Loading...
RF-01-21-40 AFFMiami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 W: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # V= u� INSPECTION AFFIDAVIT DATE: 11 U�3 I I Love I S Tb) u licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) FS 468 Building Inspector License #: tr h C. = 1515 C0 (C� 1-1K On or about ��� 1'a� a I , I did personally inspect the roof deck nailing (Date & time) work at ID9140-L (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this — libVILAWY day of 16-11 Notary Public, Sate of Florida at Large MAYELIS PEREZ MY COMMISSION # HH 069221 EXPIRES: February 4, 2025 Bonded Thru liotargPr�LNc Underwriters "General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the Fool mn permit # and address # clearly shown marked on the deck for each inspection aa„-1— 17tn1')n1n1Gn1ionno DocuSign Envelope ID: BF1D7C31-B993-4CO3-A972-4CA26B9F4425 FLORIDA TEC PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH FBC PROTOCOL TAS-106 Lab Report No. 132406 C.A. # 30448 Lab Certificate # 18-1114.01 PROPERTY ADDRESS: 10940 NW 2na Ave., Miami PERMITNo: RF-01-21-40 PROPERTY OWNER: Terrance B Washington ROOFING SQUARES: 17 CONTRACTOR: T&S Roofing Systems. Inc. ROOF PITCH: 4:12 TILE TYPE: Spanish "S" INSPECTOR INITIALS: AA ATTACHMENTMETHOD: Foam Adhesive TESTDATE: 04/05/2021 Testinq Equipment: Uplift Gauge FGE-100X Test Tabulation Required Testing Force: 35 Ibs No. RESULT No. RESULT No. RESULT No. RESULT No. RESULT I-9 Passed 10-19 Passed 20-27 Passed THIS ROOF HAS PASSED THE STATIC UPLIFT IN ACCORDANCE WITH FBC PROTOCOL TAS-106. "ROOF SKETCH" 38' Sincerely, Yan L. Solis, P.E. Lic. No. 75423 OamSigned by: Yam. " Sala 93B2 nNW2C411... 4/5/2021 53' 2 3 7 5 L- - - - - - 1 4 6 ?6 24 i The method and software that have been utilized to sign and seal the report, comply with the intent of the Board Rules. Specifically, with reference to Florida Statutes 471 and the Florida Administrative Code Rule 61 G15-23.003 for Engineers. �����►�riirll�r�� .�� L • S o C E•N *'• No. 75423 '* �•,. STATE OF �.... �RL O R I d �� 10735 SW 216" St. Unit 404 Tel: 305-256-4550 Miami FL 33170 Page 1 of 1 www.FloridaTEC.net Fax: 305-256-6833 DocuSign Envelope ID: BF1D7C31-B993-4CO3-A972-4CA26B9F4425 Lab Report No. FLORIDA TE0 5 PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY C.A. # 30448 Lab Certificate # 18-1114.01 CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH FBC PROTOCOL TAS-106 PROPERTY ADDRESS. 10940 NW 2nd Ave.. Miami PERMITNo: RF-01-21-40 PROPERTY OWNER: Terrance B Washington ROOFING SOUARES: 17 CONTRACTOR: T&S Roofing Systems. Inc. ROOF PITCH- 4:12 TILE TYPE: Spanish "S" INSPECTOR INITIALS. AA ATTACHMENT METHOD: Foam Adhesive _ TEST DATE: 04/05/2021 Testina Eauioment: Uplift Gauge FGE-100X Test Tabulation Required Testing Force: 35 Ibs No. RES ULT No. RESULT No. RESULT No. RESULT No. RESULT 1-9 Passed 10-19 Passed 20-27 Passed THIS ROOF HAS PASSED THE STATIC UPLIFT IN ACCORDANCE WITH FBC PROTOCOL TAS-106. "ROOF SKETCH" Sincerely, Yan L. Solis, P.E. Lic. No. 75423 EA OaaoBipn� bY: t."SA4 93829769992C4II.. 4/5/2021 2 3 F -- -- - J _. 1 4 6 24 38' 5 53' 7 The method and software that have been utilized to sign and seal the report, comply with the intent of the Board Rules. Specifically, with reference to Florida Statutes 471 and the Florida Administrative Code Rule 61 GI5-23.003 for Engineers. 8 J J 9 N 10 � C'E'jlj Nn. T5a23 STATE ❑F .�;• F�OR1D 10735 SW 2161h St. Unit 404 Tel: 305-256-4550 Miami FL 33170 Page 1 of 1 www.FloridaTEC.net Fax: 305-256-6833