Loading...
RF-07-20-1446 ULTi _Z�\_ Engineered Construction Solutions Inc. Attention: City of Miami Shores Village Building Department Re: After the Fact Inspection For Property located at 150 NW 99th Street, Miami Shores, F133150 Roofing Contractor: Kairos Roofing Permit # RF-07-20-1446 Certification of Authorization # 32643 284 SW I Ill Street Pompano Beach F133060 September 8, 2020 Dear Building Official: This letter is to advise the Building Department that we have performed a limited exploratory after the fact inspection and reviewed the photos provided by Kairos Roofing of the roof installed at the above -mentioned project location. We reviewed the roofing work; the tile was installed with ICP adhesive with a minimum 2"0" foam paddy per the NOA detail. The starting course has a 2"x10" foam paddy per the NOA detail. Please note we consider this letter an "in progress inspection" after the fact to cover for the in - progress inspection normally performed by the City. To the best of my knowledge, belief, and professional judgement the work was done in accordance with the approved plans and Florida Building Code 2017. This inspection does not cover roof drainage and does not provide a guarantee against roof leaks or any other contractual obligations the contractor is solely responsible for including but not limited to worksmanship. ������I►r l � � ur�r���� 846548 Sincerely, Erik Nemaf-i, P.F. STATE OF PE #84648F� � �4p�� ssrar,�k . ��` Certificate of Authorization # 32643 284 SW 11th Street Pompano Beach, FI 33060 Encincered Constniction solutions Inc Florida Building Code 2017 Test Application 106- Standard Procedure For Field Verification of the Bonding of Mortar or Adhesive Set Tile Systems and Mechanically Attached, Rigid, Discontinuous Roof Systems Attention: Miami Shores Village Buuilding Department 10050 NE 2nd Avenue, Miami Shores, FL 33138 Client: Kairos Roofing Proiect Information Property Address: 150 NW 99th Street, Miami Shores, FL 33150 Permit #: RF-07-20-1446 Roof Pitch: 3/12 Type of Tile: Boral Roof Tile Roof Area: 22.95 SQ. Tile Attachment Two Component Polyurethane Foam Adhesive -Poly Pro AH 160 Method: Field Instrument: IMADA DST- 110A Serial Number: 403780 Test Location Perimeter Area: 14.00 SQ. Field Area: 18.00 SQ. Number of Corners: 8.00 SQ. Ridge Pieces: 132 PCS. Total Number of Tests 14 18 8 14 Field Uplift Pull Test Test Result As per FBC 2017 Pass As per FBC 2017 Pass As per FBC 2017 Pass As per FBC 2017 Pass Field Notes: No broken or loose tiles found during time of test. These field tests can change due to the future weather impacts and/or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test performed. Please see attached Roof Sketch for this project ''���tttt t t s r i t r rrr►r�: F' .,rr'l��Vemati, P.E. - 4• : W. 94648 ` No. 84648 .p'. STATE OF .,,� aNAL1, rr+Ifliliiill��� cn rn ............. 00 IIlS1SS�j1'•