RF-11-20-2520 TILE UPLIFT11 Engineering & Testing Co. 7450 Griffin Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net March 1, 2021 To: Miami Shores Village Building Department 10050 NE 2"d Avenue Miami Shores, FL 33138 Roof Tile Uplift Test Report Test Date: March 1, 2021 Permit #: RF-11-20-2520 Address: Ditommaso Residence 295 NE 104 St, Miami Shores, FL Contractor: Paul Ban e Roofing Roof Pitch: 3:12 Attachment method: ICP Pol Pro AH 160 Tile Type: Eagle Bel Air Device Used: "IMADA DPS 110" Force Gauge Serial # 425 Total Sloped Roof Area: 27.00 squares All Testing is in strict accordance with the Florida Building Code, 2017 Edition, High Velocity Hurricane Zone — Testing Application Standard (TAS) 106. Roof Area: 27.00 squares Total Number of Tests Number of tests Passed % Passed Field Area (1): 12.00 squares 16 (T42-T57) 16 100% Perimeter Area (2): 15.00 squares 20 (T22-T41) 20 100% No. of Corner Areas 3 : 10 10 T1-T10 10 100% Ridee/Hio Areas: 165 ves 11 (T11-T21) 11 100% Based upon the field tests, I certify that 100% of the static up -lift tests "PASSED" the testing criteria of 35.0 lbf load, and meets the attachment resistance for adhesive Set Systems, as specified in the NOA. Should you have any questions regarding the above, or if require additional information, please do not hesitate to contact this office. Sincerely, CeBB Engineering & Testing Co. (NOA 18-1129.01) 02/05/2021 Eduard Badiu, P.E. Fla. Reg. No: 59997 For The Firm , Cc: Paul Bange Roofing Enc. Location Sketch Calibration Certificate Lc � V ap -1 &�'w Engineering & Testing Co. 7450 Griffin Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net HANDLIFT RESULTS: Passed the protocol criteria of less than 3% loose. We performed the up -lift test T — Tested tiles and Passed; Total Area: 27.00 squares No. of tested Tiles: F — Tested tiles and Failed; - Field Area (1): 12.00 squares - Field Area: 16 M — Missing Tiles; - Perimeter Area (2): 15.00 squares - Perimeter Area: 20 B — Broken Tiles; - No. of Corner area (3): 10 - Corner areas: 10 -Ridge/hip areas: 165 pcs - Ridge/Hip areas: 11 1' Legend: 42-57 Field tests 22-41 Perimeter tests 1-10 Corner tests 11-21 Ridge Tests TAS 106 TESTS LOCATION SKETCH Permit # RF-11-20-2520 Ditommaso Residence 295 NE 104 St, Miami Shores, FL Engineering & Testing Co. 7450 Griffin Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net TEST RESULTS (P = PASSED, F = FAILED) Test Location Uplift Pull Test or F Test Uplift Location Pull Test (P or F) Test Location I Uplift Pull Test P (P or F) Test Location Uplift Pull Test or Test Uplift Location Pull Test �� (P or F) 1 P 26 P 51 P 2 P 27 P 52 P 3 P 28 P 53 P 4 P 29 P 54 P 5 P 30 P 55 P 6 P 31 P 56 P 7 P 32 P 57 P 8 P 33 P 9 P 34 P 10 P 35 P 11 P 36 P 12 P 37 P 13 P 38 P 14 P 39 P 15 P 40 P 16 P 41 P 17 P 42 P 18 P 43 P 19 P 44 P 20 P 45 P 21 P 46 P 22 P 47 P 23 P 48 P 24 P 1 49 P 25 P 1 50 P Engineering & Testing Co. 7450 Griffin Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net PORG! h ORgU! MlAOURl MINT � F 190 AAnt RRC11,9TRRF_n 1.9()/IPr: 1rl13!1 ACf]Fl�C]ITf?n CALIBRATION CERTIFICATE Issue Dale: May 15, 2020 Calibration Date: May 15, 2020 Certificate N 051520-425458E Tcmperalure: 73 IF Humidity: 40 %Rll Description: Digital Force Gouge Model Number: DST -I IOA Serial Number: 425458 Capacity: I 10 Ibl' Accuracy: t0.2 %RS.t 1 LSD Resolution: 0.1 lbf Procedure: CXAOID QMF-I1-3-IM Description 5/N culifienre K Due Dale 9'emp/RH M'rR 16311987 :2031507 80-4/7021 Illangcr 2LL11 2871867A 311512021 W-B01 5FAX 7.562225) 3232022 'Weight 23H5 2807999C Amended 12/1/2020 Weight 23GR .2716545 3/222028 '1'11i4 document certifies that the above instrument has been calibrated and tested in accordance with Imada calibration procedures comlucted under the conditions noted with standards, which establish an unbroken link traceable to the International System of Units (SI) via the relevant primary national or international standards, including National Institute of Standards and Technology (MIST). This document nurst not be reproduced without written authorization from IMADA INC. TEST RESULTS TLST POINT ACTUAL ACI't1Ai. _ Il thus -110.0 Oho -110.0 OH -110.0 flbt) I 0.0 0.0 0.0 3) comp. 110.0 I M0 110.0 Technical Manager: Noboru LJmegaki Imudn, Inc. 3100 Dundee Rd., Suite 707 Northbrook, Illiuuia 60062 1,—Nwi W,: ul http://wlvw.imsda.com E-ltintl: imado(n)imadn.cum "00-373-9989 11-0mm mn I no 19 Page 1 of I