BPP-19-1058
=,G E &T�E�'C COt.SC 1 '.b < R ' - SOIL STATEMENT MIAMI SHORES BUILDING & ZONING 10050 NE 2 AVE MIAMI SHORES, FL RE: Proposed New Pool for: 535 NE 95 ST MIAMI, FLORIDA GEOTEC No: SS-190718-101 To whom it may concern, 7/18/2019. A representative of GEOTEC CONSULTING GROUP CORP. has inspected the soil on the pool excavation at the above referenced property. It is our professional opinion that the existing soil inspected meets a bearing capacity of 2,000 psf. GEOTEC CONSULTING GROUP CORP. appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please contact this office. Respectfully submitted GEOTEC CONSULTING GROUP CORP. r� Profession n n�er No. 56712 tate f F1'orida GEOTECHN.'CAL , CIVIL & STRUCTURAL ENGINEERS -13C°3 SW 133 CT. V A`AI , FL 3310 - P: (786) 319.0355 / P: (786) 5-,3-0734 garcia52202bc south.net Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 I MIIIIIII 1 Permit NO.: BPP-05-19-1068 Permit Type: Pools/Whirlpools/Hot Tubs Work Classification: New Permit Status: Approved Issue Date: 07/02/2019 Expiration: 11/06/2019 Location Address Parcel Number 535 NE 95TH ST, Miami Shores, FL 33138 1132060140730 Contacts GARRETT & NAYLA MOFFETT Owner 535 NE 95 ST, MIAMI SHORES, FL 33138 Mobile: 3054092770 GRAY DOLPHIN POOLS & CONSTRUCTION Contractor INC RAONEL LOPEZ 16225 SW 117 ST D14, MIAMI, FL 33177 Business: 3052070606 Description: NEW POOL 4505QFT & CONCRETE DECK 560SQFT Valuation: $ 26,500.00 F ction Requests: 62-4949 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $200.00 CCF $16.20 Certificte of Completion for Single Fam $50.00 and Duplex DBPR Fee $11.93 DCA Fee $7.95 Education Surcharge $5.40 Permit Fee $595.00 Planning and Zoning Review Fee $35.00 Scanning Fee $15.00 Structural Review ($45) $45.00 Technology Fee $19.88 Total: $1,001.36 Payments Date Paid Amt Paid Total Fees $1,001.36 Check # 2460 07/02/2019 $801.36 Check # 37356 05/10/2019 $200.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDW�I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating cQn n d zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date July 02, 2019 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING 7PE IT APPLICATION BUILDING ❑ ELECTRIC ❑ ROOFING Ic I F ���MAY 0 19 ltw FBC 20 Master Permit No. -P 0 S -i 1� - I Vsa Sub Permit No ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑PLUMBING ❑ MECHANICAL [—]PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 6_3 57" y % 9�11 I-eT City: Miami Shores County: Miami Dade zip: 33N3 b Folio/Parcel#: 11" 3Z(6 -o19- 073o Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder),: "N R i L or yq o FFe O- Phone#: 5o,5' Vo J - 2.77V Address: �?J� %V �S S'„<et City: N C*Ytln S\'lUnr S State: F:7C- zip: 33 13k Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: &aA!y &-)L'P4n9R DO/ S `f aw_s��'6"t Phone#: �U� ' Z0-7 -060C Address: I 6 ZZS-_ S LcJ 1 1:7 Aye City: yy �z*m c State: /`Z_ Zip: Qualifier Name: kA-Dye L L V P e:z- Phone#: State Certification or Registration #: C P� �y��sl Certificate of Competency #: DESIGNER: Architect/Engineer: A leymoIto IR4v L L"V E7 Phone#: 7 9 -SC� Address: 133yZ S,.J 15ZM^5 _ City: / r1 G)" Z7 State: FL zip: Value of Work for this Permit: $ 2 .'�_0t7 Square/Linear Footage of Work: 5Z - odL S6o f3eGk Type of Work: ❑ Addition ❑ Alteration New ❑ Repair/Replace ❑ Demolition Description of Work: l) FT Specify color of color thru the: Submittal Fee $_ Scanning Fee $ _ Technology Fee $_ Structural Reviews $ (Revised02/24/2014) Permit Fee $ Radon Fee $ —Training/Education Fee $ CCF $ DBPR $ CO/CC $ Notary $ Double Fee $ Bond $ Sbo.01;3 TOTAL FEE NOW DUE $ a0 i •310 Bonding Cgmpan,„s Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the obsenc%ted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Jdt��— WNER or AGENT The foregoing instrument was acknowledged before me this day of 0(L15L , 20 IJ by ►—rr— 'who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: •, mitinMnu r oummcn Print: °`�'s Notary Public - State of Florida Seal: • +' Commission # GG 046773 zuy a;= My Comm. Expires Nov 14, 2020 ��''�° ��� d'••• Bonded through National Notary Assn. Signatur CONTRACTOR The foregoin instrument was acknowledged before me this Z- day of W61 20 /q by fktwLcz- 'who is personally known to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: as Print: •••• � a HIGMAHU F.JUMMtH Seal: •E Commission N GG 04677J My Comm. Expires Nov 14, °� Bonded through National Notary sssssssssssssssssssssssss sssssssssssasssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssss APPROVED BY L 1 Plans Examiner Zoning Structural Review (Revised02/24/2014) Clerk 4/26/2019 Property Search Application - Miami -Dade County y � Y } OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-014-0730 Property Address: 535 NE 95 ST Miami Shores, FL 33138-2731 Owner GARRETT C MOFFETT NAYLA MOFFETT Mailing Address 535 NE 95 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SO Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 2,152 Sq.Ft Living Area 1,786 Sq.Ft Adjusted Area 1,956 Sq.Ft Lot Size 10,725 Sq.Ft Year Built 1950 Assessment Information Year 2018 2017 2016 Land Value $321,854 $321,854 $267,952 Building Value $165,634 $167,903 $170,172 XF Value $3,672 $3,717 $3,761 Market Value $491,160 $493,474 $441,885 Assessed Value $491,160 $493,474 $435,914 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $5,971 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25.000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 2 PB 10-37 LOT 17 & E1/2 LOT 16 BLK 54 LOT SIZE 75.000 X 143 OR 14535-1914 0590 1 Generated On : 4/26/2019 Taxable Value Information 2018 2017 2016 County Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $441,160 $443,474 $385,914 School Board Exemption Value 1 $25,000 $25,000 $25,000 Taxable Value 1 $466,160 $468,474 $410,914 City Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $441,160 $443,474 $385,914 Regional Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $441,160 $443,474 $385,914 Sales Information Previous Sale Price OR Book -Page Qualification Description 10/24/2016 $635,000 30287-3108 Qual by exam of deed 08/06/2013 $533,300 28763-3650 Qual by exam of deed 05/01/1990 $115,000 14535-1914 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: Mission: Ron DeSantis Governor To protect, promote & improve the health of all people in Florida through integrated state, county & community efforts. �(Df �1Q4't HEALTH Vision : To be the Healthiest State in the Nation Rick Summer (Grey Dolphin Pools) 8050 Grand Canal Drive Miami, FL 33144 RE: Contingency Letter Application Document No: AP1413565 Centrax Permit Number: 13-SC-1948415 OSTDS Number: 535 NE 95 St Miami, FL 33138 Lot:17 i1.1re N May 17, 2019 Subdivision: Miami Shores Sec 2 Dear Applicant: This will acknowledge receipt of an application dated 05/10/2019 for a permit to use an existing onsite sewage treatment and disposal system located on the above referenced property. Reviewed on 5/17/2019 by Loanis Gonzalez. As per your site plan, No objection for New Pool construction. NO BEDROOM ADDITION. From a review of your completed application, it has been determined that your existing system appears to meet the minimum standards of F.A.C. 64E-6 for the proposed use. It is approved for use with the plans submitted to this office. If this system should fail, causing an unsanitary condition to exist, steps must be taken to bring the system into compliance immediately. Department approval of the system does not guarantee satisfactory performance for any specific period of time. Any change in material facts which served as a basis for issuance of this approval requires the applicant to modify the permit application. Such modification may result in this approval being made null and void. Issuance of this approval does not exempt the applicant from compliance with other Federal, State, or Local Permitting required for development of this property. If you have any questions on this matter, please call our office at (786) 315-2454. Sincerely, Loanis Go ale , Engineering Specialist II Florida Department of Health www.FlaridasHealth.com in DADE COUNTY TWITTER:HealthyFLA 1725 NW 167 St, Opa Locka, FL 33056 FACEBOOK:FLDepartmentofHealth PHONE: (305) 623-3500 . FAX: (305) 623-3645 1 YOUTUBE: fldoh s V. STATE OF FLORIDA DEPARTMENT OF BUSINESSxAND-PR4OFE! V =.� ❑ rZr O RICK SCOTT, GOVERNOR CONSTRU THE RESIDENTIAL PROVI IXPIRATIOi+-DE ,UGUSi` 31, 2020 Always verify licenses online at MyFloridaLicense.com Do not alter this document in any form. JONATHAN ZACHEM, SECRETARY AL REGULATION ED UNDER THE This is your license. It is unlawful for anyone other than the licensee to use this document. FI d 002215 Local Business Tax Receipt Miami -Dade County, State of Florida —THIS IS NOT A BILL — DO NOT PAY 4932878 vi�afl BUSINESS NAME/LOCATION RECEIPT NO. EXPIRES GRAY DOLPHIN POOLS & CONSTRUCTION IN(RENEWAL SEPTEMBER 30, 2019 16225 SW 117TH AVE D14 5150313 Must be displayed at place of business MIAMI FL 33177 Pursuant to County Code Chapter SA — Art. 9 & 10 OWNER SEC. TYPE OF BUSINESS PAYMENT RECEIVED GRAY DOLPHIN POOLS & CONSTRUCTION 196 SPECIALTY PLUMBING CONTRACTOR BY TAX COLLECTOR RAONEL LOPEZ QUALIFIER CPC1457551 $75.00 07/11 /2018 CHECK21-18-066101 Worker(s) 3 This local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is not a license, permit, or a certification of the holders qualifications, to do business. Holder must comply with any governmental or nongovernmental regulatory laws and requirements which apply to the business. The RECEIPT NO. above must be displayed on all commercial vehicles — Miami —Dade Code Sec Ba-276. For more information, visit vvvvatr miamidade aovhaxcollector GRAYD-1 OP A1COJRD' CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) V 11102/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsements . PRODUCER 305-262-0086 NAMEACT BRANDON W BUTLER BUTLER, BUCKLEY, DEETS INC. iPHONE 305-262-0086 FAX 305-262-0187 6161 BLUE LAGOON DR., STE 420-.(A/C, No. Ezt): ._ (A/C, No)_ MIAMI, FL 33126 E-rinil6 BBUTLEFt@BB�INS C(�1VI ADDR Brandon W Butler INSURERS AFFORDING COVERAGE NAIC # INSURER A; FCCI COMMERCIAL INSURANCE CO. 33472 INSURED GRAY DOLPHIN POOLS INSURER B CONSTRUCTION INC. 16225 SW 117 AVE STE D14 INSURER C : MIAMI, FL 33177 INSURER D : INSURER E : INSURER F : f"nvGRAfr-Gc CERTIFICATE NI IMRFR• REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. _ INSR TYPE OF INSURANCE DDL UBR POLICY NUMBER POLICY EFF I POLICY EXP LIMITS LTRMMIDDrfYYY A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE._ -.-I $ 1,000,000 - CLAIMS -MADE OCCUR `— GL00197771 06/O3/2018 'i, 06/03/2019 DAMAGE TO RENTED 1 OO,000 n _ � $ 5,000 Mcn_EXP(Any_one arson)_._ _ �— _ PERSONAL & ADV INJURY j $ 1,000,000 GENT AGGREGATE LIMIT APPLIES PER POLICY —1 JECT I LOC X PRO- C J GENERAL AGGREGATE j $ 2,000,000 2,000,000 PRODUCTS COMP/OP AGG $ OTHER: AUTOMOBILE LIABILITY' COMBINED SINGLE LIMIT $ _LEd..tt.C9ldentl. - --- ANY AUTO __BODILY INJURY..jPer..person]_ a._-.-.-_.._.__...---...._.... ........_.. ............. OWNED SCHEDULED AUTOS ONLY AUTOS _BODILY INJURY_(Per acrdent)',...5_ ......... ......._... HIRED NON PNED ............. AUTOS ONLY ............; AUTOS ONLY 'X PROrtRTY DAMAGE (Per accident). ... _._....... $ A X UMBRELLA LIAB I i OCCUR _ EACH OCCURRENCE_____._�`$—_,-,____3,000,000 _. . _ .... _ ....... EXCESS LAB CLAIMS -MADE UMB10001446301 06/0312018 06/03/2019 AGGREGATE $ 3,000,000 — DED RETENTION $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / NI ANY PROPRIETOR/PARTNER/EXECUTIVE 001WC17A76726 11101/2018 11 /01 /2019 X SER TATUTE_ X HRH -- - -- - — - i 1,000,000 E_L,_EACH_ACCI.DENT-__!_$ FFICER/MEMBER EXCLUDED9 Y andatory In NH) t__.._J NIA I 1,000,000 E.L. DISEASE - EA EMPLOYE_ E', $-_....... ........ -.._-.. If yes, describe under DESCRIPTION OF OPERATIONS below ............................._.......__........_.........._............. 1,000,000 E.L. DISEASE - POLICY LIMIT I DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more space Is required) POOL CONTRACTOR, LIC #CPC1457551 f�C�TIC rr-ATC Ue%l MCC rdN(+Fl I ATIr)N MIASHVI SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE MIAMI SHORES VILLAGE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 10050 N E 2 AVE. MIAMI SHORES VILLAGE, FL 33138 AUTHORIZED REPRESENTATIVE ACORD 25 (2016103) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RESTRICTIVE COVENANT PROTECTIVE POOL ENCLOSURE KNOW ALL MEN BY THESE PRESENTS: WHEREAS, the undersigned AAW-04- /i7OFFt7T 1-6-4kneff "f o Fre%l— is/are the fee simple owner(s) of the following described property situated and being in Miami Shores Village, Florida: Address: s3s N q 5 5+tceT mcy}wlc- S ung , r- 3313g Whereas, the undersigned owner(s) kWi-A- n o F e rf {— `i e7r ybl o FFe7T desire to utilize said Lot(s) as a single building site, and the undersigned owner(s) do(es) hereby declare and agree as follows: I. That the property will not be used in violation of any ordinances of Miami Shores Village or Miami -Dade County now in effect or hereinafter enacted. II. That the purpose of the covenant is to induce Miami Shores Village to issue a permit for a pool where the required enclosure is not on the subject property where the pool is located. III. That if any of our adjoining neighbors remove any portion of their fence or wall, or if our/my property shall fail to meet code requirements for pool barriers, we, as owners will immediately installs a protective enclosure to meet code requirements and will obtain a permit for such fence. IV. That, I/we, as owner(s) hold Miami Shores Village harmless for any negligence or injury that results from not having the enclosure. V. If enclosure belongs to said property, I agree to maintain & or replace said enclosure in the event that is damaged or removed by any case. NOW, THEREOF, for good and valuable consideration, the undersigned do(es) hereby declare that he/she will not convey or cause to be conveyed the title to the above property without requiring the successor in title to abide by all terms and conditions set forth herein. FURTHER, the undersigned declare(s) that this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to the above property and shall constitute a covenant running with the land and shall be binding upon the undersigned, his/her successors and assigns and may only be released by Miami Shores Village, or its successors, in accordance of said Village then in 0ff 4 WYK- 'd%VNtAtIGN & PRINT 0 ER SIGN & PRINT I Hereby Certify that on this day personally appeared before me re n sc m &ff y VN(jW J and has produced ID # as identification and he/she acknowledge that he/she executed the foregoing, freely and voluntarily, for purposes there in expressed. SWORN TO AND SUBSCRIBED before me on this ZT day of 2010k SUMMER NO F '' S-J�t>WV@EbfR_0R*pl Florida (Revised 05/2209 .`:- Commission Ar GG 046773 My Comm. Expires Nov 14, 2020 %E OF :d`'� Bonded through National Notary Assn. Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 SWIMMING POOL OWNER'S CERTIFICATION Date Lzr l Miami Shores Village Building & Zoning Department Attention: Building Official I certify that I am the legal owner of the property described as 1VkY�� nio Ff� rr" , located at .5-3 S'- RE 95- SSA«-r fij"c S E,ones .re- 331315 In accordance with Section 33-12(f), Code of Metropolitan Dade County, I certify that I understand and agree that the swimming pool to be constructed at the above address cannot be used or filled with water until separate permit has been obtained for an approved safety barrier, and such barrier erected, inspected and approved. I further understand that this certification, however, does not eliminate the need for obtaining a permit and erecting and approved barrier prior to final inspection and use of the pool. Legal Owner G� Note: This certification is to be submitted with a swimming pool permit application in duplicate. Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 NOTICE OF REQUIREMENTS RESIDENTIAL SWIMMING POOL, SPA AND HOT TUB SAFETY ACT I (We) acknowledge that a new swimming pool, spa or hot tub will be constructed or installed at S3 A) le c% S S`htrr7 Miami Shores, FL, and hereby affirm that one of the following methods will be used to meet the requirements of Chapter 515, Florida Statues and the Florida Building Code R4101.17. Please initial the method(s) to be used: The pool will be equipped with an approved safety pool cover that complies with ASTM F1346-91. (Submit Manufacturer's Specifications). A continuous, one-piece (child) barrier meeting the requirements of Florida Building Code R4101.17.1.15 will protect the pool perimeter. The plans shall show the fence location and method of attachment, including one end that shall not be removable without the aid of tools. (Submit Manufacturer's Specifications). A combination of non -dwelling walls and fences (screen enclosure, child fence, masonry fence walls, chain link or wood fence, etc.) will protect the pool perimeter. The plans must specify the type and location of all non dwelling walls. Florida Building Code, R4101.17.1 Any combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all windows and doors will be equipped with exit alarms complying with Florida Building Code, 7*Any 17.1.9 (Submit Manufacturer's Specifications). combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all doors will be equipped with a self -latching device with positive mechanical latching/locking installed a min. 54" above the threshold. If this option is selected, submit plans showing all types and location of all perimeter protection. The plans must also show the location and type of all openings, and the hardware type for each location. (Submit Manufacturer's Specifications). In accordance with the Code, the pool may not be filled with water without compliance with the Private Swimming Pool Safety Requirements, and upon expiration of the permit, the pool shall be presume nsa and that not having one of the above installed will constitute a vi ion of C f .S ., d will be considered as committing a misdemeanor of the second egree, le -as ' ed in Section 775.082 or Section 775.083 F.S . This form must be signed by nd the prime contractor. � f�l ttl;a-- /) � V4 TOR' GNATURE AND DATE OWNER' SIGNATURE AND DAT CONTRACTOR'S N E (PLEASE PRINT) NER'S NAME (PLEASE PRINT) C ICHARD R SUMMER ICHARD R SUMMER ';;;Y :,;;� s Notary Public -State of Florida � � = Notary Public -State of Florida Commission # GG 046773 • - Commission # GG 046773 My Comm. Expires Nov 14. 2020 y o� My Comm. Expires Nov 14, 2020 Bonded through National Notary Assn. �':;Eo<<�° '� Bonded through National Notary Assn. 5/10/2019 Safe Pool Alarm S187D — Techko Group � ru" u QK Nv Home Shop Contact Us LM41&twy WNIl ;O Ir REMM- M $"rD V-2 M•ziM awt-A `iar" 1r https://techkogroup.com/collections/security-alarms/products/sl87d 1/3 5/10/2019 Safe Pool Alarm S187D — Techko Group • •••••• •••• • ••••• • Safe Pool Alarm S187D $29.99 Quantity 1 ADD 10 CART Techko's S187D Safe Pool Alarm is designed to monitor a gate, door, window or other entryway to you pool area. A high output 110 dB alarm siren sounds when the magnetic contact is broken without pressing the adult bypass button. Two sensors are included so that you can have your sliding glass door open, with your screen door shut, leaving the alarm active. This alarm is always in protective mode and will sound the instant a door, window or gate is opened and will continue until the bypass button is triggered. The S187D is ETL listed and approved under UL 2017 standards. • Meets UL 2017 standards for Child Pool Safety Law https://techkogroup.com/collections/security-alarms/products/s187d 2/3 5/10/2019 Safe Pool Alarm S187D — Techko Group • Includes extra set of sensors and bypass reset button for use on both sliding glass doors and screen doors • Water and weather resistant • High Output 110-115 dB, 6-Tone Alarm. "Always On" Alarm Protection • Low battery LED display ffl SHARE %F TWEET 0 PIN IT BACK TO SECURITY ALARMS •••••� •••••• • • • •••••• 0000 • • •••••• •••• • ••••• •••••• •••• ••••• • • • • as •• •••• •••••• • •••••• • • Privacy Policy Terms of Service go : .....sees, • .. . . •• ••• © 2019, Techko Group Powered by Shopify https://techkogroup.com/collections/security-alarms/products/sl 87d 3/3 DARY SURVEY SCALE = 1:20 LOT 8 BLOCK 54 LOT 7 BLOCK 54 V 1. ................. ...�....................:::: ::..:...:: r�............... .. . .•.���.���..5':�A�SF?H6P.M...................... O O 15 U.E. �..:::::::�.:•:•:•....::::...:.:.:..:...... .. .......:::.... �'........ :::::::::::::: ............... :t.P.X�".1...........................75:40..R&MFJ.... M ........ .; W. M: : I, P.z'................. . m 0. 0' 'J — � 3a I l oti Z < O o n 0 m L'- IT j ED z Z �C1 V7 LL O �� Z v PORTION LOT 16 P4 BLOCK 54 C 'T IDS C r , POOL pppm D PUMP 10.30' s m 13.00 LL O REMAINDER OF � <j LOT 16 BLOCK 54 0 Lq 0 O �(CD:5 �{ W.F.6' J LOT 17 00 BLOCK 54 I -I- I -I I I-36.00'-I L I I -I -I IT__I�J l� IT11-,III-rI-I-11J �L� I T ITITITITITITITITITITIIIIIIITIII -3'. _I ------ IT IT POOL II I I I I 30.00 ; _ III ?-I-I-I-I-I I -I -I -I co 0 q o r� rn p a r O CONC. of 0. a / DO c c 771 21.50' - 12.50' 0 o v 00 LL J O 17.84' C) LL Of LOT 18 O BLOCK 54 Ln N �t • • • • • • • CLIENT: GARRETT MOFFETT AND NAYLA MOFFETT PROPERTY ADDRESS: 535 NE 95 STREET, MIAMI SHORES, e•33 3 • •• ••• •- LffA • E CRIP(fl0N - • - THE BA&T i12.0E OT.16 AND tOT 17, BLOCK 54, MIAMI MOR'OSECTION Ct?JRDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 10, PAGE 37, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA. ELEVATION INFORMATION: BM-W-603-R ELEVATION = 8.06' {29} BASED ON THE FLOOD INSURANCE RATE MAP OF THE FEDERAL EMERGENCY MANAGEMENT AGENCY DATED OR REVISED ON 09-11-09 THE HEREIN DESCRIBED PROPERTY IS SITUATED WITHIN ZONE X BASE FLOOD ELEVATION N/A COMMUNITY 120652 PANEL NUMBER 0306 SUFFIX L EFFECTIVE PANEL DATE 09-11-09 CERTIFIED TO: - GARRETT C AND NAYLA MOFFETT Z _ L o j•}�j j ONE STORY 40.30! _ RES. # 535 FF=11.00' nOti W.F.6' 8.80' GARAGE o PL8.4O' W 10.001 12.90' Ln TILE- 0 0.50' �� Z 2 2. �y � 15.70' 18.00' 12.00' W > Q o I oo� W.F.6' AJ CV O L0 L) L'i W z F-LP Y" 9o. i�, Z' N C) ° F.I.P %z" 175.00, NO 2 2' 3', / / NOID B.coRN a 75.0'0'�(R&M.F) a.. a . Qa. <d 5`. CONC.` SvdK. o .............. .ASPH.. •'• 25.5' PARKWAY o0 C:)............. ............... o ................ ................. .................. ................... ..................... . . .......................................................................................................................... NE 95th STREET .:%% .:...........::::::::::::::: .:.:::::.::....::::::::::::::::::..::::::::...................................................................::;:::::.:.::::.:. .:.:.:.::.:.:.:.: .......................::::.:.:.:..:. ..................... ::.-::::...............:..:.-.:.:..........:.:.:.:.:.:..:.:.:=:.:.:..:.:...:.:.....:.:.:.:.:..:.=:.:.:.:.:.:.:.:...:.... ........................... 20 ASPH PVMT rQ :::::............ (80' TOTAL R/W BY PLAT) ..:� .......... ................................................. LEGEND & ABBREVIATIONS A - ARC. DISTANCE CU.P- CONCRETE UTILITY POLE LM.E-LAKEMAINIENANCE P.O.T.• POINTOFTANGENCY STY. -STORY - OVERHEAD UTILITY LINES A/C- AIR CONDITIONER PAD CP.-CONCRETEPORC/ EASEMENT P.O.C-POINTO' SWK-SIOEWAU( - CONCRETE BLOCK WALL(CB.S) AE.-ANCHOREASEMENT as. CONCRETESLAB '-MINUTES COMMENCEMENT SLP.-SETIRONRPE-*---K--h— - CHAIN LINK FENCE(C.LF) AR.-ALUMIMIMROOF CW-CONCRETE WALL( (M)- ME45UREDdS7MlCE P.O.B-POINT OF BEGINNING S.I.R.-SETWONROD � - IRON FENCE(I.F.) AS-ALUMINUMSHED D.E.-DRAINAGEEASEMENT (MF)-MEASUREDFIELD P.R.C-POINTOFREVERSE SP.-SCfEENEDPORCH _-),y00D FENCE F. ASPH.-ASRLLLT D. M. E- DRAINAGE MAINTENANCE M.E-MAINTENANCE CURVATURE SV.-SEWER VALVE (W ) BG-BLOCKOORNER EASEMENT EASEMENT PWY-PARKWAY '-SECONDS 0� -ELEVATIONS BLDG.-BUIIDVM DRWY-DRASW'AY M.H.-MANHOLE P.R.M.-PERMANENTREFERENCE T- TANGENT B.M.-BENCHMARK DEGREES N.AP.-NOTAPARTOF MONUMENT TWP- TOWNSHIP B. O. B.•BASISOFBEARING ELEV-ELEVATION NGVD- NATIONAL GEODETIC P.LS-PROFESSIONALUND UTL-UTILITY (C)- CALCULATED ENCR.-ENCRWCIMEM VERTCALOATUM SURVEYOR U.E.-UTIUTYEASEMENT CONTACT YOUR PROCESSOR CB.-CATCRBASN' F.N.-RREHYDRANT N. T.S-NOT TO SCALE P.P.-POWER POLE U.P.-UTLRYFC.E CBS-CONCRETEBLOC( F.I.P.-FOUND IRONRPE Nor NO. -DUMBER P.U.E.-PUDLICUTIUTY W.M.-WATER METER STRUCTURE F.I. R. FOUND IRON ROD 0/S-OFFSET EASEMENT W.F.-WOODFENCE CBW-CONCRETEBLOC( WALL F.F.E.-RMSHEDROOR O.H.-OVERHEAD W.P.-WOODPORCR C • O CH. -CHORD ELEVATON O.H.L-OVERHEAD UTWiYLWES (R)-RECORD CSTANCE W. R.•WDOD ROOF ORB. -CHORD BEARING F.N.O-FOUNDNAIL&DISK O.R.B.- OFFICIAL RECORDS BOOK R.R.-RA0. ROAD W.V.-WATERVALVE ORL-CHOROLENGTH FT -FEET O.V.H.-OVERHANG RES-RESIDENCE M-MONUMENTLINE CL-CLEAR FNIP.- FEDERAL NATIONAL PVMT-PAVEMENT R/W-RIGHTOfWAY T- CENTERLINE -- C.O.-CLEAN OUT INSURANCE PROGRAM PL.-PLANTER RAD. - RADIUS OR RADIAL B - DELTA CLF-CHAIN LINK FENCE F.N.-FOUNDNAIL P.L.-PROPERTYLWE RGE.-RANGE I-PROPERTYUNE CM.E- CANAL MAINTENANCE INAEG.- INGRESS AND EGRESS P.CC-POINTOFCOMPOUND R.O.E.-ROOF OVERHANG O EASEMENT EASEMENT CURVATURE EASEMENT CONC-CONCRETE LP.-UGHTPOLE P.C.-POINTCFCORVATURE SEC -SECTION L F.E. - LOWEST FLOOR ELEVATION LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY: • IHLRE MAYBE EASL,-1 RECORDED /N THE PU&JC RECORDS NOT SHOWN ON TFYS SURVEY. DRAWN BY. NH •EXAMINATIONSOFTHEABSTRACT OF THE WLL HAVE TO BE MADE TO DETERMINE RECORDEDINSTRUMENTS, IFANY, AFFECTING TE PROPERTY. .THIS SURVEYIS SUBJECT TO DEDICATIONS, LIMITATIONS. RESTRICTIONS. RESERVATIONS OR EASEMENTS OF RECORD. • LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY. • BOUNDARY SURVEY MEANS A DRAWING AACV OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN THE FIELD, COULD BE DRAWN AT A SHOWN SCALE ANDOR NOT TO SCALE. CHECKED BY. FA :THETERM%,AC AS OACHM0VVr MMARE ENSVISIBOE UNLESS �BSOVVEDEPICTED PGRO °�E ENCROACHMENTS. • ARCMTECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS, SETBACKS AND WILL BE RESPONSIBLE FOR SUBMITTING • PLOT PLANS WITH CORRECT INFORMATION FOR'APPROVAL FOR AUTHOR/ZATON' TO THE PROPER AUTMJPoTES IN NEW SCALE: 1 '= 20' CONSTRUCTION • UNLESS OTEAW%E NOTED. THIS FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING ANDMR FOUNDATIONS. • F—CE OWNERSHIP NOT DETERMINED. :TDOES SPLAN OF SURVEY HAS SEENPDPAAED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED HEREON, THECERTFICATE FIELD DATE: 10-31-2019 • ELEVATION DATUM USED NGVD 1929 • SURVEYOR' S NOTES: JOB NO: 19-68301 1.CZRTIFICATEOF AUTHORIZATION LB#7538. NOT VAUD WTHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL, 2. LYE—WrW RESRAYSIBLEFORANYOISTANCE. ANGLE. OR ELEVATIONS TAKEFROM IRIS OMWWG FOR ANYPURFOSEOF OESIGNOR SHEET: 1 OF 1 LGD`"— SURVEYOR NOTE - THERE ARE NO VISIBLE ENCROACHMENTS NOTE -BEFORE ANY CONSTRUCTION THE SETBACKS MUST BE CHECKED THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY. LOCATION SKETCH SCALE = N.T.S. Lu z 0 0 W 0 0 O O O Q 54 L LIJ po Z �2 v ao m 0 0 0 0 0 0 NE 95th STREET D'AVILA & Associates ,Services, Inc. an rwyore Enginsen CERTIFICATE OF AUTHORIZATION NO. 28056 CERTIFICATE OF AUTHORIZATION NO, 7538 14750 NW 77 CT SUITE 204 MIA I LA ES FL33016 P NE:( 5)b53-2600 BY. FRANCISCO A AGUIRRE P.E., P.L.S. (10-31-2019) PROFESSIONAL LAND SURVEYOR NO.: 3354 STATE D£ FLOMDA (VALID COPIES OF THIS SURVEY WILL BEAR THE EMBOSSED TEAL OF THEATTESTING LAND SURVEYOR). SURVEYOR'S CERTIFICATION: I HEREBY CERTIFY TO: THAT THE ATTACHED BOUNDARY -SURVEY OF THE ABOVE DESCRIBED PROPERTY, IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF, AS RECENTLY SURVEYED AND PLOTTED UNDER MY RESPONSIBLE DIRECTION, AND THAT THERE ARE NO ABOVEGROUND ENCROACHMENTS UNLESS SHOWN THEREON. I FURTHER CERTIFY THIS SURVEY MEETS THE STANDARDS -OF -PRACTICE FOR BOUNDARY -SURVEYS, PURSUANT TO SECTION 472.027, FLORIDA STATUTES, AND ADOPTED IN CHAPTER 5J-17.050, FLORIDA ADMINISTRATIVE CODE. EFFECTIVE DATE JANUARY 1, 2010; AS AMENDED FEBRUARY 23, 2005. Ito j A� MOST A I T 1 TIME ff 1 LOT 7 BLOCK 54 ........................ $:.5' : ASPH�PYM7 . . . o O 15. U,E.... In .. M .. �'......... . ....... ................... ..P.y".1 75.40 R&MF:} „-- N U�iuP D > 'L > z Z (� O u m o < o m m zo 3 c 7 �G v cf)) m ` Z v < c m O N__m D LU z W Q L / ui 0 M O tK Lo PO TION OF L T16 BL CK 54 POOL PUMP 10.30' • • Y�l I 13.00 E REMAINDER OF 2 ro LOT 16 06 BLOCK 54 0 u� o 0 � (0 W.F.6'-) 8.80' GARAGE 10.00' 12.90' h 2 2. O U N N `90• 175.00' F.I.P Y" NO 2' 2' B.CORN < a �{ W.F.6'J LOT 17 00 BLOCK 54 1 -'I—I—I I I I I-36.00'T II —I —I I- I _I—T—I T�I�I�1='I��I-I-l�T�Tll�l�lll III�T�I�T�I- 11 —IIiII I� II 0 POOL � �I I II j 30.00, ' �o 0 0 Dj N 0 Vj �� LL CO ADO 0 o ro CONC. d CO ° a a � 21.50' oo Ty- 17 84' 12.50' ONE STORY RES. # 535 FF=11.00' I-1-1 C) N o ti o j N rri 70' 18.0 12.00' 0� W.F.6' O /LiJ N ^M d 75.(YO'°(R&M.F) a.. a Ad • .• ••• • • . ••• ... . ...... . ...... • Is . . . Is % • .... •• •• •• • • •• • • ...... ... . ..... CLIENT: GARRETT MOFFETT AND NAYLA MOFFETT PROPERTY ADDRESS: 535 NE 95 STREET, MIAMI SHORES, r GAA JDEISOR/FTIOAk • • • THE EA T;1/2 CV60116 ANCCLOT 17, BLOCK 54, MIAMI *SHORES SEtTI6N*M8,•A000RDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 10, PAGE 37, OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA. ELEVATION INFORMATION: BM-W-603-R ELEVATION = 8.06' {29} BASED ON THE FLOOD INSURANCE RATE MAP OF THE FEDERAL EMERGENCY MANAGEMENT AGENCY DATED OR REVISED ON 09-11-09 THE HEREIN DESCRIBED PROPERTY IS SITUATED WITHIN ZONE X BASE FLOOD ELEVATION N/A COMMUNITY 120652 PANEL NUMBER 0306 SUFFIX L EFFECTIVE PANEL DATE 09-11-09 W q CERTIFIED TO: GARRETT C AND NAYLA MOFFETT J C� GIo M--I IV M V 2 SURVEYOR NOTE ct LOT 18 - THERE ARE NO VISIBLE ENCROACHMENTS BLOCK 54 Lo NOTE N -BEFORE ANY CONSTRUCTION THE SET BACKS v MUST BE CHECKED THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY. F.I.P Y" NOID .r5'. CONC' SWK LEGEND & ABBREVIATIONS A -ARC DISTANCE CU.P.- CONCRETE URU7YFOLE L.M.E.- LAKE MAINTENANCE P.O.T.-POINTOFTADENCY STY. -STORY • OVERHEAD UTILITY LINES AYC- AIR CONDITIONER PAD CP.-LCNCRETEW4CH EASEMENT P.O.C-FCIATOF SWK.-SIDEWALK - CONCRETE BLOCK WALL(GB.S) AE-ANCHOREASEMENT CS-CONCRETESIAB '-MMTE5 COMMENCEMENT S.I.R-SETRroNPK -K— ---Ir— - CHAIN LINK FENCE(C.LF) AR. -ALUMINUM ROC- CW-CONCRETEWALK (I - MEASURED DISTANCE P.O.B.-POINTOF BEGIfWING SI.R.-SETIRCNROD �— � IRON FENCE(I.F.) AS.-ALUMINUMSHED DE.-DRANAGEEASEMENT (MF)-MEASURED FlCD P.R.C.-POINT OFREVERSE SP.-SCREENEDHMCH _ � WOOD FENCE (WF. ) AS .-ASPHALT B.C.-BLOCK CORNER D.M.E.- DRAINAGE MAINTENANCE EASEMENT M.E.-MAINTENANCE EASEMENT CURVATURE S.V.-SEWER VALVE PWY-PARKWAY '-SECONDS p,y>• �ELEVATTONS BLOG.-BUILDING DRWV-DRIVEWAY M.H. - MANHOLE P.R.M.- PERMANENT REFERENCE T.TANGENT B.M.-BENCHMARK -- DEGREES N.A.P.-NOT APART OF MONUMENT TAP -TOWNSHIP B.O.B.-BASIS OFBEARING ELEV-ELEVATION NGVD- NARONAL GEODETIC PLS-PROFESSIONALI/JND UTIL-U71UN CONTACT YOUR PROCESSOR (C)-CALCULATED ENCR.-ENCROACHMENT VERTICAL DATUM SURVEYOR U.E.-UDLINEASEMENr B.- CATCIISASH. CW F. -FIRE HYDRANT N.T.S.-NOT TO SCALE PP.-P0IVERPOLE UP.-UTILITYPOLE CBS -CONCRETE BLOCK FIP.-FOUDIRONRPE Hor NO. -NUMBER P.UE-PVBLICURUN W.M.-WATER METER STRUCTURE F.I.R.-FOUDWONROD 0/S-OFFSET EASEMENT W.F.-WOOD FENCE E� CB.W-CONCRETEBLOO( WALL FFE-RMSHEDFLOOR O.H.-OVERHEAD W.P.-WOODFORCi Q • O CH. -CHORD ELEVATION O.RL- OVERHEAD UnUTYUMSS (R)-RECORDOIST.WOF W.R.-WOOD ROOF CKS.-CHORD BEARING F.N.D.-FOUND NAIL 6 DISK OR OFFICIAL RECORDS BOOK R.R.-RAILROAD W.V.-WATER VALVE CHL-CHORD LENGTH FT -FEET O.VH.-OVERlANG RES-RESIDENCE M-MONUMENTUNE CL-CLEAR FMP.-FEDERAL NADONAL MMT.-PAVEMENT -- R/W-RIGHWAY c- CENTERLINE T-0FRADIUS C0.-EAN COUT CLF-CHAN LINK FENCE INSURANCE PROGRAM F.N-FOUD HAIL PL.-PLANTER P.L-PROPERTYUNE FAD.- OR RADIAL B-DELTA RGE.-RANGE l-PROPERTYUNE CM.E- CANAL MAINTENANCE INSEG.-INGRESSAND EGRESS P.C.C.- POINT OF COMPOUND R.O.E.-ROOF OVERHANG EASEMENT EASEMENT CURVATURE EASEMENT CONC-CONCRETE L.P.-LIGHTFOLE P.C.- POINTOFCURVATURE SEC. -SECTION LFE- LO WESTFLOCR ELEVARON LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY: • 7HthE MAY bE EAS�:.iNTS itECOROED IN THE PUBUC RECORDS NOT SDV✓NONTHIS SURVEY. DRAWN BY. NH • EXAMINA77ONS OF THE ASS ACT OF 77TLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IFANY, AFFEC7 MG THE PROPERTY. • THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORD. • LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESPNG TITLE COMPANY. • BOUNDARY SURVEY M-AA5 A DRAVWNO ANDIOR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN THE FIELD, COULD BE DRAWN A TA SHOWN SCALE ANDOR NOT TO SCALE. CHECKED BY: FA :rTHEi RMT•SENCRO CHMENT'MEANS VISIBLE AND ABOVE GKW ARE PER PLAT BOOK. UNLESS ROUND TED TENCROACHMENTS. • ARCHITECTS SHALL VERIFYZOMNG REGULATIONS, RESTRICTIONS, SETBACKS AND WILL BE RESPONSIBLE FOR SUBMITTING • PLOT PLANS WITH CORRECT INFORMATION FOR -APPROVAL FOR AUTHORIZATION TO THE PROPER AUTHORITIES INNEW SCALE: 1I'= 20' CONSTRUCTION. • UNLESS OTHERWISE NOTED, THIS FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING ANDOR FOUNDATIONS. • FENCE OWNERSHIP NOT DETERMINED. FIELD DATE: 10-31-2019 :TOEPLAN S NOTOEXTENSURVEY. ANY UNNAMED PARTY. THE EXCLUSIVE USE OF THE ENTITIES NAMED HEREON THE CERTIFICATE • ELEVATION DATUM USED NGVD 1929 JOB NO: (� 19-68301 • SURVEYOR'S NOTES: 1.CERTIFICATEOFAUTHORfZATION LBI7538. NOT VAUD WITHOUT AN AUTHENTICATED ELECTRONIC SIGNATURE AD - AUTHENTICATED ELECTRONIC SEAL 3. IVE N1LL NOT BE REEPCMBLEFORN/YObTAACE AAGIE OH ELEVATpNS TMEFROM THIS dU1MYG FORANYPWNBE OF DESXTROR SHEET. • 1 OF 1 —pow LOCATION SKETCH SCALE = N.T.S. Lu m m n D 0 0 0 0 0 0 0 W Q 54 Lu z 0 NE 95th STREET D'AVI LA & Associates Services, Inc. —Molli Surveyors k Engineers CERTIFICATE OF AUTHORIZATION NO. 29056 CERTIFICATE OF AUTHORIZATION NO. 7538 14750 NW 77 CT SUITE 204 MIAMI LAKES, FL 33016 PHONE:( 5)953-26M BY. FRANCISCO A AGUIRRE P.E., P.L.S.-31-2019J PROFESSIONALUINDSURVEYORNO: 3354 STATEOFFLOR/DA (VALID COPIES OF THIS SURVEY WILL BEAR THE EMBOSSED SEAL OFTHEATTESTING LAND SURVEYOR). SURVEYOR'S CERTIFICATION: I HEREBY CERTIFY TO: THAT THE ATTACHED BOUNDARY -SURVEY OF THE ABOVE DESCRIBED PROPERTY, IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF, AS RECENTLY SURVEYED AND PLOTTED UNDER MY RESPONSIBLE DIRECTION, AND THAT THERE ARE NO ABOVEGROUND ENCROACHMENTS UNLESS SHOWN THEREON. I FURTHER CERTIFY THIS SURVEY MEETS THE STANDARDS -OF -PRACTICE FOR BOUNDARY -SURVEYS, PURSUANT TO SECTION 472.027, FLORIDA STATUTES, AND ADOPTED IN CHAPTER 5J-17.050, FLORIDA ADMINISTRATIVE CODE. EFFECTIVE DATE JANUARY 1, 2010; AS AMENDED FEBRUARY 23, 2005. M BOUNDARY SURVEY LEGEND $ ABBREVIATIONS SURVEYOR NOTE - THERE ARE NO VISIBLE ENCROACHMENTS AI n TC -BEFORE ANY CONSTRUCTION THE SETBACKS MUST BE CHECKED THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY. W z B.CORN LOT 9 BLOCK 54 SCALE = 1:20 LOT 8 BLOCK 54 A - ARC. DISTANCE P.O.B.- POINTOF BEGINNING A/C - AIR CONDITIONER PAD P.R.C.- POINT OF REVERSE A.E.- ANCHOR EASEMENT CURVATURE A.R.- ALUMINUM ROOF PWY- PARKWAY A.S.-ALUMINUM SHED P.R.M.- PERMANENT REFERENCE ASPH.-ASPHALT MONUMENT B.C.- BLOCK CORNER ALS.- PROFESSIONAL LAND BLDG.- BUILDING SURVEYOR B.M.- BENCHMARK P.P.- POWER POLE B.O.B.-BASIS OF BEARING P.U.E.- PUBLIC UTILITY EASEMENT (C) - CALCULATED C.B.- CATCH BASIN (R)- RECORD DISTANCE C.B.S.-CONCRETE BLOCK R.R.- RAILROAD STRUCTURE RES.- RESIDENCE C.B. W.- CONCRETE BLOCK WALL R/W - RIGHT-OF-WAY LOT 7 CH.- CHORD RAD.- RADIUS OR RADIAL CH.B.- CHORD BEARING RGE.- RANGE BLOCK 54 CH.L-CHORD LENGTH R.O.E.-ROOF OVERHANG EASEMENT CL- CLEAR SEC.- SECTION C.O.- CLEAN OUT STY.- STORY CLF.-CHAIN LINK FENCE SWK.-SIDEWALK CM. E- CANAL MAINTENANCE S.I.P.-SET IRON PIPE EASEMENT CONC.-CONCRETE S.I.R.- SET IRON ROD S.P.-SCREENED PORCH C.U.P.- CONCRETE UTILITY POLE S.V.-SEWER VALVE C.P.-CONCRETE PORCH '-SECONDS ,. 1... C.S.-CONCRETESLAB T-TANGENT .....':.5r'.'ASPH'.'r'YMT'...'.'.'..'.'_'.'.'.'.'.•.'.'.'.'.'.'.•.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'.'. 15' U;E.; C.W.-CONCRETE WALK TWP- TOWNSHIP ,4f D.E.- DRAINAGE EASEMENT •UTIL- UTILITY • •7D.M.E.- DRAINAGE MAINTENANCE AUTILITY EASEMENT �j. • Y n —n n C.L.F.4' n oy ti1 I ti Qi�X X O x I co O I'7 II `T O 0 U I l PORTION OF LOT 17 LOT 16 x BLOCK 54 C BLOCK 54 I a; $ I 0.50x3' 10.30' 215' CBS WALL 13.00 O ° O O e CONC. a DO a REMAINDER OF 2 I 21.50' LOT 16 o BLOCK 54 LO O 17.84' O 0 12.50' ONE STORY 0.30' L RES. # 535 x C. L. F.0 � o I o c6 o T� In 18.40' 10.00 112.90'2 18.00' .7o' 12.00' 715 C.L.F.4' 0 CV rp 17O Lri CV90• ! 175.00' J 'tom" e LOCATION SKETCH SCALE =N.T.S. NE 951h STREET EASEMENT • d111LITY POLE DRWY - DR%WAI• • • W. -I WATER ME1ER • • • • - DEGRE 1. • • • .Vg #WD FENCE • ELEV- E f� • Wa.-`VOOD PORCH • ENCR.- ENCR RIL�JT • •W.R.-OVOOD ROCW0 • • • F.H.-FIRSHI(Wi1f• W.V.-WATER VALVE FI.P.- FOUND IRON PIPE t - MONUMENKINE D.50' F.LR.- FOUN!! IIII&MOD • T; CENTER LINO • • • • F.F.E.- FiNtUEpD�fLOSR ELEVATIQN• • .4 f QELTA F.N.1•'�,IF • D.- FOURDM{IP& DISK • ( - PROPERTY j i • • • FT-FEQ• • •• • • FNIP.- FEDER&L NAT)NAL • • • • • • • • • INSURANOF M ROQRqlM • • • • • • F.N.- FOUND NAIL *Soso. • OVERHEAD UTILITY LINES IN.&EG.- A" -%AND EGRESS • • CONCRETE BLOCK WALL EASEME.1 • • • —�� • CHAIN LINK FENCE LP.- L HT POLE • • • • • • • • —e—e— • IRON FENCE LF.E.- LQWEST FISOOR ELEVAT!" • • • • •WOODFENCE LM.E.-VIKEAMIrNVNANCE • • 0 • EXISTING ELEVATIONS • EASEMENT* • • 0000• • ' - MINUTES • • • • • • (M)- MEASURED DISTANCE see* M.E.- MAINTENANCE EASEMENT CONTACT YOUR PROCESSOR M.H. MANHOLE N.A.P.- NOT A PART OF NGVD - NATIONAL GEODETIC • VERTICAL DATUM N. T.S.- NOT TO SCALE N or NO.- NUMBER ( O/S - OFFSET O.H.- OVERHEAD O.H.L.- OVERHEAD UTILITY LINES O.R.B.- OFFICIAL RECORDS BOOK O.V.H.- OVERHANG PVMT- PAVEMENT PL- PLANTER P.L- PROPERTY LINE P.C.C.- POINT OFCOMPOUND CURVATURE P.C.- POINT OF CURVATURE P.O.T.- POINT OF TANGENCY P.O.C.- POINT OF COMMENCEMENT � LOT 18 0 BLOCK 54 Ln cV CLIENT: GARRET MOFFETT AND NAYLA MOFFETT PROPERTY ADDRESS: 535 NE 95 STREET, MIAMI SHORES FL 33138 LEGAL DESCRIPTION: THE EAST 2 OF LOT 16 AND ALL LOT 17, BLOCK 54, MIAMI SHORES SECTION TWO, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 10, PAGE 37, OF THE PUBLIC RECORDS OF MIAMI DADE COUNTY, FLORIDA. ELEVATION INFORMATION: B.M. USED ------ ELEVATIONS ------ LOCATED ----------- BASED ON THE FLOOD INSURANCE RATE MAP OF THE 0.50' FEDERAL EMERGENCY MANAGEMENT AGENCY DATED OR REVISED ON 09-11-2009 THE HEREIN DESCRIBED PROPERTY IS SITUATED WITHIN ZONE X BASE FLOOD ELEVATION NIA COMMUNITY 120652 PANEL NUMBER 0306 SUFFIX L EFFECTIVE PANEL DATE 09-11-2009 CERTIFIED TO: GARRET MOFFETT AND NAYLA MOFFETT OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY VIVIAN R. RIVEIRO, P.A WELLS FARGO BANK, N.A; ISAOA I ATIMA Know what's below. Cali f& before you dig. LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY: • THERE MAYBE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY . EXAMINATIONS OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFECTING THE PROPERTY • THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORD • LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLECOMPANY • BOUNDARY SURVEY MEANS A DRAWING AND70R A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN THE FIELD, COULD BE DRAWN AT A SHOWN SCALE AND/OR NOT TO SCALE • EASEMENTS AS SHOWN ARE PER PLAT BOOK, UNLESS DEPICTED OTHERWISE • THE TERM"ENCROACHMENT'MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS • ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS, SETBACKS AND WILL BE RESPONSIBLE FOR SUBMITTING • PLOT PLANS WITH CORRECT INFORMATION FOR'APPROVAL FOR AUTHORIZATION' TO THE PROPER AUTHORITIES IN NEW CONSTRUCTION • UNLESS OTHERWISE NOTED, THIS FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING ANCHOR FOUNDATIONS. • FENCE OWNERSHIP NOT DETERMINED THIS PLAN OF SURVEY, HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED HEREON, THE CERTIFICATE • DOES NOT EXTEND TO ANY UNNAMED PARTY. SURVEYOR'S NOTES: 1 CERTIFICATE OF AUTHORIZATION LB N 7538 NOT VALID WITHOUTAN AUTHENTICATED ELECTRONIC SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL. 2.THIS SURVEY IS INTENDED FOR NEW PURCHASE„ MORTGAGE OR REFINANCE PURPOSE ONLY; EXCLUSIVELY FOR THIS USE BY THOSE TO WHOM IT CERTIFIES, THIS SURVEY IS NOT TO BE USED FOR CONSTRUCTION, PERMITTING, DESIGN, OR CFd l ANY OTHER USE WITHOUT THE WRITTEN CONSENT OF EFRAIN C LOPEZ BY: Ws'AV I LA ociales Services, Inc. Land Surveyors do Engineers CERTIFICATE OF AUTHORIZATION NO. 29056 CERTIFICATE OF AUTHORIZATION NO. 7538 14750 NW 77 CT SUITE 204 MIAMI LAKES, FL 33016 � VPHONE:(305)95 -2600 -1 L." EFRAIN C. LOPEZ., P.L.S. (09-26-2016) PROFESSIONAL LAND SURVEYOR NO.. 2300 STATE OF FLORMA (VALID COPIES OF THIS SURVEY WILL BEAR THE EMBOSSED SEAL OF THE ATTESTING LAND SURVEYOR). SURVEYOR'S CERTIFICATION: I HEREBY CERTIFY TO. THAT THE ATTACHED BOUNDARY -SURVEY OF THE ABOVE DESCRIBED PROPERTY, IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF, AS RECENTLY SURVEYED AND PLOTTED UNDER MY RESPONSIBLE DIRECTION, AND THAT THERE ARE NO ABOVEGROUND ENCROACHMENTS UNLESS SHOWN THEREON. I FURTHER CERTIFY THIS SURVEY MEETS THE STANDARDS -OF -PRACTICE FOR BOUNDARY -SURVEYS, PURSUANT TO SECTION 472.027, FLORIDA STATUTES, AND ADOPTED IN CHAPTER 5J-17.050, FLORIDA ADMINISTRATIVE CODE. EFFECTIVE DATE JANUARY 1, 20101 AS AMENDED FEBRUARY 23, 2005.