Loading...
FW-19-1879Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 r� I Issue Date: Location Address Parcel Number 98 NE 103RD ST, Miami Shores, FL 33138 1132060131570 Contacts Permit NO.: FW-08-19-1879 Permit Type: Fence/Wall Work Classification: Wood Fence Permit Status: Approved Expiration: 05/19/2020 Gonzalo Rey Owner HOME OWNER Contractor 98 NE 103 ST HOME OWNER Business: 3054940922 gonzalorey73@hotmail.com Description: NEW WOOD FENCE 6 FT HIGH Valuation: $ 753.00 on Requests: Inspection titi4949 Total Sq Feet: 712.00 Fees Amount Application Fee - Other $50.00 CCF $0.60 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.20 Planning and Zoning Review Fee $35.00 Scanning Fee $9.00 Technology Fee $2.50 Wire and Wood Fence Fee $50.00 Total: $151.30 Building Department Copy Payments Date Paid Amt Paid Total Fees $151.30 Credit Card 11/21/2019 $151.30 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date November 21, 2019 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECFIVEG �151VLqCL (-A FBC 20[� BUILDING Master Permit No. ]W S Jq- T 1 PERMIT APPLICATION Sub Permit No. CtN -36 19 --1 1 BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [—]RENEWAL ❑ PLUMBING ❑ MECHANICAL [—]PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: qt City: Miami Shores County: Miami Dade Zip: 331} Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: !&Xe Flood Zone: BFE: FIFE: OWNER: Name (Fee Simple Titleholder): QAML Q ,4 Ph Address: W AwW of 02 S� City: State: Tenant/Lessee Name: Email: 1�0-PA6 Lt94-_0C12' Zip: one#:� CONTRACTOR: Company Name: C114�1'1&2— Phone#: Address: City Zip: Qualifier Name: Phone#: > State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: ne#: Address: _ City: State: Zip: .7s Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: ❑ Additii'on El Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: /'j("L0 WoA f=uC oe 4T A a Specify color of color thru tile: Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ ( 3 O (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. v "WARNING`10O OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUk LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an esti fnated value excgeding $2500, the applicant must promise in good faith that a copy of the notice of,commencement and construction lien law brochure will be delivered to the person whose property, iSsubject to attachment. Also, a cer i-?`04cd'py of the recorded notice of commenc6iienfmust be posted atlthe job site for., the•sfirst inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. , Signature Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this Me day of i'I Y 7 20 , by >t2 1�_Who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: �����\` SILVER �c ...: Sign: Print: ; coti r6' 20 The foregoing instrument was acknowledged before me this day of , 20 , by who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: e! Print: as Seal: �g54�6o �� o` Seal: ***************�**�************* `*>R�:��l�lrl 1kr***r***rr*****■r*******r*******r*r*********�****��******r•** 'rrfi!ltl4+%' APPROVED BY li Gl Plans Examiner ��\\1�\� Zoning Structural Review Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMENT NAME:(4iaLQQLQDATE: 0� —/ klq ADDRESS:M Jc P3 w t !mil /�1_�_\ Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. � Initial 2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. 1 understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial 4. 1 understand that I may build or improve a one family or two-family residence orra farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption. _'o Initial 5. 1 understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. Initial 6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial �� ..l 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance"Contrjbutions Act (FICA) and must provide workers` compensation for the employee.'I understand that my failure to follow these may subject to serious financial risk. r Initial• 9. 1 agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govern owner -builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial_ 10. 1 understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.mvfloridalicense.com/dbpr/pro/cilb/index.htmI Initial_ 11. 1 am aware of, and consent to; an owner -builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: _l 4 �► � o S'' � Initial_ 12. 1 agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that I have provided on this disclosure. t Initialer Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual 9r firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a Ijiensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this $6 day of 09 , 20 By �� — who was personally known to me or who has Prndurpd thprp I irpncp nr Cation •�4 NOT Ire it ❑ Shadow Box W Vertical Picket Board on Board Fence Good Side Out. The vertical and horizontal supporting members of a fence shall face the interior of the plot on which the fence is located and the finished side shall face the adjoining lot or any abutting right- of-way. r • w •Y• w •0 • ��QCS • • • • • • • • K J\ • • • V. R • • • • • •• • r• • • • ••• Miami Shores Village re ••; :w: 00 :• Building Department •' ..R •• 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 WOOD FENCE DETAIL Fences < = 6' high posts spaced at 4' on center maximum Fences < = 5' high posts spaced at 5' on center maximum Fences < = 4' high posts spaced at 6' on center maximum Fence must not exceed 6' in height 4x4 pressure treated ., posts embedded 2' into concrete footing 10" diameter x 2'deep ALL wood must be pressure treated All fasteners must be corrosion resistant No less than two fasteners in any connection Revised 10/14/2016AS 1 x pickets fastened with two corrosion resistant fasteners per connection 2x4 horizontal pressure treated wood members with two corrosion resistant fasteners per connection JOHN IBARRA & ASSOCIATES, INC Professional Land Surveyors & Mappers • . ... . . . •-.. M4i'iN�SLAR AAw`+?-iS^�`iV �t�JFf��t:C9M 777 N.W 72nd O.V 6241!2 • • • • a8R4 VEL PRA SOUTH SUITE 3025 : : •: SLejTE 0 MIAMI, FLOR!DA 331 -035 • • • • • • Ctv PH: (305)262-0400 1 9) 6 FAX: (305) 262-0401 1 1p TQ F WAY BY DA R t STREET F MAP OF BOUNDARY SURVEY 98 NE 103rd STREET, MIAMI SHORES, FL 33138 GRAPHIC SCALE LEGAL DESCRIPTION: -20 0 10 20 LOTS 1 AND 2, BLOCK 12, OF AMENDED PLAT OF MIAMI SHORES SECTION No. 1, ACCORDING TO THE PLAT THEREOF AS RECORDED /N PLAT BOOK 10, PAGE 70, (IN FEE)9 OF THE PUBLIC RECORDS OF — —I INCH = 20 FEET MIAMI-DADE COUNTY, FLORIDA. ABBREM77ONS AND MEANINGS PpROVED \O - •• • • • • • ••• •• U'? R=25 00' 7"__IGALL r CF.Pl r FCT TO CUt•1PL"N° I CONC. = „nl�?I II F44 r�1rJ � ^I•II 1T''°=_RE(11RN 50 ;00' ww.M. T=24.85' I CH=35.25' I t1=89°39'20" \� F I. R. 112' NO CAP 30.00' vNW CORNER r//'� NO CAP °pI \� v \ f f OF LOT-3 f-1 i 89. 0.30' CBW / `.. i \ ✓ F.I.P. 112" -- NO CAP- C; A5PHALT SWK. 0.20' ; DRIVEWAY °�� ENCR. F.N.D. - NO ID. 30.00' CERTIFICATION: 2.50'CBVt GONZALO REY $ — 14./+G, - - U.P. INAKI SA/ZARBITORIA, ESQ., P.A W! j OLD REPUBLIC NATIONAL TITLE 2.50' CBW , ' F '1 INSURANCE COMPANY \a' 1 .P g' i CBW VANDYK MORTGAGE w `� I PLANTER 0.45' CL 1 CORPORATION, ITS SUCCESSORS z 19 16' } AND OR ASSIGNS, AS THEIR z ' 0- I 3 = INTEREST MAY APPEAR lu' I i3 4� 111 O Z - _ N ttt J ONE STORY 0 _c) t �� i ci ! RES. # 98 II �q ° LU Lam" _ A—t✓• I T ! O I ' l 3LOCK 2 i 28.ss' 3� OCK - 12 _ I W i 3 ,k Z 2.80' CBW \ �; D_ _ ' ENCROACH ENT NOTES: i ur N I A NORTH SIDE OF THE SUBJECT PROPERTY, 1! CARPORT Lr, 0,47• ! N I CONCRETE RETURNS ARE ENCROACHING N INTO THE RIGHT OF WAY OF NE 103rd i A.0 ±44' ASPHALT K� "' � �' L=39.12' I PVMT. (A 1''I 8.35' PWY (A) RETURN F.N.D. 5` CONC. 5WK 105.43' 5L:P. r NO ID. STREET. B. EAST SIDE OF THE SUBJECT PROPERTY, i / it �\ J 2 3 S' 2r. 1 4' CONCRETE SIDEWALK IS ENCROACHING I i 28.95' INTO THE SUBJECT PROPERTY. 21.18' ` j C. SOUTH SIDE OF THE SUBJECT PROPERTY, WOOD GATE AND CONCRETE RETURN ARE i CONE. SLAB LI =' - At J�— � CONC. STEPS 1! i ENCROACHING INTO THE ALLEY. CONC i"-�; TILE (7 3, o�— OVERHEAD 8y. Rs�,, END OF WIRE � I 3 it CONC. SWKA — I PLANTER 4..50' V✓DOD ` 2.80' CBW I R NO CAP' 1 /2" GATE 30.00' -� j� NO CAP — 2.80' CBW - -- — ----- — — 105.51 CBW 0.40 CL (E) I SWK. a� 0. 15' CBW 0.05' CL (W) J g' ASPHALT (C) CBW 0.60' CL(S) k W.V. ENCR. CBW 0.15' CL (S) INN. PVMT. 15' ALLEY (N.A.P.) -- - -- - - - - - - - - - -- - U.P. U.P TIk C4e A - ARC A'C = AIR CONDRNIIPR PAD. A.E.- ANCHOR BABEMENT. AIR - AWMNIM ROOF A5 = ALUMINUM SHED ASFII = A5RHALT B.L.= BLOCK OMER. B.L.R.= 5ROWARD COUNT`.' RECORDS BLDG. = BUI DNG. B.M.- BENCH MARK B.O.B.- BA515 OF DFAPJNG5. C - CALCULATED C.5 = CATCH BASIN. C.B.5 = CONCRETE BLOCK STRUCTURE. CBW = CONCRETE BLOCK WALL CH.=CHO. CH.B.= CHRDORD BEAwNG. CL - CLEAR C.L.F.= CHAIN UNK FENCE. CM.E= CAN& MAINTENANCE EASEMENTS. CONC. CONCRETE. C.F.= CONE. PORCH. CS.= CONCRETE SLAB. C.UP-= CONIC. UTILITY POLE C.W.= CONCRETE WALK D.E.= MANAGE EA5EMENT. D.M.E= DRAINAGE MAIMQLWCE EASEMENTS DRIVE = DRIVEWAY . DEGREES. E - EAST. EB - ELECTRIC BON E.T.P = ELECTRIC TRAN5FCRM[R PAD. ERN.= ELEVATION. P.H.= FIRE HYDRANT. F.I.P.= FOUND "pin. F.I.R.= FOUND I<ON ROD, F.F.E.= RN15HfD FLOOR CINATION. F.N.O.= FOUND NAILa DISK fR - FRAME. fT - FEET. FNIP.- FEDERAL NATIONAL IN5URANCE F.N.= FOUND NAIL H.- HIGH BIC&M I.F.- IRON FENCE IN.t EG= INGRE55 AND EGRT55 EASEMENT. LB. = C rbf— I A"I1� LB.078% LP.= LIGHT FOIE. LF.E- LOWEE_iT FLOOR ELEVATION. L.M.E.= LAKE MAINTENANCE EASEMENT. MNUTE5. AL - AGAURED 015TANCE. MB = MAIL BOR M.0 CA.- MIAMI DADE COUNTY RECORD5 M.E.- MAINTENANCE EASEMENTS MOH. = MONUMENT UNE. MH - MAMMOLE MA - MONUMENT UNE. NAP. = NOT A PART Of. NGVD = NATIONAL GEODETIC VERTICAL DATUM. N. = NOP.TH. N.T.5. - NOT TO SCALE. .NO. = NIIIABER 05 - OFFSET O.H. = OVERHEAD O.H.L= OVERHEAD UTILITY UNE5 O.R.B. = OPPICIAL UMKO5 BOOK OVH - OVERHANG PVMT.= PAVEMENT. PL.- PLANTER. Fn = FROPEM UNE. P.C.C.= POINT OF COMPOUND CURVE. P C.= POINT OF CURVE. PT.- FONT OF TANGENCY. FOC.- POINT OF COMMENCEMENT, FOB.= POINT OF BEGINNING. F.ILC- PONT OfREVERE CURVE P.B.= PUT BOOK PG.- PAGE PWY - PARKWAY FRM. = PERMANENT REFERENCE MONUMENT. P.L5.= PROFE5510NPL LAND 5URVEAK R - RECORDED DISTANCE RR- RAIL ROAD. RE5.= RESIDENCE. PROF. LOR.- PROPER CORNER RAM - RIGHT-OF-WAY. RP.= RADRI5 POINT KGL_ RANGE. SEC.= SECTION. STY = STORY. 5WT . 51DENA K. 5J1.= SET !RON PIPE LB.: 8M- S.P. - 5CREENED PORCH 5.- SOUTH. 5ECOND5 T _ TANGENT TB _ TELEPHONE BOOM T U E.= TECHNOLOGY UTIUT! EA5E D' T58 = TRAFFIC BIGNAL BOX TSPOL .P. - TRAFFIC SIGNAL E TIM. = TOWNSHIP, UTLL._ UTILITY. U.P - UTILITY POLE. W.M.= WATER METER W P.- WOOD FL'NCE. WJ .= WOOD ROOF. W.M.= WATER METH W.F.= WOOD FENCE. W.R= WOOD ROOF. W5.= w000 SHED. W - WE5T ry - CENTER UNE. 0 = CENTRAL ANGLE. $ = ANGLE. OVERHEAD UnUTY LINTS --------- - CONCRETE BLOCK WALL CHAIN .INK FENCE - IRON FENCE ^If B wow PENCE BUILDING SETBACK UNE UTILITY EASEMENT ,N--r"r-- - UMITED ACCE55 RW NON -VEHICULAR Al:CE55 AW .000 . 805TING ELEVATIONS N= I 2,o S, MnNr Jr-� LOCATION SKETCH SCALE =N.T.S. LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY: • THERE MAY BE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY. • THE PURP05E OF TH15 SURVEY 15 FOR USE IN DETAINING TITLE INSURANCE AND FINANCING AND SHOULD NOT BE USED FOR CONSTRUCTION PURP05E5. • EYAMINATION5 OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFECTING THE PROPERTY. • THIS SURVEY 15 SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EA5EMENT5 OF RECORD. • LEGAL DE5CRIF7ION3 PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY. • BOUNDARY SURVEY MEANS A DRAWING AND/ OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN THE FIELD, COULD BE DRAWN AT A SHOWN SCALE AND/OR NOT TO SCALE; THE WALLS OR FENCES MAY BE EXAGGERATED FOR CLARITY PURPOSES. EASEMENTS AS SHOWN ARE PER PLAT BOOK, UNLESS DEPICTED OTHERWISE. • THE TERM 'ENCROACHMENP MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS. • ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS, 5ETBACr5 AND WILL BE RE5PON9BLE-F0R-5UBMI7TING - • PLOT PLANS WITH CORRECT INFORMATION FOR 'APPROVAL f`OR AUTHORIZATION' TO THE PROPER AUTHORITIES IN NEW CONSTRUCTION. • UNLESS OTHERWISE NOTED, TM15 FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING AND/OR FOUNDATIONS. • FENCE OWNERSHIP NOT DETERMINED. • TH15 PLAN OF SURVEY, HAS BEEN PREPARED FOR THE EXCLU51VE USE OF THE ENTITIES NAMED HEREON, THE CERTIFICATE • DOES NOT EXTEND TO ANY UNNAMED PARTY FLOOD ZONE INFORMATION. - THE NFIP FLOOD MAPS HA VEDESIGNA TED THEHEREINDESCRIBED LAND TO BE SITUATED IN- FLOODZONE' x' BASEFLOODELEVA770N.- NIA. COMMUNITY.f20662 PANEL' 0302 SUFFIX L DA 7E OF FIRM 09/f1/2009 THE SUB✓ECTPROPER TYDOES NOTLIEINA SPECIAL FLOOD HAZARD AREA. SURVEYOR'S NOTES: I. IF SHOWN, BEARINGS ARE REFERRED TO AN ASSUMED MERIDIAN, BY 5A10 PLAT IN THE DESCRIPTION OF THE PROPERTY, IF NOT, BEARING5 ARE THEN REFERRED TO COUNTY, rOWNSHIP MAPS. 2. THE CLOSURE IN THE BOUNDARY SURVEY 15 ABOVE 1:7500 FT. 3. CERTIFICATE OF AUTHORIZATION LB 0 750G. SURVEYORS CER77FICA77ON. 1 HEREBY CERTIFY. THIS 'BOUNDARY SURVEY' OF THE PROPERTY DE5CRJBE0 HEREON, HAS RECENTLY BEEN SURVEYED AND DRAWN UNDER MY SUPERVISION, AND COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS AS SET FORTH BY THE FLORIDA BOARD OF PROFE55IONAL LAND SURVEYORS IN CHAPTER 5J-17, FLORIDA ADMINISTRATIVE CODE PURSUANT TO 472.027, FLORIDA 57ATUTE5 BY, 0711612015 CARLOS IBARRA (DATE OF FIELD WORK) PROFESSIONAL LAND SURVEYOR NO.: 6770 STATE OF FLORIDA (NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL PA15ED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER). REVISED ON: REVISED ON: DRAWN BY: NGH S IBgR Q �ySIFI3'q_ G� FIELD DATE: 0711612015 a NO. 6770 O `' �_n STATE OF SURVEY NO: 15-002827-1 �s NqC LAB SHEET: 1 OF 1 L.B.# 7806 SEAL