Loading...
RC-07-20-1551 PILE DRIVING INSPECTIONEc DYNATECH ENGINEERING CORP. WWW.DYNATECHENGINEERING.COM Miami, March 2, 2021 Mr. Chris Lopez J.L.U. ENTERPRISES, INC. 2800 NW 32nd Avenue Miami, FL 33142 Re: Proposed Interior Renovation @ 1301 NE 101S1 Street Miami Shores, FL 33138 Dear Mr. Lopez: Pursuant to your request, DYNATECH ENGINEERING CORP. performed a site inspection on March 2, 2021 at the above referenced project. The purpose of our inspection was to document pile driving operation. All piles consisted of 3 inches diameter pin piles, placed at the location marked by the client to the depth indicated on the attached field logs to achieve a bearing capacity of 5 tons in compression. Driving was performed using a MB 2570 Hammer. All piles were driven to refusal. Enclosed find copies of our field log inspection. It has been a pleasure working with you and look forward to do so in the near future. Sincerely yours, Wissam aamani, P. E. DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector No. 757 Certificate of Authorization No.: CA 5491 `:�c�P•L�CEhIs�:'q�9y :• No. 39584 •: STATE OF f4ORto�-' �. ��~ �F'`•r SS.I- - �"""% 750 WEST 847H STREET, HIALEAH, FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFO®DYNATECHENGINEERING.COM REPQRT QF PILE PRIVINQ INSPECTIQN DYNATECH REPORT OF PILE DRIVING INSPECTION ENGINEERING CORP. CLIENT : J.L.U. ENTERPRISES, INC. DATE: March 2, 2021 PROJECT : Proposed Structural Renovation @ HAMMER USED: MB 2570 ADDRESS : 1301 NE 101s' Street. Miami Shores. FL PAGE No.: 1 of 1 PILE TYPE PILE No. 1 2 3 4 5 6 REMARKS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 5 sec 5 sec 5 sec 5 sec 5 sec 5 sec 1 5 sec 5 sec 5 sec 5 sec 5 sec 5 sec 2 10 sec 10 sec 15 sec 10 sec 15 sec 10 sec 3 15 sec 15 sec 15 sec 15 sec 15 sec 15 sec 4 35 sec 15 sec 35 sec 15 sec 35 sec 35 sec 5 35 sec 35 sec 35 sec 35 sec 35 sec 35 sec 6 35 sec 50 sec 50 sec 35 sec 35 sec 50 sec 7 50 sec 50 sec 50 sec 50 sec 50 sec 50 sec 8 50 sec 1:00 min 1:00 min 50 sec 1:00 min 1:00 min 9 1:00 min 1:00 min 1:00 min 1:00 min 1:00 min 1:00 min 10 1:30 min 1:30 min 1:30 min 1:30 min 1:30 min 1:30 min 11 1:30 min 1:30 min 1:30 min 1:30 min 1:30 min 1:30 min 12 1:30 min 1:30 min 1:30 min 1:30 min 1:30 min 1:30 min 13 1:30 min 2:00 min 2:00 min 1:30 min 2:00 min 2:00 min 14 1:30 min 2:00 min 2:00 min 2:00 min 2:00 min 2:00 min 15 1:30 min 2:00 min 2:00 min 2:00 min 2:00 min 2:00 min 16 2:00 min 3:00 min 3:00 min 2:00 min 3:00 min 3:00 min 17 2:00 min 3:00 min 3:00 min 3:00 min 3:00 min 3:00 min 18 2:00 min refusal refusal 3:00 min refusal refusal 19 2:00 min refusal 20 5:00 min 21 5:00 min 22 5:00 min 23 refusal 24 25 26 27 28 29 30 31 32 33 34 35 Pile Size (Inches) 3" 3" 3" 3" 3" 3" Length (Feet) 7' 7' 7' 7' 7' 7' Bearing Required (Tons) 5T 5T 5T 5T 5T 5T Penetration Last 5 Blows N/A N/A N/A N/A N/A N/A Formula Tons (Tons) 5+ 5+ 5+ 1 5+ 5+ 5+ Depth Driven Feet 24' 19, 19' 1 20' 19' 19' NOTE: Depth Driven Refers to Existing Ground Elevation at time of installation. Field Tech: R.N. SITS PLAN 0 U l7 o Z OHS OL .r US OD Lj Z I.- in Z L d OD CD W W~cmOODDWCU U 170J{A{nH la W{_ MMZ = W =Q ^ ^ q W3 JWLL.QO in a W N Z ao W M INpfl�Ylx � F 014fA1 Nk►r1 p v% � CD - 13 1=4f N Z p o r Ce) M M f < f M W W �Nr J CL U C Q: W (U H O N W N F- Z F- _ = J O L) J } Z f � A � ~ Z ,Zi Z IW— rW-� Q Q Q J A U A A