Loading...
RF-10-20-2462Miami shores Village Building department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # T v > 2� 6 INSPECTION AFFIDAVIT DATE: 1 I ' 2 ti • 10 i S V i k q C-/ jc C," licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) License #: Cc C I � 0 vl y On or about Lt - 10' °' Ati I r (Date & time) work at (` IJISC�-j k�' 1 a (Complete Job Site Address) FS 468 Building Inspector I did personally inspect the roof deck naiiin Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned, Sworn to and subscribed before me this i`���' �''�CY _day of a'� ���� �r.•.•, SIGALAUERGEL Notary Public - Slate of Florida Commission # GG 141133 � ' My Conran Exi''v%% Sop 4, 2021 Notary Public, Sate of Florida at Large ""' Unn::eda 'General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit Of and address # clearly shown marked on the deck for each Inspection 0-1—1 ran i7111111 9A1Fr941onno FLORIDA INTERNATIONAL ENGINEERING INC. 6175 NW 167th Street, Suite G-20, Miami, Florida 33015 .I.E. Telephone: (305) 378-1991 - Fax: (305) 378-1997 FLORIDA INTERNATIONAL ENGINEERING Miami -Dade Lab Certification # 07-0612.11- State of Florida CA # 27273 SITE SPECIFIC INFORMATION Job Address: 10115 Biscayne Blvd, Miami Shores, FL 33138 Contractor: Victory E&I Roofing And Construction LLC Permit # RF-10-20-2462 Test Date: 3/11/2021 Type of Tile: Eagle Dark Charcoal Approx Height 20 Floor: 2 Type of Access: Scaffolds: - Ladder. YES Slope: 4/12 App. Sq.Ft: 37 squares Req. Force: 45 1bs Testing Equipment: F.G.E. 500H X. Shimpo Instrument Dear Sir/Madam: As per your request and authorization, representatives of Florida International Engineering Inc performed the static load test on the rooting the at the above referenced project. The purpose of this testing was to verify whether the installed tile roofing system is capable of resisting the applied test load of 35 pounds uplift force. This testing was performed in general accordance with Miami Dade Building Code Protocol PA 106. The static load was applied utilizing a calibrated scale and force measuring instrument (dynamometer). A hook which is connected to the loading instrument was placed under the exposed edge of the tile. Test load of 45 pounds force (Ibt) was applied and also held for more than 5 second at each test location. The total load applied on each test location was recorded. In addition to the static load test, the tested tile was also visually inspected for any kind of adhesion failure after completion of each test. No. Result No. Result No. Result No. Result No. Result 1 Pass 21 Pass 41 Pass 61 Pass 81 2 Pass 22 Pass 42 Pass 62 Pass 82 3 Pass 23 Pass 43 Pass 63 Pass 83 4 Pass 24 Pass 44 Pass 64 Pass 84 Pass 25 Pass 45 Pass 65 Pass 85 6 Pass 26 Pass 46 Pass 66 Pass 86 7 Pass 27 Pass 47 Pass 67 Pass 87 8 Pass 28 Pass 48 Pass 68 Pass 88 9 Pass 29 Pass 49 Pass 69 Pass 89 10 Pass 30 Pass 50 Pass 70 Pass 90 11 Pass 31 Pass 51 Pass 71 Pass 91 12 Pass 32 Pass 52 Pass 72 Pass 92 13 Pass 33 Pass 53 Pass 73 Pass 93 14 Pass 34 Pass 54 Pass 74 Pass 94 15 Pass 35 Pass 55 Pass 75 Pass 95 16 Pass 36 Pass 56 Pass 76 Pass 96 17 Pass 37 Pass 57 Pass 77 Pass 97 is Pass 38 Pass 58 Pass 78 Pass 98 19 Pass 39 Pass 59 Pass 79 99 20 Pass 40 Pass 60 Pass 80 100 Based on our findings, we conclude that the installed roofing rile at t�goboksuil fjbjenced project is capable to resist the applied test BALA �4 load. Therefore we conclude that it meets the Miami Dade Buil�ctt ` A+ m l&Zl %yrotocoI TA 106. Attached is the roorp[an showing approximate test locations. Na 63107 •'.9`� r Respectfully Submitted, OO ** :c t GSa+r. �:,• STATE OF •: J 3,24.2021 VinayngState of ar M. B l c #ishna v, P.E. ON % �+r'`��►/A� tiE�, aIU• FLORIDA INTERNATIONAL ENGINEERING INC. FLORIDA INTERNATIONAL 6175 NW 167th Street„ Suite G-20, Miami, Florida 33015 ENGINEERING Telephone: (305) 378-1991 -Fax: (305) 378-1997 Roof Testing rr►►rl I►►fannatio►► Sheet 46 .I$ 5l' 5G id �I 3G OK IG 1� Id 12 d2 37 � xz (D x7 o 2a 21 f9 18 Il 2G 58 B 59 a3 3S 28 35 34 33 32 13' E as 72 4a 39 23 �O 50 G2 i5 8 77 a7 as 71 �3 Gi Ga 73 78 G3 GS G7 L Ga GG 7i 8 S A 57