RF-12-20-2877 TILE UPLIFTGEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS 1 ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES
€c DYNATECH ENGINEERING CORP.
W W W.DYNATECH ENGINEERING.COM
STANDARD PROCEDURE FOR FIELD VERIFICATION OF THE BONDING OF
MORTAR OR ADHESIVE SET TILE SYSTEMS AND MECHANICALLY ATTACHED,
RIGID, DISCONTINUOUS ROOF SYSTEM
DATE: APRIL 7, 2021 Permit # RF-12-20-2877 ONLA -k
CLIENT: DESIGN HOME REMODELING CORP. 290 NW 16151 Street Miami, FL 33169
ROOF ADDITION ONLY AT: 561 NE 106TH STREET MIAMI SHORES, FL 33138
Testing Equipment: Humboldt Scale Model H-4620.
The test results presented here reflect the condition of the roof system at the time of the test. These results are time and sample
dependent since roof condition are continuously changing due to the exposure to the element and roof top traffic. Client recognizes
that actual conditions in areas not tested by Dynatech Engineering Corp (DEC) may differ from those anticipated in DEC's report.
Client understands and accepts that this can significantly increase the cost of construction for its future projects. Client agrees that
DEC shall not be responsible or liable for any variations in the actual conditions of areas not tested by DEC,
TEST NUMBERS
TEST LOCATIONS:
SEE SKETCH
FIELD UPLIFT
PULL TEST
TEST RESULTS
I-24
FIELD
> 35 LBS
PASSED
25-27
CORNER
> 35 LBS
PASSED
28-47
PERIMETER
> 35 LBS
PASSED
48-54
RIDGE & HIP TILES
> 35 LBS
PASSED
TILE TYPE/ATTACHMENT: Flat roof tile polyfoam set. INSPECTED BY: JM
ROOF TILE UPLIFT CAPACTIY IN ACCORDANCE WITH 2O20 FLORIDA BUILDING CODE, 7m EDITION, TEST PROTOCOL TAS-106
ROOFSKETCH
35'
25.. 40_..--- 41---------2 - .43_..'26
10, 39.9 8 7 6 5 ' 44 10'
38L, 1 2 3 4 ;45
7'
20,
10 II 12 13 14 ;46
i
37y '� 17 16 15 ;47 10`
24
36 18
30 29 - 28 - - J 7
23 31 21'
3 �
35,19 i 32
IEY
22
i
r
34i 20 �33
21 4 j
Sincerely yours,
sAAD
Wissam aamani, P.E. .•`�`SQ `. i� E s
DYNATECH ENGINEERING CORP. : �`�:= F'
�s
Florida Reg. No. 39584 = *�. No. 39584
Special Inspector No. 757 =
STATE OF
G,
'';SS/ONA�,.�`ti
Page 1 of %,''0rrr141M,,t%10
750 WEST 84TH STREET. HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM4