Loading...
ELC-19-507Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: Location Address Parcel Number 11300 N MIAMI AVE R. KIRK LANDON STUDE, Miami 1121360000040 Shores FL 33168 Contacts Permit NO.: ELC-03-19-517 Permit Type: Electrical - Commercial Work Clossi roWn. Aitecation Pett as: Approved Expiration: 09/03/2019 Inspection Requests: Description: INSTALL (4) 8FT SECTIONS OF TRACK LIGHTING; Valuation: $ 3,600.00 305 76 4949DISCONNECTPOWER/DATE WITHIN MILLWORK; NEW QUADS FOR POWER AND DATA DROPS WITH IN NEW MILLWORK; Total Sq Feet: 0.00 DUPLEX ON COLUMN FOR COMPUTER TABLES. j Fees BARRY UNIVERSITY INC Owner BARRY UNIVERSITY 11300 NE 2 AVE, MIAMI SHORES, FL 331616628 LG4 INC Contractor LOUIS WINTER GARTNER 7 EASTLAND LN, PALM COAST, FL 32164 Business: 9546815866 50.00 CCF 2.40 DBPR Fee Inspection Requests: Description: INSTALL (4) 8FT SECTIONS OF TRACK LIGHTING; Valuation: $ 3,600.00 305 76 4949DISCONNECTPOWER/DATE WITHIN MILLWORK; NEW QUADS FOR POWER AND DATA DROPS WITH IN NEW MILLWORK; Total Sq Feet: 0.00 DUPLEX ON COLUMN FOR COMPUTER TABLES. j Fees Amount Application Fee - Other 50.00 CCF 2.40 DBPR Fee 2.00 DCA Fee 2.00 Education Surcharge 0.80 Permit Fee 58.00 Scanning Fee 9.00 Technology Fee 2.70 Total: 126.90 Payments Date Paid Amt Paid Total Fees 126.90 Credit Card 03/13/2019 $76.90 Credit Card 03/07/2019 $50.00 Amount Due: 0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFID VIT- I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regul ing const d zoning. Futhermore, I authorize the above named contractor to do the work stated. 4ZI 9' oriz Sig a ner / Applicant / Contractor / Agent Date arch 13, 2019 Page 2 of 2 BUILDING PERMIT APPLICATION Miami Shores Village RECEIVED LBuildingDepartmentMRo7zoi9 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY: Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ^ FBC M4 Master Permit No. 3 V I Sub Permit No. BUILDING Q ELECTRIC ROOFING REVISION EXTENSION RENEWAL PLUMBING [:]MECHANICAL PUBLIC WORKS CHANGE OF CANCELLATION SHOP CONTRACTOR DRAWINGS JOB ADDRESS: Barry University Bookstore - 11300 N. Miami, R. Kirk Landon Student Center, City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO _ Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Barry University Phone#: City: Miami Shores Tenant/Lessee.Name: Follett Email: mambrose@folleft.com CONTRACTOR: Company Name: LG4, Inc. Address: 7 Eastland Ln City: Palm Coast Qualifier Name State: Florida Zip: 33138 Phone#: 708-884-2108 State: Florida 6 u"t (tel , C-,r-fy.&Y- one#: 954-681-5866 Zip: 32164 one#: `35- S_966 State Certification or Registration #: C i 3 00 6 9'4,,3 Certificate of Competency #: DESIGNER: Architect/Engineer: hone#: Address: City: State: Zip: Value of Work for this Permit: $ 3,600.00 Square/Linear Footage of Work: 5,759 Sq' Type of Work: Addition 0 Alteration New Repair/Replace Demolition Description of work: Install (4) Elft sections of track lighting; disconnect power/data within Millwork; new quads for power and data drops Win new Millwork; duplex on column for computer tables. Specify color of color thru tile: Submittal Fee $ 0 3 Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Structural Reviews $ Revised02/24/2014) Training/Education Fee $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ Ir BoAding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address Zip City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days a r the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection feeMill be charged. J OWNER orAGENT The foregoingo11regoing instrument was acknowledged before me this day of MALL , 20 (9 , by QA 9A J VW h 0 A U who is personally known to me or who has produced identification and who did take an oath. NOTARY Print: Seal: ;r; JEFFRYJ.YAO Conrnisabn Ie GQ?a9918 APPROVED BY Revised02/24/2014) as all Signature The foregoing instrument was acknowledged before me this 1'4dayof&r6-11 20 / , by Le U+t w , fi+c+/ who is personally known to PL iviviL U, C Nsb me or whoh s produced # (3 - S39 -?3 - 332 0 as identification and who did take an oath. NOTARY I GG 249910 AD A, Eeaid dWNovember 12,2022 Ti uTrgtFalnkwranoeE00,'i85.1019 3111 111 Plans Examiner Structural Review Zoning Clerk NIV DATE: 03.07.19 TO: V&O 766E ds Print 8275 S. Eastern Ave Las Vegas, NV 89123 ATTN: rKRITWilson SENT VIA: Drop Off TRANSMITTAL Barry University Facilities Management 11600 NE 2nd Avenue Suite #15 Miami, Florida 33161 Telephone 305) 899-3785 Facsimile 305)899-3794 www.barry.edu REF: Landon - Bookstore Update No. DATE No. COPIES DESCRIPTION 1 03.07.19 1 1 -Signed MSV - Electric Permit App - Landon - Bookstore - Update Received by: Print Date COMMENTS: cc: SENT BY: Jeff Yao Construction Manager ESNs f'iOtt 7PERMIT REVIEW CRITERIA 1 1 f • IIAMI SH p d OR104` PERMIT ADDRESS: 11300 N MIAMI AVE, R. KIRK LANDON STUDE PARCEL: 1121360000040 Miami Shores, FL 33168 APPLICATION DATE: 03/07/2019 SQUARE FEET: 0.00 DESCRIPTION: INSTALL (4) 8FT SECTIONS OF TRACK LIGHTING; EXPIRATION DATE: 09/03/2019 VALUATION: $3,600.00 DISCONNECT POWER/DATE WITHIN MILLWORK; NE QUADS FOR POWER AND DATA DROPS WITH IN NE MILLWORK; DUPLEX ON COLUMN FOR COMPUTER TABLES. CONTACTS Contractor Owner NAME COMPANY LOUIS WINTER GARTNER LG4 INC LOUIS WINTER GARTNER LG4 INC BARRY UNIVERSITY BARRY UNIVERSITY INC ADDRESS 7 EASTLAND LN PALM COAST, FL 32164 7 EASTLAND LN PALM COAST, FL 32164 11300 NE 2 AVE MIAMI SHORES, FL 33161 REVIEW ITEM STATUS REVIEWER Electrical v.1 Requires Re -submit CARLOS SOSA email: EL@MSVFL.GOV Comments: 3/8/19 Need plan wn: w cation, wires, breal9ers and conduit size. Circuit # m: ®® o»a March 08, 2019 10050 NE 2 Ave Miami Shores FL 33138 Page 1 of 1 4 0 N ELECTRICAL PIAN m PLAN NORTH RECEIVED FKIFRAI KI(ITF ELECTRICAL, DATA, AND TELECOM DRAWINGS ARE DE51GN INTENT ONLY. IT 15 THE RESPONSIBILITY OF EACH 5UB-CONTRACTOR TO DETERMINE BEST METHODS PER CODE AND CONDITIONS. ELECTRICAL NOTE5 PRIOR TO COMENCING WITH ANY WORK, THE ELECTRICAL 51 -113 -CONTRACTOR WILL OBTAIN ALL PERMITS AND REQUIREMENTS THROUGH THE LOCAL MUNICIPALITY (UNLESS OTHERWISE DIRECTED). THE ELECTRICAL 5UB-CONTRACTOR 15 RESPONSIBLE FOR SCHEDULING INSPECTIONS AND SECURING REQUIRED ELECTRICAL INSPECTION SIGN -OFFS AFTER THE WORK HAS BEEN COMPLETED. ELECTRICAL DRAWINGS ARE FOR DESIGN INTENT ONLY; THEY ARE PROVIDED TO SHOW LOCATIONS AND QUANTITY OF DEVICES. IT 15 THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR (OR ENGINEER) TO DETERMINE CIRCUIT LOADS AND ADJUST AS NEEDED. NEW CIRCUITS MAY BE REQUIRED IN SOME CASES. APPLIANCES SUCH AS COOLERS, ICE CREAM FREEZERS. MICROWAVE OVENS, ETC. SHOULD HAVE MINIMUM OF ONE 20 AMP CIRCUIT PER APPLIANCE. ALL ELECTRICAL OUTLETS AND DATA J -BOXES AT MILLWORK COUNTERS ARE TO BE MOUNTED TO THE INSIDE BACK PANEL OF THE MILLWORK, JUST UNDER THE COUNTERTOP. POWER E DATA FOR NEW FOLLETT MILLWORK 15 TYPICALLY FED FROM A WALL OR COLUMN, WITH FLEXIBLE CONDUIT TYPICALLY RUN THROUGH THE MILLWORK. THE FOLLETT POS SERVER (PCI CABINET) REQUIRES TWO DEDICATED 20AMP CIRCUITS WITH A CLEAN GROUND. THESE DEVICES ARE TO BE MOUNTED AT G -O" AFF UNLESS OTHERWISE NOTED ON PIAN. JUNCTION BOX(E5) WITH EMPTY CONDUIT STUBBED ABOVE FINISHED CEILING E PULL -STRING TO BE MOUNTED AT G-0' AFF ADJACENT TO POWER FOR DATA AND TELEPHONE CABLE. ALL FOLLETT DATA HOME RUNS TO THIS LOCATION. DATA NOTES THE FOLLETT P05 SERVER (PC[ CABINET) 15 TYPICALLY COMPRISED OF A FLOOR STANDING LOCKABLE CABINET ON CASTERS HOUSING THE PATCH PANEL(S), NETGEAR(5), ROUTEW5), SERVER, MONITOR, AND KEYBOARD. ALL FOLLETT DATA CABLING HOME RUNS TO THIS LOCATION. THE P05 5ERVER/PCI CABINET 15 TYPICALLY LOCATED IN THE STORAGE ROOM. REFER TO "DETAIL I " FOR PCI CABINET ELEVATION AND "DETAIL 4" ON THIS SHEET TO VERIFY COMPONENT CONNECTIONS. DATA JACK SHOULD BE INSTALLED ON THE WALL NEAR THE SERVER (Qa 0-0' FOR THE MOOD MUSIC SYSTEM. CRITICAL NOTE: THE FOLLETT DATA SYSTEM MUST BE PCI COMPLIANT. ALL FOLLETT DATA CABLING MUST HOME RUN FROM THE JACK TO THE PATCH PANEL AT THE FOLLETT POS 5ERVER/PCI CABINET. J J -BOX FOR POWER DATA CONDUIT FINISHED CEILING FINISHED FLOOR. 3" MAXIMUM WIDTH STUB OUT I'46" AFF CODED ELECTRICAL -DATA -TELECOM NOTES GENERAL NOTES FOLLET75 GC WILL 5UB-CONTRACT ALL ELECTRICAL WORK TO AN ELECTRICAL CONTRACTOR LICENSED IN THE JURISDICTION WHERE THE WORK IS BEING COMPLETED. ALL DEVICES SHALL BE MOUNTED AT STANDARD HEIGHT ABOVE FINISHED FLOOR UNLESS OTHERWISE SPECIFIED. DATA CONTRACTOR TO DISCONNECT FROM PATCH PANEL AND REMOVE ANY ABANDONED FOLLETT DATA CABLE DURING RENOVATION. ALL FOLLETT DATA LINES WILL HOME RUN DIRECTLY TO THE FOLLETT PCI CABINET. ALL FOLLETT DATA CABLES HOME RUN TO FOLLETT POS SERVER/PCI CABINET LOCATION. In 1 EXISTING PCI CABINET / SERVER TO REMAIN 11 FOLLETT GC/EC TO INSTALL J -BOX ABOVE FINISHED CEILING WITH (1) 20AMP I I OV CIRCUIT WITH 3/4" CONDUIT IN WALL, STUBBED OUT AT I'-6" AFF. FOLLETT GC/EC TO INSTALL (1) EMPTY 3/4" DATA CONDUIT IN WALL W/ PULL STRING STUBBED OUT HERE a@ P-6" AFF AND STUBBED ABOVE FINISHED CEILING SEE DETAIL" 1"5HEETAG. I FORCLARIFICATION. POLLETT GC/EC TO RUN FLED( FOR POWER AND EMPTY FLEX FOR DATA FROM STUBOUTS, THROUGH FOLLETT MILLWORK, INTO THE BASE OF THE CASHWRAP UNIT. SCHOOL'S GGEC TO INSTALL (1) QUAD RECEPTACLE AND 1) EMPTY DATA J -BOX W/ PULL STRING, MOUNTED INTO THE BASE OF THE CABINET. NOTE: WORKSTATIONS DRAW APPROX, 4 AMPS PER • STATION. MAX 4 STATIONS PER 20AMP CIRC4T • • FOLLETT DATA CONTRACTOR TO PULL CABLE ANj) TERMINATE (1) FOLLETT DATA LINE. • • • • FOLLETT GC/EC TO INSTALL (1) QUAD WALL O TLE • P-6" AFF. 0000 FOLLETT GC/EC TO INSTALL DATA J -BOX AT P --U" AFF.j. W(I) 3/4" CONDUIT ABOVE FIN15HED CEILING d • • PULL -STRING. • • • • • • FOLLETT DATA CONTRACTOR TO PULL AND TE"IN&P (2) FOLLETT DATA LINE AND (1) VOICE LINE. 000009 FOLLETT GC TO INSTALL J -BOX AT I'-6" AFF tM • DEDICATED 20 AMP I I OV CIRCUIT. SCHOOL GC TO INSTALL DATA J -BOX ATI'-6'FF • • • W/PULL-STRING STUBBED ABOVE FINISHED CEIYING. • FOLLETT GC/EC TO RUN FLEXIBLE CONDUIT FROM J -BOXES FOR POWER AND DATA INTO MILLWORK. INSTALL (1) QUAD OUTLET AND (1) DATA J -BOX, MOUNTED TO BACK PANEL OF MILLWORK JUST UNDER COUNTERTOP. FOLLETT DATA CONTRACTOR TO PULL AND TERMINATE (2) FOLLETT DATA LINES b (1) VOICE LINE. NOTE: WORKSTATIONS DRAW APPROX. 4 AMPS PER STATION. MAX 4 5TATION5 PER 20 AMP CIRCUIT, FOLLETT GC TO INSTALL ()) 20 AMP/ I I OV DUPLEX FOR COMPUTER DISPLAY Q P-6" AFF FOLLETT GC TO INSTALL RUN 20 AMP CIRCUIT ABOVE CEILING FOR TRACK LIGHTING. FL.-:-, 3- 3 WEarBROOK C(7PPORATt CENW16 44ir 200 WE5TCMESTER, IL 60154 PMON4 A00••.3244506 ANY ATIiyp,oM PLAN5 WILLRE UIRE SUBM Ind WRITTEN NOTIFICATION TO, AND AMOVAL 56 FOLIiiT DE9I•N(1W6gNENT. I I• ELE:.T:'-,ICAL EW o E w z PFR VED — DATE 3IlL I ° 6. o o CA5HWRAP 5TU8 OUT SCALE: NT5 -- I ELECTRICAL LEGEND II M (N)M M) (E) EXISTING / (N) NEW/ (R1 RELOCATED / (D) DEMO m JUNCTION BOX 9 QUAD OUTLET DUPLEX OUTLET TELEPHONE / DATA DATA (SEE KEY NOTES FOR TYPE OF DATA LINE) p VOICE/ FAX/(SEE KEY NOTES FOR TYPE OF LINE) LIGHT SWITCH 4 FIRE ALARM PULL STATION W FIRE ALARM STROBE s FIRE ALARM HORN/5TROBE N CLG MTD EXIT SIGN 9) WALL MTD EXIT SIGN m THERMOSTAT a K O v- w wFU-M zM z2to QroL) =5 —1 Ln 4t 0 D Z O Z Ug¢_ rte/ m °C W J W DATE: 10-30-18 z A6.0 N 0 r' 2'-0• 0 N SIGHTING PLAN i11 PLAN NORTH CODED LIGHTING NOTES ELECTRICIAN TO VERIFY CIRCUIT CAPACITY LAMPS FOR SPOT AND PENDANT LIGHTING DRAW 10 WATTS PER FIXTURE. ALL LIGHTS ARE SUPPLIED BY AND INSTALLED BY FOLLE175 EC/GC UNLE55 NOTED OTHERWISE. s f GC/EC TO INSTALL 8' OF TRACK AND (G) SPOT LIGHTS TO BE PURCHASED BY FOLLETT0IFOLLETT CONTRACTOR. TRACK FOR SPOT LIGHTS FOR WINDOW DISPLAYS: MOUNTED AS TIGHT TO STOREFRONT AS POSSIBLE. USE LYTE5PAN POWERTRIP KIT #6099 AND POWERTRIP PLUG-IN BREAKER #PLD 120 ON EACH TRACTC"I.• • s • a s • 3 15TE ORATE CEN ER, I 200 WE5TCFj5TER,IL OI54 PHCWE: 80J,12 4506 ANY D"ATI(VI'KOM F AN5 WI I, REQUIRE 5UBMITTE'b WRITTEN NO-ViCATIOTO, AND APF"' Lm DE%GN D A ENT. a 27' •• f 2 • a a o o s a 0 Z a a m UI O a o_ Z WG g Nzu— rZmw mtaii u Z me-ZOo0 ELECTRICAL RE uj 8 Z N =, DATES lL zm Z APPROVED a U m U Q DATE: Io -3o-18 A7.0 z N