Loading...
CC-19-333Location Address Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 11300 NE 2ND AVE SAGE, Miami Shores, FL 33161 Contacts lir Issue Date: Parcel Number 1121360000050 Permit NO.: CC -02-19-333 Permit Type: BOUng (C,timmerciat) Wank Classification: Alteration Permit Status: Approved Expiration: 09/03/2019 BARRY UNIVERSITY INC Owner PP3 CONSTRUCTION CORP Contractor BARRY UNIVERSITY GABRIEL RODRIGUEZ 11300 NE 2 AVE, MIAMI SHORES, FL 331616628 750 96, MIAMI SHORES, FL 33138 Business: 3053890065 Other: 3057575129 Description: REPAIR EXISTING STAIR AND 2ND FLOOR Valuation: $ 28,000.00 Inspection Requests: RAILINGS 305-762-4949 Total Sq Feet: 0.00 Fees Application Fee - Other CCF DBPR Fee DCA Fee Education Surcharge Permit Fee Planning and Zoning Review Fee Scanning Fee Structural Review ($45) Technology Fee Total Amount 200.00 16.80 12.60 8.40 5.60 640.00 35.00 9.00 45.00 21.00 993.40 Payments Date Paid Amt Paid Total Fees 993.40 Credit Card 02/13/2019 $200.00 Credit Card 03/07/2019 $793.40 Amount Due: 0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify thatal'tt1foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. FL r e, I authorize the above named contractor to do the work stated. Authorized Signature: Owner March 07, 2019 Contractor / Agent Date Page 2 of 2 BUILDING PERMIT APPLICATION Miami Shores Village P'P'cE1V 8n Building Department FEB 13 2019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 BY% INSPECTION LINE PHONE NUMBER: (30S) 762-4949 FBC 2011 G Master Permit No. Sub Permit No. OBUILDING ELECTRIC ROOFING REVISION EXTENSION RENEWAL F-] PLUMBING MECHANICAL F-1 PUBLIC WORKS CHANGE OF CANCELLATION SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 11300 NE 2nd Avenue (Sage Hall) City: Miami Shores County: Miami Dade Zip: 33161 Folio/Parcel#: Is the Building Historically Designated: Yes NO X Occupancy Type: B Load: Construction Type: 111 B Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Barry University, Inc. Phone#: 305-899-3790 Address: 11300 NE 2nd Avenue Cit,. Miami Shores State: Florida Zip: 33161 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: PP3 Construction, Corp. Phone#: 305-389-0065 Address: 750 NE 96th Street City: Miami Shores State: Florida Zip: 33138 Qualifier Name: Gabriel Rodriguez Phone#: 305-389-0065 State Certification or Registration #: CGC1516509 Certificate of Competency #: DESIGNER: Architect/Engineer: Cesar Castillo, PE Phone#: 954-803-8968 Address: 10500 Waves Way city: Parkland State: FL Zip: 33076 Value of Work for this Permit: $ 28,000.00 Square/Linear Footage of Work: Type of Work: Addition Alteration New ON Repair/Replace Demolition Description of Work: Repair existing Stair and 2nd Floor Railings Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ Revised02/24/2014) Bonding Company's Name (if applicable) NA Bonding Company's Address City State Mortgage Lender's Name (if applicable) NA Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fge will be charged. Signature \I Irl'.tL;R. 7lCUL-7 I 1!7iX a rte OWNER or AGENT CO<TRAC4 Z The foregoing instrument was acknowledged before me this 2` day of FGgPLAAAW .20 12 by S 17,OSb I Q( who is p rconally known to Tegr who has produced identification and who did take an oath. NOTARY Sign Expkes November 12, 2022 90NTWTroyF1brMiri =8 The foregoing instrument was acknowledged before me this day of 20 5 by a'(-- 9 Z-14ho is personally known to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Print: ' JEFF J.YAO Seal: =+IcCommI aM I GG 249916 Expires Nevember 12, 2022 1.6;;;f,`A 8onM7ftTrgFdnMmi ance=*5.7019 APPROVED BY W V Plans Examiner 7/ 1`{ Structural Review Revised02/24/2014) as Zoning Clerk Cesar Castillo, PE Florida Reg. # 68447 10500 Waves Way, Parkland, FL 33076 Ph: 954-803-8968 - cesarcastillopabon@gmail.com Cover Sheet Structural Calculations Project: Aluminum Railings Repair .:...: Barry University 11600 NE 2nd Avenue' Miami, FL 33161 0 Customer: Barry University Designer: Cesar Castillo, PE Florida Reg. # 68447 ____----- FBC 2017 ASCE 7-10 ADM - 2015 GGR 1 A 1 Cesar Castillo, PE Florida Reg. # 68447 10500 Waves Way, Parkland, FL 33076 Ph: 954.803-8968 - cesarcastillopabon@gmail.com Design Criteria & Applicable Codes: Codes: FBC 2017 ASCE 7-10 ADM - 2015 ALUMINUM RAILINGS HORIZONTAL RAIL Material: Aluminum 6061-T6 Fy= 35.00 ksi Fb= 21.00 ksi Fv= 14.00 ksi Profile: Dixie Cap 2-5/8"x1-1/2" A= 0.573 int Sx= 0.178 in Sy= 0.317 in W= 0.05 kips/ft W= 0.0042 kipslin P= 0.200 kips L= 48 in Horizontal checking: M,= WxL2/8= 1.200 kips -in M2= PxU4= 2.400 kips -in M= 2.400 kips -in Srqr= 2.400 = 0.114 in 21.00 Sy= 0.114 in < 0.317 in 0.114 0.361 < 1 0.317 Vertical checking: M,= WxL2/8= 1.200 kips -in M2= PxU4= 2.400 kips -in M= 2.400 kips -in Srqr= 2.400 = 0.114 in 21.00 Sx= 0.114 in < 0.178 in 0.114 0.642 < 1 0.178 Use: Dixie Cap 2-5/8"x1-1/2" Aluminum 6061-T6 o.k. o.k. o.k. o.k. FEB 10 2019 Cesar Castillo, PE Florida Reg. # 68447 10500 Waves Way, Parkland, FL 33076 Ph. 954-803-8968 - cesarcastillopabon@gmail.com 2 CHECKING VERTICAL PICKET Material: Aluminum 6061-T6 Fy= 35.00 ksi Fb= 21.00 ksi Fv= 14.00 ksi Profile: SQ 0.75" x 0.093" A= 0.244 int Sx= 0.048 in' Sy= 0.048 in' W= 0.050 kips/sf W= 0.0017 kips/in L= 33 in Horizontal checking: M,=WxL/8= M= 0.231 kips -in Srqr= 0.231 = 0.011 in' 21.00 Sy= 0.011 in' < 0.048 in' o.k.'.;•' 0.011 = 0.231 1 o.k. 0.048 Use: SQ 0.75" x 0.093" Aluminum 6061-T6 3 TYPICAL POST AT 20" AFF Material: Aluminum 6061-T6 (welded) Fy= 35.00 ksi Fb= 9.00 ksi Fv= 5.50 ksi Profile: SQ 2.00" x 0.125" A= 0.900 int Sx= 0.530 in' Sy= 0.530 in' P= 0.200 kips L= 21 in M= 4.20 kips -in fb= 7.92 ksi 7.925 = 0.9 1 o.k. 9.00 Use: SQ 2.00" x 0.125" Aluminum 6061-T6 (welded) FEB 10 2019 4 5 Cesar Castillo, PE Florida Reg. # 68447 10500 Waves Way, Parkland, FL 33076 Ph: 954-803-8968 - cesarcastillopabon@gmail.com TYPICAL POST AT FFE Material: Aluminum 6061-T6 (welded) Fy= 35.00 ksi Fb= 9.00 ksi Fv= 5.50 ksi Profile: SQ 2.00" x 0.25" A= 1.750 int Sx= 0.910 in' Sy= 0.910 in' P= 0.200 kips L= 42 in M= 8.40 kips -in fb= 9.23 ksi 0000.. 9.231 = 1.0 =< 1 o. k. 9.00 0000. 0000 000*0 Use: SQ 2.00" x 0.25" Aluminum 6061-T6 (welded):": CHECKING CONCRETE EMBEDMENT FOR POSTS L= C,= P= fc= a= a= P2= P2= P,= do= Vu= Vu= Vu 5458 0000.. 42.00 in ' 4.00 in ' 0000 4.00 in 200 lbs 6000 psi (epoxy grout) m/3)*(2m+3 L)/(m+2L) 2.03 in a2* P)/(m * (2 * a - m)) 3401 lbs P2 -P= 3201 lbs 0.75 3.50 in 7*(a/do)^(0.2)(do*fe)^(0.5)*(C,)^(1.5) 5458 lbs 1.6P2 5121 lbs Drill 0 3" x 4" depth. Fill with non -shrink grout. o.k. Q aZ_ FEB 10 2019 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0000.. 0000.. Cesar Castillo, PE Florida Reg. # 68447 10500 Waves Way, Parkland, FL 33076 Ph: 954.803-8968 - cesarcastillopabon@gmail.com 6 CHECKING PLATE CONNECTION TO CONCRETE P= 0.20 kips d= 44.50 in M= 8.90 kips -in d= 4.00 in n= 4 T= 1.113 kips Per each anchor V= 0.050 kips Per each anchor Try: Wedge bolt anchor 0 3/8" (min emb 3.50") Min. emb.= 3.50 in Ru -t= 2.535 kips Tension at full capacity 0000' Ru -v= 1.590 kips 000 Shear at full capacity • • • 000.0. d,= 4.0 in Space between bolts 080090 d2= 4.5 in Minimum distance for full cqd tit9 0000.. d,/d2= 89% Of full capacity e,= 2.5 in Edge distance from bolts •':": e2= 4.5 in Minimum edge distance forlull capacity 0' e,/e2= 56% 0000.. Of full capacity - Critical • 0000.. T= 1.113 kips < 1.408 kips ' •.' o.k.. 0 V= 0.050 kips < 0.883 kips o.k.'.;..' Checking stress: 1.113 + 0.050 = 0.847 < 1 o.k. 1.408 0.883 Use: Wedge bolt anchor 0 3/8" (min emb 3.50") 7 CHECKING HANDRAIL BRACKET CONNECTION AT CONCRETE WALL P= 0.200 kips d= 3.00 in M= 0.600 kips -in n= 1 ea d= 2 in T= 0.300 kips Per each anchor V= 0.200 kips Per each anchor FEB 10 2019 0000.. 000.0 0000. 00.00 0000. 0000.. 0000.. 0000. Cesar Castillo, PE Florida Reg. # 68447 10500 Waves Way, Parkland, FL 33076 Ph: 954-803-8968 - cesarcastillopabon@gmail.com Try: Hilti Kwik Bolt 3, CS 0 1/4" (min emb 2.00") Min. emb.= 2.00 in Ru -t= 0.623 kips Tension at full capacity Ru -v= 0.458 kips Shear at full capacity d,= 48.0 in Space between bolts d2= 6.0 in Minimum distance for full capacity d,/d2= 100% Of full capacity e,= 4.0 in Edge distance from bolts e2= 3.5 in Minimum edge distance for full capacity e,/e2= 100% Of full capacity - Critical T= V= Checking stress: 0.300 + 0.623 0.300 kips < 0.623 kips o.k. •....- 0.050 kips < 0.458 kips • • • o.k. • • 0.050 = 0.591 0.458 Use: Hilti Kwik Bolt 3, CS 0 1/4" (min emb 2.00") FEB 10 2019 Courtesy of Lavteam.org Free For ALL Dimensions Depth 1.49 in Width 2.604 in Perimeter 8.198 in Gea etnc Are 0.5725 int Ix 0.1183 in4 ty 0:4092 in4 hry 0.0021 in4 rx 0.4546 in ry 0.8454 in Sx+ 0.178 1n3 Sx- 0.1434 in3 Sy+ 0.3121 in3 Sy- 0.3165 in3 Xc 33.43 in Yc 18.81 in Principal 11 0.4092 in4 12 0.1183 in4 a 89.58 deg r1 0.8454 in Q 0.4546 in S1+ 0:3181 in3 S1- 0.3126 in3 S2+ 0.1779 in3 S2- 0.142 in3 1r Ip 0.5275 in4 rp 0.9599 in v Plastic Zx 0.2367 in3 Zy 0.4326 in3 PNA X 33.44 in PNA Y 18.69 in 0 r Z6 in Dikie Cap 3 7/22/2017 Unsaved Project FEA Mesh Torsion Minimum Results ?gults Nodes 1082 ro 0.9771 in Warping -0.5926 int 0.6136 int Elements 915 H 0:9649 Largest 0.0229 int Xsc 33.42 in Element Ysc 18;99 in Cw 0.0197 ins Part Materials J 0,2445 in4 All ASTM A36 Bt -0.0476 in ShapeBuilder 8.00.0005 www.iesweh.comMSE v 0 40 iii • 0000• 00.0.0 1.31 in 000.0 0.000• FEA Mesh Torsion Minimum Results ?gults Nodes 1082 ro 0.9771 in Warping -0.5926 int 0.6136 int Elements 915 H 0:9649 Largest 0.0229 int Xsc 33.42 in Element Ysc 18;99 in Cw 0.0197 ins Part Materials J 0,2445 in4 All ASTM A36 Bt -0.0476 in ShapeBuilder 8.00.0005 www.iesweh.comMSE ar Castillo 1 in 1.00 in 1 in 1.00 in 2 in SQ Alum 2.0" x 0.25" 2 in 0000 Y.• 0000•• 0000•• 0000 0000.. 0000.. 0000,• 0,000 00 •. 000.0 40.0• 0000 0.••• 6090. 0 Principal Properties . ... „ 11 0.91 MAA Theta 1.82 in^4 rp,... T...... 1.02 in i j- IES ShapeBuilder 4.0 www.iesweb.com 10/04/14 10:26 PM Table 2-19W ALLOWABLE STRESSES FOR BUILDING -TYPE STRUCTURES (WELDEM Allowable Sdesses FID (k" Seaton FIQ 6061-T6,T6510,TS611 AQ Products (See note) Axial Fy =15 Vint E =10,100 k/irt: axial tension stress on net D2b 12.3 FA,-15ldW k-1 . effective area dosed shapes lateral -torsional F3.1 2LbS,1(Cb(IAII2) . F„ = 24 krint axial tension stress on gross area D.2a 9.1 buckling. Flexum rectangular bars lateral-torsionat F42 (d1Q(Lb1(Cad))IM Tension Compression elements in uniform stress FSAII 9.1 we 8.5.4.1 thru B.5.4.5 and E.4.2 NOW elements in flexure F.8.12, F 4. i 11.8 11.8 see also F4.2 Wetded with 5183, 5356, or SM. round tubes F6.1 10.5 10.6 see also F62 or Wailed with 4043,5554, or.5W4 rods F.7 11.8 11.8 and a 375" thick one edge in columns bolts or rivets on holes J.3.7a, J.4.7 24.6 bolts on slots, pins on holes, J.3.7b, J.7 16.4 an axis of symmetry fiat surfaces flat elements supported on 6:5.4.1 b/t Slerufwness - R40 for FM for F/12 for all shapers member budding E3 kL/r 8.7-0,0433 136 51,352 / Flexural ComMmIgo open shapes lateral -torsional F2.1 L./(rr.Cb" 102-0.043S . 160• 86,996/S2 • • budding dosed shapes lateral -torsional F3.1 2LbS,1(Cb(IAII2) . 102 - 0.082 SM 23,51 ./$. ; . • buckling. rectangular bars lateral-torsionat F42 (d1Q(Lb1(Cad))IM 16.0-0230S a X49 11,42011S • budding round tubes focal budding F6.2 19dt 17.7 - 0.933 S112 121 11.8 - 0.39W,2 V4. 3,776 4S(4+S'n/35)g Elements --Uniform Compression flat elements supported on B.5.4.1 b/t 9.1 9.0 12.0 - 0.327 S 25. a • 2,417=/ • one edge in columns whose buckling axis is not an axis of symmetry flat elements supported on 6:5.4.1 b/t 9.1 9.0 12:0 - 0.327 S 18.4 M/$ are edge in all other columns and all beams flat elements supported on B.5.4.2 b/t 9.1 28.2 12.0 - 0.105 S 58 346/S both edges flat elements supported on B.5.4.4 40 9.1 21.8 102 - 0A51 S 133 60,414 /S= both edges and with an Intermediate sliffener curved elements supported 6.5.4.5 i3,/t SLI 4&4. 11.8 -0.396 S'R 390 3,776QS(I SwMA at both edges flat elements--attemate 8.5.4.6 9.1 45.1 12.0 - 0.065 S 92 654/S method. Elemmnis-Flexural Com flat elements supported on 8.5.5.1 b/t 11.8 642 16.0-0.065.5 123 982/S both edges flat elements supported on 13.5.52 b!t 11.8 11.9 16.0 - 0.350 S 30 4,932 /S2 tension edge, oompresslon edge free flat elements supported ar 8.55.3 b/t 1L8 143.8 MO - 0.M S 275 2.201" /S both edges and with a longitudinal stiffener Nat elements --alternate 8.5.5.4 11.8 41.7 16.0 - 0.0100 S 80 638/S method Elements -Shear flat elements, supported on G.2 b/t 5.5 47.5 73 - 0.038 S 126 38,665 /Sp both edges VI -52 January 2010 ALLOY 5356 WELD DATA SHEET TYPICAL APPLICATIONS Welding Filler Wire GENERAL INFORMATION Trade Designation: Almigweld and Altigweld • Non -Heat treatable Similar to AIMg5 (DIN) ...:.. EN ISO designation AIMg5Cr(A) •••• Principle alloying elements: Magnesium, Manganese, Chromium, Titanium"' Moderate high strength capabilities ..'..' Applicable specification: ANSI/AWS A5.10 (ER & R) •••••• WELDING APPROVALS •• • American Bureau of Shipping Canadian Welding Bureau Lloyd's Register Bureau Veritas RINA Korean Register Det Norske Veritas TuV CE DB TYPICAL PROPERTIES Melting range: 1060 - 1175°F Resistance to corrosion: A (Gen) C (SCC) Conductivity: 29% IACS (-O) Anodize Color: White Density: .096 lbs/cu. in CHEMISTRY OTHERS SILICON IRON COPPER MANGANESE MAGNESIUM CHROMIUM ZINC TITANIUM BERYLLIUM EACH TOTAL ALUMINUM 0.25 0.40 0.10 0.05-0.20 4.5-5.5 0.05-0.20 0.10 0.06 -0.20 0.0003 0.05 0.15 REM NOTE: SINGLE VALUES ARE MAXIMUM UNLESS OTHERWISE NOTED. AlcoTec Wire Corporation 2750 Aero Park Dr., Traverse City, MI 49686-9263 U.S.A. 1-800-228-0750 FAX: 231-941-9154 E-mail: sales alcotec.com Website: www.alcotec.com TYPICAL MECHANICAL PROPERTIES OF GMAW GROOVE JOINT WELDS 1. Metal thickness of %" or greater for fillet welds sometimes employs a double vee bevel of 50 deg or greater included vee with 3/32 to 1/8 inch land thickness on the abutting member. 2. Electrode consumption given for weld on one side only and based on leg length equal to plate thickness. 3. For 5XXX series electrodes use a welding current in the high side of the range given and an arc voltage in the lower portion of the range. 1 XXX, 2XXX, and 4XXX series electrodes would use the lower currents and higher arc voltages. WELDING APPLICATIONS A CHARACTERISTIC OF THE 5XXX SERIES OF ALLOYS IS THEIR SUSCEPTIBILITY TO STRESS CORROSION CRACKING WHEN THE WELD POOL CHEMISTRY IS GREATER THAN 3% Mg AND THERE IS EXPOSURE TO PROLONGED TEMPERATURES IN EXCESS OF 1500 F. SPECIAL ALLOYS AND TEMPERS ARE OFTEN REQUIRED TO OVERCOME THIS PROBLEM. CONTACT ALCOTEC FOR ASSISTANCE IN ALLOY AND TEMPER SELECTION WHEN ELEVATED TEMPERATURE SERVICE IS A CONCERN. AlcoTec Wire Corporation 2750 Aero Park Dr., Traverse City, MI 49686-9263 U.S.A. 1-800-228-0750 FAX 231-941-9154 E-mail: salesCd alcotec.com Website: www.alcotec.com BASE ALLOY PROPERTIES AS WELDED BASE ALLOY UTS(KSI) UYS(KSI) ELONGM UTS(KSI) UYS(KSI) ELONGM 6061-T6, -T651 45 40 12 30 19 11 6063-T6 35 31 12 20 12 12 7005 -T6, -T63 54 46 12 46 30 10 7039-T64 65 55 13 44 25 13 5086-H32 42 30 12 39 17 17 Typical Semiautomatic GMA Procedures for Fillet and Lap Welding Aluminyrn DC(EP)3 Base' DC(EP) Wire Arooh : Approximate Wire Dia Range Thickness Suggested Feed Gas.liIow Coas8woplion2 Inches Ams Volts Inches Amps Volts IPM QFA•• Lbs/19OFt 100-130 18-22 094 100 22 500 30 • • 0.76030 125-150 20-24 125 120 22 600 3{ • • 1 035 85-120 20-23 094 110 22 480 30 • • • V 7S• 125-150 20-24 125 130 22 566 1 ' 170-190 21-26 250 170 23 740 35 047 125-150 20-24 125 150 23 360 3d • 1. • •. 180-210 22026 187 180 23 410 30 2 3• 170-240 24-28 250 190 24 470 40 4 062 190-260 21-26 250 200 23 265 50 4 240-300 22-27 375 230 24 300 50 9 260-310 22-27 500 260 26 340 60 16 280-320 24-28 750 280 27 385 65 36 290-340 26-30 1.000 300 28 420 70 64 094 280-360 26-30 750 320 29 170 60 36 300-400 26-32 1.000 330 30 180 80 64 1. Metal thickness of %" or greater for fillet welds sometimes employs a double vee bevel of 50 deg or greater included vee with 3/32 to 1/8 inch land thickness on the abutting member. 2. Electrode consumption given for weld on one side only and based on leg length equal to plate thickness. 3. For 5XXX series electrodes use a welding current in the high side of the range given and an arc voltage in the lower portion of the range. 1 XXX, 2XXX, and 4XXX series electrodes would use the lower currents and higher arc voltages. WELDING APPLICATIONS A CHARACTERISTIC OF THE 5XXX SERIES OF ALLOYS IS THEIR SUSCEPTIBILITY TO STRESS CORROSION CRACKING WHEN THE WELD POOL CHEMISTRY IS GREATER THAN 3% Mg AND THERE IS EXPOSURE TO PROLONGED TEMPERATURES IN EXCESS OF 1500 F. SPECIAL ALLOYS AND TEMPERS ARE OFTEN REQUIRED TO OVERCOME THIS PROBLEM. CONTACT ALCOTEC FOR ASSISTANCE IN ALLOY AND TEMPER SELECTION WHEN ELEVATED TEMPERATURE SERVICE IS A CONCERN. AlcoTec Wire Corporation 2750 Aero Park Dr., Traverse City, MI 49686-9263 U.S.A. 1-800-228-0750 FAX 231-941-9154 E-mail: salesCd alcotec.com Website: www.alcotec.com NON -SHRINK PRECISION GROUT PRQOAICTW1US." PRODUCT DESCRIPTION QUIKRETE® Non -Shrink Precision Grout is a high strength, non-metallic, Portland cement based material with expansive additives designed for grouting all types of machinery, steel columns, bearing plates, pre -cast concrete, and anchoring aDDlications. PRODUCT USE Typical applications for QUIKRETE® Non -Shrink Precision Grout include grouting of: All types of machinery Steel columns Bearing plates Precast concrete Other anchoring conditions that require high in-service strength The non -shrink characteristics of Non -Shrink Precision Grout make it stable and capable of handling high load transfers. SIZES QUIKRETE`' Non -Shrink Precision Grout — 50 LB (22.7 kg) bags YIELD Each 50 Ib (22.7 kg) bag of QUIKRETE® Non -Shrink Precision Grout will yield 0.45 cu ft (12.7 Q at flowablo consistency. TECHNICAL DATA APPLICABLE STANDARDS ASTM International ASTM C109IC109M Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 24n. or [50 -mm] Cube Specimens) ASTM C827 Standard Test Method for Change in Height at Early Ages of Cylindrical Specimens of Cementitious Mixtures ASTM C939 Standard Test Method for Flow of Grout for Preplaced- Aggregate Concrete (Flow Cone Method) ASTM C1090 Standard Test Method for Measuring Changes in Height of Cylindrical Specimens from Hydraulic -Cement Grout ASTM C1107 Standard Specification for Packaged Dry, Hydraulic - Cement Grout (Nonshrink) ASTM C1107 Standard Test Method for Flow of Hydraulic Cement Mortar ASTM E488 Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements U.S. Army Corps of Engineers (USAGE) - CRD 621 Non -Shrink Grouting 03 62 00 00000 0 0 000000 0000 0000.. 0000.. 0000.. 0000. PHYSICALICHEMICAL PROPERM • : • • • • • • • QUIKRETE* Non -Shrink Precislori WuEcomplies •with I prope4ies •: • of ASTM C1107 and CRD 621 producing•fe results shown in Table 1. :000:0 TABLE 1 TYPICAL PHYSICAL PRZkRbES At 7 °f; (23•C) • • Compressive strength, ASTM C109 modified per ASTM C1107 Plastic consistency 1 day 3000 psi (20.7 MPa) 3 days 9500 psi (65.5 MPa) 7 days 10,000 psi (68.9 MPa) 28 days 14,000 psi (96.5 MPa) Height change, ASTM C1090 1, 3, 7 and 28 days 0-0.2% Height change, ASTM C827 0.6% Flowable consistency 1 day 3000 psi (20.7 MPa) 3 days 9000 psi (62.1 MPa) 7 days 9500 psi (65.5 MPa) 28 days 12,500 psi (86.2 MPa) Height change, ASTM C1090 1, 3, 7 and 28 days 0-0.2% Height change, ASTM CM 0.4% Fluid consistency 1 day 2500 psi (17.2 MPa) 3 days 5000 psi (34.5 MPa) 7 days 6000 psi (41.4 MPa) 28 days 8000 psi (55.2 MPa) Height change, ASTM C1090 1, 3, 7 and 28 days 0-0.2% Height change, ASTM C827 0.3% Pull-out strength, ASTM E4881 35,000 Ibf 111/4' (31 mm) bops embedded 9" (225 mm) deep in 3' (75 mm) hole in 2004 psi 13.8 MPa) cmaebe. INSTALLATION SURFACE PREPARATION Surfaces to receive the grout must be dean and free of any type of foreign matter, grease, paint, oil, dust or efflorescence. In some cases it, may be necessary to roughen smooth surfaces or etch old ones with acid. The area should be flushed and soaked with dean water prior to grouting leaving no standing water. Place the grout quickly and continuously using light rodding to eliminate air bubbles. MIXING Add the minimum amount of water necessary to produce the desired flow characteristics as indicated in Table 2. Do not add more water than the amount needed to produce a 20 -second flow per ASTM Test Method C 939. QUIKRETE® Non -Shrink Precision Grout should be mechanically mixed for a minimum of 5 minutes. TART F 2 APPROXIMATE WATER REQUIRED FOR 50 LB (22.7 KG) OF GROUT Plastic 1 gal 3.8 L Flowable 1 gal + 1 pt 4.3 L Fluid 1 gal + 3 pt 5.2 L WORKING TIME When properly mixed to a fluid consistency QUIKRETE® Non -Shrink Precision Grout will comply with all portions of ASTM C1107 and CRD 621 and retain a fluid consistency for the maximum usable working times stated in Table 3. TAR! F q WORKING TIME Temperature Working time 50°F (10°C) 25 min 73°F (23°C) 25 min 90'F 32'C 15 min CURING A damp cure of at least 3 days is necessary to control the non -shrink characteristics and maintain strength levels. • PRECAUTIONS' Additions of cement or other matenpp.will eliminate the designed • product qualities 0000 •• ; • • • • Water quantities may be affected•ey perature±nixiVmetho¢.... and batch size ' QUIKRETE' Non -Shrink Precisigp Orggt'shouldVtbe6Ca-temPM,,, Grout temperature should be maim Mflom 50 - 900egrees F (10 , • 32 degrees C) to achieve specifidf results. Use Wi d water in hot weather or hot water in cold weather to aghieve d*W gfbut , temperature. ' ..' .. : • • • • Do not pour grout d temperature is expected to gtAW32 degrees F (0 degrees C) within a 12 hour period. Mix no more than can be used in 30 minutes WARRANTY The QUIKRETE® Companies warrant this product to be of merchantable quality when used or applied in accordance with the instructions herein. The product is not warranted as suitable for any purpose or use other than the general purpose for which it is intended. Liability under this warranty is limited to the replacement of its product (as purchased) found to be defective, or at the shipping companies' option, to refund the purchase price. In the event of a claim under this warranty, notice must be given to The QUIKRETE® Companies in writing. This limited warranty is issued and accepted in lieu of all other express warranties and expressly excludes liability for consequential damages. The QUIKRETP Companies One Securities Centre 3490 Piedmont Rd., NE, Suite 1300, Atlanta, GA 30305 404) 634-9100 • Fax: (404) 842-1425 Referto www.quilaete.com for the mast current technical data, SDS, andguide specdkaftois Revised 28 August 2015 DESCRIPTION: HILTI Kwik Bolt 3 is a stud type expansion anchor with a single piece wedge which expands in concrete and CMU when torque is applied. they are supplied with a nut and washer. MATERIAL CHARACTERISTICS: 1" carbon steel studs, conform to AISi 11141. Nuts are carbon steel conforming to ASTM A563 Grade A and meet dimensional requirements of ANSI B18.2.2. Washers are made from carbon steel conforming to ASTM F844 and meet dimensional requirements of ANSI 18.22.1 Type A plain. All 3/8", 1/2", 5/8", and 3/4" wedges are made from carbon steel. All 1/4" and 1" wedges are made from stainless steel. GENERAL NOTES: 1) Design values in pounds are equal to ultimate load divided by 4. 2) Edge distance shall be 1.75 times the minimum embedment for tension and 3 times the minimum embedment for shear. Anchor center to center distance shall be 3 times the minimum embedment. 3) Anchor installation shall be made in accordance with Hilti's published installation instructions in the Product Technical Guide. Limit one anchor per cell. 4) Anchor installation in grouted concrete masonry units require a minimum 12" distance and 8" spacing. Limit one anchor per cell. Avoid installation within 1-3/8" of any vertical mortar joint. See Figure 1. 5) Values shown are for shear plane through the anchor body. 6) When the shear plane is acting through the anchor threads, reduce the shear by 10%. 7) When the shear plane is acting through the anchor threads, reduce the shear by 6% 8) When the shear plane is acting through the anchor threads, reduce the shear by 20%. DESIGN VALUES: Anchor Diameter (in.) Fracture Load (lb) 1/4 2,900 3/8 7,200 1/2 1 12,400 5/8 19,600 3/4 28,700 Dia- in.) Min. Embed. in.) 3000 Tension psi Shear CMU Grouted Tension Shear 1/4 2 623 458 3 8 2-1/2 1355 1460 8 780 1155 1/2 3-1/2 2185 2343 7 905 1723 5/8 4 2870 48858 1295 1723 13/4 4-3/4 1 I — Anchor Installation is Allowed in all Non -Shaded Areas 00 M I 00 Mortar Joint • • • • • • • • • • 1-3/8 Concrete Masonry Unit l —i>g" • • • • • (Groyted) FI6.1• • • • • • • w ENGINEERING 21 THURSTON IM. PALM RFACH GAFU*I&FL )]Ile OFR 1!6162501, a Fuc: (10)6254613 uW tl FLORM RSG. F 26119 / 0 ri V HILTI, INC. 5400 S 122nd E Ave Tulsa, OK 74146 HILTI KWIK BOLT 3 MECHANICAL EXPANSION ANCHOR FOR CONCRETE AND MANSONRY ELEMENTS REVISION DATE: 31-10-06 DATE: 11-12-98 DRAWING: 543-003—C SCALE: 1" = 1" SHEET NO. 1 OF 1 FOR OFFICE USE PRODUCT DESCRIPTION: THE WEDGE -BOLT ANCHOR IS A UNIVERSAL MOH STRENGTH CARBON STEEL ANCHOR DESIGNED FOR USE N STOLE AGGREGATE CONCRETE IT IS A VERSATILE, HIGH PERFORMANCE ANCHOR THAT IS REMOVABLE IT IS AVAILABLE WITH A FINISHED HEX WASHER HEAD N 1N', 3A9', 12', SIS" AID 3A4' DIAMETERS. THE WEDGE 3OLT ANGOR IS A ONE-PIECE UNIT FORMED FROM THROUGH HARDENED STEEL WITH A FINISHED HEX MAD FORMED WITH AN INTEGRAL WASHER, A DUN. LEAD THREAD, AND A CHAMFEREDED TIP. THE CARBON STEEL VERSION OF THE ANCHOR IS ZNGPLATED FOR CORROSION RESISTANCE WITH A SUPPLEMENTAL CHROMATE RMSH N ACCOFWANCE vvfrH ASTM B 633. ,. GENERAL NOTES: 1. THEM APPROVAL DOCUMENTS 03 SENT A POWER WEDGE -BOLT ANCHOR ANALYZED WITH THE PROVISION SET FOR THE ISSUANCE OF A NOTICE OF ACCEPTANCE (NOA) BY MNAM"MOE COUNTY PRODUCT CONTROL DIVISION FOR THE HIGH VmOCITY HURRICANE ZONE (HVL¢) OF THE FLORIDA BUILDING CODE 204 WITH 2005 SUPPLEAENT. 2 ANCHOR INSTALLATION SHALL BE MADE N ACCORDANCE WITH THE MANUFACTURE'S PUBLISHED INSTALLATION INSTRUCTIONS ' AND TMS MAMFDADE COUNTY BCCO NOTICE OF ACCEPTACE. THE W XE•43OLT ANCHOR HOLE MUST BE DRILLED USING A SPECIAL MATCHED TOLERANCE WEDGE -611'. TO INSTALL THE ANCHOR PRESS THE CHAMFERED TP OF THE ANCHOR THROUGH ' THE FIXTURE INTO THE HOLE. AND TIGHTEN R USING A SOCKET WRENCH OR IMPACT WRENCH. AS THE ANCHOR IS TIGHTENED INTO THE HOLE. THE REVERSE PARABOLIC DUAL LEAD THREADS UNDERCUT THE WALL OF THE HOLE. THE DUAL LEAD THREAD IS / FORMED WITH A HIGH HELIX ANGLE FOR FAST ENTRY AND ADVANCING. A SPECIALLY DESIGNED RELIEF THREAD FORMED IN THE / BODY OF THE ANCHOR ALLOWS EASY TIGHTENING. FOR EASE OF IDENTIFICATION AFTER INSTALLATICK THE HEAD OF THE ' ANCHOR S STAMPED WITH BOTH THE DIAMETER AND LENGTH. ALLOWABLE TENSION AND SHEAR VALUES ARE NOTED IN TABLE 1. 3. NO INCREASE IN ALLOWABLE STRESS HAS SEEN USED IN THE DESIGN OF THIS PRODUCT. 4. THESE APPROVAL DOCUMENTSENTS ARE GENERIC AND DO NOT INCLUDE NFCMMATICNI FOR SITE-SPECIFIC APPLICATION 5. USE OF THESE APPROVAL DOCUMENTS SHALL COMPLY WITH CHAPTER Bt 615-23 OF THE FLORIDA ADMINSTRATIVE CODE 6. ANY MODIFICATIONS OR ADDITIONS TO THESE APPROVAL DOCUMENTS WILL VOID THE APPROVAL DOCUMENTS. / TABLE ft 'l I Soadm INId EdamDlstaRhHx. WEDGE -BOLT ANCHOR - Allow" Loads. SPACOM KTVEENN MCM -IOM 12d X 4d / 0.50 rx Anchor si2e r Em Iml 2000 psi Concrete 30000 Concrete 4000 psi Concrete 5000 Psi Concrete 6000 psi Concrete Depth Tension Shear Tension Shear Tension Shear Tension Shear Tension Shear h„) (Pounds) (Pounds) (pounds) (pounds) (Pa+xls) (Pounds) (Pounds) (Founds) (pounds) (Pounds) 3d 1 I80 . 260. 260 ' 390 • 335 520 375 360 415 600 1/4 1- 1/2 360, WD, 450 550 . 535 590 580 590 620 625 2 600 950. 795 - 550 985 SSD 1,115 640 1245 730 2-1/2 880 550 1,025 • 550 IA65 550 1,240 640 1,315 730 1- 1/2 475 645 555 1,010 630 IA70 695 1,440 760 1 1,710 2 750 1,110 665 1490 980 1,270 1440 1,490 1,300 L710 3/8 2-1/2. 1,025 1,370 leo 1,370 1,330 1,370 1,585 L540 IAW 1,710 3 1,450 1,425 L695 1,455 1,935 1,480 21203 1"3 2,475 1,710 3-1/2 ' L873 1,475 2205 L535 2,535 1. 5% 2,825 L6W 3J10 1,710 2 , 715 L430 850 1,570, 995 1,705 Logo 1,945 11195 2J85 2-1/2 1,025 L670 1,165 1,775 1,30 1,875 1,460 elm 1,620 2270 1/2 3 L480 L790 1,715 1,945 11950 2,095 2J50 U85 2,345 2,270 3-1/ 2 1,515 2,165 1,820 2,220 21120 2,270 2,550 2,335 2,975 2,400 4 IAM 2,165 21525 2220 31155 2,270 3,155 2,335 3,155 2AW 1 2-1/2 855 1,800 I'm 2255 4180 21705 1,455 3,030 1,725 3,3W 5/8 3 IJ40 2,325 IA95 21690 1,845 3A55 ZA45 3,305 2,240 3,950 4 2,060 3,145 21625 3,420 31190 3,690 3,385 3,835 3,580 3,980 5 3,325 3,750 3,940 4,010 4,555 4,270 4,885 4,355 5,215 4,440 1 3 LOBO 3A05 I= 3,420 11620 3,635 1,900 4,265 2,175 4,695 3/4 4 1,780 3AW 2,410 4,590 3=5 5,550 3,270 51630 3,505 5,705 5 2,835 41690 I 3295 5,400 3,755 61110 4,305 6,150 4,850 6.190 6 1 3,885 5,7454180 6210 4,473 6,670 1 5,355 61670 6,190 61670 1- Allowable Loads ore based on UM"Kb Load divided by a 4: 1 safe factor. 2- Spacing and edge distance shall be in accordance with Table No. a w 0 WEDGE -BOLT ANCHOR B HD 1,2 J , WAS "B" 8 3 O A= LENGTH B=DIAMETER TABLE No. 2 WEDGE4WT ANOHOR - Soadm INId EdamDlstaRhHx. DISTANCE FOR FULL ANCHOR DISTANCE FOR REDUCED ANCHOR REDUCTD]N CAPACITY (Crlied Distance) H CAPACITY (Minirtsxn Distance)1 FACTORS SPACOM KTVEENN MCM -IOM 12d X 4d / 0.50 rx SPACOEG X7VEM NOW - WM ' 12d " 4d 0.75 ^' EDM DISTANCE - TENSA ed 3d 0.70 EDGE DISTAHM - RM 12d >I 3d 0.15 1- The listed values aro the minimum distances required to obtain the bad values Rated in Table No. 1. / / d' equals Anchor Diameter. When adjacent anchors are different sizes or embedments, use largest value of 'd', 2- The fisted values are the minimun distances at which the anchor can be set, when load values aro adjusted oppnopr5ately. 3- Load values in the tables are rm*Upkd by the reduction factor when anchom are installed at the minimum distamsoliMedo*wr ilterpolatlownoy*a and f*%pocing or edge distances between thecriticalandminimumdistmm3. Multiple / shell be ccokubbd separctehyr and analt5plkd0u 0(mora than one spacing or edge diatonoe / TBODUCT RRNNWwII s mavlynq wH) tAe Fu. C_ owwBoDde e• s N -D J /O eCt hrirlw P 0000 0000 0000.. 0000.. 0000.. 0000 0000.. 0000 . 0000. 0000 0000 0000.6 000 M 0 ... . 00000.. 0000. 0.0. . 0000.. 0000 f2 0 P2 E P1 f1 REVISIONS BY Cesar I. Castilllo P. E. POST EMBEDMENT DETAIL Consulting Engineer - Fl. 68447 10500 Waves Way, Parkland, FL 33076 REVISIONS BY Ph: 954-803-8968 - cesorcostillopabon@gmail.com