RF-12-20-2799 TILE UPLIFT6
C A 1. L A B, T� C.
i
February 4, 2021
Isaac's Roofing & Insulation
17225 South Dixie Highway, Unit 200
Miami, FL 33157
RE: TILE UPLIFT TEST
PROJECT INFORMATION PROVIDED BY CLIENT:
344 NE 102 St
Miami Shores, Florida
Property ID: 11-3206-013-5140
Permit 4: RF-12-20-2799
Date inspected: February 4, 2021
Date completed by: February 1, 2021
Roofing Contractor: Isaac's Roofing & Insulation
Carlab, Inc Project # 21-9047
Testing lab Certificate #: 19-0110.01
Dear Sirs,
In accordance with your request and authorization, a representative of Carlab, Inc completed the Roof
Tile Uplift Test at the above referenced project. This testing was performed in general accordance with
Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of
mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was estimated to be less than 2300 square feet, and the mean
height of the roof is less than 20 feet above ground surface. The type of tile used for this project was
reported to be Ceramica Verea Concrete/Clay Roof Tile. This tile was reported to have been foamed in
place.
At the time of this testing at least one test for every 3400 square feet of roof tile in the perimeter area,
one test for every 200 square feet of roof tile in the field area, and one test per corner were performed.
The results for this report are valid at the time of testing only. Walking on the roof or any other type of
physical disturbance may alter these results.
Based on our test results, we conclude that the installation of the roof tile at the above referenced
project meets the test requirement outlined in the above mentioned protocol. Attached please find a
copy of our test report for your review.
Should you bV@.V)4 e�tions or if we may be of further assistance, please do not hesitate to contact the
undersig '•.
E ••
Respect f�t • b
a
•° S TAT 6
S e rg i a �hi s7,t��
8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438
N
N 38
LJ
FLAT ROOF
EXISTING ROOF C❑VERING
NOT A PART OF THIS INSPECTI❑N
LEGEND
+ FIELD TEST
- PERIMETER TEST
O CORNER TEST
C A R L A B, I N C.
ENGNKII AND PLANNM
CPRTMCATE OF AUTEWRIMnON 6419
�J30 SW. 25 Sr, WAbM FL 33165 TM 305 293.T5121 AAM 303 22&"M
APPR❑X, R❑❑E TEST L❑CATI❑NS AND DIMENSI❑NS