Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MC-19-2921
Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Permit No.: MC-12-19-2921 Q _r.. I-) , l} Permit Type: Mechanical - Residential 1- m om Work Classification: A/C Replacement Permit Status: Approved Issue Date:12/11/2019 l Expiration: 06/08/2020 Parcel Number 83 NE 103RD ST, Miami Shores, FL 33138 1121360130980 Contacts Jeffrey Yao Owner 83 103 THERMAL CONCEPTS INC Contractor LAWRENCE DAVID MAURER 2201 College Avenue, Davie, FL 33317 Business:9544724465 cburghardt@thermalconcepts.com Description: EXACT REPLACEMNT OF 3.5 -TON AIR Valuation: $ 5,228.38 Inspection Requests: CONDITIONING SYSTEM TotalSq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $3.60 DBPR Fee $2.74 DCA Fee $2.00 Education Surcharge $1.20 Permit Fee $132.99 Scanning Fee $3.00 Technology Fee $4.57 Total: $200.10 Payments Date Paid Amt Paid Total Fees $200.10 Credit Card 12/11/2019 $200.10 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating co tr nand ing. Futher re, I authorize the above named contractor to do the work stated. Authorizej Signature: Owner / Applicant / Contractor / Agent Date December 11, 2019 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑ ROOFING Master Permit No. Sub Permit No. ❑ REVISION ❑ EXTENSION [:]RENEWAL ❑PLUMBING 0 MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR r DRAWINGS JOB ADDRESS: Jeffrey Yao SS `O3 R� City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11-2136-013-0980 Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Address: 83 NE 103rd Street City: Miami Shores Tenant/Lessee Name: N/A Email: JEFFREY J YAO &W VIVIENNE YAO phone#: (305)495-7544 State: FL Zip: 33138 Phone#: CONTRACTOR: Company Name: Thermal Concepts, Inc. Phone#: (954)472-4465 Address: 2201 College Ave City. Davie State: FL Zip: 33317 Qualifier Name: Lawrence D. Maurer Phone#: (954)475-4465 ext 268 State Certification or Registration #: CAC039621 Certificate of Competency #: DESIGNER: Architect/Engineer: N/A Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 5,228.38 Square/Linear Footage of Work: Type of Work: ❑ Addition ❑■ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of work: Exact replacement of 3.5-ton air conditioning system. Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ 2LO. 1 6&4 (Revised02/24/2014) Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and: zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. J7� 7 Signature Signature kwyGr AGENT CONTRACTOR The foregoing instrulnt was acknowledged before me this The foregoing instr t was acknowledged before me this 1 day of ece &A, 120 if by 10 day of I G 20 /� by to ho is personally known to Lawrence D. Maurer who is personally known to me o who has produce me or who has produced SELF as "' identification and who d o4tWLJOYDALEYBURGHARDT identification and who did take an oath. ' <= Notary Public - State of Florida NOTARY PUBLIC: d Commission # GG 359 NOTARY PUBLIC: My C m. Expires Jun , 2020 Sign: Sign. Print ON -Print: M. Seal: Seal: v"i� •.• HEATHER mlCHELLE ROSE ,F • `:. Notary Public - State of Florida �� Commission # GG 357484 .•••• OF OF- My Comm. Expires Jul 22, 2023 Bonded through National Notary Assn. *********************** ********* ******* alans Zoning APPROVED BY Examiner Structural Review Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax:(305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): 83 NE 103rd Street City: Miami Shores Village County: Miami Dade Zip Code: 33138 ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED Change disconnecting means: YES* NO ❑ ARHI Sheet Attached: YES ❑E NO ❑ Contract Attached: YES ❑■ UNIT BEING REPLACED DATA NEW UNIT RHEEM MANUFACTURER RHEEM RHC048 AHU or PKG. UNIT MODEL # RHIT4821STA RAMA-042JA2 CON D. UNIT MODEL # RA1442 10 KW HEAT 10 10 3.5 NOM TONS 3.5 3.5 tMtl) 60 CU 30 PKG 1) M.C.A AHU 60 CU 30 PKG AHU 50 C9) 40 PKG 2) M.O.P AHU 50 CU 40 PKG AHU Cu PKG 3) VOLTS 208 / 230 AHU CU PKG PKG UNIT / / PKG UNIT EER/fC1TD 15.00 YES NO REPLACING DUCTS YES YES NO REPLACING THERMOSTAT ES NO YES ® NEW 4"CONCRETE SLAB YES YES ® NEW ROOF STAND YES YES 4D NEW RETURN PLENUM BOX YES 4-M> 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: Contractor's Company Name: State Certificate or Signature a ■ 1: FUSES 40 AMP 3,pepts, Inc. 1 BREAKER 60 Phone: (954)472-4465 Certificate of Competency No. Date: 12/10/2019 (Revised02/24/2014) Cs; T H E H M A I C O N C E P T S II VAC Refrigeration Diet twork CAC039621 CSC046951 CGCA07936 RESIDENTIAL SERVICES Stuart Office Main Office Gulf Coast Office 2497 SE Dixie Highway 2201 College Avenue 8270 Woodland Center Blvd. Stuart, Florida 34997 Davie, Florida 33317 Tampa, Florida 33614 0: 772.220.2365 0: 954.472.4465 0: 727.914.8530 F: 772.220.2273 F: 954.370.6410 F: 727.914.8362 DATE: December 4, 2019 CLIENT: PROPOSAL: 00028376 Jeff Yao Jeff Yao Residence 83 NE 103 rd St Miami Shores, F133138 .......................................................................................................................... Phone: 305-495-7544 Email: -- 83 NE 103rd St Miami Shores Fla 33138 CONTACT: We hereby propose to furnish material and labor, complete in accordance with specifications below for the sum of Five Thousand Two Hundred Twenty -Eight And 38/100 Dollars. • BID#28376 • Provide labor and material to replace existing 3.5 ton air conditioning system at the above location. to Installation of new Rheem 3.5 Ton system with an SEER of 15.00 • RHEEM M/N# RA1442 Condenser and AHU #RH1T4821STANJA with 10 KW heater. • Installation of new air handler unit located in the attic shall have an new emergency drain pan and float switch under unit. • Replace thermostat with new digital non programmable • Reconnect to existing refrigerant lines. • Reconnect to existing ductwork and check for any air leaks and seal any air leaks found included. • Replace condenser unit with exact replacement unit on existing slab. • Secure new condenser to existing concrete slab. • Flush existing refrigerant lines prior to connecting to new equipment connections. • Work to be done during normal working hours Monday through Friday. TOTAL BID: (Five Thousand Two Hundred Twenty -Eight And 38/100 Dollars) $5,228.38 Payment to be made as follows: Acceptance of Proposal This proposal may be withdrawn if not accepted by. The above prices, specifications and conditions are satisfactory and are hereby D4 5e� THERMAL STANDARD TERMS, CONDITIONS AND EXCLUSIONS ARE PART OF THIS PROPOSAL. Customer Initial --on Air I General Data/Electrical Data "0 RA14 Series L U Physical Data PHYSICAL DATA Model No. RA1418A RA1424A RA1430A I RA1436A RA14 2 j 0 '1449 A Nominal Tonnage 1.5 2.0 2.5 3.0 3. '10.0 .5 Valve Connections Liquid Line O.D. - in. 3/8 3/8 3/8 3/8 3/ /8 W 48 Suction Line O.D. - in. 3/4 3/4 3/4 3/4 7/8-,, ' 7/ Refrigerant (R410A) furnished oz.' 68 72 93 112 11 10 1 Compressor Type Scroll ! g• - Outdoor Coil F ti Net face area - Outer Coil 9.1 11.1 12.1 14.8 16. 18.9 2r5 Net face area - Inner Coil - - - - - - - Tube diameter -in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 Fins per inch 20 20 20 20 20 20 20 Outdoor Fan Diameter - in. 20 20 20 24 26 26 26 Number of blades 2 2 2 3 2 2 3 Motor hp 1/10 1/8 1/5 1/6 1/5 1/10 1/5 CFM 2225 2505 2605 3105 4265 4265 4140 RPM 1075 1070 1075 850 820 820 850 watts 130 163 1 142 1 173 1 240 1 236 1 255 Shipping weight - lbs. 125 125 1 148 157 1 199 1 200 1 210 Operating weight - lbs. 122 125 141 150 192 192 202 Electrical Data 10 Line Voltage Data (Volts -Phase -Hz) 208/230-1-60 208/230-1.60 208/230-1-60 208/230-1.60 208/2 0-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection (amps)2 20 25 25 30 40 45 50 Minimum circuit ampacity3 13 15 17 19 30 26 40 Compressor Rated load amps 9.7 11.2 12.8 1 14.1 17.9 19.9 23.7 Locked rotor amps 46 60.8 64 77 112 109 152.5 Condenser Fan Motor Full load amps 0.6 0.7 0.7 0.6 1 1 1 Locked rotor amps 1.1 1.2 1.3 1.5 2.3 2.3 2.3 Line Voltage Data (Volts -Phase -Hz) - - - 208/230-3-60 208/230-3-61 208/230-3-62 208/230-3-63 Maximum overcurrent protection (amps)2 - - - 20 30 30 35 Minimum circuit ampacity3 - - - 12 18 18 21 Compressor Rated load amps - - - 8 13.2 13.1 15.9 Locked rotor amps - - - 71 88 110 110 Condenser Fan Motor Full load amps - - - 0.6 1 1 1 Locked rotor amps - - - 6.5 2.3 2.3 2.3 Line Voltage Data (Volts -Phase -Hz) - - - 480-3-60 480-3-60 480-3.60 480-3-60 Maximum overcurrent protection (amps)2 - - - TBD TBD TBD TBD 3Minimum circuit ampacity_ - - - TBD _ TBD TBD _ _ TBD Compressor Rated load amps - - - TBD TBD TBD TBD Locked rotor amps - - - TBD TBD TBD TBD Condenser Fan Motor Full load amps I - - - TBD TBD TBD TBD Locked rotor amps I - - - TBD TBD TBD TBD 'Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. 8 INTEGRATED HOME COMFORT Air Electrical Data 0 I RHiT/RH2T Series ANC) W Electrical Data - With Electric Heat RH1T Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RH1T Heater Model No. Heater kW (2(480V)V) PH/H2 No. Elements kW Per Type Supply Circuit Sinle Circuit Multiple Circuit Amps. Motor Ampacity Minimum Amircuit pacity Maximum Prircuit otector RXBH-17?03J 2.2/3 1/60 1 - 3 SINGLE 10.8/12.5 2.8 18/20 20/20 RXBH-1724?05J 3.6/4.8 1/60 1 -4.8 SINGLE 17.3/20 2.8 26/29 30/30 RXBH-1724?07J 5.4/7.2 1/60 2 - 3.6 SINGLE 26/30 2.8 36/41 40/45 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40 2.8 47/54 50/60 RXBH-1724A07C 5.4/7.2 3/60 3 - 2.4 SINGLE 15/17.3 2.8 23/26 25/30 2417STAN RXBH-1724A10C 7.2/9.6 3/60 3 - 3.2 SINGLE 20/23.1 2.8 29/33 30/35 RXBH-1724A13C 9.4/12.5 3/60 3-4.17 SINGLE 26.1/30.1 2.8 37/42 40/45 RXBH-1724A13J 9.4/12.5 1/60 3-4.17 SINGLE 45.1/52.1 2.8 60/69 60170 RXBH-1724A13J 3.1/4.2 1/60 1 - 4.17 MULTIPLE CKT 1 15/17.4 2.8 23/26 25/30 RXBH-1724A13J 6.3/8.3 1/60 2 - 4.17 MULTIPLE CKT 2 30.1/34.7 0 38/44 40/45 RXBH-17?03J 2.2/3 1/60 1 - 3 SINGLE 10.8/12.5 4.1 19/21 20/25 RXBH-1724?05J 3.6/4.8 1/60 1 -4.8 SINGLE 17.3/20 4.1 27/31 30/35 RXBH-1724?07J 5.4/7.2 1/60 2-3.6 SINGLE 26/30 4.1 38/43 40/45 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40 4.1 49/56 50/60 RXBH-1724A07C 5.4/7.2 3/60 3 - 2.4 SINGLE 15/17.3 4.1 24/27 25/30 RXBH-1724A10C 7.2/9.6 3/60 3 - 3.2 SINGLE 20/23.1 4.1 31/35 35/35 RXBH-1724A13C 9.4/12.5 3/60 3-4.17 SINGLE 26.1/30.1 4.1 38/43 40/45 RXBH-1724A13J 9.4/12.5 1/60 3-4.17 SINGLE 45.1/52.1 4.1 62/71 70/80 RXBH-1724A13J 3.1/4.2 1/60 1 - 4.17 MULTIPLE CKT 1 15/17.4 4.1 24/27 25/30 3617STAN RXBH-1724A13J 6.3/8.3 1/60 2 - 4.17 MULTIPLE CKT 2 30.1/34.7 0 38/44 40/45 RXBH-1724A15C 10.8/14.4 3/60 3-4.8 SINGLE 30/34.6 4.1 43/49 45/50 RXBH-1724A15J 10.8/14.4 1/60 3-4.8 SINGLE 51.9/60 4.1 70/81 70/90 RXBH-1724A15J 3.6/4.8 1/60 1 -4.8 MULTIPLE CKT 1 17.3/20 4.1 27/31 30/35 RXBH-1724A15J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40 0 44/50 45/50 RXBH-1724A18C 12.8/17 3/60 3 - 5.67 SINGLE 35.5/41 4.1 50/57 50/60 RXBH-1724A18J 12.8/17 1/60 3-5.67 SINGLE 61.6/70.8 4.1 83/94 90/100 RXBH-1724A18J 4.3/5.7 1/60 1 - 5.67 MULTIPLE CKT 1 20.5/23.6 4.1 31/35 35/35 RXBH-1724A18J 8.5/11.3 1/60 2 - 5.67 MULTIPLE CKT 2 41.1/47.2 0 52/60 60/60 RXBH-1724?03J 2.2/3 1/60 1 -3 SINGLE 10.8/12.5 4.1 19/21 20/25 RXBH-1724?05J 3.6/4.8 1/60 1 -4.8 SINGLE 17.3/20 4.1 27/31 30/35 RXBH-1724?07J 5.4/7.2 1/60 2 - 3.6 SINGLE 26/30 4.1 38/43 40/45 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40 4.1 49/56 50/60 RXBH-1724A07C 5.417.2 3/60 3 - 2.4 SINGLE 15/17.3 4.1 24/27 25/30 RX81-1-172010C 7.2/9.6 3/60 3-3.2 SINGLE 20/23.1 4.1 31/35 35/35 3621HTAN/ 4821MTAN/ RXBH-1724A13C 9.4/12.5 3/60 3-4.17 SINGLE 26.1/30.1 4.1 38/43 40/45 4821STAN/ RXBH-1724A13J 9.4/12.5 1/60 3-4.17 SINGLE 45.1/52.1 4.1 62/71 70/80 6021STAN RXBH-1724A13J 3.1/4.2 1/60 1 -4.17 MULTIPLE CKT 1 15/17.4 4.1 24/27 25/30 RXBH-1724A13J _ 6.3/8.3 1/60 2-4.17 MULTIPLE CKT_2_ 30.1/34.7 0 38/44 40/45 RX131-1-172015C - 10.8/14.4 3/60- 3-4.8 - -SINGLE- 30/34.6 4.1 43/49 45/50 RXBH-1724A15J 10.8/14.4 1/60 3-4.8 SINGLE 51.9/60 4.1 70/81 70/90 RXBH-1724A15J 3.6/4.8 1/60 1 -4.8 MULTIPLE CKT 1 17.3/20 4.1 27/31 30/35 RXBH-172015J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40 0 44/50 1 45/50 • Supply circuit protective devices may be fuses or "HACK" type circuit breakers. • Largest motor load is included in single circuit and multiple circuit 1. • If non-standard fuse size is specified, use next size larger standard fuse size. • J Voltage (230V) single phase air handler is designed to be used with single or three phase 230 volt electric heaters. In the case of connecting 3-phase power to the air handler terminal block without the heater, bring only two leads to the terminal block cap, insulate and fully secure the third lead. [ ] Designates Metric Conversions J✓ CLEARANCES I WALL 6" (152.4) 24" ' (609.6) i Service I 18rr 24'r (457.2) (609.6) 24" recommended + 12" minimum I! WALL 24" (609.6) Service 12" (304.8) 24" (609.6) 24" recommended 12" minimum NOTE: NUMBERS IN () = mm IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate venhtlation to prevent recirculation of discharge air. 24" (609.6) Service 12" (304.8) 24" (609.6) Service D r r 6" (152.4 ST-A1225-01-00 JL6 D Air Performance Data "0 1 RA14 Series W Performance Data @ AHRI Standard Conditions - Cooling (con't.) Air Handler Ratings Outdoor Unit Air Handler Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [Us] AHRI# RBHP-17 18000 [5.3] 11900 [3.5] 6100 [1.8] 15 12.5 600 [283.2] 7493619 RHi 131817STAN 17900 [5.2] 13500 [4.0] 4400 [1.3] 14 12.2 600 [283.21 7490727 RA1418AJ1 RHIT2417STAN 18200 [5.3] 13800 [4.0] 4400 [1.3] 15.5 13 600 [283.2] 7490728 RH2T2421 MTAN 18800 [5.5] 14900 [4.4] 3900 [1.1] 16 13 700 [330.4] 7490730 RHIV2417STAN 18500 [5.4] 14200 [4.2] 4300 [1.3] 16 13 650 [306.8] 7490729 RBHP-17 24000 [7.0] 16100 [4.7] 7900 [2.3] 14.5 12.2 800 [377.61 7493626 RH1P2417STAN 24200 [7.1] 18300 [5.4] 5900 [1.7] 14 12.2 800 [377.6] 7490963 RA1424AJ1 RHIT2417STAN 24600 [7.2] 18700 [5.5] 5900 [1.7] 15.5 13 800 [377.6] 7490964 RH2T2421 MTAN 25200 [7.4] 18100 [5.3] 7100 [2.1] 16 13 700 [330.41 7490966 RH1V2417STAN 24800 [7.3] 19100 [5.6] 5700 [1.7] 15.5 13 850 [401.2] 7490965 RBHP-21 29800 [8.7] 20400 [6.0] 9400[2.8] 16 13 1000[471.9] 7493633 RH1P3017STAN 28600 [8.4] 21400 [6.3] 7200 [2.1] 14 11.5 950 [448.41 7491225 RMT3617STAN 29400 [8.6] 22400 [6.6] 7000 [2.1] 15.5 13 1000 [471.91 7491226 RA1430AJ1 RH1T3621MTAN 31600 [9.3] 24100 [7.1] 7500 [2.2] 16 13 1175 [554.5] 7491227 RH1V3617STAN 29200 [8.6] 22200 [6.5] 7000 [2.1] 15 12.5 1025 [483.7] 7491228 RH1V3621WAN 30800 [9.0] 22700 [6.7] 8100 [2.4] 16 13 1000 [471.91 7491229 RH2V3624HTAC 32400 [9.5] 24600 [7.2] 7800 [2.3] 16 13 1200 [566.3] 7491230 RBHP-21 36200 [10.6] 24500 [7.2] 11700 [3.4] 15.5 13 1200 [566.3] 7493638 131-11 P3017STAN 33800 [9.9] 23800 [7.0] 10000 [2.9] 14 11.5 950 [448.4] 7491515 RMT3617STAN 34600 [10.1] 24800 [7.3] 9800 [2.9] 15.5 13 1000 [471.91 7491516 RA1436AC1 RH1T3621MTAN 37400 [11.0] 26800 [7.9] 10600 [3.1] 16 13 1175 [554.5] 7491517 RH1V3617STAN 34800 [10.2] 25100 [7.4] 9700 [2.8] 15 12.5 1025 [483.7] 7491518 RH1V3621WAN 37600 [11.0] 27100 [7.9] 10500 [3.1] 16 13 1200 [566.3] 7491519 RH2V3624HTAC 39000 [11.4] 28300 [8.3] 10700 [3.1] 16 13 1200 [566.3] 7491520 RBHP-21 36200 [10.6] 24500 [7.2] 11700 [3.4] 15.5 13 1200 [566.3] 7493646 RHIP3017STAN 33800 [9.9] 23800 [7.0] 10000 [2.9] 14 11.5 950 [448.4] 7491806 RMT3617STAN 34600 [10.1] 24800 [7.3] 9800 [2.9] 15.5 13 1000 [471.9] 7491807 RA1436AJ1 RHIT3621WAN 37400 [11.0] 26800 [7.9] 10600 [3.1] 16 13 1175 [554.5] 7491808 RHiV3617STAN 34800 [10.2] 25100 [7.4] 9700 [2.8] 15 12.5 1025 [483.7] 7491809 RHIV3621MTAN 37600 [11.0] 27100 [7.9] 10500 [3.1] 16 13 1200 [566.3] 7491810 RH2V3624HTAC 39000 [11.4] 28300 [8.3] 10700 [3.1] 16 13 1200 [566.31 7491811 RBHP-24 42000 [12.3] 28100 [8.2] 13900 [4.1] 15 13 1400 [660.7] 7493654 RMT4821STAN 42500 [12.5] 32000 [9.4] 10500 [3.1] 15 1 12.5 1400 [660.7] 7491986 RHIT4824STAN 43000 [12.6] 33500 [9.8] 9500 [2.8] 15 12.5 1550 [731.51 7491987 RA1442AC1 RH2T4824MTAN 44000 [12.9] 31500 [9.2] 12500 [3.7] 16 13 1400 [660.7] 7491989 RH1V4821STAN 42000 [12.3] 31500 [9.2] 10500 [3.1] 15 12.5 1400 [660.7] 7491988 RH2V4824HTAC 44500 [13.0] 33300 [9.8] 11200 [3.3] 15.5 13 1600 [755.11 7491990 RBHP-24 42000 [12.3] 28100 [8.2] 13900 [4.1] 15.5 13 1400 [660.7] 7493657 RMT4821STAN 42500 [12.5] 32000 [9.4] 10500 [3.1] 15 12.5 1400 [660.7] 7492161 RA1442AJ1 RHIT4824STAN _ _ 43000 [12.6] _ _ _ 33500 _ [9.8]- 9500 [2.8]-- _ 15 12.5 -1550 [731.51 _ _ 7492162 . RH2T4824MTAN 44000 [12.9] 31500 [9.2] 12500 [3.7] 16 13 1400 [660.7] 7492164 RH1V4821STAN 42000 [12.3] 31500 [9.2] 10500 [3.1] 15 12.5 1 1400 [660.7] 7492163 RH2V4824HTAC 44500 [13.0] 33300 [9.8] 11200 [3.3] 15.5 13 1600 [755.11 7492165 RBHP-24 45500 [13.3] 29600 [8.7] 15900 [4.7] 15 12.5 1400 [660.7] 7493660 RMT4821STAN 47000 [13.8] 35600 [10.4] 11400 [3.3] 14.5 12 1575 [743.3] 7492359 RMT4824STAN 47000 [13.8] 35400 [10.4] 11600 [3.4] 15 12.5 1550 [731.51 7492360 RA1448AC1 RH2T4824MTAN 48000 [14.1] 33500 [9.8] 14500 [4.2] 15.5 13 1400 [660.7] 7492363 RH1V4821STAN 46000 [13.5] 33400 [9.8] 12600 [3.7] 14.5 12 1400 [660.7] 7492361 RH1V4824STAN 47500 [13.9] 36400 [10.7] 11100 [3.3] 14.5 12 1625 [766.91 7492362 RH2V4824HTAC 49000 [14.4] 35800 [10.5] 13200 [3.9] 15 12.5 1600 [755.1] 7492364 [ ] Designates Metric Conversions 38 5 - INTEGRATED HOME COMFORT Certificate of Product Ratings AHRI Certified Reference Number: 201435280 Date: 06-18-2019 Model Status : Active Old AHRI Reference Number: 8954591 AHRI Type: RCU-A-CB Outdoor Unit Brand Name: RHEEM Outdoor Unit Model Number (Condenser or Single Package) : RA1442BJ1 Indoor Unit Model Number (Evaporator and/or Air Handler) : RH1T4821STAN Region : Southeast and North (AL, AR, DC, DE, FL, GA, HI, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA, AK, CO, CT, ID, IL, IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI, WY, U.S. Territories) Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this RHEEM product is responsible for the rating of this system combination. r �- Rated as follows in accordance wl h t e latest edition fo ANSI/AHRI 210/240 with Addenda. and 2, Performance Rating of Unitary t 1 n , L . I — / I. . I , 11;+l Air -Conditioning & Air -Source Heat Pump Equipment and•s6b)ect tc rAting acZ`i,racy by Ri-sponsored, indepen t, t i ird`party testing: Cooling Capacity (A2)-,Single or High Stage (951), btu v 41000 SEER 15.00 f EER (A2) - Single or High Stage (95F) : 12.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown along with the Previous (Le, WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated; AM entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's Individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better'" and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which Is listed above, and the Certificate No., which Is listed at bottom right. ©2019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132053605790881018