q
2:12
34.4
36.5
38.2
39.7
4 .
3:12
32.2
34.4
36.0
37.4
• • • •3r.8
4:12
30.4
32.2
33.8
35.1
... X93
5:12
28.4
30.1
31.6
32.8
• • 434.9
6:12
26.4
28.0
29.4
30.5
: * 0 =4
7:12
24.4
25.9
27.1
28.2
30.0
*Must be used in conjunction with a list of moment based tile systems endorsed by the Broward Codnty Board of.R Ala s and
Appeals. • • •
For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the the attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 127"
(P1: x L = x w: = ) - W: x cos 6 = Fr, Product Approval F'
(P2: x L = x w: = ) - W: x cos 6 _ = F, Product Approval F
(P3: x L = x w: = ) - W: x cos 6 = F„ Product Approval F
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis pre-
pared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
6
Job Site
Aerodynamic Multiplier
Product Approval
Restoring Moment due to Gravity
Mg
Product Approval
Attachment Resistance
M,
Product Approval
Required Moment Resistance
Mo
Calculated
Minimum Attachment Resistance
F
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
All calculations must be submitted to the building official at the time of permit
application.
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2nd Ave
Miami Shores, FI 33138 ,
•s••
o
• • ••o ••••••
.. •
..Date: Aube ....
*soot
•t••••
••t••t
•o . •• • . t
Dear ildi Official: ...•
I certify that I am not required to retrofit the roof to wall connections of my
b ing because:
The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00, Please attach proof of ad
Re: Owner's Name:
•••• . •
• • • • •
•
Property Address: 10 t'r 6 N _ 91 7C t'L • • • • • • •
Roofing Permit Number: so :"•••
valorem taxation.
❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
n of the South Florida Building Code (1994 SFBC)
JV 111J—su M a. N
Print Name
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that helLfW is the owner for the above property mentioned.
Sworn to and subscribed before me this r -fL- day-oL. "c r sr
ELZIRISGOte��a
t�'° �� P Notary Public- � (,r"i071342
Notary Public, Sate of Florida at Large = • commtss resfeb9,2021
• When the just valuation of the structure for purpose]iMitTon is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994
SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revised on 5121 009
MIAM�
i)
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.¢ov/economv
Ceramica Verea
Lanza S/N 15685
Mesia (Coruna) Spain
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to ha4y: • ... • • •
product or material tested for quality assurance purposes. If this product or material fails to perfornI in the accepted • •
manner, the manufacturer will incur the expense of such testing and the AHJ may immediate47#woke, modiky,Or ....;,
suspend the use of such product or material within their jurisdiction. RER reserves the right to teeeke this acceptance • • • •
if it is determined by Miami -Dade County Product Control Section that this product or materlIMM1s to meet lie. •
.... .....
requirements of the applicable building code. .. ..
This product is approved as described herein, and has been designed to comply with the Flor*ica00 M;ldingC*ct •
including the High Velocity Hurricane Zone of the Florida Building Code. .. • • • • •
. . . . ......
DESCRIPTION: Verea "Spanish S" Grade 1 • • • • • •
. V909:
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state andfioilowing
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 16-1012.09 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0119.02
MIAMI•DADE COUNTY Expiration Date: 03/13/23
• ' Approval Date: 03/22/18
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Clay
1. SCOPE
This approves a roofing system using Verea "Spanish S" Grade 1 manufactured by Ceramica Verea, S.A. in
La Coruna, Spain and is distributed by Ceramica Verea, USA Corp., as described in Section 2 of this Notice of
Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does
not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values
listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Verea "Spanish S" Grade 1
Trim Pieces
Verea Hurricane Clip
Dimensions
L = 19.5"
W = 10.85"
H = 2.8"
Length: varies
Width: varies
varying thickness
2.95" x 0.47" x 0.09" diam.
2.1 MANUFACTURING LOCATION
2.1.1. Mesia (La Coruna) Espana
Test
Product
Specifications
Description...
ASTM C1167
High profile clay.rooftil8.'ror direct
Type I
Grade 1
deck, adhesive set applie.. .alione. �.
..... ..... .
ASTM C 1167
0000.0
Accessorygitd,•cjay ropf pieces for •
use at hips, TAIMs, ridges"and•,?alley • •; • • •
... ..
terminations..�.narbufacture.dbc each ...
.. .. .... ......
tile profile,. •
(Optionalpstamless steal cli:.. • • ••: •
NOA No.: 18-0119.02
Expiration Date: 03/13/23
Approval Date: 03/22/18
Page 2 of 7
2.2 EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
American Test Lab of South Florida
RT0202.02-18
ASTM C 1167
02/10/18
RT0621.01-16
ASTM C 67
09/09/ 16
RT0311.01-14
TAS 101
03/18/14
IBA Consultants, Inc.
4709-3
TAS 101
12/21/07
PRI Construction Materials
CVER-013-02-01
TAS 101
12/30/13
Technologies
CVER-014-02-01
TAS 102
03/11/14
CVER-015-02-01
TAS 100
04/07/14
Redland Technologies
7161-03 Appendix III
PA 102 & PA 102(A)
Dec. 1991
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
•
The Center for Applied
25-7094-(3, 6 & 9)
PA 102 • • •
M171994
Engineering, Inc.
25-7120-(1 & 2)
PA 102 •,,•
•Novi4994
25-7183-(3 & 4)
PA 102 ...;..
Fep. 1995
•
•
25-7214-(3, 4, &7)
PA 102 ....
March. 1995;•"';
0
25-7804-4
PA 102 0000
pep. I996
.....
......
....
.....
.. ..
....
......
. .
. .
.....•
. .
. • •
.. .
• . .
......
NOA No.: 18-0119.02
MIAMI•DADECOUNTY Expiration Date: 03/13/23
Approval Date: 03/22/18
Page 3 of 7
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Regulatory and Economic
Development Department — Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Verea "Spanish "S" Grade 1 and its components shall be installed in strict compliance with Roofw&
•
Application Standard RAS 118, RAS 119, and RAS 120. • • • • • • • • • • • •; •
4.2 Data For Attachment Calculations.
...... .. . ......
Table 1: Average Weight (W) and Dimensions (I x w) • • • • • • •
Tile Profile
Weight-W (Ibf)
Length -I (ft)
Verea "Spanish S" Grade 1
8.0
1.625
:66: 0.904%, '
Table 2: Aerodynamic Multipliers - A (ft3) : : ..
Tile
A (ft3)
: .J�4ft3) :.
Profile
Batten Application
Directbeck App� dkton '
Verea "Spanish S" Grade 1
N/A
0.31
Table 3: Restoring Moments due to Gravity - M9 (ft-Ibf)
Tile
2":12"
3":12"
4":12"
5":12"
6":12"
7":12"
Profile
or Greater
Verea
Direct Deck
Direct Deck
Direct Deck
Direct Deck
Direct Deck
Direct Deck
"Spanish S"
6.46
6.36
6.21
6.01
5.74
5.40
Grade 1
NOA No.: 18-0119.02
MIAMI•DADE COUNTY Expiration Date: 03/13/23
"'' ' Approval Date: 03/22/18
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mechanically Attached Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(min 15/32"
(min. 19/32"
plywood)
plywood)
Verea "Spanish S"
Grade 1
2-10d Ring Shank Nails
28.6
41.2
n/a
1-10d Smooth or Screw Shank
5.1
6.8
n/a
Nail
2-10d Smooth or Screw Shank
6.9
9.2
n/a
Nails
1 #8 Screw
20.7
20.7
n/a
2 #8 Screw
43.2
43.2
n/a
1-10d Smooth or Screw Shank
23.1
23.1
n/a
Nail Field Clip)
1-10d Smooth or Screw Shank
29.3
29.3
n/a
Nail Eave Clip)
2-10d Smooth or Screw Shank
Nails Field Clip)
27.6
2 1.6.'.
"`rt/a •
•
2-10d Smooth or Screw Shank
Nails Eave Clip)...
38.1);
�n/a
`
Table 5: Attachment Resistance Expressed as a Moment - Mf ff .4bft
.;*go.
for Mechanically Attached Systems "
' • • `
Tile
Fastener Type
Direct Deck
Direi:t Deck
Battens go
Profile
(min 15/32"
(mine 19/92"
:""'
plywood)
plywood;
0 • • o -
g 0
Verea "Spanish S"
2-10d Ring Shank Nails'
33.1
48.1
n/a
Grade 1
1 Installation with a 4" the headlap and fasteners are located a min. of 21/" from head of tile.
' Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Verea
ICP Adhesives Polyset AH-160
63.212'
"Spanish S" ICP Adhesives Polyset AH-160 58.62
Grade 1
1 Large paddy placement weight 34.6 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160.
2 Medium paddy placement weight 24.5 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-
160
NOA No.: 18-0119.02
CMIAMIi7R�DE COUNTY Expiration Date: 03/13/23
• ' Approval Date: 03/22/18
Page 5 of 7
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed
below, or following statement: "Miami -Dade County Product Control Approved".
VERE SPAIN CE
LABEL FOR VEREA "SPANISH S" GRADE 1
(LOCATED ON THE SIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code
in order to
properly evaluate the installation of this system.
.. 0
. .
....
......
......
.. .
......
•....•
....
.. ..
.....
......
....
.....
.. ..
•..•
......
. .
. .
•....•
•• •
•• •
. .
NOA No.: 18-0119.02
CM1AM1W-DADMEC0=UNTY Expiration Date: 03/13/23
�FJZMSYJ Approval Date: 03/22/18
Page 6 of 7
1(
PROFILE DRAWING
VEREA "SPANISH S" GRADE I
. .
....
......
......
.. .
......
....
.. ..
.....
......
00000
.00:0:
.
,
. .
. .
......
•• .
•• •
• •
•
VEREA HURRICANE CLIP
NOTE: USE OF CLIP IS OPTIONAL. REFER TO MANUFACTURERS PUBLISHED INSTRUCTIONS FOR
INSTALLATION DETAIL
END OF THIS ACCEPTANCE
NOA No.: 18-0119.02
MIAMI•DADE COUNTY Expiration Date: 03/13/23
' Approval Date: 03/22/18
Page 7 of 7
GREEN SUSTAINABLE ATTRIBUTES
SCOPE: This document is solely for the purpose of verification of Sustainable Attributes of construction materials. The
documentation submitted has been reviewed by Miami -Dade County Product Control Section.
G.1 - SOLAR REFLECTANCE AND THERMAL EMMITANCE
Component Name
Initial
Aged
Initial
Aged
Solar Reflectance
Reflectance
Reflectance
Emmitance
Emmitance
Index (SRI)
1. Verea "Spanish S"
0.39
Pending
0.83
Pending
41
Grade 1
. .
....
..... .
.. .
.. .
.
. .
......
.. .
..... .
......
....
.. ..
.... .
......
....
00000
.. ..
....
......
. .
.
. .
. .
......
.
00.
.. .
.. .
. .
NOA No.: 18-0119.02
lffimmmmADE COUNTY Expiration Date: 03/13/23
Approval Date: 03/22/18
Page 8 of 7
M IAM FDADE
�m�ry MIAMI-DADE COUNTY
1 PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economy
Polyglass USA Inc.
I I I I W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product ContWj&ction
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the ri�lat to h0e Ibis' ......
product or material tested for quality assurance purposes. If this product or material fails to perforn; in the ao capted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediate19 rCvoke, modify! or ease**
suspend the use of such product or material within their jurisdiction. RER reserves the right*Wb ttake this acceptance; ....
if it is determined by Miami -Dade County Product Control Section that this product or material Mibs to mett the: 0•
.... • • • • 00000
requirements of the applicable building code. .•
This product is approved as described herein and has been designed to comply with the Flor' ;0 uildin e • *000
P PP g P Y .ld A g'Cs4�. 0000:0
including the High Velocity Hurricane Zone of the Florida Building Code. 000000 0 .
DESCRIPTION: Polyglass Polystick Underlayments
•• • •• •
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and•f1 11bwing
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
• 0 0 0 • •
.0000
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product
Dimensions
Specification Description
Polystick IR-Xe
65' x 3'3-3/8"
ASTM D 1970 A fine granular/sand top surface self -adhering, APP
Manufacturing
Or 65' x 3'
polymer modified, fiberglass reinforced, bituminous
Location #1 & #2
60 mils thick
sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick Dual Pro
61' x 3'33/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designedd*ts.a • • • • •
Location #2
metal roofing and roof tile undellaynZent. •• �.
Polystick Tile Pro
61' x 3'33/8"
TAS 103 and A rubberized asphalt self-adheTAN glass-frbe&palyester• • • • •
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing mem 0: *.•Designed rasa metal....
Location #2
roofing and roof tile underlayrrignt. • •
... • • • • • .. • .
Polystick TU Max
65'8" x 3'3-3/8"
TAS 103 and A rubberized asphalt self-adhel-"e,*A)lyestgf rein forced• • 9 • -
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a a raaf file ""'"
• • • • • . .
Location # 1 & #2
0
underlayment. 0*0000
Polystick TU P
32' 10" x 3'33/8"
TAS 103 and A rubberized asphalt waterprobfrrj'ipembt'ane, glass- • •
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular Orfa6e. '
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65' x 3'33/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location #1 & #2
Polystick MTS
65'8" x 3'33/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick NITS Plus
65'8" x 3'33/s"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
Location #2
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'3-%"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Trinity I ERD
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
10/19/11
P40390.08.12-2
ASTM D 1623
08/07/12
P37590.07.13-1
ASTM D6164
0492/13
P45270.05.14
TAS 103, TAS 110 & ASTI: DL02,3
�416�?!/14
P46520.10.14
ASTM D 1623
. TQJM j/ 14
P44360.10.14
TAS 103 & TAS 11d
110/67/14
P43290.10.14
ASTM D 1970 & TAS I
Id/17/14
PLYG-SC10130.06.16-3
TAS 103 & TAS I I1Y.....
•.0.6»;1/16
PLYG-10130.06.16-1
ASTM D1970 & TAS IIQ...
.W;7/16
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
*X/19/06
PUSA-055-02-02
TAS 103
12/ j 0/07
PUSA-089-02-01
TAS 103/ASTM D4798 &*G15S
. .
; W/06/09
Momentum Technologies, Inc.
JX20H7A
TAS 103/ASTM D4798 & G155
�•44/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23D8A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick NITS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1:
Wood, non -insulated
Deck Description:
Min. 19/32" plywood or wood plank .... ......
System Type E(2):
Anchor sheet mechanically fastened to deck, membrane adhered • • • • • • •
Anchor/Base Sheet:
...... .. . ......
One or more plies of ASTM D 226 Type II or ASTM D 2626. ...:..
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a w ihtfium 4" h2a4 lap. (for •
base sheet only) • • • • • 0 "" •
Membrane:
Elastoflex S6 G, hot asphalt applied • • • • • • • • ......
Surfacing:
......
See General Limitations Below. • � •
. . . . ......
•
. . ••••••
Deck Type 1:
Wood, non -insulated • • • • •
Deck Description:
Min. 19/32" plywood or wood plank
System Type E(3):
Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet:
One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet:
Polystick NITS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane:
Polystick TU Plus, self -adhered.
Surfacing:
See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Progrjqt.Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The !lashing tapgshiX•be •�
pressed in place and formed around the protrusion to ensure a tight fit. A second laye'i•'o'f.Pdlystick thaM be • • • • • •
applied over the underlayment. • • • �....
• . . .0000
Y
GENERAL LIMITATIONS: •••••• •••• •••..
.. .. ......
1. Fire classification is not part of this acceptance. .... • • • • • • •
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and PoE sticl;MTS•Plus•rnay be......
......
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, rocsf tiVsystems and quarry •
slate roof assemblies. " ' .00 '
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex osure Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
MIAMIOADE COUNTY Expiration Date: 09/13/21
F-1201,041 Approval Date: 07/06/17
Page 5 of 8
Rule 61 G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS Plus
MTS Plus with
Dual Pro
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:11 •••
6�1.2•
without battens
`
Profiled
Prohibited
4:12
6:12
6:12
4:12":'
VI2•
Tile
without battens
.....
•••••
• • • • Y
The above slope limitations can be exceeded only by using battens in accordance with t1lenproved"Id System•;•••
Notice of Acceptance and applicable Florida Building Code requirements. When battens arerequire8,,*"ey sha1P
.. .. .... ......
be utilized during loading and installation of tiles. •••••• ••
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid drop
irpf ....:.
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loaQing prpcedui'e —two tiles;••••:
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, Mr a total of •U'4% — foT• •
all underlayments except Polystick MTS which shall be loaded onto battens.
0
a
0
rn
N
fO
POL`YST1CKTU Plus
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLIC,&T.I.ONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIOIS....' ......
1. Polyglass does accept the direct application of Polystick underlayment membranes to woof #Decks. Ixgtailers are....:.
cautioned to refer to applicable local building codes prior to direct deck installation to dMtire this is acceptable. ; o 0 o o
Please also refer to applicable Product Data Sheets of the corresponding products. ."". . ; •
.... .. .. 00000
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge caam as per.P.olyglass ..;...
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimumof Vsrmetal�d,sk as .....0
required in Miami -Dade County or simplex type nail as otherwise allowable in other rjg?gs: at a minimum rate •
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail al -ea, area par$ F"vX" on • • • • o •
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to.coverthe area beint..00:
back -nailed. (Please refer to applicable local building codes prior to installation.) 00 0 • go 0 0. ' '
00
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of TV12" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
MIAMI•DADECOUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICAT.IPNS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMmE N DA TIOIS...
•
... •
�.
END OF THIS ACCEPTANCE
....
.. ..
.... .
......
....
.....
....
....
•...•.
. .
. .
......
NOA No.: 17-0614.22
MIAMI•DADECOUNTY Expiration Date: 09/13/21
UUMIM1 Approval Date: 07/06/17
Page 8 of 8
MIAMI-DADE COUNTY
M#M PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economv
ICP Adhesives and Sealants, Inc.
12505 NW 44' Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have tWs, product
or material tested for quality assurance purposes. If this product or material fails to perform in the•accepted.manner, the.....
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or sus
Vend he use
of such product or material within their jurisdiction. RER reserves the right to revoke• fts •acceptance! *If it is- • • • •
determined by Miami -Dade County Product Control Section that this product or material faifs'1' fftet the reViremenZ...
of the applicable building code. •
.... .. .. .....
This product is approved as described herein, and has been designed to comply with the: Florida Building Cody. ; • •
including the High Velocity Hurricane Zone of the Florida Building Code. • • • • • • • • • • • • • •
. . . . ......
DESCRIPTION: ICP Adhesives Polyset® AH-160 • • • • •
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state •atOfollowing
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
op-� ,rI'
MIAMI•DADE COUNTY
1141117151
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test
Specifications
ICP Adhesives N/A TAS 101
Polyset®AH-160
ICP Adhesives Foam N/A
Dispenser RTF1000
ICP Adhesives ProPacV N/A
30 & 100
Product Description
. .
Two component polyWr ;ne
.... .....
foal adhesive.
•.
06
•
Dispensing Equipment • • • • •
•
....
.. ..
.....
Equipment.
•
Dispensing G G..
....
..:..
.. ..
Goes
......
......
•
. .
G •
......
e.GG•.
PRODUCTS MANUFACTURED BY OTHERS: •
. • ......
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which lis!*VtOment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball, TX.
PHYSICAL PROPERTIES:
Property
Test
Density
ASTM D 1622
Compressive Strength
ASTM D 1621
Tensile Strength
ASTM D 1623
Water Absorption
ASTM D 2127
Moisture Vapor Transmission
ASTM E 96
Dimensional Stability
ASTM D 2126
Closed Cell Content ASTM D 2856
Results
1.6 lbs./ft.'
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Ft2
3.1 Perm / Inch
+0.07% Volume Change @ -400 F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
M AMi•aaDeeouNTY Expiration Date: 05/10/22
"' • ' Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
#94-060
257818-IPA
25-7438-3
25-7438-4
25-7438-7
25-7492
NB-589-631
9637-92
01-6743-011
01-6739-062b[1]
7050.02.96-1
P36700.04.12
P39740.02.12
528454-2-1
528454-9-1
528454-10-1
520109-1
520109-2
520109-3
520109-6
520109-7
520191-1
520109-2-1
Test Name/Report
TAS 101
TAS 101
SSTD 11-93
SSTD 11-93
SSTD 11-93
ASTM D 1623
ASTM E 108
ASTM E 108
ASTM E 84
•
•
TAS 114
ASTM D 1623
��•°••
TAS 101
•�••�•
TAS 123
�•��•�
TAS 101
......
TAS 101
•• •
TAS 101
Date
04/08/94
12/ 16/96
10/25/95
11 /02/95
12/ 12/95
02/01 /94
04/30/93
11 /4 6A4
01146 OA.�
•• Y
03 /14/9'6
04/ 18?12
10/23498
12/Q6/98
03/02/99
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
=MLAWWADECUNTY Expiration Date: 05/10/22
"' • ' Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before nppkcation
of any adhesive. The mix ratio between the "A" component and the "B" component sh$11 b�%aintaintd•between••....
1.0-1.15 (A): 1.0 (B). •• •• •'
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser:Ijjj400 or ICP.
Adhesives ProPack® 30 & 100 dispensing equipment only. 0 0
7. ICP-Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight.
...... .... .....
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutas.lfiallCP a4 ,fes •••, •
Polyset® AH-160 has been dispensed. • • • • • • •
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance withh%.%
'Placement Details' herein. Each generic tile profile requires the specific placement noted hei: in. •� �....�
NOA No.: 17-0322.03
MIAMI.DADECOUNTY Expiration Date: 05/10/22
"' • ' Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
edge) 20-25 sq. inches each
bead
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams yp4gr pan
. .
•
....
......
•
LABELING' •••:••
•
•• •
% ••••
All approved products listed herein shall be labeled and shall bear the imprint or identifiable rnV{ j,11g of the .
manufacturer's name or logo and following statement: "Miami -Dade County Product Control ApprVed"
or theZltlYami- .. �.. •
Dade County Product Control Seal as shown below. • • • • • •
000000
......
cE u,��.u�a , • • • • • • •
r.'711LSC�1'J • • •
BUILDING PERMIT REQUIREMENTS: •
As required by the Building Official or applicable building code in order to properly evaluate the installation oithis
system.
•
••••••
NOA No.: 17-0322.03
MAMI•DADE COUNTY Expiration Date: 05/10/22
' "' • ' Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
Nag thm"k plastk tam mt wdkly lBanarlk7 •y
{w on raqulrswil
Vnd•rlaym•na a •�`�"
6weC9nnHr�
2
Ew.Claw"___
Nall through Piss* aemeM
rwhen requlreM
P*4149 43"sath Tool
-(jirltiYprs+�nYIMIC �
�.
I ha i
2ln.wld•`yr
Battem"S opal al
.
clasurr
rmwcoursa
Fasdr
1hr+�+l9fi plAai� ilyddl�' IBdn.+dhTll.l
twhan MR=
P
tFndl+erryn+�.fe o
tprn.11 �`
2 in, w4dr
J'f F
`. 9ifVa lVffilll � � l+.iLEir
./ w1ph0fe
Ernrclssure
i01n in, Orlpedge
CMIAMI-DMADEMUMNTY
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x (25.4*ipp�.lbam • • �. •.
paddy onto the underlayrriggr;gsitionej as shown
under the pan portion of tj}g.t "closeA491V • • • • • •
overlock of the tile beingsft:.. •
. . . . rrr.r
2. Continue in same mannerApisare appro rim ely 17 0
(109.7 cm2) — 23 (148.4 cmtesglare irj& l ftesive ""'
contact with the undersidebf'ttle tile. "" ' • • • •
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11.
Nail through plastic cerneM
4wben retuiredl
I,,
swens cpteunal
MIAMI•DADE COUNTY
ADHESIVE PLACEMENT DETAIL # 2
Fay. [tosw•
Fard•
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm2) - 12(77.4 cm2) square inch adhesive
contact with the underside of the tile. • • • •
. . .... ......
. . •
.. . .. . •
Medium Profile / Double Pan Ti11 000000
• • •
•
1. Starting at the eave course, ajDpi' a�ninimum 2"�(50.8 •
.. .. .. .....
mm) x 10" (254 mm) x 1" (25mrp) foam.gqjcdy •.;..'
onto the underlayment positigge4.8 shovv%ijQdCr the .....o
pan portion of the tile closest tp tjv Overlock of the •'
tile being set. Insure approxidiate'1y:17 (100.7 •cm2) — • • • • • •
23 (148.4 cm2) square inch adhesive contact with the ;
underside of the tile. • • • • • '
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
N&N 0weugh pknt k ce
twhen roq+ulMd)
caddy IH+rw r+hTil•)
s
7'
210,
Battens eptlonal
'+ r
�
�
EBW �
exie
vr..ph04
dowrc
arlpedlge
MIAMI•DADE COUNTY
..•
High Profile / Single Pan Tile
I . Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cmZ) —
23 (148.4 cmZ) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cmZ) - 19 (122.6 cmZ) square inch acllwrbive
•
contact with the underside of the tile. • • • • •
6.9 •
• • Go:*
as
•ea•e• •• •
......
......
a
a
.... .. ..
.....
•a•aa• ....
.....
.. .. ....
......
. . . .
......
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
Nail through plastic cement paddy (between tfles)
(when requlredl
Battensoptiwnl °
Pa ddy hinder tite)
anntopdt� r
ti
pa .�
x 4 In'
s- nnggttee letii d •,
single paddy
on ended: 2 x 41n.
To
21n
nave dcsure
Flat/Low Profile Tile
Nall through plastic cement Single paddy under tie
(when required)
Paddy (between tiles)
Battens Paddy (under tile}
optional
Single
on top off lie
�ix4In. ~ x41n
spaddyle
torn.~ tin.
Eve Closure
Eve Course Fasda
Medium ProfileTlle
APPROVED
1. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x V (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in' (109.7-148.4 cm') of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the un4erjgck for
the second course tile to 1;e in4alled. Tr"we' • • • • • •
approximately 8-9 in (5 r.0-6n.I cm2) of adhesive •
contact with the underside,44k@ tile. • • • • • • • • • •' •
(Instructions continued on nexep&ft) e • • • • a • • • •
.... .... ......
• • • • Y
•• • •• • • •
•• •
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Nap thromp plastic Single paddy under the
-
A
(when rerluked)
Paddy ibetween tiles)
Battens f r'�y
o'ptio'na4.,.J
Paddy (under tile)
on urmapedma r.
�4x♦in.
Singe 2 s 4 in
w -
top 01 the
..
"•
Eave Course
cla
Weephole
loin. In.
Eave closure
v'
Drip —
High Profile Tile
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x %"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71 cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm') - 9 (58.1 cm') square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
••••••
••••
•••••
••
••••
••••••
••
•
•
• •
••••••
•
NOA No.: 17-0322.03
MIAMI•DADE COUNTY Expiration Date: 05/10/22
• r
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
1) Place enough adhesive to achieve 65 to 70 sq. in. Stoop pitch applications
In contact with the pan tile. (when required)
2) Turn coven upside down. Place adhesive In
to 1 in. from outside edge of cover tile.
Than Install the tile. Ensure 20 to
25 sq. in. contact area.
Vnderlayment
Eave closure
(motar shown)
Fascia
Remove top portion of the owe course cover tile. Abut to second course of
pan tiles. Ensure save and of pan and cover tiles are flush at eave One.
Two Piece Barrel - High Profile Tile
APPROVED
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cmZ) — 70 (451.6 cmZ)
square inch adhesive contact with the underside
of the pan tile.
3. Turn covers upside down exposing the underside
of the tile. Apply a minimum 1" (25., 1M) x 10"
(254 mm) bead of adhesive directly bake inner e e e e e e
edge of each side of the'QVer tile. Leave • •,
approximately 3/4" (19el1 iqx eto 1" (TSt4 r71m) • • • • • •
from the outside edge oftkethe, inward free of
foam to allow for expaV(M.• • so
eeee •e •e eeeee•
4. Turn cover tile over aftesr VaM is applied and •
.. ea •0••
place onto pan tile course. Insure a minnpum of •
ee ee
20 (129 cmZ) - 25 (161. crrT );quareeiinch• Goo*:*
contact area on each sidg of the covet tile 16the •
pan tile. Continue in salt Aarsner. Trim aavay e •
any cured exposed foam adhesive. Poioing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17