PLC-19-1517Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
1700 NE 105TH ST, Miami Shores, FL 33138
rnntarts
ip GAZ I fLnnljq
issue Date: 07/16/2019
Parcel Number
1122300500001
Permit NO.: PLC-07-19-1517
Permit Type: Plumbing - Commercial
Work Classification: Alteration
Permit Status: Approved
Expiration: 01/13/2020
THE SHORES CONDOMINIUM, INC. Owner MIKE DOUGLASS PLUMBING, INC. Contractor
DAVID RAY
Home: 3058936741 290 SW 12 AVE, POMPANO BEACH, FL 33069
Business: 7549999471
Mobile: 9413032002
Description: CURED IN PLACE PIPE -LINING OF MAIN UNDER Valuation: $ 77,500.00 Requests:
Inspection 305-4949
SLAB SANITARY DRAIN
Total Sq Feet: 0.00 1 1 7��]
Fees
Amount
Application Fee - Other
$50.00
CCF
$46.80
DBPR Fee
$34.88
DCA Fee
$23.25
Education Surcharge
$15.60
Permit Fee
$2,275.00
Scanning Fee
$9.00
Technology Fee
$58.13
Total:
$2,512.66
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$2,512.66
Credit Card
07/02/2019 $50.00
Check # 14409
07/16/2019 $2,462.66
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated.
Owner / Applicant / Contracto_ ram, Agent
Date
July 16, 2019 Page 2 of 2
1 I M a m I Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING
PERMIT APPLICATION
❑BUILDING ❑ ELECTRIC ❑ ROOFING
PECEIVE.D
J L .02 2019
C20)-� _�
Master Permit No. � oa - 1� 1 CJ `t
Sub Permit No.
❑ REVISION ❑ EXTENSION MRENEWA4
]PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 1700 NE 105th Street
City: Miami Shores County: Miami Dade Zia• 33138
Folio/Parcel#:11 2230 050 0000 - Common Area Is the Building Historically Designated: Yes NO X
Occppancy Type: Load: Construction. Type: _ Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): The Shores Condo Assn. Phone#: 305-893-6741
Address:1700 NE 105th Place
City: Miami Shores State: FL Zip: 33138
Tenant/Lessee Name: Phone#:
Email: theshorescondo@att.net
CONTRACTOR: Company Name: Mike Douglass Plumbing, Inc Phone#: 754-999-9471
Address: 290 SW 12th Avenue Suite #3
City: Pompano Beach State: FL Zip: 33069
Qualifier Name: David S. Ray Phone#: 941-303-2002
State Certification or Registration M CFC1430064 Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ 77,500.00 Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New 0 Repair/Replace ❑ Demolition
Description of Work: Cured in place pipe - lining of main under slab sanitary drain
Specify color off color thru tile:
Submittal Fee $ _') V ' � Permit. Fee $ CCF $ CO/CC $
Scanning Fee $ Radon Fee $ DBPR $
Technology Fee $
Structural Reviews $
(Rev1sed02/24/2014)
Tralning/Educatlon Fee $
Notary $
Double Fee $
Bond $
TOTAL FEE NOW DUE $ �TfO
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in complian>r' with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant rpust
promise In good faith that a copy of the notice of commencement and construction Ilen law brochure will be delivered to the pVrjon
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the J'no site
for the first inspection whi occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
Inspection will not be app#ed and -q reinspection fee will be charged.
Signature
0 or AGENT —,
The foregoin rument was acknowledged before me this
—dayof �w1 , 20 /7 by
TOR4V, &nrwl da who is personally known to
me Olr t�'l�teute� is
who did take an oath.
NOTARY PUBLIC:
Sign:�J�
Print:
Seal: MY COMMISMON 0 00070380
EXPIRES Much 10, W.
Signature
CONTRACTOR
The foregoing instrument was acknowledged before me this
day of r-NkA -I-L 20 (CI by
Vtd who is personally known to
me
ideeti€isation•and who did take an oath.
NOTARY PUBLIC:
r*rrr�***rrrrw*rrrrrrrr**wrr*r********w**%%*****rr*rw*r*w**w***r***w*r*r*w**w********r******wwr**w**rr**+�**w**
APPROVED BY �_-�— !' -41— Plans Examiner Zoning
Structural Review Clerli
(Rev1sed02/24/2014)
Property Search Application - Miami -Dade County Page 1 of 1
t UFFICE OF THE PROPERTY APPRAISER
l Vi
Summary Report
Property Information
Folio:
11-2230-050-0001
Property Address:
Owner
REFERENCE ONLY
Mailing Address_-
_
PA Primary Zone
4900 MULTI -FAMILY -
CONDOMINUM
Primary Land Use
0000 REFERENCE FOLIO
Beds / Baths / Half
0/0/0
Floors
0
Living Units
0
Actual Area
0 Sq.Ft
Living Area
0 Sq.Ft
Adjusted Area
0 Sq.Ft
Lot Size
0 Sq.Ft
Year Built
0
Assessment Information
Year
2018
2017
2016
Land Value
$0
$0
$0
Building Value
$0
$0
$0
XF Value
$0
......................
$0
$0
....................... m.._.......
Market Value
$0
$0
$0
Assessed Value
$0
$0
$0
Benefits Information
Benefit Type 2018 2017 2016
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
THE SHORES CONDO
JULIA D TUTTLE PB B-4
BEG 730.39FTE OF NE COR ANCO SUB
PB 53-54 TH E706.61 FT M/L SWLY
ALG BLKHD/LINE 296FT W508.61FT
Generated On : 7/2/2019
Taxable Value Information
20181
20171
2016
County
Exemption Value
$0
$0
$0
Taxable Value
$0
$0
$0
School Board
Exemption Value
$0
$0
$0
Taxable Value
$0
$0
$0
City
Exemption Value
$0
$0
$0
Taxable Value
$0
$0
$0
Regional
Exemption Value
$0
$0
$0
Taxable Value
$0
$0
$0
Sales Information
Previous Sale ' Price OR Book -Page Qualification Description
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer. asp
Version:
https://www8.miamidade.gov/Apps/PA/propertysearch/ 7/2/2019
Detail by Entity Name
Page 1 of 3
Florida Department of State
Department of State / Division of Corporations / Search Records / Detail By Document Number /
Detail by Entity Name
Florida Not For Profit Corporation
THE SHORES CONDOMINIUM, INC.
Filing Information
Document Number
707621
FEI/EIN Number
59-1095398
Date Filed
07/21/1964
State
FL
Status
ACTIVE
Last Event
AMENDMENT
Event Date Filed
06/27/2012
Event Effective Date NONE
Principal Address
1700 NORTHEAST 105TH STREET
MIAMI SHORES, FL 33138
Changed: 03/15/2019
Mailing Address
1700 NORTHEAST 105TH STREET
MIAMI SHORES, FL 33138
Changed: 03/15/2019
Reaistered Aaent Name & Address
KEYSTONE LAW FIRM PA
12865 WEST DIXIE HIGHWAY
SECOND FLOOR
NORTH MIAMI, FL 33161
Name Changed: 03/15/2019
Address Changed: 03/15/2019
Officer/Director Detail
Name & Address
Title President, Director
BENAVIDES, JORGE
1700 NORTHEAST 105TH STREET
MIAMI SHORES, FL 33138
DIVISION OF CORPORATIONS
http://search. sunbiz. org/Inquiry/CorporationSearchISearchResultDetail?inquirytype=Entity... 7/2/2019
Detail by Entity Name
Page 2 of 3
Title VP, Director
WEBER, MICHAEL
1700 NORTHEAST 105TH STREET
MIAMI SHORES, FL 33138
Title Secretary, Director
Grable, Jane
1700 NORTHEAST 105TH STREET
MIAMI SHORES, FL 33138
Title Treasurer, Director
STUBBS, PATRICIA
1700 NORTHEAST 105TH STREET
MIAMI SHORES, FL 33138
Title Director
SEPE, ELLEN
1700 NORTHEAST 105TH STREET
MIAMI SHORES, FL 33138
Annual Reports
Report Year
Filed Date
2018
04/12/2018
2018
09/10/2018
2019
03/15/2019
Document Images
03/1512019 -- ANNUAL REPORT
View image in PDF format
09110/2016 -- AMENDED ANNUAL REPORTI
View image in PDF format
04/1212018 -- ANNUAL REPOR IView
image in PDF' format
01/24r'2Q1.7=_ANNUAL REP RT I
View image in PDF Format
12/14,12016 -- AMENDED ANNUAL REPORT I
View image in PUF format
03/18/2016 ANNUAL REPORT
View image in PDF format
01/25/2015 --ANNUAL REPORT'
View image in PDF format
04i02/2014 -- ANNUAL. REPORT
View image in PDF' format
03/31 %LQ13...--_ANN-UAL KENOft1,,
View image in PDF format
06/27/2012 -- Amendment
View image in PDF format
02/09/2012 -- ANNUAL REPORT
View image in PDF format
01/27/2012 -- Rea. Agent Change
View image in PDF format
01 /19/2011 -- ANNUAL REPORT
View image in PDF format
09/27i2010 __Reg,_Agenl, Change.
View image in PDF Format
05/04/2010 --ANNUAL REPORT
View image in POF format
10/1412009 -- Reg. Agent Change
View image in PDF forrnai
06/15/2009 -- Reg. Agent Change
View image in PDF format
04130/2009 -- ANNUAL. REPORT I
View image in PUF' format
http://search. sunbiz.org/Inquiry/CorporationSearchISearchResultDetail?inquirytype=Entity... 7/2/2019
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
CONTRACTORS' REGISTRATION
IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR:
A. COPY OF QUALIFIER'S STATE LICENCES
B. ✓� COPY OF LOCAL BUSINESS TAX RECEIPT
C. COPY OF LIABILITY INSURANCE*
D. COPY OF WORKERS COMPENSATION INSURANCE*
(Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit)
IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY:
A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER
B. COPY OF LOCAL BUSINESS TAX RECEIPT
C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL
CONTRACTOR'S TAX RECEIPT.
D. COPY OF LIABILITY INSURACE*
E. COPY OF WORKERS COMPENSATION INSURANCE*
(Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit)
*YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW:
Certificate Holder:
MIAMI SHORES VILLAGE BLDG DEPT
10050 NE 2ND AVE
MIAMI SHORES, FL 33138
Certificate must specify the description of operations or contractor license number.
...........................................................................................
BUSINESS NAME: 0-It Ice- _Doue, )CyS� P1 urn b inn. Jn-C
�L� 43
BUSINESS ADDRESS: 2-qD 15 I G rr-1 ri-e-, CITY kMMrV BCI'STATE ZIP 33No
BUSINESS PHONE: ((15q ) 9C'9 ` 94 I_ FAX NUMBER ()� ) �!_FI9 - C-f 9 Z
CELL PHONE 0`'(� ) -?'='3� ���- QUALIFIER'S NAME: 1�� \Jt C� � ��-7H
QUALIFIER'S LIC NUMBER: ��i'C. ) L43 G<�) Q4
RICK SCOTT, GOVERNOR JONATHAN ZACHEM, S . ECRETARY Florida -
slop-§R&
dDFor
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION: INDUSTRY LICENSING BOARD
THE PLUMBING CONTRACTOR HERE] NAS.-CCRT IFIED UNDER THE
PROVisib-.N'S:.OF. CHAPT84 489, FLORIQA STATUTES
EXPIRATION DATE; AUGUST 31,2020
Always verify licenses online at MyFloridaLicense.com
Do not alter this document in any form.
This is your license. It, is unlawful for anyone other than the licensee to use this document.
BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT
115 S. Andrews Ave., Rm. A- 100, Ft Lauderdale, FL 33301-1895— 954-831-40007
VALID OCTOBER, 1, 2018 THROUGH ,,.SEPTEMBER 30,2019
DBA: Receipt#: 182-2-95790
MIKE DOUGLASS PLUMBING INC PLUMBING/LWN SPRNKL/(
Business Name: Business Type: (LpLTjMBING CONTRACTOR)
Owner Name: RAY, .DAVID STEVEN Business Opened:12/19/2o18
Business Location: 290 SW 3.2 AVE State1CoUnty1CGrIJRQg:CFC14 30 0 64
POMPANO BEACH Exemption'Code:
Business Phone: 954 �47�.344-;,-
Rooms EMpoy"s� ftchines Professionals
qJ
5
,':Forvendinfeusiness,-Only
Number of Machines! Vandinn Tuna!
Tax Amount
Transfer Fe
afq
rjgF
Collection Cost
Total Paid
10 �o
27.00
07 - 0,0
0.1001
27.
THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS
THIS BECOMES A TAXRECEIPT This tax is levied for the privilege of doing business within Broward County and is
non -regulatory in nature. You must most all County.. and/or Municipality, planning
WHEN VALIDATED and zoning, requirements. This --Business Tax Receipt must be transferred when
the business is sold, business name has changed or you have moved the
business location. This receipt does not indidate that the business Is legal or that
It is in compliance with -Slate or local laws and regulations.
Mailing Address:
RAY, DAVID STEVEN
6302 BRAUN STREET
ENGLEWOOD, FL 34224
2018 -2019
Receipt #02C-18-0'0001215
Paid 3.2/3.9/202a 27.00
4
41 _-
MAfi�OLE 24 TO fib" `'' ��.•, �c
Towerside Terrace
�31
210 LF +/-
' 6" CLEANOUT IN FOOT,ER'
EXPOSED DUE TO
�_ r - -y .ram"•�° •7r �� �u'Zi-1� t EROSION
1700 NE, 'th -t
-s
•� . � .410 LF+
4.- CLEAN OUT
IN WALL WITH CARPET
Tour Guide D-
2018 Google
,q..—Imagery Date: 12r13/2017 25°52'
+'l
HALL WAY RUNS DOWN
CENTER, UNITS ON
BOTH SIDES, 4", 5" 6"
AND 8" AT MANHOLE??
Google Earth
W elev -1 ft eye alt 673 ft Q
Revised: October 10t6, 2014
SPECIFICATIONS FOR INSTALLING CURED -IN -PLACE -PIPE (CIPP)
LATERAL LINING INVERSION METHOD
NOTE:
This guide specification covers
place pipe lining, including
installation, and performance
exterior piping systems.
PART 1 GENERAL
the requirements for cured -in-
applicable industry standards,
verification for interior and
This specification addresses the procedures for the
rehabilitation of pipelines and conduits, 2 to 12 in. diameter,
by the inversion installation of a resin -impregnated, scrim
reinforced flexible fabric tube into an existing conduit and
secondarily inflated through the inversion of a calibration hose
by the use of a hydrostatic head or air pressure.
1.1 REFERENCES
ASTM D543 (2006) Standard Practices for Evaluating the
Resistance of Plastics to Chemical Reagents
ASTM D638 (2010) Standard Test Method for Tensile
Properties of Plastics
ASTM D790 (2010) Flexural Properties of Unreinforced and
Reinforced Plastics and Electrical Insulating
Materials
ASTM F1216 (2009) Standard Practice for Rehabilitation of
Existing Pipelines and Conduits by the Inversion
and Curing of a Resin -Impregnated Tube
1.2 SUBMITTALS
- Inversion Installation Equipment
- CIPP Scrim Reinforced Lining Tube
- 100% Solids Epoxy Resin
- Calibration Tube
- Manufacture's Installation Instructions
- Manufacturer's Warranty
1.3 PROJECT/SITE CONDITIONS
Inspect the line with CCTV and determine the overall condition of
the pipe prior to starting the Pre -conditioning of the pipe.
Revised: October 101h 2014
SPECIFICATIONS FOR INSTALLING CURED -IN -PLACE -PIPE (CIPP)
LATERAL LINING INVERSION METHOD
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
Provide new cured -in -place -pipe (CIPP) lining for the existing
[roof drain leader piping from the roof to floor level]
[horizontal & vertical drain piping] [electrical conduit]
[process piping] [ventilation] [wastewater piping] complete and
ready for operation.
Perform the rehabilitation using a tube of one or more layers of
scrim reinforced flexible needle perforated felt, of specified
length, and a 100% solids epoxy resin with physical and chemical
properties appropriate for the application, in conformance with
ASTM F1216. Submit product data for 100% epoxy resin, Scrim
Reinforced liner materials, and Inversion installation equipment.
2.2 PIPE LINING MATERIALS
2.2.1 CIPP Lining Tube
Provide a liner tube consisting of one or more layers of scrim
reinforced flexible needle perforated felt, continuous in length
with uniform wall thickness. Overlapping sections are not allowed
in the length of the liner. Ensure that the liner tube is capable
of conforming to bends, offset joints, bells, and disfigured pipe
sections.
Provide an integrated bladder within the felt tube that is made
from Material's compatible with the felt and resin systems used
and capable of withstanding the required installation pressure.
The liner tube will consist of scrim reinforcement and needled
felt. The liner tube will be fabricated together using a butt
stitched seam sealing process with a heat welded sealing tape to
ensure airtight seal. The liner tube is to be manufactured in the
United States by Perma-Liner Industries, LLC. The liner tube will
be capable of carrying resin and withstanding installation
pressures and curing temperatures. The liner tube will be lined
on one side with a translucent impermeable chemically resistant
polyvinylchlo ride (PVC) waterproof coating. This coating will be
on the inner lateral collection lined pipe after curing is
completed. The coating will provide a smooth and seamless inner
wall.
2
Revised: October 10", 2014
SPECIFICATIONS FOR INSTALLING CURED -IN -PLACE -PIPE (CIPP)
LATERAL LINING INVERSION METHOD
The scrim reinforced / seam stitched / heat welded seam tape /
felt liner tube and resin will upon installation meet and/or
exceed minimum testing standards as required by ICC, ASTM, IAPMO
and ANSI/NSF International. All materials must have 3rd party
testing provided by independent laboratory. The materials must be
ANSI/NSF Standard-14 approved, IAPMO Certified for small diameter
pipe lining in Sewer Pipes and Vents, and must be certified by
the International Code Council for the International Plumbing
Code and the International Residential Code. The scrim reinforced
/ seam stitched / heat welded seam tape / felt liner tube and
resin must have NSF Standard 14, and ICC-ES denoted on the tube.
Materials must be manufactured in the United States of America by
Perma-Liner Industries, LLC, Clearwater, Florida USA and produce
a Scrim Reinforcement in the Needle Punched Felt Liner Tube for
stretch resistance. Non Scrim Reinforced Liner Materials Will Not
Be Accepted.
2.2.2 Resin
Provide 100% solids epoxy resin impregnated, cured tube that is
resistant to shrinkage, corrosion, oxidation, and is resistant to
abrasion from solids, grit, sand in rainwater, and is solvent
free. Use a resin with proven resistance to storm water and
ultra -violet light (sunlight) at any stage prior to installation.
Polyester or vinyl ester resins are not acceptable.
Ensure the proposed resin system does not contain silicones,
stearates,
and/or natural waxes that would adversely affect the adhesives
properties or any other chemical or physical properties of the
CIPP liner.
The resin will be a two-part, 100% solids epoxy containing no
styrene. The epoxy resin shall be formulated to have a gel (pot)
life of approximately 30 minutes with a set cure time of three
(3) hours. The epoxy shall ambient cure by internal exothermic
chemical reaction and/or heat assisted using steam or hot water.
100% Solids Epoxy Resin must be formulated in the United States
of America by Perma-Liner Industries, LLC, Clearwater, Florida
USA.
3
Revised: October 10", 2014
SPECIFICATIONS FOR INSTALLING CURED -IN -PLACE -PIPE (CIPP)
LATERAL LINING INVERSION METHOD
2.2.3 CIPP Properties
Provide CIPP with minimum chemical resistance requirements in
accordance with ASTM D543. Conduct exposure to the chemical
solutions listed in Table 1 at temperatures of up to 23.9 degrees
C 75 degrees F. Conduct this test for a minimum period of one
month. Loss result cannot exceed 20 percent of the initial
structural properties.
TABLE 1 - CHEMICAL RESISTANCE REQUIREMENTS
Chemical Solution Concentration
Percent
Tap Water (pH 6-9)
100.0
Nitric Acid
5.0
Phosphoric Acid
10.0
Sulfuric Acid
10.0
Gasoline
100.0
Vegetable Oil
100.0
Detergent or Soap
0.1
Ensure the CIPP meets the minimum structural properties listed in
Table 2 below:
TABLE 2 - CIPP INITIAL STRUCTURAL PROPERTIES - ASTM F1216 & NSF
Standard - 14
Property
Flexural Strength
Flexural Modulus
Tensile Strength
Tensile Elongation
Compressive Strength
Chemical Resistance
ASTM Test Method
ASTM D790
ASTM D790
ASTM D638
ASTM D638
ASTM D695
ASTM D543
Minimum Value
4,500 psi
250,000 psi
3,000 psi
5 psi
4,000
<20% loss
Leakage Test* NSF Standard 14 0/gal/day
* Leakage test performed by ANSI/NSF International
All final test results are to be performed by an A2LA accredited
laboratory.
Manufacturer must have United States based manufacturing
headquarters. The manufacturer must have at least 15 years of
manufacturing / supplying C.I.P.P. Air Inversion Liner Tube and
Materials in the United States. The manufacturing plant must have
a Quality Assurance / Quality Control program in place and
overseen by NSF International and IAPMO R&T Laboratories.
4
Revised: October 10'h, 2014
SPECIFICATIONS FOR INSTALLING CURED -IN -PLACE -PIPE (CIPP)
LATERAL LINING INVERSION METHOD
PART 3 EXECUTION
3.1 INSTALLATION
Provide installation of CIPP system, including materials, workmanship,
fabrication, assembly, erection, examination, and inspection.
3.1.1 General
NOTE: Use the first paragraph for roof drains only.
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
[Inform the Contracting Officer of temporary roof drain flow stoppage]
For access at the bottom of the pipe sections, remove pipe sections
near the floor at the appropriate point on the vertical rain leader in
accordance with the design drawings.
3.1.2 Deviations
Should pre -installation inspection reveal conditions in the rain leader
to be substantially different than those used in the design of wall
thickness, liner tube construction, liner tube length, or resin system;
notify the Contracting Officer and provide a videotape recording of
existing conditions and design data. Do not proceed without direction
from Contracting Officer.
3.1.3 Pipe Preparation
Perform pre -conditioning of the pipe section, including preparatory
cleaning, corrosion removal, removal of grease buildup, or any other
obstruction that may interfere with lining operations. Leave
obstructions that are less than 15 percent of the pipe diameter, that
can not be removed from the pipe, in place and line over. CCTV inspect
the line immediately prior to lining and after the cleaning is complete
to ensure that the pipe is ready for lining.
3.1.4 CIPP Installation Procedure
3.1.4.1 Wet Out
Accurately calculate and measure the amount of resin and catalyst
required. Thoroughly mix the resin and catalyst. Thoroughly
saturate/impregnate the flexible felt tube with the pre -calculated
amount of epoxy resin prior to installation. Handle the resin
impregnated flexible tube to retard or prevent resin setting until it
is ready for insertion.
3.1.4.2 Insertion
Install the liner/bladder system using the Inversion method. Invert the
liner/bladder system to the specified location in the pipe. Inflate the
bladder using compressed air to a pressure adequate to form the liner
to tightly fit the internal circumference of the pipe and to cause the
resin to migrate into pipe joints, voids and defects.
L1
Revised: October 10", 2014
SPECIFICATIONS FOR INSTALLING CURED -IN -PLACE -PIPE (CIPP)
LATERAL LINING INVERSION METHOD
Install the liner at minimum low pressure.
3.1.4.3 Curing
Inflate the bladder using compressed air and leave the liner in place
until the resin curing cycle is complete. Curing occurs at ambient
temperature within three hours and one and half hours using steam.
When the curing process is complete, release the pressure and pull out
the inflation bladder. Ensure the cured composite liner remains in
place within the host pipe and provides a smooth bore interior that
conforms to the existing pipe [eliminating rain water leakage]. Ensure
the tube is continuous in length, wall thickness, and is uniform.
3.1.4.4 Service Connections / Reinstatements
All CIPP lined over branch pipeline connections, tye-ins, drain pipe
connections, and vents must be opened using a robotic reinstatement
cutter. The cutter must be able to provide video relay of the
reinstatement cutting operation from start to finish. The reinstatement
of all branch pipelines must be conducted from the inside of the lined
pipe or from inside the branch line. The branch pipe opening connection
must be cut to allow 100% flow from the branch pipelines. The
reinstatement robotic cutting must be completed by using Reinstatement
Equipment supplied by Perma-Liner Industries, LLC, Clearwater, Florida
USA. Only equipment supplied by Perma-Liner Industries, LLC will be
accepted.
3.1.4.5 Finish
Do not leave in the host pipe, any barriers, coatings, or any material
other than the cured liner tube/resin composite, specifically designed
for desirable physical and chemical resistance properties. Remove any
materials used in the installation, other than the cured liner
tube/resin composite. Remove any cured liner tube/resin composite pipe
left protruding from the service connection. Ensure that the finished
CIPP is continuous and free from visual defects such as foreign
inclusions, dry spots, pinholes, and delimitation.
3.1.5 Liner Inspection
Perform a final Closed -Circuit Television (CCTV) inspection to verify
proper cure and integrity of the composite liner.
3.2 FIELD QUALITY CONTROL
Test system in accordance with ASTM F1216 and NSF Standard 14, as
supplemented and modified by CIPP manufacturer's written installation
instructions.
6
Revised: October 10", 2014
SPECIFICATIONS FOR INSTALLING CURED -IN -PLACE -PIPE (CIPP)
LATERAL LINING INVERSION METHOD
Upon completion, submit the DVD records of pre -lining inspection and
post -lining inspection, along with the written report summarizing the
extent of pipe lining performed. Update pipe lining contract record
drawings to reflect the as -built condition after lining is complete and
submit to the Contracting Officer. The Contracting Officer may review
the video and documentation, and may inspect the work site to determine
that the scope of work is complete, that the work is satisfactory, and
the site has been returned to its original condition.
3.3 ADJUSTING AND CLEANING
After liner installation has been completed and accepted, clean the
entire project area and restore the site to its original condition
prior to the commencement of work. Dispose of all excess material and
debris not incorporated into the permanent installation.
-- End of Section --
The Shores Condo, 1700 NE 105 Street, Miami Shores FL
PROJECT PROPOSAL
The Shores Condo
1700 NE 105th Street
Miami Shores FL 33138
December 11, 2018
305 893 6741
thesho rescondo@aft. NET
Reference: Cleaning and Lining of Main Drain Line Proposal REVISION 1
Mike Douglass Trenchless Technologies (MDTT) proposes to video inspect, hydro jet or mechanically clean and
install "Cured in Place Pipe" (CIPP) lining via "Pull in Place" or "Inversion" method in the building on the property
described above in the main horizontal sanitary drain lines. A video was performed on 12/6/2018 of the main drain
lines, see attached inspection report.
Pipe layout, dimension changes within the pipe, and pipe / equipment length will determine access points. Access
points become necessary for liner installation. At least 4 holes will be required, two in the carpeted hall floors and 2
in the tiled elevator lobby first floor and will be opened by MDTT to be finished by others. Protection will be
provided in work areas, however dirt will be exposed, sanitary lines will be opened, and water will be used in the
cleaning process. Areas of any additional access holes, if necessary, will be discussed with management prior to
opening. Access to units may be required, toilets may need to be lifted but would be reinstalled by MDTT after work
in that area is completed. NO 2" pipes are included in this bid. UP to 20 reinstatements of laterals are included in
this bid.
MDTT will supply labor and materials required to complete the work per the above specifications for a
Total Fee of $79,000.00
Less Paid Video Fee ($1500.00)
Contract Balance $77,500.00
Notes: Job duration is expected to take approx. 3 weeks for cleaning and PIP installation. The water will be turned off in the building from
approx. 8 am to approx. 5 pm. while workers are present. Any unforeseen circumstances will be addressed before work is preformed and
approved in writing by both parties.
Terms: 10 PERCENT DEPOSIT, BALANCE TO BE PAID IN FULL ON COMPLETION
PER SCHEDULE OF VALUES
Respectfully submitted,
pau.L L uca-k
MDTT Representative
Mobile 941 223 3632
Office 877 426 8660
www.pipeliningmd.com.
paul@mdtrenchless.com
CFC 1430064
Permit costs and engineering fees, if any, would be added to this proposal.
1
The Shores Condo, 1700 NE 105 Street, Miami Shores FL
PIPE RESTORATION:
Inspection
Mike Douglass Trenchless Technologies uses State -of -the -Art Video Inspection Equipment to locate exactly
what and where the problem is. Our range of the high-tech proprietary equipment can investigate Sewer Piping,
Storm Piping, Water Piping, Mechanical Piping and any other piping as narrow as 3" inches in diameter. With
Mike Douglass Trenchless Technologies' sophisticated inspection and testing equipment, plumbing
configuration breakdown methods and engineering and insurance reporting capabilities — valves, fittings,
cracks, intrusion, leaks, faults and other failures can be detected painlessly. Mike Douglass Trenchless
Technologies will also provide a professional opinion as to the usable life span of the existing system.
Mike Douglass Trenchless Technologies will internally inspect the designated piping system using CCTV
Cameras to evaluate and map piping for restoration. The CCTV inspection camera will be moved through the
line in either direction to allow adequate evaluation by the technician, stopping when necessary to insure proper
video recording of the condition and configuration.
Cleaning
Mike Douglass Trenchless Technologies has an extensive amount of experience in the restoration of sanitary
systems in buildings that have aging cast iron pipe. These pipes become brittle due to deterioration caused by
corrosion, scale and build up. After our cleaning process, the serviced plumbing pipes will return to their
relative, original operating diameter. We will remove the debris from the pipeline with either mechanical or
hydro -jetting technology as best fits the pipe condition and configuration. This careful process utilizes differing
PSI levels to ensure the integrity of the pipe is not compromised. The pipeline shall be inspected with CCTV
camera equipment before, during and after the cleaning process.. Waste material and debris will be removed
and disposed of in accordance with the appropriate regulatory agency requirements and not just washed down
line. Mike Douglass Trenchless Technologies will provide DVD documentation of the finished product to the
owner or owner's representative. Mike Douglass Trenchless Technologies will immediately notify the
appropriate person if problems are discovered during the cleaning process that would create further damage if
cleaning is attempted or continued.
Safe and Durable —The epoxy is UL certified safe to NSF/ANSI Standard 61. The epoxy was developed and
patented by the U.S. Navy and has been successfully installed by Mike Douglass Trenchless Technologies'
technicians since the 2006 for, commercial, industrial and other applications. Testing engineers estimate the life
expectancy of the epoxy is roughly 50 years. The liner is tested and approved as a "structural, , stand alone" pipe
when fully cured.
Cost Effective — Pipe lining is as much as 45 percent less expensive than traditional pipe replacement costs such
as re -piping. Lining is a non-invasive process, so there is no destruction to buildings, hardscape or landscape.
Reconstruction costs for re -piping are as much as 60 percent of direct pipe repair costs and epoxy lining eliminates
the need for reconstruction.
Minimal Downtime — The epoxy lining process takes a fraction of the time of traditional re -pipe methods.
Minimal Disruption and No Occupant Displacement — Mike Douglass Trenchless Technologies' pipe restoration
process is quick, quiet, non-invasive and requires no displacement of a building's occupants. When needed,
temporary bypass water systems are quickly installed to provide uninterrupted water service so that occupants,
businesses and clientele may continue business as usual in an undisturbed environment.
Versatility in Application — Epoxy lining can be performed in virtually any pipe in any building, structure or environment,
above or below ground. Lining has been installed by Mike Douglass Trenchless Technologies' technicians in tte piping
systems for hotels, high-rise condominiums, hospitals, restaurants, airports, schools, museums and many other
applications.
Page 2 14 Accepted 4 W
x !J
The Shores Condo, 1700 NE 105 Street, Miami Shores FL
REFERENCED STANDARDS:
IAPMO C-4547: Cured in Place, Thermosetting Resin Conduit Liner
ANSI/NSF 14: Plastic Piping Systems Components and Related Materials
ASTM D543 — 06: Standard Practices for Evaluating the Resistance of Plastics to Chemical Reagents chemical reagent,
dimensional changes, exposure, mechanical property changes, plastics, stress
ASTM D638: Standard Test Method for Tensile Properties of Plastics modulus of elasticity, percent elongation, plastics,
tensile properties, tensile strength s ratio, transverse strain, Engineering criteria/design, Reinforced plastics, Tensile
properties
ASTM D790 A: Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical
Insulating Materials
ASTM DF1216: Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a
Resin -Impregnated Tube Resin -impregnated tube, Resins, Sewer pipe (thermoplastic), Thermosetting plastic
pipeAuWng/fittings, Steel pipe
ASTM D1743 A & B: Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled in -Place Installation
of Cured -in -Place thermosetting Resin Pipe (CIPP)
ASTM D2990-01: Standard Test Methods for Tensile, Compressive and Flexural Creep & Creep Rupture of Plastic
PERFORMANCE:
Mike Douglass Trenchless Technologies shall provide the owner with a written Manufacturer's'"
Warranty to be in force and effect for a period of 10 years from the date of completion for CI PP
Structural Rehabilitation. The warranty shall require provider to repair or replace the liner should failure
or damage result from faulty materials and a 10 year warranty on our workmanship.
INSURANCE & SURETY:
Mike Douglass Trenchless Technologies will provide submittals to the following insurance coverage;
• Workmen's Compensation & Occupational Disease Act
• Excess Umbrella Liability
• Comprehensive General Liability
• Commercial Automobile Insurance
Mike Douglass Trenchless Technologies conforms to Florida State Performance Bonding Guidelines and
all applicable OSHA safety standards and participates in Florida's "Drug Free" work -place program.
CHANGES IN WORK:
Contractor shall not request changes in the Work unless so required and approved in writing by the Principal, Owner or
Owner Representative through a Change Order
CUSTOMER PROVISIONS:
Free and clear access must be provided to access points throughout the duration of the project. Although it is owr
sincerest desire to keep resident disruption to a minimum, certain drainage pipes may be required to be shut down for
periods of time throughout the process. Mike Douglass Trenchless Technologies will make every effort to ensure that drain
service resumes at the earliest possible time. It is the responsibility of management to notify inhabitants of service ,.
disruptions. Mike Douglass Trenchless Technologies will inform management of schedule changes in a timely manner as
possible. Customer agrees to indemnify Mike Douglass Trenchless Technologies from any direct and or collateral damage
arising from failing plumbing, latent defects, unforeseen conditions & events in relation to customers plumbing. It is the
responsibility of the management to ensure that the pipes being serviced are not used during the procedure unless
otherwise notified by project manager. Mike Douglass Trenchless Technologies will not be held responsible for back-ups
caused by excessive flow from individual units, or inhabitants.
P a g e 3 14 Accepted "T
L
O
The Shores Condo, 1700 NE 105 Street, Miami Shores FL
SCOPE OF WORK:
Mike Douglass Trenchless Technologies proposes to CCTV inspect, restoratively clean and CIPP line the 4", 5"
6", and 10" horizontal main drain. NOTE: 2" pipes are not included in this bid.
1. Mike Douglass Trenchless Technologies will remove all debris that is loosened from
the piping and dispose of properly.
2. The work will take place during normal hours as 8 am until 5 pm
3. It is estimated that it will take 3 weeks for full site completion.
4. The proposal amount is for $77,500.00 with paid camera fee.
ALL PERMITS — ENGINEERING FEES ARE IN ADDTION TO THE PROPOSED QUOTE
r
Terms: 10 PERCENT DEPOSIT, BALANCE PER SCHEDULE OF VALUES.
ACCEPTANCE OF PROPOSAL AND AUTHORIZATION TO PROCEED
The above proposal represents the entire understanding between both parties. No prior verbal or written
agreements shall have any force of effect. Mike Douglass Trenchless Technologies is authorized to
proceed with a formal contract as described and payment is hereby guaranteed as noted above.
Date: �J, 2 3 — I
Total Amount Authorized: 7 7, 5 0 d ' G
Authorized Signature: �T
Printed Name: /1-4 1 c- k 0 e,/ aj e, k 6 &
Title: Ci , If
4UW111 . o �t
MMUUMUNAL �ra.x�w.rawarwi.ww
sls�asrdsWorkhvk*
P age 4 14 Accepted f�16✓
M
revised 4/9/2019 Mike Douglass Trenchless Technologies
Horizontal Drain Cleaning and Relining
The Shores Condo 305 893 6741
1700 NE 105th Street theshorescondo@att.NET
Miami Shores FL 33138
Total Contract $77,500
Deposit $7,750
Balance to be paid on completion of each wing
South wing
East wing
North wing
Retention until permits are closed
Accepted AIL(
$23,250
$23,250
$15,500
$7,750
$77,500
Dated 3 - j
r Jill
I:iAHHOLE 24 TO 30"
. �, �T�r .ae•' �m'�.'.'?ee' r 140,L( 10 LF -;
v
r �3
. -i► r 7.-;ram.- �' - '7i "�-= ,--�"-�'
�..
._No11c. L j
f-
TcurGuide rGl' S_. Ir-V" n a
CLEAN OU-T
IN WALL WITH CARPET
r 29 i$ 000'3;�
Date:12/13/2017 25-52'
5
t7
2r
Ai,
6" CLFANOUT IN FOOT,ER
EXPOSED DUE TO
EROSION
HALL WAY RUNS DOWN
CENTER, UNITS ON
BOTH SIDES, 4", 5" 6"
AND 8" AT MANHOLE??
Google Earth
W elev -1 ft eye dt 673 t