CC-19-837Chris Smeeton
csmeetOggMalt GOT
Permit Expediting
instruction
Services, Inc.
Mobile. 954-448-1423 kf
cG CA=1 9-83
V
Certificate of Completion
Miami Shores Village
10050 N. E. 2nd Ave, Miami Shores, Florida 33138
Tel: 305-795-2204 Fax: 305-756-8972
Building Inspection Department
This certificate issued pursuant to the requirements of the Florida Building Code 106.1.2 certifying that at the time of issuance this
structure was in compliance with the various ordinances of the jurisdiction regulating building construction or use. For the following:
Description: 9640 NE 2 AVE
BUILD NEW 501 X 12'H WALL TO "BOX -IN" EXISTING TELLER LINE. ALL NEW CARPET AND PAINT IN ALL CUSTOMER
FACING AREAS THROUGHOUT. REMOVE AHD BOX AND EXTERIOR CANOPY, FABRICATE WALL -IN BOX FOR BOOTH
AREA, TRENCH FOR NEW FLOOR BOXES AND POWER WHERE NEEDED.
Permit Type
Owner
Subdivision/Project
Construction Type
Square Footage
Location
9636 NE 2ND AVE
Miami Shores, FL 33138
Building (Commercial)
Palazzo Leoni Inc.
V -B
2,150.00
Bldg. Permit No. CC -04-19-837
Contractor VERICON CONSTRUCTION COMPANY LLC
Date Issued 06/25/2019
Occupancy B - 44 OCCUPANTS
Type
Flood Zone X
If the building is located in a special flood hazard area documentation of the as -built lowest floor
elevation or lowest horizontal structural member has been provided and is retained in the records of
Miami Shores Village.
This certificate issued pursuant to the requirements of the Florida Building Code certifying that at the
time of issuance this structure was in compliance with the various ordinances of the jurisdiction
regulating building construction or use.
Building Officials Approval Ismael Naranjo, CBO
Miami Shores Village
Building Department
10050 NE 2 Ave
Miami Shores FL 33138
Permit Na'CC-04-19-837•.
T: Bung (Coriercrai)r3
Wo ciass: Alt@ratlOti'<
i'ei'o*,,Sif3tiL
issue Date: 6/13/2019 Expires: 12/10/2019
INSPECTION REQUESTS: (305)762-4949 or log on at https://bldg.msvfl.gov/energov_prod/Selfservice
Requests must be received by 3:30pm POST ON SITE
WORK IS ALLOWED: MONDAY THROUGH FRIDAY, 8:OOAM-7:00PM
1132060132500SATURDAY8:OOAM - 6:OOPM.
NO WORK IS ALLOWED ON SUNDAY OR HOLIDAYS
BUILDING AND ROOFING INSPECTIONS ARE DONE MONDAY THROUGH FRIDAY.
NO INSPECTION WILL BE MADE UNLESS THE PERMIT CARD IS DISPLAYED AND HAS BEEN APPROVED . PLANS ARE
READILY AVAILABLE. IT IS THE PERMITAPPLICANTS RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND
EXPOSED FOR INSPECTION PURPOSES. NEITHER THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR
EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL REQUIRED TO ALLOW INSPECTION .
Owner's Name: Palazzo Leoni Inc. Owner's Phone:
Job Address: 9636 NE 2ND AVE Total Square Feet: 2,150
Miami Shores, FL 33138
rota) Job Valuation: $ 113,000.00
Contractor(s) Phone Address
VERICON CONSTRUCTION COMPANY L (954)850-7199 6555 POWERLINE RD 108, FT. LAUDERDALE, FL 33309
Description: BUILD NEW 501 X 12'H WALL TO "BOX -IN" EXISTING TELLER LINE. ALL NEW CARPET AND PAINT IN F
CUSTOMER FACING AREAS THROUGHOUT. REMOVE AHD BOX AND EXTERIOR CANOPY, FABRICATE WALL -IN BC
FOR BOOTH AREA, TRENCH FOR NEW FLOOR BOXES AND POWER WHERE NEEDED.
fivit-41a
iaLa :tw.
yr
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED
AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF
COMMENCEMENT.
Page 1 of 1
INSPECTION RECORD
STRUCTURAL
INSPECTION DATE INSP
Foundation
Stemwall
Slab
Gr
Columns (1st Lift)
Columns (2nd Lift)
Tie Beam
Truss/Rafters
Roof Sheathing
Bucks
Interior Framing /
Insulation
Ar
Ceiling Grid
Drywall
Firewall
Wire Lath
Pool Steel
Pool Deck
Final Pool
Final Fence
Screen Enclosure
Driveway
Driveway Base
Tin Cap
In -Progress
Roof Installation
Roofing Final
Shutters Attachment
Final Shutters
Rails and Guardrails
ADA compliance
AV
DOCUM 46
Soil Bearing Cert
Soil Treatment Cert
Floor Elevation Survey
Reinf Unit Mas Cert
Insulation Certificate
Spot Survey
Final Survey
Truss Certification
STRUCTURAL COMMENTS
WINDOWSDOORS
INSPECTION DATE INSP
Attachment
WORKSPUBLIC
INSPECTION DATE INSP
Excavation
MIMI
ELECTRICAL
INSPECTION DATE INSP
Temporary Pole
30 Day Temporary
Pool Bonding
Pool Deck Bonding
Pool Wet Niche
Underground
Footer Ground
Slab
Wall Rough
Ceiling Rough
Rough
Telephone Rough
6 i9 15
Telephone Final
TV Rough
TV Final
Cable Rough
Cable Final
Intercom Rough
Intercom Final
Alarm Rough
Alarm Final
Fire Alarm Rough
Fire Alarm Final
Service
WOELECTRICOALka NTS
INSPECTION DATE INSP
Final Sprinkler
Final Alarm
PLUMBING i
INSPECTION I DATE I INSP
Rough
Water Service
2nd Rough
Top Out
Fire Sprinklers
Septic Tank
Sewer Hook-up
Roof Drains
Gas
LP Tank
Well
Lawn Sprinklers
Main Drain
Pool Piping
Backflow Preventor
Interceptor
Catch Basins
Condensate Drains
HRS Final
IN EL --
PLUMBING COMMENTS
INSPECTION DATE INSP
Underground Pipe
Rough
Ventilation Rough
Hood Rough
Pressure Test
Final Hood
Final Ventilation
Final Pool Heater
Final Vacuum
MECHANICAL COMMENTS
Miami shores Village
ri A Building Department
Permit: D "I1l 83 10050 N.E.2nd Avenue
Miami Shores Florida 33138
E-mail:16tn m, n wr, k*oh VQ.r 1 con b1j, Id s oG,
l'el: (305) 795.2204
Phone: S S ? , — Fax: (305) 756.8972
I
CERTIFICATE OF OCCUPANCY/COMPLETION
CHECK LIST
Building permit card.
Surveys (2 copies) Final as built - Required Items: Elevations of buildings showing all intended
setbacks from property lines and other existing structures, Ingress+ Egress, required parking
spaces, Wheel stops, stripping, and all paving to exterior.
Certificate of Elevation — (Sealed by surveyor). Expiration date required on the form.
Certificate of Insulation.
Certificate of Soil Treatment (Final treatment -original)\
CHAPTER 2913-5 TERMITE PROTECTION: "This Building has received a complete treatment
for the prevention of subterranean termites. Treatment is in accordance with the rules and
law as established by the Florida Department of Agriculture and Consumer Services."
Health Department Approval Letter (On septic or private water).
Note: If the house is on septic tank, approval letter is required from Health Dpt.
Soil Compaction Letter (Density report is required)
Final certification letter from the Engineer/Architect (on masonry, trusses, special structure, etc)
Backflow preventor certificate (Required on commercial projects only)
Declaration of use. (Recorded in Miami -Dade Clerk of Courts)
PLEASE NOTE THAT THE SAME ITEMS ARE REQUIRED FOR TEMPORARY CO
Emergency CO (Without 24 Hrs Processing) Additional fee is $80.00.
Temporary CO (Up to 90 days max) $75.00.
Residential CO $150.00
Residential CC $50.00
Commercial CO and CC $200.00