Loading...
BPP-19-1220Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address 1421 NE 104TH ST, Miami Shores, FL 33138 Contacts Permit NO.: BPP-05-19-1220 fti- Permit Type: Pools/Whirlpools/Hot Tubs a.� Work Classification: New Permit Status: Approved Issue Date: 07/24/2019 1 Expiration: 01/20/2020 Parcel Number 1122320320060 Henry Dow Owner FLORIDA POOL PATIO CORP Contractor 1421 104 CLAUDIO SEBASTIAN VALERO 12241 SW 99 ST, MIAMI, FL 33186 Business: 3058150181 Description: NEW SWIMMING POOL AND SPA Valuation: $ 24,000.00 Inspection Requests: Total Scl Feet: 465.00 Fees Amount Application Fee - Other $200.00 CCF $14.40 Certificte of Completion for Single Fam $50.00 and Duplex DBPR Fee $10.80 DCA Fee $7.20 Education Surcharge $4.80 Permit Fee $520.00 Planning and Zoning Review Fee $35.00 Scanning Fee $15.00 Structural Review ($90) $90.00 Structural Review ($90) $90.00 Technology Fee $18.00 Total $1,055.20 Building Department Copy Payments Date Paid Amt Paid Total Fees $1,055.20 Credit Card 05/29/2019 $200.00 Check # 9014 07/24/2019 $855.20 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent July 24, 2019 Date Page 2 of 2 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED MA 2 9 2019 BY: FBC 20 (� _ � 22� Master Permit No �?P- ds- 1� Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [-]RENEWAL ❑PLUMBING ❑ MECHANICAL [_]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS:) `-I Z I N i Q-1 City Miami Shores County: Miami Dade zip:33i_�O Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: 1 Construction Type: Flood Zone: BF�E,:�, / r / FFE: / `/ OWNER: Name (Fee Simple Titleholder): I 1 n✓i / .t') W Phone#: _6/ " ` 15- Z[� Y Address: ILI2iI N100 City: M ,rj rA , sb_r .5 � a State: �L Zip: 331� Tenant/Lessee Name: Email: r(� iv-Lf Poo CONTRACTO/R�Co�mpany Name: Address: City: 1 _ 1,1 Qualifier Name: 9 ne#: 3 Sys-oi-F, Zip: Phone#: State Certification or Registration #: C_T v Certificate of Competency #: DESIGNER: Architect/Engineer: to ne#: Address: City: State: Zip: Value Value of Work for this Permit: $ • �V Square/Linear Footage of Work: �'7> Type of Work: ❑ Addition ❑ Alteration 3/New I ❑ Repair/Replace ❑ Demolition Description of Work: Specify color of color thru tile: Submittal Fee $200 ` C� Permit Fee $ CCF $ ( T . 4/6 CO/CC $ o C� Scanning Fee $ �' Radon Fee $ 1 ''11 DBPR $ (U • Notary $ V `-f� go Double Fee $ Technology Fee $ �`' ` Training/Education Fee $ Structural Reviews $ G3 C)U , C'C3 Bond $ ��� ` ao . �� • W TOTAL FEE NOW DUE $ , _ (Revised02/24/2014) � 3!s; �. ZC) �:-;2Q - co 20 0 . SG �L:� -�� �j:: �)rZ---�-CJ9 Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must_beposted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature :2_ OWNER or AGENT The foregoing instrument was acknowledged before me this day of 1 1 20 )'i by i�4 who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Ln�� Seal: i---------- - - �- N Notary Public State of Florida Abby Leon < My Commission GG 117123 CONTRACTOR The foregoing instrument w acknowledged before me this 2-1-day of 20 by 10 C� who is personally known to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: ��"n� Aqua ` Seal: --- APPROVED BY r' Iff /I,-", l - Plans Examiner 41 Structural Review (Revised02/24/2014) ; •*^ ° ;; NADINE AGUAS MY COMMISSION # GG090407 as Zoning Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 SWIMMING POOL OWNER'S CERTIFICATION Date 5 Lv4 I G Miami Shores Village Building & Zoning Department Attention: Building Official I certify that I am the legal owner of the property described as located at ICI 21 N-� 104 SYo!)rts �L 33i3 S In accordance with Section 33-12(f), Code of Metropolitan Dade County, I certify that I understand and agree that the swimming pool to be constructed at the above address cannot be used or filled with water until separate permit has been obtained for an approved safety barrier, and such barrier erected, inspected and approved. I further understand that this certification, however, does not eliminate the need for obtaining a permit and erecting and approved barrier prior to final inspection and use of the pool. Legal Owner #11.1 24Yl/ Note: This certification is to be submitted with a swimming pool permit application in duplicate. Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 NOTICE OF REQUIREMENTS RESIDENTIAL SWIMMING POOL, SPA AND HOT TUB SAFETY ACT I (We) acknowledge that a new swimming pool, spa or hot tub will be constructed or installed at � lj z) ut= 104 5,-f- l am, Sh-yrs ILL 3D3 R Miami Shores, FL, and hereby affirm that one of the following methods will be used to meet the requirements of Chapter 515, Florida Statues and the Florida Building Code R4101.17. Please Initial the method(s) to be used: The pool will be equipped with an approved safety pool cover that complies with ASTM F1346-91. (Submit Manufacturer's Specifications). A continuous, one-piece (child) barrier meeting the requirements of Florida Building Code R4101.17.1.15 will protect the pool perimeter. The plans shall show the fence location and method of attachment, including one end that shall not be removable without the aid of tools. (Submit Manufacturer's Specifications). A combination of non -dwelling walls and fences (screen enclosure, child fence, masonry fence walls, chain link or wood fence, etc.) will protect the pool perimeter. The plans must specify the type and location of all non dwelling walls. Florida Building Code, R4101.17.1 Any combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all windows and doors will be equipped with exit alarms complying with Florida Building Code, R4101.17.1.9 (Submit Manufacturer's Specifications). Any combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all doors will be equipped with a self -latching device with positive mechanical latching/locking installed a min. 54" above the threshold. If this option is selected, submit plans showing all types and location of all perimeter protection. The plans must also show the location and type of all openings, and the hardware type for each location. (Submit Manufacturer's Specifications). In accordance with the Code, the pool may not be filled with water without compliance with the Private Swimming Pool Safety Requirements, and upon expiration of the permit, the pool shall be presumed to be unsafe. Iynderstand that not having one of the above Installed will constitute a violation of ChapterhZ, F.S ., an d will be considered as committing a misdemeanor of the second degree, punish�(e as provided in Section 775.082 or Section 775.083 F.S . This form must be signed by the.oymer/aggnt.�nd the prime contractor. 0ONTRACTOR'S SIGN TU E AND DATE 0,0 d ( G \o(� .y\-D CONjkKTOR'S NAME (PLEASE PRINT) NADINE AGUA3 MY COMMISSION # GG090407 EXPIRES April 04.2021 -d ✓/ \ / V OWNER'S SIGNATURE AND DATE Notary Public State of Florida 0 R'§ NAME TLEASE PRI Abby Leon My Commission GG 117123 Expires 10/1612021 NOTARY PUBLIC Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RESTRICTIVE COVENANT PROTECTIVE POOL ENCLOSURE KNOW ALL MEN BY THESE PRESENTS: WHEREAS, the undersignedflwgi LbL✓ is/are the fee simple owner(s) of the following described property situated and being in Miami Shores Village, Florida: Address: l�J 2 I NE )y� ( �S` ► 1 �I ,'are►, Snm5 �_ 3 3 Whereas, the undersigned owner(s) 4C desire to utilize said Lot(s) as a single building si e, and the undersigned owner(s) do(es) hereby declare and agree as follows: I. That the property will not be used in violation of any ordinances of Miami Shores Village or Miami -Dade County now in effect or hereinafter enacted. II. That the purpose of the covenant is to induce Miami Shores Village to issue a permit for a pool where the required enclosure is not on the subject property where the pool is located. Ill. That if any of our adjoining neighbors remove any portion of their fence or wall, or if our/my property shall fail to meet code requirements for pool barriers, we, as owners will immediately installs a protective enclosure to meet code requirements and will obtain a permit for such fence. IV. That, I/we, as owner(s) hold Miami Shores Village harmless for any negligence or injury that results from not having the enclosure. V. If enclosure belongs to said property, I agree to maintain & or replace said enclosure in the event that is damaged or removed by any case. NOW, THEREOF, for good and valuable consideration, the undersigned do(es) hereby declare that he/she will not convey or cause to be conveyed the title to the above property without requiring the successor in title to abide by all terms and conditions set forth herein. FURTHER, the undersigned declare(s) that this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to the above property and shall constitute a covenant running with the land and shall be binding upon the undersigned, his/her successors and assigns and may only be rele6sed by Miami Shores Village, or its successors, in accordance of said Village then in effect. OWNER SIGN & PRINT OWNER SIGN & PRINT I Hereby Certify that on this day personally appeared before me j,„n i J1 ) w and has produced ID # 1� 000 3 90 7 io .3320 as identification and he/she acknowledge that he/she executed the foregoing, freely and voluntarily, for purposes there in expressed. 1 ;_ SWORN TO AND SUBSCRIBED before me on this 2 day of U , 20(13 "F'0 � NOTARY PUBLIC STATE OF FLORIDA (Revised 05/2209 �4►o.N Notary� ry eon��� state of Florida y Commission GG 117123 yp 1o11812021 PROPERTY ADDRESS: 1421 NE 104th STREET MIAMI SHORES, FL. 33138 FLOOD ZONE INFORMATION: COMMUNITY NO. 120652 PANEL NO. 0306 SUFFIX L FIRM DATE: 09-11-2009 FLOOD ZONE: AE +9.0' LEGAL DESCRIPTION: LOT 6, BLOCK 3, OF "RIVER BAY PARK ADDITION ", ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 40, AT PAGE 72, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA. SURVEYOR'S NOTES: LEGAL DESCRIPTION WAS FURNISHED BY THE CLIENT. THIS SURVEY WAS CONDUCTED FOR THE PURPOSE OF A BOUNDARY SURVEY LEGAL DESCRIPTION SUBJECT TO ANY DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR RECORDED EASEMENTS. THERE MAY BE LEGAL RESTRICTIONS ON THE SUBJECT PROPERTY THAT ARE NOT SHOWN ON THE MAP OF SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF MIAMbDADE COUNTY, OR THE RECORDS OF ANY OTHER PUBLIC AND PRIVATE ENTITIES AS THEIR JURISDICTIONS MAY APPEAR. THIS SURVEY DOES NOT DELINEATES THE REGULATORY JURISDICTION OF ANY FEDERAL, STATE, REGIONAL OR LOCAL AGENCY BOARD, COMMISSION OR OTHER ENTITY. THE ELEVATIONS OF WELL -IDENTIFIED FEATURES AS DEPICTED ON THIS SURVEY AND MAP WERE MEASURED TO AN ESTIMATED VERTICAL POSITIONAL ACCURACY OF 1/10 FOOT FOR NATURAL GROUND SURFACES AND 51100 FOOT FOR HARDSCAPE SURFACES, INCLUDING PAVEMENTS, CURBS AND OTHER MAN-MADE FEATURES AS MAY EXIST. WELL -IDENTIFIED FEATURES AS DEPICTED ON THIS SURVEY AND MAP WERE MEASURED TO AN ESTIMATED HORIZONTAL POSITIONAL ACCURACY OF 1/10 FOOT UNLESS OTHERWISE SHOWN. THE MAP OF SURVEY IS INTENDED TO BE DISPLAYED AT THE STATED GRAPHIC SCALE IN ENGLISH UNITS OF MEASUREMENT. ATTENTION IS BROUGHT TO THE FACT THAT SAID DRAWING MAY BE ALTERED IN SCALE BY THE REPRODUCTION PROCESS ALL MEASUREMENTS SHOWN ARE IN THE UNITED STATES STANDARD FEET REFERENCE BENCH MARK: GNSS Statistics StdDevH=0.07,StdDevV=0.03',RefID=606, RefLat=N25°57'56.76786",RefLon=W80° 10'02.22280",RefHgt=-56.98', SHOWN ELEVATIONS ARE REFERRED TO N.G.V.D. OF 1929. THE SURVEYOR MAKES NO REPRESENTATION AS TO OWNERSHIP, POSSESSION OR OCCUPATION OF THE SUBJECT PROPERTY BY ANY ENTITY OR INDIVIDUAL. SUBSURFACE IMPROVEMENTS AND/OR ENCROACHMENTS WITHIN, UPON, ACROSS, ABUTTING OR ADJACENT TO THE SUBJECT PROPERTY WERE NOT LOCATED AND ARE NOT SHOWN. NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ADDITIONS AND DELETIONS TO THIS MAP OF SURVEY BY OTHER THAN THE SIGNING PARTY ARE PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY. THIS MAP OF SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED HEREIN AND THE CERTIFICATION DOES NOT EXTEND TO ANY UNNAMED PARTY. IN MY PROFESSIONAL OPINION, THIS " BOUNDARY SURVEY', MEETS THE STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 5J-17.05 FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES. AND, IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. 360° SURVEYING AND MAPPING, LLC FLORIDA CERTIFI TE OF AUTHORIZATION NO. LB 6356 OSCA . BAEZ-CUSIDO, P.L.S. R TERED SURVEYOR AND MAPPER NO.5034 ATE OF FLORIDA. FOUND DRILL — _ HOLE @ 0.3' O/S S. BISCAYNE CANAL POOL i ag POOL EQUIPMENT POOL DECK ' t 0 cl O N a a g ai ce F- Q m r oma � 0.6 R I I I I I I I I SE CORNER LOT 1 BLOCK 3 �- - 375.0' F.I.P.1 0 F.I.P.j 0 (NO ID.) (NO ID.) `/ C /RE$ AERBA �pl f ✓ f ` / / ///F.F.EI 0 N GATE i X&RPORCH UTILITY O.T / ' 23.4% 2.�/ VE STOGY/ )�NCE�#,121� / 6,,BLOCK,3 PAk- DDIT.IOl , /cl i21.T ASPHALT DRIVEWAY 4' CONC. SIDEWALK, L 75.001 �.. 12'PARKWAY r GATE ASPHALT APPROACH NE 104th STREET _50' PUBLIC RIGHT-OF-WAY_ _ 19 -/- ASPHALT PAVEMENT 7b N FOUND DRILL HOLE @ 0.3' OIS S. 0 I - — ...--- — • . • .1ST7, :; .... .... . I 2 '.7 4 b �� 7 •A• 9 10 II 3. I! • • •••• •• • • 2 .3 4 5 IS T7O 9•• •�i• I I Ali 14 • • • • • 0000 i LOCATION MAP A (NOT TO SCALE) N N c SCALE:1" = 20' W J U- J W Q Q LEGEND t C/o°'� A/C UNIT ELEVATION J V 2 FIRE HYDRANT ZMETER (WATER) O ROPERTY LINE a.. `CG) TILITY POLE Q U G m ABBREVIATIONS A/C = AIR CONDITIONER UNIT C.L.F. = CHAIN LINK FENCE C.B.S. = CONCRETE BLOCK B STUCCO CONC. = CONCRETE 0 = DIAMETER F.F.EL. = FINISHED FLOOR ELEVATION F.I.P. = FOUND IRON PIPE H = HEIGHT ID. = IDENTIFICATION OIS = OFF SET PG. = PAGE P.B. = PLAT BOOK GEOTECHNICA1 1 ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES Ecoc DYNATECH ENGINEERING CORP, Miami, November 27, 2019 Mr. Chris Lopez J.L.0 ENTERPRISES, INC. 2800 NW 32"d Avenue Miami, FL 33142 Re: Proposed Pool Deck @ 1421 Northeast 104" Street Miami Shores, FL 33138 Dear Mr. Lopez: V V W.DYNATECHENGINEERING.COM 6pp- os-o-Aud Pursuant to your request, DYNATECH ENGINEERING CORP. (DEC) performed a site inspection on November 27, 2019 at the above referenced project. The purpose of our inspection was to document the pile logging operations. All piles consisted of 3 %2" diameter helical piles with 12"/14" helices, placed at the locations marked by the client to the depths indicated on the attached field logs to achieve a bearing capacity of 6 tons in compression. Enclosed find copies of our field log inspection. It has been a pleasure working with you and look forward to do so in the near future. Sincerely yours, M /o �O -- F No Wissam Naamani, P.E. 3 85 ; DYNATECH ENGINEERING CORK. * " Florida Reg. No. 39584 iQ : ,ASrATEOF : I Special Inspector No. 757 1scs'ZoR�DA- Certificate of Authorization No.: CA 544, PAV" � 2\x� '�/11111 %a,0 REPORT OF PILE DRIVING INSPECTION DYNATECH REPORT OF PILE DRIVING INSPECTION CLIENT : J.L.0 ENTERPRISES, INC. PROJECT : Proposed Pool Deck @ ADDRESS : 1421 Northeast 104" Street, Miami Shores, FL ENGINEERING CORP. 750 WEST 84TH STREET HIALEAH, FLORIDA 33014 (305)828-7499 DATE: 11-27-2019 HAMMER USED: Eskridge 2 speed PAGE NO.: 1 of 1 PILE TYPE PILE NO. 1 2 3 4 5 6 7 8 9 10 REMARKS 1 500 500 500 500 700 500 600 700 700 600 1 2 700 700 600 700 900 700 800 800 800 800 2 3 900 800 800 900 1000 900 1000 900 1000 900 3 4 1100 1100 1000 1100 1000 1100 1200 1100 1200 1100 4 5 1200 1100 1200 1200 1100 1250 1200 1200 1500 1400 5 6 1200 1200 1200 1200 1100 1400 1400 1300 1600 1500 6 7 1400 1300 1500 1300 1200 1600 1700 1500 1700 1800 7 8 1400 1500 1700 1300 1500 1900 1800 1900 1900 1900 8 9 1700 1800 1700 1400 800 900 800 800 800 800 9 10 900 700 800 1700 900 900 800 800 800 800 10 11 900 800 900 700 950 950 850 900 900 900 11 12 13 1000 800 900 700 950 900 900 900 900 900 12 1000 900 950 800 900 900 900 950 900 1000 13 14 15 1000 1000 1000 900 1000 1000 900 1000 1000 1000 14 1000 1000 1000 900 1000 1000 1000 1000 1000 1100 15 16 1100 1100 1100 1000 1100 1100 1000 1100 1100 1100 16 17 1150 1100 1150 1000 1150 1150 1100 1150 1100 1150 17 18 1150 1100 1 1200 1100 1200 1200 1200 1200 1200 1150 18 19 1200 1150 1350 1250 refusal 1250 1300 1 1250 1200 1200 19 20 1250 1150 refusal refusal refusal refusal refusal 1200 1300 20 21 refusal 1200 1300 refusal 21 22 1300 refusal 22 23 refusal 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 31 32 32 33 33 34 34 35 35 Pile Size (Inches) 3'/:' 3%:" 3%:" 3%:" 3%z" 3%:" 3%:" 3'/2" 3'/z" 3%z" Length (Feet) 7' 7' 7' 7' 7' 7' 7' 7' 7' 7' Bearing Required (Tons) 6T 6T 6T 6T 6T 6T 6T 6T 6T 6T Penetration Lasts Blows N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Form ula Tons (Tons) 6+ 6+ 6+ 1 6+ 6+ 1 6+ 6+ 1 6+ 6+ 6+ Depth Driven Feet 21' 23' 20' 1 20' 19' 1 20' 20' 1 20' 22' 21' NOTE: Depth Driven Refers to Existing Ground Elevation. Field Tech: D.B. SITE PLAN j-v us:Nq 11 OO 1+'e . C-p1_- 3.s -1r rX4AA--"F Re-fo-- 2A Fr r — 'ILES & GRADE BEAMS PLAN 0 N Revisions Q7 11/06/19 0 a „ s e Y S W C J bo 'E. % J O rn ` N M h OW J Js O t LL d x a n W a uz O CL O W a a „ Y yB 4 sg g 2 V J 0 R Z a B 0 a s W W 0 U uW E D, W�00 `�B �� IaW0 Uoo�c�F� 0 Q� e ° U W J 02 7 `" .Y� a Job No 19-013 Date: 10-09-19 Sde' S As Shown y AR-00015344 e 13 s sm � AA-26001560 � Sheei No. p S-1 8R CONTRACTOR AND BUILDER SHALL %ERIEY ALL DIMENSIONS ON DRAWWNOS AND CONDITIONS AT JOB SITE PRIOR TO THE START OF ANY WORN AND REPORT ALL DISMPANCWS 70 THE ARCHITECT/ENCMEER M WRITMG ONLY. DO NOT SCALE THE DA-GS TO TARE DIMENSIONS, DAEXISTING & PROPOSED FOUNDATIO SCALE: k•.r-O- GEOTECHNICAL I ENVIRONMENTAL FMATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES , . EC DYNATECH ENGINEERING CORP. Miami, August 8, 2019 Mr. Chris Lopez J.L.U. ENTERPRISES, INC. 2800 NW 32"d Avenue Miami, FL 33142 Re: Proposed Pool @ 1421 NE 104 Street Miami Shores, FL 33138 Dear Mr. Lopez: W N W.DYNATECHENGINEERING.COM oe-9111* 2 2,0 Cl i Pursuant to your request, DYNATECH ENGINEERING CORP. (DEC) conducted a site inspection on August 8, 2019 at the above referenced project. The purpose of our inspection was to document pile driving operations only. All piles consisted of 14 inches diameter auger cast piles placed at the locations marked by the client to the depths indicated on the attached field logs to achieve a bearing capacity of 40 tons in compression. Enclosed please find copies of our field inspection logs. It has been a pleasure working with you and look forward to do so in the near future. Sincerely yours,SAAD Ilk i 10 Wissam Naamani, P. E. DYNATECH ENGINEERING CORP.,- NO.39584 Florida Reg. No. 39584 = * ' ' �. Special Inspector No. 757 p �, STATE OF ' Ir Certificate of Authorization No.: i� F (pR10P''���'�N sI�ONAL �liillll 750 WEST 84TH STREET, HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM j4tEC DYNATECHENGINEERING CORP. REPORT OF AUGERED CAST PILES DATE : 08-08-19 PAGE No.: 1 of 2 CLIENT : J.L.U. ENTERPRISES, INC. ADDRESS : 2800 NW 32"d Avenue, Miami, FL 33142 PROJECT : Proposed Pool @ ADDRESS : 1421 NE 104 Street, Miami Shores, FL 33138 Pile Number 1 2 3 4 5 6 7 Auger Diameter (Inch) 14 14 14 14 14 14 14 Pile Length (Ft) 20 20 20 20 20 20 20 Theoretical Pile Volume Ft3 21.4 21.4 21.4 21.4 21.4 21.4 21.4 # Of Pump Strokes 40 31 32 30 29 30 31 Volume Per Pump Stroke(Fe) 1.05 1.05 1.05 1.05 1.05 1.05 1.05 Actual Pile Grout Volume Ft3 42 32.55 33.6 31.5 30.45 31.5 32.55 Actual / Theoretical Volume 1.96 1.52 1.57 1.47 1.42 1.47 1.52 Reinforcing Size 5 # 5's wi #3 ties @ 6" ox. 20' 5 # 5's w/ #3 ties @ 6" ox. 20' 5 # 5's w/ #3 ties @ 6" ox-20' 5 # 5's w/ #3 ties @ 6" ox. 20' 5 # 5's w/ #3 ties @ 6" ox. 20' 5 # 5's w/ #3 ties @ 6" ox. 20' 5 # 5's w/ #3 ties @ 6" ox. 20' Grout Truck # 932 932 932 932 932 932 932 REMARKS: Field Tech: wo 2 750 WEST 84TH STREET, HIALEAH, FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM t-EC DYNATECHENGINEERING CORP. REPORT OF AUGERED CAST PILES DATE : 08-08-19 PAGE No.: 2 of 2 CLIENT : J.L.U. ENTERPRISES, INC. ADDRESS : 2800 NW 32" Avenue, Miami, FL 33142 PROJECT : Proposed Pool @ ADDRESS : 1421 NE 104 Street, Miami Shores, FL 33138 Pile Number 8 9 10 Auger Diameter (Inch) 14 14 14 Pile Length Ft 20 20 20 Theoretical Pile Volume(Ft)3 21.4 21.4 21.4 # Of Pump Strokes 33 40 39 Volume Per Pump Stroke Ft3 1.05 1.05 1.05 Actual Pile Grout Volume Ft3 34.65 42 40.95 Actual / Theoretical Volume 1.61 1.96 1.91 Reinforcing Size 5 # 5's Wi #3 ties @ 6" ox.20' 5 # 5's w/ 43 ties @ 6" ox.20' 5 # 5's Wi 43 ties @ 6" ox.20' Grout Truck # 932 912 912 KLMAKKJ: Field Tech: wo 3 750 WEST 84TH STREET, HIALEAH, FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM C4tE AND 10' EACH PROMGE 12' X 36' SLAG BAND WITH 5 1 H TOP AND BOTTOM, OVER PILING ' (SEC DETAIL IN THIS PAGC) ++ 3 T.-3' ��lli�//1� M►\ I� POOL PILING LAYOUT scALE a/4•-1'-0' OPTIONAL: PROVIDE CONTRASTING TILE OR 80- NOSE 12' CONCRETE SLAB PflONOE d3 O 6- TILE ON STEPS k BENCH EDGE 4 O 10' EACH WAY NOR. k VERT W/ 16 MIN. SPLICE TOP AND BOTTOM (ONLY FOR 9' SPA WALL) B• . IN •� _ ___ __ $PAA�TER LINE—�_—' ___ 510 14' l sTo � M0011 IHOOK t i33'I:�i-i9f _ lei. t �' I It](3NY 11333 '.ice. �ii tP _ _ Y AUGER PILE S H 2' CONCRETE SLAB 24. M I / 4 0 TO- EACH WAY - .si. AND BOTTOM. MAIN DRAIN (SEE DETAIL IN PACE 3-4) Icy`` 1fi I_ LPRONDE 36• % 38• % S• DROP AROUND EAON PILE 14' AUGER PILE SECTION B ,4- A PILE SCALE :1/2'-1'-0• NOTE: Au 3P1Kz wsr eE 4e aAR aA PRONOE ]• MIN. CLEAR caNa1E1E COVER POOL N POOL COPING COPING N VV �P POOL DEC( POOL DECK B. (BY OTHERS) BY OTHERS) -- - - —.---- ----- -- ---- A u ��.» 6' CERAMIC TILE FINISH CLEAR INTERIOR POOL PLASTER PROL4DE // 4 OVERT 1O' NOR O ROVIDE / 4 C 10- OR Q VERT 3'_O. 12' CONCRETE SLAB SE W/ 1 4 0 TO- EACH WAY TOP AND BOTTOMq S?LICE 4+6. . 9 STD No. H ` O t 2a•MN ; I sm Hoac POOL COPING .—POOL DECK 4 0 �12- CONCRETE SLAB EACH WAY f K_SPLICE •, PROVIDE W/ / 4 O 10• TOP AND BOTTOM �. 36' X 36' X 51 DROP ... ^ V . �• ..,,/ iir.n.,. %�� . ^, PRONOE AROUNO EACH PILE 14' AUG PILE PROVIDE 12' X 36' -SLAB BAND VATH 5 4 TOP MAIN GRAIN (SEE. 36' x 36' X 5' DROP AND BOTTOM. OVER PILING (SEE DETAIL ON THIS PACE) DETAIL IN PAGE 3-4) AROUND EACH PILE 14' AUGER PILE ALL 6PlKS MUST BE M BM aA PX0N0E3 �" °E"� G�G�� � SECTION C HO [: ILL SPUCE MUST BE b 6M aA SCALE:1/2'�1'-0' 3• MW. CENT CONCRETE COL£R O z Fm W z ra: o`Oo A SHEET NO: 3 OF: 4 ,A T Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 7561 9" •••• MIAMI SHORES VILLAGE . . NOTICE TO BUILDING DEPARTMENT •••�•• ••• OF EMPLOYMENT AS SPECIAL INSPECTOR UNDER;;• THE FLORIDA BUILDING CODE000000 ••••: .••••Y I (We) have been retained by?m& Pafi�) to perform special :isp2ctc: services under the FI rida Building Code at the project on the below I sted ,structure; •IS •df (date). I am a re is red arc i c r pro essiona engineer licensed in the State of PlgrWg.: • go .. RO ESS NUMBERS: • • • • SPECIAL INSPECTOR FOR PILING, FBC 1822.1.20 (R4404.6.1.20) ❑ SPECIAL INSPECTOR FOR TRUSSES >35LONG OR 6' HIGH 2319.17.2.4.2 (R4409.6.17.2.4.2) ❑ SPECIAL INSPECTOR FOR REINFORCED MASONRY, FBC 2122.4 (R4407.5.4) ❑ SPECIAL INSPECTOR FOR STEEL CONNECTIONS, FBC 2218.2 (R4408.5.2) ❑ SPECIAL INSPECTOR FOR SOIL COMPACTION, FBC 1820.3.1 (R4404.4.3.1) ❑ SPECIAL INSPECTOR FOR PRECAST UNITS & ATTACHMENTS, FBC 1927.12 (R4405.9.12) ❑ SPECIAL INSPECTOR FOR Note: Only the marked boxes apply. The Ilowin in ' id I(s) emplo led b this firm or me re authorized r pr e tativ to perform inspection 1. 2. / 3. 4. �a *Special Inspectors utilizing authorized representatives shall insure the authorized representative is qualified by education or licensure to perform the duties assigned by the Special Inspector. The qualifications shall include licensure as a professional engineer or architect; graduation from an engineering education program in civil or structural engineering; graduation from an architectural education program; successful completion of the NCEES Fundamental Examination; or registration as building inspector or general contractor. I, (we) will notify Miami Shores Village Building Department of any changes regarding authorized personnel performing inspection services. I, (we) understand that a Special Inspector inspection log for each building must be displayed in a convenient location on the site for reference by the Miami Shores Village Building Department Inspector. All mandatory inspections, as required by the Florida Building Code, must be performed by the County. The Village building inspections must be called for on all mandatory inspections. Inspections performed by the Special Inspector hired by the Owner are in addition to the mandatory inspections performed by the Department. Further, upon completion of the work under each Building Permit I will submit to the Building Inspector at the time of final inspection the completed inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and professional judgment those portions of the project outlined above meet the intent of the Florida Building Code and are in substantial accordance with the approved plans. Sign and Sealed Engineer/ArcWte t kaaa Name D171,t � (PRINK Address .DATE- ` Phone No. (�i 33i! / Created on 6/10/2009 .M • . ...• •..••. .� STRUCTURAL CALCULATION,.• •�•«< ��.,• • �r.c,.•. ; ; ;;,,;,f�ti •.. • •••'�.•� �. stir•#c PROPOSED SWIMMING POOL }':''`:} �'•;•;• • f...% %. • • • w 1421 NE 104 STREET MIAMI SHOER , FL 33138. �%,.���r1TE F,IpQ���,��ii � O�, O 26 p 3 OF ; 11il ONAI Vicente Franco P.E. LIC. No. 62561 8690 NW 109 CT MIAMI , FL 33178 STRUM 'pp 'oo ` , . . .... ...... ...... .. ...... TABLE OF CONTENT • • • • • "Sege** e .. . e e e.e. , • • ..e:, .e..r• .. e,. :: . • 00b00% . d► ..ti • ♦ • ..... .. . e .. • • • �••I�. e... CHECK PILE CAPACITY • ..r .r : .. 1 •.�.., ................................................... • . ♦ .- a ... ti�►M�A .• CHECK PUNCHING SHEAR '::;.... 2.::.' ................................................... e..ee. CONCRETE WALL �..:.... 3 .. .................................................................�: .... BOTTOMSLAB.............................................................................. 5 SLAB BAND DESIGN...................................................................... 7 1 Vicente Franco P.E. CHECK PILE CAPACITY POOL POOL HEIGHT: h = 5 FT BOTTOM SLAB THICKNESS = 12 IN WALL THICKNESS = 8 IN fc = 5000 PSI fy = 60000 PSI 0119 TENSION CAPACITY = 17 T COMPRESSION CAPACITY = 40 T LATERAL CAPACITY = 2 T PILE DIAMETER = 14 IN PILE SPACING LEFT b1 = 7.25 FT PILE SPACING RIGHT b2 = 7.25 FT TRIBUTARY WIDTH T1 = 3.67 FT TRIBUTARY WIDTH T2 = 9 FT CHECK TENSION CAPACITY: TRIBUTARY AREA = 59.23 SF HYDROSTATIC PRESSURE = 11.373 T DEAD LOAD: SLAB WEGHT = 150 ` 12/12 "AREA / 2000 = WALL WEIGHT = 150 * 8/12 * h ` (b1+b2)/2 / 2000 = DEAD LOAD = 6.25 T . . . . ...... s:s{ss s:•:s� fssssf s•••t• os.s•� 4.44 T 1.81 T UPLIFT (HP-DL*0.6) = 7.62 T OK < TENSION CAPACITY CHECK COMPRESSION CAPACITY: LIVE LOAD = 9.48 T DEAD LOAD = 6.25 T TOTAL = 15.73 T .... ... ..... . .. ...... +•t• •0000• }111:} ;S•%%% ...It ss .• ss}sso • o • . .• . f of • ss;lfs ..ss. .••ss fossil . . . .. t. . • . OK < COMPRESSION CAPACITY 2 Vicente Franco P.E. CHECK PUNCHING SHEAR AT BOTTOM SLAB POOL POOL HEIGHT = 5 FT BOTTOM SLAB THICKNESS = 12 IN WALL THICKNESS = 8 IN fc = 5000 PSI EFFECTIVE WIDTH = 8 IN d = 9 IN ho = 21 IN bo = 84 IN REACTION OVER PILE: LIVE LOAD = 9.48 T DEAD LOAD = 6.25 T Vu = 49.7 K CONCRETE SHEAR CAPACITY: �Vc = 181.8 K OK PILE . . .... ...... ...... .. ...... ttt tt tt .• •t=tt; tttit! '••t•' CRITICALAREA PERIMF-TER "t• •� OK > PUNCHING SHEAR Cantilevered Retaining Wall Lic. # : KW-06010683 Licensee : Vicente Franco Description : Cantilevered Wall Criteria Retained Height = 5.00 ft Wall height above soil = 0.00 ft Slope Behind Wall = 0.00 : 1 Height of Soil over Toe = 0.00 in Water height over heel = 0.0 ft Vertical component of active Lateral soil pressure options: NOT USED for Soil Pressure. NOT USED for Sliding Resistance. NOT USED for Overturning Resistance. Design Summary Wall Stability Ratios Overturning = 4.01 OK Sliding = 0.98 OK Slab Resists All Sliding ! Total Bearing Load = 1,500 Ibs ...resultant ecc. = 0.96 in Soil Pressure @ Toe = 241 psf OK Soil Pressure @ Heel = 209 psf OK Allowable = 2,000 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 289 psf ACI Factored @ Heel = 251 psf Footing Shear @ Toe = 4.9 psi OK Footing Shear @ Heel = 0.0 psi OK Allowable = 106.1 psi Sliding Calcs Slab Resists All Sliding ! Lateral Sliding Force 810.0 Ibs less 100% Passive Force = - 194.5 Ibs less 100% Friction Force = 600.0 Ibs Added Force Req'd = 15.5 Ibs NG ....for 1.5 : 1 Stability = 420.5 Ibs NG Load Factors Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.600 Seismic, E 1.000 Soil Data Allow Soil Bearing = 2,000.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 45.0 psf/ft Toe Active Pressure = 30.0 psf/ft Passive Pressure = 389.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf Friction Coeff btwn Ftg & Soil = 0.400 Soil height to ignore for passive pressure = 0.00 in Calculations per ACI 318.11, ACI 530-11, IBC 2012, CBC 2013, ASCE 7.10 • • •••. •••••• ...... 0• •.. ...... 000*00 •••+• ••••• iiiiii •••••• •••••• •• •••• •••••• Stem Construction Top Stem • •.,. • • • • • • •.. Design Height Above Ftq Wall Material Above "Ht" Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Moment.... Actual Moment ..... Allowable Shear..... Actual Shear..... Allowable Wall Weight Rebar Depth 'd' Lap splice if above Lap splice if below Hook embed into footing Concrete Data fc Fy Stem OK ft= 0.00 •••••� • • ��+��� •...•. ...... • = Concrete + •+ • .". •••••• in = 8.00 in= 12.00 ' • • • ••••.• = Center • o • • Ibs = ft-I = ft-I = psi = psi = psf = in = in = in = in = psi = psi = 0.429 900.0 1,500.0 3,493.8 18.8 106.1 100.0 4.00 13.24 6.00 6.00 5,000.0 4 Cantilevered Retaining Wall LLic. #: KW-06010683 Licensee : Vicente Franco Description : cantiieverea waii Footing Dimensions & Strengths Toe Width = 6.00 ft Heel Width = 0.67 Total Footing Width = 6.67 Footing Thickness = 12.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft fc = 5,000 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm.= 3.00 in of Item Heel Active Pressure Surcharge over Heel Toe Active Pressure Surcharge Over Toe Adjacent Footing Load Added Lateral Load Load @ Stem Above Soil Footing Design Results Toe Heel Factored Pressure = 289 251 psf Mu' : Upward = 0 0 ft-lb Mu': Downward = 0 0 ft-lb Mu: Design = 1,500 0 ft-lb Actual 1-Way Shear = 4.88 0.00 psi Allow 1-Way Shear = 106.07 106.07 psi Toe Reinforcing = # 4 @ 18.00 in Heel Reinforcing = # 4 @ 18.00 in Key Reinforcing = None Spec'd Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S * Fr Heel: Not req'd, Mu < S * Fr Key: No key defined & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Ibs ft ft-lb 810.0 Total = 810.0 Resisting/Overturning Ratio Vertical Loads used for Soil Pressure = 2.00 1,620.0 Soil Over Heel = Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = * Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth @ Stem Transitions = O.T.M. = 1,620.0 Footing Weight = = 4.01 Key Weight = 1,500.0 Ibs Vert. Component ••Y• •• ...... ...... ...000* •.. • Y•Y••• •.. .Y•• • • • ...0• ...... . .+ . • .....RAISTINO..... • Y++Y:+ Force Dista*60 • • Moment Ibs• • ft ft-lb :....: 0.0 0.0 • 500.0 6.33 3,166.7 1,000.0 3.33 3,333.3 Total = 1,500.0 Ibs R.M. = 6,500.0 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. 5 ONE WAY CONCRETE SLAB DESIGN - ACI COEFFICIENTS Design is for largest span and worst coefficient condition Pool height hp := 5 • ft Maximum span Is := 9 • ft + 0 • in • • • • Width bs:= 12 in •��. • •�•��• Slab deep hs:= 12• in ;..•;� ,•••; $$less •.• • ••Goes •• 4 4 :::�:: S: .• ..s..e i—•in-0.5•—•in d h—3.0•n— ds =in 8.25- ;;•��• o ..... • s•=s 8 8 .... •• ••$oe• ' • � •� iijiie Water unitweight �yw:= 62.4 • pcf :':'t; :';see ;•••.• Concrete unitweight 7c:= 150•pcf �G�G�• ,,,,;, Ultimate bad • • 0000 qu := 1.2•hs•bs•-yc+ 1.6•bs•hp••yw qu = 679.2 • plf Maximum moment 12 Mu •_ qu s Mu = 73354 • in • lbf 9 fy := 60000 • psi fc := 5000 • psi 0.5015 f 2 • bs • ds2 2 A:= Y B--0.85•fy•bs•ds fc —B— B2-4•A•Mu p := max 0.0018, 2•A N. p = 0.0018 As := p - bs • hs As = 0.259 • in Use #4 @ 12" top and bottom each way Maximum shear I _ Vu := qu • s 2 - ds Vu = 2589 • Ibf Concrete shear capacity ,�Vc := 0.75. 1.0. 2 fc • psi • bs • ds (�Vc = 10501 • Ibf (� Vc = 525071bf 2 Vu islessthan haft concrete cap adty. No shear rebar is required woes •.eeee Y. • eew . • �s..je ?•t•t} �•etj ' floe .• Ij}tl• 'j.••s .••jj }tttt} ...... .. . . . 00 ...... 7 EXTERIOR CONCRETE SLAB BAND DESIGNED AS BEAM -ACI COEFFICIENTS Design is for largest span and worst coefficient condition Pool height hp := 5 • ft Wal thickness tN,:= 8 • in •r,• Maximum clear span In := 4 • ft + 3 • in Pile cap width (assumed beam width) bb:= 36- in i..�i ,•+•i` }tiflj ti.•i i�•tts Slab deep hs:= 12 in iit;ii ii •• ...�t aijit= db := hs — 3.0 • in — in — 0.5 • in db = 8.25 • in }••881 `•i. 8 8 •+ �j' Water unitweight lw:= 62.4 • pcf Concrete unit weight 7c := 150 • pcf • • •:. ""' • Trbutary wdth by := 9 + 3.67 • ft . . 2 Ultimate bad qu := 1.2•(tw*hp+hs•bP),'Yc+ 1.6•bp•hp•-Nw qu = 6149.1 • plf Maximum moment 2 qu - In Mu :_ 9 fy := 60000 • psi 0.5015 fy2 bb db2 A :_ fc Mu = 148090 • in • lbf fc := 5000 • psi B:=-0.85•fy•bb.db2 3 fc psi 200 • psi —B — B2 — 4 • A • Mu p := max ,min fy fy 2 • A 8 p = 0.0035 As := p • bb • db As = 1.05 • in Use 5 #4 top and bottom over piles Maximum shear 1 Vu := % • n - db Vu = 8839 • lbf 2 (�Vc := 0.75 • 1.0. 2 f� psi • bb • db (�Vc = 31502 • lbf (�Vc 15751 • lbf 2 Vu is less than half concrete cap adty. No shear rebar is required Otto . . • .... ...... ...... • . .. , ...... Gott •�•+++ !!.. ` !!lift ll .• jt}!f+ Wll+ �ii..+.t •! ♦t;d)+ t....t . t . . .Olt • .. . . .t •....t • . . .... PROPERTY ADDRESS: 1421 NE 104th STREET MIAMI SHORES, FL. 33138 FLOOD ZONE INFORMATION: COMMUNITY NO. 120652 PANEL NO. 0306 SUFFIX: L FIRM Dr',iE:09-11.2009 FLOOD ZONE: AE+9.0' LEGAL DESCRIPTION: LOT 6, BLOCK 3, OF "RIVER BAY PARK ADDITION ", ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 40, AT PAGE 72, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA. SURVEYOR'S NOTES: LEGAL DESCRIPTION WAS FURNISHED BY THE CLIENT. THIS SURVEY WAS CONDUCTED FOR THE PURPOSE OF A BOUNDARY SURVEY LEGAL DESCRIPTION SUBJECT TO ANY DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR RECORDED EASEMENTS. THERE MAY BE LEGAL RESTRICTIONS ON THE SUBJECT PROPERTY THAT ARE NOT SHOWN ON THE MAP OF SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, OR THE RECORDS OF ANY OTHER PUBLIC AND PRIVATE ENTITIES AS THEIR JURISDICTIONS MAY APPEAR. THIS SURVEY DOES NOT DELINEATES THE REGULATORY JURISDICTION OF ANY FEDERAL, STATE, REGIONAL OR LOCAL AGENCY BOARD, COMMISSION OR OTHER ENTITY. THE ELEVATIONS OF WELL -IDENTIFIED FEATURES AS DEPICTED ON THIS SURVEY AND MAP WERE MEASURED TO AN ESTIMATED VERTICAL POSITIONAL ACCURACY OF 1/10 FOOT FOR NATURAL GROUND SURFACES AND 51100 FOOT FOR HARDSCAPE SURFACES, INCLUDING PAVEMENTS, CURBS AND OTHER MAN-MADE FEATURES AS MAY EXIST. WELL -IDENTIFIED FEATURES AS DEPICTED ON THIS SURVEY AND MAP WERE MEASURED TO AN ESTIMATED HORIZONTAL POSITIONAL ACCURACY OF 1/10 FOOT UNLESS OTHERWISE SHOWN. THE MAP OF SURVEY IS INTENDED TO BE DISPLAYED AT THE STATED GRAPHIC SCALE IN ENGLISH UNITS OF MEASUREMENT. ATTENTION IS BROUGHT TO THE FACT THAT SAID DRAWING MAY BE ALTERED IN SCALE BY THE REPRODUCTION PROCESS ALL MEASUREMENTS SHOWN ARE IN THE UNITED STATES STANDARD FEET REFERENCE BENCH MARK: GNSS Statistics StdDevH=0.02',StdDevV=0.03',RefID=606, RefLat=N25' 57'56.76786",RefLon=W80"10'02.22280",RefHgt=-56.98', SHOWN ELEVATIONS ARE REFERRED TO N.G.V.D. OF 1929. THE SURVEYOR MAKES NO REPRESENTATION AS TO OWNERSHIP, POSSESSION OR OCCUPATION OF THE SUBJECT PROPERTY BY ANY ENTITY OR INDIVIDUAL. SUBSURFACE IMPROVEMENTS AND/OR ENCROACHMENTS WITHIN, UPON, ACROSS, ABUTTING OR ADJACENT TO THE SUBJECT PROPERTY WERE NOT LOCATED AND ARE NOT SHOWN. NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ADDITIONS AND DELETIONS TO THIS MAP OF SURVEY BY OTHER THAN THE SIGNING PARTY ARE PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY. THIS MAP OF SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE;USE OF THE ENTITIES NAMED HEREIN AND THE CERTIFICATION DOES NOT EXTEND TO ANY UNNAMED PARTY. CERTIFY TO: SURVEYOR'S CERTIFICATION: IN MY PROFESSIONAL OPINION, THIS " BOUNDARY SURVEY', MEETS THE STANDARDS OF PRACTICE AS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER 5J-17.05 FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES. AND, IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. 360' SURVEYING AND MAPPING, LLC FLORIDA CERTIFI TE OF AUTHORIZATION NO. LB 6356 OSCAR E. B)tfCTJSID0, P.L.S REGISTER SURVEYOR PAD MAPPER NO.5034 STATE OFf LORIDA. r� P �F� S�R�u E�Y BISCAYNE CANAL FOUND DRILL FOUND DRILL — _ HOLE @ 0.3' O/S S. �� �� ✓ % ''' ^6 HOLE @ 0.3' OIS S. "oo F� — 2' CONC. SEAWALL N c6 /j LL LL: b � / yam;! j' � .5 � 10.2' .9' 0 15.8' AC < . t x—x 39.1' <.i yoh ONE STORY RESIDENCE # 1421 LOT 6, BLOCK 3 z o RIVER BAY PARK ADDITION x—x �_ ~ P.B. 40, PG. 72 N M Q 04 tl-O Y Q I 0 (D _j f O O I Q a tL F.F.EL.= by m Q o ca Q o Qi 21.7' o a- " 15.V Omoo 6 x 10A, Omd ;7 J �' 4' H. C.B.S. WALL w j 10.0' 17.4' hCARPORCH 10.0' 103. \ ASPHALT DRIVEWAY b� OD UTILITY \ 1 Lu 0'7 12.0' 23.4' w a I w yA b' .0' I Ia, N N SE CORNER o°o. o LOT 1 BLOCK 3 b^6 o b o° bti5 375.0' 4' CONC. SIDEWALK 75.00' �✓ F.I.P z 0 F.I.P.Z 0 F.I.P.10 (NOID.) (NOID.) ASPHALT (NOID.) 0 12'PARKWAY APPROACH b N b NE 104th STREET b oL _50' PUBLIC RIGHT-OF-WAY_ _ 18' +I- ASPHALT PAVEMENT bj i i NE. 1aq.,K — - - ------------- ------- --- LOCATION MA�P0•� (NOT TO SCALE), • • - ••• • .. 1.. •_. _ 4 7 i2 '3 9 i0 LL T ' N SCALE: 1" = 20' LEGEND ABBREVIATIONS C A A/C UNIT A/C =AIR CONDITIONER UNIT ELEVATION C.L.F. = CHAIN LINK FENCE Z5 FIRE HYDRANT C.B.S. = CONCRETE BLOCK & STUCCO W❑ METER (WATER) CONC.=CONCRETE PROPERTY LINE 0 = DIAMETER a� UTILITY POLE F.F.EL. = FINISHED FLOOR ELEVATION F.I.P. = FOUND IRON PIPE H = HEIGHT ID. = IDENTIFICATION OIS = OFF SET PG. = PAGE P.B. = PLAT BOOK