Loading...
SGN-19-1290Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 06/27/2019 Location Address Parcel Number 9801 NE 2ND AVE, Miami Shores, FL 33138 1132060134380 Contacts Permit NO.: SGN-06-19-1290 Permit Type: Sign Work Classification: New Permit Status: Approved Expiration: 12/24/2019 9801 PARK LLC Owner 4141 NE 2 AVE 204 A, MIAMI, FL 33137 J.C. & ASSOCIATES GROUP, INC Contractor JUAN CARLOS LAGO 4141 NE 2 AVE, MIAMI, FL 33183 Business: 3052538225 Other: 3057423199 ns ecti Description: INDIVIDUAL BOX LETTER SIGN ON BUILDING Valuation: $ 2,222.63 Ion Reguests: CANOPY AS APPROVED IN ZONING HEARING OF 05/23/2019 AT 305-762-4949 AMARANTHINE NEW CORNER RESTAURANT IN EXISTING Total Sq Feet: 0.00 SHOPPING CENTER AMARANTHINE Fees Amount Application Fee - Other $50.00 CCF $1.80 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.60 Permit Fee $50.00 Planning and Zoning Review Fee $35.00 Scanning Fee $9.00 Structural Review ($45) $45.00 Technology Fee $2.50 Total: $197.90 Payments Date Paid Amt Paid Total Fees $197.90 Credit Card 06/27/2019 $147.90 Credit Card 06/05/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWN E-1FrlDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws rqg-u'iatinj ponstruction and zoning. Futhermore, I authorize the above named contractor to do the work stated. re: Owner / Applicant / Contractor / Agent Date June 27, 2019 Page 2 of 2 o� BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED JU 0 5 2019 BY: o G T FBC 20 F� Master Permit Nov GN 0 (:,- I C-iJ I 4 Sub Permit No. OBUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 9801 NE 2nd Ave City: Miami Shores County: Miami Dade Zip: Folio/Parcel#:11-3206-013-4380 Is the Building Historically Designated: Yes NO X Occupancy Type: A-2 Load: 150 Construction Type: III Flood Zone: X BFE: FFE: 10.35' OWNER: Name (Fee Simple Titleholder): 9801 Park LLC Phone#: 305 455 1800 Address: 4141 NE 2nd Ave. Suite #204A City: Miami State: FL Zip: 33137 Tenant/Lessee Name: AMARANTHINE RESTAURANT Phone#: 9543944140 Email: yiannikg@gmail.com CONTRACTOR: Company Name: JC & Associates Group Phone#: 305 742 3199 Address: 7741 SW 122 Ave City: Miami State: FL Zip: 33183 Qualifier Name: Juan Carlos Lago Phone#: 3057423199 State Certification or Registration #: CGC057500 Certificate of Competency #: DESIGNER: Architect/Engineer: Forever Signs Phone#: 305 740 0150 Address: 2400 West 3rd Court City: Hialeah State: FL Square/Linear Footage of Work: Value of Work for this Perm' . � �' 7-' 30 LF Zip: 33010 Type of Work: ❑ Addition ❑■ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Individual box letter sign on building canopy as approved in Zoning Hearing of 5/23/19 at Amaranthine new corner Restaurant in existing Shopping Center. Specify color of color thru tile: Submittal Fee $ C—J) • (M Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF $ DBPR $ CO/CC $ _ Notary $. Double Fee $ _ Bond $ (Revised02/24/2014) TOTAL FEE NOW DUE $ I `7 :� -"1V Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) --jy Mortgage Lender's Address City State Zip Zi Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. 1 e absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. 14 Signature Signature OWNER or AGENT C TRACTOR The fore oing instrument was acknowledged before me this day of 20 by I who is personally knovin to me or who has produced identification and who did take an oath. NOTARY PUBLIC: as The foregoing instrume t was acknowledged before me this ZI— day of , 20 by who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Wnirgip Print: Seal: ANAvSLAGO Nc;ati Plbitc - State of Florida CcrriSsion r GC 246553 Comr. Expires Oat 26. 2022 APPROVED BY Seal: ANAYS uG0 Notary Public - State of Florida Commission x GG 206553 My Comm. Expires Oct 26. 2022 oordeG nrough Natlonai Notary Assn. I IC- Plans Examiner GStructural Review lJ-16 Zoning Clerk (Revised02/24/2014) a SIGN MANUFACTURING 2400 W 3rd Court, Hialeah, FL 33010 Phone; (305) 885 3411 • Fax: (305) 885 3466 Email: foreversigns@aoi.com • http://www.foreversignsuso.com i �< CUSTOMER NAME AMARANTHINE ADDRESS 19801 NE 2ND AVE CITY _ STATE ZIP CODE MIAMI FL PHONE FAX _ I •�•'4 CHANNEL LETTER SIGN $1,58O.DO SPECS: .40 ALUMINUM RETURN 3/4" WHITE TRIM CAP TRANSLUCENTEACES LED LIGHTS $450.00 STEELSTRUCTURE LED LIGHTS ELECTRICAL CONNECTION FOR SIGNAGE $150.00 i50% DEPOSIT + 50% AT INSTALLATION _ MONTH DAY YEARNOTINCLUPED $2,180.00 $42.63 $2,222.63 We hereby propose to furnish labor and materials - complite with accordance with the above specifications, for the sum of dollars, plus 7% tax with the payment to be made as follows. Any alterations from above specifications involving extra costs, will be execute only upon written orders, and will become an extra charge over and above estimate. All agreements contingents upon strikes, accidents or delays beyond control This proposal subject to acceptance within days and void there after at the option of the undersigned. YOURSIGNATURECONSTITUTEANAGREEMENTTOTHECONDITIONSOFTHIS PROPOSAL. CUSTOMER SIGNATURE SELLER SIGNATURE & A CAST LLANOS SIGN MANUFACTURING 2400 W 3rd Court, Hialeah, FL 33010 SLo t-,3 - bo - (0( - ( /2- 91�) PROPOSAL CUSTOMER NAME F AMARANTHINE ADDRESS 9801 NE 2ND AVE CITY _ STATE ZIP CODE _ MIAMI ��L—�C PHONE FAX Phone: (305) 885 3411 • Fax: (305) 885 3466 Email: foreversigns@aol.com • httpJlwww.foreversignsuso.com Y � KG anGMAtL,I - __ ----+ J CHANNEL LETTER SIGN $1,580.00 SPECS: .40 ALUMINUM RETURN 3/4" WHITE TRIM CAP LED LIGHTS $450.00 STEEL STRUCTURE GRYLIC FACE LED LIGHTS ELECTRICAL CONNECTION FOR SIGNAGE $150.00 50% DEPOSIT + 50% AT INSTALLATION ____TQ1► MONTH DAY YEAR D4 23$2,222.63 �� $2,180.00 '►1� 1L'�(�f' $42.63 Ii>t I NOT INCLUDED We hereby propose to furnish labor and materials - complite with accordance with the above specifications, for the sum of dollars, plus 7916 tax with the payment to be made as follows. Any alterations from above specifications involving extra costs, will be execute only upon written orders, and will become an extra charge over and above estimate. All agreements contingents upon strikes, accidents or delays beyond control. This proposal subject to acceptance within days and void there after at the option of the undersigned. YOUR SIGNATURE CONSTITUTEANAGREEMENTTO THE CONDITIONS OF THIS PROPOSAL. CUSTOME SELLER SIGNATURE , ) A CASTELLAIVOS TRAVIS HENOALL Planning & Zoning Director *000�0'7- L r4�w 10050 N.E. SECOND AVENUE MIAMI SHORES. FLORIDA 33138-2382 TELEPHONE: (305) 795-2207 FAX: (305) 756-8972 DEVELOPMENT ORDER File Number: DO-STPL-000028-2019 Property Address: 9801 NE 2"d Avenue, Miami Shores, FL 33138 Property Owner: 9801 Park LLC Address: 4141 NE 2"d Avenue #204A, Miami, FL 33137 Applicant: Amaranthine Restaurant Address: 9801 NE 2"d Avenue, Miami Shores, FL 33138 Agent: Juan C. Lago Address: 10820 SW 200 Dr. #100, Miami, FL 33157 Whereas, the applicant 9801 Park LLC (owner), has filed an application for site plan review before the Planning Board on the above property. The applicant sought approval as follows: Pursuant to Articles IV, V and VI of Appendix A Zoning, Sec. 400 Schedule of Regulations and Sec. 600. Site plan review and approval required for a Sign. Whereas, a public hearing was held on May 23`d, 2019 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Planning and Zoning Board zoning approval is granted as shown on the plans submitted and made a part of this approval for a total for the site not to exceed 23.5 Square feet. Page 1 of 2 VISIT US I www.miamishoresvillage.com W 2) Applicant to apply for and obtain all required building permits from the Building Department before beginning work. 3) Applicant to apply for and obtain all necessary permits and approvals from outside agencies before beginning work. 4) Applicant to meet all applicable code provisions at the time of permitting. 5) This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. Additionally, the applicant must, satisfy all applicable Miami Shores Village Codes, Miami -Dade County Codes, the applicable building and life safety codes required for development, and provide a copy of the development order to the Building Dept. The application with conditions was passed and adopted this 23`d day of May, 2019 by the Planning and Zoning Board as follows: Motion to approve subject to Staff s recommendations made by Mr. Brady, Seconded by Ms. Hegedus and the Motion was approved 4-0. Mr. Snow Yes Mr. Bergman Absent Ms. Hegedus Yes Mr. Brady Yes Chairman Busta Yes 2�0 - ca�18� Date John Busta Chairman, Planning Board Page 2 of 2 N- h(,,- I.1 - 129 0 AMARANT_H I -NIE __ Aduo I I I-#) FZECEIVP,D JUN A a 2019 13Y: Southwest Elevation Project: Channel letters Sales Rep: Robin Perez I Date: 4/17/2019 Scale: N/A I Sheet: Add: 9801 NE 2nd Ave. Miami Shores, FI 5 gnsusa.net 305.US.3411 0 2400W3tdit, MOUNTING DETAILS CHANNEL INDIVIDUAL LETTERS WITKLE 0.40 Alum. return 1" Trim -cap 3° Toggle bolt - � Per Letter 1/8" Thick Mastic face a a Led self supported Attached w/3m vhb by Manufacturing suggested System as per nec 60041 a M 1/4" Drain holes 1/2" wire conduit w/ #12 wire, thnn.Thwn. (grounded) as per nec 600.24 ground wire (TRANSVERSAL VIEW):`'+.♦••_•..;,`'�, ♦ T -o � �jATEUF 7� Stucco on metal fame ,�Qti'•.. C 0kA '�!tlPg9✓tk41^�4 Transformer cane LED Transformer Alejandro Vargas P.E. License # 63894 20 Amps Lockable ALEJANDRO V 20 Amps Lockable switch. License # 63894 ,y� — 1025 Cedar Falls Dr. This Design Complies with Weston, FL 33327 2017 FdC pnd ASCE 7.16 Wind Speed : 1 "7 5MPH 701351 24.0 VDC power supply for up to 2.50 amps. Exposure i C— AWG # 18,2 conductor, PVC jacketed, NEC type power limited tray cable. (PLTC) with UL Listing. Used for letter to letter jumpers or extension of Power supply lead up to 15'. AWG #14,2 conductor, PVC jacketed, NEC type power limited tray cable (PLTC) with UL Listing. Used for extension of power supply lead up to 50'. UL Listed for wet location or NEMA 3R box, min. dimensions 12"xl2"xl6", vented (if power supply is to be mounted in a location exposed to weather). Cable tie downs (plastic with double sided tape for mounting). 4" nylon zip ties. Wire nuts (ideal P/N #30-072 blue). Sheet metal screws (#8 or #10) or rivets (1/8" or 3/16") for mounting frames. Rags or shop towels. Silicone sealant 1/2" conduct connectors for power supply primary (water tight if mounting power Supply in a box outdoors). Disconnect switch for primary power shutoff (see figure 13) Red Dot S323E, Leviton 1451-ICP or equivalent. The location of the disconnect switch after installation shall comply with Article 600.6(A) (1) of the National Electrical Code. ALL ELECTRICAL COMPONENTS ARE U.L. LISTED AS PER NEC 600.3 PRIMARY 120 VOLTS #12 WIRES BY OTHERS SIGN GROUNDED ACCORDING TO NEC 600.24 AND 600.7 CODES IN EFFECTARE NEC 2014/FBC2017, 6TH EDITION THE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY WITH ARTICLE 600.6(A) (1) OF THE NATIONAL ELECTRIC CODE EXISTING PRIMARY ELECTRICAL SOURCE (1/2" CONDUICT METAL SHOWN, WIRE #12 120 VOLTS NEC 600-6 & 600-21 NOTE: Time Clock and Photo Cell Required MOUNTING HARDWARE CHART WALL 3 MIN. PER LETTER •..' ..••• • a o� o o up W U 3/8" X 3" SUP-R-SLEEVE • • 1/4" X 3' BOLTS THRU WALL • • • ♦ f 1/4'X23/4"TAP CONS •••• • • 1/4" LAG BOLTS • • • • • • 3/8' X 6" TOGGLE BOLTS • • • • • #10 X 2" HEX SCREWS • 3/8" X 3" WOOD SCREWS • • • • PANEL SCHED E • •• ALL ELECTRICAL COMPONENTS ARE UL LISTED AND APPROVED • • • ALL SIGNS GROUNDED ACCORDING TO ARTICLE 600.3 OF THE N.E.C. I� � O� hl• � Itittti � � � Lb1D Pee NAA9E rorAL LMD EQST04G TOTAL AWS EMTTNG ELECTRICAL SERVICES DISCONNECT SNITCH FOSEDATiMAMPS® a)ATWCRjs) IE EROTR RE(%•iED 1 FN61NG PATH A M NID fY1N111TR,T 0.040 Alum LED Bumim Acrylic face 3Ar Bushin Clinched ar caLdked seE Drain hole LED SPECIFICATIONS Input Voltage 12VDC Module Level Power: 2.0 W/ft System Level Power: 2.25 W/ft Delivered Lumens:1 SO Lm/ft System Efficacy: 66 Lm/W Viewing Angle: 120* Correlated Color Temp: 4000K L70 Calculated Life: 99,000 Operating Temperature: -40 to 140°F ULrat ries LaboLaboratoories USTW MARK 9GN SECTION LABEL SHOWN ON EACH LETTER AS PER DMWNG ELECTRIC— No- NI f6 DLGDS) ONEeOXO ONEROX p� A N j�,� 41 "H x 36"W ..•... . • • .• .• •• • •��/1.• ....•• • • . • • • 09 �N�� MOUNTING DETAILS CHANNEL INDIVIDUAL LETTERS WITH LED (TRANSVERSAL VIEW) 0.40 Alum. return 1" 1/8" Thick clastic face I G a -- Led self supported • Attached w/3m vhb by Manufacturing suggested - System as per nec 60041 114" X 2 " TAP CONS 3 Min. Per Letter C� 1/4" Drain holes W wire conduit w/ #12 wire, thnn.Thwn. (rounded) as per nec 600.24 qround wire 20 Amps Lockable 701351 24.0 VDC power supply for up to 2.50 amps. AWG # 18,2 conductor, PVC jacketed, NEC type power limited tray cable. (PLTC) with UL Listing. Used fox letter to letter jumpers or extension of Power supply lead up to 15'. AWG #14,2 conductor, PVC jacketed, NEC type power limited tray cable (PLTC) with UL Listing. Used for extension of power supply lead up to 50'. UL Listed for wet location or NEMA 3R box, min. dimensions 12"xl2"xl6", vented (if power supply is to be mounted in a location exposed to weather). Cable tie downs (plastic with double sided tape for mounting). 4" nylon zip ties. Wire nuts (ideal P/N #30-072 blue). Sheet metal screws (#8 or #10) or rivets (1/8' or 3/16") for mounting frames. Rags or shop towels. Silicone sealant 1/2' conduct connectors for power supply primary (water tight if mounting power Supply in a box outdoors). Disconnect switch for primary power shutoff (see figure 13) Red Dot S323E, Leviton 1451-ICP or equivalent. The location of the disconnect switch after installation shall comply with Article 600.6(A) (1) of the National Electrical Code. ALL ELECTRICAL COMPONENTS ARE U.L. LISTED AS PER NEC 600.3 PRIMARY 120 VOLTS #12 WIRES BY OTHERS SIGN GROUNDED ACCORDING TO NEC 600.24 AND 600.7 CODES IN EFFECT ARE NEC 2014/FBC2017, 6TH EDITION THE LOCATION OF THE DISCONNECT SWITCH AFTER INSTALLATION SHALL COMPLY WITH ARTICLE 600.6(A) (1) OF THE NATIONAL ELECTRIC CODE EXISTING PRIMARY ELECTRICAL SOURCE (1/2' CONDUICT METAL SHOWN, WIRE #12 120 VOLTS NEC 600-6 & 600-21 NOTE: Time Clock and Photo Cell Required Block wall Transformer cane LED Transformer 20 Amps Lockable switch MOUNTING HARDWARE CHART WorL••• • • • • 011 W •. 3 MIN. PER LETTER •.••.b o 0,0 • 318" X 3" SUP-RSLEEVE 6• • • 1/4" X 3" BOLTS THRU WALL 4400 • • • • 1/4"X23/4"TAP CONS •••• • 1/4" LAG BOLTS • • • • 3/8" X 6" TOGGLE BOLTS • #10 X 2" HEX SCREWS 0• • 3/8" X 3" WOOD SCREWS • • • • PANEL SCHEDULE •••• ALL ELECTRICAL COMPONENTS ARE UL LISTED AND APPROVED ALL SIGNS GROUNDED ACCORDING TO ARTICLE 600.3 OF THE N.E.C. LaoPERPH� roruLan EASING +- TWALA Da MCELECTRIGLSERYCH olsco AI IZ FUSEngT,]S*L @ mAfO LETEROIR RROMEDEi L� PNEl q Yl N A LED SPECIFICATIONS Input Voltage 12VDC Module Level Power: 2.0 W/rt System Level Power: 2.25 W/ft IIf1�er1ARlthafS vL Underwriters Delivered Lumens: 150 Lm/ft System Efficacy: 66 Lm/W uS>ING MARK SiGN SEEN LA•E Viewing Angle: 120' SHOWN ON EACH LETTER AS PER MAWING Correlated Color Temp: 4000K ELSE WX SIGN Ho. "1( I601Gfr5) oNEeooEONE sox L70 Calculated Life: 99,000 Operating Temperature: -40 to 140'F