Loading...
RC-08-20-1662 SOLAR PV SYSTEM INSPECTIONEDUARDO R. BAS P.E. FLORIDA ENGINEER LICENSE #77463 8940 SW 155th ST. PALMETTO BAY, FL 33157 TEL: (305) 479-2592 DATE: 9/15/2020 TO WHOM IT MAY CONCERN: PROJECT: VICTOR DE JESUS ADDRESS: 150 NW 99TH ST MIAMI SHORES, FL 33150 SYSTEM: GRID -TIED PV SYSTEM PROCESS #: RC-07-20-1499 CONTRACTOR: CUTLER BAY SOLAR SOLUTIONS SPECIAL INSPECTOR CERTIFICATION LETTER: 1. I, EDUARDO BAS, PE# 77463, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE INSTALLATION OF THE ATTACHMENTS FOR THE SOLAR PV SYSTEM TO THE EXISTING ROOF STRUCTURE AT THE ADDRESS ABOVE HAS BEEN INSPECTED AND IT IS ACCORDING TO PLANS. TOTAL ROOF MOUNTS INSPECTED TYPE OF ATTACHMENT: TYPE OF LAG -BOLT: MAXIMUM SPAN BETWEEN MOUNTS SEALANT USED: METHODOLOGY OF INSPECTION: 44 ALUMINUM L-FOOT 5/16 inch SS LAG BOLT 3 INCH INTO 2x6 TRUSSES 24" OC 4 FEET DURALINK NON -SLUMP POURABLE SEALANT & DURALINK NON -SLUMP BASE SEALANT INSPECTION OF ROOF ATTACHMENTS HAS BEEN PERFORMED FOLLOWING THE FOLLOWING STEPS: o REVIEW OF ON -SITE PHOTOS TAKEN DURING THE ATTACHMENTS INSTALLATION IN ORDER TO DETERMINE NUMBER AND LOCATION. o REVIEW OF STRUCTURAL PLANS PRESENTED TO THE AHJ TO ENSURE A PROPER LAG -BOLT SIZING HAS BEEN CHOSEN. o A SAMPLE OF A MOUNT HAS BEEN ANALYSED TO ENSURE THATTHE ELEMENTS PRESENTED ON STRUCTURAL PLANS (CORRECT LAG -BOLT SIZE, L-FOOT AND FLASHING SYSTEM) ARE INCLUDED. FOR FURTHER QUESTIONS, PLEASE DO NOT HESITATE TO CONTACT ME AT (305) 479-2592 SINCERELY, EDUARDO R. BAS (P.E.). �..