Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-19-537
Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 GQ'a�n�3s t Issue Hate: 03/20/2019 Location Address Parcel Number 9632 NE 5TH AVENUE RD, Miami Shores, FL 33138 1132060170140 Contacts Permit NO.: R-03-19-537 Permit Type: ROOF Work Classification: Tile Permit Status: Approved Expiration: 09/ 16/2019 DAVID ELIAS HALABU Owner ALPERO GENERAL CONTRACTOR Contractor 9632 NE 5 AVE, MIAMI SHORES, FL 33138 ALFREDO PEREZ Other: 3052137625 6830 SW 104 ST, PINE CREST, FL 33156 Business: 7863577414 LETIMANRI@YAHOO.COM Description: NEW TILE ROOF Valuation: $ 6,000.00 Inspection Requests: 3F 5-?`kA949 Total Sq Feet: 1,000.00 Fees Amount Application Fee - Other $50.00 CCF $3.60 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $1.20 Roofing Fee $200.00 Scanning Fee $12.00 Technology Fee $6.25 Total: $279.30 Payments Date Paid Amt Paid Total Fees $279.30 Cash 03/20/2019 $229.30 Credit Card 03/12/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating con truction anzoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized SjjrWtuAf.- Owner / Applicant / Contractor / Agent March 20, Date Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED M R 12 ,2019 BY• F C20 /'�' BUILDING Master Permit No. C, 3-- /I ~JZ�o PERMIT APPLICATION Sub Permit No7v:i�`63--101' S3z? ❑BUILDING ❑ ELECTRIC 6;0 ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL PUBLIC WORKS [—]CHANGE OF [:]CANCELLATION [:]SHOP g l CONTRACTOR DRAWINGS JOB ADDRESS: ` ��o�-• �I G • SCI.��u'L'Q'� 1Oa'o City: Miami Shores r County: Miami Dade Zip: NIC38 Folio/Parcel#:l/ _201 %(' d / :?-' 0/ yd Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simplle1Titleholde /r r Address: ?634 , 46 ' City: xhao? State: Tenant/sLess_ee Name: Email Phone#: Phone#: p: 3 313'y -- CONTRACTOR: Company Name: 'gl)gso 64a"Os l Phone#: Address: S- L()• /,Q) *4,-V _ City: ii'1 • _State: 0-1 Zip: Qualifier Name: •b Phone#: �+N'P' C�& 00 106 State Certification or Registration #: �� a'� 1 a Certificate of Competency #: DESIGNER: Architect/Engineer: one#: Address: // City: State: Zip: Value of Work for this Permit: $ Y) b 0 0 Square/Linear Footage of Work: Type of Work: T4 Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: ivy TL Ve tod P _ Specify color of color thru the: Submittal Fee $ Scanning Fee $ Technology Fee $_ Structural Reviews $ (Revised02/24/2014) Permit Fee $ Radon Fee $ Training/Education Fee $ CCF $_ DBPR $ CO/CC $ Notary Double Fee $ Bond $L55 TOTAL FEE NOW DUE $ 2Z fQ• 3 0 . Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zi Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspectio which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not'7a roved and a reinspection fee will be charged. Signature OWNER or AGENT Signatu The foregoing inf trument was acknowledged before me this The foregoing instrume6 was acknowledged before me this 3 day of M41& -1 120 �I by jy�r ndaay� of , by PAAO� Qfju ��spe n to I�CiYY� C.�who is personal) nown to ,nuHrrr me or who has produced .�` ,aIC r ,.t'� me or who has produced identification and who did take an oath. GOMMISS F`� ''�identification and who did take an oath. i NOTARY PUBLI GC '.��c Z NOTARY PUBLIC: v Gp2S3S5 -5 - G ES `o • p " c�,' m f3 � • c� 2� a AU07S 2020 Sign: " � o�a�:' Sign: qf�. ea r '���.Stateo'%�\ Print: 'r1 Public,7�a.��`. Print: ,'' Seal: Seal: APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Department of Regulatory and Economic Resources Board Administration Section M1AMi`QADE 11805 SW 26"' Street (Coral Way) • Room 230 Miami, Florida 33175-2474 Telephone 786-315-2573 Fax 786-315-2570 www.miamidade.gov/development MEMO TO: All u' di g fic� Mi i Dade County FROM: ecretary of th Board Board of Rules and Appeals DATE: April 26, 2018 SUBJECT: Disciplinary Action Alfredo Perez Rojas, Qualifying Agent Alpero General Contractor Inc State License #CGC1510221 8900 SW 12611 Terrace Miami, FL 33176-5154 As a result of a Formal Hearing before the Board of Rules and Appeals on April 191h, 2018, the above Contractor's permit privileges have been ADMINISTRATIVELY SUSPENDED in Miami -Dade County. This memorandum is to request that your Department REFRAIN FROM ISSUING ANY NEW PERMITS UNDER THIS LICENSE. This suspension does not apply to actions taken to close out existing permits. If you have any questions concerning this matter, please do not hesitate to contact Jorge Pena, Contractor Enforcement Supervisor at 786-315-2511. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Bafrdrng Cade 5th Edition (2014) PFCEIVEI:) i High -Velocity Hurricane Zone Uniform Permit Application Form. MAP 12 2019 1 Section A (General Information) Master Permit No. _ Process Contractor's Name it( //�� Job Address !A9 C;L !� / • ROOF CATEGORY 0 Low Slope 0 Mechanically Fastened Tile 0 Asphaltic Shingles ❑ Metal Panel/Shingles CZ Prescriptive BUR-RAS 160 ROOF TYPE • . ••.••• , ortarlAdllegive Set -Aes © Wood ghirl IeaShake • • New roof 0 Repair ❑ Maintenance ' ' Reroofing • • O• Reco rin • • I • • • .. Ye A. I . ROOF SYSTEM INFORMATION • • Low Slope Roof Area (SF),,... Steep sloped Roof AREA (SSF) Total (SF) Section B (Roof Plan) r C) `' 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- I lions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. adelll' 7` 7'd e-,, i MEMO �Irir E"®�.�.. ��I®��i�►��1��1�® NMI ■ 01 IN Ml Ilium FLORIDA BUILDING CODE — BUILDING, Sth EDITION (21014) 15.57 11,11.11 PETER' 1 1 Copyright to, or licensed by, ICC {ALL RIGHTS RESERVED} acomed by Eliezer Paiacio .201 G 32:1 A pursLicense Agrxment. No further reproductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Sth Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form t SectionD (Steep Sloped Roof System) ! Roof System Manufacturer: a ✓a 0 rI Gam► n C c C Notice of Acceptance Number. d Minimum Design Wind Pressures, if Ap Ilcabie (From RAS 127 r Calculations): `'p 004,00 � Deck Type: ^/ Type Underlayment: �.t4 1 • • P • • • • • R Slope: �_ 12 Insulation: �� ...... Fire Harrier: • • • • it Ridge Veit' 'on? G r� Fat e yp & ing: S ;bo 1� -5 -pp/ 1 •c• A �ive�fype: SP 1 �� A I Type Cap Sheet: Ll 1 t Mean Roof Height: � Roof Covering:' Type & Size Drip 1 Edge: FLORIDA BUILDING, CODE — BUILDING,:Sth EDITION (1614) 15.39 t ! y I F Copyright to, or licensed by, [CC (AU. RIGHTS RBSF,R VED); accessed by Eliezer Paiacio on Jun $, 2015 10:32:12 AM pursuant to License i Agreement. No further reproductions authorized. ROOFAS6EMBLIES AND ROOFTOP STRUCTURES Florida Building: Code 5th .Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (TileCalculations) For Moment based the systems choose either Method 1 or 2. Compare the values for Mr with the values from A. if the M, values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable. Q. M thod 1 "Mg1pent Based Tile, ale trrod Per RAS 127" (P x xOnKII. -A-'Mg: -M, ' �S((JJuct Approval M, (P2i % x1 = j 9 = M uct Approval M, 1 •• • (P3 !±xk4AA Q7.1�) --mg: = M� uctApproval Mf �• • • Method 2 "Simplified 'rite Calculations Per Table Below" ."". Required Moment Resistance (M,) From Table Below Prodiint Annrnval nn 41494,41 Mr required Moment Resistance' • Mean' Roof Height 15' Roof Slope 20' 25' 30' • • • • 2: f2 34.4 36.5' 38.2 39.7 . 42 2 312 322 34.4 36.0 37.4 •. 9a8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6: 32.8 34.9 6:12 26.4 2&0 29.4 30.5 32A 7:12 24.4 25.9 27.1 28.2 30.t) .. .. ...... • •• •....• • •• . v . . 'Must be used in conjunction with a list of moment based the systems, endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F" with the values for Fr, If the F' values are greater than or equal to the Fr values, for each area of the roof, then the the attachment method is acceptable. Method 3 'Uplift Based Tile Calculations Per RAS 12r x w: ) - W: —,x cos 0 y = Fr, ____,_ Product Approval F' s (P2:__-- x L - _ x w: = _) - W: _ x cos 0 _ = Fa _ Product Approval F' (P3`., x L = xw: = ) - W x +cos 0 . = F� . Product Approval F` Where to Obtain Information' Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier I Product Approval Restoring Moment due to Cravdy M. Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Ma Cat fated Minimum Attachment Resistance F Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 FLORIDA BUILDING CODE -- BUILDING, 5th EDITION 2014 1 l�t, ■ 1 ® C*PYriBbt to, or licensed by, iCC (ALL RIGHTS RESERVED); accessed by EJieur Palacio on Jun 6, 2015 10:32:12 AM pursuant to License. Aft. No further reproductions authurized. `SNoaes y� F�ORtOP SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of S (MeR4402 govern the minimum requirements and standards of the industry for roofing system insCallaiOns. AddilonAly, the00 �•��� following items should be addressed as part of the agreement between the owner ant the cQniaractor.•Tj�•�v�ner's •„•; • ... . initial in the designated space indicates that the item has been explained. •„:„ , 2. 4Renailing wood decks: When replacing roofing, the existing woogroo4deck :my heye to ••�••� be renailed in accordance with the current provisions of Section R4403. (The rMf deck is ustally ••••;• concealed prior to removing the existing roof system). • • • • • • •. . . . . ...... 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the9rppf :ecking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. & M Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessaryinstall overflow scuppers in accordance with the requirements of Sections R4402, R44p�' t�J' 1$. Co CX Property Address Permit Number Revised on 7/9/2009 LD;07/01/2015; /s Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 , / Re: Owner's Name: �CG!/�f�lq lots Dater Property Address: $ �,GCQ (�De?G+' Roofing Permit Number: • • • • • Dear Building Official: • • • • .. • • • I)kLAi d hL i -acertify that I am not required to retrofit the roof to well cormecti®ns of rra)4 . building because: • • :....: 4—bejust valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 'ion of the South Florida Building Code (1994 SFBC) LOPF?'''%,, Sig ture Print Name ` l� Numbesc,O'L GG025355 �^ State of Florida EXPIRES a County of Dade 0 .01 U'2��hru qat° �I,ZN .: The undersigned, being the first duly sworn, deposes and says that he/she ' the owner for the above•prgp`e�pfy�M� '16$ied, QD Sworn to and subscribed before me this day of Notary Public, Sate of Florida at When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $30 000.00 nd the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 MIAMI-DADE COUNTY MIAMI•DDE PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoloc4.modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to fe�voke th4aeceptanee,.000 if it is determined by Miami -Dade County Product Control Section that this product or'r$atetial failt to Peet the • • requirements of the applicable building code. ' • • • • • This product is approved as described herein, and has been designed to comply with; *e•Florida Building Cddt' • •; including the High Velocity Hurricane Zone of the Florida Building Code. 9090 ..... .. .. . .. ...... DESCRIPTION: Plantation Roof Tile • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, oit , stat�'�t[d followjn*g • statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein! • • • . • . . RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0721.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Applicant Plantation Tile Trim Pieces Length: 16'/z" Width: 13" L = varies W = varies Varying thickness 2.1. MANUFACTURING LOCATION 1. Okeechobee, FL Test Product • • Specifications .... ...... .Desdription_ • TAS 112 Flat concrete ?cWttfle for dltect;eck ar • •: • battened nail-Qn mortar or adhesive sC' - ...• 0 application • • • • • • ' s'.... • ••••• TAS 112 ...... Accessory trim; concrete�obf pteces 00 • use at hips, !Mdges andvalley •' terminations'. Martufacti.jr for eachtylso% profile. .'. • . . 00 2.2 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BONDTM Roof Tile Adhesive DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam, Inc. NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date American Test Lab of South RT0624.05-14 TAS 112 07/03/14 Florida Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & PA 102(A) The Center for Applied 94-060B Static Uplift Testing March, 1994 Engineering, Inc. 94-084 PA 101 (Adhesive Set) May 1994 (Mortar Set) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II PA 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 PA 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied Project No. 307025 Wind Driven Ram ••UR,1994 Engineering, Inc. Test #MDC-76 PA 100 '..' : Aerodynamic Multipiief.. .... ...... • • ' �Qd4 1992 Walker Engineering, Inc. Calculations . . .:: • • • • • • • April 1999. . Walker Engineering, Inc. Calculations 25-7183 ."••. :.1gpch 199;5""'• 25-7094 ' •" 'February 1996 •. 25-7496 ••�•�� .'Ali'ril1996•••• Walker Engineering, Inc. Calculations 25-7584 ire Member 1996 •:. 25-7804b-8 : • 25-7804-4 & i :""• �.� 25-7848-6 • • .. "• • • • Walker Engineering, Inc. Calculations Two Patty Adhesive Set System �•�April 1999 Farabaugh Engineering and T295-11 TAS-108 10/05/11 Testing Inc. Farabaugh Engineering and T306-11 TAS-108 10/04/11 Testing Inc. Farabaugh Engineering and T279-11 TAS-108 09/23/11 Testing Inc. PRI Construction Material DAPF-004-02-08 TAS 101 07/26/18 Technologies DAPF-004-02-09 Static Uplift Resistance 07/26/18 DAPF-004-02-10 Adhesive Set 07/26/18 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 3 of 7 3.4,' Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) "Go*** Tile Profile Weight-W (Ibf) Length-1 (ft) •••• ; Width-w �ft) Plantation Tile 11.6 1.375 0--0900 •••;•• 1. •• Table 2: Aerodynamic Multipliers - 1 (ft3) ""'• .... Tile X (ft3) (ft3): Profile Batten Application . •'..x Direct -Deck Application Plantation Tile 0.267 3Y891•.•: • Table 3: Restoring Moments due to Gravity - M (ft.-Ibf) • • Tile Greater than Profile 21,:12" 3":12" 411:12" 591:12" 6":12" 7":12" Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck Deck Deck Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Tile NOA No.: 18-0829.02 MIAMI•DAD, CO F,192571111 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (Min 16/32" (Min. 19/32" plywood) plywood) Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2 Nails 1-10d Smooth or 7.3 9.8 4.9 Screw Shank Nail 2-10d Smooth or 14.0 18.8 7.4 Screw Shank Nails 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or 24.3 24.3 24.2 Screw Shank Nail Field Clip) 0000 1-10d Smooth or 19.0 19.0 '27.1 ••• Screw Shank Nail . . Eave Clip)• ... . . .. .. ... 2-10d Smooth or Screw Shank Nails 35.5 35.5 ... •••• 34..8 ;••• ' :""' .... Field Clip) • • • • • •• • ..:. 2-10d Smooth or 31.9 31.9 .. • 32. ... • Screw Shank Nails :":': • Eave Clip) • . . . ...... .... • . . 2-10d Ring Shank 50.3 65.5 : A83 ' Nails' • 1 Installation with a 4" the headiap and fasteners are located a minimum of 2'/z"from the head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive 2 See manufactures component approval for installation requirements. 3 The Dow Chemical Co. TILE BONDTm Roof Tile Adhesive weight per patty 13.9 grams. 31.3 4 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two -Component weight per patty 8 grams. 31.3 5 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 8 grams. 45 8711 PIMKO APPROVED NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 5 of 7 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) For Single Patty Adhesive Set S stems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesives 6 See manufactures component approval for installation requirements. 7 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160 Two -Component weight per patty 45 grams. 118.9 8 ICP Adhesive and Sealants, Inc. ICP Adhesve Pol set®AH-160 Two -Component weight per patty 24 grams 40.4 9 DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 45 grams. 73 10 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 24 grams 48 Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance See specific mortar manufacturer's Notice of Acceptance. 5. LABELING . . .... ...... All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logoas•setn belovvos%ollowing.:. statement: "Miami -Dade County Product Control Approved". ....•.• • .... . ..... ...... .. . ..... .. .. . .. ...... . . . . ...... OR .. .. 7.�7ENTEMRR,,,,� BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 18-0829.02 Mtarti DnDe couN7�r Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 6 of 7 M IAMI V MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/economy Polyglass USA Inc. I I I I W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the hi<Lepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediatA+ evoke, mo3ify* or j suspend the use of such product or material within their jurisdiction. RER reserves the right�tp�rpyQke this•,Loee Ptance, if it is determined by Miami -Dade County Product Control Section that this product or materi&LUJs to meet the • • • requirements of the applicable building code. 0000 0 • •''; This product is approved as described herein, and has been designed to comply with the FloridaOtzildingXoae' 00600 0 including the High Velocity Hurricane Zone of the Florida Building Code. so:**: • • • 1 : • • .. .. . .. ...... DESCRIPTION: Polyglass Polystick Underlayments :":'; •� . . . . ...... LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,` tr, sjate ar.*d following • • • • statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. '.;..• RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page I of 8 ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick IR-Xe 65' x 3'33/$" ASTM D 1970 A fine granular/sand top surface self -adhering, APP Manufacturing Or 65' x 3' polymer modified, fiberglass reinforced, bituminous Location #1 & #2 60 mils thick sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. Polystick Dual Pro 6 F x 3'3-1/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a Location #2 metal roofing and roof tile underlayment. Polystick Tile Pro y 61' x 3'33/s" �.... 0 � � . 60 TAS 103 and A rubberized asphalt self-adh�' 0090 p leg, glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing mern4raag.Desig'1W0,j4a metal,,.;, Location #2 roofing and roof tile underlayx►eo►;.•. Polystick TU Max 65'8" x 3'3-3/8" ...... TAS 103 and A rubberized asphalt self-adh(?rjng,.l?olyesitteitrforcedo....� Manufacturing. 60 mils thick ASTM D 1970 waterproofing membrane. DesiWi"as a a rpoftile ..;,. • Location # 1 & #2, underlayment. 000000 . •. .. •. •. Polystick TU P 32' 10" x 3'33/8" TAS 103 and A rubberized asphalt waterproofing piemb�ne, Mass- : Manufacturing 130 mils thick 0, . . ASTM D 1970 fiber/polyester reinforced, with a granular Sdmee , , Location #2 designed for use as a tile roof imderlyment. •. :""; Polystick TU Plus 65' x 3'33/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester (Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location # 1 & #2 Polystick MTS 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick MTS Plus 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastoflex S6 G 32'10" x 3'3-%" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Resort Date Trinity ERD P 10870.09.08-R I TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-2 ASTM D 1623 08/07/12 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103, TAS 110 & ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 & TAS 110 10/07/14 P43290.10.14 ASTM D 1970 & TAS 110 10/17/14 PLYG-SC10130.06.16-3 TAS 103 & TAS 110 ••6912.7/16 PLYG-10130.06.16-1 ASTM D1970 & TASIJQ•�: ,06727/16 PRI Asphalt Technologies PUSA-035-02-01 TAS 103 "':" �'091�;/06 PUSA-055-02-02 TAS 103 • • • • 12/10/07 PUSA-089-02-01 TAS 103/ASTM D4798 & C1115 ; • 9406/09 Momentum Technologies, Inc. JX20H7A TAS 103/ASTM D4798 &G>,SS .�0401/08 RX14E8A TAS 103/ASTM D4798 &G1,55 14/09/09 DX23D8B TAS 103/ASTM D4798,; G155 :.QJf18/10 DX23D8A TAS 103/ASTM D4798 $ GL5S 02/18/10 LABELING: *000% . . ****:o 6600% 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: • • • • Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a oninim m 4" Iead4ap. (for • • • • • base sheet only) • • Membrane: 00 Elastoflex S6 G, hot asphalt applied Surfacing: •; • • See General Limitations Below. .... • .... . ..... ...... .. . ..... Deck Type 1: Wood, non -insulated • • • • "' • • • Deck Description: Min. 19/32" plywood or wood plank .. ••: • System Type E(3): Base sheet mechanically fastened to deck, subsequent cap mejnbMe self: adhered. :....: • Anchor/Base Sheet: • • • . • • • • ' One or more plies of ASTM D 226 Type II or ASTM D 2626. 0*00 Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. ." GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. ...... .. .. ...... 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polyrtick'MTS plus may be• • : • • • used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, rood tWt-jstem , and tWarry • • • • • slate roof assemblies. • • • • • " Polystick TU P may be used in all the previous assemblies listed except metal roofing; • • ; •; ' • Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof the sym;rns. 0 • • 0 0...... Polystick TU Max may be used in non-structural metal roofing and roof tile systems. • 0 0 Elastoflex S6 G may be used in roof tile systems only.00*0 ' 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Ex osure Limitations (Days) MTS IR-Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A N/A N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 Rule 61 G20-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (U) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus MTS Plus with Dual Pro TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens Profiled Prohibited 4:12 6:12 6:12 4:12 6:12 Tile without battens • • • • • • 10. The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System '. Notice of Acceptance and applicable Florida Building Code requirements. When batt21V*tOrequire8,,* * shalt • • • • be utilized during loading and installation of tiles. • • • • • • •••• . . • • Care should be taken during the loading procedure to keep foot traffic to a minimum and 4e avoid dropping of • •; • • • tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loadinMceduCe- t*p tiles• • • • • laid perpendicular to slope followed by a maximum four the stack parallel to the slope'fotV total of 6 tilts — for• • • •: • all underlayments except Polystick MTS which shall be loaded onto battens. : • • : • : • • .000 POL16 nCKTU Plus NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is " ijgptable, • • • • • Please also refer to applicable Product Data Sheets of the corresponding products. • • • • , 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edgy tCM as per"Polnlass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimurh*f 8"'metal disk as :**so: required in Miami -Dade County or simplex type nail as otherwise allowable in other rejoionsp44witat a m rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail ar%jalga para.glavar" on ..... the face of membrane, with the above stated nails and/or disks. The head lap membrang.it19'cover ihd,14 being..... back -nailed. (Please refer to applicable local building codes prior to installation.) • . • 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. :...:. 0 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polrglass. : • • Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cements XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the the manufacturers NOA, must be used on all projects for pitch/slopes of TV12" or greater. It is suggested that on pitch/slopes in excess of 6'/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 10. Ail self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE •••• . . •••• •••••• . .. • ...... .. •• ....% •••••• • .*Go** •••• . • .*0000 ...... .. . ..... .... . .. ...... 00 . . . . •••••• 00*0 NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8 of 8 MIAMI-DADE COUNTY MtAMMM PRODUCT CONTROL SECTION MMEMP 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy ICP Adhesives and Sealants, Inc. 12505 NW 40 Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet theiggUirements of the applicable building code. . . • • 000000 . . This product is approved as described herein, and has been designed to comply with t1te Florida including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset' AH-160 $LiiWi4g Code • • .. .. ...... ...... .. . ..... LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, cty, state and Tollowi$g statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein: • • ; • • • • • • • • • • • . RENEWAL of this NOA shall be considered after a renewal application has been filed A. Veer: has heerl go chan:e • • •; in the applicable building code negatively affecting the performance of this product. ' •.•• TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives Polyset®AH-160 ICP Adhesives Foam Dispenser RTF1000 ICP Adhesives ProPack® 30 & 100 N/A TAS 101 Two component polyurethane foam adhesive N/A Dispensing Equipment N/A Dispensing Equipment' ' ...... 000090 PRODUCTS M O .... ...... . . . .. .. ...... . . ....• ANUFACTURED BY THERS. • •.... .. ..:..' Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current 46;which list atiaclunent" resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. •0 ...... MANUFACTURING LOCATION: 0 0 • . • 1. Tomball, TX. 0000 PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @158'F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test AQency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier Test Name/Report Date #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 NB-589-631 ASTM D 1623 02/01/94 9637-92 ASTM E 108 04/30/93 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[i] ASTM E 84 01/16/95 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 044W42 P39740.02.12 TAS 101 02G 42 ...... TAS 123 • • • .' ...... .. .. ...... 528454-2-1 TAS 101 • • • • • • 10/23/98 • 528454-9-1 •••• • 528454-10-1 "" • • • • • 520109-1 TAS 101 •:••: 1028AS 520109-2 .. .. . .. ...... 520109-3 • 520109-6 . . . . •••••• ...... 520109-7 •••••• 520191-1 TAS 101 06-uoz 9 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. ."". . . .... ...... 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. ' 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minuses ailer ICP Adhesives 000 Polyset® AH-160 has been dispensed. 00 .0 0 0 .0 .... 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accarclance wit; WO 0 • • • •.. 'Placement Details' herein. Each generic tile profile requires the specific placement nbVh( rein. ; • • • • • • • • .. .. . .. ...... . . . . ...... NOA No.: 17-0322.03 M�4r�i•oaDe CouNrr Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles # 1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of the 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams vader pan LABELING: • All approved products listed herein shall be labeled and shall bear the imprint or identifiable rm4cigg of tt e • •: • • • manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" ar the Miami****-. Dade County Product Control Seal as shown below. • • • • • • • • • • • • • •••• •• B UILDING PERMIT REQUIREMENTS: • • • • As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 NAt%roughplank carnant PaddyMmoatl%T") itail»a n t•quleaxlp 4hnlrrArymrne ° • ta6Casss optional ° EaveCourse ° a 1 Fain. Ery Cl•iur•—°- Hall ffirough pbstk cement lwhen reoulred) airtaIn. : sin.wid• Battens optional Pu44iO11•nooth T'ls rl i txra cimaura Fascia OW4hceugtt101* 41G PrsldjItiOrnw4h731r1 ( whearacitaltedl 1 vhdrer+yns4a,e ° 10in.x 21n. w4" eaRtans apMonal pF EFascia t01n. Ih. 6rae doswv 4'fripadga Flat/Low Profile Tile l . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cmz) — 23 (148.4 cmz) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a miqimum 2" (50.8 mm) x 10" (254 rsim) Y. 1" (25%gyy7 foam. • •. • paddy onto the underlayaht } ositiorled aseshown under the pan portion okke 4i4e closeslrto►tlre *a**:* overlock of the tile being aetr • 0 0 • •••• • • • •.•••• 2. Continue in same manner.' frfsure approximately i7; • •. (109.7 cmz) — 23 (148.4 anj Zquare:inch adhesive contact with the undersl. . e o the tile.. ....... ...... . • • . 000000 •••••. •• • • •• • • •••• High Profile / Single Pan Tile l . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cmz) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 Weil thrawah pultic cement #when regai►edl Bebtem optional ADHESIVE PLACEMENT DETAIL # 2 Fasdo Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12(77.4 cm2) square inch adhesive contact with the underside of the tile. . • • • • . e .... ...... . .. .. ...... Medium Profile / Double Pa e. 0�e. e 0000 ...... 1. Starting at the eave course'gppVa miniftt;2" (50e8. mm) x 10" (254 mm) x 15,4§Av1m) fQwn paddy ..;. • onto the underlayment positihod as shown.iinder thee e e e s pan portion of the tile closlotcrtfie overlook of the e tile being set. Insure apprMimatt ly 17 ��Q9�.�0cm2) -0 • 09 0 • 23 (148.4 cm2) square incl adbftve contact with thQ e...: underside of the tile. • • • ; .110. • eee 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm') square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nall through pLni k oa {haheerequired) pW&YlNa laTll'0 dlr.fayr»aet �04N- 2 Im h;atermoptional + gave cow" a. axis vh phou Eff" clom• Drip edge High Profile / Single Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the the closest to the overlock pf "le being set. •*a• • ••.... . • • 3. Continue in same manner. Inru*.Wproximately 17" ...... (109.7 cm2) - 19 (122.6 cm2 square inch•adhes ive ....: contact with the underside of 4wathe. ' • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 1.1 ADHESIVE PLACEMENT DETAIL # 3 Nail though plastic cernent Paddy(between tpes7 When requlredl Battens optional ° + Paddy {under cite) Single paddy entopoftde x a In." Sunder h ` single paddy,�i-' 'tea on underlaym `r' 2 x t in. 0 loin. 2 in Fascia EaMe clome Flat/Low Profile Tile Nap through plastic cement Single paddyundertde (when required] Pa ddy ibetween tiles) Battens optional Pad (under tile) S- d P f tn� xain. �ngj le addy an 5 yment x s ln. loin. zln. Eave aosure Eave Course Fasda Medlunt PtofllaTile On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x V (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile the closest to the Overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mmj -Ko V (25.4 mm) foam paddy onto tho undrilayment jaAt elow...... the second course line positioned foaru padd: ..... . under the strengthening rj>Z 4 � Dat tile,'oY Liter the ... • . pan portion of the tile, clojq.4p the underlock for:... the second course tile tote.iwfalled. InaxI6 0 • approximately 8-9 in2 (5�1.F►4SO cm2; Pf adhesive ". contact with the underside oftfie tile.: 0 0 0 " • • • • • 000000 (Instructions continued on next Age) . NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nall through plastic 51 a paddy under the (when requfredj Paddy ibetrreen tiles) Battens optional Paddy lunderWei Shuiile Gnu "4x 4 in. Single 7x4iny°x.+' e, paddy an We tap of Eave Course" Fascia Weephole loin. 2 in. Eare closure Drip edge High ProtileTtle 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 1/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. •••• • • • • •••• 000000 • • • 06 • • • • •••• •••••• • • • ••• ••• •• • • • •••••• •••••• •• • • •• •••••• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 1) Place enough adhesive to achieve 6S to 70 1 In contact with the pan tile. 2) Turn coven upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq.In. contact area; Underlayment Eave closure (molar shown) Fascia ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Steep pitch applications (when required) Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure save end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with theeuladerside of the pan tile. : ... ••••• •••••• ..e 3. Turn covers upside doyvri *xposing UICunderside), a*.:. of the tile. Apply a min"Vie 1" (25.4 ttim) x 1Of.... (254 mm) bead of adh%s v;•directl}aeiadq inner• • edge of each side of t"rwipr tile. Leave • •; • • • approximately 3/4" (1004"Ito 1" j23.4 i�im) • • • • • from the outside edgevfitile, inward, free of •. foam to allow for exptinsiorx e 4. Turn cover tile over afTc?r foaam is jg4ed and e • e a*: fim place onto pan tile course. Insure a"itum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11