Loading...
RC-20-1737 DENSITY TEST(zC-qz FIELD DENSITY TEST OF COMPACTED SOILS ASTNI D-6938-08a PROJECT: REAR ADDITION AT: 261 NE 102 ST MIAMI SHORES. FL Date: March 4. 2021 GEOTEC No. D-210304-001 MOISTURE DENSITY RELATIONSHIP (MODIFIED PROCTOR) ASTM D-1557-07 GAUGE SERIAL SOIL DESCRIPTION MAX. DRY OPTIMUM No. DENSITY MOIST. '/. 62691 LIMEROCK WITH LINIESAND 130.2 8.84 REQUIRED COMPACTION (%) 95% 1 TEST DEPTH PENETRATION (INCHES) 12 ORGANIC % N/A MATERIAL ON SITE BACKFiLL SUB -BASE BASE B. PAD I LBR VALUE LIFT I TOP I EXC. IMPORT I SOURCE -ARBONATH % DENSITN' TEST RESULTS TEST No LOCATIONS FIELD DRY DENSITY FIELD(%) MOIST. FIELD (%) COMP. RESULTS I RIGHT AREA OF REAR ADDITION SLAB 124.2 4.2 95.4 PASS 2 CENTER AREA OF REAR ADDITION SLAB 127.7 6.3 98.1 PASS 3 LEFT AREA OF REAR ADDITION SLAB 126.2 5.8 96.9 PASS 4 CENTER AREA OF LATERAL TERRACE SLAB 125.4 7.1 96.3 PASS Sieve Elie: 3" 2,/," 2" 1,/," 1" % ,/i" 3/8" #4 % Paolns Sieve Size: #10 #20 #40 #60 #80 0140 #200 WASHED r% Passing — DRY MOISTURE I DENSITY CURVE IJL uu 13000 128.00 126.00 } 124.00 v, 122.00 Z 0 120.00 } 0: 118.00 116.00 114,00 112L0.--.-- 6.67 % 8 84% 9 09% 11 63% MOISTURE CONTENT % ,IIIIIII�� CP III�1 GUC CONSULT GU[`P'�) ,rS T air Profess i rjj 2 State fldrkla' GEOTECHNICAL , CIVIL STRUCTURAL ENGINEERS — 13093 SW 133 CT. MIAMI , FL 33186 - P: (786) 319-0355 / P: (786) 380-0734 garcia5229@bellsouth net