RC-08-20-1662 SOLAR PV SYSTEM INSPECTIONEDUARDO R. BAS P.E.
FLORIDA ENGINEER LICENSE #77463
8940 SW 155th ST.
PALMETTO BAY, FL 33157
TEL: (305) 479-2592
DATE: 9/15/2020
TO WHOM IT MAY CONCERN:
PROJECT: VICTOR DE JESUS
ADDRESS: 150 NW 99TH ST
MIAMI SHORES, FL 33150
SYSTEM: GRID -TIED PV SYSTEM
PROCESS #: RC-07-20-1499
CONTRACTOR: CUTLER BAY SOLAR SOLUTIONS
SPECIAL INSPECTOR
CERTIFICATION LETTER:
1. I, EDUARDO BAS, PE# 77463, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE
INSTALLATION OF THE ATTACHMENTS FOR THE SOLAR PV SYSTEM TO THE EXISTING ROOF STRUCTURE AT
THE ADDRESS ABOVE HAS BEEN INSPECTED AND IT IS ACCORDING TO PLANS.
TOTAL ROOF MOUNTS INSPECTED
TYPE OF ATTACHMENT:
TYPE OF LAG -BOLT:
MAXIMUM SPAN BETWEEN MOUNTS
SEALANT USED:
METHODOLOGY OF INSPECTION:
44
ALUMINUM L-FOOT
5/16 inch SS LAG BOLT 3 INCH INTO 2x6
TRUSSES 24" OC
4 FEET
DURALINK NON -SLUMP POURABLE SEALANT
& DURALINK NON -SLUMP BASE SEALANT
INSPECTION OF ROOF ATTACHMENTS HAS BEEN PERFORMED FOLLOWING THE FOLLOWING STEPS:
o REVIEW OF ON -SITE PHOTOS TAKEN DURING THE ATTACHMENTS INSTALLATION IN ORDER TO
DETERMINE NUMBER AND LOCATION.
o REVIEW OF STRUCTURAL PLANS PRESENTED TO THE AHJ TO ENSURE A PROPER LAG -BOLT SIZING HAS
BEEN CHOSEN.
o A SAMPLE OF A MOUNT HAS BEEN ANALYSED TO ENSURE THATTHE ELEMENTS PRESENTED ON
STRUCTURAL PLANS (CORRECT LAG -BOLT SIZE, L-FOOT AND FLASHING SYSTEM) ARE INCLUDED.
FOR FURTHER QUESTIONS, PLEASE DO NOT HESITATE TO CONTACT ME AT (305) 479-2592
SINCERELY,
EDUARDO R. BAS (P.E.). �..